KNX Interface for Toshiba AC BMS-IFKX0TLR-E

Intesis · Order number BMS-IFKX0TLR-E · Communication › Interfaces › Toshiba Air Conditioning Interfaces

Download .knxprod BMS-IFKX0TLR-E V10 1.0 · 115 KB

Product

ManufacturerIntesis
Product nameKNX Interface for Toshiba AC
Order numberBMS-IFKX0TLR-E
HardwareBMS-IFKX0TLR-E
MediumTwisted Pair
Bus current (mA)8
Rail mountedNo
RegistrationCertified · 2018-08-09
Languagesen-US
Catalog entryM-0077_H-BMS.2DIFKX0TLR.2DE-0_HP-0028-10-2B34_CI-BMS.2DIFKX0TLR.2DE-1
Fingerprint2B34
SHA-256314b3d808546fed1b54097a3eedde885acd6a81091ae9c4fe664faff475f0af5
First seen2026-11-25
Markets69 markets

Application program: BMS-IFKX0TLR-E V10 1.0

Application number$0028
Version1.0
Mask versionMV-0025 (2.5)
KNX Data SecureNo
Minimum ETS version4.0
Parameters120
Group objects218
Group objects (218)
NoNameFunctionSizeDPTFlags
0Control_ On/Off [DPT_1.001]0-Off;1-On1 Bit1.1 switchCWTU
1Control_ Mode [DPT_20.105]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 Byte20.105 HVAC control modeCWTU
2Control_ Mode Cool/Heat [DPT_1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCWTU
3Control_ Mode Cool & On [DPT_5.001]0%-Off;0.1%-100%-On+Cool1 Byte5.1 percentage (0..100%)CWTU
4Control_ Mode Heat & On [DPT_5.001]0%-Off;0.1%-100%-On+Heat1 Byte5.1 percentage (0..100%)CWTU
5Control_ Mode Auto [DPT_1.002]1-Set AUTO mode1 Bit1.2 booleanCWTU
6Control_ Mode Heat [DPT_1.002]1-Set HEAT mode1 Bit1.2 booleanCWTU
7Control_ Mode Cool [DPT_1.002]1-Set COOL mode1 Bit1.2 booleanCWTU
8Control_ Mode Fan [DPT_1.002]1-Set FAN mode1 Bit1.2 booleanCWTU
9Control_ Mode Dry [DPT_1.002]1-Set DRY mode1 Bit1.2 booleanCWTU
10Control_ Mode -/+ [DPT_1.007]0-Decrease;1-Increase1 Bit1.7 stepCW
11Control_ Mode +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
12Control_ Fan Speed / N Speeds [DPT_5.001]Thresholds: 100*(n+0'5)/N %1 Byte5.1 percentage (0..100%)CWTU
13Control_ Fan Speed / N Speeds [DPT_5.010] Speed values: 1...N1 Byte5.10 counter pulses (0..255)CWTU
14Control_ Fan Speed Man/Auto [DPT_1.002]0-Fanspeed 1;1-Auto1 Bit1.2 booleanCWTU
15Control_ Fan Speed 1 [DPT_1.002]1-Set Fanspeed 11 Bit1.2 booleanCWTU
16Control_ Fan Speed 2 [DPT_1.002]1-Set Fanspeed 21 Bit1.2 booleanCWTU
17Control_ Fan Speed 3 [DPT_1.002]1-Set Fanspeed 31 Bit1.2 booleanCWTU
18Control_ Fan Speed 4 [DPT_1.002]1-Set Fanspeed 41 Bit1.2 booleanCWTU
19Control_ Fan Speed 5 [DPT_1.002]1-Set Fanspeed 51 Bit1.2 booleanCWTU
20Control_ Fan Speed -/+ [DPT_1.007]0-Decrease;1-Increase1 Bit1.7 stepCW
21Control_ Fan Speed +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
22Control_ Louver / 5 Pos [DPT_5.001]Thresholds: 30, 50, 70 and 90%1 Byte5.1 percentage (0..100%)CWTU
23Control_ Louver / 5 Pos [DPT_5.010]Position values: 1,2,3,4,51 Byte5.10 counter pulses (0..255)CWTU
24Control_ Louver Stop [DPT_1.002]1-Stop1 Bit1.2 booleanCWTU
25Control_ Louver Pos 1 [DPT_1.002]1-Set Position 11 Bit1.2 booleanCWTU
26Control_ Louver Pos 2 [DPT_1.002]1-Set Position 21 Bit1.2 booleanCWTU
27Control_ Louver Pos 3 [DPT_1.002]1-Set Position 31 Bit1.2 booleanCWTU
28Control_ Louver Pos 4 [DPT_1.002]1-Set Position 41 Bit1.2 booleanCWTU
29Control_ Louver Pos 5 [DPT_1.002]1-Set Position 51 Bit1.2 booleanCWTU
30Control_ Louver Swing [DPT_1.002]1-Swing1 Bit1.2 booleanCWTU
31Control_ Louver -/+ [DPT_1.007]0-Decrease;1-Increase1 Bit1.7 stepCW
