Intesis ME-AC-KNX-1i ME AC interface, 4 binary inputs

ME AC interface, 4 binary inputs ME-AC-KNX-1i

Intesis · Order number ME-AC-KNX-1i · Communication › Interfaces › Mitsubishi Electric Air Conditioning Interfaces

Download .knxprod 0116 MEACKNX1i T16V21 2.1 · 148 KB

Product

ManufacturerIntesis
Product nameME AC interface, 4 binary inputs
Order numberME-AC-KNX-1i
HardwareME AC Interface
MediumTwisted Pair
Bus current (mA)6
Rail mountedNo
RegistrationCertified · 2012-11-28
Languageses-ES, en-US
Catalog entryM-0077_H-ME.2DAC.2DKNX.2D1i-1_HP-0016-21-10F5_CI-ME.2DAC.2DKNX.2D1i-1
Fingerprint10F5
SHA-2566bc2dd540be405e72f8b91fe14cde79f604c74b5a850553e7911cc5d94066d36
First seen2026-11-25
Markets69 markets

Application program: 0116 MEACKNX1i T16V21 2.1

Application number$0016
Version2.1
Mask versionMV-0025 (2.5)
KNX Data SecureNo
Minimum ETS version4.0
Parameters346
Group objects203
Group objects (203)
NoNameFunctionSizeDPTFlags
0Control_ On/Off [DPT_1.001 - 1bit]0-Off;1-On1 Bit1.1 switchCWT
1Control_ Mode [DPT_20.105 - 1byte]0-Auto;1-Heat;3-Cool;9-Fan;14-Dry1 Byte20.105 HVAC control modeCWT
2Control_ Mode Cool/Heat [DPT_1.100 - 1bit]0-Cool;1-Heat1 Bit1.100 heating/coolingCWT
3Control_ Mode Cool & On [DPT_5.001 - 1byte]0%-Off;0.1%-100%-On+Cool1 Byte5.1 percentage (0..100%)CWT
4Control_ Mode Heat & On [DPT_5.001 - 1byte]0%-Off;0.1%-100%-On+Heat1 Byte5.1 percentage (0..100%)CWT
5Control_ Mode Auto [DPT_1.002 - 1bit]1-Set AUTO mode1 Bit1.2 booleanCWT
6Control_ Mode Heat [DPT_1.002 - 1bit]1-Set HEAT mode1 Bit1.2 booleanCWT
7Control_ Mode Cool [DPT_1.002 - 1bit]1-Set COOL mode1 Bit1.2 booleanCWT
8Control_ Mode Fan [DPT_1.002 - 1bit]1-Set FAN mode1 Bit1.2 booleanCWT
9Control_ Mode Dry [DPT_1.002 - 1bit]1-Set DRY mode1 Bit1.2 booleanCWT
10Control_ Mode -/+ [DPT_1.007 - 1bit]0-Decrease;1-Increase1 Bit1.7 stepCW
10Control_ Mode +/- [DPT_1.008 - 1bit]0-Up;1-Down1 Bit1.8 up/downCW
11Control_ Ventilation Mode [DPT_20.xxx - 1byte]0-Auto;1-HeatEx; 2-Bypass1 ByteDPT.20CWT
12Control_ Mode Ventilation Auto [DPT_1.002 - 1bit]1-Set AUTO ventilation mode1 Bit1.2 booleanCWT
13Control_ Mode Ventilation HeatEx [DPT_1.002 - 1bit]1-Set HEATEX ventilation mode1 Bit1.2 booleanCWT
14Control_ Mode Ventilation Bypass [DPT_1.002 - 1bit]1-Set BYPASS ventilation mode1 Bit1.2 booleanCWT
15Control_ Ventilation Mode -/+ [DPT_1.007 - 1bit]0-Decrease;1-Increase1 Bit1.7 stepCW
15Control_ Ventilation Mode +/- [DPT_1.008 - 1bit]0-Up;1-Down1 Bit1.8 up/downCW
16Control_ Fan Speed / 4 Speeds [DPT_5.001 - 1byte]Thresholds: [100 x (n + 0.5) / N]%1 Byte5.1 percentage (0..100%)CWT
16Control_ Fan Speed / 3 Speeds [DPT_5.010 - 1byte] Speed values: 1,2,31 Byte5.10 counter pulses (0..255)CWT
16Control_ Fan Speed / 2 Speeds [DPT_5.001 - 1byte]Threshold: [100 x (n + 0.5) / N]%1 Byte5.1 percentage (0..100%)CWT
16Control_ Fan Speed / 2 Speeds [DPT_5.010 - 1byte]Speed values: 1,21 Byte5.10 counter pulses (0..255)CWT
16Control_ Fan Speed / 4 Speeds [DPT_5.010 - 1byte] Speed values: 1,2,3,41 Byte5.10 counter pulses (0..255)CWT
16Control_ Fan Speed / 3 Speeds [DPT_5.001 - 1byte]Thresholds: [100 x (n + 0.5) / N]%1 Byte5.1 percentage (0..100%)CWT
16Control_ Fan Speed / 5 Speeds [DPT_5.001 - 1byte]Thresholds: [100 x (n + 0.5) / N]%1 Byte5.1 percentage (0..100%)CWT
16Control_ Fan Speed / 5 Speeds [DPT_5.010 - 1byte] Speed values: 1,2,3,4,51 Byte5.10 counter pulses (0..255)CWT
17Control_ Fan Speed Man/Auto [DPT_1.002 - 1bit]0-Manual;1-Auto1 Bit1.2 booleanCWT
18Control_ Fan Speed 1 [DPT_1.002 - 1bit]1-Set Fan Speed 11 Bit1.2 booleanCWT
19Control_ Fan Speed 2 [DPT_1.002 - 1bit]1-Set Fan Speed 21 Bit1.2 booleanCWT
20Control_ Fan Speed 3 [DPT_1.002 - 1bit]1-Set Fan Speed 31 Bit1.2 booleanCWT
21Control_ Fan Speed 4 [DPT_1.002 - 1bit]1-Set Fan Speed 41 Bit1.2 booleanCWT
22Control_ Fan Speed 5 [DPT_1.002 - 1bit]1-Set Fan Speed 51 Bit1.2 booleanCWT
23Control_ Fan Speed -/+ [DPT_1.007 - 1bit]0-Decrease;1-Increase1 Bit1.7 stepCW
23Control_ Fan Speed +/- [DPT_1.008 - 1bit]0-Up;1-Down1 Bit1.8 up/downCW
