Ekinex S.p.A. EK-EP2-TP Room temperature controller with LCD

Room temperature controller with LCD EK-EP2-TP

Ekinex S.p.A. · Order number EK-EP2-TP · Heating, cooling and ventilation

Room temperature controller with LCD

Download .knxprod APEKEP2TP 0.4 · 157 KB

Product

ManufacturerEkinex S.p.A.
Product nameRoom temperature controller with LCD
Order numberEK-EP2-TP
HardwareRoom temperature controller with LCD
MediumTwisted Pair
Bus current (mA)12
Rail mountedNo
RegistrationCertified · 2015-01-14
Languagesen-US, de-DE, fr-FR, it-IT
Catalog entryM-00B6_H-000020-1_HP-4550-04-B890_CI-EK.2DEP2.2DTP-2
FingerprintB890
SHA-256f0b26f8e57893e9e89b72409b06096d6f6aa7eefd831313c78cd6196f46558b9
First seen2026-11-25
Markets69 markets

Application program: APEKEP2TP 0.4

Application number$4550
Version0.4
Mask versionMV-0705 (7.5)
KNX Data SecureNo
Minimum ETS version4.0
Parameters474
Group objects142
Group objects (142)
NoNameFunctionSizeDPTFlags
0Technical alarm1 Bit1.5 alarmCW
1Brightness value2 Bytes9.4 lux (Lux)CRT
2Leds intensity percentage1 Byte5.1 percentage (0..100%)CW
3Temperature value2 Bytes9.1 temperature (°C)CRT
4Light threshold 1 - Switch1 Bit1.1 switchCRT
5Light threshold 2 - Switch1 Bit1.1 switchCRT
6Rocker 1 - Led first color A1 Bit1.1 switchCRWTU
7Rocker 1 - Led second color A1 Bit1.1 switchCRWTU
8Rocker 1 - Led first color B1 Bit1.1 switchCRWTU
9Rocker 1 - Led second color B1 Bit1.1 switchCRWTU
10Rocker 2 - Led first color A1 Bit1.1 switchCRWTU
11Rocker 2 - Led second color A1 Bit1.1 switchCRWTU
12Rocker 2 - Led first color B1 Bit1.1 switchCRWTU
13Rocker 2 - Led second color B1 Bit1.1 switchCRWTU
16Temperature threshold 1 - Switch1 Bit1.1 switchCRT
17Temperature threshold 2 - Switch1 Bit1.1 switchCRT
20Temperature value sensor (from input 1)2 Bytes9.1 temperature (°C)CRT
20Coil battery temperature sensor (from input 1)2 Bytes9.1 temperature (°C)CRT
20Room temperature sensor (from input 1)2 Bytes9.1 temperature (°C)CRT
20Antistratification temperature sensor (from input 1)2 Bytes9.1 temperature (°C)CRT
20Floor surface temperature sensor (from input 1)2 Bytes9.1 temperature (°C)CRT
20Outdoor temperature sensor (from input 1)2 Bytes9.1 temperature (°C)CRT
21Temperature threshold 1 sensor 1 - Switch1 Bit1.1 switchCRT
22Temperature threshold 2 sensor 1 - Switch1 Bit1.1 switchCRT
23Temperature value sensor (from input 2)2 Bytes9.1 temperature (°C)CRT
23Coil battery temperature sensor (from input 2)2 Bytes9.1 temperature (°C)CRT
23Room temperature sensor (from input 2)2 Bytes9.1 temperature (°C)CRT
23Antistratification temperature sensor (from input 2)2 Bytes9.1 temperature (°C)CRT
23Floor surface temperature sensor (from input 2)2 Bytes9.1 temperature (°C)CRT
23Outdoor temperature sensor (from input 2)2 Bytes9.1 temperature (°C)CRT
24Temperature threshold 1 sensor 2 - Switch1 Bit1.1 switchCRT
25Temperature threshold 2 sensor 2 - Switch1 Bit1.1 switchCRT
26Window contact sensor (from input 1)1 Bit1.19 window/doorCRT
27Window contact sensor (from input 2)1 Bit1.19 window/doorCRT
28Anticondensation sensor (from input 1)1 Bit1.5 alarmCRT
29Anticondensation sensor (from input 2)1 Bit1.5 alarmCRT
30Card holder contact sensor (from input 1)1 Bit1.18 occupancyCRT
31Card holder contact sensor (from input 2)1 Bit1.18 occupancyCRT