32Control_ Louver +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
33Control_ Louver 4-way-1 / 5 Pos [DPT_5.001] Thresholds: 30, 50, 70 and 90%1 Byte5.1 percentage (0..100%)CWTU
34Control_ Louver 4-way-1 / 5 Pos [DPT_5.010]Position values: 1,2,3,4,51 Byte5.10 counter pulses (0..255)CWTU
35Control_ Louver 4-way-1 Stop [DPT_1.002] 1-Stop1 Bit1.2 booleanCWTU
36Control_ Louver 4-way-1 Swing [DPT_1.002] 1-Swing1 Bit1.2 booleanCWTU
37Control_ Louver 4-way-1 -/+ [DPT_1.007]0-Decrease;1-Increase1 Bit1.7 stepCW
38Control_ Louver 4-way-1 +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
39Control_ Louver 4-way-2 / 5 Pos [DPT_5.001]Thresholds: 30, 50, 70 and 90%1 Byte5.1 percentage (0..100%)CWTU
40Control_ Louver 4-way-2 / 5 Pos [DPT_5.010]Position values: 1,2,3,4,51 Byte5.10 counter pulses (0..255)CWTU
41Control_ Louver 4-way-2 Stop [DPT_1.002]1-Stop1 Bit1.2 booleanCWTU
42Control_ Louver 4-way-2 Swing [DPT_1.002]1-Swing1 Bit1.2 booleanCWTU
43Control_ Louver 4-way-2 -/+ [DPT_1.007]0-Decrease;1-Increase1 Bit1.7 stepCW
44Control_ Louver 4-way-2 +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
45Control_ Louver 4-way-3 / 5 Pos [DPT_5.001]Thresholds: 30, 50, 70 and 90%1 Byte5.1 percentage (0..100%)CWTU
46Control_ Louver 4-way-3 / 5 Pos [DPT_5.010]Position values: 1,2,3,4,51 Byte5.10 counter pulses (0..255)CWTU
47Control_ Louver 4-way-3 Stop [DPT_1.002]1-Stop1 Bit1.2 booleanCWTU
48Control_ Louver 4-way-3 Swing [DPT_1.002]1-Swing1 Bit1.2 booleanCWTU
49Control_ Louver 4-way-3 -/+ [DPT_1.007]0-Decrease;1-Increase1 Bit1.7 stepCW
50Control_ Louver 4-way-3 +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
51Control_ Louver 4-way-4 / 5 Pos [DPT_5.001]Thresholds: 30, 50, 70 and 90%1 Byte5.1 percentage (0..100%)CWTU
52Control_ Louver 4-way-4 / 5 Pos [DPT_5.010]Position values: 1,2,3,4,51 Byte5.10 counter pulses (0..255)CWTU
53Control_ Louver 4-way-4 Stop [DPT_1.002]1-Stop1 Bit1.2 booleanCWTU
54Control_ Louver 4-way-4 Swing [DPT_1.002]1-Swing1 Bit1.2 booleanCWTU
55Control_ Louver 4-way-4 -/+ [DPT_1.007]0-Decrease;1-Increase1 Bit1.7 stepCW
56Control_ Louver 4-way-4 +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
57Control_ Temperature Setting [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CWTU
58Control_ Temperature Setting -/+ [DPT_1.007]0-Decrease;1-Increase1 Bit1.7 stepCW
59Control_ Temperature Setting +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
60Control_ AutoCooling Temperature Setting [9.001]ºC2 Bytes9.1 temperature (°C)CWTU
61Control_ AutoCooling Temperature Setting -/+ [DPT_1.007]0-Decrease;1-Increase1 Bit1.7 stepCW
62Control_ AutoCooling Temperature Setting +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
63Control_ AutoHeatingTemperature Setting [9.001]ºC2 Bytes9.1 temperature (°C)CWTU
64Control_ AutoHeating Temperature Setting -/+ [DPT_1.007]0-Decrease;1-Increase1 Bit1.7 stepCW
65Control_ AutoHeating Temperature Setting +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
66Control_ Permit/Prohibit control of Remote Controller ALL [DPT_1.002]0-Permit; 1-Prohibit1 Bit1.2 booleanCWTU
67Control_ Permit/Prohibit control of Remote Controller On/Off [DPT_1.002]0-Permit; 1-Prohibit1 Bit1.2 booleanCWTU
68Control_ Permit/Prohibit control of Remote Controller Mode [DPT_1.002]0-Permit; 1-Prohibit1 Bit1.2 booleanCWTU