24Control_ Vanes U-D / 5 Pos [DPT_5.001 - 1byte]Thresholds: [100 x (n + 0.5) / N]%1 Byte5.1 percentage (0..100%)CWT
24Control_ Vanes U-D / 5 Pos [DPT_5.010 - 1byte]Position values: 1,2,3,4,51 Byte5.10 counter pulses (0..255)CWT
24Control_ Vanes U-D / 4 Pos [DPT_5.001 - 1byte]Thresholds: [100 x (n + 0.5) / N]%1 Byte5.1 percentage (0..100%)CWT
24Control_ Vanes U-D / 4 Pos [DPT_5.010 - 1byte]Position values: 1,2,3,41 Byte5.10 counter pulses (0..255)CWT
25Control_ Vanes U-D Man/Auto [DPT_1.002 - 1bit]0-Manual;1-Auto1 Bit1.2 booleanCWT
26Control_ Vanes U-D Pos 1 [DPT_1.002 - 1bit]1-Set Position 11 Bit1.2 booleanCWT
27Control_ Vanes U-D Pos 2 [DPT_1.002 - 1bit]1-Set Position 21 Bit1.2 booleanCWT
28Control_ Vanes U-D Pos 3 [DPT_1.002 - 1bit]1-Set Position 31 Bit1.2 booleanCWT
29Control_ Vanes U-D Pos 4 [DPT_1.002 - 1bit]1-Set Position 41 Bit1.2 booleanCWT
30Control_ Vanes U-D Pos 5 [DPT_1.002 - 1bit]1-Set Position 51 Bit1.2 booleanCWT
31Control_ Vanes U-D Swing [DPT_1.002 - 1bit]0-Off;1-Swing1 Bit1.2 booleanCWT
32Control_ Vanes U-D +/- [DPT_1.008 - 1bit]0-Up;1-Down1 Bit1.8 up/downCWT
32Control_ Vanes U-D -/+ [DPT_1.007 - 1bit]0-Decrease;1-Increase1 Bit1.7 stepCWT
33Control_ Vanes L-R / 6 Pos [DPT_5.001 - 1byte]Thresholds: [100 x (n + 0.5) / N]%1 Byte5.1 percentage (0..100%)CWT
33Control_ Vanes L-R / 6 Pos [DPT_5.010 - 1byte]Position values: 1,2,3,4,5,61 Byte5.10 counter pulses (0..255)CWT
33Control_ Vanes L-R / 5 Pos [DPT_5.001 - 1byte]Thresholds: [100 x (n + 0.5) / N]%1 Byte5.1 percentage (0..100%)CWT
33Control_ Vanes L-R / 5 Pos [DPT_5.010 - 1byte]Position values: 1,2,3,4,51 Byte5.10 counter pulses (0..255)CWT
34Control_ Vanes L-R Pos 1 [DPT_1.002 - 1bit]1-Set Position 11 Bit1.2 booleanCWT
35Control_ Vanes L-R Pos 2 [DPT_1.002 - 1bit]1-Set Position 21 Bit1.2 booleanCWT
36Control_ Vanes L-R Pos 3 [DPT_1.002 - 1bit]1-Set Position 31 Bit1.2 booleanCWT
37Control_ Vanes L-R Pos 4 [DPT_1.002 - 1bit]1-Set Position 41 Bit1.2 booleanCWT
38Control_ Vanes L-R Pos 5 [DPT_1.002 - 1bit]1-Set Position 51 Bit1.2 booleanCWT
39Control_ Vanes L-R Pos 6 [DPT_1.002 - 1bit]1-Set Position 61 Bit1.2 booleanCWT
40Control_ Vanes L-R Swing [DPT_1.002 - 1bit]0-Off;1-Swing1 Bit1.2 booleanCWT
41Control_ Vanes L-R +/- [DPT_1.008 - 1bit]0-Up;1-Down1 Bit1.8 up/downCWT
41Control_ Vanes L-R +/- [DPT_1.007 - 1bit]0-Decrease;1-Increase1 Bit1.7 stepCWT
42Control_ Setpoint Temperature [DPT_9.001 - 2byte](ºC)2 Bytes9.1 temperature (°C)CWT
43Control_ Setpoint Temp -/+ [DPT_1.007 - 1bit]0-Decrease;1-Increase1 Bit1.7 stepCW
43Control_ Setpoint Temp +/- [DPT_1.008 - 1bit]0-Up;1-Down1 Bit1.8 up/downCW
44Control_ Ambient Temperature [DPT_9.001 - 2byte](ºC)2 Bytes9.1 temperature (°C)CWT
45Control_ Switch Off Timeout [DPT_1.010 - 1bit]0-Stop;1-Start1 Bit1.10 start/stopCWT
45Control_ Window Contact Status [DPT_1.009 - 1bit]0-Open;1-Closed1 Bit1.9 open/closeCWT
46Control_ Occupancy [DPT_1.018 - 1bit]0-Not Occupied;1-Occupied1 Bit1.18 occupancyCWT
47Control_ Sleep Timeout [DPT_1.010 - 1bit]0-Stop;1-Start1 Bit1.10 start/stopCWT
48Control_ Lock Remote Control [DPT_1.002 - 1bit]0-Unlocked;1-Locked1 Bit1.2 booleanCWT
49Control_ Lock Control Objects [DPT_1.002 - 1bit]0-Unlocked;1-Locked1 Bit1.2 booleanCWT
50Control_ Power Mode [DPT_1.010 - 1bit]0-Stop;1-Start1 Bit1.10 start/stopCWT
51Control_ Econo Mode [DPT_1.010 - 1bit]0-Stop;1-Start1 Bit1.10 start/stopCWT
52Control_ Additional Heat [DPT_1.010 - 1bit]0-Stop;1-Start1 Bit1.10 start/stopCWT
53Control_ Additional Cool [DPT_1.010 - 1bit]0-Stop;1-Start1 Bit1.10 start/stopCWT
54Control_ Execute Scene [DPT_17.001 - 1byte]0..4-Execute Scene 1-51 Byte17.1 scene numberCWT
54Control_ Save/Exec Scene [DPT_18.001 - 1byte]0..4-Exec1-5;128..132-Save1-51 Byte17.1 scene numberCWT
55Control_ Store Scene 1 [DPT_1.002 - 1bit]1-Store Scene 11 Bit1.2 booleanCW
56Control_ Store Scene 2 [DPT_1.002 - 1bit]1-Store Scene 21 Bit1.2 booleanCW
57Control_ Store Scene 3 [DPT_1.002 - 1bit]1-Store Scene 31 Bit1.2 booleanCW
58Control_ Store Scene 4 [DPT_1.002 - 1bit]1-Store Scene 41 Bit1.2 booleanCW
