Ekinex S.p.A. EK-CE2-TP Universal interface 4 DI / 2 relais 5A

Universal interface 4 DI / 2 relais 5A EK-CE2-TP

Ekinex S.p.A. · Order number EK-CE2-TP · Heating, cooling and ventilation

Universal interface 4 DI / 2 relais 5A

Download .knxprod APEKCE2TP 0.1 · 238 KB

Product

ManufacturerEkinex S.p.A.
Product nameUniversal interface 4 DI / 2 relais 5A
Order numberEK-CE2-TP
HardwareUniversal interface 4 DI / 2 relais 5A
MediumTwisted Pair
Bus current (mA)10
Rail mountedNo
RegistrationCertified · 2018-02-05
Languagesen-US, de-DE, fr-FR, it-IT
Catalog entryM-00B6_H-00B600000030-1_HP-4345-01-D8D1_CI-EK.2DCE2.2DTP-3
FingerprintD8D1
SHA-256204b95512d4fb7777f58679903447df761feb22f7c81d709afb62117b6ca8f89
First seen2026-11-25
Markets69 markets

Application program: APEKCE2TP 0.1

Application number$4345
Version0.1
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version4.0
Parameters1291
Group objects428
Group objects (428)
NoNameFunctionSizeDPTFlags
1Technical alarm1 Bit1.5 alarmCW
2Input 1 - Lock command1 Bit1.3 enableCWU
2Inputs 1 and 2 - Lock command1 Bit1.3 enableCWU
3Input 1 - Switching status 1-bit object 11 Bit1.1 switchCWTU
3Input 1 - Switching status 2-bits object 12 Bit2.1 switch controlCWTU
3Input 1 - Switching status 1-unsigned byte object 11 Byte5.1 percentage (0..100%)CWTU
3Input 1 - Switching status 1-signed byte object 11 Byte6.1 percentage (-128..127%)CWTU
3Input 1 - Switching status 2-unsigned bytes object 12 Bytes7.1 pulsesCWTU
3Input 1 - Switching status 2-signed bytes object 12 Bytes8.1 pulses differenceCWTU
3Input 1 - Switching status 2-bytes floating value object 12 Bytes9.1 temperature (°C)CWTU
4Input 1 - Switching status 1-bit object 21 Bit1.1 switchCWTU
4Input 1 - Switching status 2-bits object 22 Bit2.1 switch controlCWTU
4Input 1 - Switching status 1-unsigned byte object 21 Byte5.1 percentage (0..100%)CWTU
4Input 1 - Switching status 1-signed byte object 21 Byte6.1 percentage (-128..127%)CWTU
4Input 1 - Switching status 2-unsigned bytes object 22 Bytes7.1 pulsesCWTU
4Input 1 - Switching status 2-signed bytes object 22 Bytes8.1 pulses differenceCWTU
4Input 1 - Switching status 2-bytes floating value object 22 Bytes9.1 temperature (°C)CWTU
5Input 1 - Switching status 1-bit object 31 Bit1.1 switchCWTU
5Input 1 - Switching status 2-bits object 32 Bit2.1 switch controlCWTU
5Input 1 - Switching status 1-unsigned byte object 31 Byte5.1 percentage (0..100%)CWTU
5Input 1 - Switching status 1-signed byte object 31 Byte6.1 percentage (-128..127%)CWTU
5Input 1 - Switching status 2-unsigned bytes object 32 Bytes7.1 pulsesCWTU
5Input 1 - Switching status 2-signed bytes object 32 Bytes8.1 pulses differenceCWTU
5Input 1 - Switching status 2-bytes floating value object 32 Bytes9.1 temperature (°C)CWTU
6Input 1 - Switching status 1-bit object 41 Bit1.1 switchCWTU
6Input 1 - Switching status 2-bits object 42 Bit2.1 switch controlCWTU
6Input 1 - Switching status 1-unsigned byte object 41 Byte5.1 percentage (0..100%)CWTU
6Input 1 - Switching status 1-signed byte object 41 Byte6.1 percentage (-128..127%)CWTU
6Input 1 - Switching status 2-unsigned bytes object 42 Bytes7.1 pulsesCWTU
6Input 1 - Switching status 2-signed bytes object 42 Bytes8.1 pulses differenceCWTU
6Input 1 - Switching status 2-bytes floating value object 42 Bytes9.1 temperature (°C)CWTU
7Input 1 - Switching status 1-bit object 51 Bit1.1 switchCWTU
7Input 1 - Switching status 2-bits object 52 Bit2.1 switch controlCWTU
7Input 1 - Switching status 1-unsigned byte object 51 Byte5.1 percentage (0..100%)CWTU
7Input 1 - Switching status 1-signed byte object 51 Byte6.1 percentage (-128..127%)CWTU
7Input 1 - Switching status 2-unsigned bytes object 52 Bytes7.1 pulsesCWTU
7Input 1 - Switching status 2-signed bytes object 52 Bytes8.1 pulses differenceCWTU
7Input 1 - Switching status 2-bytes floating value object 52 Bytes9.1 temperature (°C)CWTU
8Input 1 - Switching status 1-bit object 61 Bit1.1 switchCWTU
8Input 1 - Switching status 2-bits object 62 Bit2.1 switch controlCWTU
8Input 1 - Switching status 1-unsigned byte object 61 Byte5.1 percentage (0..100%)CWTU
8Input 1 - Switching status 1-signed byte object 61 Byte6.1 percentage (-128..127%)CWTU
8Input 1 - Switching status 2-unsigned bytes object 62 Bytes7.1 pulsesCWTU
8Input 1 - Switching status 2-signed bytes object 62 Bytes8.1 pulses differenceCWTU
8Input 1 - Switching status 2-bytes floating value object 62 Bytes9.1 temperature (°C)CWTU
9Input 1 - Switching status 1-bit object 71 Bit1.1 switchCWTU
9Input 1 - Switching status 2-bits object 72 Bit2.1 switch controlCWTU
9Input 1 - Switching status 1-unsigned byte object 71 Byte5.1 percentage (0..100%)CWTU
9Input 1 - Switching status 1-signed byte object 71 Byte6.1 percentage (-128..127%)CWTU
9Input 1 - Switching status 2-unsigned bytes object 72 Bytes7.1 pulsesCWTU
9Input 1 - Switching status 2-signed bytes object 72 Bytes8.1 pulses differenceCWTU
9Input 1 - Switching status 2-bytes floating value object 72 Bytes9.1 temperature (°C)CWTU
10Input 1 - Switching status 1-bit object 81 Bit1.1 switchCWTU
10Input 1 - Switching status 2-bits object 82 Bit2.1 switch controlCWTU
10Input 1 - Switching status 1-unsigned byte object 81 Byte5.1 percentage (0..100%)CWTU