69Control_ Permit/Prohibit control of Remote Controller Temperature Setting [DPT_1.002]0-Permit; 1-Prohibit1 Bit1.2 booleanCWTU
70Control_ Permit/Prohibit control of Remote Controller FAN speed [DPT_1.002]0-Permit; 1-Prohibit1 Bit1.2 booleanCWTU
71Control_ Permit/Prohibit control of Remote Controller Louver [DPT_1.002]0-Permit; 1-Prohibit1 Bit1.2 booleanCWTU
72Control_ Reset Filter [DPT_1.015]1-Reset filter1 Bit1.15 resetCWTU
73Control_ Save Operation Normal Operation [DPT_1.002]1-Activate no save 1 Bit1.2 booleanCWTU
74Control_ Save Operation 100-50% Operation [DPT_1.002]1-Activate 1..49% save1 Bit1.2 booleanCWTU
75Control_ Save Operation 50% Operation [DPT_1.002]1-Activate 50% save1 Bit1.2 booleanCWTU
76Control_ Save Operation Thermo Off [DPT_1.002]1-Activate 100% save1 Bit1.2 booleanCWTU
77Control_ Ventilation On/Off [DPT_1.001]0-Off; 1-On1 Bit1.1 switchCWTU
78Control_ Ventilation Mode Heat Exchange [DPT_1.002]1-Activate Ventilation Heat Exchange Mode1 Bit1.2 booleanCWTU
79Control_ Ventilation Mode Bypass [DPT_1.002]1-Activate Ventilation Bypass Mode1 Bit1.2 booleanCWTU
80Control_ Ventilation Mode Automatic [DPT_1.002]1-Activate Ventilation Automatic Mode1 Bit1.2 booleanCWTU
81Control_ Ventilation Mode -/+ [DPT_1.007]0-Decrease;1-Increase1 Bit1.7 stepCW
82Control_ Ventilation Mode +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
83Control_ Ventilation Air Volume Stop [DPT_1.002]1-Activate Ventilation air volume stop1 Bit1.2 booleanCWTU
84Control_ Ventilation Air Volume H [DPT_1.002]1-Activate Ventilation air volume H1 Bit1.2 booleanCWTU
85Control_ Ventilation Air Volume L [DPT_1.002]1-Activate Ventilation air volume L1 Bit1.2 booleanCWTU
86Control_ Ventilation Air Volume Imbalance [DPT_1.002]1-Activate Ventilation air volume imbalance1 Bit1.2 booleanCWTU
87Control_ Ventilation Air Volume -/+ [DPT_1.007]0-Decrease;1-Increase1 Bit1.7 stepCW
88Control_ Ventilation Air Volume +/- [DPT_1.008]0-Up;1-Down1 Bit1.8 up/downCW
89Control_ Soft Cooling [DPT_1.001]0 - Off; 1-On1 Bit1.1 switchCWTU
90Status_ On/Off [DPT_1.001]0-Off;1-On1 Bit1.1 switchCRT
91Status_ Mode [DPT_20.105]0-Aut;1-Hea;3-Coo;9-Fan;14-Dry1 Byte20.105 HVAC control modeCRT
92Status_ Mode Cool/Heat [DPT_1.100]0-Cool;1-Heat1 Bit1.100 heating/coolingCRT
93Status_ Mode Auto [DPT_1.002]1-AUTO mode is active1 Bit1.2 booleanCRT
94Status_ Mode Heat [DPT_1.002]1-HEAT mode is active1 Bit1.2 booleanCRT
95Status_ Mode Cool [DPT_1.002]1-COOL mode is active1 Bit1.2 booleanCRT
96Status_ Mode Fan [DPT_1.002]1-FAN mode is active1 Bit1.2 booleanCRT
97Status_ Mode Dry [DPT_1.002]1-DRY mode is active1 Bit1.2 booleanCRT
98Status_ Mode AutoHeat [DPT_1.002]1-AUTOHEAT mode is active1 Bit1.2 booleanCRT
99Status_ Mode AutoCool [DPT_1.002]1-AUTOCOOL mode is active1 Bit1.2 booleanCRT
100Status_ Mode Text [DPT_16.001]ASCII String14 Bytes16.0 Character String (ASCII)CRT
101Status_ Fan Speed / N Speeds [DPT_5.001]100*n/N %1 Byte5.1 percentage (0..100%)CRT
102Status_ Fan Speed / N Speeds [DPT_5.010] Speed values: 1...N1 Byte5.10 counter pulses (0..255)CRT
103Status_ Fan Speed Man/Auto [DPT_1.002]0-Manual;1-Auto1 Bit1.2 booleanCRT
104Status_ Fan Speed Stop [DPT_1.002]1-Fan Stop1 Bit1.2 booleanCRT
105Status_ Fan Speed LL [DPT_1.002]1-Fan Extra Low1 Bit1.2 booleanCRT
106Status_ Fan Speed 1 [DPT_1.002]1-Fan in speed 11 Bit1.2 booleanCRT