59Control_ Store Scene 5 [DPT_1.002 - 1bit]1-Store Scene 51 Bit1.2 booleanCW
60Control_ Execute Scene 1 [DPT_1.002 - 1bit]1-Execute Scene 11 Bit1.2 booleanCWT
61Control_ Execute Scene 2 [DPT_1.002 - 1bit]1-Execute Scene 21 Bit1.2 booleanCWT
62Control_ Execute Scene 3 [DPT_1.002 - 1bit]1-Execute Scene 31 Bit1.2 booleanCWT
63Control_ Execute Scene 4 [DPT_1.002 - 1bit]1-Execute Scene 41 Bit1.2 booleanCWT
64Control_ Execute Scene 5 [DPT_1.002 - 1bit]1-Execute Scene 51 Bit1.2 booleanCWT
65Control_ Disable Input 1 [DPT_1.003 - 1bit]0-Disable;1-Enable1 Bit1.3 enableCWT
65Control_ Disable Input 1 [DPT_1.002 - 1bit]0-False;1-True1 Bit1.2 booleanCWT
66Control_ Disable Input 2 [DPT_1.003 - 1bit]0-Disable;1-Enable1 Bit1.3 enableCWT
66Control_ Disable Input 2 [DPT_1.002 - 1bit]0-False;1-True1 Bit1.2 booleanCWT
67Control_ Disable Input 3 [DPT_1.002 - 1bit]0-False;1-True1 Bit1.2 booleanCWT
67Control_ Disable Input 3 [DPT_1.003 - 1bit]0-Disable;1-Enable1 Bit1.3 enableCWT
68Control_ Disable Input 4 [DPT_1.002 - 1bit]0-False;1-True1 Bit1.2 booleanCWT
68Control_ Disable Input 4 [DPT_1.003 - 1bit]0-Disable;1-Enable1 Bit1.3 enableCWT
69Status_ On/Off [DPT_1.001 - 1bit]0-Off;1-On1 Bit1.1 switchCRT
70Status_ Mode [DPT_20.105 - 1byte]0-Auto;1-Heat;3-Cool;9-Fan;14-Dry1 Byte20.105 HVAC control modeCRT
71Status_ Mode Cool/Heat [DPT_1.100 - 1bit]0-Cool;1-Heat1 Bit1.100 heating/coolingCRT
72Status_ Mode Auto [DPT_1.002 - 1bit]1-AUTO mode is active1 Bit1.2 booleanCRT
73Status_ Mode Heat [DPT_1.002 - 1bit]1-HEAT mode is active1 Bit1.2 booleanCRT
74Status_ Mode Cool [DPT_1.002 - 1bit]1-COOL mode is active1 Bit1.2 booleanCRT
75Status_ Mode Fan [DPT_1.002 - 1bit]1-FAN mode is active1 Bit1.2 booleanCRT
76Status_ Mode Dry [DPT_1.002 - 1bit]1-DRY mode is active1 Bit1.2 booleanCRT
77Status_ Mode Text [DPT_16.001 - 14byte]ASCII String14 Bytes16.1 Character String (ISO 8859-1)CRT
78Status_ Ventilation Mode [DPT_20.xxx - 1byte]0-Auto;1-HeatEx;2-Bypass1 ByteDPT.20CRT
79Status_ Ventilation Mode Auto [DPT_1.002 - 1bit]1-AUTO ventilation mode is active1 Bit1.2 booleanCRT
80Status_ Ventilation Mode HeatEx [DPT_1.002 - 1bit]1-HEATEX ventilation mode is active1 Bit1.2 booleanCRT
81Status_ Ventilation Mode Bypass [DPT_1.002 - 1bit]1-BYPASS ventilation mode is active1 Bit1.2 booleanCRT
82Status_ Ventilation Mode Text [DPT_16.001 - 14byte]ASCII String14 Bytes16.1 Character String (ISO 8859-1)CRT
83Status_ Fan Speed / 3 Speeds [DPT_5.001 - 1byte][(100 x (n/N)]%1 Byte5.1 percentage (0..100%)CRT
83Status_ Fan Speed / 3 Speeds [DPT_5.010 - 1byte]Speed Values: 1,2,31 Byte5.10 counter pulses (0..255)CRT
83Status_ Fan Speed / 2 Speeds [DPT_5.001 - 1byte][(100 x (n/N)]%1 Byte5.1 percentage (0..100%)CRT
83Status_ Fan Speed / 2 Speeds [DPT_5.010 - 1byte]Speed Values: 1,21 Byte5.10 counter pulses (0..255)CRT
83Status_ Fan Speed / 4 Speeds [DPT_5.001 - 1byte][(100 x (n/N)]%1 Byte5.1 percentage (0..100%)CRT
83Status_ Fan Speed / 4 Speeds [DPT_5.010 - 1byte]Speed Values: 1,2,3,41 Byte5.10 counter pulses (0..255)CRT
83Status_ Fan Speed / 5 Speeds [DPT_5.001 - 1byte][(100 x (n/N)]%1 Byte5.1 percentage (0..100%)CRT
83Status_ Fan Speed / 5 Speeds [DPT_5.010 - 1byte]Speed values: 1,2,3,4,51 Byte5.10 counter pulses (0..255)CRT
84Status_ Fan Speed Man/Auto [DPT_1.002 - 1bit]0-Manual;1-Auto1 Bit1.2 booleanCRT
85Status_ Fan Speed 1 [DPT_1.002 - 1bit]1-Fan in speed 11 Bit1.2 booleanCRT
86Status_ Fan Speed 2 [DPT_1.002 - 1bit]1-Fan in speed 21 Bit1.2 booleanCRT
87Status_ Fan Speed 3 [DPT_1.002 - 1bit]1-Fan in speed 31 Bit1.2 booleanCRT
88Status_ Fan Speed 4 [DPT_1.002 - 1bit]1-Fan in speed 41 Bit1.2 booleanCRT
89Status_ Fan Speed 5 [DPT_1.002 - 1bit]1-Fan in speed 51 Bit1.2 booleanCRT
90Status_ Fan Speed Text [DPT_16.001 - 14byte]ASCII String14 Bytes16.1 Character String (ISO 8859-1)CRT
91Status_ Vanes U-D / 5 pos [DPT_5.010 - 1byte][(100 x (n/N)]%1 Byte5.1 percentage (0..100%)CRT
91Status_ Vanes U-D / 5 pos [DPT_5.010 - 1byte]Position values: 1,2,3,4,51 Byte5.10 counter pulses (0..255)CRT
