Intesis HA-AC-KNX HA AC interface (multiple indoor units)

HA AC interface (multiple indoor units) HA-AC-KNX

Intesis · Order number HA-AC-KNX · Communication › Interfaces › Haier Air Conditioning Interfaces

Download .knxprod HAACKNX T29V10 (p) 1.0 · 354 KB

Product

ManufacturerIntesis
Product nameHA AC interface (multiple indoor units)
Order numberHA-AC-KNX
HardwareHA-AC-KNX
MediumTwisted Pair
Bus current (mA)20
Rail mountedNo
RegistrationCertified · 2017-09-27
Languageses-ES, en-US
Catalog entryM-0077_H-HA.2DAC.2DKNX-0_HP-102A-10-578C-002A-10-3756_CI-HA.2DAC.2DKNX-1
Fingerprint578C
SHA-2569457a33ea03bdd3a5d7586713289587871e4618d7d641465a24b35eebaddd3e8
First seen2026-11-25
Markets69 markets

Application program: HAACKNX T29V10 (p) 1.0

Application number$102A
Version1.0
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version4.0
Parameters378
Group objects3392
Group objects (3392)
NoNameFunctionSizeDPTFlags
1AC01 Control_ On/Off [DPT_1.001]0-Off;1-On1 Bit1.1 switchCW
2AC01 Control_ Operating Mode [DPT_20.102]0-Aut;1-Com;2-Stan;3-Eco;4-Pro1 Byte20.102 HVAC modeCW
3AC01 Control_ Mode [DPT_20.105]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 Byte20.105 HVAC control modeCW
4AC01 Control_ Mode Cool/Heat [DPT_1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCW
5AC01 Control_ Mode Auto [DPT_1.002]1-Set AUTO mode1 Bit1.2 booleanCW
6AC01 Control_ Mode Heat [DPT_1.002]1-Set HEAT mode1 Bit1.2 booleanCW
7AC01 Control_ Mode Cool [DPT_1.002]1-Set COOL mode1 Bit1.2 booleanCW
8AC01 Control_ Mode Fan [DPT_1.002]1-Set FAN mode1 Bit1.2 booleanCW
9AC01 Control_ Mode Dry [DPT_1.002]1-Set DRY mode1 Bit1.2 booleanCW
10AC01 Control_ Mode +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
10AC01 Control_ Mode +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
11AC01 Control_ Fan Speed [DPT_5.001]Thresholds: 50% and 83%1 Byte5.1 percentage (0..100%)CW
11AC01 Control_ Fan Speed [DPT_5.010]Speed values: 1,2,31 Byte5.10 counter pulses (0..255)CW
12AC01 Control_ Fan Speed Man/Auto [DPT_1.002]0-Manual;1-Auto1 Bit1.2 booleanCW
13AC01 Control_ Fan Speed 1 [DPT_1.002]1-Set Fan Speed 11 Bit1.2 booleanCW
14AC01 Control_ Fan Speed 2 [DPT_1.002]1-Set Fan Speed 21 Bit1.2 booleanCW
15AC01 Control_ Fan Speed 3 [DPT_1.002]1-Set Fan Speed 31 Bit1.2 booleanCW
16AC01 Control_ Fan Speed +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
16AC01 Control_ Fan Speed +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
17AC01 Control_ Setpoint Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
18AC01 Control_ Setpoint Temperature +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
18AC01 Control_ Setpoint Temperature +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
19AC01 Control_ Ambient Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
20AC01 Control_ Control Mode No Central [DPT_1.002]1-Set NO CENTRAL mode1 Bit1.2 booleanCW
21AC01 Control_ Control Mode LIFO [DPT_1.002]1-Set LIFO mode1 Bit1.2 booleanCW
22AC01 Control_ Control Mode Central [DPT_1.002]1-Set CENTRAL mode1 Bit1.2 booleanCW
23AC01 Control_ Control Mode Lock [DPT_1.002]1-Set LOCK mode1 Bit1.2 booleanCW
24AC01 Status_ On/Off [DPT_1.001]0-Off;1-On1 Bit1.1 switchCRT
25AC01 Status_ Operating Mode [DPT_20.102]0-Aut;1-Com;2-Stan;3-Eco;4-Pro1 Byte20.102 HVAC modeCRT
26AC01 Status_ Mode [DPT_20.105]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 Byte20.105 HVAC control modeCRT
27AC01 Status_ Mode Cool/Heat [DPT_1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCRT
28AC01 Status_ Mode Auto [DPT_1.002]1-AUTO mode is active1 Bit1.2 booleanCRT
29AC01 Status_ Mode Heat [DPT_1.002]1-HEAT mode is active1 Bit1.2 booleanCRT
30AC01 Status_ Mode Cool [DPT_1.002]1-COOL mode is active1 Bit1.2 booleanCRT
31AC01 Status_ Mode Fan [DPT_1.002]1-FAN mode is active1 Bit1.2 booleanCRT
32AC01 Status_ Mode Dry [DPT_1.002]1-DRY mode is active1 Bit1.2 booleanCRT
33AC01 Status_ Mode Text [DPT_16.001]Mode Text14 Bytes16.1 Character String (ISO 8859-1)CRT
34AC01 Status_ Fan Speed [DPT_5.001]33%, 66% and 100%1 Byte5.1 percentage (0..100%)CRT
34AC01 Status_ Fan Speed [DPT_5.010]Speed values: 1,2,31 Byte5.10 counter pulses (0..255)CRT
35AC01 Status_ Fan Speed Man/Auto [DPT_1.002]0-Manual;1-Auto1 Bit1.2 booleanCRT
36AC01 Status_ Fan Speed 1 [DPT_1.002]1-Fan in Speed 11 Bit1.2 booleanCRT
37AC01 Status_ Fan Speed 2 [DPT_1.002]1-Fan in Speed 21 Bit1.2 booleanCRT
38AC01 Status_ Fan Speed 3 [DPT_1.002]1-Fan in Speed 31 Bit1.2 booleanCRT
39AC01 Status_ Fan Speed Text [DPT_16.001]Fan Speed Text14 Bytes16.1 Character String (ISO 8859-1)CRT
40AC01 Status_ AC Setpoint Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
41AC01 Status_ AC Ambient Reference Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
42AC01 Status_ Error/Alarm [DPT_1.005]0-No alarm;1-Alarm1 Bit1.5 alarmCRT
43AC01 Status_ Error Code [2-byte signed value]Error Code2 Bytes8.1 pulses differenceCRT
44AC01 Status_ Error Text [DPT_16.001]Error Text14 Bytes16.1 Character String (ISO 8859-1)CRT
45AC01 Status_ Control Mode No Central [DPT_1.002]1-NO CENTRAL mode is active1 Bit1.2 booleanCRT
46AC01 Status_ Control Mode LIFO [DPT_1.002]1-LIFO mode is active1 Bit1.2 booleanCRT
47AC01 Status_ Control Mode Central [DPT_1.002]1-CENTRAL mode is active1 Bit1.2 booleanCRT
48AC01 Status_ Control Mode Lock [DPT_1.002]1-LOCK mode is active1 Bit1.2 booleanCRT
49AC02 Control_ On/Off [DPT_1.001]0-Off;1-On1 Bit1.1 switchCW
50AC02 Control_ Operating Mode [DPT_20.102]0-Aut;1-Com;2-Stan;3-Eco;4-Pro1 Byte20.102 HVAC modeCW
51AC02 Control_ Mode [DPT_20.105]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 Byte20.105 HVAC control modeCW
52AC02 Control_ Mode Cool/Heat [DPT_1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCW
53AC02 Control_ Mode Auto [DPT_1.002]1-Set AUTO mode1 Bit1.2 booleanCW
54AC02 Control_ Mode Heat [DPT_1.002]1-Set HEAT mode1 Bit1.2 booleanCW
55AC02 Control_ Mode Cool [DPT_1.002]1-Set COOL mode1 Bit1.2 booleanCW
56AC02 Control_ Mode Fan [DPT_1.002]1-Set FAN mode1 Bit1.2 booleanCW
57AC02 Control_ Mode Dry [DPT_1.002]1-Set DRY mode1 Bit1.2 booleanCW
58AC02 Control_ Mode +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
58AC02 Control_ Mode +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
59AC02 Control_ Fan Speed [DPT_5.001]Thresholds: 50% and 83%1 Byte5.1 percentage (0..100%)CW
59AC02 Control_ Fan Speed [DPT_5.010]Speed values: 1,2,31 Byte5.10 counter pulses (0..255)CW
60AC02 Control_ Fan Speed Man/Auto [DPT_1.002]0-Manual;1-Auto1 Bit1.2 booleanCW
61AC02 Control_ Fan Speed 1 [DPT_1.002]1-Set Fan Speed 11 Bit1.2 booleanCW
62AC02 Control_ Fan Speed 2 [DPT_1.002]1-Set Fan Speed 21 Bit1.2 booleanCW
63AC02 Control_ Fan Speed 3 [DPT_1.002]1-Set Fan Speed 31 Bit1.2 booleanCW
64AC02 Control_ Fan Speed +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
64AC02 Control_ Fan Speed +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
65AC02 Control_ Setpoint Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
66AC02 Control_ Setpoint Temperature +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
66AC02 Control_ Setpoint Temperature +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
67AC02 Control_ Ambient Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
68AC02 Control_ Control Mode No Central [DPT_1.002]1-Set NO CENTRAL mode1 Bit1.2 booleanCW
69AC02 Control_ Control Mode LIFO [DPT_1.002]1-Set LIFO mode1 Bit1.2 booleanCW
70AC02 Control_ Control Mode Central [DPT_1.002]1-Set CENTRAL mode1 Bit1.2 booleanCW
71AC02 Control_ Control Mode Lock [DPT_1.002]1-Set LOCK mode1 Bit1.2 booleanCW
72AC02 Status_ On/Off [DPT_1.001]0-Off;1-On1 Bit1.1 switchCRT
73AC02 Status_ Operating Mode [DPT_20.102]0-Aut;1-Com;2-Stan;3-Eco;4-Pro1 Byte20.102 HVAC modeCRT
74AC02 Status_ Mode [DPT_20.105]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 Byte20.105 HVAC control modeCRT
75AC02 Status_ Mode Cool/Heat [DPT_1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCRT
76AC02 Status_ Mode Auto [DPT_1.002]1-AUTO mode is active1 Bit1.2 booleanCRT
77AC02 Status_ Mode Heat [DPT_1.002]1-HEAT mode is active1 Bit1.2 booleanCRT
78AC02 Status_ Mode Cool [DPT_1.002]1-COOL mode is active1 Bit1.2 booleanCRT
79AC02 Status_ Mode Fan [DPT_1.002]1-FAN mode is active1 Bit1.2 booleanCRT
80AC02 Status_ Mode Dry [DPT_1.002]1-DRY mode is active1 Bit1.2 booleanCRT
81AC02 Status_ Mode Text [DPT_16.001]Mode Text14 Bytes16.1 Character String (ISO 8859-1)CRT
82AC02 Status_ Fan Speed [DPT_5.001]33%, 66% and 100%1 Byte5.1 percentage (0..100%)CRT
82AC02 Status_ Fan Speed [DPT_5.010]Speed values: 1,2,31 Byte5.10 counter pulses (0..255)CRT
83AC02 Status_ Fan Speed Man/Auto [DPT_1.002]0-Manual;1-Auto1 Bit1.2 booleanCRT
84AC02 Status_ Fan Speed 1 [DPT_1.002]1-Fan in Speed 11 Bit1.2 booleanCRT
85AC02 Status_ Fan Speed 2 [DPT_1.002]1-Fan in Speed 21 Bit1.2 booleanCRT
86AC02 Status_ Fan Speed 3 [DPT_1.002]1-Fan in Speed 31 Bit1.2 booleanCRT
87AC02 Status_ Fan Speed Text [DPT_16.001]Fan Speed Text14 Bytes16.1 Character String (ISO 8859-1)CRT
88AC02 Status_ AC Setpoint Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
89AC02 Status_ AC Ambient Reference Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
90AC02 Status_ Error/Alarm [DPT_1.005]0-No alarm;1-Alarm1 Bit1.5 alarmCRT
91AC02 Status_ Error Code [2-byte signed value]Error Code2 Bytes8.1 pulses differenceCRT
92AC02 Status_ Error Text [DPT_16.001]Error Text14 Bytes16.1 Character String (ISO 8859-1)CRT
93AC02 Status_ Control Mode No Central [DPT_1.002]1-NO CENTRAL mode is active1 Bit1.2 booleanCRT
94AC02 Status_ Control Mode LIFO [DPT_1.002]1-LIFO mode is active1 Bit1.2 booleanCRT
95AC02 Status_ Control Mode Central [DPT_1.002]1-CENTRAL mode is active1 Bit1.2 booleanCRT
96AC02 Status_ Control Mode Lock [DPT_1.002]1-LOCK mode is active1 Bit1.2 booleanCRT
97AC03 Control_ On/Off [DPT_1.001]0-Off;1-On1 Bit1.1 switchCW
98AC03 Control_ Operating Mode [DPT_20.102]0-Aut;1-Com;2-Stan;3-Eco;4-Pro1 Byte20.102 HVAC modeCW
99AC03 Control_ Mode [DPT_20.105]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 Byte20.105 HVAC control modeCW
100AC03 Control_ Mode Cool/Heat [DPT_1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCW
101AC03 Control_ Mode Auto [DPT_1.002]1-Set AUTO mode1 Bit1.2 booleanCW
102AC03 Control_ Mode Heat [DPT_1.002]1-Set HEAT mode1 Bit1.2 booleanCW
103AC03 Control_ Mode Cool [DPT_1.002]1-Set COOL mode1 Bit1.2 booleanCW
104AC03 Control_ Mode Fan [DPT_1.002]1-Set FAN mode1 Bit1.2 booleanCW
105AC03 Control_ Mode Dry [DPT_1.002]1-Set DRY mode1 Bit1.2 booleanCW
106AC03 Control_ Mode +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
106AC03 Control_ Mode +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
107AC03 Control_ Fan Speed [DPT_5.001]Thresholds: 50% and 83%1 Byte5.1 percentage (0..100%)CW
107AC03 Control_ Fan Speed [DPT_5.010]Speed values: 1,2,31 Byte5.10 counter pulses (0..255)CW
108AC03 Control_ Fan Speed Man/Auto [DPT_1.002]0-Manual;1-Auto1 Bit1.2 booleanCW
109AC03 Control_ Fan Speed 1 [DPT_1.002]1-Set Fan Speed 11 Bit1.2 booleanCW
110AC03 Control_ Fan Speed 2 [DPT_1.002]1-Set Fan Speed 21 Bit1.2 booleanCW
111AC03 Control_ Fan Speed 3 [DPT_1.002]1-Set Fan Speed 31 Bit1.2 booleanCW
112AC03 Control_ Fan Speed +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
112AC03 Control_ Fan Speed +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
113AC03 Control_ Setpoint Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
114AC03 Control_ Setpoint Temperature +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
114AC03 Control_ Setpoint Temperature +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
115AC03 Control_ Ambient Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
116AC03 Control_ Control Mode No Central [DPT_1.002]1-Set NO CENTRAL mode1 Bit1.2 booleanCW
117AC03 Control_ Control Mode LIFO [DPT_1.002]1-Set LIFO mode1 Bit1.2 booleanCW
118AC03 Control_ Control Mode Central [DPT_1.002]1-Set CENTRAL mode1 Bit1.2 booleanCW
119AC03 Control_ Control Mode Lock [DPT_1.002]1-Set LOCK mode1 Bit1.2 booleanCW
120AC03 Status_ On/Off [DPT_1.001]0-Off;1-On1 Bit1.1 switchCRT
121AC03 Status_ Operating Mode [DPT_20.102]0-Aut;1-Com;2-Stan;3-Eco;4-Pro1 Byte20.102 HVAC modeCRT
