Intesis LG-RC-KNX-1i LG RC interface, 4 binary inputs

LG RC interface, 4 binary inputs LG-RC-KNX-1i

Intesis · Order number LG-RC-KNX-1i · Communication › Interfaces › LG Air Conditioning Interfaces

Download .knxprod 0110 LGRCKNX1i T10V14 1.4 · 147 KB

Product

ManufacturerIntesis
Product nameLG RC interface, 4 binary inputs
Order numberLG-RC-KNX-1i
HardwareLG RC Interface
MediumTwisted Pair
Bus current (mA)8
Rail mountedNo
RegistrationCertified · 2014-05-12
Languageses-ES, en-US
Catalog entryM-0077_H-LG.2DRC.2DKNX.2D1i-16_HP-0010-14-1164_CI-LG.2DRC.2DKNX.2D1i-1
Fingerprint1164
SHA-2569ce77741cf188f937bda305e75bf2c774ddb8177cf03c4f253248393d88d8739
First seen2026-11-25
Markets69 markets

Application program: 0110 LGRCKNX1i T10V14 1.4

Application number$0010
Version1.4
Mask versionMV-0025 (2.5)
KNX Data SecureNo
Parameters371
Group objects139
Group objects (139)
NoNameFunctionSizeDPTFlags
0Control_ On/Off [DPT_1.001 - 1bit]0-Off;1-On1 Bit1.1 switchCWT
1Control_ Mode [DPT_20.105 - 1byte]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 ByteCWT
2Control_ Mode Cool/Heat [DPT_1.100 - 1bit]0-Cool;1-Heat1 BitCWT
3Control_ Mode Cool & On [DPT_5.001 - 1byte]0%-Off;0.1%-100%-On+Cool1 Byte5.1 percentage (0..100%)CWT
4Control_ Mode Heat & On [DPT_5.001 - 1byte]0%-Off;0.1%-100%-On+Heat1 Byte5.1 percentage (0..100%)CWT
5Control_ Mode Auto [DPT_1.002 - 1bit]1-Set AUTO mode1 Bit1.2 booleanCWT
6Control_ Mode Heat [DPT_1.002 - 1bit]1-Set HEAT mode1 Bit1.2 booleanCWT
7Control_ Mode Cool [DPT_1.002 - 1bit]1-Set COOL mode1 Bit1.2 booleanCWT
8Control_ Mode Fan [DPT_1.002 - 1bit]1-Set FAN mode1 Bit1.2 booleanCWT
9Control_ Mode Dry [DPT_1.002 - 1bit]1-Set DRY mode1 Bit1.2 booleanCWT
10Control_ Mode -/+ [DPT_1.007 - 1bit]0-Decrease;1-Increase1 BitCW
10Control_ Mode +/- [DPT_1.008 - 1bit]0-Up;1-Down1 Bit1.8 up/downCW
11Control_ Fan Speed / 4 Speeds [DPT_5.001 - 1byte]Thresholds: 38, 63 and 88%1 Byte5.1 percentage (0..100%)CWT
11Control_ Fan Speed / 4 Speeds [DPT_5.010 - 1byte] Speed values: 1,2,3,41 Byte5.10 counter pulses (0..255)CWT
11Control_ Fan Speed / 3 Speeds [DPT_5.001 - 1byte]Thresholds: 50 and 83%1 Byte5.1 percentage (0..100%)CWT
11Control_ Fan Speed / 3 Speeds [DPT_5.010 - 1byte] Speed values: 1,2,31 Byte5.10 counter pulses (0..255)CWT
12Control_ Fan Speed Man/Auto [DPT_1.002 - 1bit]0-Manual; 1-Auto1 Bit1.2 booleanCWT
13Control_ Fan Speed 1 [DPT_1.002 - 1bit]1-Set Fan Speed 11 Bit1.2 booleanCWT
14Control_ Fan Speed 2 [DPT_1.002 - 1bit]1-Set Fan Speed 21 Bit1.2 booleanCWT
15Control_ Fan Speed 3 [DPT_1.002 - 1bit]1-Set Fan Speed 31 Bit1.2 booleanCWT
16Control_ Fan Speed 4 [DPT_1.002 - 1bit]1-Set Fan Speed 41 Bit1.2 booleanCWT
17Control_ Fan Speed -/+ [DPT_1.007 - 1bit]0-Decrease;1-Increase1 BitCW
17Control_ Fan Speed +/- [DPT_1.008 - 1bit]0-Up;1-Down1 Bit1.8 up/downCW
18Control_ Vanes U-D Swing [DPT_1.002 - 1bit]0-Off;1-Swing1 Bit1.2 booleanCWT
19Control_ Vanes U-D Swirl [DPT_1.002 - 1bit]0-Off;1-Swirl1 Bit1.2 booleanCWT
20Control_ Vanes L-R Swing [DPT_1.002 - 1bit]0-Off;1-Swing1 Bit1.2 booleanCWT
21Control_ Vanes L-R Swirl [DPT_1.002 - 1bit]0-Off;1-Swirl1 Bit1.2 booleanCWT
22Control_ Setpoint Temp [DPT_9.001 - 2byte]ºC2 Bytes9.1 temperature (°C)CWT
23Control_ Setpoint Temp -/+ [DPT_1.007 - 1bit]0-Decrease;1-Increase1 BitCW