10Input 1 - Switching status 1-signed byte object 81 Byte6.1 percentage (-128..127%)CWTU
10Input 1 - Switching status 2-unsigned bytes object 82 Bytes7.1 pulsesCWTU
10Input 1 - Switching status 2-signed bytes object 82 Bytes8.1 pulses differenceCWTU
10Input 1 - Switching status 2-bytes floating value object 82 Bytes9.1 temperature (°C)CWTU
11Input 1 - Switching command1 Bit1.1 switchCWTU
11Input 1 - Dedicated stop command1 Bit1.17 triggerCT
11Inputs 1 and 2 - Switching command1 Bit1.1 switchCWTU
11Inputs 1 and 2 - Dedicated stop command1 Bit1.17 triggerCT
12Inputs 1 and 2 - Dimming up / down / stop command4 Bit3.7 dimming controlCT
12Input 1 - Dimming up / down / stop command4 Bit3.7 dimming controlCT
14Input 1 - Stop-step up / down command1 Bit1.7 stepCT
14Inputs 1 and 2 - Stop-step up / down command1 Bit1.7 stepCT
15Inputs 1 and 2 - Move up / down command1 Bit1.8 up/downCT
15Input 1 - Move up / down command1 Bit1.8 up/downCT
16Input 1 - Scene number1 Byte17.1 scene numberCT
16Input 1 - Counter value 1 byte1 Byte5.10 counter pulses (0..255)CRT
16Input 1 - Counter value 2 bytes2 Bytes7.1 pulsesCRT
16Input 1 - Counter value 4 bytes4 Bytes12.1 counter pulses (unsigned)CRT
17Input 1 - Counter reset command1 Bit1.15 resetCW
18Input 1 - Counter runout1 Bit1.5 alarmCRWT
19Input 2 - Lock command1 Bit1.3 enableCWU
20Input 2 - Switching status 1-bit object 11 Bit1.1 switchCWTU
20Input 2 - Switching status 2-bits object 12 Bit2.1 switch controlCWTU
20Input 2 - Switching status 1-unsigned byte object 11 Byte5.1 percentage (0..100%)CWTU
20Input 2 - Switching status 1-signed byte object 11 Byte6.1 percentage (-128..127%)CWTU
20Input 2 - Switching status 2-unsigned bytes object 12 Bytes7.1 pulsesCWTU
20Input 2 - Switching status 2-signed bytes object 12 Bytes8.1 pulses differenceCWTU
20Input 2 - Switching status 2-bytes floating value object 12 Bytes9.1 temperature (°C)CWTU
21Input 2 - Switching status 1-bit object 21 Bit1.1 switchCWTU
21Input 2 - Switching status 2-bits object 22 Bit2.1 switch controlCWTU
21Input 2 - Switching status 1-unsigned byte object 21 Byte5.1 percentage (0..100%)CWTU
21Input 2 - Switching status 1-signed byte object 21 Byte6.1 percentage (-128..127%)CWTU
21Input 2 - Switching status 2-unsigned bytes object 22 Bytes7.1 pulsesCWTU
21Input 2 - Switching status 2-signed bytes object 22 Bytes8.1 pulses differenceCWTU
21Input 2 - Switching status 2-bytes floating value object 22 Bytes9.1 temperature (°C)CWTU
22Input 2 - Switching status 1-bit object 31 Bit1.1 switchCWTU
22Input 2 - Switching status 2-bits object 32 Bit2.1 switch controlCWTU
22Input 2 - Switching status 1-unsigned byte object 31 Byte5.1 percentage (0..100%)CWTU
22Input 2 - Switching status 1-signed byte object 31 Byte6.1 percentage (-128..127%)CWTU
22Input 2 - Switching status 2-unsigned bytes object 32 Bytes7.1 pulsesCWTU
22Input 2 - Switching status 2-signed bytes object 32 Bytes8.1 pulses differenceCWTU
22Input 2 - Switching status 2-bytes floating value object 32 Bytes9.1 temperature (°C)CWTU
23Input 2 - Switching status 1-bit object 41 Bit1.1 switchCWTU
23Input 2 - Switching status 2-bits object 42 Bit2.1 switch controlCWTU
23Input 2 - Switching status 1-unsigned byte object 41 Byte5.1 percentage (0..100%)CWTU
23Input 2 - Switching status 1-signed byte object 41 Byte6.1 percentage (-128..127%)CWTU
23Input 2 - Switching status 2-unsigned bytes object 42 Bytes7.1 pulsesCWTU
23Input 2 - Switching status 2-signed bytes object 42 Bytes8.1 pulses differenceCWTU
23Input 2 - Switching status 2-bytes floating value object 42 Bytes9.1 temperature (°C)CWTU
24Input 2 - Switching status 1-bit object 51 Bit1.1 switchCWTU
24Input 2 - Switching status 2-bits object 52 Bit2.1 switch controlCWTU
24Input 2 - Switching status 1-unsigned byte object 51 Byte5.1 percentage (0..100%)CWTU
24Input 2 - Switching status 1-signed byte object 51 Byte6.1 percentage (-128..127%)CWTU
24Input 2 - Switching status 2-unsigned bytes object 52 Bytes7.1 pulsesCWTU
24Input 2 - Switching status 2-signed bytes object 52 Bytes8.1 pulses differenceCWTU
24Input 2 - Switching status 2-bytes floating value object 52 Bytes9.1 temperature (°C)CWTU
25Input 2 - Switching status 1-bit object 61 Bit1.1 switchCWTU
25Input 2 - Switching status 2-bits object 62 Bit2.1 switch controlCWTU
25Input 2 - Switching status 1-unsigned byte object 61 Byte5.1 percentage (0..100%)CWTU
25Input 2 - Switching status 1-signed byte object 61 Byte6.1 percentage (-128..127%)CWTU
25Input 2 - Switching status 2-unsigned bytes object 62 Bytes7.1 pulsesCWTU
25Input 2 - Switching status 2-signed bytes object 62 Bytes8.1 pulses differenceCWTU
25Input 2 - Switching status 2-bytes floating value object 62 Bytes9.1 temperature (°C)CWTU
26Input 2 - Switching status 1-bit object 71 Bit1.1 switchCWTU
26Input 2 - Switching status 2-bits object 72 Bit2.1 switch controlCWTU
26Input 2 - Switching status 1-unsigned byte object 71 Byte5.1 percentage (0..100%)CWTU
26Input 2 - Switching status 1-signed byte object 71 Byte6.1 percentage (-128..127%)CWTU
26Input 2 - Switching status 2-unsigned bytes object 72 Bytes7.1 pulsesCWTU
26Input 2 - Switching status 2-signed bytes object 72 Bytes8.1 pulses differenceCWTU
26Input 2 - Switching status 2-bytes floating value object 72 Bytes9.1 temperature (°C)CWTU