122AC03 Status_ Mode [DPT_20.105]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 Byte20.105 HVAC control modeCRT
123AC03 Status_ Mode Cool/Heat [DPT_1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCRT
124AC03 Status_ Mode Auto [DPT_1.002]1-AUTO mode is active1 Bit1.2 booleanCRT
125AC03 Status_ Mode Heat [DPT_1.002]1-HEAT mode is active1 Bit1.2 booleanCRT
126AC03 Status_ Mode Cool [DPT_1.002]1-COOL mode is active1 Bit1.2 booleanCRT
127AC03 Status_ Mode Fan [DPT_1.002]1-FAN mode is active1 Bit1.2 booleanCRT
128AC03 Status_ Mode Dry [DPT_1.002]1-DRY mode is active1 Bit1.2 booleanCRT
129AC03 Status_ Mode Text [DPT_16.001]Mode Text14 Bytes16.1 Character String (ISO 8859-1)CRT
130AC03 Status_ Fan Speed [DPT_5.001]33%, 66% and 100%1 Byte5.1 percentage (0..100%)CRT
130AC03 Status_ Fan Speed [DPT_5.010]Speed values: 1,2,31 Byte5.10 counter pulses (0..255)CRT
131AC03 Status_ Fan Speed Man/Auto [DPT_1.002]0-Manual;1-Auto1 Bit1.2 booleanCRT
132AC03 Status_ Fan Speed 1 [DPT_1.002]1-Fan in Speed 11 Bit1.2 booleanCRT
133AC03 Status_ Fan Speed 2 [DPT_1.002]1-Fan in Speed 21 Bit1.2 booleanCRT
134AC03 Status_ Fan Speed 3 [DPT_1.002]1-Fan in Speed 31 Bit1.2 booleanCRT
135AC03 Status_ Fan Speed Text [DPT_16.001]Fan Speed Text14 Bytes16.1 Character String (ISO 8859-1)CRT
136AC03 Status_ AC Setpoint Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
137AC03 Status_ AC Ambient Reference Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
138AC03 Status_ Error/Alarm [DPT_1.005]0-No alarm;1-Alarm1 Bit1.5 alarmCRT
139AC03 Status_ Error Code [2-byte signed value]Error Code2 Bytes8.1 pulses differenceCRT
140AC03 Status_ Error Text [DPT_16.001]Error Text14 Bytes16.1 Character String (ISO 8859-1)CRT
141AC03 Status_ Control Mode No Central [DPT_1.002]1-NO CENTRAL mode is active1 Bit1.2 booleanCRT
142AC03 Status_ Control Mode LIFO [DPT_1.002]1-LIFO mode is active1 Bit1.2 booleanCRT
143AC03 Status_ Control Mode Central [DPT_1.002]1-CENTRAL mode is active1 Bit1.2 booleanCRT
144AC03 Status_ Control Mode Lock [DPT_1.002]1-LOCK mode is active1 Bit1.2 booleanCRT
145AC04 Control_ On/Off [DPT_1.001]0-Off;1-On1 Bit1.1 switchCW
146AC04 Control_ Operating Mode [DPT_20.102]0-Aut;1-Com;2-Stan;3-Eco;4-Pro1 Byte20.102 HVAC modeCW
147AC04 Control_ Mode [DPT_20.105]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 Byte20.105 HVAC control modeCW
148AC04 Control_ Mode Cool/Heat [DPT_1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCW
149AC04 Control_ Mode Auto [DPT_1.002]1-Set AUTO mode1 Bit1.2 booleanCW
150AC04 Control_ Mode Heat [DPT_1.002]1-Set HEAT mode1 Bit1.2 booleanCW
151AC04 Control_ Mode Cool [DPT_1.002]1-Set COOL mode1 Bit1.2 booleanCW
152AC04 Control_ Mode Fan [DPT_1.002]1-Set FAN mode1 Bit1.2 booleanCW
153AC04 Control_ Mode Dry [DPT_1.002]1-Set DRY mode1 Bit1.2 booleanCW
154AC04 Control_ Mode +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
154AC04 Control_ Mode +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
155AC04 Control_ Fan Speed [DPT_5.001]Thresholds: 50% and 83%1 Byte5.1 percentage (0..100%)CW
155AC04 Control_ Fan Speed [DPT_5.010]Speed values: 1,2,31 Byte5.10 counter pulses (0..255)CW
156AC04 Control_ Fan Speed Man/Auto [DPT_1.002]0-Manual;1-Auto1 Bit1.2 booleanCW
157AC04 Control_ Fan Speed 1 [DPT_1.002]1-Set Fan Speed 11 Bit1.2 booleanCW
158AC04 Control_ Fan Speed 2 [DPT_1.002]1-Set Fan Speed 21 Bit1.2 booleanCW
159AC04 Control_ Fan Speed 3 [DPT_1.002]1-Set Fan Speed 31 Bit1.2 booleanCW
160AC04 Control_ Fan Speed +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
160AC04 Control_ Fan Speed +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
161AC04 Control_ Setpoint Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
162AC04 Control_ Setpoint Temperature +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
162AC04 Control_ Setpoint Temperature +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
163AC04 Control_ Ambient Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
164AC04 Control_ Control Mode No Central [DPT_1.002]1-Set NO CENTRAL mode1 Bit1.2 booleanCW
165AC04 Control_ Control Mode LIFO [DPT_1.002]1-Set LIFO mode1 Bit1.2 booleanCW
166AC04 Control_ Control Mode Central [DPT_1.002]1-Set CENTRAL mode1 Bit1.2 booleanCW
167AC04 Control_ Control Mode Lock [DPT_1.002]1-Set LOCK mode1 Bit1.2 booleanCW
168AC04 Status_ On/Off [DPT_1.001]0-Off;1-On1 Bit1.1 switchCRT
169AC04 Status_ Operating Mode [DPT_20.102]0-Aut;1-Com;2-Stan;3-Eco;4-Pro1 Byte20.102 HVAC modeCRT
170AC04 Status_ Mode [DPT_20.105]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 Byte20.105 HVAC control modeCRT
171AC04 Status_ Mode Cool/Heat [DPT_1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCRT
172AC04 Status_ Mode Auto [DPT_1.002]1-AUTO mode is active1 Bit1.2 booleanCRT
173AC04 Status_ Mode Heat [DPT_1.002]1-HEAT mode is active1 Bit1.2 booleanCRT
174AC04 Status_ Mode Cool [DPT_1.002]1-COOL mode is active1 Bit1.2 booleanCRT
175AC04 Status_ Mode Fan [DPT_1.002]1-FAN mode is active1 Bit1.2 booleanCRT
176AC04 Status_ Mode Dry [DPT_1.002]1-DRY mode is active1 Bit1.2 booleanCRT
177AC04 Status_ Mode Text [DPT_16.001]Mode Text14 Bytes16.1 Character String (ISO 8859-1)CRT
178AC04 Status_ Fan Speed [DPT_5.001]33%, 66% and 100%1 Byte5.1 percentage (0..100%)CRT
178AC04 Status_ Fan Speed [DPT_5.010]Speed values: 1,2,31 Byte5.10 counter pulses (0..255)CRT
179AC04 Status_ Fan Speed Man/Auto [DPT_1.002]0-Manual;1-Auto1 Bit1.2 booleanCRT
180AC04 Status_ Fan Speed 1 [DPT_1.002]1-Fan in Speed 11 Bit1.2 booleanCRT
181AC04 Status_ Fan Speed 2 [DPT_1.002]1-Fan in Speed 21 Bit1.2 booleanCRT
182AC04 Status_ Fan Speed 3 [DPT_1.002]1-Fan in Speed 31 Bit1.2 booleanCRT
183AC04 Status_ Fan Speed Text [DPT_16.001]Fan Speed Text14 Bytes16.1 Character String (ISO 8859-1)CRT
184AC04 Status_ AC Setpoint Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
185AC04 Status_ AC Ambient Reference Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
186AC04 Status_ Error/Alarm [DPT_1.005]0-No alarm;1-Alarm1 Bit1.5 alarmCRT
187AC04 Status_ Error Code [2-byte signed value]Error Code2 Bytes8.1 pulses differenceCRT
188AC04 Status_ Error Text [DPT_16.001]Error Text14 Bytes16.1 Character String (ISO 8859-1)CRT
189AC04 Status_ Control Mode No Central [DPT_1.002]1-NO CENTRAL mode is active1 Bit1.2 booleanCRT
190AC04 Status_ Control Mode LIFO [DPT_1.002]1-LIFO mode is active1 Bit1.2 booleanCRT
191AC04 Status_ Control Mode Central [DPT_1.002]1-CENTRAL mode is active1 Bit1.2 booleanCRT
192AC04 Status_ Control Mode Lock [DPT_1.002]1-LOCK mode is active1 Bit1.2 booleanCRT
193AC05 Control_ On/Off [DPT_1.001]0-Off;1-On1 Bit1.1 switchCW
194AC05 Control_ Operating Mode [DPT_20.102]0-Aut;1-Com;2-Stan;3-Eco;4-Pro1 Byte20.102 HVAC modeCW
195AC05 Control_ Mode [DPT_20.105]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 Byte20.105 HVAC control modeCW
196AC05 Control_ Mode Cool/Heat [DPT_1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCW
197AC05 Control_ Mode Auto [DPT_1.002]1-Set AUTO mode1 Bit1.2 booleanCW
198AC05 Control_ Mode Heat [DPT_1.002]1-Set HEAT mode1 Bit1.2 booleanCW
199AC05 Control_ Mode Cool [DPT_1.002]1-Set COOL mode1 Bit1.2 booleanCW
200AC05 Control_ Mode Fan [DPT_1.002]1-Set FAN mode1 Bit1.2 booleanCW
201AC05 Control_ Mode Dry [DPT_1.002]1-Set DRY mode1 Bit1.2 booleanCW
202AC05 Control_ Mode +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
202AC05 Control_ Mode +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
203AC05 Control_ Fan Speed [DPT_5.001]Thresholds: 50% and 83%1 Byte5.1 percentage (0..100%)CW
203AC05 Control_ Fan Speed [DPT_5.010]Speed values: 1,2,31 Byte5.10 counter pulses (0..255)CW
204AC05 Control_ Fan Speed Man/Auto [DPT_1.002]0-Manual;1-Auto1 Bit1.2 booleanCW
205AC05 Control_ Fan Speed 1 [DPT_1.002]1-Set Fan Speed 11 Bit1.2 booleanCW
206AC05 Control_ Fan Speed 2 [DPT_1.002]1-Set Fan Speed 21 Bit1.2 booleanCW
207AC05 Control_ Fan Speed 3 [DPT_1.002]1-Set Fan Speed 31 Bit1.2 booleanCW
208AC05 Control_ Fan Speed +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
208AC05 Control_ Fan Speed +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
209AC05 Control_ Setpoint Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
210AC05 Control_ Setpoint Temperature +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
210AC05 Control_ Setpoint Temperature +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
211AC05 Control_ Ambient Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
212AC05 Control_ Control Mode No Central [DPT_1.002]1-Set NO CENTRAL mode1 Bit1.2 booleanCW
213AC05 Control_ Control Mode LIFO [DPT_1.002]1-Set LIFO mode1 Bit1.2 booleanCW
214AC05 Control_ Control Mode Central [DPT_1.002]1-Set CENTRAL mode1 Bit1.2 booleanCW
215AC05 Control_ Control Mode Lock [DPT_1.002]1-Set LOCK mode1 Bit1.2 booleanCW
216AC05 Status_ On/Off [DPT_1.001]0-Off;1-On1 Bit1.1 switchCRT
217AC05 Status_ Operating Mode [DPT_20.102]0-Aut;1-Com;2-Stan;3-Eco;4-Pro1 Byte20.102 HVAC modeCRT
218AC05 Status_ Mode [DPT_20.105]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 Byte20.105 HVAC control modeCRT
219AC05 Status_ Mode Cool/Heat [DPT_1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCRT
220AC05 Status_ Mode Auto [DPT_1.002]1-AUTO mode is active1 Bit1.2 booleanCRT
221AC05 Status_ Mode Heat [DPT_1.002]1-HEAT mode is active1 Bit1.2 booleanCRT
222AC05 Status_ Mode Cool [DPT_1.002]1-COOL mode is active1 Bit1.2 booleanCRT
223AC05 Status_ Mode Fan [DPT_1.002]1-FAN mode is active1 Bit1.2 booleanCRT
224AC05 Status_ Mode Dry [DPT_1.002]1-DRY mode is active1 Bit1.2 booleanCRT
225AC05 Status_ Mode Text [DPT_16.001]Mode Text14 Bytes16.1 Character String (ISO 8859-1)CRT
226AC05 Status_ Fan Speed [DPT_5.001]33%, 66% and 100%1 Byte5.1 percentage (0..100%)CRT
226AC05 Status_ Fan Speed [DPT_5.010]Speed values: 1,2,31 Byte5.10 counter pulses (0..255)CRT
227AC05 Status_ Fan Speed Man/Auto [DPT_1.002]0-Manual;1-Auto1 Bit1.2 booleanCRT
228AC05 Status_ Fan Speed 1 [DPT_1.002]1-Fan in Speed 11 Bit1.2 booleanCRT
229AC05 Status_ Fan Speed 2 [DPT_1.002]1-Fan in Speed 21 Bit1.2 booleanCRT
230AC05 Status_ Fan Speed 3 [DPT_1.002]1-Fan in Speed 31 Bit1.2 booleanCRT
231AC05 Status_ Fan Speed Text [DPT_16.001]Fan Speed Text14 Bytes16.1 Character String (ISO 8859-1)CRT
232AC05 Status_ AC Setpoint Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
233AC05 Status_ AC Ambient Reference Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
234AC05 Status_ Error/Alarm [DPT_1.005]0-No alarm;1-Alarm1 Bit1.5 alarmCRT
235AC05 Status_ Error Code [2-byte signed value]Error Code2 Bytes8.1 pulses differenceCRT
236AC05 Status_ Error Text [DPT_16.001]Error Text14 Bytes16.1 Character String (ISO 8859-1)CRT
237AC05 Status_ Control Mode No Central [DPT_1.002]1-NO CENTRAL mode is active1 Bit1.2 booleanCRT
238AC05 Status_ Control Mode LIFO [DPT_1.002]1-LIFO mode is active1 Bit1.2 booleanCRT
239AC05 Status_ Control Mode Central [DPT_1.002]1-CENTRAL mode is active1 Bit1.2 booleanCRT
240AC05 Status_ Control Mode Lock [DPT_1.002]1-LOCK mode is active1 Bit1.2 booleanCRT
241AC06 Control_ On/Off [DPT_1.001]0-Off;1-On1 Bit1.1 switchCW
242AC06 Control_ Operating Mode [DPT_20.102]0-Aut;1-Com;2-Stan;3-Eco;4-Pro1 Byte20.102 HVAC modeCW
243AC06 Control_ Mode [DPT_20.105]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 Byte20.105 HVAC control modeCW
244AC06 Control_ Mode Cool/Heat [DPT_1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCW
245AC06 Control_ Mode Auto [DPT_1.002]1-Set AUTO mode1 Bit1.2 booleanCW
246AC06 Control_ Mode Heat [DPT_1.002]1-Set HEAT mode1 Bit1.2 booleanCW
247AC06 Control_ Mode Cool [DPT_1.002]1-Set COOL mode1 Bit1.2 booleanCW
248AC06 Control_ Mode Fan [DPT_1.002]1-Set FAN mode1 Bit1.2 booleanCW
249AC06 Control_ Mode Dry [DPT_1.002]1-Set DRY mode1 Bit1.2 booleanCW
250AC06 Control_ Mode +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
250AC06 Control_ Mode +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
251AC06 Control_ Fan Speed [DPT_5.001]Thresholds: 50% and 83%1 Byte5.1 percentage (0..100%)CW
251AC06 Control_ Fan Speed [DPT_5.010]Speed values: 1,2,31 Byte5.10 counter pulses (0..255)CW
252AC06 Control_ Fan Speed Man/Auto [DPT_1.002]0-Manual;1-Auto1 Bit1.2 booleanCW