23Control_ Setpoint Temp +/- [DPT_1.008 - 1bit]0-Up;1-Down1 Bit1.8 up/downCW
24Control_ Ambient Temp [DPT_9.001 - 2byte]ºC2 Bytes9.1 temperature (°C)CWT
25Control_ Switch Off Timeout [DPT_1.010 - 1bit]0-Stop;1-Start1 Bit1.10 start/stopCWT
25Control_ Window Contact Status [DPT_1.009 - 1bit]0-Open;1-Closed1 Bit1.9 open/closeCWT
26Control_ Occupancy [DPT_1.018 - 1bit]0-Not Occupied;1-Occupied1 BitCWT
27Control_ Sleep Timeout [DPT_1.010 - 1bit]0-Stop;1-Start1 Bit1.10 start/stopCWT
28Control_ Lock Remote Control [DPT_1.002 - 1bit]0-Unlock;1-Lock1 Bit1.2 booleanCWT
29Control_ Lock Control Objects [DPT_1.002 - 1bit]0-Unlock;1-Lock1 Bit1.2 booleanCWT
30Control_ Power Mode [DPT_1.010 - 1bit]0-Stop;1-Start1 Bit1.10 start/stopCWT
31Control_ Econo Mode [DPT_1.010 - 1bit]0-Stop;1-Start1 Bit1.10 start/stopCWT
32Control_ Additional Heat [DPT_1.010 - 1bit]0-Stop;1-Start1 Bit1.10 start/stopCWT
33Control_ Additional Cool [DPT_1.010 - 1bit]0-Stop;1-Start1 Bit1.10 start/stopCWT
34Control_ Execute Scene [DPT_17.001 - 1byte]0..4-Exec1-51 ByteCWT
34Control_ Save/Exec Scene [DPT_18.001 - 1byte]0..4-Exec1-5;128..132-Save1-51 ByteCWT
35Control_ Store Scene 1 [DPT_1.002 - 1bit]1-Store Scene 11 Bit1.2 booleanCW
36Control_ Store Scene 2 [DPT_1.002 - 1bit]1-Store Scene 21 Bit1.2 booleanCW
37Control_ Store Scene 3 [DPT_1.002 - 1bit]1-Store Scene 31 Bit1.2 booleanCW
38Control_ Store Scene 4 [DPT_1.002 - 1bit]1-Store Scene 41 Bit1.2 booleanCW
39Control_ Store Scene 5 [DPT_1.002 - 1bit]1-Store Scene 51 Bit1.2 booleanCW
40Control_ Execute Scene 1 [DPT_1.002 - 1bit]1-Execute Scene 11 Bit1.2 booleanCWT
41Control_ Execute Scene 2 [DPT_1.002 - 1bit]1-Execute Scene 21 Bit1.2 booleanCWT
42Control_ Execute Scene 3 [DPT_1.002 - 1bit]1-Execute Scene 31 Bit1.2 booleanCWT
43Control_ Execute Scene 4 [DPT_1.002 - 1bit]1-Execute Scene 41 Bit1.2 booleanCWT
44Control_ Execute Scene 5 [DPT_1.002 - 1bit]1-Execute Scene 51 Bit1.2 booleanCWT
45Control_ Disable Input 1 [DPT_1.003 - 1bit]0-Disable;1-Enable1 Bit1.3 enableCWT
45Control_ Disable Input 1 [DPT_1.002 - 1bit]0-False;1-True1 Bit1.2 booleanCWT
46Control_ Disable Input 2 [DPT_1.003 - 1bit]0-Disable;1-Enable1 Bit1.3 enableCWT
46Control_ Disable Input 2 [DPT_1.002 - 1bit]0-False;1-True1 Bit1.2 booleanCWT
47Control_ Disable Input 3 [DPT_1.002 - 1bit]0-False;1-True1 Bit1.2 booleanCWT
47Control_ Disable Input 3 [DPT_1.003 - 1bit]0-Disable;1-Enable1 Bit1.3 enableCWT
48Control_ Disable Input 4 [DPT_1.002 - 1bit]0-False;1-True1 Bit1.2 booleanCWT
48Control_ Disable Input 4 [DPT_1.003 - 1bit]0-Disable;1-Enable1 Bit1.3 enableCWT
49Control_ Back to Factory Settings [DPT_1.015]1-Reset1 BitCWT
50Status_ On/Off [DPT_1.001 - 1bit]0-Off;1-On1 Bit1.1 switchCRT
51Status_ Mode [DPT_20.105 - 1byte]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 ByteCRT
52Status_ Mode Cool/Heat [DPT_1.100 - 1bit]0-Cool;1-Heat1 BitCRT
53Status_ Mode Auto [DPT_1.002 - 1bit]1-AUTO mode is active1 Bit1.2 booleanCRT
54Status_ Mode Heat [DPT_1.002 - 1bit]1-HEAT mode is active1 Bit1.2 booleanCRT
55Status_ Mode Cool [DPT_1.002 - 1bit]1-COOL mode is active1 Bit1.2 booleanCRT
56Status_ Mode Fan [DPT_1.002 - 1bit]1-FAN mode is active1 Bit1.2 booleanCRT
57Status_ Mode Dry [DPT_1.002 - 1bit]1-DRY mode is active1 Bit1.2 booleanCRT
58Status_ Mode Text [DPT_16.001 - 14byte]ASCII String14 Bytes16.1 Character String (ISO 8859-1)CRT