91Status_ Vanes U-D / 4 pos [DPT_5.001 - 1byte][(100 x (n/N)]%1 Byte5.1 percentage (0..100%)CRT
91Status_ Vanes U-D / 4 pos [DPT_5.010 - 1byte]Position values: 1,2,3,41 Byte5.10 counter pulses (0..255)CRT
92Status_ Vanes U-D Man/Auto [DPT_1.002 - 1bit]0-Manual;1-Auto1 Bit1.2 booleanCRT
93Status_ Vanes U-D Pos 1 [DPT_1.002 - 1bit]1-Vanes in Position 11 Bit1.2 booleanCRT
94Status_ Vanes U-D Pos 2 [DPT_1.002 - 1bit]1-Vanes in Position 21 Bit1.2 booleanCRT
95Status_ Vanes U-D Pos 3 [DPT_1.002 - 1bit]1-Vanes in Position 31 Bit1.2 booleanCRT
96Status_ Vanes U-D Pos 4 [DPT_1.002 - 1bit]1-Vanes in Position 41 Bit1.2 booleanCRT
97Status_ Vanes U-D Pos 5 [DPT_1.002 - 1bit]1-Vanes in Position 51 Bit1.2 booleanCRT
98Status_ Vanes U-D Swing [DPT_1.002 - 1bit]0-Off;1-Swing1 Bit1.2 booleanCRT
99Status_ Vanes U-D Text [DPT_16.001 - 14byte]ASCII String14 Bytes16.1 Character String (ISO 8859-1)CRT
100Status_ Vanes L-R / 6 pos [DPT_5.001 - 1byte][(100 x (n/N)]%1 Byte5.1 percentage (0..100%)CRT
100Status_ Vanes L-R / 6 pos [DPT_5.010 - 1byte]Position values: 1,2,3,4,5,61 Byte5.10 counter pulses (0..255)CRT
100Status_ Vanes L-R / 5 pos [DPT_5.001 - 1byte][(100 x (n/N)]%1 Byte5.1 percentage (0..100%)CRT
100Status_ Vanes L-R / 5 pos [DPT_5.010 - 1byte]Position values: 1,2,3,4,5,61 Byte5.10 counter pulses (0..255)CRT
101Status_ Vanes L-R Pos 1 [DPT_1.002 - 1bit]1-Vanes in Position 11 Bit1.2 booleanCRT
102Status_ Vanes L-R Pos 2 [DPT_1.002 - 1bit]1-Vanes in Position 21 Bit1.2 booleanCRT
103Status_ Vanes L-R Pos 3 [DPT_1.002 - 1bit]1-Vanes in Position 31 Bit1.2 booleanCRT
104Status_ Vanes L-R Pos 4 [DPT_1.002 - 1bit]1-Vanes in Position 41 Bit1.2 booleanCRT
105Status_ Vanes L-R Pos 5 [DPT_1.002 - 1bit]1-Vanes in Position 51 Bit1.2 booleanCRT
106Status_ Vanes L-R Pos 6 [DPT_1.002 - 1bit]1-Vanes in Position 61 Bit1.2 booleanCRT
107Status_ Vanes L-R Swing [DPT_1.002 - 1bit]0-Off;1-Swing1 Bit1.2 booleanCRT
108Status_ Vanes L-R Text [DPT_16.001 - 14byte]ASCII String14 Bytes16.1 Character String (ISO 8859-1)CRT
109Status_ AC Setpoint Temp [DPT_9.001 - 2byte](ºC)2 Bytes9.1 temperature (°C)CRT
110Status_ AC Return Temperature [DPT_9.001 - 2byte](ºC)2 Bytes9.1 temperature (°C)CRT
111Status_ Outdoor Temperature [DPT_9.001 - 2byte](ºC)2 Bytes9.1 temperature (°C)CRT
112Status_ Indoor Temperature [DPT_9.001 - 2byte](ºC)2 Bytes9.1 temperature (°C)CRT
113Status_ Error/Alarm [DPT_1.005 - 1bit]0-No alarm;1-Alarm1 Bit1.5 alarmCRT
114Status_ Error Code [2byte]0-No error /Any other see manual2 BytesDPT.7CRT
115Status_ Error Text Code [DPT_16.001 - 14byte]4 char ME Error;Empty-None14 Bytes16.1 Character String (ISO 8859-1)CRT
116Status_ Power Mode [DPT_1.001 - 1bit]0-Off;1-On1 Bit1.1 switchCRT
117Status_ Econo Mode [DPT_1.001 - 1bit]0-Off;1-On1 Bit1.1 switchCRT
118Status_ Additional Heat [DPT_1.001 - 1bit]0-Off;1-On1 Bit1.1 switchCRT
119Status_ Additional Cool [DPT_1.001 - 1bit]0-Off;1-On1 Bit1.1 switchCRT
120Status_ Operation Hour Counter [DPT_7.001 - 2byte]Number of operating hours2 Bytes7.1 pulsesCRT
121Status_ Current Scene [DPT_17.001 - 1byte]0..4-Scene X+1;63-No Scene1 Byte17.1 scene numberCRT
122Status_ In1 - Switching [DPT_1.001 - 1bit]0-Off;1-On1 Bit1.1 switchCRT
122Status_ In1 - Dimming - On/Off [DPT_1.001 - 1bit]0-Off;1-On1 Bit1.1 switchCRT
122Status_ In1 - Shut/Blind - Step [DPT_1.008 - 1bit]0-Step Up;1-Step Down1 Bit1.8 up/downCRT
123Status_ In1 - Dimming - Step(%) [DPT_3.007 - 4bit]Dimming step4 Bit3.7 dimming controlCRT
123Status_ In1 - Shut/Blind - Move [DPT_1.008 - 1bit]0-Move Up;1-Move Down1 Bit1.8 up/downCRT
123Status_ In1 - Value [DPT_12.001 - 4byte]4-byte unsigned value4 Bytes12.1 counter pulses (unsigned)CRT
123Status_ In1 - Value [DPT_5.010 - 1byte]1-byte unsigned value1 Byte5.10 counter pulses (0..255)CRT
123Status_ In1 - Value [DPT_8.001 - 2byte]2-byte signed value2 Bytes8.1 pulses differenceCRT
123Status_ In1 - Value [DPT_9.001 - 2byte]Temperature (ºC)2 Bytes9.1 temperature (°C)CRT
123Status_ In1 - Value [DPT_7.001 - 2byte]2-byte unsigned value2 Bytes7.1 pulsesCRT