253AC06 Control_ Fan Speed 1 [DPT_1.002]1-Set Fan Speed 11 Bit1.2 booleanCW
254AC06 Control_ Fan Speed 2 [DPT_1.002]1-Set Fan Speed 21 Bit1.2 booleanCW
255AC06 Control_ Fan Speed 3 [DPT_1.002]1-Set Fan Speed 31 Bit1.2 booleanCW
256AC06 Control_ Fan Speed +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
256AC06 Control_ Fan Speed +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
257AC06 Control_ Setpoint Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
258AC06 Control_ Setpoint Temperature +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
258AC06 Control_ Setpoint Temperature +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
259AC06 Control_ Ambient Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
260AC06 Control_ Control Mode No Central [DPT_1.002]1-Set NO CENTRAL mode1 Bit1.2 booleanCW
261AC06 Control_ Control Mode LIFO [DPT_1.002]1-Set LIFO mode1 Bit1.2 booleanCW
262AC06 Control_ Control Mode Central [DPT_1.002]1-Set CENTRAL mode1 Bit1.2 booleanCW
263AC06 Control_ Control Mode Lock [DPT_1.002]1-Set LOCK mode1 Bit1.2 booleanCW
264AC06 Status_ On/Off [DPT_1.001]0-Off;1-On1 Bit1.1 switchCRT
265AC06 Status_ Operating Mode [DPT_20.102]0-Aut;1-Com;2-Stan;3-Eco;4-Pro1 Byte20.102 HVAC modeCRT
266AC06 Status_ Mode [DPT_20.105]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 Byte20.105 HVAC control modeCRT
267AC06 Status_ Mode Cool/Heat [DPT_1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCRT
268AC06 Status_ Mode Auto [DPT_1.002]1-AUTO mode is active1 Bit1.2 booleanCRT
269AC06 Status_ Mode Heat [DPT_1.002]1-HEAT mode is active1 Bit1.2 booleanCRT
270AC06 Status_ Mode Cool [DPT_1.002]1-COOL mode is active1 Bit1.2 booleanCRT
271AC06 Status_ Mode Fan [DPT_1.002]1-FAN mode is active1 Bit1.2 booleanCRT
272AC06 Status_ Mode Dry [DPT_1.002]1-DRY mode is active1 Bit1.2 booleanCRT
273AC06 Status_ Mode Text [DPT_16.001]Mode Text14 Bytes16.1 Character String (ISO 8859-1)CRT
274AC06 Status_ Fan Speed [DPT_5.001]33%, 66% and 100%1 Byte5.1 percentage (0..100%)CRT
274AC06 Status_ Fan Speed [DPT_5.010]Speed values: 1,2,31 Byte5.10 counter pulses (0..255)CRT
275AC06 Status_ Fan Speed Man/Auto [DPT_1.002]0-Manual;1-Auto1 Bit1.2 booleanCRT
276AC06 Status_ Fan Speed 1 [DPT_1.002]1-Fan in Speed 11 Bit1.2 booleanCRT
277AC06 Status_ Fan Speed 2 [DPT_1.002]1-Fan in Speed 21 Bit1.2 booleanCRT
278AC06 Status_ Fan Speed 3 [DPT_1.002]1-Fan in Speed 31 Bit1.2 booleanCRT
279AC06 Status_ Fan Speed Text [DPT_16.001]Fan Speed Text14 Bytes16.1 Character String (ISO 8859-1)CRT
280AC06 Status_ AC Setpoint Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
281AC06 Status_ AC Ambient Reference Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
282AC06 Status_ Error/Alarm [DPT_1.005]0-No alarm;1-Alarm1 Bit1.5 alarmCRT
283AC06 Status_ Error Code [2-byte signed value]Error Code2 Bytes8.1 pulses differenceCRT
284AC06 Status_ Error Text [DPT_16.001]Error Text14 Bytes16.1 Character String (ISO 8859-1)CRT
285AC06 Status_ Control Mode No Central [DPT_1.002]1-NO CENTRAL mode is active1 Bit1.2 booleanCRT
286AC06 Status_ Control Mode LIFO [DPT_1.002]1-LIFO mode is active1 Bit1.2 booleanCRT
287AC06 Status_ Control Mode Central [DPT_1.002]1-CENTRAL mode is active1 Bit1.2 booleanCRT
288AC06 Status_ Control Mode Lock [DPT_1.002]1-LOCK mode is active1 Bit1.2 booleanCRT
289AC07 Control_ On/Off [DPT_1.001]0-Off;1-On1 Bit1.1 switchCW
290AC07 Control_ Operating Mode [DPT_20.102]0-Aut;1-Com;2-Stan;3-Eco;4-Pro1 Byte20.102 HVAC modeCW
291AC07 Control_ Mode [DPT_20.105]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 Byte20.105 HVAC control modeCW
292AC07 Control_ Mode Cool/Heat [DPT_1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCW
293AC07 Control_ Mode Auto [DPT_1.002]1-Set AUTO mode1 Bit1.2 booleanCW
294AC07 Control_ Mode Heat [DPT_1.002]1-Set HEAT mode1 Bit1.2 booleanCW
295AC07 Control_ Mode Cool [DPT_1.002]1-Set COOL mode1 Bit1.2 booleanCW
296AC07 Control_ Mode Fan [DPT_1.002]1-Set FAN mode1 Bit1.2 booleanCW
297AC07 Control_ Mode Dry [DPT_1.002]1-Set DRY mode1 Bit1.2 booleanCW
298AC07 Control_ Mode +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
298AC07 Control_ Mode +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
299AC07 Control_ Fan Speed [DPT_5.001]Thresholds: 50% and 83%1 Byte5.1 percentage (0..100%)CW
299AC07 Control_ Fan Speed [DPT_5.010]Speed values: 1,2,31 Byte5.10 counter pulses (0..255)CW
300AC07 Control_ Fan Speed Man/Auto [DPT_1.002]0-Manual;1-Auto1 Bit1.2 booleanCW
301AC07 Control_ Fan Speed 1 [DPT_1.002]1-Set Fan Speed 11 Bit1.2 booleanCW
302AC07 Control_ Fan Speed 2 [DPT_1.002]1-Set Fan Speed 21 Bit1.2 booleanCW
303AC07 Control_ Fan Speed 3 [DPT_1.002]1-Set Fan Speed 31 Bit1.2 booleanCW
304AC07 Control_ Fan Speed +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
304AC07 Control_ Fan Speed +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
305AC07 Control_ Setpoint Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
306AC07 Control_ Setpoint Temperature +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
306AC07 Control_ Setpoint Temperature +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
307AC07 Control_ Ambient Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
308AC07 Control_ Control Mode No Central [DPT_1.002]1-Set NO CENTRAL mode1 Bit1.2 booleanCW
309AC07 Control_ Control Mode LIFO [DPT_1.002]1-Set LIFO mode1 Bit1.2 booleanCW
310AC07 Control_ Control Mode Central [DPT_1.002]1-Set CENTRAL mode1 Bit1.2 booleanCW
311AC07 Control_ Control Mode Lock [DPT_1.002]1-Set LOCK mode1 Bit1.2 booleanCW
312AC07 Status_ On/Off [DPT_1.001]0-Off;1-On1 Bit1.1 switchCRT
313AC07 Status_ Operating Mode [DPT_20.102]0-Aut;1-Com;2-Stan;3-Eco;4-Pro1 Byte20.102 HVAC modeCRT
314AC07 Status_ Mode [DPT_20.105]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 Byte20.105 HVAC control modeCRT
315AC07 Status_ Mode Cool/Heat [DPT_1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCRT
316AC07 Status_ Mode Auto [DPT_1.002]1-AUTO mode is active1 Bit1.2 booleanCRT
317AC07 Status_ Mode Heat [DPT_1.002]1-HEAT mode is active1 Bit1.2 booleanCRT
318AC07 Status_ Mode Cool [DPT_1.002]1-COOL mode is active1 Bit1.2 booleanCRT
319AC07 Status_ Mode Fan [DPT_1.002]1-FAN mode is active1 Bit1.2 booleanCRT
320AC07 Status_ Mode Dry [DPT_1.002]1-DRY mode is active1 Bit1.2 booleanCRT
321AC07 Status_ Mode Text [DPT_16.001]Mode Text14 Bytes16.1 Character String (ISO 8859-1)CRT
322AC07 Status_ Fan Speed [DPT_5.001]33%, 66% and 100%1 Byte5.1 percentage (0..100%)CRT
322AC07 Status_ Fan Speed [DPT_5.010]Speed values: 1,2,31 Byte5.10 counter pulses (0..255)CRT
323AC07 Status_ Fan Speed Man/Auto [DPT_1.002]0-Manual;1-Auto1 Bit1.2 booleanCRT
324AC07 Status_ Fan Speed 1 [DPT_1.002]1-Fan in Speed 11 Bit1.2 booleanCRT
325AC07 Status_ Fan Speed 2 [DPT_1.002]1-Fan in Speed 21 Bit1.2 booleanCRT
326AC07 Status_ Fan Speed 3 [DPT_1.002]1-Fan in Speed 31 Bit1.2 booleanCRT
327AC07 Status_ Fan Speed Text [DPT_16.001]Fan Speed Text14 Bytes16.1 Character String (ISO 8859-1)CRT
328AC07 Status_ AC Setpoint Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
329AC07 Status_ AC Ambient Reference Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
330AC07 Status_ Error/Alarm [DPT_1.005]0-No alarm;1-Alarm1 Bit1.5 alarmCRT
331AC07 Status_ Error Code [2-byte signed value]Error Code2 Bytes8.1 pulses differenceCRT
332AC07 Status_ Error Text [DPT_16.001]Error Text14 Bytes16.1 Character String (ISO 8859-1)CRT
333AC07 Status_ Control Mode No Central [DPT_1.002]1-NO CENTRAL mode is active1 Bit1.2 booleanCRT
334AC07 Status_ Control Mode LIFO [DPT_1.002]1-LIFO mode is active1 Bit1.2 booleanCRT
335AC07 Status_ Control Mode Central [DPT_1.002]1-CENTRAL mode is active1 Bit1.2 booleanCRT
336AC07 Status_ Control Mode Lock [DPT_1.002]1-LOCK mode is active1 Bit1.2 booleanCRT
337AC08 Control_ On/Off [DPT_1.001]0-Off;1-On1 Bit1.1 switchCW
338AC08 Control_ Operating Mode [DPT_20.102]0-Aut;1-Com;2-Stan;3-Eco;4-Pro1 Byte20.102 HVAC modeCW
339AC08 Control_ Mode [DPT_20.105]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 Byte20.105 HVAC control modeCW
340AC08 Control_ Mode Cool/Heat [DPT_1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCW
341AC08 Control_ Mode Auto [DPT_1.002]1-Set AUTO mode1 Bit1.2 booleanCW
342AC08 Control_ Mode Heat [DPT_1.002]1-Set HEAT mode1 Bit1.2 booleanCW
343AC08 Control_ Mode Cool [DPT_1.002]1-Set COOL mode1 Bit1.2 booleanCW
344AC08 Control_ Mode Fan [DPT_1.002]1-Set FAN mode1 Bit1.2 booleanCW
345AC08 Control_ Mode Dry [DPT_1.002]1-Set DRY mode1 Bit1.2 booleanCW
346AC08 Control_ Mode +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
346AC08 Control_ Mode +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
347AC08 Control_ Fan Speed [DPT_5.001]Thresholds: 50% and 83%1 Byte5.1 percentage (0..100%)CW
347AC08 Control_ Fan Speed [DPT_5.010]Speed values: 1,2,31 Byte5.10 counter pulses (0..255)CW
348AC08 Control_ Fan Speed Man/Auto [DPT_1.002]0-Manual;1-Auto1 Bit1.2 booleanCW
349AC08 Control_ Fan Speed 1 [DPT_1.002]1-Set Fan Speed 11 Bit1.2 booleanCW
350AC08 Control_ Fan Speed 2 [DPT_1.002]1-Set Fan Speed 21 Bit1.2 booleanCW
351AC08 Control_ Fan Speed 3 [DPT_1.002]1-Set Fan Speed 31 Bit1.2 booleanCW
352AC08 Control_ Fan Speed +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
352AC08 Control_ Fan Speed +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
353AC08 Control_ Setpoint Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
354AC08 Control_ Setpoint Temperature +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
354AC08 Control_ Setpoint Temperature +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
355AC08 Control_ Ambient Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
356AC08 Control_ Control Mode No Central [DPT_1.002]1-Set NO CENTRAL mode1 Bit1.2 booleanCW
357AC08 Control_ Control Mode LIFO [DPT_1.002]1-Set LIFO mode1 Bit1.2 booleanCW
358AC08 Control_ Control Mode Central [DPT_1.002]1-Set CENTRAL mode1 Bit1.2 booleanCW
359AC08 Control_ Control Mode Lock [DPT_1.002]1-Set LOCK mode1 Bit1.2 booleanCW
360AC08 Status_ On/Off [DPT_1.001]0-Off;1-On1 Bit1.1 switchCRT
361AC08 Status_ Operating Mode [DPT_20.102]0-Aut;1-Com;2-Stan;3-Eco;4-Pro1 Byte20.102 HVAC modeCRT
362AC08 Status_ Mode [DPT_20.105]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 Byte20.105 HVAC control modeCRT
363AC08 Status_ Mode Cool/Heat [DPT_1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCRT
364AC08 Status_ Mode Auto [DPT_1.002]1-AUTO mode is active1 Bit1.2 booleanCRT
365AC08 Status_ Mode Heat [DPT_1.002]1-HEAT mode is active1 Bit1.2 booleanCRT
366AC08 Status_ Mode Cool [DPT_1.002]1-COOL mode is active1 Bit1.2 booleanCRT
367AC08 Status_ Mode Fan [DPT_1.002]1-FAN mode is active1 Bit1.2 booleanCRT
368AC08 Status_ Mode Dry [DPT_1.002]1-DRY mode is active1 Bit1.2 booleanCRT
369AC08 Status_ Mode Text [DPT_16.001]Mode Text14 Bytes16.1 Character String (ISO 8859-1)CRT
370AC08 Status_ Fan Speed [DPT_5.001]33%, 66% and 100%1 Byte5.1 percentage (0..100%)CRT
370AC08 Status_ Fan Speed [DPT_5.010]Speed values: 1,2,31 Byte5.10 counter pulses (0..255)CRT
371AC08 Status_ Fan Speed Man/Auto [DPT_1.002]0-Manual;1-Auto1 Bit1.2 booleanCRT
372AC08 Status_ Fan Speed 1 [DPT_1.002]1-Fan in Speed 11 Bit1.2 booleanCRT
373AC08 Status_ Fan Speed 2 [DPT_1.002]1-Fan in Speed 21 Bit1.2 booleanCRT
374AC08 Status_ Fan Speed 3 [DPT_1.002]1-Fan in Speed 31 Bit1.2 booleanCRT
375AC08 Status_ Fan Speed Text [DPT_16.001]Fan Speed Text14 Bytes16.1 Character String (ISO 8859-1)CRT
376AC08 Status_ AC Setpoint Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
377AC08 Status_ AC Ambient Reference Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
378AC08 Status_ Error/Alarm [DPT_1.005]0-No alarm;1-Alarm1 Bit1.5 alarmCRT
379AC08 Status_ Error Code [2-byte signed value]Error Code2 Bytes8.1 pulses differenceCRT
380AC08 Status_ Error Text [DPT_16.001]Error Text14 Bytes16.1 Character String (ISO 8859-1)CRT
381AC08 Status_ Control Mode No Central [DPT_1.002]1-NO CENTRAL mode is active1 Bit1.2 booleanCRT
382AC08 Status_ Control Mode LIFO [DPT_1.002]1-LIFO mode is active1 Bit1.2 booleanCRT
383AC08 Status_ Control Mode Central [DPT_1.002]1-CENTRAL mode is active1 Bit1.2 booleanCRT