59Status_ Fan Speed / 4 Speeds [DPT_5.001 - 1byte]25, 50, 75 and 100%1 Byte5.1 percentage (0..100%)CRT
59Status_ Fan Speed / 4 Speeds [DPT_5.010 - 1byte]Speed Values: 1,2,3,41 Byte5.10 counter pulses (0..255)CRT
59Status_ Fan Speed / 3 Speeds [DPT_5.001 - 1byte]33, 66 and 100%1 Byte5.1 percentage (0..100%)CRT
59Status_ Fan Speed / 3 Speeds [DPT_5.010 - 1byte]Speed Values: 1,2,31 Byte5.10 counter pulses (0..255)CRT
60Status_ Fan Speed Man/Auto [DPT_1.002 - 1bit]0-Manual;1-Auto1 Bit1.2 booleanCRT
61Status_ Fan Speed 1 [DPT_1.002 - 1bit]1-Fan in speed 11 Bit1.2 booleanCRT
62Status_ Fan Speed 2 [DPT_1.002 - 1bit]1-Fan in speed 21 Bit1.2 booleanCRT
63Status_ Fan Speed 3 [DPT_1.002 - 1bit]1-Fan in speed 31 Bit1.2 booleanCRT
64Status_ Fan Speed 4 [DPT_1.002 - 1bit]1-Fan in speed 41 Bit1.2 booleanCRT
65Status_ Fan Speed Text [DPT_16.001 - 14byte]ASCII String14 Bytes16.1 Character String (ISO 8859-1)CRT
66Status_ Vanes U-D Swing [DPT_1.002 - 1bit]0-Off;1-Swing1 Bit1.2 booleanCRT
67Status_ Vanes U-D Swirl [DPT_1.002 - 1bit]0-Off;1-Swirl1 Bit1.2 booleanCRT
68Status_ Vanes L-R Swing [DPT_1.002 - 1bit]0-Off;1-Swing1 Bit1.2 booleanCRT
69Status_ Vanes L-R Swirl [DPT_1.002 - 1bit]0-Off;1-Swirl1 Bit1.2 booleanCRT
70Status_ AC Setpoint Temp [DPT_9.001 - 2byte]ºC2 Bytes9.1 temperature (°C)CRT
71Status_ AC Ambient Ref Temp [DPT_9.001 - 2byte]ºC2 Bytes9.1 temperature (°C)CRT
72Status_ Error/Alarm [DPT_1.005 - 1bit]0-No alarm;1-Alarm1 BitCRT
73Status_ Error Code [2byte]0-No error /Any other see man.2 BytesCRT
74Status_ Error Text Code [DPT_16.001 - 14byte]2-char LG Error; Empty-None14 Bytes16.1 Character String (ISO 8859-1)CRT
75Status_ Lock Remote Control [DPT_1.002 - 1bit]0-Unlocked;1-Locked1 Bit1.2 booleanCRT
76Status_ Lock Control Objects [DPT_1.002 - 1bit]0-Unlocked;1-Locked1 Bit1.2 booleanCRT
77Status_ Power Mode [DPT_1.001 - 1bit]0-Off;1-On1 Bit1.1 switchCRT
78Status_ Econo Mode [DPT_1.001 - 1bit]0-Off;1-On1 Bit1.1 switchCRT
79Status_ Additional Heat [DPT_1.001 - 1bit]0-Off;1-On1 Bit1.1 switchCRT
80Status_ Additional Cool [DPT_1.001 - 1bit]0-Off;1-On1 Bit1.1 switchCRT
81Status_ Operating Hour Counter [DPT_7.007 - 2byte]Number of operating hours2 BytesCRT
82Status_ Operating Sec Counter [DPT_13.100 - 4byte]Number of operating seconds4 BytesCRT
83Status_ Current Scene [DPT_17.001 - 1byte]0..4-Scene X+1;63-No Scene1 ByteCRT
84Status_ In1 - Switching [DPT_1.001 - 1bit]0-Off;1-On1 Bit1.1 switchCRT
84Status_ In1 - Dimming - On/Off [DPT_1.001 - 1bit]0-Off;1-On1 Bit1.1 switchCRT
84Status_ In1 - Shut/Blind - Step [DPT_1.007 - 1bit]0-Step Up;1-Step Down1 BitCRT
85Status_ In1 - Dimming - Step(%) [DPT_3.007 - 4bit]Dimming step4 Bit3.7 dimming controlCRT
85Status_ In1 - Shut/Blind - Move [DPT_1.008 - 1bit]0-Move Up;1-Move Down1 Bit1.8 up/downCRT
85Status_ In1 - Value [DPT_12.001 - 12byte]4-byte unsigned value4 Bytes12.1 counter pulses (unsigned)CRT
85Status_ In1 - Value [DPT_5.010 - 1byte]1-byte unsigned value1 Byte5.10 counter pulses (0..255)CRT
85Status_ In1 - Value [DPT_8.001 - 2byte]2-byte signed value2 Bytes8.1 pulses differenceCRT
85Status_ In1 - Value [DPT_9.001 - 2byte]Temperature (ºC)2 Bytes9.1 temperature (°C)CRT
85Status_ In1 - Value [DPT_7.001 - 2byte]2-byte unsigned value2 Bytes7.1 pulsesCRT
