KNX Gateway for Daikin residential air conditioning units, flush mounted SCN-ACG0DAI.01
MDT technologies GmbH · Order number SCN-ACG0DAI.01 · System Devices › KNX Gateways
Download .knxprod KNX Gateway for Daikin residential air conditioning units, flush mounted 0.4 · 130 KB
Product
| Manufacturer | MDT technologies GmbH |
|---|---|
| Product name | KNX Gateway for Daikin residential air conditioning units, flush mounted |
| Order number | SCN-ACG0DAI.01 |
| Hardware | DK AC Interface |
| Medium | Twisted Pair |
| Bus current (mA) | 6 |
| Rail mounted | No |
| Registration | Certified · 2026-06-17 |
| Languages | de-DE, en-US, es-ES |
| Catalog entry | M-0083_H-INT01-1-O0077_HP-0481-04-D684-O0077_CI-SCN.2DACG0DAI.2E01-0 |
| Fingerprint | D684 |
| SHA-256 | 9c501cc7034b21762992378d9dade89cf04d403be7899deb1f0965a7f4289e93 |
| First seen | 2026-11-25 |
| Markets | 69 markets |
Application program: KNX Gateway for Daikin residential air conditioning units, flush mounted 0.4
| Application number | $0481 |
|---|---|
| Version | 0.4 |
| Mask version | MV-0025 (2.5) |
| KNX Data Secure | No |
| Parameters | 55 |
| Group objects | 50 |
Group objects (50)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | ON / OFF | 1 = ON, 0 = OFF | 1 Bit | 1.1 switch | CRWT |
| 1 | Mode | 0 = Auto, 1 = Heat, 2 = Dry, 3 = Fan, 4 = Cool | 1 Byte | CRT | |
| 2 | HVAC Mode | 0 = Auto, 1 = Heat, 3 = Cool, 9 = Fan, 14 = Dry | 1 Byte | CRT | |
| 3 | Mode: Cool/Heat | 0 = Cool, 1 = Heat | 1 Bit | DPT.1 | CRWT |
| 4 | Mode: Text | Maximum: 14 characters | 14 Bytes | 16.1 Character String (ISO 8859-1) | CRT |
| 5 | Mode: Auto | 1 = Mode Auto Active | 1 Bit | 1.2 boolean | CRWT |
| 6 | Mode: Heat | 1 = Mode Heat Active | 1 Bit | 1.2 boolean | CRWT |
| 7 | Mode: Dry | 1 = Mode Dry Active | 1 Bit | 1.2 boolean | CRWT |
| 8 | Mode: Cool | 1 = Mode Cool Active | 1 Bit | 1.2 boolean | CRWT |
| 9 | Mode: Fan | 1 = Mode Fan Active | 1 Bit | 1.2 boolean | CRWT |
| 10 | Setpoint Temperature | ºC | 2 Bytes | 9.1 temperature (°C) | CRWT |
| 11 | Setpoint Temperature [+/-] | 0 = Up, 1 = Down | 1 Bit | 1.8 up/down | CW |
| 11 | Setpoint Temperature [+/-] | 0 = Decrease, 1 = Increase | 1 Bit | DPT.1 | CW |
| 12 | Virtual Setpoint Temperature | ºC | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 13 | Virtual Ambient Temperature | ºC | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 14 | Fan | 0 = Auto, 1 = Low, 2 = M1, 3 = M2, 4 = M3, 5 = High | 1 Byte | CRT | |
| 15 | Fan: Text | Maximum: 14 characters | 14 Bytes | 16.1 Character String (ISO 8859-1) | CRT |
| 16 | Fan Speed [+/-] | 0 = Up, 1 = Down | 1 Bit | 1.8 up/down | CW |
| 16 | Fan Speed [+/-] | 0 = Decrease, 1 = Increase | 1 Bit | DPT.1 | CW |
| 17 | Fan: Auto | 1 = Fan Speed Auto | 1 Bit | 1.2 boolean | CRWT |
| 18 | Fan: Low | 1 = Fan Speed Low | 1 Bit | 1.2 boolean | CRWT |
| 19 | Fan: Mid1 | 1 = Fan Speed Mid 1 | 1 Bit | 1.2 boolean | CRWT |
| 20 | Fan: Mid2 | 1 = Fan Speed Mid 2 | 1 Bit | 1.2 boolean | CRWT |
| 21 | Fan: Mid3 | 1 = Fan Speed Mid 3 | 1 Bit | 1.2 boolean | CRWT |
| 22 | Fan: High | 1 = Fan Speed High | 1 Bit | 1.2 boolean | CRWT |
| 23 | Swing | 0 = Off, 1 = Vert, 2 = Hori, 3 = Both | 1 Byte | CRT | |
| 24 | Swing: Text | Maximum: 14 characters | 14 Bytes | 16.1 Character String (ISO 8859-1) | CRT |
| 25 | Swing: Vertical | 1 = Swing Vertical | 1 Bit | 1.1 switch | CRWT |
| 26 | Swing: Horizontal | 1 = Swing Horizontal | 1 Bit | 1.1 switch | CRWT |
| 27 | Error | 1 = Error in AC Unit | 1 Bit | DPT.1 | CRT |
| 28 | Error Code | AC Unit Error Code | 2 Bytes | CRT | |
| 29 | Window | 1 = Closed, 0 = Open | 1 Bit | 1.9 open/close | CWTU |
| 30 | Device Enable | 1 = Enabled, 0 = Disabled | 1 Bit | 1.3 enable | CRWT |
| 31 | Remote Control Enable | 1 = Enabled, 0 = Disabled | 1 Bit | 1.3 enable | CRWT |
| 32 | Time Counter | Hours | 2 Bytes | 7.1 pulses | CRWT |
| 33 | Humidifying: Mode | 0 = Off, 1 = Low, 2 = Stan, 3 = High, 4 = Cont | 1 Byte | CRT | |
| 34 | Humidifying: Text | Maximum: 14 characters | 14 Bytes | 16.1 Character String (ISO 8859-1) | CRWT |