384AC08 Status_ Control Mode Lock [DPT_1.002]1-LOCK mode is active1 Bit1.2 booleanCRT
385AC09 Control_ On/Off [DPT_1.001]0-Off;1-On1 Bit1.1 switchCW
386AC09 Control_ Operating Mode [DPT_20.102]0-Aut;1-Com;2-Stan;3-Eco;4-Pro1 Byte20.102 HVAC modeCW
387AC09 Control_ Mode [DPT_20.105]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 Byte20.105 HVAC control modeCW
388AC09 Control_ Mode Cool/Heat [DPT_1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCW
389AC09 Control_ Mode Auto [DPT_1.002]1-Set AUTO mode1 Bit1.2 booleanCW
390AC09 Control_ Mode Heat [DPT_1.002]1-Set HEAT mode1 Bit1.2 booleanCW
391AC09 Control_ Mode Cool [DPT_1.002]1-Set COOL mode1 Bit1.2 booleanCW
392AC09 Control_ Mode Fan [DPT_1.002]1-Set FAN mode1 Bit1.2 booleanCW
393AC09 Control_ Mode Dry [DPT_1.002]1-Set DRY mode1 Bit1.2 booleanCW
394AC09 Control_ Mode +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
394AC09 Control_ Mode +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
395AC09 Control_ Fan Speed [DPT_5.001]Thresholds: 50% and 83%1 Byte5.1 percentage (0..100%)CW
395AC09 Control_ Fan Speed [DPT_5.010]Speed values: 1,2,31 Byte5.10 counter pulses (0..255)CW
396AC09 Control_ Fan Speed Man/Auto [DPT_1.002]0-Manual;1-Auto1 Bit1.2 booleanCW
397AC09 Control_ Fan Speed 1 [DPT_1.002]1-Set Fan Speed 11 Bit1.2 booleanCW
398AC09 Control_ Fan Speed 2 [DPT_1.002]1-Set Fan Speed 21 Bit1.2 booleanCW
399AC09 Control_ Fan Speed 3 [DPT_1.002]1-Set Fan Speed 31 Bit1.2 booleanCW
400AC09 Control_ Fan Speed +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
400AC09 Control_ Fan Speed +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
401AC09 Control_ Setpoint Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
402AC09 Control_ Setpoint Temperature +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
402AC09 Control_ Setpoint Temperature +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
403AC09 Control_ Ambient Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
404AC09 Control_ Control Mode No Central [DPT_1.002]1-Set NO CENTRAL mode1 Bit1.2 booleanCW
405AC09 Control_ Control Mode LIFO [DPT_1.002]1-Set LIFO mode1 Bit1.2 booleanCW
406AC09 Control_ Control Mode Central [DPT_1.002]1-Set CENTRAL mode1 Bit1.2 booleanCW
407AC09 Control_ Control Mode Lock [DPT_1.002]1-Set LOCK mode1 Bit1.2 booleanCW
408AC09 Status_ On/Off [DPT_1.001]0-Off;1-On1 Bit1.1 switchCRT
409AC09 Status_ Operating Mode [DPT_20.102]0-Aut;1-Com;2-Stan;3-Eco;4-Pro1 Byte20.102 HVAC modeCRT
410AC09 Status_ Mode [DPT_20.105]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 Byte20.105 HVAC control modeCRT
411AC09 Status_ Mode Cool/Heat [DPT_1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCRT
412AC09 Status_ Mode Auto [DPT_1.002]1-AUTO mode is active1 Bit1.2 booleanCRT
413AC09 Status_ Mode Heat [DPT_1.002]1-HEAT mode is active1 Bit1.2 booleanCRT
414AC09 Status_ Mode Cool [DPT_1.002]1-COOL mode is active1 Bit1.2 booleanCRT
415AC09 Status_ Mode Fan [DPT_1.002]1-FAN mode is active1 Bit1.2 booleanCRT
416AC09 Status_ Mode Dry [DPT_1.002]1-DRY mode is active1 Bit1.2 booleanCRT
417AC09 Status_ Mode Text [DPT_16.001]Mode Text14 Bytes16.1 Character String (ISO 8859-1)CRT
418AC09 Status_ Fan Speed [DPT_5.001]33%, 66% and 100%1 Byte5.1 percentage (0..100%)CRT
418AC09 Status_ Fan Speed [DPT_5.010]Speed values: 1,2,31 Byte5.10 counter pulses (0..255)CRT
419AC09 Status_ Fan Speed Man/Auto [DPT_1.002]0-Manual;1-Auto1 Bit1.2 booleanCRT
420AC09 Status_ Fan Speed 1 [DPT_1.002]1-Fan in Speed 11 Bit1.2 booleanCRT
421AC09 Status_ Fan Speed 2 [DPT_1.002]1-Fan in Speed 21 Bit1.2 booleanCRT
422AC09 Status_ Fan Speed 3 [DPT_1.002]1-Fan in Speed 31 Bit1.2 booleanCRT
423AC09 Status_ Fan Speed Text [DPT_16.001]Fan Speed Text14 Bytes16.1 Character String (ISO 8859-1)CRT
424AC09 Status_ AC Setpoint Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
425AC09 Status_ AC Ambient Reference Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
426AC09 Status_ Error/Alarm [DPT_1.005]0-No alarm;1-Alarm1 Bit1.5 alarmCRT
427AC09 Status_ Error Code [2-byte signed value]Error Code2 Bytes8.1 pulses differenceCRT
428AC09 Status_ Error Text [DPT_16.001]Error Text14 Bytes16.1 Character String (ISO 8859-1)CRT
429AC09 Status_ Control Mode No Central [DPT_1.002]1-NO CENTRAL mode is active1 Bit1.2 booleanCRT
430AC09 Status_ Control Mode LIFO [DPT_1.002]1-LIFO mode is active1 Bit1.2 booleanCRT
431AC09 Status_ Control Mode Central [DPT_1.002]1-CENTRAL mode is active1 Bit1.2 booleanCRT
432AC09 Status_ Control Mode Lock [DPT_1.002]1-LOCK mode is active1 Bit1.2 booleanCRT
433AC10 Control_ On/Off [DPT_1.001]0-Off;1-On1 Bit1.1 switchCW
434AC10 Control_ Operating Mode [DPT_20.102]0-Aut;1-Com;2-Stan;3-Eco;4-Pro1 Byte20.102 HVAC modeCW
435AC10 Control_ Mode [DPT_20.105]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 Byte20.105 HVAC control modeCW
436AC10 Control_ Mode Cool/Heat [DPT_1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCW
437AC10 Control_ Mode Auto [DPT_1.002]1-Set AUTO mode1 Bit1.2 booleanCW
438AC10 Control_ Mode Heat [DPT_1.002]1-Set HEAT mode1 Bit1.2 booleanCW
439AC10 Control_ Mode Cool [DPT_1.002]1-Set COOL mode1 Bit1.2 booleanCW
440AC10 Control_ Mode Fan [DPT_1.002]1-Set FAN mode1 Bit1.2 booleanCW
441AC10 Control_ Mode Dry [DPT_1.002]1-Set DRY mode1 Bit1.2 booleanCW
442AC10 Control_ Mode +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
442AC10 Control_ Mode +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
443AC10 Control_ Fan Speed [DPT_5.001]Thresholds: 50% and 83%1 Byte5.1 percentage (0..100%)CW
443AC10 Control_ Fan Speed [DPT_5.010]Speed values: 1,2,31 Byte5.10 counter pulses (0..255)CW
444AC10 Control_ Fan Speed Man/Auto [DPT_1.002]0-Manual;1-Auto1 Bit1.2 booleanCW
445AC10 Control_ Fan Speed 1 [DPT_1.002]1-Set Fan Speed 11 Bit1.2 booleanCW
446AC10 Control_ Fan Speed 2 [DPT_1.002]1-Set Fan Speed 21 Bit1.2 booleanCW
447AC10 Control_ Fan Speed 3 [DPT_1.002]1-Set Fan Speed 31 Bit1.2 booleanCW
448AC10 Control_ Fan Speed +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
448AC10 Control_ Fan Speed +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
449AC10 Control_ Setpoint Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
450AC10 Control_ Setpoint Temperature +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
450AC10 Control_ Setpoint Temperature +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
451AC10 Control_ Ambient Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
452AC10 Control_ Control Mode No Central [DPT_1.002]1-Set NO CENTRAL mode1 Bit1.2 booleanCW
453AC10 Control_ Control Mode LIFO [DPT_1.002]1-Set LIFO mode1 Bit1.2 booleanCW
454AC10 Control_ Control Mode Central [DPT_1.002]1-Set CENTRAL mode1 Bit1.2 booleanCW
455AC10 Control_ Control Mode Lock [DPT_1.002]1-Set LOCK mode1 Bit1.2 booleanCW
456AC10 Status_ On/Off [DPT_1.001]0-Off;1-On1 Bit1.1 switchCRT
457AC10 Status_ Operating Mode [DPT_20.102]0-Aut;1-Com;2-Stan;3-Eco;4-Pro1 Byte20.102 HVAC modeCRT
458AC10 Status_ Mode [DPT_20.105]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 Byte20.105 HVAC control modeCRT
459AC10 Status_ Mode Cool/Heat [DPT_1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCRT
460AC10 Status_ Mode Auto [DPT_1.002]1-AUTO mode is active1 Bit1.2 booleanCRT
461AC10 Status_ Mode Heat [DPT_1.002]1-HEAT mode is active1 Bit1.2 booleanCRT
462AC10 Status_ Mode Cool [DPT_1.002]1-COOL mode is active1 Bit1.2 booleanCRT
463AC10 Status_ Mode Fan [DPT_1.002]1-FAN mode is active1 Bit1.2 booleanCRT
464AC10 Status_ Mode Dry [DPT_1.002]1-DRY mode is active1 Bit1.2 booleanCRT
465AC10 Status_ Mode Text [DPT_16.001]Mode Text14 Bytes16.1 Character String (ISO 8859-1)CRT
466AC10 Status_ Fan Speed [DPT_5.001]33%, 66% and 100%1 Byte5.1 percentage (0..100%)CRT
466AC10 Status_ Fan Speed [DPT_5.010]Speed values: 1,2,31 Byte5.10 counter pulses (0..255)CRT
467AC10 Status_ Fan Speed Man/Auto [DPT_1.002]0-Manual;1-Auto1 Bit1.2 booleanCRT
468AC10 Status_ Fan Speed 1 [DPT_1.002]1-Fan in Speed 11 Bit1.2 booleanCRT
469AC10 Status_ Fan Speed 2 [DPT_1.002]1-Fan in Speed 21 Bit1.2 booleanCRT
470AC10 Status_ Fan Speed 3 [DPT_1.002]1-Fan in Speed 31 Bit1.2 booleanCRT
471AC10 Status_ Fan Speed Text [DPT_16.001]Fan Speed Text14 Bytes16.1 Character String (ISO 8859-1)CRT
472AC10 Status_ AC Setpoint Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
473AC10 Status_ AC Ambient Reference Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
474AC10 Status_ Error/Alarm [DPT_1.005]0-No alarm;1-Alarm1 Bit1.5 alarmCRT
475AC10 Status_ Error Code [2-byte signed value]Error Code2 Bytes8.1 pulses differenceCRT
476AC10 Status_ Error Text [DPT_16.001]Error Text14 Bytes16.1 Character String (ISO 8859-1)CRT
477AC10 Status_ Control Mode No Central [DPT_1.002]1-NO CENTRAL mode is active1 Bit1.2 booleanCRT
478AC10 Status_ Control Mode LIFO [DPT_1.002]1-LIFO mode is active1 Bit1.2 booleanCRT
479AC10 Status_ Control Mode Central [DPT_1.002]1-CENTRAL mode is active1 Bit1.2 booleanCRT
480AC10 Status_ Control Mode Lock [DPT_1.002]1-LOCK mode is active1 Bit1.2 booleanCRT
481AC11 Control_ On/Off [DPT_1.001]0-Off;1-On1 Bit1.1 switchCW
482AC11 Control_ Operating Mode [DPT_20.102]0-Aut;1-Com;2-Stan;3-Eco;4-Pro1 Byte20.102 HVAC modeCW
483AC11 Control_ Mode [DPT_20.105]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 Byte20.105 HVAC control modeCW
484AC11 Control_ Mode Cool/Heat [DPT_1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCW
485AC11 Control_ Mode Auto [DPT_1.002]1-Set AUTO mode1 Bit1.2 booleanCW
486AC11 Control_ Mode Heat [DPT_1.002]1-Set HEAT mode1 Bit1.2 booleanCW
487AC11 Control_ Mode Cool [DPT_1.002]1-Set COOL mode1 Bit1.2 booleanCW
488AC11 Control_ Mode Fan [DPT_1.002]1-Set FAN mode1 Bit1.2 booleanCW
489AC11 Control_ Mode Dry [DPT_1.002]1-Set DRY mode1 Bit1.2 booleanCW
490AC11 Control_ Mode +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
490AC11 Control_ Mode +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
491AC11 Control_ Fan Speed [DPT_5.001]Thresholds: 50% and 83%1 Byte5.1 percentage (0..100%)CW
491AC11 Control_ Fan Speed [DPT_5.010]Speed values: 1,2,31 Byte5.10 counter pulses (0..255)CW
492AC11 Control_ Fan Speed Man/Auto [DPT_1.002]0-Manual;1-Auto1 Bit1.2 booleanCW
493AC11 Control_ Fan Speed 1 [DPT_1.002]1-Set Fan Speed 11 Bit1.2 booleanCW
494AC11 Control_ Fan Speed 2 [DPT_1.002]1-Set Fan Speed 21 Bit1.2 booleanCW
495AC11 Control_ Fan Speed 3 [DPT_1.002]1-Set Fan Speed 31 Bit1.2 booleanCW
496AC11 Control_ Fan Speed +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
496AC11 Control_ Fan Speed +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
497AC11 Control_ Setpoint Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
498AC11 Control_ Setpoint Temperature +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
498AC11 Control_ Setpoint Temperature +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
499AC11 Control_ Ambient Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
500AC11 Control_ Control Mode No Central [DPT_1.002]1-Set NO CENTRAL mode1 Bit1.2 booleanCW
501AC11 Control_ Control Mode LIFO [DPT_1.002]1-Set LIFO mode1 Bit1.2 booleanCW
502AC11 Control_ Control Mode Central [DPT_1.002]1-Set CENTRAL mode1 Bit1.2 booleanCW
503AC11 Control_ Control Mode Lock [DPT_1.002]1-Set LOCK mode1 Bit1.2 booleanCW
504AC11 Status_ On/Off [DPT_1.001]0-Off;1-On1 Bit1.1 switchCRT
505AC11 Status_ Operating Mode [DPT_20.102]0-Aut;1-Com;2-Stan;3-Eco;4-Pro1 Byte20.102 HVAC modeCRT
506AC11 Status_ Mode [DPT_20.105]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 Byte20.105 HVAC control modeCRT
507AC11 Status_ Mode Cool/Heat [DPT_1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCRT
508AC11 Status_ Mode Auto [DPT_1.002]1-AUTO mode is active1 Bit1.2 booleanCRT
509AC11 Status_ Mode Heat [DPT_1.002]1-HEAT mode is active1 Bit1.2 booleanCRT
510AC11 Status_ Mode Cool [DPT_1.002]1-COOL mode is active1 Bit1.2 booleanCRT
511AC11 Status_ Mode Fan [DPT_1.002]1-FAN mode is active1 Bit1.2 booleanCRT
512AC11 Status_ Mode Dry [DPT_1.002]1-DRY mode is active1 Bit1.2 booleanCRT
513AC11 Status_ Mode Text [DPT_16.001]Mode Text14 Bytes16.1 Character String (ISO 8859-1)CRT