27Input 2 - Switching status 1-bit object 81 Bit1.1 switchCWTU
27Input 2 - Switching status 2-bits object 82 Bit2.1 switch controlCWTU
27Input 2 - Switching status 1-unsigned byte object 81 Byte5.1 percentage (0..100%)CWTU
27Input 2 - Switching status 1-signed byte object 81 Byte6.1 percentage (-128..127%)CWTU
27Input 2 - Switching status 2-unsigned bytes object 82 Bytes7.1 pulsesCWTU
27Input 2 - Switching status 2-signed bytes object 82 Bytes8.1 pulses differenceCWTU
27Input 2 - Switching status 2-bytes floating value object 82 Bytes9.1 temperature (°C)CWTU
28Input 2 - Switching command1 Bit1.1 switchCWTU
28Input 2 - Dedicated stop command1 Bit1.17 triggerCT
29Input 2 - Dimming up / down / stop command4 Bit3.7 dimming controlCT
31Input 2 - Stop-step up / down command1 Bit1.7 stepCT
32Input 2 - Move up / down command1 Bit1.8 up/downCT
33Input 2 - Scene number1 Byte17.1 scene numberCT
33Input 2 - Counter value 2 bytes2 Bytes7.1 pulsesCRT
33Input 2 - Counter value 1 byte1 Byte5.10 counter pulses (0..255)CRT
33Input 2 - Counter value 4 bytes4 Bytes12.1 counter pulses (unsigned)CRT
34Input 2 - Counter reset command1 Bit1.15 resetCW
35Input 2 - Counter runout1 Bit1.5 alarmCRWT
36Input 3 - Lock command1 Bit1.3 enableCWU
36Inputs 3 and 4 - Lock command1 Bit1.3 enableCWU
37Input 3 - Switching status 1-bit object 11 Bit1.1 switchCWTU
37Input 3 - Switching status 2-bits object 12 Bit2.1 switch controlCWTU
37Input 3 - Switching status 1-unsigned byte object 11 Byte5.1 percentage (0..100%)CWTU
37Input 3 - Switching status 1-signed byte object 11 Byte6.1 percentage (-128..127%)CWTU
37Input 3 - Switching status 2-unsigned bytes object 12 Bytes7.1 pulsesCWTU
37Input 3 - Switching status 2-signed bytes object 12 Bytes8.1 pulses differenceCWTU
37Input 3 - Switching status 2-bytes floating value object 12 Bytes9.1 temperature (°C)CWTU
38Input 3 - Switching status 1-bit object 21 Bit1.1 switchCWTU
38Input 3 - Switching status 2-bits object 22 Bit2.1 switch controlCWTU
38Input 3 - Switching status 1-unsigned byte object 21 Byte5.1 percentage (0..100%)CWTU
38Input 3 - Switching status 1-signed byte object 21 Byte6.1 percentage (-128..127%)CWTU
38Input 3 - Switching status 2-unsigned bytes object 22 Bytes7.1 pulsesCWTU
38Input 3 - Switching status 2-signed bytes object 22 Bytes8.1 pulses differenceCWTU
38Input 3 - Switching status 2-bytes floating value object 22 Bytes9.1 temperature (°C)CWTU
39Input 3 - Switching status 1-bit object 31 Bit1.1 switchCWTU
39Input 3 - Switching status 2-bits object 32 Bit2.1 switch controlCWTU
39Input 3 - Switching status 1-unsigned byte object 31 Byte5.1 percentage (0..100%)CWTU
39Input 3 - Switching status 1-signed byte object 31 Byte6.1 percentage (-128..127%)CWTU
39Input 3 - Switching status 2-unsigned bytes object 32 Bytes7.1 pulsesCWTU
39Input 3 - Switching status 2-signed bytes object 32 Bytes8.1 pulses differenceCWTU
39Input 3 - Switching status 2-bytes floating value object 32 Bytes9.1 temperature (°C)CWTU
40Input 3 - Switching status 1-bit object 41 Bit1.1 switchCWTU
40Input 3 - Switching status 2-bits object 42 Bit2.1 switch controlCWTU
40Input 3 - Switching status 1-unsigned byte object 41 Byte5.1 percentage (0..100%)CWTU
40Input 3 - Switching status 1-signed byte object 41 Byte6.1 percentage (-128..127%)CWTU
40Input 3 - Switching status 2-unsigned bytes object 42 Bytes7.1 pulsesCWTU
40Input 3 - Switching status 2-signed bytes object 42 Bytes8.1 pulses differenceCWTU
40Input 3 - Switching status 2-bytes floating value object 42 Bytes9.1 temperature (°C)CWTU
41Input 3 - Switching status 1-bit object 51 Bit1.1 switchCWTU
41Input 3 - Switching status 2-bits object 52 Bit2.1 switch controlCWTU
41Input 3 - Switching status 1-unsigned byte object 51 Byte5.1 percentage (0..100%)CWTU
41Input 3 - Switching status 1-signed byte object 51 Byte6.1 percentage (-128..127%)CWTU
41Input 3 - Switching status 2-unsigned bytes object 52 Bytes7.1 pulsesCWTU
41Input 3 - Switching status 2-signed bytes object 52 Bytes8.1 pulses differenceCWTU
41Input 3 - Switching status 2-bytes floating value object 52 Bytes9.1 temperature (°C)CWTU
42Input 3 - Switching status 1-bit object 61 Bit1.1 switchCWTU
42Input 3 - Switching status 2-bits object 62 Bit2.1 switch controlCWTU
42Input 3 - Switching status 1-unsigned byte object 61 Byte5.1 percentage (0..100%)CWTU
42Input 3 - Switching status 1-signed byte object 61 Byte6.1 percentage (-128..127%)CWTU
42Input 3 - Switching status 2-unsigned bytes object 62 Bytes7.1 pulsesCWTU
42Input 3 - Switching status 2-signed bytes object 62 Bytes8.1 pulses differenceCWTU
42Input 3 - Switching status 2-bytes floating value object 62 Bytes9.1 temperature (°C)CWTU
43Input 3 - Switching status 1-bit object 71 Bit1.1 switchCWTU
43Input 3 - Switching status 2-bits object 72 Bit2.1 switch controlCWTU
43Input 3 - Switching status 1-unsigned byte object 71 Byte5.1 percentage (0..100%)CWTU
43Input 3 - Switching status 1-signed byte object 71 Byte6.1 percentage (-128..127%)CWTU
43Input 3 - Switching status 2-unsigned bytes object 72 Bytes7.1 pulsesCWTU
43Input 3 - Switching status 2-signed bytes object 72 Bytes8.1 pulses differenceCWTU
43Input 3 - Switching status 2-bytes floating value object 72 Bytes9.1 temperature (°C)CWTU