86Status_ In2 - Switching [DPT_1.001 - 1bit]0-Off;1-On1 Bit1.1 switchCRT
86Status_ In2 - Dimming - On/Off [DPT_1.001 - 1bit]0-Off;1-On1 Bit1.1 switchCRT
86Status_ In2 - Shut/Blind - Step [DPT_1.007 - 1bit]0-Step Up;1-Step Down1 BitCRT
87Status_ In2 - Dimming - Step(%) [DPT_3.007 - 4bit]Dimming step4 Bit3.7 dimming controlCRT
87Status_ In2 - Value [DPT_7.001 - 2byte]2-byte unsigned value2 Bytes7.1 pulsesCRT
87Status_ In2 - Value [DPT_12.001 - 12byte]4-byte unsigned value4 Bytes12.1 counter pulses (unsigned)CRT
87Status_ In2 - Value [DPT_9.001 - 2byte]Temperature (ºC)2 Bytes9.1 temperature (°C)CRT
87Status_ In2 - Value [DPT_8.001 - 2byte]2-byte signed value2 Bytes8.1 pulses differenceCRT
87Status_ In2 - Value [DPT_5.010 - 1byte]1-byte unsigned value1 Byte5.10 counter pulses (0..255)CRT
87Status_ In2 - Shut/Blind - Move [DPT_1.008 - 1bit]0-Move Up;1-Move Down1 Bit1.8 up/downCRT
88Status_ In3 - Switching [DPT_1.001 - 1bit]0-Off;1-On1 Bit1.1 switchCRT
88Status_ In3 - Dimming - On/Off [DPT_1.001 - 1bit]0-Off;1-On1 Bit1.1 switchCRT
88Status_ In3 - Shut/Blind - Step [DPT_1.007 - 1bit]0-Step Up;1-Step Down1 BitCRT
89Status_ In3 - Dimming - Step(%) [DPT_3.007 - 4bit]Dimming step4 Bit3.7 dimming controlCRT
89Status_ In3 - Value [DPT_12.001 - 12byte]4-byte unsigned value4 Bytes12.1 counter pulses (unsigned)CRT
89Status_ In3 - Value [DPT_9.001 - 2byte]Temperature (ºC)2 Bytes9.1 temperature (°C)CRT
89Status_ In3 - Value [DPT_8.001 - 2byte]2-byte signed value2 Bytes8.1 pulses differenceCRT
89Status_ In3 - Value [DPT_7.001 - 2byte]2-byte unsigned value2 Bytes7.1 pulsesCRT
89Status_ In3 - Value [DPT_5.010 - 1byte]1-byte unsigned value1 Byte5.10 counter pulses (0..255)CRT
89Status_ In3 - Shut/Blind - Move [DPT_1.008 - 1bit]0-Move Up;1-Move Down1 Bit1.8 up/downCRT
90Status_ In4 - Switching [DPT_1.001 - 1bit]0-Off;1-On1 Bit1.1 switchCRT
90Status_ In4 - Dimming - On/Off [DPT_1.001 - 1bit]0-Off;1-On1 Bit1.1 switchCRT
90Status_ In4 - Shut/Blind - Step [DPT_1.007 - 1bit]0-Step Up;1-Step Down1 BitCRT
91Status_ In4 - Dimming - Step(%) [DPT_3.007 - 4bit]Dimming step4 Bit3.7 dimming controlCRT
91Status_ In4 - Value [DPT_12.001 - 12byte]4-byte unsigned value4 Bytes12.1 counter pulses (unsigned)CRT
91Status_ In4 - Value [DPT_9.001 - 2byte]Temperature (ºC)2 Bytes9.1 temperature (°C)CRT
91Status_ In4 - Value [DPT_8.001 - 2byte]2-byte signed value2 Bytes8.1 pulses differenceCRT
91Status_ In4 - Value [DPT_7.001 - 2byte]2-byte unsigned value2 Bytes7.1 pulsesCRT
91Status_ In4 - Value [DPT_5.010 - 1byte]1-byte unsigned value1 Byte5.10 counter pulses (0..255)CRT
91Status_ In4 - Shut/Blind - Move [DPT_1.008 - 1bit]0-Move Up;1-Move Down1 Bit1.8 up/downCRT
Parameters (247)
ParameterTypeDefault
Download latest database entry for this product and its User Manual from:texthttp://www.intesis.com
LG protocol typelistType B
LG-RC-KNX-1i is master in bus (3-wire)listNo
Apply "Min Ambient Temp"listNo
Use characterization from LG buslistUse
Send READs for Control_ objects on bus recovery (T & U flags must be active)listNo
> Delay before sending READs (sec)unsignedInt 0…3010
Scene to load on bus recovery / startup (needs to define vals for that scene)list(none)
Disallow control from remote controllerlistNo
> Enable "Lock Remote" objectslistNo
Enable func "Lock Control Objects"listNo
Enable func "Operating Time Counter"listNo