514AC11 Status_ Fan Speed [DPT_5.001]33%, 66% and 100%1 Byte5.1 percentage (0..100%)CRT
514AC11 Status_ Fan Speed [DPT_5.010]Speed values: 1,2,31 Byte5.10 counter pulses (0..255)CRT
515AC11 Status_ Fan Speed Man/Auto [DPT_1.002]0-Manual;1-Auto1 Bit1.2 booleanCRT
516AC11 Status_ Fan Speed 1 [DPT_1.002]1-Fan in Speed 11 Bit1.2 booleanCRT
517AC11 Status_ Fan Speed 2 [DPT_1.002]1-Fan in Speed 21 Bit1.2 booleanCRT
518AC11 Status_ Fan Speed 3 [DPT_1.002]1-Fan in Speed 31 Bit1.2 booleanCRT
519AC11 Status_ Fan Speed Text [DPT_16.001]Fan Speed Text14 Bytes16.1 Character String (ISO 8859-1)CRT
520AC11 Status_ AC Setpoint Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
521AC11 Status_ AC Ambient Reference Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
522AC11 Status_ Error/Alarm [DPT_1.005]0-No alarm;1-Alarm1 Bit1.5 alarmCRT
523AC11 Status_ Error Code [2-byte signed value]Error Code2 Bytes8.1 pulses differenceCRT
524AC11 Status_ Error Text [DPT_16.001]Error Text14 Bytes16.1 Character String (ISO 8859-1)CRT
525AC11 Status_ Control Mode No Central [DPT_1.002]1-NO CENTRAL mode is active1 Bit1.2 booleanCRT
526AC11 Status_ Control Mode LIFO [DPT_1.002]1-LIFO mode is active1 Bit1.2 booleanCRT
527AC11 Status_ Control Mode Central [DPT_1.002]1-CENTRAL mode is active1 Bit1.2 booleanCRT
528AC11 Status_ Control Mode Lock [DPT_1.002]1-LOCK mode is active1 Bit1.2 booleanCRT
529AC12 Control_ On/Off [DPT_1.001]0-Off;1-On1 Bit1.1 switchCW
530AC12 Control_ Operating Mode [DPT_20.102]0-Aut;1-Com;2-Stan;3-Eco;4-Pro1 Byte20.102 HVAC modeCW
531AC12 Control_ Mode [DPT_20.105]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 Byte20.105 HVAC control modeCW
532AC12 Control_ Mode Cool/Heat [DPT_1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCW
533AC12 Control_ Mode Auto [DPT_1.002]1-Set AUTO mode1 Bit1.2 booleanCW
534AC12 Control_ Mode Heat [DPT_1.002]1-Set HEAT mode1 Bit1.2 booleanCW
535AC12 Control_ Mode Cool [DPT_1.002]1-Set COOL mode1 Bit1.2 booleanCW
536AC12 Control_ Mode Fan [DPT_1.002]1-Set FAN mode1 Bit1.2 booleanCW
537AC12 Control_ Mode Dry [DPT_1.002]1-Set DRY mode1 Bit1.2 booleanCW
538AC12 Control_ Mode +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
538AC12 Control_ Mode +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
539AC12 Control_ Fan Speed [DPT_5.001]Thresholds: 50% and 83%1 Byte5.1 percentage (0..100%)CW
539AC12 Control_ Fan Speed [DPT_5.010]Speed values: 1,2,31 Byte5.10 counter pulses (0..255)CW
540AC12 Control_ Fan Speed Man/Auto [DPT_1.002]0-Manual;1-Auto1 Bit1.2 booleanCW
541AC12 Control_ Fan Speed 1 [DPT_1.002]1-Set Fan Speed 11 Bit1.2 booleanCW
542AC12 Control_ Fan Speed 2 [DPT_1.002]1-Set Fan Speed 21 Bit1.2 booleanCW
543AC12 Control_ Fan Speed 3 [DPT_1.002]1-Set Fan Speed 31 Bit1.2 booleanCW
544AC12 Control_ Fan Speed +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
544AC12 Control_ Fan Speed +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
545AC12 Control_ Setpoint Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
546AC12 Control_ Setpoint Temperature +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
546AC12 Control_ Setpoint Temperature +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
547AC12 Control_ Ambient Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
548AC12 Control_ Control Mode No Central [DPT_1.002]1-Set NO CENTRAL mode1 Bit1.2 booleanCW
549AC12 Control_ Control Mode LIFO [DPT_1.002]1-Set LIFO mode1 Bit1.2 booleanCW
550AC12 Control_ Control Mode Central [DPT_1.002]1-Set CENTRAL mode1 Bit1.2 booleanCW
551AC12 Control_ Control Mode Lock [DPT_1.002]1-Set LOCK mode1 Bit1.2 booleanCW
552AC12 Status_ On/Off [DPT_1.001]0-Off;1-On1 Bit1.1 switchCRT
553AC12 Status_ Operating Mode [DPT_20.102]0-Aut;1-Com;2-Stan;3-Eco;4-Pro1 Byte20.102 HVAC modeCRT
554AC12 Status_ Mode [DPT_20.105]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 Byte20.105 HVAC control modeCRT
555AC12 Status_ Mode Cool/Heat [DPT_1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCRT
556AC12 Status_ Mode Auto [DPT_1.002]1-AUTO mode is active1 Bit1.2 booleanCRT
557AC12 Status_ Mode Heat [DPT_1.002]1-HEAT mode is active1 Bit1.2 booleanCRT
558AC12 Status_ Mode Cool [DPT_1.002]1-COOL mode is active1 Bit1.2 booleanCRT
559AC12 Status_ Mode Fan [DPT_1.002]1-FAN mode is active1 Bit1.2 booleanCRT
560AC12 Status_ Mode Dry [DPT_1.002]1-DRY mode is active1 Bit1.2 booleanCRT
561AC12 Status_ Mode Text [DPT_16.001]Mode Text14 Bytes16.1 Character String (ISO 8859-1)CRT
562AC12 Status_ Fan Speed [DPT_5.001]33%, 66% and 100%1 Byte5.1 percentage (0..100%)CRT
562AC12 Status_ Fan Speed [DPT_5.010]Speed values: 1,2,31 Byte5.10 counter pulses (0..255)CRT
563AC12 Status_ Fan Speed Man/Auto [DPT_1.002]0-Manual;1-Auto1 Bit1.2 booleanCRT
564AC12 Status_ Fan Speed 1 [DPT_1.002]1-Fan in Speed 11 Bit1.2 booleanCRT
565AC12 Status_ Fan Speed 2 [DPT_1.002]1-Fan in Speed 21 Bit1.2 booleanCRT
566AC12 Status_ Fan Speed 3 [DPT_1.002]1-Fan in Speed 31 Bit1.2 booleanCRT
567AC12 Status_ Fan Speed Text [DPT_16.001]Fan Speed Text14 Bytes16.1 Character String (ISO 8859-1)CRT
568AC12 Status_ AC Setpoint Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
569AC12 Status_ AC Ambient Reference Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
570AC12 Status_ Error/Alarm [DPT_1.005]0-No alarm;1-Alarm1 Bit1.5 alarmCRT
571AC12 Status_ Error Code [2-byte signed value]Error Code2 Bytes8.1 pulses differenceCRT
572AC12 Status_ Error Text [DPT_16.001]Error Text14 Bytes16.1 Character String (ISO 8859-1)CRT
573AC12 Status_ Control Mode No Central [DPT_1.002]1-NO CENTRAL mode is active1 Bit1.2 booleanCRT
574AC12 Status_ Control Mode LIFO [DPT_1.002]1-LIFO mode is active1 Bit1.2 booleanCRT
575AC12 Status_ Control Mode Central [DPT_1.002]1-CENTRAL mode is active1 Bit1.2 booleanCRT
576AC12 Status_ Control Mode Lock [DPT_1.002]1-LOCK mode is active1 Bit1.2 booleanCRT
577AC13 Control_ On/Off [DPT_1.001]0-Off;1-On1 Bit1.1 switchCW
578AC13 Control_ Operating Mode [DPT_20.102]0-Aut;1-Com;2-Stan;3-Eco;4-Pro1 Byte20.102 HVAC modeCW
579AC13 Control_ Mode [DPT_20.105]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 Byte20.105 HVAC control modeCW
580AC13 Control_ Mode Cool/Heat [DPT_1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCW
581AC13 Control_ Mode Auto [DPT_1.002]1-Set AUTO mode1 Bit1.2 booleanCW
582AC13 Control_ Mode Heat [DPT_1.002]1-Set HEAT mode1 Bit1.2 booleanCW
583AC13 Control_ Mode Cool [DPT_1.002]1-Set COOL mode1 Bit1.2 booleanCW
584AC13 Control_ Mode Fan [DPT_1.002]1-Set FAN mode1 Bit1.2 booleanCW
585AC13 Control_ Mode Dry [DPT_1.002]1-Set DRY mode1 Bit1.2 booleanCW
586AC13 Control_ Mode +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
586AC13 Control_ Mode +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
587AC13 Control_ Fan Speed [DPT_5.001]Thresholds: 50% and 83%1 Byte5.1 percentage (0..100%)CW
587AC13 Control_ Fan Speed [DPT_5.010]Speed values: 1,2,31 Byte5.10 counter pulses (0..255)CW
588AC13 Control_ Fan Speed Man/Auto [DPT_1.002]0-Manual;1-Auto1 Bit1.2 booleanCW
589AC13 Control_ Fan Speed 1 [DPT_1.002]1-Set Fan Speed 11 Bit1.2 booleanCW
590AC13 Control_ Fan Speed 2 [DPT_1.002]1-Set Fan Speed 21 Bit1.2 booleanCW
591AC13 Control_ Fan Speed 3 [DPT_1.002]1-Set Fan Speed 31 Bit1.2 booleanCW
592AC13 Control_ Fan Speed +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
592AC13 Control_ Fan Speed +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
593AC13 Control_ Setpoint Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
594AC13 Control_ Setpoint Temperature +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
594AC13 Control_ Setpoint Temperature +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
595AC13 Control_ Ambient Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
596AC13 Control_ Control Mode No Central [DPT_1.002]1-Set NO CENTRAL mode1 Bit1.2 booleanCW
597AC13 Control_ Control Mode LIFO [DPT_1.002]1-Set LIFO mode1 Bit1.2 booleanCW
598AC13 Control_ Control Mode Central [DPT_1.002]1-Set CENTRAL mode1 Bit1.2 booleanCW
599AC13 Control_ Control Mode Lock [DPT_1.002]1-Set LOCK mode1 Bit1.2 booleanCW
600AC13 Status_ On/Off [DPT_1.001]0-Off;1-On1 Bit1.1 switchCRT
601AC13 Status_ Operating Mode [DPT_20.102]0-Aut;1-Com;2-Stan;3-Eco;4-Pro1 Byte20.102 HVAC modeCRT
602AC13 Status_ Mode [DPT_20.105]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 Byte20.105 HVAC control modeCRT
603AC13 Status_ Mode Cool/Heat [DPT_1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCRT
604AC13 Status_ Mode Auto [DPT_1.002]1-AUTO mode is active1 Bit1.2 booleanCRT
605AC13 Status_ Mode Heat [DPT_1.002]1-HEAT mode is active1 Bit1.2 booleanCRT
606AC13 Status_ Mode Cool [DPT_1.002]1-COOL mode is active1 Bit1.2 booleanCRT
607AC13 Status_ Mode Fan [DPT_1.002]1-FAN mode is active1 Bit1.2 booleanCRT
608AC13 Status_ Mode Dry [DPT_1.002]1-DRY mode is active1 Bit1.2 booleanCRT
609AC13 Status_ Mode Text [DPT_16.001]Mode Text14 Bytes16.1 Character String (ISO 8859-1)CRT
610AC13 Status_ Fan Speed [DPT_5.001]33%, 66% and 100%1 Byte5.1 percentage (0..100%)CRT
610AC13 Status_ Fan Speed [DPT_5.010]Speed values: 1,2,31 Byte5.10 counter pulses (0..255)CRT
611AC13 Status_ Fan Speed Man/Auto [DPT_1.002]0-Manual;1-Auto1 Bit1.2 booleanCRT
612AC13 Status_ Fan Speed 1 [DPT_1.002]1-Fan in Speed 11 Bit1.2 booleanCRT
613AC13 Status_ Fan Speed 2 [DPT_1.002]1-Fan in Speed 21 Bit1.2 booleanCRT
614AC13 Status_ Fan Speed 3 [DPT_1.002]1-Fan in Speed 31 Bit1.2 booleanCRT
615AC13 Status_ Fan Speed Text [DPT_16.001]Fan Speed Text14 Bytes16.1 Character String (ISO 8859-1)CRT
616AC13 Status_ AC Setpoint Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
617AC13 Status_ AC Ambient Reference Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
618AC13 Status_ Error/Alarm [DPT_1.005]0-No alarm;1-Alarm1 Bit1.5 alarmCRT
619AC13 Status_ Error Code [2-byte signed value]Error Code2 Bytes8.1 pulses differenceCRT
620AC13 Status_ Error Text [DPT_16.001]Error Text14 Bytes16.1 Character String (ISO 8859-1)CRT
621AC13 Status_ Control Mode No Central [DPT_1.002]1-NO CENTRAL mode is active1 Bit1.2 booleanCRT
622AC13 Status_ Control Mode LIFO [DPT_1.002]1-LIFO mode is active1 Bit1.2 booleanCRT
623AC13 Status_ Control Mode Central [DPT_1.002]1-CENTRAL mode is active1 Bit1.2 booleanCRT
624AC13 Status_ Control Mode Lock [DPT_1.002]1-LOCK mode is active1 Bit1.2 booleanCRT
625AC14 Control_ On/Off [DPT_1.001]0-Off;1-On1 Bit1.1 switchCW
626AC14 Control_ Operating Mode [DPT_20.102]0-Aut;1-Com;2-Stan;3-Eco;4-Pro1 Byte20.102 HVAC modeCW
627AC14 Control_ Mode [DPT_20.105]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 Byte20.105 HVAC control modeCW
628AC14 Control_ Mode Cool/Heat [DPT_1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCW
629AC14 Control_ Mode Auto [DPT_1.002]1-Set AUTO mode1 Bit1.2 booleanCW
630AC14 Control_ Mode Heat [DPT_1.002]1-Set HEAT mode1 Bit1.2 booleanCW
631AC14 Control_ Mode Cool [DPT_1.002]1-Set COOL mode1 Bit1.2 booleanCW
632AC14 Control_ Mode Fan [DPT_1.002]1-Set FAN mode1 Bit1.2 booleanCW
633AC14 Control_ Mode Dry [DPT_1.002]1-Set DRY mode1 Bit1.2 booleanCW
634AC14 Control_ Mode +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
634AC14 Control_ Mode +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
635AC14 Control_ Fan Speed [DPT_5.001]Thresholds: 50% and 83%1 Byte5.1 percentage (0..100%)CW
635AC14 Control_ Fan Speed [DPT_5.010]Speed values: 1,2,31 Byte5.10 counter pulses (0..255)CW
636AC14 Control_ Fan Speed Man/Auto [DPT_1.002]0-Manual;1-Auto1 Bit1.2 booleanCW
637AC14 Control_ Fan Speed 1 [DPT_1.002]1-Set Fan Speed 11 Bit1.2 booleanCW
638AC14 Control_ Fan Speed 2 [DPT_1.002]1-Set Fan Speed 21 Bit1.2 booleanCW
639AC14 Control_ Fan Speed 3 [DPT_1.002]1-Set Fan Speed 31 Bit1.2 booleanCW
640AC14 Control_ Fan Speed +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
640AC14 Control_ Fan Speed +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
641AC14 Control_ Setpoint Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
642AC14 Control_ Setpoint Temperature +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
642AC14 Control_ Setpoint Temperature +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
643AC14 Control_ Ambient Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