44Input 3 - Switching status 1-bit object 81 Bit1.1 switchCWTU
44Input 3 - Switching status 2-bits object 82 Bit2.1 switch controlCWTU
44Input 3 - Switching status 1-unsigned byte object 81 Byte5.1 percentage (0..100%)CWTU
44Input 3 - Switching status 1-signed byte object 81 Byte6.1 percentage (-128..127%)CWTU
44Input 3 - Switching status 2-unsigned bytes object 82 Bytes7.1 pulsesCWTU
44Input 3 - Switching status 2-signed bytes object 82 Bytes8.1 pulses differenceCWTU
44Input 3 - Switching status 2-bytes floating value object 82 Bytes9.1 temperature (°C)CWTU
45Input 3 - Switching command1 Bit1.1 switchCWTU
45Input 3 - Dedicated stop command1 Bit1.17 triggerCT
45Inputs 3 and 4 - Switching command1 Bit1.1 switchCWTU
45Inputs 3 and 4 - Dedicated stop command1 Bit1.17 triggerCT
46Input 3 - Dimming up / down / stop command4 Bit3.7 dimming controlCT
46Inputs 3 and 4 - Dimming up / down / stop command4 Bit3.7 dimming controlCT
48Input 3 - Stop-step up / down command1 Bit1.7 stepCT
48Inputs 3 and 4 - Stop-step up / down command1 Bit1.7 stepCT
49Input 3 - Move up / down command1 Bit1.8 up/downCT
49Inputs 3 and 4 - Move up / down command1 Bit1.8 up/downCT
50Input 3 - Scene number1 Byte17.1 scene numberCT
50Input 3 - Counter value 2 bytes2 Bytes7.1 pulsesCRT
50Input 3 - Counter value 1 byte1 Byte5.10 counter pulses (0..255)CRT
50Input 3 - Counter value 4 bytes4 Bytes12.1 counter pulses (unsigned)CRT
51Input 3 - Counter reset command1 Bit1.15 resetCW
52Input 3 - Counter runout1 Bit1.5 alarmCRWT
53Input 4 - Lock command1 Bit1.3 enableCWU
54Input 4 - Switching status 1-bit object 11 Bit1.1 switchCWTU
54Input 4 - Switching status 2-bits object 12 Bit2.1 switch controlCWTU
54Input 4 - Switching status 1-unsigned byte object 11 Byte5.1 percentage (0..100%)CWTU
54Input 4 - Switching status 1-signed byte object 11 Byte6.1 percentage (-128..127%)CWTU
54Input 4 - Switching status 2-unsigned bytes object 12 Bytes7.1 pulsesCWTU
54Input 4 - Switching status 2-signed bytes object 12 Bytes8.1 pulses differenceCWTU
54Input 4 - Switching status 2-bytes floating value object 12 Bytes9.1 temperature (°C)CWTU
55Input 4 - Switching status 1-bit object 21 Bit1.1 switchCWTU
55Input 4 - Switching status 2-bits object 22 Bit2.1 switch controlCWTU
55Input 4 - Switching status 1-unsigned byte object 21 Byte5.1 percentage (0..100%)CWTU
55Input 4 - Switching status 1-signed byte object 21 Byte6.1 percentage (-128..127%)CWTU
55Input 4 - Switching status 2-unsigned bytes object 22 Bytes7.1 pulsesCWTU
55Input 4 - Switching status 2-signed bytes object 22 Bytes8.1 pulses differenceCWTU
55Input 4 - Switching status 2-bytes floating value object 22 Bytes9.1 temperature (°C)CWTU
56Input 4 - Switching status 1-bit object 31 Bit1.1 switchCWTU
56Input 4 - Switching status 2-bits object 32 Bit2.1 switch controlCWTU
56Input 4 - Switching status 1-unsigned byte object 31 Byte5.1 percentage (0..100%)CWTU
56Input 4 - Switching status 1-signed byte object 31 Byte6.1 percentage (-128..127%)CWTU
56Input 4 - Switching status 2-unsigned bytes object 32 Bytes7.1 pulsesCWTU
56Input 4 - Switching status 2-signed bytes object 32 Bytes8.1 pulses differenceCWTU
56Input 4 - Switching status 2-bytes floating value object 32 Bytes9.1 temperature (°C)CWTU
57Input 4 - Switching status 1-bit object 41 Bit1.1 switchCWTU
57Input 4 - Switching status 2-bits object 42 Bit2.1 switch controlCWTU
57Input 4 - Switching status 1-unsigned byte object 41 Byte5.1 percentage (0..100%)CWTU
57Input 4 - Switching status 1-signed byte object 41 Byte6.1 percentage (-128..127%)CWTU
57Input 4 - Switching status 2-unsigned bytes object 42 Bytes7.1 pulsesCWTU
57Input 4 - Switching status 2-signed bytes object 42 Bytes8.1 pulses differenceCWTU
57Input 4 - Switching status 2-bytes floating value object 42 Bytes9.1 temperature (°C)CWTU
58Input 4 - Switching status 1-bit object 51 Bit1.1 switchCWTU
58Input 4 - Switching status 2-bits object 52 Bit2.1 switch controlCWTU
58Input 4 - Switching status 1-unsigned byte object 51 Byte5.1 percentage (0..100%)CWTU
58Input 4 - Switching status 1-signed byte object 51 Byte6.1 percentage (-128..127%)CWTU
58Input 4 - Switching status 2-unsigned bytes object 52 Bytes7.1 pulsesCWTU
58Input 4 - Switching status 2-signed bytes object 52 Bytes8.1 pulses differenceCWTU
58Input 4 - Switching status 2-bytes floating value object 52 Bytes9.1 temperature (°C)CWTU
59Input 4 - Switching status 1-bit object 61 Bit1.1 switchCWTU
59Input 4 - Switching status 2-bits object 62 Bit2.1 switch controlCWTU
59Input 4 - Switching status 1-unsigned byte object 61 Byte5.1 percentage (0..100%)CWTU
59Input 4 - Switching status 1-signed byte object 61 Byte6.1 percentage (-128..127%)CWTU
59Input 4 - Switching status 2-unsigned bytes object 62 Bytes7.1 pulsesCWTU
59Input 4 - Switching status 2-signed bytes object 62 Bytes8.1 pulses differenceCWTU
59Input 4 - Switching status 2-bytes floating value object 62 Bytes9.1 temperature (°C)CWTU
60Input 4 - Switching status 1-bit object 71 Bit1.1 switchCWTU
60Input 4 - Switching status 2-bits object 72 Bit2.1 switch controlCWTU
60Input 4 - Switching status 1-unsigned byte object 71 Byte5.1 percentage (0..100%)CWTU
60Input 4 - Switching status 1-signed byte object 71 Byte6.1 percentage (-128..127%)CWTU
