KNX Database
Intesis HI-AW-KNX-1 HI AW Interface

HI AW Interface HI-AW-KNX-1

Intesis · Order number HI-AW-KNX-1 · Communication › Interfaces › Hitachi Air to Water Interfaces

Download .knxprod HIAWKNX1 T1BV12 1.2 · 99 KB

Product

ManufacturerIntesis
Product nameHI AW Interface
Order numberHI-AW-KNX-1
HardwareHI AW Interface
MediumTwisted Pair
Bus current (mA)6
Rail mountedNo
RegistrationCertified · 2014-01-31
Languageses-ES, en-US
Catalog entryM-0077_H-HI.2DAW.2DKNX.2D1-16_HP-001B-12-7905_CI-HI.2DAW.2DKNX.2D1-1
Fingerprint7905
SHA-256ac60df4f443f0cc2c92f4f41e700b78b2c1ff38b74989ad09a8140c72dd0f7b3
First seen2026-11-25
Markets69 markets

Application program: HIAWKNX1 T1BV12 1.2

Application number$001B
Version1.2
Mask versionMV-0025 (2.5)
KNX Data SecureNo
Minimum ETS version4.0
Parameters33
Group objects145
Group objects (145)
NoNameFunctionSizeDPTFlags
0Control_ Unit Run/Stop [DPT_1.010]0-Stop;1-Run1 Bit1.10 start/stopCW
1Control_ Unit Mode [DPT_ 20.105]0-Auto;1-Heat;3-Cool1 Byte20.105 HVAC control modeCW
2Control_ Unit Mode Cool/Heat [DPT_ 1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCW
3Control_ Unit Mode Auto [DPT_ 1.002]1-Set AUTO Mode1 Bit1.2 booleanCW
4Control_ Unit Mode Heat [DPT_ 1.002]1-Set HEAT Mode1 Bit1.2 booleanCW
5Control_ Unit Mode Cool [DPT_ 1.002]1-Set COOL Mode1 Bit1.2 booleanCW
6Control_ C1 Run/Stop [DPT_1.010]0-Stop;1-Run1 Bit1.10 start/stopCW
7Control_ C1 Heat OTC Mode Off [DPT_1.002]1-Set OTC Mode OFF1 Bit1.2 booleanCW
8Control_ C1 Heat OTC Mode Points [DPT_1.002]1-Set OTC Mode POINTS1 Bit1.2 booleanCW
9Control_ C1 Heat OTC Mode Grad [DPT_1.002]1-Set OTC Mode GRAD1 Bit1.2 booleanCW
10Control_ C1 Heat OTC Mode Fix [DPT_1.002]1-Set OTC Mode FIX1 Bit1.2 booleanCW
11Control_ C1 Cool OTC Mode Off [DPT_1.002]1-Set OTC Mode OFF1 Bit1.2 booleanCW
12Control_ C1 Cool OTC Mode Points [DPT_1.002]1-Set OTC Mode POINTS1 Bit1.2 booleanCW
13Control_ C1 Cool OTC Mode Fix [DPT_1.002]1-Set OTC Mode FIX1 Bit1.2 booleanCW
14Control_ C1 Water Heat Setpoint [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
15Control_ C1 Water Cool Setpoint [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
16Control_ C1 ECO Mode [DPT_1.002]0-Comfort;1-Eco1 Bit1.2 booleanCW
17Control_ C1 ECO Heat Offset Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
18Control_ C1 ECO Cool Offset Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
19Control_ C1 Thermo Setpoint Temp [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
20Control_ C1 Ambient Temp [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
21Control_ C2 Run/Stop [DPT_1.010]0-Stop;1-Run1 Bit1.10 start/stopCW
22Control_ C2 Heat OTC Mode Off [DPT_1.002]1-Set OTC Mode OFF1 Bit1.2 booleanCW
23Control_ C2 Heat OTC Mode Points [DPT_1.002]1-Set OTC Mode POINTS1 Bit1.2 booleanCW
24Control_ C2 Heat OTC Mode Grad [DPT_1.002]1-Set OTC Mode GRAD1 Bit1.2 booleanCW
25Control_ C2 Heat OTC Mode Fix [DPT_1.002]1-Set OTC Mode FIX1 Bit1.2 booleanCW
26Control_ C2 Cool OTC Mode Off [DPT_1.002]1-Set OTC Mode OFF1 Bit1.2 booleanCW
27Control_ C2 Cool OTC Mode Points [DPT_1.002]1-Set OTC Mode POINTS1 Bit1.2 booleanCW
28Control_ C2 Cool OTC Mode Fix [DPT_1.002]1-Set OTC Mode FIX1 Bit1.2 booleanCW
29Control_ C2 Water Heat Setpoint [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
30Control_ C2 Water Cool Setpoint [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