644AC14 Control_ Control Mode No Central [DPT_1.002]1-Set NO CENTRAL mode1 Bit1.2 booleanCW
645AC14 Control_ Control Mode LIFO [DPT_1.002]1-Set LIFO mode1 Bit1.2 booleanCW
646AC14 Control_ Control Mode Central [DPT_1.002]1-Set CENTRAL mode1 Bit1.2 booleanCW
647AC14 Control_ Control Mode Lock [DPT_1.002]1-Set LOCK mode1 Bit1.2 booleanCW
648AC14 Status_ On/Off [DPT_1.001]0-Off;1-On1 Bit1.1 switchCRT
649AC14 Status_ Operating Mode [DPT_20.102]0-Aut;1-Com;2-Stan;3-Eco;4-Pro1 Byte20.102 HVAC modeCRT
650AC14 Status_ Mode [DPT_20.105]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 Byte20.105 HVAC control modeCRT
651AC14 Status_ Mode Cool/Heat [DPT_1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCRT
652AC14 Status_ Mode Auto [DPT_1.002]1-AUTO mode is active1 Bit1.2 booleanCRT
653AC14 Status_ Mode Heat [DPT_1.002]1-HEAT mode is active1 Bit1.2 booleanCRT
654AC14 Status_ Mode Cool [DPT_1.002]1-COOL mode is active1 Bit1.2 booleanCRT
655AC14 Status_ Mode Fan [DPT_1.002]1-FAN mode is active1 Bit1.2 booleanCRT
656AC14 Status_ Mode Dry [DPT_1.002]1-DRY mode is active1 Bit1.2 booleanCRT
657AC14 Status_ Mode Text [DPT_16.001]Mode Text14 Bytes16.1 Character String (ISO 8859-1)CRT
658AC14 Status_ Fan Speed [DPT_5.001]33%, 66% and 100%1 Byte5.1 percentage (0..100%)CRT
658AC14 Status_ Fan Speed [DPT_5.010]Speed values: 1,2,31 Byte5.10 counter pulses (0..255)CRT
659AC14 Status_ Fan Speed Man/Auto [DPT_1.002]0-Manual;1-Auto1 Bit1.2 booleanCRT
660AC14 Status_ Fan Speed 1 [DPT_1.002]1-Fan in Speed 11 Bit1.2 booleanCRT
661AC14 Status_ Fan Speed 2 [DPT_1.002]1-Fan in Speed 21 Bit1.2 booleanCRT
662AC14 Status_ Fan Speed 3 [DPT_1.002]1-Fan in Speed 31 Bit1.2 booleanCRT
663AC14 Status_ Fan Speed Text [DPT_16.001]Fan Speed Text14 Bytes16.1 Character String (ISO 8859-1)CRT
664AC14 Status_ AC Setpoint Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
665AC14 Status_ AC Ambient Reference Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
666AC14 Status_ Error/Alarm [DPT_1.005]0-No alarm;1-Alarm1 Bit1.5 alarmCRT
667AC14 Status_ Error Code [2-byte signed value]Error Code2 Bytes8.1 pulses differenceCRT
668AC14 Status_ Error Text [DPT_16.001]Error Text14 Bytes16.1 Character String (ISO 8859-1)CRT
669AC14 Status_ Control Mode No Central [DPT_1.002]1-NO CENTRAL mode is active1 Bit1.2 booleanCRT
670AC14 Status_ Control Mode LIFO [DPT_1.002]1-LIFO mode is active1 Bit1.2 booleanCRT
671AC14 Status_ Control Mode Central [DPT_1.002]1-CENTRAL mode is active1 Bit1.2 booleanCRT
672AC14 Status_ Control Mode Lock [DPT_1.002]1-LOCK mode is active1 Bit1.2 booleanCRT
673AC15 Control_ On/Off [DPT_1.001]0-Off;1-On1 Bit1.1 switchCW
674AC15 Control_ Operating Mode [DPT_20.102]0-Aut;1-Com;2-Stan;3-Eco;4-Pro1 Byte20.102 HVAC modeCW
675AC15 Control_ Mode [DPT_20.105]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 Byte20.105 HVAC control modeCW
676AC15 Control_ Mode Cool/Heat [DPT_1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCW
677AC15 Control_ Mode Auto [DPT_1.002]1-Set AUTO mode1 Bit1.2 booleanCW
678AC15 Control_ Mode Heat [DPT_1.002]1-Set HEAT mode1 Bit1.2 booleanCW
679AC15 Control_ Mode Cool [DPT_1.002]1-Set COOL mode1 Bit1.2 booleanCW
680AC15 Control_ Mode Fan [DPT_1.002]1-Set FAN mode1 Bit1.2 booleanCW
681AC15 Control_ Mode Dry [DPT_1.002]1-Set DRY mode1 Bit1.2 booleanCW
682AC15 Control_ Mode +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
682AC15 Control_ Mode +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
683AC15 Control_ Fan Speed [DPT_5.001]Thresholds: 50% and 83%1 Byte5.1 percentage (0..100%)CW
683AC15 Control_ Fan Speed [DPT_5.010]Speed values: 1,2,31 Byte5.10 counter pulses (0..255)CW
684AC15 Control_ Fan Speed Man/Auto [DPT_1.002]0-Manual;1-Auto1 Bit1.2 booleanCW
685AC15 Control_ Fan Speed 1 [DPT_1.002]1-Set Fan Speed 11 Bit1.2 booleanCW
686AC15 Control_ Fan Speed 2 [DPT_1.002]1-Set Fan Speed 21 Bit1.2 booleanCW
687AC15 Control_ Fan Speed 3 [DPT_1.002]1-Set Fan Speed 31 Bit1.2 booleanCW
688AC15 Control_ Fan Speed +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
688AC15 Control_ Fan Speed +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
689AC15 Control_ Setpoint Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
690AC15 Control_ Setpoint Temperature +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
690AC15 Control_ Setpoint Temperature +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
691AC15 Control_ Ambient Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
692AC15 Control_ Control Mode No Central [DPT_1.002]1-Set NO CENTRAL mode1 Bit1.2 booleanCW
693AC15 Control_ Control Mode LIFO [DPT_1.002]1-Set LIFO mode1 Bit1.2 booleanCW
694AC15 Control_ Control Mode Central [DPT_1.002]1-Set CENTRAL mode1 Bit1.2 booleanCW
695AC15 Control_ Control Mode Lock [DPT_1.002]1-Set LOCK mode1 Bit1.2 booleanCW
696AC15 Status_ On/Off [DPT_1.001]0-Off;1-On1 Bit1.1 switchCRT
697AC15 Status_ Operating Mode [DPT_20.102]0-Aut;1-Com;2-Stan;3-Eco;4-Pro1 Byte20.102 HVAC modeCRT
698AC15 Status_ Mode [DPT_20.105]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 Byte20.105 HVAC control modeCRT
699AC15 Status_ Mode Cool/Heat [DPT_1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCRT
700AC15 Status_ Mode Auto [DPT_1.002]1-AUTO mode is active1 Bit1.2 booleanCRT
701AC15 Status_ Mode Heat [DPT_1.002]1-HEAT mode is active1 Bit1.2 booleanCRT
702AC15 Status_ Mode Cool [DPT_1.002]1-COOL mode is active1 Bit1.2 booleanCRT
703AC15 Status_ Mode Fan [DPT_1.002]1-FAN mode is active1 Bit1.2 booleanCRT
704AC15 Status_ Mode Dry [DPT_1.002]1-DRY mode is active1 Bit1.2 booleanCRT
705AC15 Status_ Mode Text [DPT_16.001]Mode Text14 Bytes16.1 Character String (ISO 8859-1)CRT
706AC15 Status_ Fan Speed [DPT_5.001]33%, 66% and 100%1 Byte5.1 percentage (0..100%)CRT
706AC15 Status_ Fan Speed [DPT_5.010]Speed values: 1,2,31 Byte5.10 counter pulses (0..255)CRT
707AC15 Status_ Fan Speed Man/Auto [DPT_1.002]0-Manual;1-Auto1 Bit1.2 booleanCRT
708AC15 Status_ Fan Speed 1 [DPT_1.002]1-Fan in Speed 11 Bit1.2 booleanCRT
709AC15 Status_ Fan Speed 2 [DPT_1.002]1-Fan in Speed 21 Bit1.2 booleanCRT
710AC15 Status_ Fan Speed 3 [DPT_1.002]1-Fan in Speed 31 Bit1.2 booleanCRT
711AC15 Status_ Fan Speed Text [DPT_16.001]Fan Speed Text14 Bytes16.1 Character String (ISO 8859-1)CRT
712AC15 Status_ AC Setpoint Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
713AC15 Status_ AC Ambient Reference Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
714AC15 Status_ Error/Alarm [DPT_1.005]0-No alarm;1-Alarm1 Bit1.5 alarmCRT
715AC15 Status_ Error Code [2-byte signed value]Error Code2 Bytes8.1 pulses differenceCRT
716AC15 Status_ Error Text [DPT_16.001]Error Text14 Bytes16.1 Character String (ISO 8859-1)CRT
717AC15 Status_ Control Mode No Central [DPT_1.002]1-NO CENTRAL mode is active1 Bit1.2 booleanCRT
718AC15 Status_ Control Mode LIFO [DPT_1.002]1-LIFO mode is active1 Bit1.2 booleanCRT
719AC15 Status_ Control Mode Central [DPT_1.002]1-CENTRAL mode is active1 Bit1.2 booleanCRT
720AC15 Status_ Control Mode Lock [DPT_1.002]1-LOCK mode is active1 Bit1.2 booleanCRT
721AC16 Control_ On/Off [DPT_1.001]0-Off;1-On1 Bit1.1 switchCW
722AC16 Control_ Operating Mode [DPT_20.102]0-Aut;1-Com;2-Stan;3-Eco;4-Pro1 Byte20.102 HVAC modeCW
723AC16 Control_ Mode [DPT_20.105]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 Byte20.105 HVAC control modeCW
724AC16 Control_ Mode Cool/Heat [DPT_1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCW
725AC16 Control_ Mode Auto [DPT_1.002]1-Set AUTO mode1 Bit1.2 booleanCW
726AC16 Control_ Mode Heat [DPT_1.002]1-Set HEAT mode1 Bit1.2 booleanCW
727AC16 Control_ Mode Cool [DPT_1.002]1-Set COOL mode1 Bit1.2 booleanCW
728AC16 Control_ Mode Fan [DPT_1.002]1-Set FAN mode1 Bit1.2 booleanCW
729AC16 Control_ Mode Dry [DPT_1.002]1-Set DRY mode1 Bit1.2 booleanCW
730AC16 Control_ Mode +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
730AC16 Control_ Mode +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
731AC16 Control_ Fan Speed [DPT_5.001]Thresholds: 50% and 83%1 Byte5.1 percentage (0..100%)CW
731AC16 Control_ Fan Speed [DPT_5.010]Speed values: 1,2,31 Byte5.10 counter pulses (0..255)CW
732AC16 Control_ Fan Speed Man/Auto [DPT_1.002]0-Manual;1-Auto1 Bit1.2 booleanCW
733AC16 Control_ Fan Speed 1 [DPT_1.002]1-Set Fan Speed 11 Bit1.2 booleanCW
734AC16 Control_ Fan Speed 2 [DPT_1.002]1-Set Fan Speed 21 Bit1.2 booleanCW
735AC16 Control_ Fan Speed 3 [DPT_1.002]1-Set Fan Speed 31 Bit1.2 booleanCW
736AC16 Control_ Fan Speed +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
736AC16 Control_ Fan Speed +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
737AC16 Control_ Setpoint Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
738AC16 Control_ Setpoint Temperature +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
738AC16 Control_ Setpoint Temperature +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
739AC16 Control_ Ambient Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
740AC16 Control_ Control Mode No Central [DPT_1.002]1-Set NO CENTRAL mode1 Bit1.2 booleanCW
741AC16 Control_ Control Mode LIFO [DPT_1.002]1-Set LIFO mode1 Bit1.2 booleanCW
742AC16 Control_ Control Mode Central [DPT_1.002]1-Set CENTRAL mode1 Bit1.2 booleanCW
743AC16 Control_ Control Mode Lock [DPT_1.002]1-Set LOCK mode1 Bit1.2 booleanCW
744AC16 Status_ On/Off [DPT_1.001]0-Off;1-On1 Bit1.1 switchCRT
745AC16 Status_ Operating Mode [DPT_20.102]0-Aut;1-Com;2-Stan;3-Eco;4-Pro1 Byte20.102 HVAC modeCRT
746AC16 Status_ Mode [DPT_20.105]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 Byte20.105 HVAC control modeCRT
747AC16 Status_ Mode Cool/Heat [DPT_1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCRT
748AC16 Status_ Mode Auto [DPT_1.002]1-AUTO mode is active1 Bit1.2 booleanCRT
749AC16 Status_ Mode Heat [DPT_1.002]1-HEAT mode is active1 Bit1.2 booleanCRT
750AC16 Status_ Mode Cool [DPT_1.002]1-COOL mode is active1 Bit1.2 booleanCRT
751AC16 Status_ Mode Fan [DPT_1.002]1-FAN mode is active1 Bit1.2 booleanCRT
752AC16 Status_ Mode Dry [DPT_1.002]1-DRY mode is active1 Bit1.2 booleanCRT
753AC16 Status_ Mode Text [DPT_16.001]Mode Text14 Bytes16.1 Character String (ISO 8859-1)CRT
754AC16 Status_ Fan Speed [DPT_5.001]33%, 66% and 100%1 Byte5.1 percentage (0..100%)CRT
754AC16 Status_ Fan Speed [DPT_5.010]Speed values: 1,2,31 Byte5.10 counter pulses (0..255)CRT
755AC16 Status_ Fan Speed Man/Auto [DPT_1.002]0-Manual;1-Auto1 Bit1.2 booleanCRT
756AC16 Status_ Fan Speed 1 [DPT_1.002]1-Fan in Speed 11 Bit1.2 booleanCRT
757AC16 Status_ Fan Speed 2 [DPT_1.002]1-Fan in Speed 21 Bit1.2 booleanCRT
758AC16 Status_ Fan Speed 3 [DPT_1.002]1-Fan in Speed 31 Bit1.2 booleanCRT
759AC16 Status_ Fan Speed Text [DPT_16.001]Fan Speed Text14 Bytes16.1 Character String (ISO 8859-1)CRT
760AC16 Status_ AC Setpoint Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
761AC16 Status_ AC Ambient Reference Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
762AC16 Status_ Error/Alarm [DPT_1.005]0-No alarm;1-Alarm1 Bit1.5 alarmCRT
763AC16 Status_ Error Code [2-byte signed value]Error Code2 Bytes8.1 pulses differenceCRT
764AC16 Status_ Error Text [DPT_16.001]Error Text14 Bytes16.1 Character String (ISO 8859-1)CRT
765AC16 Status_ Control Mode No Central [DPT_1.002]1-NO CENTRAL mode is active1 Bit1.2 booleanCRT
766AC16 Status_ Control Mode LIFO [DPT_1.002]1-LIFO mode is active1 Bit1.2 booleanCRT
767AC16 Status_ Control Mode Central [DPT_1.002]1-CENTRAL mode is active1 Bit1.2 booleanCRT
768AC16 Status_ Control Mode Lock [DPT_1.002]1-LOCK mode is active1 Bit1.2 booleanCRT
769AC17 Control_ On/Off [DPT_1.001]0-Off;1-On1 Bit1.1 switchCW
770AC17 Control_ Operating Mode [DPT_20.102]0-Aut;1-Com;2-Stan;3-Eco;4-Pro1 Byte20.102 HVAC modeCW
771AC17 Control_ Mode [DPT_20.105]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 Byte20.105 HVAC control modeCW
772AC17 Control_ Mode Cool/Heat [DPT_1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCW
773AC17 Control_ Mode Auto [DPT_1.002]1-Set AUTO mode1 Bit1.2 booleanCW
774AC17 Control_ Mode Heat [DPT_1.002]1-Set HEAT mode1 Bit1.2 booleanCW
775AC17 Control_ Mode Cool [DPT_1.002]1-Set COOL mode1 Bit1.2 booleanCW