60Input 4 - Switching status 2-unsigned bytes object 72 Bytes7.1 pulsesCWTU
60Input 4 - Switching status 2-signed bytes object 72 Bytes8.1 pulses differenceCWTU
60Input 4 - Switching status 2-bytes floating value object 72 Bytes9.1 temperature (°C)CWTU
61Input 4 - Switching status 1-bit object 81 Bit1.1 switchCWTU
61Input 4 - Switching status 2-bits object 82 Bit2.1 switch controlCWTU
61Input 4 - Switching status 1-unsigned byte object 81 Byte5.1 percentage (0..100%)CWTU
61Input 4 - Switching status 1-signed byte object 81 Byte6.1 percentage (-128..127%)CWTU
61Input 4 - Switching status 2-unsigned bytes object 82 Bytes7.1 pulsesCWTU
61Input 4 - Switching status 2-signed bytes object 82 Bytes8.1 pulses differenceCWTU
61Input 4 - Switching status 2-bytes floating value object 82 Bytes9.1 temperature (°C)CWTU
62Input 4 - Switching command1 Bit1.1 switchCWTU
62Input 4 - Dedicated stop command1 Bit1.17 triggerCT
63Input 4 - Dimming up / down / stop command4 Bit3.7 dimming controlCT
65Input 4 - Stop-step up / down command1 Bit1.7 stepCT
66Input 4 - Move up / down command1 Bit1.8 up/downCT
67Input 4 - Scene number1 Byte17.1 scene numberCT
67Input 4 - Counter value 2 bytes2 Bytes7.1 pulsesCRT
67Input 4 - Counter value 1 byte1 Byte5.10 counter pulses (0..255)CRT
67Input 4 - Counter value 4 bytes4 Bytes12.1 counter pulses (unsigned)CRT
68Input 4 - Counter reset command1 Bit1.15 resetCW
69Input 4 - Counter runout1 Bit1.5 alarmCRWT
70Logic function 1 - Input 11 Bit1.1 switchCWTU
71Logic function 1 - Input 21 Bit1.1 switchCWTU
72Logic function 1 - Input 31 Bit1.1 switchCWTU
73Logic function 1 - Input 41 Bit1.1 switchCWTU
74Logic function 1 - Output1 Bit1.1 switchCRT
75Logic function 2 - Input 11 Bit1.1 switchCWTU
76Logic function 2 - Input 21 Bit1.1 switchCWTU
77Logic function 2 - Input 31 Bit1.1 switchCWTU
78Logic function 2 - Input 41 Bit1.1 switchCWTU
79Logic function 2 - Output1 Bit1.1 switchCRT
80Logic function 3 - Input 11 Bit1.1 switchCWTU
81Logic function 3 - Input 21 Bit1.1 switchCWTU
82Logic function 3 - Input 31 Bit1.1 switchCWTU
83Logic function 3 - Input 41 Bit1.1 switchCWTU
84Logic function 3 - Output1 Bit1.1 switchCRT
85Logic function 4 - Input 11 Bit1.1 switchCWTU
86Logic function 4 - Input 21 Bit1.1 switchCWTU
87Logic function 4 - Input 31 Bit1.1 switchCWTU
88Logic function 4 - Input 41 Bit1.1 switchCWTU
89Logic function 4 - Output1 Bit1.1 switchCRT
90Input 1 - Temperature value2 Bytes9.1 temperature (°C)CRT
91Input 1 - Temperature threshold 1 - Switch1 Bit1.1 switchCRT
92Input 1 - Temperature threshold 2 - Switch1 Bit1.1 switchCRT
93Thermostat - Room temperature (from bus)2 Bytes9.1 temperature (°C)CWTU
94Thermostat - Humidity (2 bytes, from bus)2 Bytes9.7 humidity (%)CWTU
95Thermostat - Humidity (1 byte, from bus)1 Byte5.1 percentage (0..100%)CWTU
96Thermostat - Antistratification temperature (from bus)2 Bytes9.1 temperature (°C)CWTU
97Thermostat - Outdoor temperature (from bus)2 Bytes9.1 temperature (°C)CWTU
98Thermostat - Coil temperature (from bus)2 Bytes9.1 temperature (°C)CWTU
99Thermostat - Floor temperature (from bus)2 Bytes9.1 temperature (°C)CWTU
100Thermostat - Flow temperature (from bus)2 Bytes9.1 temperature (°C)CWTU
101Thermostat - Windows contact sensor 1 (from bus)1 Bit1.19 window/doorCWTU
102Thermostat - Windows contact sensor 2 (from bus)1 Bit1.19 window/doorCWTU
103Thermostat - Presence sensor 1 (from bus)1 Bit1.18 occupancyCWTU
104Thermostat - Presence sensor 2 (from bus)1 Bit1.18 occupancyCWTU
105Thermostat - Contact of card holder (from bus)1 Bit1.18 occupancyCWTU
106Thermostat - Anticondensation (from bus)1 Bit1.1 switchCWTU
107Thermostat - Weighted temperature2 Bytes9.1 temperature (°C)CRT
108Thermostat - Heating/cooling status out1 Bit1.100 heating/coolingCRT
109Thermostat - Heating/cooling status in1 Bit1.100 heating/coolingCW
110Thermostat - HVAC mode in1 Byte20.102 HVAC modeCW
111Thermostat - HVAC forced mode in1 Byte20.102 HVAC modeCW
112Thermostat - HVAC mode out1 Byte20.102 HVAC modeCRT
113Thermostat - HVAC manual mode1 Byte20.102 HVAC modeCWTU
114Thermostat - Chrono active status1 Bit1.11 stateCRT
115Thermostat - Actual setpoint2 Bytes9.1 temperature (°C)CRT
116Thermostat - Manual setpoint2 Bytes9.1 temperature (°C)CW
117Thermostat - Comfort setpoint (heating)2 Bytes9.1 temperature (°C)CRWTU
117Thermostat - Input setpoint2 Bytes9.1 temperature (°C)CRWTU
118Thermostat - Comfort setpoint (cooling)2 Bytes9.1 temperature (°C)CRWTU
119Thermostat - Standby setpoint (heating)2 Bytes9.1 temperature (°C)CRWTU
119Thermostat - Standby offset (heating)2 Bytes9.2 temperature difference (K)CRWTU
120Thermostat - Standby setpoint (cooling)2 Bytes9.1 temperature (°C)CRWTU
120Thermostat - Standby offset (cooling)2 Bytes9.2 temperature difference (K)CRWTU
121Thermostat - Economy setpoint (heating)2 Bytes9.1 temperature (°C)CRWTU
121Thermostat - Economy offset (heating)2 Bytes9.2 temperature difference (K)CRWTU
122Thermostat - Economy setpoint (cooling)2 Bytes9.1 temperature (°C)CRWTU
122Thermostat - Economy offset (cooling)2 Bytes9.2 temperature difference (K)CRWTU
123Thermostat - Building protection setpoint (heating)2 Bytes9.1 temperature (°C)CRWTU
124Thermostat - Building protection setpoint (cooling)2 Bytes9.1 temperature (°C)CRWTU
