Ekinex S.p.A. EK-EM2-TP-F Full room temperature controller with LCD

Full room temperature controller with LCD EK-EM2-TP-F

Ekinex S.p.A. · Order number EK-EM2-TP-F · Heating, cooling and ventilation

Full room temperature controller with LCD

Download .knxprod APPEKEM2TP 1.1 · 234 KB

Product

ManufacturerEkinex S.p.A.
Product nameFull room temperature controller with LCD
Order numberEK-EM2-TP-F
HardwareFull room temperature controller with LCD
MediumTwisted Pair
Bus current (mA)13
Rail mountedNo
RegistrationRegistered · 2026-09-15
Languagesen-US, de-DE, fr-FR, it-IT
Catalog entryM-00B6_H-00B600000019-1_HP-454D-11-78B7_CI-EK.2DEM2.2DTP.2DF-1
Fingerprint78B7
SHA-256bde7c0f1aa612be7dc55abbbb09685020c58bf6e306af135a78eb7a8778be16f
First seen2026-11-25
Markets69 markets

Application program: APPEKEM2TP 1.1

Application number$454D
Version1.1
Mask versionMV-0705 (7.5)
KNX Data SecureNo
Minimum ETS version5.0
Parameters573
Group objects178
Group objects (178)
NoNameFunctionSizeDPTFlags
0Technical alarm1 Bit1.5 alarmCW
1Brightness value2 Bytes9.4 lux (Lux)CRT
2Leds intensity percentage1 Byte5.1 percentage (0..100%)CW
3Temperature value2 Bytes9.1 temperature (°C)CRT
4Light threshold 1 - Switch1 Bit1.1 switchCRT
5Light threshold 2 - Switch1 Bit1.1 switchCRT
6Rocker 1 - Led first color A1 Bit1.1 switchCRWTU
7Rocker 1 - Led second color A1 Bit1.1 switchCRWTU
8Rocker 1 - Led first color B1 Bit1.1 switchCRWTU
9Rocker 1 - Led second color B1 Bit1.1 switchCRWTU
10Rocker 2 - Led first color A1 Bit1.1 switchCRWTU
11Rocker 2 - Led second color A1 Bit1.1 switchCRWTU
12Rocker 2 - Led first color B1 Bit1.1 switchCRWTU
13Rocker 2 - Led second color B1 Bit1.1 switchCRWTU
14Humidity value (1 byte)1 Byte5.1 percentage (0..100%)CRT
15Humidity value (2 bytes)2 Bytes9.7 humidity (%)CRT
16Temperature threshold 1 - Switch1 Bit1.1 switchCRT
17Temperature threshold 2 - Switch1 Bit1.1 switchCRT
18Humidity threshold 1 - Switch1 Bit1.1 switchCRT
19Humidity threshold 2 - Switch1 Bit1.1 switchCRT
20Temperature value sensor (from input 1)2 Bytes9.1 temperature (°C)CRT
20Coil battery temperature sensor (from input 1)2 Bytes9.1 temperature (°C)CRT
20Room temperature sensor (from input 1)2 Bytes9.1 temperature (°C)CRT
20Antistratification temperature sensor (from input 1)2 Bytes9.1 temperature (°C)CRT
20Floor surface temperature sensor (from input 1)2 Bytes9.1 temperature (°C)CRT
20Outdoor temperature sensor (from input 1)2 Bytes9.1 temperature (°C)CRT
21Temperature threshold 1 sensor 1 - Switch1 Bit1.1 switchCRT
22Temperature threshold 2 sensor 1 - Switch1 Bit1.1 switchCRT
23Temperature value sensor (from input 2)2 Bytes9.1 temperature (°C)CRT
23Coil battery temperature sensor (from input 2)2 Bytes9.1 temperature (°C)CRT
23Room temperature sensor (from input 2)2 Bytes9.1 temperature (°C)CRT
23Antistratification temperature sensor (from input 2)2 Bytes9.1 temperature (°C)CRT
23Floor surface temperature sensor (from input 2)2 Bytes9.1 temperature (°C)CRT
23Outdoor temperature sensor (from input 2)2 Bytes9.1 temperature (°C)CRT
24Temperature threshold 1 sensor 2 - Switch1 Bit1.1 switchCRT
25Temperature threshold 2 sensor 2 - Switch1 Bit1.1 switchCRT
26Window contact sensor (from input 1)1 Bit1.19 window/doorCRT
27Window contact sensor (from input 2)1 Bit1.19 window/doorCRT
28Anticondensation sensor (from input 1)1 Bit1.5 alarmCRT
29Anticondensation sensor (from input 2)1 Bit1.5 alarmCRT