> Enable object "Oper. Hour Counter"listNo
Enable use of objects for Filter (for Control and Status)listNo
Enable object "Error Code [2byte]"listNo
Enable object "Error Text Code [14byte]" (4 ASCII-char Error Code)listYes
Show special objectslistNo
Indoor unit has HEAT mode (see docum. for your indoor unit)listYes
Indoor unit has AUTO mode (see docum. for your indoor unit)listNo
Indoor unit has FAN mode (see docum. for your indoor unit)listYes
Indoor unit has DRY mode (see docum. for your indoor unit)listYes
When mode is AUTO Status_ objs report actual operating status (HEAT/COOL/..)listNo
Enable "Mode Cool/Heat" objects (for Control and Status)listNo
Enable PID-Compat. Scaling Mode objects (for Control)listNo
Enable use of +/- object for ModelistNo
> DPT type for +/- Mode Objectlist0-Decrease / 1-Increase [DPT_1.007]
Enable use of bit-type Mode objects (for Control)listNo
Enable use of bit-type Mode objects (for Status)listNo
Enable use of Text object for ModelistNo
ASCII strings shown in comm object "Status_ Mode Text"text<< 14-byte string values >>
> String when mode is AUTO (if available)textAUTO
> String when mode is HEAT (if available)textHEAT
> String when mode is COOLtextCOOL
> String when mode is FANtextFAN
> String when mode is DRYtextDRY
Enable use of Legacy_ object for Mode (compatible with old vers of XXACKNX1)listNo
Enable use of "POWERFUL" mode (AC feature)listNo
Enable use of "QUIET" mode (AC feature)listNo
Enable use of "ECONOMY" mode (AC feature)listNo
Enable use of POWER modelistNo
> Action time for this mode (minutes)unsignedInt 1…18030
> Setpoint delta increase (HEAT) or decrease (COOL) (ºC)list2.0 ºC
> Fan Speed for this modelistFAN SPEED 3
Enable use of ECONOMY modelistNo
> Setpoint delta decrease (HEAT) or increase (COOL) (ºC)list2.0 ºC
> Fan Speed for this modelistFAN SPEED 1
Enable use of ADDITIONAL HEATING modelistNo
> Setpoint temp for this mode (ºC)list30 ºC
> Fan Speed for this modelistFAN SPEED AUTO (if available)
Enable use of ADDITIONAL COOLING modelistNo
> Setpoint temp for this mode (ºC)list20 ºC
Fan is accessible in Indoor unit (see docum. for your indoor unit)listYes
Available fanspeeds in Indoor Unit (see docum. for your indoor unit)unsignedInt 3…54
Available fanspeeds in Indoor Unit (see docum. for your indoor unit)list4
Indoor unit has AUTO fan speed (see docum. for your indoor unit)listYes
When fan is AUTO Status_ objs report actual operating status (speed1/2/...)listNo
DPT object type for fanspeedlistScaling [DPT_5.001]
Enable use of +/- object for Fan SpeedlistNo
> DPT type for +/- Fan Speed objectlist0-Decrease / 1-Increase [DPT_1.007]
> Does +/- sequence include fan speed AUTO?listNo
> Rollover Speed at upper/lower limit (when controlling with +/- obj)listYes
Enable "Fan Speed Man/Auto" objects (for Control and Status)listNo
Enable use of bit-type Fan Speed objects (for Control)listNo
Enable use of bit-type Fan Speed objects (for Status)listNo
Enable use of Text object for Fan SpeedlistNo
ASCII strings shown in comm object "Status_ Fan Speed Text"text<< 14-byte string values >>
> String when fan speed is AUTO (if available)textAUTO
> String when fan speed is 1textSPEED 1
> String when fan speed is 2textSPEED 2
> String when fan speed is 3textSPEED 3
> String when fan speed is 4 (if available)textSPEED 4
