SCN-CO2MGS.02 CO2 / VOC Combi Sensor 55 SCN-CO2MGS.02
MDT technologies GmbH · Order number SCN-CO2MGS.02 · Controller › Air quality/CO2 sensor
Download .knxprod Air Quality Sensor with CO2 and VOC sensor 1.2 · 261 KB
Product
| Manufacturer | MDT technologies GmbH |
|---|---|
| Product name | SCN-CO2MGS.02 CO2 / VOC Combi Sensor 55 |
| Order number | SCN-CO2MGS.02 |
| Hardware | Luftqualitätssensor mit CO2- und VOC-Sensor |
| Medium | Twisted Pair |
| Bus current (mA) | 10 |
| Rail mounted | No |
| Registration | Registered · 2022-06-07 |
| Languages | de-DE, en-US, es-ES, fr-FR, it-IT |
| Catalog entry | M-0083_H-271-1_HP-0146-12-1EDD_CI-SCN.2DCO2MGS.2E02-1 |
| Fingerprint | 1EDD |
| SHA-256 | 97d8c6728b2af4fc5249ac701d721fe058c842325bba9d915b81de42d1a2a320 |
| First seen | 2026-11-25 |
| Markets | 69 markets |
Application program: Air Quality Sensor with CO2 and VOC sensor 1.2
| Application number | $0146 |
|---|---|
| Version | 1.2 |
| Mask version | MV-07B0 (System B) |
| KNX Data Secure | No |
| Minimum ETS version | 5.0 |
| Parameters | 244 |
| Group objects | 137 |
Group objects (137)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 1 | CO2 measurement | Send measured value | 2 Bytes | 9.8 parts/million (ppm) | CRT |
| 2 | CO2 measurement | External sensor input | 2 Bytes | 9.8 parts/million (ppm) | CWTU |
| 3 | CO2 measurement | Maximum value exceeded | 1 Bit | 1.5 alarm | CRT |
| 4 | CO2 measurement | Minimum value fallen below | 1 Bit | 1.5 alarm | CRT |
| 5 | CO2 measurement | Error external sensor | 1 Bit | 1.5 alarm | CRT |
| 8 | VOC measurement | Send measured value | 2 Bytes | 9.8 parts/million (ppm) | CRT |
| 8 | VOC measurement | Send measured value | 2 Bytes | DPT.7 | CRT |
| 9 | VOC measurement | External sensor input | 2 Bytes | 9.8 parts/million (ppm) | CWTU |
| 9 | VOC measurement | External sensor input | 2 Bytes | DPT.7 | CWTU |
| 10 | VOC measurement | Maximum value exceeded | 1 Bit | 1.5 alarm | CRT |
| 11 | VOC measurement | Minimum value fallen below | 1 Bit | 1.5 alarm | CRT |
| 12 | VOC measurement | Error external sensor | 1 Bit | 1.5 alarm | CRT |
| 15 | Temperature measurement | Send measured value | 2 Bytes | 9.1 temperature (°C) | CRT |
| 16 | Temperature measurement | External sensor input | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 17 | Temperature measurement | Maximum value exceeded | 1 Bit | 1.5 alarm | CRT |
| 18 | Temperature measurement | Minimum value fallen below | 1 Bit | 1.5 alarm | CRT |
| 19 | Temperature measurement | Error external sensor | 1 Bit | 1.5 alarm | CRT |
| 22 | Relative humidity measurement | Send measured value | 2 Bytes | 9.7 humidity (%) | CRT |
| 23 | Relative humidity measurement | External sensor input | 2 Bytes | 9.7 humidity (%) | CWTU |
| 24 | Relative humidity measurement | Maximum value exceeded | 1 Bit | 1.5 alarm | CRT |
| 25 | Relative humidity measurement | Minimum value fallen below | 1 Bit | 1.5 alarm | CRT |
| 26 | Relative humidity measurement | Error external sensor | 1 Bit | 1.5 alarm | CRT |
| 29 | Air quality traffic light | Output level 1 | 1 Bit | 1.1 switch | CRT |
| 30 | Air quality traffic light | Output level 2 | 1 Bit | 1.1 switch | CRT |
| 31 | Air quality traffic light | Output level 3 | 1 Bit | 1.1 switch | CRT |
| 32 | Air quality traffic light | Output level 4 | 1 Bit | 1.1 switch | CRT |
| 32 | Air quality traffic light | Output level 3 | 1 Bit | 1.1 switch | CRT |
| 33 | Air quality traffic light | Output RGB | 3 Bytes | 232.600 RGB value 3x(0..255) | CRT |
| 33 | Air quality traffic light | Output HSV | 3 Bytes | 232.600 RGB value 3x(0..255) | CRT |
| 34 | Air quality traffic light | Output Scene | 1 Byte | 17.1 scene number | CRT |
| 37 | Air quality controller | Preset setpoint | 2 Bytes | 9.8 parts/million (ppm) | CW |
| 37 | Air quality controller | Preset setpoint | 2 Bytes | DPT.7 | CW |
| 38 | Air quality controller | Actual setpoint | 2 Bytes | 9.8 parts/million (ppm) | CRT |
| 38 | Air quality controller | Actual setpoint | 2 Bytes | DPT.7 | CRT |
| 39 | Air quality controller | CO2 Input 1 | 2 Bytes | 9.8 parts/million (ppm) | CW |