125Thermostat - Room temperature controller status1 Bit1.3 enableCRT
126Thermostat - Heating out command1 Byte5.1 percentage (0..100%)CRT
126Thermostat - Heating out command1 Bit1.1 switchCRT
126Thermostat - Heating and cooling out command1 Bit1.1 switchCRT
126Thermostat - Heating and cooling out command1 Byte5.1 percentage (0..100%)CRT
127Thermostat - Cooling out command1 Byte5.1 percentage (0..100%)CRT
127Thermostat - Cooling out command1 Bit1.1 switchCRT
128Thermostat - Auxiliary heating output command1 Bit1.1 switchCRT
128Thermostat - Auxiliary heating and cooling output command1 Bit1.1 switchCRT
129Thermostat - Auxiliary cooling output command1 Bit1.1 switchCRT
130Thermostat - Auxiliary heating disable1 Bit1.3 enableCW
131Thermostat - Auxiliary cooling disable1 Bit1.3 enableCW
132Thermostat - Fan continuous speed1 Byte5.1 percentage (0..100%)CRT
133Thermostat - Fan speed 11 Bit1.1 switchCRT
134Thermostat - Fan speed 21 Bit1.1 switchCRT
135Thermostat - Fan speed 31 Bit1.1 switchCRT
136Thermostat - Fan control disable1 Bit1.2 booleanCW
137Thermostat - Alarm text14 Bytes16.0 Character String (ASCII)CRT
138Thermostat - Manual setpoint active status1 Bit1.11 stateCRWTU
139Thermostat - Fan manual speed1 Byte5.10 counter pulses (0..255)CRWTU
140Thermostat - Fan speed1 Byte5.10 counter pulses (0..255)CRT
141Thermostat - Fan manual active status1 Bit1.11 stateCRWTU
142Thermostat - Room temperature control alarm1 Bit1.5 alarmCRT
143Thermostat - Disable room temperature controller1 Bit1.1 switchCW
144Thermostat - Dew-point temperature2 Bytes9.1 temperature (°C)CRT
145Thermostat - Relative humidity setpoint for dehumidification2 Bytes9.7 humidity (%)CRWTU
146Thermostat - Relative humidity setpoint for humidification2 Bytes9.7 humidity (%)CRWTU
147Thermostat - Dehumidification command1 Bit1.1 switchCRT
148Thermostat - Dehumidification integration control1 Bit1.1 switchCRT
149Thermostat - Dehumidification integration control1 Bit1.1 switchCRT
150Thermostat - Dehumidification control disable1 Bit1.2 booleanCW
151Thermostat - Humidification command1 Bit1.1 switchCRT
152Thermostat - Humidification control disable1 Bit1.2 booleanCW
153Thermostat - Anticondensation alarm1 Bit1.5 alarmCRT
154Thermostat - Thermal generator lock1 Bit1.5 alarmCW
155Thermostat - Building protection HVAC mode active1 Bit1.11 stateCRT
156Thermostat - Fan manual speed percentage1 Byte5.1 percentage (0..100%)CRT
157Thermostat - Fan manual speed off status1 Bit1.11 stateCRT
158Output 1A - On/off command1 Bit1.1 switchCRWTU
159Output 1A - On/off status1 Bit1.1 switchCRT
160Output 1A - Staircase lighting start stop command1 Bit1.1 switchCW
161Output 1A - Lock command1 Bit1.3 enableCW
162Output 1A - Forcing command2 Bit2.1 switch controlCW
163Output 1A - Scene number1 Byte17.1 scene numberCW
164Output 1A - kWh counter4 Bytes13.13 active energy (kWh)CRT
165Output 1A - kWh counter reset command1 Bit1.15 resetCW
166Output 1A - Operating time counter4 Bytes13.100 time lag (s)CRT
167Output 1A - Operating time counter reset command1 Bit1.15 resetCW
168Output 1A - Operating time counter runout1 Bit1.5 alarmCRT
169Output 1B - On/off command1 Bit1.1 switchCRWTU
170Output 1B - On/off status1 Bit1.1 switchCRT
171Output 1B - Staircase lighting start stop command1 Bit1.1 switchCW
172Output 1B - Lock command1 Bit1.3 enableCW
173Output 1B - Forcing command2 Bit2.1 switch controlCW
174Output 1B - Scene number1 Byte17.1 scene numberCW
175Output 1B - kWh counter4 Bytes13.13 active energy (kWh)CRT
176Output 1B - kWh counter reset command1 Bit1.15 resetCW
177Output 1B - Operating time counter4 Bytes13.100 time lag (s)CRT
178Output 1B - Operating time counter reset command1 Bit1.15 resetCW
179Output 1B - Operating time counter runout1 Bit1.5 alarmCRT
180Channel 1 - Move up-down command1 Bit1.8 up/downCW
181Channel 1 - Stop-step up-down command1 Bit1.7 stepCW
182Channel 1 - Dedicated stop command1 Bit1.17 triggerCW
183Channel 1 - Info move1 Bit1.8 up/downCRT
184Channel 1 - Valid current abs position1 Bit1.2 booleanCRT
185Channel 1 - Lock command1 Bit1.3 enableCW
186Channel 1 - Forcing command2 Bit2.8 direction control 1CW
187Channel 1 - Wind alarm1 Bit1.5 alarmCW
188Channel 1 - Frost alarm1 Bit1.5 alarmCW
189Channel 1 - Rain alarm1 Bit1.5 alarmCW
190Channel 1 - Scene number1 Byte17.1 scene numberCW
191Channel 1 - Dimmer blind position command4 Bit3.8 blind controlCW
191Channel 1 - Dimmer shutter position command4 Bit3.8 blind controlCW
191Channel 1 - Dimmer valve position command4 Bit3.8 blind controlCW
192Channel 1 - Abs blind position command1 Byte5.1 percentage (0..100%)CW
192Channel 1 - Abs shutter position command1 Byte5.1 percentage (0..100%)CW
192Channel 1 - Abs valve position command1 Byte5.1 percentage (0..100%)CW
193Channel 1 - Abs blind position status1 Byte5.1 percentage (0..100%)CRT
193Channel 1 - Abs shutter position status1 Byte5.1 percentage (0..100%)CRT
193Channel 1 - Abs valve position status1 Byte5.1 percentage (0..100%)CRT
194Channel 1 - Dimmer slats command4 Bit3.8 blind controlCW
195Channel 1 - Abs slats position command1 Byte5.1 percentage (0..100%)CW
196Channel 1 - Abs slats position status1 Byte5.1 percentage (0..100%)CRT
Parameters (301)
ParameterTypeDefault
Cyclic sendingtime120