107Status_ Fan Speed 2 [DPT_1.002]1-Fan in speed 21 Bit1.2 booleanCRT
108Status_ Fan Speed 3 [DPT_1.002]1-Fan in speed 31 Bit1.2 booleanCRT
109Status_ Fan Speed 4 [DPT_1.002]1-Fan in speed 41 Bit1.2 booleanCRT
110Status_ Fan Speed 5 [DPT_1.002]1-Fan in speed 51 Bit1.2 booleanCRT
111Status_ Fan Speed Text [DPT_16.001]ASCII String14 Bytes16.0 Character String (ASCII)CRT
112Status_ Louver / 5 Pos [DPT_5.001]20%, 40%, 60%, 80% and 100%1 Byte5.1 percentage (0..100%)CRT
113Status_ Louver / 5 Pos [DPT_5.010]Position values: 1,2,3,4,51 Byte5.10 counter pulses (0..255)CRT
114Status_ Louver Stop [DPT_1.002]1-Louver Stop1 Bit1.2 booleanCRT
115Status_ Louver Pos 1 [DPT_1.002]1-Louver in Position 11 Bit1.2 booleanCRT
116Status_ Louver Pos 2 [DPT_1.002]1-Louver in Position 21 Bit1.2 booleanCRT
117Status_ Louver Pos 3 [DPT_1.002]1-Louver in Position 31 Bit1.2 booleanCRT
118Status_ Louver Pos 4 [DPT_1.002]1-Louver in Position 41 Bit1.2 booleanCRT
119Status_ Louver Pos 5 [DPT_1.002]1-Louver in Position 51 Bit1.2 booleanCRT
120Status_ Louver Swing [DPT_1.002]1-Louver Swing1 Bit1.2 booleanCRT
121Status_ Louver Text [DPT_16.001]ASCII String14 Bytes16.0 Character String (ASCII)CRT
122Status_ Louver 4-way-1 / 5 Pos [DPT_5.001]20%, 40%, 60%, 80% and 100%1 Byte5.1 percentage (0..100%)CRT
123Status_ Louver 4-way-1 / 5 Pos [DPT_5.010]Position values: 1,2,3,4,51 Byte5.10 counter pulses (0..255)CRT
124Status_ Louver 4-way-1 Stop [DPT_1.002]1-Louver Stop1 Bit1.2 booleanCRT
125Status_ Louver 4-way-1 Swing [DPT_1.002]1-Louver Swing1 Bit1.2 booleanCRT
126Status_ Louver 4-way-1 Text [DPT_16.001]ASCII String14 Bytes16.0 Character String (ASCII)CRT
127Status_ Louver 4-way-2 / 5 Pos [DPT_5.001]20%, 40%, 60%, 80% and 100%1 Byte5.1 percentage (0..100%)CRT
128Status_ Louver 4-way-2 / 5 Pos [DPT_5.010]Position values: 1,2,3,4,51 Byte5.10 counter pulses (0..255)CRT
129Status_ Louver 4-way-2 Stop [DPT_1.002]1-Louver Stop1 Bit1.2 booleanCRT
130Status_ Louver 4-way-2 Swing [DPT_1.002]1-Louver Swing1 Bit1.2 booleanCRT
131Status_ Louver 4-way-2 Text [DPT_16.001]ASCII String14 Bytes16.0 Character String (ASCII)CRT
132Status_ Louver 4-way-3 / 5 Pos [DPT_5.001]20%, 40%, 60%, 80% and 100%1 Byte5.1 percentage (0..100%)CRT
133Status_ Louver 4-way-3 / 5 Pos [DPT_5.010]Position values: 1,2,3,4,51 Byte5.10 counter pulses (0..255)CRT
134Status_ Louver 4-way-3 Stop [DPT_1.002]1-Louver Stop1 Bit1.2 booleanCRT
135Status_ Louver 4-way-3 Swing [DPT_1.002]1-Louver Swing1 Bit1.2 booleanCRT
136Status_ Louver 4-way-3 Text [DPT_16.001]ASCII String14 Bytes16.0 Character String (ASCII)CRT
137Status_ Louver 4-way-4 / 5 Pos [DPT_5.001]20%, 40%, 60%, 80% and 100%1 Byte5.1 percentage (0..100%)CRT
138Status_ Louver 4-way-4 / 5 Pos [DPT_5.010]Position values: 1,2,3,4,51 Byte5.10 counter pulses (0..255)CRT
139Status_ Louver 4-way-4 Stop [DPT_1.002]1-Louver Stop1 Bit1.2 booleanCRT
140Status_ Louver 4-way-4 Swing [DPT_1.002]1-Louver Swing1 Bit1.2 booleanCRT
141Status_ Louver 4-way-4 Text [DPT_16.001]ASCII String14 Bytes16.0 Character String (ASCII)CRT
142Status_ Temperature Setting [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
143Status_ AutoCool Temperature Setting [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
144Status_ AutoHeat Temperature Setting [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