> String when fan speed is 5 (if available)textSPEED 5
Enable use of Legacy_ object for Fan (compatible with old vers of XXACKNX1)listNo
Indoor unit has U-D Vanes (see docum. for your indoor unit)listNo
Type of Vanes ControllistSwing and Swirl
Available U-D positions in Indoor Unit (see docum. for your indoor unit)unsignedInt 0…44
Available U-D positions in Indoor Unit (see docum. for your indoor unit)list0 (only Swing)
Indoor unit has AUTO Vanes U-D (see docum. for your indoor unit)listNo
Indoor unit has SWING Vanes U-D (see docum. for your indoor unit)listYes
Indoor unit has Vanes Swirl (see docum. for your indoor unit)listYes
DPT object type for Vanes Up-DownlistScaling [DPT_5.001]
Enable use of +/- object for Vanes U-DlistNo
> DPT type for +/- Vanes U-D objectlist0-Decrease / 1-Increase [DPT_1.007]
> Does +/- sequence include STANDBY vanes Up-Down?listNo
> Does +/- sequence include SWING vanes Up-Down?listYes
> Rollover Vanes at upper/lower limit (when controlling with +/- obj)listYes
Enable "Vanes U-D Auto" objects (for Control and Status)listNo
Enable use of bit-type Vanes U-D objects (for Control)listNo
Enable use of bit-type Vanes U-D objects (for Status)listNo
Enable "Vanes U-D Swing" objects (for Control and Status)listYes
Enable use of Text object for Vanes U-DlistNo
ASCII strings shown in comm object "Status_ Vanes U-D Text"text<< 14-byte string values >>
> String when vanes U-D in STANDBYtextU-D AUTO
> String when vanes U-D in POS 1textU-D POS 1
> String when vanes U-D in POS 2textU-D POS 2
> String when vanes U-D in POS 3textU-D POS 3
> String when vanes U-D in POS 4textU-D POS 4
> String when vanes U-D in POS 5textU-D POS 5
> String when vanes U-D in SWINGtextU-D SWING
Enable use of Legacy_ object for Vanes (compatible with old vers of XXACKNX1)listNo
Indoor unit has L-R Vanes (see docum. for your indoor unit)listNo
Available L-R positions in Indoor Unit (see docum. for your indoor unit)unsignedInt 0…55
Available L-R positions in Indoor Unit (see docum. for your indoor unit)list0 (only Swing)
Indoor unit has AUTO Vanes L-R (see docum. for your indoor unit)listNo
Indoor unit has SWING Vanes L-R (see docum. for your indoor unit)listYes
DPT object type for Vanes Left-RightlistScaling [DPT_5.001]
Enable use of +/- object for Vanes L-RlistNo
> DPT type for +/- Vanes L-R objectlist0-Decrease / 1-Increase [DPT_1.007]
> Does +/- sequence include AUTO vanes Left-Right?listNo
> Does +/- sequence include SWING vanes Left-Right?listYes
Enable use of bit-type Vanes L-R objects (for Control)listNo
Enable use of bit-type Vanes L-R objects (for Status)listNo
Enable "Vanes L-R Swing" objects (for Control and Status)listYes
Enable use of Text object for Vanes L-RlistNo
ASCII strings shown in comm object "Status_ Vanes L-R Text"text<< 14-byte string values >>
> String when vanes L-R in AUTOtextL-R AUTO
> String when vanes L-R in POS 1textL-R POS 1
> String when vanes L-R in POS 2textL-R POS 2
> String when vanes L-R in POS 3textL-R POS 3
> String when vanes L-R in POS 4textL-R POS 4
> String when vanes L-R in POS 5textL-R POS 5
> String when vanes L-R in SWINGtextL-R SWING
AC unit has Humidifier (see docum. for your indoor unit)listNo
Available intensities in Indoor Unit (see docum. for your indoor unit)listYes