Hysteresislist0.4 K
Heating/cooling changeoverlistfrom bus
Digital sensors timeouttime300
Room temperaturelistdisabled
Thermostat functionalitieslistdisabled
Threshold 2listnot active
Temperature offsetlist0.0 °C
Signallistnot inverted
Cyclic reading eachlistno reading
Hysteresis positionlistbelow
Hysteresis positionlistabove
Delay for alarm signallist5 min
Thermostat functionlistheating
Heating - cooling cyclic sending intervallistno sending
Analog sensors timeouttime300
Dehumidification functionlistdisabled
Humidification functionlistdisabled
Flow temperature (project)list14 °C
Relative humiditylistdisabled
Antistratification temperaturelistdisabled
Outdoor temperaturelistdisabled
Coil temperaturelistdisabled
Floor surface temperaturelistdisabled
Flow temperaturelistdisabled
Window contact 1listdisabled
Window contact 2listdisabled
Presence sensor 1listdisabled
Presence sensor 2listdisabled
Card holder contactlistdisabled
Humidity CO dimensionlist2 bytes
Cyclic sending intervallistno sending
Minimum change of value to send [K]float 0…50.5
Anticondensationlistdisabled
Relative weightlist50% / 50%
Setpoint cyclic sending intervallistno sending
Comfort temperature setpoint [°C]float 10…5021
Standby temperature offset [0.1 K]signedInt -50…-10-30
Economy temperature offset [0.1 K]signedInt -80…-10-50
Building protection temperature [°C]float 2…107
Control typelist2 points hysteresis
Command Communication Objectlistseparated
Hysteresislist0.3 K
PWM cycle timetime15
Proportional band [0.1K]unsignedInt 5…10040
Integral time [min]unsignedInt 0…25590
Valve protection functionlistdisabled
Frequencylistonce a week
Time intervallist10 s
Floor temperature limitationlistdisabled
Temperature limit [°C]float 20…4029
Auxiliary heatinglistdisabled
Communication object (CO)listseparated
Offset from setpointlist0.6 K
Disabled from buslistno
Disable temperature controller from buslistno
Signal from buslistnot inverted
HVAC mode after downloadlistno change
Temperature setpoint [°C]float 10…5023
Neutral zone [0.1 K]signedInt 10…8020
Cooling typelistfloor radiant panels
Anticondensation with probelistdisabled
Min control value [%]unsignedInt 0…3015
Min. change of value to send [%]unsignedInt 0…10010
Anticondensation hysteresis rangelist0.5 K
Auxiliary coolinglistdisabled
Control typelist1 speed
Threshold first speed [0.1K]unsignedInt 0…2550
Threshold second speed [0.1K]unsignedInt 0…25510
Threshold third speed [0.1K]unsignedInt 0…25520
Manual operationlistnot depending on the temperature
Hot startlistno
Use coil battery temperature sensor for dehumidificationlistno
Speed control hysteresislist0.3 K
Speed proportional band [0.1K]unsignedInt 5…10030
Min. change of value to send [%]unsignedInt 2…4010
Min. temp. to start ventilation [°C]unsignedInt 28…4028
Min. temp. to start dehumidif. [°C]unsignedInt 0…25510
Relative humidity setpoint [%]unsignedInt 0…10065
Relative humidity setpoint [%]list0.6 %
Max. temp. diff. to disable dehum. [°C]float 0…500.5
Forced speedlist1 speed
Forced speedunsignedInt 0…10020
Antistratification functionlistdisabled
Antistratification temp. differentiallist2.00 [K/m]
Hysteresislist0.5 K
Disable ventilation from buslistno
Fan start delaylist0 s
Fan stop delaylist0 s
Dew-point temperaturelistdisabled
Min. change of value to send [K]list0.2 K
Windows contacts functionlistdisabled
Presence sensors functionlistdisabled
Presence sensors uselistcomfort extension
Thermostat modeslistcomfort - standby
Wait time to building protection modetime60
Absence time to switch HVAC modetime60
Card holder functionlistdisabled
On card insertion switch HVAC mode tolistcomfort
On card removal switch HVAC mode toliststandby
Activation delay on card insertiontime0
Activation delay on card removaltime0
Ventilation for auxiliary coolinglistdisabled
End of manual operationlistat first telegram from bus
Heating typelistradiators
Heating typelistfancoils
Humidity hysteresislist0.8 %
Subordinated to temperature controllistyes
Humidity setpointunsignedInt 20…8055
Integrationlistno
Dehumidification start delaytime300
Temperature difference for integrationlist1.5 °C
Hysteresis for integrationlist0.5 K
Disable dehumid. control from buslistno
Humidity setpointunsignedInt 20…8035
Disable humidification control from buslistno
Max control value [%]unsignedInt 70…10085
Active anticondensationlistdisabled
Transmission delay after mode changetime400
Channel 1 (Input)listindependent or single
Channel 2 (Input)listindependent or single
Delay after bus voltage recoverytime400
Input 1listenabled DIN
Long press timetime80
Lock functionlistdisabled
Invert lock device signallistnot inverted
Lock after bus recoverylistno
Typelistsend values or sequences
Number of Communication ObjectsunsignedInt 1…81
Eventlistactivation / release
Behavior at lockinglistnone
Behavior at unlockinglistnone
Send cyclicallylistnone
Cyclic sending intervaltime120
Send delaytime0
Communication object dimensionlist1 bit value
Reaction to activationlisttoggle
Reaction to releaselistoff
Reaction to short presslisttoggle
Reaction to long presslistoff
Reaction to activationlistenable on / down
Reaction to releaselistdisable
Reaction to short presslistenable on / down
Reaction to long presslistdisable