32Presence sensor 1 (from bus)1 Bit1.18 occupancyCW
33Presence sensor 2 (from bus)1 Bit1.18 occupancyCW
34Room temperature (from bus)2 Bytes9.1 temperature (°C)CW
37Antistratification temperature (from bus)2 Bytes9.1 temperature (°C)CW
38Outdoor temperature (from bus)2 Bytes9.1 temperature (°C)CW
40Coil temperature (from bus)2 Bytes9.1 temperature (°C)CW
41Floor temperature (from bus)2 Bytes9.1 temperature (°C)CW
43Windows contact sensor 1 (from bus)1 Bit1.19 window/doorCW
44Windows contact sensor 2 (from bus)1 Bit1.19 window/doorCW
45Contact of card holder (from bus)1 Bit1.18 occupancyCW
46Anticondensation (from bus)1 Bit1.1 switchCW
47Weighted temperature2 Bytes9.1 temperature (°C)CRT
48Heating/cooling status out1 Bit1.100 heating/coolingCRT
49Heating/cooling status in1 Bit1.100 heating/coolingCW
50HVAC mode in1 Byte20.102 HVAC modeCW
51HVAC forced mode in1 Byte20.102 HVAC modeCW
52Actual setpoint2 Bytes9.1 temperature (°C)CRT
53HVAC manual mode1 Byte20.102 HVAC modeCWTU
54Chrono active status1 Bit1.11 stateCRT
55Manual setpoint2 Bytes9.1 temperature (°C)CW
56Manual/forced setpoint active status1 Bit1.11 stateCRWTU
57Comfort setpoint (heating)2 Bytes9.1 temperature (°C)CRWTU
58Comfort setpoint (cooling)2 Bytes9.1 temperature (°C)CRWTU
59Standby setpoint (heating)2 Bytes9.1 temperature (°C)CRWTU
60Standby setpoint (cooling)2 Bytes9.1 temperature (°C)CRWTU
61Economy setpoint (heating)2 Bytes9.1 temperature (°C)CRWTU
62Economy setpoint (cooling)2 Bytes9.1 temperature (°C)CRWTU
63Building protection setpoint (heating)2 Bytes9.1 temperature (°C)CRWTU
64Building protection setpoint (cooling)2 Bytes9.1 temperature (°C)CRWTU
65Heating out command1 Byte5.1 percentage (0..100%)CRT
65Heating out command1 Bit1.1 switchCRT
65Heating and cooling out command1 Bit1.1 switchCRT
65Heating and cooling out command1 Byte5.1 percentage (0..100%)CRT
66Cooling out command1 Byte5.1 percentage (0..100%)CRT
66Cooling out command1 Bit1.1 switchCRT
67Auxiliary heating output command1 Bit1.1 switchCRT
67Auxiliary heating and cooling output command1 Bit1.1 switchCRT
68Auxiliary cooling output command1 Bit1.1 switchCRT
69Auxiliary heating enable1 Bit1.3 enableCW
70Auxiliary cooling enable1 Bit1.3 enableCW
71Fan continuous speed1 Byte5.1 percentage (0..100%)CRT
72Fan speed 11 Bit1.1 switchCRT
73Fan speed 21 Bit1.1 switchCRT
74Fan speed 31 Bit1.1 switchCRT
75Fan control disable1 Bit1.2 booleanCW
76Fan manual speed1 Byte5.10 counter pulses (0..255)CRWU
77Fan speed1 Byte5.10 counter pulses (0..255)CRT
78Fan manual active status1 Bit1.11 stateCRWT
79HVAC scene number1 Byte17.1 scene numberCW
83HVAC mode out1 Byte20.102 HVAC modeCRT
90Temperature setpoint change lock1 Bit1.3 enableCW
91Manual mode lock1 Bit1.3 enableCW
92Anticondensation alarm1 Bit1.5 alarmCRT
93Rockers lock1 Bit1.2 booleanCW
94Thermal generator lock1 Bit1.5 alarmCW
95Alarm 1 (from bus)1 Bit1.5 alarmCW
96Alarm 2 (from bus)1 Bit1.5 alarmCW
97Alarm 3 (from bus)1 Bit1.5 alarmCW
98Alarm 4 (from bus)1 Bit1.5 alarmCW
99Dehumidification Setpoint2 Bytes9.7 humidity (%)CRWTU
100Humidification Setpoint2 Bytes9.7 humidity (%)CRWTU
101Building protection HVAC mode active1 Bit1.11 stateCRT
102Fan manual speed percentage1 Byte5.1 percentage (0..100%)CRT