DPT object type for HumidifyinglistScaling [DPT_5.001]
Enable use of +/- object for HumidifyinglistNo
> DPT type for +/- Humidifying objectlist0-Decrease / 1-Increase [DPT_1.007]
> Rollover Humi. at upper/lower limit (when controlling with +/- obj)listNo
Enable use of bit-type Humidif. objects (for Control)listNo
Enable use of bit-type Humidif. objects (for Status)listNo
Enable use of Text obj for HumidifyinglistNo
ASCII strings shown in comm object "Status_ Humidifying Text"text<< 14-byte string values >>
> String when Humidifying is OFFtextHUMI OFF
> String when Humidifying is LOWtextHUMI LOW
> String when Humidifying is MIDtextHUMI MID
> String when Humidifying is HIGHtextHUMI HIGH
> String when Humidifying is CONT.textHUMI CONT
Enable use of Legacy_ object for Humi. (compatible with old vers of XXACKNX1)listNo
Periodic sending of "Status_ AC Setp" (in seconds;0=No periodic sending)unsignedInt 0…2550
Transmission of "Status_ AC Ambient Ref Temp"listOnly on change
> "Status_ AC Ambient Ref Temp" periodic sending time (in sec)unsignedInt 1…255180
Enable use of +/- obj for Setpoint TemplistNo
> DPT type for +/- Setp Temp objectlist0-Decrease / 1-Increase [DPT_1.007]
> [+/-] step sizelist1.0 ºC
Enable limits on Setpoint Temperature (applies only to Heat and Cool modes)listNo
> Lower limitlist16 ºC (can't be reached in Cool mode)
> Upper limitlist30 ºC
Ambient temp. ref. is provided from KNX (carefully read User Guide if enabled)listNo
Enable use of sceneslistNo
Scenes can be stored from KNX buslistNo
> Enable use of bit objects for storing scenes (from bus)listNo
Enable use of bit objects for scene executionlistNo
Scene 1 presetlistNo
> Scene 1 / Value for On-Offlist(unchanged)
> Scene 1 / Value for Modelist(unchanged)
> Scene 1 / Value for Fan Speedlist(unchanged)
> Scene 1 / Value for Vanes U-D (if available)list(unchanged)
> Scene 1 / Value for Vanes L-R (if available)list(unchanged)
> Scene 1 / Value for Setpoint Templist(unchanged)
> Scene 1 / Value for Remote Locklist(unchanged)
> Scene 1 / Value for Humidifying (if available)list(unchanged)
Scene 2 presetlistNo
> Scene 2 / Value for On-Offlist(unchanged)
> Scene 2 / Value for Modelist(unchanged)
> Scene 2 / Value for Fan Speedlist(unchanged)
> Scene 2 / Value for Vanes U-D (if available)list(unchanged)
> Scene 2 / Value for Vanes L-R (if available)list(unchanged)
> Scene 2 / Value for Setpoint Templist(unchanged)
> Scene 2 / Value for Remote Locklist(unchanged)
> Scene 2 / Value for Humidifying (if available)list(unchanged)
Scene 3 presetlistNo
> Scene 3 / Value for On-Offlist(unchanged)
> Scene 3 / Value for Modelist(unchanged)
> Scene 3 / Value for Fan Speedlist(unchanged)
> Scene 3 / Value for Vanes U-D (if available)list(unchanged)
> Scene 3 / Value for Vanes L-R (if available)list(unchanged)
> Scene 3 / Value for Setpoint Templist(unchanged)
> Scene 3 / Value for Remote Locklist(unchanged)
> Scene 3 / Value for Humidifying (if available)list(unchanged)
Scene 4 presetlistNo
> Scene 4 / Value for On-Offlist(unchanged)
> Scene 4 / Value for Modelist(unchanged)
> Scene 4 / Value for Fan Speedlist(unchanged)
> Scene 4 / Value for Vanes U-D (if available)list(unchanged)
> Scene 4 / Value for Vanes L-R (if available)list(unchanged)
> Scene 4 / Value for Setpoint Templist(unchanged)