Reaction to activationlistsend value 1
Reaction to releaselistnone
Reaction to short presslistsend value 1
Reaction to long presslistnone
Value 1unsignedInt 0…2550
Value 2unsignedInt 0…2550
Value 1signedInt -128…1270
Value 2signedInt -128…1270
Value 1unsignedInt 0…655350
Value 2unsignedInt 0…655350
Value 1signedInt -32768…327670
Value 2signedInt -32768…327670
Value 1float -671088.64…670760.960
Value 2float -671088.64…670760.960
Reaction to activationliston
Reaction to short pressliston
Toggle modelistenabled
Short / long actionlistoff / darker
Up / down actionlistup
Venetian blind modelistdisabled
Learning modelistdisabled
Scene activationlistsend first scene only
First scene numberunsignedInt 1…641
Second scene numberunsignedInt 1…642
Input 2listenabled
Typelistdimming
1 and 2 uselistA increases, B decreases
1 and 2 uselistA up, B down
1 and 2 uselistA on, B off
Input 3listenabled
Input 4listenabled
3 and 4 uselistA on, B off
3 and 4 uselistA increases, B decreases
3 and 4 uselistA up, B down
Reaction to long presslistdarker
Value 1unsignedInt 0…1000
Value 2unsignedInt 0…1000
Logic functionlistdisabled
Logic operationlistOR
Output cyclic transmission intervallistno sending
Logic object 1listdisabled
Logic object 2listdisabled
Logic object 3listdisabled
Logic object 4listdisabled
Logic object 1 negatedlistno
Logic object 2 negatedlistno
Logic object 3 negatedlistno
Logic object 4 negatedlistno
Logic object 1 read at startuplistno
Logic object 2 read at startuplistno
Logic object 3 read at startuplistno
Logic object 4 read at startuplistno
Logic object 1 default valuelistnone
Logic object 2 default valuelistnone
Logic object 3 default valuelistnone
Logic object 4 default valuelistnone
Output sendinglistboth values
Output updatinglistat the change of value
Technical alarmlistdisabled
Debounce timetime5
Contact typelistNO (normally open)
Counter dimensionlistfrom 0 to 255 (1 byte)
Max valueunsignedInt 0…255255
Max valueunsignedInt 0…6553565535
Max valueunsignedInt 0…42949672954294967295
Setpoint typelistsingle
Ventilation for auxiliary heatinglistdisabled
Threshold 1listnot active
Value [°C]float 0…507
Value [°C]float 0…5045
Filter typelistmedium
Temperature setpoint [°C]float 10…5021
Standby temperature offset [0.1 K]signedInt 10…5030
Economy temperature offset [0.1 K]signedInt 10…8050
Building protection temperature [°C]float 10…5036
Operating energy/time counterlistdisabled
Energy/time cyclic sendingtime0
Output load [W]float -671088.64…670760.961000
Activation delaytime0
Scene numberunsignedInt 1…641
Output behaviorliston
Scene 8listdisabled
Scene 7listdisabled
Scene 6listdisabled
Scene 5listdisabled
Scene 4listdisabled
Scene 3listdisabled
Scene 2listdisabled
Scene 1listdisabled
Download overwrites learned behaviorlistyes
Scenes functionlistdisabled
Outputlist2 binary outputs
Output 1Alistenabled
Relay operationlistnot inverted
Behavior at bus onlistnone
Status feedback telegramlistenabled
Behavior after downloadlistnone
Behavior at bus onlistprevious state
Behavior after downloadlistno change
Bus on positionunsignedInt 0…1000
Delay after bus voltage recoverytime300
Bus on slats positionunsignedInt 0…1000
Transmission cycle timetime0
After download positionunsignedInt 0…1000
On delay timetime0
After download slats positionunsignedInt 0…1000
Off delay timetime0
Staircase lighting timetime60
Locking functionlistdisabled
Lock device signallistnot inverted
After bus recoverylistprevious state
Lock start positionunsignedInt 0…1000
Pre-warning timetime10
Lock start slats positionunsignedInt 0…1000
Interruption timetime50
Lock end positionunsignedInt 0…1000
Lock end slat positionunsignedInt 0…1000
Forcing functionlistdisabled
Staircase lighting functionlistdisabled
Behavior end forced controllistnone
Manual offlistdisabled
Retriggerablelistdisabled
Pre-warninglistdisabled
Behavior after bus recoverylistnot forced
Behavior at bus offlistno change
End forced positionunsignedInt 0…1000
Behavior at lockinglistoff
End forced slat positionunsignedInt 0…1000
Behavior at unlockinglistvalue before locking
Bus recovery forced positionunsignedInt 0…1000
Bus recovery forced slat positionunsignedInt 0…1000
Behavior end forced controllistno change
Behavior after bus recoverylistprevious state
Reaction to windlistnone
Reaction to frostlistnone
Reaction to rainlistnone
Meteo alarmslistdisabled
Wind timeouttime0
Frost timeouttime0
Rain timeouttime0
Action at the end of alarmlistnone
Output behaviorlistfully opened
Scene positionunsignedInt 0…1000
Scene slats positionunsignedInt 0…1000
Output 1Blistenabled
Uselistvalve
Three-way modelistdisabled
Position control with dimmerlistno
Slats control with dimmerlistno
Reversion pause timetime300
Open timetime15
Move up timetime15
Behavior at unlockinglistoff
Close timetime15
Move down timetime15
Slat movement timetime15
Slat step timetime100

Version history

ApplicationApp noFingerprintFirst seenSizeFile
APEKCE2TP 0.1 latest$4345D8D12026-11-25238 KBDownload
APEKCE2TP 0.1$4345D8D12026-11-25238 KBDownload
APEKCE2TP 0.1$4345D8D12026-11-25238 KBDownload

About this file

This is the official ETS product database for the Ekinex S.p.A. Universal interface 4 DI / 2 relais 5A (EK-CE2-TP), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Ekinex S.p.A.