103Fan manual speed off status1 Bit1.11 stateCRT
104Logic function 1 - Input 11 Bit1.1 switchCWTU
105Logic function 1 - Input 21 Bit1.1 switchCWTU
106Logic function 1 - Input 31 Bit1.1 switchCWTU
107Logic function 1 - Input 41 Bit1.1 switchCWTU
108Logic function 1 - Output1 Bit1.1 switchCRT
109Logic function 2 - Input 11 Bit1.1 switchCWTU
110Logic function 2 - Input 21 Bit1.1 switchCWTU
111Logic function 2 - Input 31 Bit1.1 switchCWTU
112Logic function 2 - Input 41 Bit1.1 switchCWTU
113Logic function 2 - Output1 Bit1.1 switchCRT
114Logic function 3 - Input 11 Bit1.1 switchCWTU
115Logic function 3 - Input 21 Bit1.1 switchCWTU
116Logic function 3 - Input 31 Bit1.1 switchCWTU
117Logic function 3 - Input 41 Bit1.1 switchCWTU
118Logic function 3 - Output1 Bit1.1 switchCRT
119Logic function 4 - Input 11 Bit1.1 switchCWTU
120Logic function 4 - Input 21 Bit1.1 switchCWTU
121Logic function 4 - Input 31 Bit1.1 switchCWTU
122Logic function 4 - Input 41 Bit1.1 switchCWTU
123Logic function 4 - Output1 Bit1.1 switchCRT
124Logic function 5 - Input 11 Bit1.1 switchCWTU
125Logic function 5 - Input 21 Bit1.1 switchCWTU
126Logic function 5 - Input 31 Bit1.1 switchCWTU
127Logic function 5 - Input 41 Bit1.1 switchCWTU
128Logic function 5 - Output1 Bit1.1 switchCRT
129Logic function 6 - Input 11 Bit1.1 switchCWTU
130Logic function 6 - Input 21 Bit1.1 switchCWTU
131Logic function 6 - Input 31 Bit1.1 switchCWTU
132Logic function 6 - Input 41 Bit1.1 switchCWTU
133Logic function 6 - Output1 Bit1.1 switchCRT
134Logic function 7 - Input 11 Bit1.1 switchCWTU
135Logic function 7 - Input 21 Bit1.1 switchCWTU
136Logic function 7 - Input 31 Bit1.1 switchCWTU
137Logic function 7 - Input 41 Bit1.1 switchCWTU
138Logic function 7 - Output1 Bit1.1 switchCRT
139Logic function 8 - Input 11 Bit1.1 switchCWTU
140Logic function 8 - Input 21 Bit1.1 switchCWTU
141Logic function 8 - Input 31 Bit1.1 switchCWTU
142Logic function 8 - Input 41 Bit1.1 switchCWTU
143Logic function 8 - Output1 Bit1.1 switchCRT
Parameters (204)
ParameterTypeDefault
Light sensorlistdisabled
Temperature sensorlistenabled
Input 1listdisabled
Led intensity correlationlistnone
Minimum change of value to send [Lux]float 0…67076050
Cyclic sending intervallistno sending
Minimum change of value to send [K]float 0…50.5
Delay after bus voltage recoverytime400
Leds intensity from buslistno
Leds intensitylist50%
Led first color 1Alistwhen contact closed
Blinkinglistno
Signal from buslistnot inverted
Alwayslistoff
Off delaytime20
Blinking period / typelist1 s on, 1 s off
Led second color 1Alistwhen contact closed
Led second color 1Blistwhen contact closed
Led first color 1Blistwhen contact closed
Led first color 2Alistwhen contact closed
Led second color 2Alistwhen contact closed
Led first color 2Blistwhen contact closed
Led second color 2Blistwhen contact closed
Value [Lux]float 0…670760500
Hysteresislist50 lux
Threshold 1listnot active
Threshold 2listnot active
Sensor value multiplier (1 ÷ 255) x 0.1unsignedInt 1…25510
Temperature offsetlist0.0 °C
Technical alarmlistdisabled
Input 2listdisabled
Contact typelistNO (normally open)
Relative humidity sensorlistdisabled
Value [°C]float 0…5045
Value [°C]float 0…507
Hysteresislist0.4 K
Value [%]unsignedInt 0…10065