145Status_ TA [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
146Status_ Control Temperature [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
147Status_ Permit/Prohibit control of Remote Controller ALL [DPT_1.002]0-Permited; 1-Prohibited1 Bit1.2 booleanCRT
148Status_ Permit/Prohibit control of Remote Controller On/Off [1.002]0-Permited; 1-Prohibited1 Bit1.2 booleanCRT
149Status_ Permit/Prohibit control of Remote Controller Mode [1.002]0-Permited; 1-Prohibited1 Bit1.2 booleanCRT
150Status_ Permit/Prohibit control of Remote Controller Temperature Setting [1.002]0-Permited; 1-Prohibited1 Bit1.2 booleanCRT
151Status_ Permit/Prohibit control of Remote Controller FAN speed [1.002]0-Permited; 1-Prohibited1 Bit1.2 booleanCRT
152Status_ Permit/Prohibit control of Remote Controller Louver [1.002]0-Permited; 1-Prohibited1 Bit1.2 booleanCRT
153Status_ Filter Sign Status [DPT_1.005]0-No alarm;1-Alarm1 Bit1.5 alarmCRT
154Status_ Alarm [DPT_1.005]0-No alarm;1-Alarm1 Bit1.5 alarmCRT
155Status_ Alarm Code [2byte]0-No alarm /Any other see man.2 BytesDPT.8CRT
156Status_ Alarm Text [DPT_16.001]ASCII String14 Bytes16.0 Character String (ASCII)CRT
157Status_ Alarm Address Interface [DPT_1.001]0-Off; 1-On1 Bit1.1 switchCRT
158Status_ Alarm Address RC [DPT_1.001]0-Off; 1-On1 Bit1.1 switchCRT
159Status_ Alarm Address IU's [DPT_1.001]0-Off; 1-On1 Bit1.1 switchCRT
160Status_ Save Operation Normal Operation [DPT_1.002]1-No save is active1 Bit1.2 booleanCRT
161Status_ Save Operation 100-50% Operation [DPT_1.002]1-1..49% save is active1 Bit1.2 booleanCRT
162Status_ Save Operation 50% Operation [DPT_1.002]1-50% save is active1 Bit1.2 booleanCRT
163Status_ Save Operation Thermo Off [DPT_1.002]1-100% save is active1 Bit1.2 booleanCRT
164Status_ Ventilation On/Off [DPT_1.001]0-Off; 1-On1 Bit1.1 switchCRT
165Status_ Ventilation Mode Heat Exchange [DPT_1.002]1-Ventilation Heat Exchange Mode is active1 Bit1.2 booleanCRT
166Status_ Ventilation Mode Bypass [DPT_1.002]1-Activate Ventilation Bypass Mode1 Bit1.2 booleanCRT
167Status_ Ventilation Mode Automatic [DPT_1.002]1-Activate Ventilation Automatic Mode1 Bit1.2 booleanCRT
168Status_ Ventilation Air Volume Stop [DPT_1.002]1-Ventilation air volume stop is active1 Bit1.2 booleanCRT
169Status_ Ventilation Air Volume H [DPT_1.002]1-Ventilation air volume H is active1 Bit1.2 booleanCRT
170Status_ Ventilation Air Volume L [DPT_1.002]1-Ventilation air volume L is active1 Bit1.2 booleanCRT
171Status_ Ventilation Air Volume Imbalance [DPT_1.002]1-Ventilation air volume imbalance is active1 Bit1.2 booleanCRT
172Status_ TF [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
173Status_ Soft Cooling [DPT_1.001]0-Off; 1-On1 Bit1.1 switchCRT
174Status_ Operation Standby [DPT_1.001]0-Off; 1-On1 Bit1.1 switchCRT
175Status_ Heating Standby [DPT_1.001]0-Off; 1-On1 Bit1.1 switchCRT
176Status_ Frost Protection Setting [DPT_1.003]0-Disable; 1-Enable1 Bit1.3 enableCRT
177Status_ Night Low Noise [DPT_1.001]0-Off; 1-On1 Bit1.1 switchCRT
178Status_ Cleaning [DPT_1.001]0-Off; 1-On1 Bit1.1 switchCRT
179Status_ Heat Exchanger Clean Operation [DPT_1.001]0-Off; 1-On1 Bit1.1 switchCRT
180Status_ Frost Protection [DPT_1.001]0-Off; 1-On1 Bit1.1 switchCRT
181Status_ Refrigerant Leakage [DPT_1.001]0-Off; 1-On1 Bit1.1 switchCRT
182Status_ Energy Saving Operation [DPT_1.001]0-Off; 1-On1 Bit1.1 switchCRT