124Status_ In2 - Switching [DPT_1.001 - 1bit]0-Off;1-On1 Bit1.1 switchCRT
124Status_ In2 - Dimming - On/Off [DPT_1.001 - 1bit]0-Off;1-On1 Bit1.1 switchCRT
124Status_ In2 - Shut/Blind - Step [DPT_1.008 - 1bit]0-Step Up;1-Step Down1 Bit1.8 up/downCRT
125Status_ In2 - Dimming - Step(%) [DPT_3.007 - 4bit]Dimming step4 Bit3.7 dimming controlCRT
125Status_ In2 - Value [DPT_7.001 - 2byte]2-byte unsigned value2 Bytes7.1 pulsesCRT
125Status_ In2 - Value [DPT_12.001 - 4byte]4-byte unsigned value4 Bytes12.1 counter pulses (unsigned)CRT
125Status_ In2 - Value [DPT_9.001 - 2byte]Temperature (ºC)2 Bytes9.1 temperature (°C)CRT
125Status_ In2 - Value [DPT_8.001 - 2byte]2-byte signed value2 Bytes8.1 pulses differenceCRT
125Status_ In2 - Value [DPT_5.010 - 1byte]1-byte unsigned value1 Byte5.10 counter pulses (0..255)CRT
125Status_ In2 - Shut/Blind - Move [DPT_1.008 - 1bit]0-Move Up;1-Move Down1 Bit1.8 up/downCRT
126Status_ In3 - Switching [DPT_1.001 - 1bit]0-Off;1-On1 Bit1.1 switchCRT
126Status_ In3 - Dimming - On/Off [DPT_1.001 - 1bit]0-Off;1-On1 Bit1.1 switchCRT
126Status_ In3 - Shut/Blind - Step [DPT_1.008 - 1bit]0-Step Up;1-Step Down1 Bit1.8 up/downCRT
127Status_ In3 - Dimming - Step(%) [DPT_3.007 - 4bit]Dimming step4 Bit3.7 dimming controlCRT
127Status_ In3 - Value [DPT_12.001 - 4byte]4-byte unsigned value4 Bytes12.1 counter pulses (unsigned)CRT
127Status_ In3 - Value [DPT_9.001 - 2byte]Temperature (ºC)2 Bytes9.1 temperature (°C)CRT
127Status_ In3 - Value [DPT_8.001 - 2byte]2-byte signed value2 Bytes8.1 pulses differenceCRT
127Status_ In3 - Value [DPT_7.001 - 2byte]2-byte unsigned value2 Bytes7.1 pulsesCRT
127Status_ In3 - Value [DPT_5.010 - 1byte]1-byte unsigned value1 Byte5.10 counter pulses (0..255)CRT
127Status_ In3 - Shut/Blind - Move [DPT_1.008 - 1bit]0-Move Up;1-Move Down1 Bit1.8 up/downCRT
128Status_ In4 - Switching [DPT_1.001 - 1bit]0-Off;1-On1 Bit1.1 switchCRT
128Status_ In4 - Dimming - On/Off [DPT_1.001 - 1bit]0-Off;1-On1 Bit1.1 switchCRT
128Status_ In4 - Shut/Blind - Step [DPT_1.008 - 1bit]0-Step Up;1-Step Down1 Bit1.8 up/downCRT
129Status_ In4 - Dimming - Step(%) [DPT_3.007 - 4bit]Dimming step4 Bit3.7 dimming controlCRT
129Status_ In4 - Value [DPT_12.001 - 4byte]4-byte unsigned value4 Bytes12.1 counter pulses (unsigned)CRT
129Status_ In4 - Value [DPT_9.001 - 2byte]Temperature (ºC)2 Bytes9.1 temperature (°C)CRT
129Status_ In4 - Value [DPT_8.001 - 2byte]2-byte signed value2 Bytes8.1 pulses differenceCRT
129Status_ In4 - Value [DPT_7.001 - 2byte]2-byte unsigned value2 Bytes7.1 pulsesCRT
129Status_ In4 - Value [DPT_5.010 - 1byte]1-byte unsigned value1 Byte5.10 counter pulses (0..255)CRT
129Status_ In4 - Shut/Blind - Move [DPT_1.008 - 1bit]0-Move Up;1-Move Down1 Bit1.8 up/downCRT
130Legacy_ Mode [Enumerated - 1byte]0-Auto;1-Heat,2-Dry,3-Fan;4-Cool1 ByteDPT.5CRT
131Legacy_ Fan Speed [Enumerated - 1byte]0 - Auto; 1..4 - speed 1..41 ByteDPT.5CRT
132Legacy_ Vanes [Enumerated - 1byte]0-Auto; 1..5-pos1..5; 6-Swing1 ByteDPT.5CRT
Parameters (233)
ParameterTypeDefault
Download latest database entry for this product and its User Manual from:texthttp://www.intesis.com
Send READs for Control_ objects on bus recovery (T & U flags must be active)listNo
> Delay before sending READs (sec)unsignedInt 0…3010
Scene to load on bus recovery / startup (needs to define vals for that scene)list(none)
Disallow control from remote controllerlistNo
> Enable comm obj "Ctrl_ Remote Lock"listNo
Enable func "Control_ Lock Control Obj"listNo
Enable func "Operating Hours Counter"listNo
Enable object "Error Code [2byte]"listNo
Enable object "Error Text Code [14byte]" (4 ASCII-char Error Code)listYes
Indoor unit has AUTO mode (see docum. for your indoor unit)listYes
Indoor unit has HEAT mode (see docum. for your indoor unit)listYes
Indoor unit has Mode FAN (see docum. for your indoor unit)listYes
Indoor unit has DRY mode (see docum. for your indoor unit)listYes
When mode is AUTO Status_ objs report actual operating status (HEAT/COOL/..)listNo