| 35 | Humidifying: Off | 1 = Humidifying Off | 1 Bit | 1.2 boolean | CRWT |
| 36 | Humidifying: Low | 1 = Humidifying Low | 1 Bit | 1.2 boolean | CRWT |
| 37 | Humidifying: Standard | 1 = Humidifying Standard | 1 Bit | 1.2 boolean | CRWT |
| 38 | Humidifying: High | 1 = Humidifying High | 1 Bit | 1.2 boolean | CRWT |
| 39 | Humidifying: Continuous | 1 = Humidifying Continuous | 1 Bit | 1.2 boolean | CRWT |
| 40 | Save/Execute Scene | 0 = Scene 1, 1 = Scene 2 | 1 Byte | CW | |
| 41 | Current Scene | 0 = Scene 1, 1 = Scene 2 | 1 Byte | CRT | |
| 42 | Save Scene 1 | 1 = Save Scene 1 | 1 Bit | 1.2 boolean | CW |
| 43 | Save Scene 2 | 1 = Save Scene 2 | 1 Bit | 1.2 boolean | CW |
| 44 | Execute Scene 1 | 1 = Execute Scene 1 | 1 Bit | 1.2 boolean | CW |
| 45 | Execute Scene 2 | 1 = Execute Scene 2 | 1 Bit | 1.2 boolean | CW |
| 46 | Auto Heat | 1 = Auto Heat Active | 1 Bit | 1.2 boolean | CRT |
| 47 | Auto Cool | 1 = Auto Cool Active | 1 Bit | 1.2 boolean | CRT |
Parameters (46)
| Parameter | Type | Default |
|---|---|---|
| AC unit type | list | CONVENTIONAL |
| Features | text | Two Swing Modes; No Humidifier |
| Features | text | Two Swing Modes; With Humidifier |
| Features | text | No Swing; No Humidifier |
| Window minutes | unsignedInt 0…30 | 0 |
| Send object values to KNX bus on startup | list | Yes |
| When window closes go to last state | list | No |
| Virtual temperature control | list | No |
| Dual Setpoint Temperature | list | No |
| Temperature Units | list | Celsius |
| Mode [1byte] object type | list | DPT_20.105_HVAC_Mode |
| Show "Mode: Cool/Heat" object (1 Bit) | list | No |
| Show Device Objects | list | No |
| Show Mode Bits | list | No |
| Show Fan Bits | list | No |
| Show Swing Bits | list | No |
| Show Humidifying Objects | list | No |
| Show Humidifying Bits | list | No |
| Show Scene Objects | list | No |
| Show Scene Bits | list | No |
| Show Auto Details | list | No |
| Enable Mode/Fan/Swing/Humi Texts | list | No |
| Show Fan Speed [+/-] object | list | No |
| Fan Speed [+/-] object type | list | DPT_1.007_Step (0=Dec/1=Inc) |
| Show Setpoint Temperature [+/-] object | list | No |
| Setpoint Temperature [+/-] object type | list | DPT_1.007_Step (0=Dec/1=Inc) |
| Mode Auto Text | text | Auto |
| Mode Heat Text | text | Heat |
| Mode Dry Text | text | Dry |
| Mode Fan Text | text | Fan |
| Mode Cool Text | text | Cool |
| Fan Auto text | text | Auto |
| Fan Low text | text | Low |
| Fan Middle-1 text | text | Middle-1 |
| Fan Middle-2 text | text | Middle-2 |
| Fan Middle-3 text | text | Middle-3 |
| Fan High text | text | High |
| Swing Off Text | text | Off |
| Swing Vertical Text | text | Vertical |
| Swing Horizontal Text | text | Horizontal |
| Swing Both Text | text | Both |
| Humidifying Off Text | text | Off |
| Humidifying Low Text | text | Low |
| Humidifying Standard Text | text | Standard |
| Humidifying High Text | text | High |
| Humidifying Continuous Text | text | Continuous |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| KNX Gateway for Daikin residential air conditioning units, flush mounted 0.4 latest | $0481 | D684 | 2026-11-25 | 130 KB | Download |
About this file
This is the official ETS product database for the MDT technologies GmbH KNX Gateway for Daikin residential air conditioning units, flush mounted (SCN-ACG0DAI.01), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from MDT technologies GmbH
- KNX Gateway for Mitsubishi air conditioning units, flush mounted SCN-ACG0MIT.01
- KNX Gateway for Panasonic Etherea air conditioning units, flush mounted SCN-ACG0PAN.01
- KNX Gateway for Daikin commercial air conditioning units, flush mounted SCN-ACG1DAI.01
- DALI Control 64 Gateway SCN-DA641.04
- DALI Control Pro64 Gateway SCN-DA641P.04S
- DALI Control 2x64 Gateway SCN-DA642.04
- Dali Control Broadcast Gateway SCN-DABC4.01
- DaliControl 16 SCN-DALI16.03
- DaliControl 32 SCN-DALI32.03
- DaliControl IP 64 SCN-DALI64.03
- SCN-IP000.02/.03 IP Interface without Secure SCN-IP000.02
- SCN-IP000.03 IP Interface with Secure SCN-IP000.03