30Card holder contact sensor (from input 1)1 Bit1.18 occupancyCRT
31Card holder contact sensor (from input 2)1 Bit1.18 occupancyCRT
32Presence sensor 1 (from bus)1 Bit1.18 occupancyCW
33Presence sensor 2 (from bus)1 Bit1.18 occupancyCW
34Room temperature (from bus)2 Bytes9.1 temperature (°C)CW
37Antistratification temperature (from bus)2 Bytes9.1 temperature (°C)CW
38Outdoor temperature (from bus)2 Bytes9.1 temperature (°C)CW
40Coil temperature (from bus)2 Bytes9.1 temperature (°C)CW
41Floor temperature (from bus)2 Bytes9.1 temperature (°C)CW
42Flow temperature (from bus)2 Bytes9.1 temperature (°C)CW
43Windows contact sensor 1 (from bus)1 Bit1.19 window/doorCW
44Windows contact sensor 2 (from bus)1 Bit1.19 window/doorCW
45Contact of card holder (from bus)1 Bit1.18 occupancyCW
46Anticondensation (from bus)1 Bit1.1 switchCW
47Weighted temperature2 Bytes9.1 temperature (°C)CRT
48Heating/cooling status out1 Bit1.100 cooling/heatingCRT
49Heating/cooling status in1 Bit1.100 cooling/heatingCW
50Enable thermostat command1 Bit1.3 enableCRWTU
51Enabled thermostat status1 Bit1.11 stateCRT
52Actual setpoint2 Bytes9.1 temperature (°C)CRT
53Manual setpoint2 Bytes9.1 temperature (°C)CW
54Manual/forced setpoint active status1 Bit1.11 stateCRWTU
55HVAC mode in1 Byte20.102 HVAC modeCW
56HVAC forced mode in1 Byte20.102 HVAC modeCW
57HVAC manual mode1 Byte20.102 HVAC modeCWTU
58HVAC mode out1 Byte20.102 HVAC modeCRT
59Chrono active status1 Bit1.11 stateCRT
60Setpoint (heating)2 Bytes9.1 temperature (°C)CRWTU
60Comfort setpoint (heating)2 Bytes9.1 temperature (°C)CRWTU
61Setpoint (cooling)2 Bytes9.1 temperature (°C)CRWTU
61Comfort setpoint (cooling)2 Bytes9.1 temperature (°C)CRWTU
62Standby setpoint (heating)2 Bytes9.1 temperature (°C)CRWTU
63Standby setpoint (cooling)2 Bytes9.1 temperature (°C)CRWTU
64Economy setpoint (heating)2 Bytes9.1 temperature (°C)CRWTU
65Economy setpoint (cooling)2 Bytes9.1 temperature (°C)CRWTU
66Building protection setpoint (heating)2 Bytes9.1 temperature (°C)CRWTU
67Building protection setpoint (cooling)2 Bytes9.1 temperature (°C)CRWTU
68Heating out command1 Byte5.1 percentage (0..100%)CRT
68Heating out command1 Bit1.1 switchCRT
68Heating and cooling out command1 Bit1.1 switchCRT
68Heating and cooling out command1 Byte5.1 percentage (0..100%)CRT
69Cooling out command1 Byte5.1 percentage (0..100%)CRT
69Cooling out command1 Bit1.1 switchCRT
70Auxiliary heating output command1 Bit1.1 switchCRT
70Auxiliary heating and cooling output command1 Bit1.1 switchCRT
71Auxiliary cooling output command1 Bit1.1 switchCRT
72Disable auxiliary heating1 Bit1.3 enableCW
73Disable auxiliary cooling1 Bit1.3 enableCW
74AC enable in1 Bit1.1 switchCW
75AC enable out1 Bit1.1 switchCRT
76AC setpoint in2 Bytes9.1 temperature (°C)CW
77AC setpoint out2 Bytes9.1 temperature (°C)CRT
78AC HVAC control mode in1 Byte20.105 HVAC control modeCWTU
79AC HVAC control mode out1 Byte20.105 HVAC control modeCRT
80Fan speed 11 Bit1.1 switchCRT
81Fan speed 21 Bit1.1 switchCRT
82Fan speed 31 Bit1.1 switchCRT
83Fan control disable1 Bit1.2 booleanCW
84Fan speed in1 Byte5.100 fan stage (0..255)CW
84Fan speed in1 Byte5.1 percentage (0..100%)CW
85Fan speed out1 Byte5.100 fan stage (0..255)CRT
85Fan speed out1 Byte5.1 percentage (0..100%)CRT
86Fan speed man/auto in1 Bit1.2 booleanCW
87Fan speed man/auto out1 Bit1.2 booleanCRT
88HVAC scene number1 Byte17.1 scene numberCW
88HVAC scene number1 Byte18.1 scene controlCW