Enable "Mode Cool/Heat" objects (for Control and Status)listNo
Enable PID-Compat. Scaling Mode objects (for Control)listNo
Enable use of +/- object for ModelistNo
> DPT type for +/- Mode Objectlist0-Decrease / 1-Increase [DPT_1.007]
Enable use of bit-type Mode objects (for Control)listNo
Enable use of bit-type Mode objects (for Status)listNo
Enable use of Text object for ModelistNo
ASCII strings shown in comm object "Status_ Mode Text"text<< 14-byte string values >>
> String when mode is AUTOtextAUTO
> String when mode is HEATtextHEAT
> String when mode is COOLtextCOOL
> String when mode is FANtextFAN
> String when mode is DRYtextDRY
Enable use of Legacy_ object for Mode (compatible with old vers of XXACKNX1)listNo
Enable use of "POWERFUL" mode (AC feature)listNo
Enable use of "QUIET" mode (AC feature)listNo
Enable use of POWER modelistNo
> Action time for this mode (minutes)unsignedInt 1…18030
> Setpoint delta increase (HEAT) or decrease (COOL) (ºC)list2.0 ºC
> Fanspeed for this mode (if available)listFAN SPEED 2
Enable use of ECONOMY modelistNo
> Setpoint delta decrease (HEAT) or increase (COOL) (ºC)list2.0 ºC
> Fanspeed for this mode (if available)listFAN SPEED 1
Enable use of ADDITIONAL HEATING modelistNo
> Setpoint temp for this mode (ºC)list28.0 ºC
Enable use of ADDITIONAL COOLING modelistNo
> Setpoint temp for this mode (ºC)list19.0 ºC
Fan is accessible in Indoor unit (see docum. for your indoor unit)listYes
Available fanspeeds in Indoor Unit (see docum. for your indoor unit)unsignedInt 2…53
Indoor unit has AUTO fan speed (see docum. for your indoor unit)listNo
DPT object type for fanspeedlistScaling [DPT_5.001]
Enable use of +/- object for Fan SpeedlistNo
> DPT type for +/- Fan Speed objectlist0-Decrease / 1-Increase [DPT_1.007]
> Does +/- sequence include fan speed AUTO?listNo
> Rollover Speed at upper/lower limit (when controlling with +/- obj)listYes
Enable "Fan Speed Manual/Auto" objects (for Control and Status)listNo
Enable use of bit-type Fan Speed objects (for Control)listNo
Enable use of bit-type Fan Speed objects (for Status)listNo
Enable use of Text object for Fan SpeedlistNo
ASCII strings shown in comm object "Status_ Fan Speed Text"text<< 14-byte string values >>
> String when fan speed is AUTO (if available)textAUTO
> String when fan speed is 1textSPEED 1
> String when fan speed is 2textSPEED 2
> String when fan speed is 3textSPEED 3
> String when fan speed is 4textSPEED 4
> String when fan speed is 5textSPEED 5
Enable use of Legacy_ object for Fan (compatible with old vers of XXACKNX1)listNo
Indoor unit has U-D Vanes (see docum. for your indoor unit)listNo
Available positions in Indoor Unit (see docum. for your indoor unit)unsignedInt 4…55
Indoor unit has AUTO Vanes U-D (see docum. for your indoor unit)listNo
Indoor unit has SWING Vanes U-D (see docum. for your indoor unit)listYes
DPT object type for Vanes Up-DownlistScaling [DPT_5.001]
Enable use of +/- object for Vanes U-DlistNo
> DPT type for +/- Vanes U-D objectlist0-Decrease / 1-Increase [DPT_1.007]
> Does +/- sequence include AUTO vanes Up-Down?listNo
> Does +/- sequence include SWING vanes Up-Down?listNo
> Rollover Vanes at upper/lower limit (when controlling with +/- obj)listYes
Enable use of bit-type Vanes U-D objects (for Control)listNo
Enable use of bit-type Vanes U-D objects (for Status)listNo
Enable "Vanes U-D Man/Auto" objects (for Control and Status)listNo
Enable "Vanes U-D Swing" objects (for Control and Status)listNo
Enable use of Text object for Vanes U-DlistNo
ASCII strings shown in comm object "Status_ Vanes U-D Text"text<< 14-byte string values >>
> String when vanes U-D in AUTO (if available)textU-D AUTO
> String when vanes U-D in POS 1textU-D POS 1
> String when vanes U-D in POS 2textU-D POS 2
> String when vanes U-D in POS 3textU-D POS 3
> String when vanes U-D in POS 4textU-D POS 4
> String when vanes U-D in POS 5textU-D POS 5
> String when vanes U-D in SWINGtextU-D SWING
Enable use of Legacy_ object for Vanes (compatible with old vers of XXACKNX1)listNo