31Control_ C2 ECO Mode [DPT_1.002]0-Comfort;1-Eco1 Bit1.2 booleanCW
32Control_ C2 ECO Heat Offset Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
33Control_ C2 ECO Cool Offset Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
34Control_ C2 Thermo Setpoint [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
35Control_ C2 Ambient Temp [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
36Control_ DHW Run/Stop [DPT_1.010]0-Stop;1-Run1 Bit1.10 start/stopCW
37Control_ DHW Boost [DPT_1.002]1-Request1 Bit1.2 booleanCW
38Control_ DHW High Demand Mode [DPT_1.002]0-Standard;1-High1 Bit1.2 booleanCW
39Control_ DHW Setpoint [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
40Control_ SwimPool Run/Stop [DPT_1.010]0-Stop;1-Run1 Bit1.10 start/stopCW
41Control_ SwimPool Setpoint [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
42Control_ AntiLeg Run/Stop [DPT_1.010]0-Stop;1-Run1 Bit1.10 start/stopCW
43Control_ AntiLeg Setpoint [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CW
44Control_ KNX Blocks/Enables Menu [DPT_1.003]0-Block;1-Enable1 Bit1.3 enableCW
45Status_ Unit Run/Stop [DPT_1.010]0-Stop;1-Run1 Bit1.10 start/stopCRT
46Status_ Unit Mode [DPT_20.105]1-Heat;3-Cool1 Byte20.105 HVAC control modeCRT
47Status_ Unit Mode Cool/Heat [DPT_1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCRT
48Status_ Unit Mode Auto [DPT_1.002]1-AUTO Mode is active1 Bit1.2 booleanCRT
49Status_ Unit Mode Heat [DPT_1.002]1-HEAT Mode is active1 Bit1.2 booleanCRT
50Status_ Unit Mode Cool [DPT_1.002]1-COOL Mode is active1 Bit1.2 booleanCRT
51Status_ C1 Run/Stop [DPT_1.010]0-Stop;1-Run1 Bit1.10 start/stopCRT
52Status_ C1 Heat OTC Mode Off [DPT_1.002]1-OTC Mode OFF is set1 Bit1.2 booleanCRT
53Status_ C1 Heat OTC Mode Points [DPT_1.002]1-OTC Mode POINTS is set1 Bit1.2 booleanCRT
54Status_ C1 Heat OTC Mode Grad [DPT_1.002]1-OTC Mode GRAD is set1 Bit1.2 booleanCRT
55Status_ C1 Heat OTC Mode Fix [DPT_1.002]1-OTC Mode FIX is set1 Bit1.2 booleanCRT
56Status_ C1 Cool OTC Mode Off [DPT_1.002]1-OTC Mode OFF is set1 Bit1.2 booleanCRT
57Status_ C1 Cool OTC Mode Points [DPT_1.002]1-OTC Mode POINTS is set1 Bit1.2 booleanCRT
58Status_ C1 Cool OTC Mode Fix [DPT_1.002]1-OTC Mode FIX is set1 Bit1.2 booleanCRT
59Status_ C1 Water Heat Setpoint [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
60Status_ C1 Water Cool Setpoint [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
61Status_ C1 ECO Mode [DPT_1.002]0-Comfort;1-Eco1 Bit1.2 booleanCRT
62Status_ C1 ECO Heat Offset Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
63Status_ C1 ECO Cool Offset Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
64Status_ C1 Thermo Setpoint Temp [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
65Status_ C1 Ambient Temp [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
66Status_ C1 Wireless Setpoint Temp [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
67Status_ C1 Wireless Ambient Temp [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
68Status_ C2 Run/Stop [DPT_1.010]0-Stop;1-Run1 Bit1.10 start/stopCRT
69Status_ C2 Heat OTC Mode Off [DPT_1.002]1-OTC Mode OFF is set1 Bit1.2 booleanCRT
70Status_ C2 Heat OTC Mode Points [DPT_1.002]1-OTC Mode POINTS is set1 Bit1.2 booleanCRT
71Status_ C2 Heat OTC Mode Grad [DPT_1.002]1-OTC Mode GRAD is set1 Bit1.2 booleanCRT