89Comfort state1 Bit1.6 binary valueCRT
90Dew-point temperature2 Bytes9.1 temperature (°C)CRT
91Perceived temperature2 Bytes9.1 temperature (°C)CRT
92Dehumidification command1 Bit1.1 switchCRT
93Dehumidification control disable1 Bit1.2 booleanCW
94Dehumidification water battery command1 Bit1.1 switchCRT
95Dehumidification integration control1 Bit1.1 switchCRT
96Humidification command1 Bit1.1 switchCRT
97Humidification control disable1 Bit1.2 booleanCW
98Temperature setpoint change lock1 Bit1.3 enableCW
99Manual mode lock1 Bit1.3 enableCW
100Anticondensation alarm1 Bit1.5 alarmCRT
101Rockers lock1 Bit1.3 enableCW
102Thermal generator lock1 Bit1.5 alarmCW
103Alarm 1 (from bus)1 Bit1.5 alarmCW
104Alarm 2 (from bus)1 Bit1.5 alarmCW
105Alarm 3 (from bus)1 Bit1.5 alarmCW
106Alarm 4 (from bus)1 Bit1.5 alarmCW
107Relative humidity setpoint for dehumidification2 Bytes9.7 humidity (%)CRWTU
108Relative humidity setpoint for humidification2 Bytes9.7 humidity (%)CRWTU
109Building protection HVAC mode active1 Bit1.11 stateCRT
110Fan manual speed percentage1 Byte5.1 percentage (0..100%)CRT
111Fan manual speed off status1 Bit1.11 stateCRT
112Fan continuous speed1 Byte5.1 percentage (0..100%)CRT
113Logic function 1 - Input 11 Bit1.1 switchCWTU
114Logic function 1 - Input 21 Bit1.1 switchCWTU
115Logic function 1 - Input 31 Bit1.1 switchCWTU
116Logic function 1 - Input 41 Bit1.1 switchCWTU
117Logic function 1 - Output1 Bit1.1 switchCRT
118Logic function 2 - Input 11 Bit1.1 switchCWTU
119Logic function 2 - Input 21 Bit1.1 switchCWTU
120Logic function 2 - Input 31 Bit1.1 switchCWTU
121Logic function 2 - Input 41 Bit1.1 switchCWTU
122Logic function 2 - Output1 Bit1.1 switchCRT
123Logic function 3 - Input 11 Bit1.1 switchCWTU
124Logic function 3 - Input 21 Bit1.1 switchCWTU
125Logic function 3 - Input 31 Bit1.1 switchCWTU
126Logic function 3 - Input 41 Bit1.1 switchCWTU
127Logic function 3 - Output1 Bit1.1 switchCRT
128Logic function 4 - Input 11 Bit1.1 switchCWTU
129Logic function 4 - Input 21 Bit1.1 switchCWTU
130Logic function 4 - Input 31 Bit1.1 switchCWTU
131Logic function 4 - Input 41 Bit1.1 switchCWTU
132Logic function 4 - Output1 Bit1.1 switchCRT
133Logic function 5 - Input 11 Bit1.1 switchCWTU
134Logic function 5 - Input 21 Bit1.1 switchCWTU
135Logic function 5 - Input 31 Bit1.1 switchCWTU
136Logic function 5 - Input 41 Bit1.1 switchCWTU
137Logic function 5 - Output1 Bit1.1 switchCRT
138Logic function 6 - Input 11 Bit1.1 switchCWTU
139Logic function 6 - Input 21 Bit1.1 switchCWTU
140Logic function 6 - Input 31 Bit1.1 switchCWTU
141Logic function 6 - Input 41 Bit1.1 switchCWTU
142Logic function 6 - Output1 Bit1.1 switchCRT
143Logic function 7 - Input 11 Bit1.1 switchCWTU
144Logic function 7 - Input 21 Bit1.1 switchCWTU
145Logic function 7 - Input 31 Bit1.1 switchCWTU
146Logic function 7 - Input 41 Bit1.1 switchCWTU
147Logic function 7 - Output1 Bit1.1 switchCRT
148Logic function 8 - Input 11 Bit1.1 switchCWTU
149Logic function 8 - Input 21 Bit1.1 switchCWTU
150Logic function 8 - Input 31 Bit1.1 switchCWTU
151Logic function 8 - Input 41 Bit1.1 switchCWTU
152Logic function 8 - Output1 Bit1.1 switchCRT
153Dummy_12 Bytes9.1 temperature (°C)CRT
154Dummy_22 Bytes9.1 temperature (°C)CRT
155Dummy_32 Bytes9.1 temperature (°C)CRT
156Dummy_42 Bytes9.1 temperature (°C)CRT
157Dummy_52 Bytes9.1 temperature (°C)CRT
158Dummy_62 Bytes9.1 temperature (°C)CRT