183Status_ Demand Response [DPT_5.001]0-100%1 Byte5.1 percentage (0..100%)CRT
184Status_ Multi Tenant Control [DPT_1.001]0-Off; 1-On1 Bit1.1 switchCRT
185Status_ Night Purge [DPT_1.001]0-Off; 1-On1 Bit1.1 switchCRT
186Status_ 24 Hours Operation [DPT_1.001]0-Off; 1-On1 Bit1.1 switchCRT
187Status_ Ventilation Standby [DPT_1.001]0-Off; 1-On1 Bit1.1 switchCRT
188Status_ Central Controll Address [DPT_5.010]0-2551 Byte5.10 counter pulses (0..255)CRT
189Status_ Cooling Temp Upper Limit [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
190Status_ Cooling Temp Lower Limit [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
191Status_ Heating Temp Upper Limit [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
192Status_ Heating Temp Lower Limit [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
193Status_ Dry Temp Upper Limit [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
194Status_ Dry Temp Lower Limit [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
195Status_ AutoTemp Upper Limit [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
196Status_ AutoTemp Lower Limit [DPT_9.001]ºC2 Bytes9.1 temperature (°C)CRT
197Status_ Setting Permit Mode-Fan [DPT_1.003]0-Disable; 1-Enable1 Bit1.3 enableCRT
198Status_ Setting Permit Mode-Cooling [DPT_1.003]0-Disable; 1-Enable1 Bit1.3 enableCRT
199Status_ Setting Permit Mode-Dry [DPT_1.003]0-Disable; 1-Enable1 Bit1.3 enableCRT
200Status_ Setting Permit Mode-Heating [DPT_1.003]0-Disable; 1-Enable1 Bit1.3 enableCRT
201Status_ Setting Permit Mode-Auto [DPT_1.003]0-Disable; 1-Enable1 Bit1.3 enableCRT
202Status_ Setting Fan Auto [DPT_1.003]0-Disable; 1-Enable1 Bit1.3 enableCRT
203Status_ Setting Fan LL [DPT_1.003]0-Disable; 1-Enable1 Bit1.3 enableCRT
204Status_ Setting Fan Speed Range [DPT_5.010]Num of Fan Speeds1 Byte5.10 counter pulses (0..255)CRT
205Status_ Setting Louver [DPT_1.003]0-Disable; 1-Enable1 Bit1.3 enableCRT
206Status_ Setting Louver Num Ways [DPT_5.010]0-No ways. 1-1 way, 2-2 ways, 4-4 ways1 Byte5.10 counter pulses (0..255)CRT
207Status_ Setting Ventilation [DPT_1.003]0-Disable; 1-Enable1 Bit1.3 enableCRT
208Status_ Setting Ventilation Heat Exchange Mode [DPT_1.003]0-Disable; 1-Enable1 Bit1.3 enableCRT
209Status_ Setting Ventilation Bypass Mode [DPT_1.003]0-Disable; 1-Enable1 Bit1.3 enableCRT
210Status_ Setting Ventilation Automatic Mode [DPT_1.003]0-Disable; 1-Enable1 Bit1.3 enableCRT
211Status_ Setting Ventilation Fan Speed Low [DPT_1.003]0-Disable; 1-Enable1 Bit1.3 enableCRT
212Status_ Setting Ventilation Fan Speed High [DPT_1.003]0-Disable; 1-Enable1 Bit1.3 enableCRT
213Status_ Setting Ventilation Fan Speed Unbalance [DPT_1.003]0-Disable; 1-Enable1 Bit1.3 enableCRT
214Status_ Setting Dual Setpoint Function [DPT_1.003]0-Disable; 1-Enable1 Bit1.3 enableCRT
215Status_ Setting Soft Cooling Function [DPT_1.003]0-Disable; 1-Enable1 Bit1.3 enableCRT
216Status_ Setting Fan 5 Speed Function [DPT_1.003]0-Disable; 1-Enable1 Bit1.3 enableCRT
217Status_ Setting Save Function [DPT_1.003]0-Disable; 1-Enable1 Bit1.3 enableCRT
Parameters (120)
ParameterTypeDefault
Download latest database entry for this product and its User Manual from:texthttp://www.toshiba-carrier.co.jp/global/
Send READs for objects on bus recovery (T & U flags must be active)listYes
Delay before sending READsunsignedInt 0…3010