Indoor unit has L-R Vanes (see docum. for your indoor unit)listNo
Available positions in Indoor Unit (see docum. for your indoor unit)unsignedInt 5…66
Indoor unit has SWING Vanes L-R (see docum. for your indoor unit)listNo
DPT object type for Vanes Left-RightlistScaling [DPT_5.001]
Enable use of +/- object for Vanes L-RlistNo
> DPT type for +/- Vanes L-R objectlist0-Decrease / 1-Increase [DPT_1.007]
Enable use of bit-type Vanes L-R objects (for Control)listNo
Enable use of bit-type Vanes L-R objects (for Status)listNo
Enable use of Text object for Vanes L-RlistNo
ASCII strings shown in comm object "Status_ Vanes L-R Text"text<< 14-byte string values >>
> String when vanes L-R in AUTOtextL-R AUTO
> String when vanes L-R in POS 1textL-R POS 1
> String when vanes L-R in POS 2textL-R POS 2
> String when vanes L-R in POS 3textL-R POS 3
> String when vanes L-R in POS 4textL-R POS 4
> String when vanes L-R in POS 5textL-R POS 5
Periodic sending of "Status_ AC Setp" (in seconds;0=No periodic sending)unsignedInt 0…2550
Transmission of "Status_ AC Return Temp"listOnly cyclically
> "Status_ AC Return Temp" periodic sending time (in sec)unsignedInt 1…255180
Enable use of +/- obj for Setpoint TemplistNo
> DPT type for +/- Setp Temp objectlist0-Decrease / 1-Increase [DPT_1.007]
> [+/-] step sizelist1.0 ºC
Enable limits on Control_ Setpoint objlistNo
> Lower limit (ºC)list19.0 ºC
> Upper limit (ºC)list28.0 ºC
Ambient temp. ref. is provided from KNX (carefully read User Guide if enabled)listNo
Enable use of sceneslistNo
Scenes can be stored from KNX buslistNo
> Enable use of bit objects for storing scenes (from bus)listNo
Enable use of bit objects for scene executionlistNo
Scene 1 presetlistNo
> Scene 1 / Value for On-Offlist(unchanged)
> Scene 1 / Value for Modelist(unchanged)
> Scene 1 / Value for Fan Speed (if available)list(unchanged)
> Scene 1 / Value for Vanes U-D (if available)list(unchanged)
> Scene 1 / Value for Vanes L-R (if available)list(unchanged)
> Scene 1 / Value for Setpoint Templist(unchanged)
> Scene 1 / Value for Remote Locklist(unchanged)
> Scene 1 / Value for Humidifying (if available)list(unchanged)
Scene 2 presetlistNo
> Scene 2 / Value for On-Offlist(unchanged)
> Scene 2 / Value for Modelist(unchanged)
> Scene 2 / Value for Fan Speed (if available)list(unchanged)
> Scene 2 / Value for Vanes U-D (if available)list(unchanged)
> Scene 2 / Value for Vanes L-R (if available)list(unchanged)
> Scene 2 / Value for Setpoint Templist(unchanged)
> Scene 2 / Value for Remote Locklist(unchanged)
> Scene 2 / Value for Humidifying (if available)list(unchanged)
Scene 3 presetlistNo
> Scene 3 / Value for On-Offlist(unchanged)
> Scene 3 / Value for Modelist(unchanged)
> Scene 3 / Value for Fan Speed (if available)list(unchanged)
> Scene 3 / Value for Vanes U-D (if available)list(unchanged)
> Scene 3 / Value for Vanes L-R (if available)list(unchanged)
> Scene 3 / Value for Setpoint Templist(unchanged)
> Scene 3 / Value for Remote Locklist(unchanged)
> Scene 3 / Value for Humidifying (if available)list(unchanged)
Scene 4 presetlistNo
> Scene 4 / Value for On-Offlist(unchanged)
> Scene 4 / Value for Modelist(unchanged)
> Scene 4 / Value for Fan Speed (if available)list(unchanged)
> Scene 4 / Value for Vanes U-D (if available)list(unchanged)
> Scene 4 / Value for Vanes L-R (if available)list(unchanged)
> Scene 4 / Value for Setpoint Templist(unchanged)
> Scene 4 / Value for Remote Locklist(unchanged)
> Scene 4 / Value for Humidifying (if available)list(unchanged)
Scene 5 presetlistNo
> Scene 5 / Value for On-Offlist(unchanged)
> Scene 5 / Value for Modelist(unchanged)
> Scene 5 / Value for Fan Speed (if available)list(unchanged)
> Scene 5 / Value for Vanes U-D (if available)list(unchanged)
> Scene 5 / Value for Vanes L-R (if available)list(unchanged)
> Scene 5 / Value for Setpoint Templist(unchanged)
> Scene 5 / Value for Remote Locklist(unchanged)
> Scene 5 / Value for Humidifying (if available)list(unchanged)
Enable use of Open Window / Switch off timeout functionlistNo