159Dummy_72 Bytes9.1 temperature (°C)CRT
160Dummy_82 Bytes9.1 temperature (°C)CRT
Parameters (276)
ParameterTypeDefault
Light sensorlistDisabled
Temperature sensorlistEnabled
Input 1listDisabled
Led intensity correlationlistNone
Minimum change of value to send [Lux]float 0…67076050
Cyclic sending intervallistNo sending
Minimum change of value to send [K]float 0…50.5
Delay after bus voltage recoverytime400
Leds intensity from buslistNo
Leds intensitylist100%
Led first color 1AlistWhen contact closed
BlinkinglistNo
Signal from buslistNot inverted
AlwayslistOff
Off delaytime20
Blinking period / typelist1 s on, 1 s off
Led second color 1AlistWhen contact closed
Led second color 1BlistWhen contact closed
Led first color 1BlistWhen contact closed
Led first color 2AlistWhen contact closed
Led second color 2AlistWhen contact closed
Led first color 2BlistWhen contact closed
Led second color 2BlistWhen contact closed
Value [Lux]float 0…670760500
Hysteresislist50 lux
Threshold 1listNot active
Threshold 2listNot active
Sensor value multiplier (1 ÷ 255) x 0.1unsignedInt 1…25510
Temperature offsetlist0.0 °C
Technical alarmlistDisabled
Input 2listDisabled
Contact typelistNO (normally open)
Relative humidity sensorlistEnabled
Value [°C]float 0…5045
Value [°C]float 0…507
Hysteresislist0.4 K
Value [%]unsignedInt 0…10065
Hysteresis [%]list3.0%
Minimum change of value to send [%]unsignedInt 0…102
Temperature displayed unitlistCelsius
Default displayed informationlistActual temperature
Time to return to default displaylist2 s
Button function levellistSystem integrator
Time to exit change with savinglist3 s
Debounce timetime20
Digital sensors timeouttime300
Room temperaturelistDisabled
Relative humiditylistDisabled
Antistratification temperaturelistDisabled
Outdoor temperaturelistDisabled
Air qualitylistDisabled
Coil temperaturelistDisabled
Floor surface temperaturelistDisabled
Flow temperaturelistDisabled
Window contact 1listDisabled
Window contact 2listDisabled
Presence sensor 1listDisabled
Presence sensor 2listDisabled
Card holder contactlistDisabled
Humidity CO dimensionlist2 bytes
Main source for temperature valuelistInternal sensor
Additional source temperature valuelistInternal sensor
Relative weightlist50% / 50%
Filter typelistMedium
Main source for temperature valuelistInput
Additional source temperature valuelistInput
Additional source temperature valuelistFrom bus
Thermostat functionlistHeating
AnticondensationlistDisabled
Heating - cooling switch overlistFrom bus
Heating - cooling cyclic sending intervallistNo sending
Max manual temperature changelist±3 °C
Max setpoint temperature changelist±9 °C
Setpoint cyclic sending intervallistNo sending
SceneslistDisabled
Temperature setpoint [°C]float 2…5021
Standby temperature setpoint [°C]float 10…5018
Economy temp. setpoint [°C]float 10…5016
Building protection temp. setpoint [°C]float 2…107
Control typelist2 points hysteresis
Command Communication ObjectlistSeparated
Hysteresislist0.3 K
PWM cycle timetime15
Proportional band [0.1K]unsignedInt 5…10040
Integral time [min]unsignedInt 0…25590
Valve protection functionlistDisabled
FrequencylistOnce a week
Time intervallist10 s
Floor temperature limitationlistDisabled
Temperature limit [°C]float 20…4029
Auxiliary heatinglistDisabled
Communication objectlistSeparated
Offset from setpointlist0.6 K
Disabled from buslistNo
Ventilation for auxiliary heatinglistDisabled