This interface is header of the buslistNo
Disallow control from remote controller on initializationlistNo
Enable "Permit/Prohibit Remote Controller" objectslistNo
Enable system configuration objects (status)listNo
Enable use of objects for Filter (for Control and Status)listNo
Enable object "Alarm Code [2byte]"listNo
Enable object "Alarm Text [14byte]"listNo
Indoor unit has mode AUTO (see docum. for your indoor unit)listYes
Indoor unit has mode HEAT (see docum. for your indoor unit)listYes
Indoor unit has mode COOL (see docum. for your indoor unit)listYes
Indoor unit has mode FAN (see docum. for your indoor unit)listYes
Indoor unit has mode DRY (see docum. for your indoor unit)listYes
Enable "Mode Cool/Heat" objects (for Control and Status)listNo
Enable PID-Compat. Scaling Mode objects (for Control)listNo
Enable use of +/- object for ModelistNo
> DPT type for +/- Mode Objectlist0-Decrease / 1-Increase [DPT_1.007]
Enable use of bit-type Mode objects (for Control)listNo
Enable use of bit-type Mode objects (for Status)listNo
Enable use of Text object for ModelistNo
ASCII strings shown in comm object "Status_ Mode Text"text<<14-byte string values >>
... when mode is AUTOtextmode AUTO
... when mode is HEATtextmode HEAT
... when mode is COOLtextmode COOL
... when mode is FANtextmode FAN
... when mode is DRYtextmode DRY
Num. of FanSpeeds AvailableunsignedInt 1…55
Indoor unit has AUTO fan speed (see docum. for your indoor unit)listYes
DPT object type for fan speedlistScaling [DPT_5.001]
Enable use of +/- object for Fan SpeedlistNo
> DPT type for +/- Fan Speed objectlist0-Decrease / 1-Increase [DPT_1.007]
> Does +/- sequence include fan speed AUTO?listYes
> Rollover Speed at upper/lower limit (when controlling with +/- obj)listNo
Enable "Fan Speed Man/Auto" objects (for Control and Status)listYes
Enable use of bit-type Fan Speed objects (for Control)listYes
Enable use of bit-type Fan Speed objects (for Status)listYes
Enable use of Text object for Fan SpeedlistNo
ASCII strings shown in comm object "Status_ FanSpeed Text"text<<14-byte string values >>
... when fan is AUTOtextfan AUTO
... when fan is STOPtextfan STOP
... when fan is LLtextfan EXTRA LOW
... when fan is SPEED 1textfan SPEED 1
... when fan is SPEED 2textfan SPEED 2
... when fan is SPEED 3textfan SPEED 3
... when fan is SPEED 4textfan SPEED 4
... when fan is SPEED 5textfan SPEED 5
Indoor unit has Louver (see docum. for your indoor unit)listYes
Indoor unit has Louver Positions (see docum. for your indoor unit)listYes
Available positions in Indoor Unit (see docum. for your indoor unit)unsignedInt 5…55
DPT object type for LouverlistScaling [DPT_5.001]
Enable use of bit-type Louver objects (for Control)listNo
Enable use of bit-type Louver objects (for Status)listNo
Enable use of +/- object for LouverlistNo
> DPT type for +/- Louver objectlist0-Decrease / 1-Increase [DPT_1.007]
> Does +/- sequence include STOP Louver?listYes
> Does +/- sequence include SWING Louver?listYes
> Rollover Louver at upper/lower limit (when controlling with +/- obj)listYes
Enable "Louver Swing" objects (for Control and Status)listYes
Enable use of Text object for LouverlistNo
ASCII strings shown in comm object "Status_ Louver Text"text<<14-byte string values >>
... when louver is STOPtextlouver STOP
... when louver is SWINGtextlouver SWING