776AC17 Control_ Mode Fan [DPT_1.002]1-Set FAN mode1 Bit1.2 booleanCW
777AC17 Control_ Mode Dry [DPT_1.002]1-Set DRY mode1 Bit1.2 booleanCW
778AC17 Control_ Mode +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
778AC17 Control_ Mode +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
779AC17 Control_ Fan Speed [DPT_5.001]Thresholds: 50% and 83%1 Byte5.1 percentage (0..100%)CW
779AC17 Control_ Fan Speed [DPT_5.010]Speed values: 1,2,31 Byte5.10 counter pulses (0..255)CW
780AC17 Control_ Fan Speed Man/Auto [DPT_1.002]0-Manual;1-Auto1 Bit1.2 booleanCW
781AC17 Control_ Fan Speed 1 [DPT_1.002]1-Set Fan Speed 11 Bit1.2 booleanCW
782AC17 Control_ Fan Speed 2 [DPT_1.002]1-Set Fan Speed 21 Bit1.2 booleanCW
783AC17 Control_ Fan Speed 3 [DPT_1.002]1-Set Fan Speed 31 Bit1.2 booleanCW
784AC17 Control_ Fan Speed +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
784AC17 Control_ Fan Speed +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
785AC17 Control_ Setpoint Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
786AC17 Control_ Setpoint Temperature +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
786AC17 Control_ Setpoint Temperature +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
787AC17 Control_ Ambient Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
788AC17 Control_ Control Mode No Central [DPT_1.002]1-Set NO CENTRAL mode1 Bit1.2 booleanCW
789AC17 Control_ Control Mode LIFO [DPT_1.002]1-Set LIFO mode1 Bit1.2 booleanCW
790AC17 Control_ Control Mode Central [DPT_1.002]1-Set CENTRAL mode1 Bit1.2 booleanCW
791AC17 Control_ Control Mode Lock [DPT_1.002]1-Set LOCK mode1 Bit1.2 booleanCW
792AC17 Status_ On/Off [DPT_1.001]0-Off;1-On1 Bit1.1 switchCRT
793AC17 Status_ Operating Mode [DPT_20.102]0-Aut;1-Com;2-Stan;3-Eco;4-Pro1 Byte20.102 HVAC modeCRT
794AC17 Status_ Mode [DPT_20.105]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 Byte20.105 HVAC control modeCRT
795AC17 Status_ Mode Cool/Heat [DPT_1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCRT
796AC17 Status_ Mode Auto [DPT_1.002]1-AUTO mode is active1 Bit1.2 booleanCRT
797AC17 Status_ Mode Heat [DPT_1.002]1-HEAT mode is active1 Bit1.2 booleanCRT
798AC17 Status_ Mode Cool [DPT_1.002]1-COOL mode is active1 Bit1.2 booleanCRT
799AC17 Status_ Mode Fan [DPT_1.002]1-FAN mode is active1 Bit1.2 booleanCRT
800AC17 Status_ Mode Dry [DPT_1.002]1-DRY mode is active1 Bit1.2 booleanCRT
801AC17 Status_ Mode Text [DPT_16.001]Mode Text14 Bytes16.1 Character String (ISO 8859-1)CRT
802AC17 Status_ Fan Speed [DPT_5.001]33%, 66% and 100%1 Byte5.1 percentage (0..100%)CRT
802AC17 Status_ Fan Speed [DPT_5.010]Speed values: 1,2,31 Byte5.10 counter pulses (0..255)CRT
803AC17 Status_ Fan Speed Man/Auto [DPT_1.002]0-Manual;1-Auto1 Bit1.2 booleanCRT
804AC17 Status_ Fan Speed 1 [DPT_1.002]1-Fan in Speed 11 Bit1.2 booleanCRT
805AC17 Status_ Fan Speed 2 [DPT_1.002]1-Fan in Speed 21 Bit1.2 booleanCRT
806AC17 Status_ Fan Speed 3 [DPT_1.002]1-Fan in Speed 31 Bit1.2 booleanCRT
807AC17 Status_ Fan Speed Text [DPT_16.001]Fan Speed Text14 Bytes16.1 Character String (ISO 8859-1)CRT
808AC17 Status_ AC Setpoint Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
809AC17 Status_ AC Ambient Reference Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
810AC17 Status_ Error/Alarm [DPT_1.005]0-No alarm;1-Alarm1 Bit1.5 alarmCRT
811AC17 Status_ Error Code [2-byte signed value]Error Code2 Bytes8.1 pulses differenceCRT
812AC17 Status_ Error Text [DPT_16.001]Error Text14 Bytes16.1 Character String (ISO 8859-1)CRT
813AC17 Status_ Control Mode No Central [DPT_1.002]1-NO CENTRAL mode is active1 Bit1.2 booleanCRT
814AC17 Status_ Control Mode LIFO [DPT_1.002]1-LIFO mode is active1 Bit1.2 booleanCRT
815AC17 Status_ Control Mode Central [DPT_1.002]1-CENTRAL mode is active1 Bit1.2 booleanCRT
816AC17 Status_ Control Mode Lock [DPT_1.002]1-LOCK mode is active1 Bit1.2 booleanCRT
817AC18 Control_ On/Off [DPT_1.001]0-Off;1-On1 Bit1.1 switchCW
818AC18 Control_ Operating Mode [DPT_20.102]0-Aut;1-Com;2-Stan;3-Eco;4-Pro1 Byte20.102 HVAC modeCW
819AC18 Control_ Mode [DPT_20.105]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 Byte20.105 HVAC control modeCW
820AC18 Control_ Mode Cool/Heat [DPT_1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCW
821AC18 Control_ Mode Auto [DPT_1.002]1-Set AUTO mode1 Bit1.2 booleanCW
822AC18 Control_ Mode Heat [DPT_1.002]1-Set HEAT mode1 Bit1.2 booleanCW
823AC18 Control_ Mode Cool [DPT_1.002]1-Set COOL mode1 Bit1.2 booleanCW
824AC18 Control_ Mode Fan [DPT_1.002]1-Set FAN mode1 Bit1.2 booleanCW
825AC18 Control_ Mode Dry [DPT_1.002]1-Set DRY mode1 Bit1.2 booleanCW
826AC18 Control_ Mode +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
826AC18 Control_ Mode +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
827AC18 Control_ Fan Speed [DPT_5.001]Thresholds: 50% and 83%1 Byte5.1 percentage (0..100%)CW
827AC18 Control_ Fan Speed [DPT_5.010]Speed values: 1,2,31 Byte5.10 counter pulses (0..255)CW
828AC18 Control_ Fan Speed Man/Auto [DPT_1.002]0-Manual;1-Auto1 Bit1.2 booleanCW
829AC18 Control_ Fan Speed 1 [DPT_1.002]1-Set Fan Speed 11 Bit1.2 booleanCW
830AC18 Control_ Fan Speed 2 [DPT_1.002]1-Set Fan Speed 21 Bit1.2 booleanCW
831AC18 Control_ Fan Speed 3 [DPT_1.002]1-Set Fan Speed 31 Bit1.2 booleanCW
832AC18 Control_ Fan Speed +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
832AC18 Control_ Fan Speed +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
833AC18 Control_ Setpoint Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
834AC18 Control_ Setpoint Temperature +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
834AC18 Control_ Setpoint Temperature +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
835AC18 Control_ Ambient Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
836AC18 Control_ Control Mode No Central [DPT_1.002]1-Set NO CENTRAL mode1 Bit1.2 booleanCW
837AC18 Control_ Control Mode LIFO [DPT_1.002]1-Set LIFO mode1 Bit1.2 booleanCW
838AC18 Control_ Control Mode Central [DPT_1.002]1-Set CENTRAL mode1 Bit1.2 booleanCW
839AC18 Control_ Control Mode Lock [DPT_1.002]1-Set LOCK mode1 Bit1.2 booleanCW
840AC18 Status_ On/Off [DPT_1.001]0-Off;1-On1 Bit1.1 switchCRT
841AC18 Status_ Operating Mode [DPT_20.102]0-Aut;1-Com;2-Stan;3-Eco;4-Pro1 Byte20.102 HVAC modeCRT
842AC18 Status_ Mode [DPT_20.105]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 Byte20.105 HVAC control modeCRT
843AC18 Status_ Mode Cool/Heat [DPT_1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCRT
844AC18 Status_ Mode Auto [DPT_1.002]1-AUTO mode is active1 Bit1.2 booleanCRT
845AC18 Status_ Mode Heat [DPT_1.002]1-HEAT mode is active1 Bit1.2 booleanCRT
846AC18 Status_ Mode Cool [DPT_1.002]1-COOL mode is active1 Bit1.2 booleanCRT
847AC18 Status_ Mode Fan [DPT_1.002]1-FAN mode is active1 Bit1.2 booleanCRT
848AC18 Status_ Mode Dry [DPT_1.002]1-DRY mode is active1 Bit1.2 booleanCRT
849AC18 Status_ Mode Text [DPT_16.001]Mode Text14 Bytes16.1 Character String (ISO 8859-1)CRT
850AC18 Status_ Fan Speed [DPT_5.001]33%, 66% and 100%1 Byte5.1 percentage (0..100%)CRT
850AC18 Status_ Fan Speed [DPT_5.010]Speed values: 1,2,31 Byte5.10 counter pulses (0..255)CRT
851AC18 Status_ Fan Speed Man/Auto [DPT_1.002]0-Manual;1-Auto1 Bit1.2 booleanCRT
852AC18 Status_ Fan Speed 1 [DPT_1.002]1-Fan in Speed 11 Bit1.2 booleanCRT
853AC18 Status_ Fan Speed 2 [DPT_1.002]1-Fan in Speed 21 Bit1.2 booleanCRT
854AC18 Status_ Fan Speed 3 [DPT_1.002]1-Fan in Speed 31 Bit1.2 booleanCRT
855AC18 Status_ Fan Speed Text [DPT_16.001]Fan Speed Text14 Bytes16.1 Character String (ISO 8859-1)CRT
856AC18 Status_ AC Setpoint Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
857AC18 Status_ AC Ambient Reference Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
858AC18 Status_ Error/Alarm [DPT_1.005]0-No alarm;1-Alarm1 Bit1.5 alarmCRT
859AC18 Status_ Error Code [2-byte signed value]Error Code2 Bytes8.1 pulses differenceCRT
860AC18 Status_ Error Text [DPT_16.001]Error Text14 Bytes16.1 Character String (ISO 8859-1)CRT
861AC18 Status_ Control Mode No Central [DPT_1.002]1-NO CENTRAL mode is active1 Bit1.2 booleanCRT
862AC18 Status_ Control Mode LIFO [DPT_1.002]1-LIFO mode is active1 Bit1.2 booleanCRT
863AC18 Status_ Control Mode Central [DPT_1.002]1-CENTRAL mode is active1 Bit1.2 booleanCRT
864AC18 Status_ Control Mode Lock [DPT_1.002]1-LOCK mode is active1 Bit1.2 booleanCRT
865AC19 Control_ On/Off [DPT_1.001]0-Off;1-On1 Bit1.1 switchCW
866AC19 Control_ Operating Mode [DPT_20.102]0-Aut;1-Com;2-Stan;3-Eco;4-Pro1 Byte20.102 HVAC modeCW
867AC19 Control_ Mode [DPT_20.105]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 Byte20.105 HVAC control modeCW
868AC19 Control_ Mode Cool/Heat [DPT_1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCW
869AC19 Control_ Mode Auto [DPT_1.002]1-Set AUTO mode1 Bit1.2 booleanCW
870AC19 Control_ Mode Heat [DPT_1.002]1-Set HEAT mode1 Bit1.2 booleanCW
871AC19 Control_ Mode Cool [DPT_1.002]1-Set COOL mode1 Bit1.2 booleanCW
872AC19 Control_ Mode Fan [DPT_1.002]1-Set FAN mode1 Bit1.2 booleanCW
873AC19 Control_ Mode Dry [DPT_1.002]1-Set DRY mode1 Bit1.2 booleanCW
874AC19 Control_ Mode +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
874AC19 Control_ Mode +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
875AC19 Control_ Fan Speed [DPT_5.001]Thresholds: 50% and 83%1 Byte5.1 percentage (0..100%)CW
875AC19 Control_ Fan Speed [DPT_5.010]Speed values: 1,2,31 Byte5.10 counter pulses (0..255)CW
876AC19 Control_ Fan Speed Man/Auto [DPT_1.002]0-Manual;1-Auto1 Bit1.2 booleanCW
877AC19 Control_ Fan Speed 1 [DPT_1.002]1-Set Fan Speed 11 Bit1.2 booleanCW
878AC19 Control_ Fan Speed 2 [DPT_1.002]1-Set Fan Speed 21 Bit1.2 booleanCW
879AC19 Control_ Fan Speed 3 [DPT_1.002]1-Set Fan Speed 31 Bit1.2 booleanCW
880AC19 Control_ Fan Speed +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
880AC19 Control_ Fan Speed +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
881AC19 Control_ Setpoint Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
882AC19 Control_ Setpoint Temperature +/- [DPT_1.007]0-Dec.;1-Inc.1 Bit1.7 stepCW
882AC19 Control_ Setpoint Temperature +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
883AC19 Control_ Ambient Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
884AC19 Control_ Control Mode No Central [DPT_1.002]1-Set NO CENTRAL mode1 Bit1.2 booleanCW
885AC19 Control_ Control Mode LIFO [DPT_1.002]1-Set LIFO mode1 Bit1.2 booleanCW
886AC19 Control_ Control Mode Central [DPT_1.002]1-Set CENTRAL mode1 Bit1.2 booleanCW
887AC19 Control_ Control Mode Lock [DPT_1.002]1-Set LOCK mode1 Bit1.2 booleanCW
888AC19 Status_ On/Off [DPT_1.001]0-Off;1-On1 Bit1.1 switchCRT
889AC19 Status_ Operating Mode [DPT_20.102]0-Aut;1-Com;2-Stan;3-Eco;4-Pro1 Byte20.102 HVAC modeCRT
890AC19 Status_ Mode [DPT_20.105]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 Byte20.105 HVAC control modeCRT
891AC19 Status_ Mode Cool/Heat [DPT_1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCRT
892AC19 Status_ Mode Auto [DPT_1.002]1-AUTO mode is active1 Bit1.2 booleanCRT
893AC19 Status_ Mode Heat [DPT_1.002]1-HEAT mode is active1 Bit1.2 booleanCRT
894AC19 Status_ Mode Cool [DPT_1.002]1-COOL mode is active1 Bit1.2 booleanCRT
895AC19 Status_ Mode Fan [DPT_1.002]1-FAN mode is active1 Bit1.2 booleanCRT
896AC19 Status_ Mode Dry [DPT_1.002]1-DRY mode is active1 Bit1.2 booleanCRT
897AC19 Status_ Mode Text [DPT_16.001]Mode Text14 Bytes16.1 Character String (ISO 8859-1)CRT
898AC19 Status_ Fan Speed [DPT_5.001]33%, 66% and 100%1 Byte5.1 percentage (0..100%)CRT
898AC19 Status_ Fan Speed [DPT_5.010]Speed values: 1,2,31 Byte5.10 counter pulses (0..255)CRT
899AC19 Status_ Fan Speed Man/Auto [DPT_1.002]0-Manual;1-Auto1 Bit1.2 booleanCRT
900AC19 Status_ Fan Speed 1 [DPT_1.002]1-Fan in Speed 11 Bit1.2 booleanCRT
901AC19 Status_ Fan Speed 2 [DPT_1.002]1-Fan in Speed 21 Bit1.2 booleanCRT
902AC19 Status_ Fan Speed 3 [DPT_1.002]1-Fan in Speed 31 Bit1.2 booleanCRT
903AC19 Status_ Fan Speed Text [DPT_16.001]Fan Speed Text14 Bytes16.1 Character String (ISO 8859-1)CRT
904AC19 Status_ AC Setpoint Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
905AC19 Status_ AC Ambient Reference Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT

First 1000 of 3392 group objects shown. Download the .knxprod for the full list.

Parameters (381)
ParameterTypeDefault
Number of Indoor Units in ETSunsignedInt 1…641
Activation Codetext
Download latest database entry for this product and its User Manual from:texthttp://www.intesisbox.com
Enable object "Error Code [2byte]"listDisabled
Enable object "Error Text [14byte]" (2 ASCII-char Error Code)listEnabled
Enable use of Filter Alarm Status and Reset objectslistDisabled
First Status Update to KNXlistASAP
Status_Mode report (HEAT/COOL) when AUTOlistNo
Enable use of "Mode Cool/Heat" objects (for control and status)listDisabled
Enable use of "Operating Mode" objects (for control and status)listDisabled
Enable use of +/- object for ModelistDisabled
> Mode +/- operationlist0-Decrease / 1-Increase [DPT_1.007]
Enable use of bit-type Mode objects (for control)listDisabled
Enable use of bit-type Mode objects (for status)listDisabled
Enable use of Text object for ModelistDisabled
> String when mode is AUTOtextAUTO
> String when mode is HEATtextHEAT
> String when mode is COOLtextCOOL
> String when mode is FANtextFAN
> String when mode is DRYtextDRY
DPT object type for fan speedlistScaling [DPT_5.001]
Enable use of "Fan Speed Man/Auto" objects (for control and status)listDisabled
Enable use of +/- object for Fan SpeedlistDisabled
> Fan speed +/- operationlist0-Decrease / 1-Increase [DPT_1.007]
> Sequence for +/- objectlistS1 > S2 > ... > SN
Enable use of bit-type Fan Speed objects (for control)listDisabled
Enable use of bit-type Fan Speed objects (for status)listDisabled
Enable use of Text object for Fan SpeedlistDisabled
> String when fan speed is 1textSPEED 1
> String when fan speed is 2textSPEED 2
> String when fan speed is 3textSPEED 3
> String when fan speed is AUTOtextAUTO
DPT object type for vanes U-DlistScaling [DPT_5.001]
Enable use of "Vanes U-D Swing/Stop" objects (for control and status)listEnabled
Enable use of +/- object for vaneslistDisabled
> Vanes U-D +/- operationlist0-Decrease / 1-Increase [DPT_1.007]
Enable use of bit-type Vanes U-D objects (for control)listDisabled
Enable use of bit-type Vanes U-D objects (for status)listDisabled
Enable use of Text object for Vanes U-DlistDisabled
> String when vanes U-D are in POS1textU-D POS1
> String when vanes U-D are in POS2textU-D POS2
> String when vanes U-D are in POS3textU-D POS3
> String when vanes U-D are in POS4textU-D POS4
> String when vanes U-D are in POS5textU-D POS5
> String when vanes U-D are in SWINGtextU-D SWING
> String when vanes U-D are in STOPtextU-D STOP
Enable use of +/- object for SetpointlistDisabled
> Setpoint +/- operationlist0-Decrease / 1-Increase [DPT_1.007]
Ambient temp. ref. is provided from KNX (carefully read User Guide if enabled)listDisabled
Enable use of Control Mode objectslistDisabled
> Initial state of Control Mode in AC01list(Do not initialize)
IDU index (in Modbus GW) of AC01unsignedInt 0…630
Supported operating modeslistAll Indoor Units support same operating modes
> Supported operating modeslistAuto - Heat - Cool - Fan - Dry
Supported fan speedslistAll Indoor Units support same fan speeds
> Supported fan speedslistAuto - S1 - S2 - S3
> Supported modes in AC01listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC01listAuto - S1 - S2 - S3
Initial state of Control ModelistApply same initial state to all Indoor Units
> Initial state of Control Modelist(Do not initialize)
Intesis ProductlistHA-AC-KNX-8
>> WARNINGtextToo many Indoor Units for this product!
Modbus GW address of AC01unsignedInt 1…321
Periodic sending of "Status_ AC Setp" (in seconds;0=No periodic sending)unsignedInt 0…2550
Transmission of "Status_ AC Ambient Ref Temp"listOnly on change
> "Status_ AC Ambient Ref Temp" periodic sending time (in sec)unsignedInt 1…255180
> Initial state of Control Mode in AC02list(Do not initialize)
IDU index (in Modbus GW) of AC02unsignedInt 0…631
> Supported modes in AC02listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC02listAuto - S1 - S2 - S3
Modbus GW address of AC02unsignedInt 1…321
> Initial state of Control Mode in AC03list(Do not initialize)
IDU index (in Modbus GW) of AC03unsignedInt 0…632
> Supported modes in AC03listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC03listAuto - S1 - S2 - S3
Modbus GW address of AC03unsignedInt 1…321
> Initial state of Control Mode in AC04list(Do not initialize)
IDU index (in Modbus GW) of AC04unsignedInt 0…633
> Supported modes in AC04listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC04listAuto - S1 - S2 - S3
Modbus GW address of AC04unsignedInt 1…321
> Initial state of Control Mode in AC05list(Do not initialize)
IDU index (in Modbus GW) of AC05unsignedInt 0…634
> Supported modes in AC05listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC05listAuto - S1 - S2 - S3
Modbus GW address of AC05unsignedInt 1…321
> Initial state of Control Mode in AC06list(Do not initialize)
IDU index (in Modbus GW) of AC06unsignedInt 0…635
> Supported modes in AC06listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC06listAuto - S1 - S2 - S3
Modbus GW address of AC06unsignedInt 1…321
> Initial state of Control Mode in AC07list(Do not initialize)
IDU index (in Modbus GW) of AC07unsignedInt 0…636
> Supported modes in AC07listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC07listAuto - S1 - S2 - S3
Modbus GW address of AC07unsignedInt 1…321
> Initial state of Control Mode in AC08list(Do not initialize)
IDU index (in Modbus GW) of AC08unsignedInt 0…637
> Supported modes in AC08listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC08listAuto - S1 - S2 - S3
Modbus GW address of AC08unsignedInt 1…321
> Initial state of Control Mode in AC09list(Do not initialize)
IDU index (in Modbus GW) of AC09unsignedInt 0…638
> Supported modes in AC09listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC09listAuto - S1 - S2 - S3
Modbus GW address of AC09unsignedInt 1…321
> Initial state of Control Mode in AC10list(Do not initialize)
IDU index (in Modbus GW) of AC10unsignedInt 0…639
> Supported modes in AC10listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC10listAuto - S1 - S2 - S3
Modbus GW address of AC10unsignedInt 1…321
> Initial state of Control Mode in AC11list(Do not initialize)
IDU index (in Modbus GW) of AC11unsignedInt 0…6310
> Supported modes in AC11listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC11listAuto - S1 - S2 - S3
Modbus GW address of AC11unsignedInt 1…321
> Initial state of Control Mode in AC12list(Do not initialize)
IDU index (in Modbus GW) of AC12unsignedInt 0…6311
> Supported modes in AC12listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC12listAuto - S1 - S2 - S3
Modbus GW address of AC12unsignedInt 1…321
> Initial state of Control Mode in AC13list(Do not initialize)
IDU index (in Modbus GW) of AC13unsignedInt 0…6312
> Supported modes in AC13listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC13listAuto - S1 - S2 - S3
Modbus GW address of AC13unsignedInt 1…321
> Initial state of Control Mode in AC14list(Do not initialize)
IDU index (in Modbus GW) of AC14unsignedInt 0…6313
> Supported modes in AC14listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC14listAuto - S1 - S2 - S3
Modbus GW address of AC14unsignedInt 1…321
> Initial state of Control Mode in AC15list(Do not initialize)
IDU index (in Modbus GW) of AC15unsignedInt 0…6314
> Supported modes in AC15listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC15listAuto - S1 - S2 - S3
Modbus GW address of AC15unsignedInt 1…321
> Initial state of Control Mode in AC16list(Do not initialize)
IDU index (in Modbus GW) of AC16unsignedInt 0…6315
> Supported modes in AC16listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC16listAuto - S1 - S2 - S3
Modbus GW address of AC16unsignedInt 1…321
> Initial state of Control Mode in AC17list(Do not initialize)
IDU index (in Modbus GW) of AC17unsignedInt 0…6316
> Supported modes in AC17listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC17listAuto - S1 - S2 - S3
Modbus GW address of AC17unsignedInt 1…321
> Initial state of Control Mode in AC18list(Do not initialize)
IDU index (in Modbus GW) of AC18unsignedInt 0…6317
> Supported modes in AC18listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC18listAuto - S1 - S2 - S3
Modbus GW address of AC18unsignedInt 1…321
> Initial state of Control Mode in AC19list(Do not initialize)
IDU index (in Modbus GW) of AC19unsignedInt 0…6318
> Supported modes in AC19listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC19listAuto - S1 - S2 - S3
Modbus GW address of AC19unsignedInt 1…321
> Initial state of Control Mode in AC20list(Do not initialize)
IDU index (in Modbus GW) of AC20unsignedInt 0…6319
> Supported modes in AC20listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC20listAuto - S1 - S2 - S3
Modbus GW address of AC20unsignedInt 1…321
> Initial state of Control Mode in AC21list(Do not initialize)
IDU index (in Modbus GW) of AC21unsignedInt 0…6320
> Supported modes in AC21listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC21listAuto - S1 - S2 - S3
Modbus GW address of AC21unsignedInt 1…321
> Initial state of Control Mode in AC22list(Do not initialize)
IDU index (in Modbus GW) of AC22unsignedInt 0…6321
> Supported modes in AC22listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC22listAuto - S1 - S2 - S3
Modbus GW address of AC22unsignedInt 1…321
> Initial state of Control Mode in AC23list(Do not initialize)
IDU index (in Modbus GW) of AC23unsignedInt 0…6322
> Supported modes in AC23listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC23listAuto - S1 - S2 - S3
Modbus GW address of AC23unsignedInt 1…321
> Initial state of Control Mode in AC24list(Do not initialize)
IDU index (in Modbus GW) of AC24unsignedInt 0…6323
> Supported modes in AC24listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC24listAuto - S1 - S2 - S3
Modbus GW address of AC24unsignedInt 1…321
> Initial state of Control Mode in AC25list(Do not initialize)
IDU index (in Modbus GW) of AC25unsignedInt 0…6324
> Supported modes in AC25listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC25listAuto - S1 - S2 - S3
Modbus GW address of AC25unsignedInt 1…321
> Initial state of Control Mode in AC26list(Do not initialize)
IDU index (in Modbus GW) of AC26unsignedInt 0…6325
> Supported modes in AC26listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC26listAuto - S1 - S2 - S3
Modbus GW address of AC26unsignedInt 1…321
> Initial state of Control Mode in AC27list(Do not initialize)
IDU index (in Modbus GW) of AC27unsignedInt 0…6326
> Supported modes in AC27listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC27listAuto - S1 - S2 - S3
Modbus GW address of AC27unsignedInt 1…321
> Initial state of Control Mode in AC28list(Do not initialize)
IDU index (in Modbus GW) of AC28unsignedInt 0…6327
> Supported modes in AC28listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC28listAuto - S1 - S2 - S3
Modbus GW address of AC28unsignedInt 1…321
> Initial state of Control Mode in AC29list(Do not initialize)
IDU index (in Modbus GW) of AC29unsignedInt 0…6328
> Supported modes in AC29listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC29listAuto - S1 - S2 - S3
Modbus GW address of AC29unsignedInt 1…321
> Initial state of Control Mode in AC30list(Do not initialize)
IDU index (in Modbus GW) of AC30unsignedInt 0…6329
> Supported modes in AC30listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC30listAuto - S1 - S2 - S3
Modbus GW address of AC30unsignedInt 1…321
> Initial state of Control Mode in AC31list(Do not initialize)
IDU index (in Modbus GW) of AC31unsignedInt 0…6330
> Supported modes in AC31listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC31listAuto - S1 - S2 - S3
Modbus GW address of AC31unsignedInt 1…321
> Initial state of Control Mode in AC32list(Do not initialize)
IDU index (in Modbus GW) of AC32unsignedInt 0…6331
> Supported modes in AC32listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC32listAuto - S1 - S2 - S3
Modbus GW address of AC32unsignedInt 1…321
> Initial state of Control Mode in AC33list(Do not initialize)
IDU index (in Modbus GW) of AC33unsignedInt 0…6332
> Supported modes in AC33listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC33listAuto - S1 - S2 - S3
Modbus GW address of AC33unsignedInt 1…321
> Initial state of Control Mode in AC34list(Do not initialize)
IDU index (in Modbus GW) of AC34unsignedInt 0…6333
> Supported modes in AC34listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC34listAuto - S1 - S2 - S3
Modbus GW address of AC34unsignedInt 1…321
> Initial state of Control Mode in AC35list(Do not initialize)
IDU index (in Modbus GW) of AC35unsignedInt 0…6334
> Supported modes in AC35listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC35listAuto - S1 - S2 - S3
Modbus GW address of AC35unsignedInt 1…321
> Initial state of Control Mode in AC36list(Do not initialize)
IDU index (in Modbus GW) of AC36unsignedInt 0…6335
> Supported modes in AC36listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC36listAuto - S1 - S2 - S3
Modbus GW address of AC36unsignedInt 1…321
> Initial state of Control Mode in AC37list(Do not initialize)
IDU index (in Modbus GW) of AC37unsignedInt 0…6336
> Supported modes in AC37listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC37listAuto - S1 - S2 - S3
Modbus GW address of AC37unsignedInt 1…321
> Initial state of Control Mode in AC38list(Do not initialize)
IDU index (in Modbus GW) of AC38unsignedInt 0…6337
> Supported modes in AC38listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC38listAuto - S1 - S2 - S3
Modbus GW address of AC38unsignedInt 1…321
> Initial state of Control Mode in AC39list(Do not initialize)
IDU index (in Modbus GW) of AC39unsignedInt 0…6338
> Supported modes in AC39listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC39listAuto - S1 - S2 - S3
Modbus GW address of AC39unsignedInt 1…321
> Initial state of Control Mode in AC40list(Do not initialize)
IDU index (in Modbus GW) of AC40unsignedInt 0…6339
> Supported modes in AC40listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC40listAuto - S1 - S2 - S3
Modbus GW address of AC40unsignedInt 1…321
> Initial state of Control Mode in AC41list(Do not initialize)
IDU index (in Modbus GW) of AC41unsignedInt 0…6340
> Supported modes in AC41listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC41listAuto - S1 - S2 - S3
Modbus GW address of AC41unsignedInt 1…321
> Initial state of Control Mode in AC42list(Do not initialize)
IDU index (in Modbus GW) of AC42unsignedInt 0…6341
> Supported modes in AC42listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC42listAuto - S1 - S2 - S3
Modbus GW address of AC42unsignedInt 1…321
> Initial state of Control Mode in AC43list(Do not initialize)
IDU index (in Modbus GW) of AC43unsignedInt 0…6342
> Supported modes in AC43listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC43listAuto - S1 - S2 - S3
Modbus GW address of AC43unsignedInt 1…321
> Initial state of Control Mode in AC44list(Do not initialize)
IDU index (in Modbus GW) of AC44unsignedInt 0…6343
> Supported modes in AC44listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC44listAuto - S1 - S2 - S3
Modbus GW address of AC44unsignedInt 1…321
> Initial state of Control Mode in AC45list(Do not initialize)
IDU index (in Modbus GW) of AC45unsignedInt 0…6344
> Supported modes in AC45listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC45listAuto - S1 - S2 - S3
Modbus GW address of AC45unsignedInt 1…321
> Initial state of Control Mode in AC46list(Do not initialize)
IDU index (in Modbus GW) of AC46unsignedInt 0…6345
> Supported modes in AC46listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC46listAuto - S1 - S2 - S3
Modbus GW address of AC46unsignedInt 1…321
> Initial state of Control Mode in AC47list(Do not initialize)
IDU index (in Modbus GW) of AC47unsignedInt 0…6346
> Supported modes in AC47listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC47listAuto - S1 - S2 - S3
Modbus GW address of AC47unsignedInt 1…321
> Initial state of Control Mode in AC48list(Do not initialize)
IDU index (in Modbus GW) of AC48unsignedInt 0…6347
> Supported modes in AC48listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC48listAuto - S1 - S2 - S3
Modbus GW address of AC48unsignedInt 1…321
> Initial state of Control Mode in AC49list(Do not initialize)
IDU index (in Modbus GW) of AC49unsignedInt 0…6348
> Supported modes in AC49listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC49listAuto - S1 - S2 - S3
Modbus GW address of AC49unsignedInt 1…321
> Initial state of Control Mode in AC50list(Do not initialize)
IDU index (in Modbus GW) of AC50unsignedInt 0…6349
> Supported modes in AC50listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC50listAuto - S1 - S2 - S3
Modbus GW address of AC50unsignedInt 1…321
> Initial state of Control Mode in AC51list(Do not initialize)
IDU index (in Modbus GW) of AC51unsignedInt 0…6350
> Supported modes in AC51listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC51listAuto - S1 - S2 - S3
Modbus GW address of AC51unsignedInt 1…321
> Initial state of Control Mode in AC52list(Do not initialize)
IDU index (in Modbus GW) of AC52unsignedInt 0…6351
> Supported modes in AC52listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC52listAuto - S1 - S2 - S3
Modbus GW address of AC52unsignedInt 1…321
> Initial state of Control Mode in AC53list(Do not initialize)
IDU index (in Modbus GW) of AC53unsignedInt 0…6352
> Supported modes in AC53listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC53listAuto - S1 - S2 - S3
Modbus GW address of AC53unsignedInt 1…321
> Initial state of Control Mode in AC54list(Do not initialize)
IDU index (in Modbus GW) of AC54unsignedInt 0…6353
> Supported modes in AC54listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC54listAuto - S1 - S2 - S3
Modbus GW address of AC54unsignedInt 1…321
> Initial state of Control Mode in AC55list(Do not initialize)
IDU index (in Modbus GW) of AC55unsignedInt 0…6354
> Supported modes in AC55listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC55listAuto - S1 - S2 - S3
Modbus GW address of AC55unsignedInt 1…321
> Initial state of Control Mode in AC56list(Do not initialize)
IDU index (in Modbus GW) of AC56unsignedInt 0…6355
> Supported modes in AC56listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC56listAuto - S1 - S2 - S3
Modbus GW address of AC56unsignedInt 1…321
> Initial state of Control Mode in AC57list(Do not initialize)
IDU index (in Modbus GW) of AC57unsignedInt 0…6356
> Supported modes in AC57listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC57listAuto - S1 - S2 - S3
Modbus GW address of AC57unsignedInt 1…321
> Initial state of Control Mode in AC58list(Do not initialize)
IDU index (in Modbus GW) of AC58unsignedInt 0…6357
> Supported modes in AC58listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC58listAuto - S1 - S2 - S3
Modbus GW address of AC58unsignedInt 1…321
> Initial state of Control Mode in AC59list(Do not initialize)
IDU index (in Modbus GW) of AC59unsignedInt 0…6358
> Supported modes in AC59listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC59listAuto - S1 - S2 - S3
Modbus GW address of AC59unsignedInt 1…321
> Initial state of Control Mode in AC60list(Do not initialize)
IDU index (in Modbus GW) of AC60unsignedInt 0…6359
> Supported modes in AC60listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC60listAuto - S1 - S2 - S3
Modbus GW address of AC60unsignedInt 1…321
> Initial state of Control Mode in AC61list(Do not initialize)
IDU index (in Modbus GW) of AC61unsignedInt 0…6360
> Supported modes in AC61listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC61listAuto - S1 - S2 - S3
Modbus GW address of AC61unsignedInt 1…321
> Initial state of Control Mode in AC62list(Do not initialize)
IDU index (in Modbus GW) of AC62unsignedInt 0…6361
> Supported modes in AC62listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC62listAuto - S1 - S2 - S3
Modbus GW address of AC62unsignedInt 1…321
> Initial state of Control Mode in AC63list(Do not initialize)
IDU index (in Modbus GW) of AC63unsignedInt 0…6362
> Supported modes in AC63listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC63listAuto - S1 - S2 - S3
Modbus GW address of AC63unsignedInt 1…321
> Initial state of Control Mode in AC64list(Do not initialize)
IDU index (in Modbus GW) of AC64unsignedInt 0…6363
> Supported modes in AC64listAuto - Heat - Cool - Fan - Dry
> Supported fan speeds in AC64listAuto - S1 - S2 - S3
Modbus GW address of AC64unsignedInt 1…321

Application program: HAACKNX T2AV10 (e) 1.0

Application number$002A
Version1.0
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version4.0
Parameters0
Group objects0
Group objects (0)
NoNameFunctionSizeDPTFlags
Parameters (0)
ParameterTypeDefault

Version history

ApplicationApp noFingerprintFirst seenSizeFile
HAACKNX T29V10 (p) 1.0 latest$102A578C2026-11-25354 KBDownload

About this file

This is the official ETS product database for the Intesis HA AC interface (multiple indoor units) (HA-AC-KNX), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.