> AC switch-off timeout (min)unsignedInt 0…3010
> DPT for Window / Switch-off timeoutlist0-Stop / 1-Start Timeout [DPT_1.010]
> Disallow On/Off operation while window is OpenlistNo
> Disallow On/Off operation while timeout is elapsedlistNo
> Reload last On/Off val once timeout is stoppedlistNo
> Reload last On/Off val once window is ClosedlistNo
Enable use of Occupancy functionlistNo
> Timeout to apply action (minutes)unsignedInt 0…18020
> Action after timeout elapsedlistSwitch-Off AC
> Temp delta decrease (HEAT) or increase (COOL) (ºC)list2.0 ºC
> Enable secondary timeoutlistNo
> Timeout to apply action (min)unsignedInt 1…18020
> Action after timeout elapsedlistSwitch-Off AC
> Temp delta dec (HEAT) or inc (COOL) (ºC)list3.0 ºC
> Disallow On/Off operation while not OccupiedlistNo
> Reload last On/Off value when OccupiedlistNo
Enable use of Sleep functionlistNo
> Sleep function switch-off timeout (minutes)unsignedInt 0…18060
Enable use of Input 1listNo
> Contact typelistNO: Normally Open
> Debounce timelist50 ms
> Disabling functionlistNo
> Reset Input when enablinglistNo
> FunctionlistSwitching
> Send telegram after bus recoverylistNo action
> Sending delay after bus recovery (seconds)unsignedInt 0…25510
> Value on raising edge (contact activated)listNo action
> Scene when contact is activated (needs to be defined)listScene 1
> Mode for short (long) operationlistToggle: On/Off (increase/decrease)
> OperationlistToggle (Up/Down)
> DPT to be sentlistDPT 5.010 (1byte)
> Value on falling edge (contact deactivated)listNo action
> Increasing steplist+ 25 %
> MethodlistStep-Move-Step
> Cyclical sendinglistNever
> Decreasing steplist- 25 %
> Short/long operation limit (x100ms)unsignedInt 1…25510
> Period for cyclical sending (seconds)unsignedInt 1…6553510
> Vanes adjustment time (x100ms)unsignedInt 1…25510
> Value on raising edge (when contact activated)unsignedInt 0…2550
> Value on raising edge (when contact activated)unsignedInt 0…655350
> Value on raising edge (when contact activated)signedInt -32768…327670
> Value on rais. edge (x0.1ºC) (when contact activated)signedInt -2730…3276250
> Value on raising edge (when contact activated)unsignedInt 0…42949672950
> Cycl. send. period in long oper. (x100ms)(0-No cyclical send.)unsignedInt 0…2550
Enable use of Input 2listNo
Enable use of Input 3listNo
Enable use of Input 4listNo
Type of unit (0-AC or 1-Lossnay)listAC unit
> String when vanes L-R in POS 6textL-R POS 6
> String when vanes L-R in SWINGtextL-R SWING
Enable use of Text object for Ventilation ModelistNo
> String when ventilation mode is AUTOtextAUTO
> String when ventilation mode is BYPASStextBYPASS
> String when ventilation mode is HEATEXtextHEATEX
> DPT type for +/- Ventilation Mode Objectlist0-Up / 1-Down [DPT_1.008]
> Does +/- sequence include vanes Left-Right SWING?listNo
Enable "Vanes L-R Swing" objects (for Control and Status)listNo
Enable use of bit-type Ventilation Mode objects (for Control)listNo
Enable use of bit-type Ventilation Mode objects (for Status)listNo
Enable use of +/- object for Ventilation ModelistNo
Available fanspeeds in Lossnay Unit (see docum for your indoor unit)unsignedInt 3…44
Fan is accessible in Lossnay unitlistNo
> Scene 1 / Value for Ventilation Modelist(unchanged)
> Scene2 / Value for Ventilation Modelist(unchanged)
> Scene 3 / Value for Ventilation Modelist(unchanged)
> Scene 4 / Value for Ventilation Modelist(unchanged)
> Scene5 / Value for Ventilation Modelist(unchanged)
> Timeout To apply Off-unit action (minutes)unsignedInt 0…18020
_actionAfterFirstTimeoutFixedlistSwitch-Off AC
Indoor unit has AUTO Vanes L-R (see docum. for your indoor unit)listNo

Version history

ApplicationApp noFingerprintFirst seenSizeFile
0116 MEACKNX1i T16V21 2.1 latest$001610F52026-11-25148 KBDownload

About this file

This is the official ETS product database for the Intesis ME AC interface, 4 binary inputs (ME-AC-KNX-1i), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Intesis

All Intesis products