72Status_ C2 Heat OTC Mode Fix [DPT_1.002]1-OTC Mode FIX is set1 Bit1.2 booleanCRT
73Status_ C2 Cool OTC Mode Off [DPT_1.002]1-OTC Mode OFF is set1 Bit1.2 booleanCRT
74Status_ C2 Cool OTC Mode Points [DPT_1.002]1-OTC Mode POINTS is set1 Bit1.2 booleanCRT
75Status_ C2 Cool OTC Mode Fix [DPT_1.002]1-OTC Mode FIX is set1 Bit1.2 booleanCRT
76Status_ C2 Water Heat Setpoint [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
77Status_ C2 Water Cool Setpoint [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
78Status_ C2 ECO Mode [DPT_1.002]0-Comfort;1-Eco1 Bit1.2 booleanCRT
79Status_ C2 ECO Heat Offset Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
80Status_ C2 ECO Cool Offset Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
81Status_ C2 Thermo Setpoint [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
82Status_ C2 Ambient Temp [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
83Status_ C2 Wireless Setpoint Temp [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
84Status_ C2 Wireless Ambient Temp [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
85Status_ DHW Run/Stop [DPT_1.010]0-Stop;1-Run1 Bit1.10 start/stopCRT
86Status_ DHW Boost [DPT_1.002]0-Not requested;1-Requested1 Bit1.2 booleanCRT
87Status_ DHW High Demand Mode [DPT_1.002]0-Standard;1-High1 Bit1.2 booleanCRT
88Status_ DHW Setpoint [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
89Status_ DHW Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
90Status_ SwimPool Run/Stop [DPT_1.010]0-Stop;1-Run1 Bit1.10 start/stopCRT
91Status_ SwimPool Setpoint [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
92Status_ SwimPool Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
93Status_ AntiLeg Run/Stop [DPT_1.010]0-Stop;1-Run1 Bit1.10 start/stopCRT
94Status_ AntiLeg Setpoint [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
95Status_ KNX Blocks/Enables Menu [DPT_1.003]0-Block;1-Enable1 Bit1.3 enableCRT
96Status_ Error/Alarm [DPT_1.005]0-No alarm;1-Alarm1 Bit1.5 alarmCRT
97Status_ Error Code [2byte]0-No error/Any other see man.2 BytesCRT
98Status_ Operation State Unit On/Off [DPT_1.001]0-Off;1-On1 Bit1.1 switchCRT
99Status_ Operation State Cool Demand [DPT_1.001]0-Off;1-On1 Bit1.1 switchCRT
100Status_ Operation State Cool Thermo [DPT_1.001]0-Off;1-On1 Bit1.1 switchCRT
101Status_ Operation State Heat Demand [DPT_1.001]0-Off;1-On1 Bit1.1 switchCRT
102Status_ Operation State Heat Thermo [DPT_1.001]0-Off;1-On1 Bit1.1 switchCRT
103Status_ Operation State DHW [DPT_1.001]0-Off;1-On1 Bit1.1 switchCRT
104Status_ Operation State SwimPool [DPT_1.001]0-Off;1-On1 Bit1.1 switchCRT
105Status_ Operation State Alarm [DPT_1.005]0-No alarm;1-Alarm1 Bit1.5 alarmCRT
106Status_ Outdoor Ambient Temp [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
107Status_ Second Ambient Temp [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
108Status_ Water Inlet Temp [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
109Status_ Water Outlet Temp [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
110Status_ Defrost Operation [DPT_1.001]0-Off;1-On1 Bit1.1 switchCRT
111Status_ Water Pump 1 Operation [DPT_1.001]0-Off;1-On1 Bit1.1 switchCRT
112Status_ Water Pump 2 Operation [DPT_1.001]0-Off;1-On1 Bit1.1 switchCRT
113Status_ Water Pump 3 Operation [DPT_1.001]0-Off;1-On1 Bit1.1 switchCRT
114Status_ Disch. Gas Temp [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