> Scene 4 / Value for Remote Locklist(unchanged)
> Scene 4 / Value for Humidifying (if available)list(unchanged)
Scene 5 presetlistNo
> Scene 5 / Value for On-Offlist(unchanged)
> Scene 5 / Value for Modelist(unchanged)
> Scene 5 / Value for Fan Speedlist(unchanged)
> Scene 5 / Value for Vanes U-D (if available)list(unchanged)
> Scene 5 / Value for Vanes L-R (if available)list(unchanged)
> Scene 5 / Value for Setpoint Templist(unchanged)
> Scene 5 / Value for Remote Locklist(unchanged)
> Scene 5 / Value for Humidifying (if available)list(unchanged)
Enable use of Open Window / Switch off timeout functionlistNo
> AC switch-off timeout (min)unsignedInt 0…3010
> DPT for Window / Switch-off timeoutlist0-Stop / 1-Start Timeout [DPT_1.010]
> Disallow On/Off operation while window is OpenlistNo
> Disallow On/Off operation while timeout is elapsedlistNo
> Reload last On/Off val once timeout is stoppedlistNo
> Reload last On/Off val once window is ClosedlistNo
Enable use of Occupancy functionlistNo
> Timeout to apply action (minutes)unsignedInt 0…18020
> Action after timeout elapsedlistSwitch-Off AC
> Temp delta decrease (HEAT) or increase (COOL) (ºC)list2.0 ºC
> Enable secondary timeoutlistNo
> Timeout to apply action (min)unsignedInt 1…18020
> Action after timeout elapsedlistSwitch-Off AC
> Temp delta dec (HEAT) or inc (COOL) (ºC)list3.0 ºC
> Disallow On/Off operation while not OccupiedlistNo
> Reload last On/Off value when OccupiedlistNo
Enable use of Sleep functionlistNo
> Sleep function switch-off timeout (minutes)unsignedInt 0…18060
Enable use of Input 1listNo
> Contact typelistNO: Normally Open
> Debounce timelist50 ms
> Disabling functionlistNo
> Reset Input when enablinglistNo
> FunctionlistSwitching
> Send telegram after bus recoverylistNo action
> Sending delay after bus recovery (seconds)unsignedInt 0…25510
> Value on raising edge (contact activated)listNo action
> Scene when contact is activated (needs to be defined)listScene 1
> Mode for short (long) operationlistToggle: On/Off (increase/decrease)
> OperationlistToggle (Up/Down)
> DPT to be sentlistDPT 5.010 (1byte)
> Value on falling edge (contact deactivated)listNo action
> Increasing steplist+ 25 %
> MethodlistStep-Move-Step
> Cyclical sendinglistNever
> Decreasing steplist- 25 %
> Short/long operation limit (x100ms)unsignedInt 1…25510
> Period for cyclical sending (seconds)unsignedInt 1…6553510
> Vanes adjustment time (x100ms)unsignedInt 1…25510
> Value on raising edge (when contact activated)unsignedInt 0…2550
> Value on raising edge (when contact activated)unsignedInt 0…655350
> Value on raising edge (when contact activated)signedInt -32768…327670
> Value on rais. edge (x0.1ºC) (when contact activated)signedInt -2730…3276250
> Value on raising edge (when contact activated)unsignedInt 0…42949672950
> Cycl. send. period in long oper. (x100ms)(0-No cyclical send.)unsignedInt 0…2550
Enable use of Input 2listNo
Enable use of Input 3listNo
Enable use of Input 4listNo
Hide items?!listYes

Version history

ApplicationApp noFingerprintFirst seenSizeFile
0110 LGRCKNX1i T10V14 1.4 latest$001011642026-11-25147 KBDownload

About this file

This is the official ETS product database for the Intesis LG RC interface, 4 binary inputs (LG-RC-KNX-1i), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.