Hysteresis [%]list3.0%
Minimum change of value to send [%]unsignedInt 0…102
Temperature displayed unitlistCelsius
Default displayed informationlistactual temperature
Time to return to default displaylist5 s
Button function levellistsystem integrator
Time to exit change without savinglist10 s
Debounce timetime20
Digital sensors timeouttime300
Room temperaturelistdisabled
Relative humiditylistdisabled
Antistratification temperaturelistdisabled
Outdoor temperaturelistdisabled
Air qualitylistdisabled
Coil temperaturelistdisabled
Floor surface temperaturelistdisabled
Flow temperaturelistdisabled
Window contact 1listdisabled
Window contact 2listdisabled
Presence sensor 1listdisabled
Presence sensor 2listdisabled
Card holder contactlistdisabled
Humidity CO dimensionlist2 bytes
Main source for temperature valuelistinternal sensor
Additional source temperature valuelistinternal sensor
Relative weightlist50% / 50%
Filter typelistmedium
Main source for temperature valuelistinput
Additional source temperature valuelistinput
Additional source temperature valuelistfrom bus
Thermostat functionlistheating
Anticondensationlistdisabled
Heating - cooling switch overlistfrom bus
Heating - cooling cyclic sending intervallistno sending
Max manual temperature changelist±3 °C
Max setpoint temperature changelist±9 °C
Setpoint cyclic sending intervallistno sending
Sceneslistdisabled
Comfort temp. setpoint [°C]float 10…5021
Standby temperature setpoint [°C]float 10…5018
Economy temp. setpoint [°C]float 10…5016
Building protection temp. setpoint [°C]float 2…107
Control typelist2 points hysteresis
Command Communication Objectlistseparated
Hysteresislist0.3 K
PWM cycle timetime15
Proportional band [0.1K]unsignedInt 5…10040
Integral time [min]unsignedInt 0…25590
Valve protection functionlistdisabled
Frequencylistonce a week
Time intervallist10 s
Floor temperature limitationlistdisabled
Temperature limit [°C]float 20…4029
Auxiliary heatinglistdisabled
Communication objectlistseparated
Offset from setpointlist0.6 K
Disabled from buslistno
Ventilation for auxiliary heatinglistdisabled
Comfort temp. setpoint [°C]float 10…5023
Standby temperature setpoint [°C]float 10…5026
Economy temp. setpoint [°C]float 10…5028
Building protection temp. setpoint [°C]float 30…5036
Cooling typelistfancoils
Auxiliary coolinglistdisabled
Anticondensation with probelistdisabled
Active anticondensationlistdisabled
Min. change of value to send [%]unsignedInt 0…10010
Anticondensation hysteresis rangelist0.5 K
Control typelist1 speed
Threshold first speed [0.1K]unsignedInt 0…2550
Threshold second speed [0.1K]unsignedInt 0…25510
Threshold third speed [0.1K]unsignedInt 0…25520
Manual operationlistnot depending on the temperature
Hot startlistno
Use coil battery temperature sensor for dehumidificationlistno
Speed control hysteresislist0.3 K
Speed proportional band [0.1K]unsignedInt 5…10030
Min. change of value to send [%]unsignedInt 2…4010
Min. temp. to start ventilation [°C]unsignedInt 28…4028
Min. temp. to start dehumidif. [°C]unsignedInt 0…25510
Relative humidity setpoint [%]unsignedInt 0…10065
Relative humidity setpoint [%]list0.6%
Max. temp. diff. to disable dehum. [°C]float 0…500.5
Forced speedlist1 speed
Forced speedunsignedInt 0…10020