115Status_ Suct. Gas Temp [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
116Status_ Gas Temp THMg [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
117Status_ Liquid Temp THMI [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
118Status_ Water Outlet Temp 3 [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
119Status_ Outdoor AmbAvg Temp [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
120Status_ Inv Oper Freq [DPT_14.033]Hz4 Bytes14.33 frequency (Hz)CRT
121Status_ Indoor Exp. Valve Opening [DPT_5.001]%1 Byte5.1 percentage (0..100%)CRT
122Status_ Outdoor Exp. Valve Opening [DPT_5.001]%1 Byte5.1 percentage (0..100%)CRT
123Status_ Mixing Valve Position [DPT_5.001]%1 Byte5.1 percentage (0..100%)CRT
124Status_ Compressor Run Current [DPT_9.021]mA2 Bytes9.21 current (mA)CRT
125Status_ Water Flow [DPT_13.002]m3/h4 Bytes13.2 flow rate (m³/h)CRT
126Status_ Water Pump Speed [DPT_5.001]%1 Byte5.1 percentage (0..100%)CRT
127Status_ Unit Model Yutaki S [DPT_1.002]1-Model is Yutaki S1 Bit1.2 booleanCRT
128Status_ Unit Model Yutaki S Combi [DPT_1.002]1-Model is Yutaki S Combi1 Bit1.2 booleanCRT
129Status_ Unit Model Yutaki S80 [DPT_1.002]1-Model is Yutaki S801 Bit1.2 booleanCRT
130Status_ Unit Model Yutaki M [DPT_1.002]1-Model is Yutaki M1 Bit1.2 booleanCRT
131Status_ PCB Software Version [DPT_217.001]Software version2 Bytes217.1 DPT versionCRT
132Status_ LCD Software Version [DPT_217.001]Software version2 Bytes217.1 DPT versionCRT
133Status_ Instant Capacity [DPT_13.013]kWh4 Bytes13.13 active energy (kWh)CRT
134Status_ Unit Power Consumption [DPT_13.013]kWh4 Bytes13.13 active energy (kWh)CRT
135Status_ Disch. Gas Temp R134A [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
136Status_ Suct. Gas Temp R134A [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
137Status_ Liquid Gas Temp R134A [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
138Status_ Evap. Gas Temp R134A [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
139Status_ Disch. Pressure R134A [DPT_14.058]Pa4 Bytes14.58 pressure (Pa)CRT
140Status_ Suct. Pressure R134A [DPT_14.058]Pa4 Bytes14.58 pressure (Pa)CRT
141Status_ Inv Oper Freq R134A [DPT_14.033]Hz4 Bytes14.33 frequency (Hz)CRT
142Status_ Indoor Exp. Valve Open R134A [DPT_5.001]%1 Byte5.1 percentage (0..100%)CRT
143Status_ Compressor Run Current R134A [DPT_9.021]mA2 Bytes9.21 current (mA)CRT
144Status_ Error Code R134A [1byte]HI error code1 ByteCRT
Parameters (13)
ParameterTypeDefault
Download latest database entry for this product and its User Manual from:texthttp://www.intesisbox.com
ModellistYutaki series 2015 or older
Outdoor Unit AddressunsignedInt 0…630
Indoor Unit AddressunsignedInt 0…630
System is Yutaki S80listNo
System working modelistWater
2nd circuit (C2) is availablelistNo
DHW is available (Domestic Hot Water)listNo
Swimming pool is availablelistNo
Show extra information objects (for status)listNo
virtAux_conditionlistNo
virt_DUMMY_checkConditionslistNo
virt_DUMMY_showComObjectslistNo

Version history

ApplicationApp noFingerprintFirst seenSizeFile
HIAWKNX1 T1BV12 1.2 latest$001B79052026-11-2599 KBDownload

About this file

This is the official ETS product database for the Intesis HI AW Interface (HI-AW-KNX-1), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Intesis

All Intesis products