Temperature setpoint [°C]float 2…5023
Standby temperature setpoint [°C]float 10…5026
Economy temp. setpoint [°C]float 10…5028
Building protection temp. setpoint [°C]float 30…5036
Cooling typelistFancoils
Auxiliary coolinglistDisabled
Anticondensation with probelistDisabled
Active anticondensationlistDisabled
Min. change of value to send [%]unsignedInt 0…10010
Anticondensation hysteresis rangelist0.5 K
Control typelist1 speed
Threshold first speed [0.1K]unsignedInt 0…2550
Threshold second speed [0.1K]unsignedInt 0…25510
Threshold third speed [0.1K]unsignedInt 0…25520
Manual operationlistNot depending on the temperature
Hot startlistNo
Use coil battery temperature sensor for dehumidificationlistNo
Speed control hysteresislist0.3 K
Speed proportional band [0.1K]unsignedInt 5…10030
Min. change of value to send [%]unsignedInt 2…4010
Min. temp. to start ventilation [°C]unsignedInt 28…4028
Min. temp. to start dehumidif. [°C]unsignedInt 0…25510
Relative humidity setpoint [%]unsignedInt 0…10065
Relative humidity setpoint [%]list0.6%
Max. temp. diff. to disable dehum. [°C]float 0…500.5
Forced speedlist1 speed
Forced speedunsignedInt 0…10020
Antistratification functionlistDisabled
Antistratification temp. differentiallist2.00 [K/m]
Hysteresislist0.5 K
Disable ventilation from buslistNo
Fan start delaylist0 s
Fan stop delaylist0 s
Download overwritelistDisabled
Scene 1listDisabled
Scene 2listDisabled
Scene 3listDisabled
Scene 4listDisabled
Scene 5listDisabled
Scene 6listDisabled
Scene 7listDisabled
Scene 8listDisabled
Learning modelistDisabled
HVAC modelistComfort
Scene numberunsignedInt 1…641
Activation delaytime0
Windows contacts functionlistDisabled
Presence sensors functionlistDisabled
Presence sensors uselistComfort extension
Thermostat modeslistComfort - standby
Wait time to off modetime60
Absence time to switch HVAC modetime60
SignallistNot inverted
Device operation aslistStand-alone
Main source for temperature valuelistInput 1
Additional source temperature valuelistInput 1
Additional source temperature valuelistInput 2
Actual temperaturelistAlways enabled
Temperature setpointlistEnabled
Relative humiditylistEnabled
Relative humidity setpointlistEnabled
Perceived temperaturelistEnabled
Outdoor temperaturelistEnabled
Air qualitylistEnabled
Activation delay on card insertiontime0
Activation delay on card removaltime0
Backlight intensitylist50%
Automatic backlight dimminglistDisabled
Energy savinglistDisabled
Visualization typelistFull
Time before energy saving modelist10 s
Backlight when in energy saving modelist25%
Behaviour on button presslistBacklight only
Ventilation for auxiliary coolinglistDisabled
Heating typelistRadiators
Heating typelistFancoils
End of manual operationlistTill first telegram from bus
Duration of comfort extensionlistNot allowed
Analog sensors timeouttime300
Flow temperature (project)list14 °C
Min control value [%]unsignedInt 0…3015
Max control value [%]unsignedInt 70…10085
Transmission delay after mode changetime100
Hysteresis positionlistBelow
Hysteresis positionlistAbove
Exit manual mode on setpoint from buslistNo
Logic functionslistDisabled
Logic functionlistDisabled
Logic operationlistOR
Output cyclic transmission intervallistNo sending
Logic object 1listDisabled
Logic object 2listDisabled
Logic object 3listDisabled
Logic object 4listDisabled
Logic object 1 negatedlistNo
Logic object 2 negatedlistNo
Logic object 3 negatedlistNo
Logic object 4 negatedlistNo
