SCN-LK001.03S Line/Segment Coupler with Data Secure/Secure Proxy (for HW from R7.0) SCN-LK001.03S
MDT technologies GmbH · Order number SCN-LK001.03S · System Devices › Couplers
The application is compatible with the hardware from R7.0.
Download .knxprod Line/Segment Coupler/Secure Proxy 1.0 · 116 KB
Product
| Manufacturer | MDT technologies GmbH |
|---|---|
| Product name | SCN-LK001.03S Line/Segment Coupler with Data Secure/Secure Proxy (for HW from R7.0) |
| Order number | SCN-LK001.03S |
| Product text | SCN-LK001.03S Line/Segment Coupler with Data Secure/Secure Proxy |
| Hardware | Linienkoppler |
| Medium | Twisted Pair |
| Bus current (mA) | 7.5 |
| Rail mounted | Yes |
| Width (mm) | 35 |
| Device kind | Coupler |
| Registration | Certified · 2026-04-17 |
| Languages | de-DE, en-US |
| Catalog entry | M-0083_H-57.2F4-1-O0072_HP-0237-10-7F46-O0072_CI-SCN.2DLK001.2E03S-1 |
| Fingerprint | 7F46 |
| SHA-256 | 00245c859d717544d945c87ee510ef05b55bf727d4ab5d51eb56918d2735f03f |
| First seen | 2026-11-25 |
| Markets | 69 markets |
Application program: Line/Segment Coupler/Secure Proxy 1.0
| Application number | $0237 |
|---|---|
| Version | 1.0 |
| Mask version | MV-0912 (Coupler 0912) |
| KNX Data Secure | Yes |
| Minimum ETS version | 6.0 |
| Parameters | 43 |
| Group objects | 0 |
Group objects (0)
| No | Name | Function | Size | DPT | Flags |
|---|
Parameters (33)
| Parameter | Type | Default |
|---|---|---|
| Fallback time for Manual operation | list | 1 h |
| Time for error LED | list | 2 s |
| Manual operation | list | pass all telegrams |
| LDdef2 | unsignedInt 0…255 | 255 |
| LKgroupConfig | unsignedInt 0…255 | 51 |
| Telegram routing | list | Groups and Physical: filter |
| mainBasicBlock | list | 0 |
| mainBasicFilter | list | 0 |
| mainBasicRouteGroup | list | 0 |
| mainBasicRoute | list | 0 |
| mainBasicConfig | list | 0 |
| physical telegrams: blocked | list | 0 |
| physical telegrams: filtered | list | 0 |
| physical telegrams: route filter | list | 0 |
| physical telegrams: route | list | 0 |
| physical telegrams: configure | list | 0 |
| Group telegrams: Main group 0 … 13 | list | filter |
| Physical telegrams | list | block |
| Physical telegrams: Repetition for errors on Main line | list | up to 3 repetitions |
| Group telegrams: Repetition for errors on Main line | list | up to 3 repetitions |
| Confirm telegrams on Main line | list | if routed |
| Confirm own telegrams | list | not active |
| subBasicBlock | list | 0 |
| subBasicFilter | list | 0 |
| subBasicRouteGroup | list | 0 |
| subBasicRoute | list | 0 |
| subBasicConfig | list | 0 |
| Physical telegrams: Repetition for errors on line (Sub) | list | up to 3 repetitions |
| Group telegrams: Repetition for errors on line (Sub) | list | up to 3 repetitions |
| Confirm telegrams on line (Sub) | list | if routed |
| Programming via line (Sub) | list | allow |
| Group telegrams: Main group 14 … 31 | list | route all (not recommended) |
| 13062016 | text |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Line/Segment Coupler/Secure Proxy 1.0 latest | $0237 | 7F46 | 2026-11-25 | 116 KB | Download |
About this file
This is the official ETS product database for the MDT technologies GmbH SCN-LK001.03S Line/Segment Coupler with Data Secure/Secure Proxy (for HW from R7.0) (SCN-LK001.03S), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from MDT technologies GmbH
- KNX Gateway for Daikin residential air conditioning units, flush mounted SCN-ACG0DAI.01
- KNX Gateway for Mitsubishi air conditioning units, flush mounted SCN-ACG0MIT.01
- KNX Gateway for Panasonic Etherea air conditioning units, flush mounted SCN-ACG0PAN.01
- KNX Gateway for Daikin commercial air conditioning units, flush mounted SCN-ACG1DAI.01
- DALI Control 64 Gateway SCN-DA641.04
- DALI Control Pro64 Gateway SCN-DA641P.04S
- DALI Control 2x64 Gateway SCN-DA642.04
- Dali Control Broadcast Gateway SCN-DABC4.01
- DaliControl 16 SCN-DALI16.03
- DaliControl 32 SCN-DALI32.03
- DaliControl IP 64 SCN-DALI64.03
- SCN-IP000.02/.03 IP Interface without Secure SCN-IP000.02