... when louver is POSITION 1textlouver POS 1
... when louver is POSITION 2textlouver POS 2
... when louver is POSITION 3textlouver POS 3
... when louver is POSITION 4textlouver POS 4
... when louver is POSITION 5textlouver POS 5
Periodic sending of "Status_ Temperature Setting" (in seconds;0=No periodic sending)unsignedInt 0…2550
Transmission of "Status_ Control Temperature"listOnly on change
> "Status_ Control Temperature" periodic sending time (in sec)unsignedInt 1…255180
Transmission of "Status_ TA"listOnly on change
> "Status_ TA" periodic sending time (in sec)unsignedInt 1…255180
Enable use of +/- objs for Temperature SettinglistNo
> DPT type for +/- Temperature Setting objectslist0-Decrease / 1-Increase [DPT_1.007]
Enable limits on Temperature Setting (applies only to Heat and Cool modes)listNo
> Lower limit (ºC)list16.0 ºC
> Upper limit (ºC)list30.0 ºC
Ambient temp. ref. is provided from KNX (carefully read User Guide if enabled)listNo
Enable use of Soft Cooling ObjectslistNo
Enable use of Save Operation ObjectslistNo
Enable use of Ventilation ObjectslistNo
> Enable use of +/- objects for VentilationlistNo
> DPT type for +/- Ventilation objectslist0-Decrease / 1-Increase [DPT_1.007]
show non parameter dependent objectslistYes
hideResidual ObjectslistYes
... when louver 4-way-1 is POSITION 5textlouver POS 5
... when louver 4-way-1 is POSITION 4textlouver POS 4
... when louver 4-way-1 is POSITION 3textlouver POS 3
... when louver 4-way-1 is POSITION 2textlouver POS 2
... when louver 4-way-1 is POSITION 1textlouver POS 1
... when louver 4-way-1 is SWINGtextlouver SWING
... when louver 4-way-1 is STOPtextlouver STOP
... when louver 4-way-2 is STOPtextlouver STOP
... when louver 4-way-2 is SWINGtextlouver SWING
... when louver 4-way-2 is POSITION 1textlouver POS 1
... when louver 4-way-2 is POSITION 2textlouver POS 2
... when louver 4-way-2 is POSITION 3textlouver POS 3
... when louver 4-way-2 is POSITION 4textlouver POS 4
... when louver 4-way-2 is POSITION 5textlouver POS 5
... when louver 4-way-3 is STOPtextlouver STOP
... when louver 4-way-3 is SWINGtextlouver SWING
... when louver 4-way-3 is POSITION 1textlouver POS 1
... when louver 4-way-3 is POSITION 2textlouver POS 2
... when louver 4-way-3 is POSITION 3textlouver POS 3
... when louver 4-way-3 is POSITION 4textlouver POS 4
... when louver 4-way-3 is POSITION 5textlouver POS 5
... when louver 4-way-4 is STOPtextlouver STOP
... when louver 4-way-4 is SWINGtextlouver SWING
... when louver 4-way-4 is POSITION 1textlouver POS 1
... when louver 4-way-4 is POSITION 2textlouver POS 2
... when louver 4-way-4 is POSITION 3textlouver POS 3
... when louver 4-way-4 is POSITION 4textlouver POS 4
... when louver 4-way-4 is POSITION 5textlouver POS 5
Num. Of Ways in Indoor Unit (see docum. for your indoor unit)list1 way
Enable use of DPT_5001 for Fan SpeedlistYes
Enable use of DPT_5010 for Fan SpeedlistYes
Enable use of DPT_5001 for LouverlistYes
Enable use of DPT_5010 for LouverlistYes

Version history

ApplicationApp noFingerprintFirst seenSizeFile
BMS-IFKX0TLR-E V10 1.0 latest$00282B342026-11-25115 KBDownload

About this file

This is the official ETS product database for the Intesis KNX Interface for Toshiba AC (BMS-IFKX0TLR-E), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Intesis

All Intesis products