Logic object 1 read at startuplistNo
Logic object 2 read at startuplistNo
Logic object 3 read at startuplistNo
Logic object 4 read at startuplistNo
Logic object 1 default valuelistNone
Logic object 2 default valuelistNone
Logic object 3 default valuelistNone
Logic object 4 default valuelistNone
Output sendinglistBoth values
Output updatelistAt value change
Setpoint temperature steplist0.5 °C
Air conditioning applicationlistDisable
Type of control mode datapointlistDPT 20.105
Heat mode valueunsignedInt 0…2551
Cool mode valueunsignedInt 0…2553
Only ventilation mode valueunsignedInt 0…2559
Dehumidify mode valueunsignedInt 0…25514
Power Off mode valueunsignedInt 0…2556
Fan speed 1 valueunsignedInt 0…2551
Fan speed 2 valueunsignedInt 0…2552
Fan speed 3 valueunsignedInt 0…2553
Fan speed 1 valueunsignedInt 0…10020
Fan speed 2 valueunsignedInt 0…10040
Fan speed 3 valueunsignedInt 0…10060
Fan speed 4 valueunsignedInt 0…10080
Fan speed 5 valueunsignedInt 0…100100
Interlocking outputlistNo
Control typelist3 speed
The user can turn offlistYes
The user can turn speed 1listYes
The user can turn speed 2listYes
The user can turn speed 3listYes
The user can turn speed 4listYes
The user can turn speed 5listYes
Automatic mode valueunsignedInt 0…2550
Data Point TypelistDPT 5.100
Fan speed 1 valueunsignedInt 0…10033
Fan speed 2 valueunsignedInt 0…10067
Fan speed 3 valueunsignedInt 0…100100
Fan speed 4 valueunsignedInt 0…2554
Fan speed 5 valueunsignedInt 0…2555
Product typelist-----
Humidity offsetlist0 %
Dehumidification functionlistDisabled
Humidity setpointunsignedInt 20…8055
Humidity hysteresislist0.8%
Disable dehumid. control from buslistNo
Signal from BuslistNot inverted
Subordinated to temperature controllistYes
IntegrationlistNo
Dehumidification start delaytime300
Temperature difference for integrationlist1.5 °C
Hysteresis for integrationlist0.5 K
Humidification functionlistDisabled
Humidity setpointunsignedInt 20…8035
Disable humidification control from buslistNo
Minimum temperature [°C]float 10…5020
Maximum temperature [°C]float 10…5026
Minimum relative humidity [%]unsignedInt 0…10030
Maximum relative humidity [%]unsignedInt 0…10065
Maximum absolute humidity [g/kg x 0,1]unsignedInt 50…200115
Dew-point temperaturelistDisabled
Min. change of value to send [K]list0.2 K
Perceived temperaturelistDisabled
Min. change of value to sendlist0.2 K
LED intensity during Energy SavinglistNo changes
Delay for alarm signallist5 min
Setpoint typelistsingle
Send feedback on status change from buslistdisabled
On status change from UI, discard new status from buslistDisabled
Timeouttime400
Fan AUTO with valuelistDisabled
Fan speed AUTO valueunsignedInt 0…2554
Fan speed AUTO valueunsignedInt 0…2556
Fan speed AUTO valueunsignedInt 0…1000
Enable/disable thermostatlistNo
Comfort temperature setpoint [°C]float 2…5021
Comfort temperature setpoint [°C]float 2…5023
On card insertion switch tolistNone
On card removal switch tolistNone
On card removal switch tolistOff
On card insertion switch tolistOn
Card holder functionlistDisabled

Version history

ApplicationApp noFingerprintFirst seenSizeFile
APPEKEM2TP 1.1 latest$454D78B72026-11-25234 KBDownload

About this file

This is the official ETS product database for the Ekinex S.p.A. Full room temperature controller with LCD (EK-EM2-TP-F), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Ekinex S.p.A.

All Ekinex S.p.A. products