Antistratification functionlistdisabled
Antistratification temp. differentiallist2.00 [K/m]
Hysteresislist0.5 K
Disable ventilation from buslistno
Fan start delaylist0 s
Fan stop delaylist0 s
Download overwritelistdisabled
Scene 1listdisabled
Scene 2listdisabled
Scene 3listdisabled
Scene 4listdisabled
Scene 5listdisabled
Scene 6listdisabled
Scene 7listdisabled
Scene 8listdisabled
Learning modelistdisabled
HVAC modelistcomfort
Scene numberunsignedInt 1…641
Activation delaytime0
Windows contacts functionlistdisabled
Presence sensors functionlistdisabled
Presence sensors uselistcomfort extension
Thermostat modeslistcomfort - standby
Wait time to building protection modetime60
Absence time to switch HVAC modetime60
Signallistnot inverted
Device operation asliststand-alone
Main source for temperature valuelistinput 1
Additional source temperature valuelistinput 1
Additional source temperature valuelistinput 2
Actual temperaturelistalways enabled
Temperature setpointlistenabled
Relative humiditylistenabled
Relative humidity setpointlistenabled
Perceived temperaturelistenabled
Outdoor temperaturelistenabled
Air qualitylistenabled
Card holder functionlistdisabled
On card insertion switch HVAC mode tolistcomfort
On card removal switch HVAC mode toliststandby
Activation delay on card insertiontime0
Activation delay on card removaltime0
Backlight intensitylist50%
Automatic backlight dimminglistdisabled
Energy savinglistdisabled
Visualization typelistfull
Time before energy saving modelist10 s
Backlight when in energy saving modelist25%
Behaviour on button presslistbacklight only
Ventilation for auxiliary coolinglistdisabled
Heating typelistradiators
Heating typelistfancoils
End of manual operationlisttill first telegram from bus
Duration of comfort extensionlistnot allowed
Analog sensors timeouttime300
Flow temperature (project)list14 °C
Min control value [%]unsignedInt 0…3015
Max control value [%]unsignedInt 70…10085
Transmission delay after mode changetime400
Hysteresis positionlistbelow
Hysteresis positionlistabove
Exit manual mode on setpoint from buslistno
Logic functionslistdisabled
Logic functionlistdisabled
Logic operationlistOR
Output cyclic transmission intervallistno sending
Logic object 1listdisabled
Logic object 2listdisabled
Logic object 3listdisabled
Logic object 4listdisabled
Logic object 1 negatedlistno
Logic object 2 negatedlistno
Logic object 3 negatedlistno
Logic object 4 negatedlistno
Logic object 1 read at startuplistno
Logic object 2 read at startuplistno
Logic object 3 read at startuplistno
Logic object 4 read at startuplistno
Logic object 1 default valuelistnone
Logic object 2 default valuelistnone
Logic object 3 default valuelistnone
Logic object 4 default valuelistnone

Version history

ApplicationApp noFingerprintFirst seenSizeFile
APEKEP2TP 0.4 latest$4550B8902026-11-25157 KBDownload
APEKEP2TP 0.3$45505FD42026-11-25157 KBDownload
APEKEP2TP 0.2$455090842026-11-25230 KBDownload
APEKEP2TP 0.1$4550164B2026-11-25230 KBDownload
APEKEP2TP 0.1$4550164B2026-11-25230 KBDownload

About this file

This is the official ETS product database for the Ekinex S.p.A. Room temperature controller with LCD (EK-EP2-TP), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Ekinex S.p.A.

All Ekinex S.p.A. products