| 39 | Air quality controller | VOC (IAQ Index) Input 1 | 2 Bytes | DPT.7 | CW |
| 39 | Air quality controller | VOC Input 1 | 2 Bytes | 9.8 parts/million (ppm) | CW |
| 40 | Air quality controller | CO2 Input 2 | 2 Bytes | 9.8 parts/million (ppm) | CW |
| 40 | Air quality controller | VOC (IAQ Index) Input 2 | 2 Bytes | DPT.7 | CW |
| 40 | Air quality controller | VOC Input 2 | 2 Bytes | 9.8 parts/million (ppm) | CW |
| 41 | Air quality controller | CO2 Input 3 | 2 Bytes | 9.8 parts/million (ppm) | CW |
| 41 | Air quality controller | VOC (IAQ Index) Input 3 | 2 Bytes | DPT.7 | CW |
| 41 | Air quality controller | VOC Input 3 | 2 Bytes | 9.8 parts/million (ppm) | CW |
| 42 | Air quality controller | CO2 Input 4 | 2 Bytes | 9.8 parts/million (ppm) | CW |
| 42 | Air quality controller | VOC (IAQ Index) Input 4 | 2 Bytes | DPT.7 | CW |
| 42 | Air quality controller | VOC Input 4 | 2 Bytes | 9.8 parts/million (ppm) | CW |
| 43 | Air quality controller | CO2 Input 5 | 2 Bytes | 9.8 parts/million (ppm) | CW |
| 43 | Air quality controller | VOC (IAQ Index) Input 5 | 2 Bytes | DPT.7 | CW |
| 43 | Air quality controller | VOC Input 5 | 2 Bytes | 9.8 parts/million (ppm) | CW |
| 44 | Air quality controller | CO2 Input 6 | 2 Bytes | 9.8 parts/million (ppm) | CW |
| 44 | Air quality controller | VOC (IAQ Index) Input 6 | 2 Bytes | DPT.7 | CW |
| 44 | Air quality controller | VOC Input 6 | 2 Bytes | 9.8 parts/million (ppm) | CW |
| 44 | Air quality controller | Humidity Input 1 | 2 Bytes | 9.7 humidity (%) | CW |
| 45 | Air quality controller | CO2 Input 7 | 2 Bytes | 9.8 parts/million (ppm) | CW |
| 45 | Air quality controller | VOC (IAQ Index) Input 7 | 2 Bytes | DPT.7 | CW |
| 45 | Air quality controller | VOC Input 7 | 2 Bytes | 9.8 parts/million (ppm) | CW |
| 45 | Air quality controller | Humidity Input 2 | 2 Bytes | 9.7 humidity (%) | CW |
| 46 | Air quality controller | CO2 Input 8 | 2 Bytes | 9.8 parts/million (ppm) | CW |
| 46 | Air quality controller | VOC (IAQ Index) Input 8 | 2 Bytes | DPT.7 | CW |
| 46 | Air quality controller | VOC Input 8 | 2 Bytes | 9.8 parts/million (ppm) | CW |
| 46 | Air quality controller | Humidity Input 3 | 2 Bytes | 9.7 humidity (%) | CW |
| 47 | Air quality controller | CO2 Input 9 | 2 Bytes | 9.8 parts/million (ppm) | CW |
| 47 | Air quality controller | VOC (IAQ Index) Input 9 | 2 Bytes | DPT.7 | CW |
| 47 | Air quality controller | VOC Input 9 | 2 Bytes | 9.8 parts/million (ppm) | CW |
| 47 | Air quality controller | Humidity Input 4 | 2 Bytes | 9.7 humidity (%) | CW |
| 48 | Air quality controller | CO2 Input 10 | 2 Bytes | 9.8 parts/million (ppm) | CW |
| 48 | Air quality controller | VOC (IAQ Index) Input 10 | 2 Bytes | DPT.7 | CW |
| 48 | Air quality controller | VOC Input 10 | 2 Bytes | 9.8 parts/million (ppm) | CW |
| 48 | Air quality controller | Humidity Input 5 | 2 Bytes | 9.7 humidity (%) | CW |
| 51 | Air quality controller | Lock controller | 1 Bit | 1.3 enable | CW |
| 52 | Air quality controller | Output control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 53 | Air quality controller | Output level 1 | 1 Bit | 1.1 switch | CRT |
| 53 | Air quality controller | Output Bit 0 | 1 Bit | 1.2 boolean | CRT |
| 54 | Air quality controller | Output level 2 | 1 Bit | 1.1 switch | CRT |
| 54 | Air quality controller | Output Bit 1 | 1 Bit | 1.2 boolean | CRT |
| 55 | Air quality controller | Output level 3 | 1 Bit | 1.1 switch | CRT |
| 55 | Air quality controller | Output Bit 2 | 1 Bit | 1.2 boolean | CRT |
| 56 | Air quality controller | Output level 4 | 1 Bit | 1.1 switch | CRT |
| 57 | Day / Night | Day = 1 / Night = 0 | 1 Bit | 1.24 day/night | CWTU |
| 57 | Day / Night | Night = 1 / Day = 0 | 1 Bit | 1.24 day/night | CWTU |
| 58 | Air quality controller | Override level | 1 Byte | 5.5 ratio (0..255) | CW |
| 58 | Air quality controller | Override control value | 1 Byte | 5.1 percentage (0..100%) | CW |
| 61 | Temperature controller | Preset setpoint | 2 Bytes | 9.1 temperature (°C) | CW |
| 62 | Temperature controller | Preset Comfort setpoint | 2 Bytes | 9.1 temperature (°C) | CW |
| 62 | Temperature controller | Combination object: Preset setpoint | 8 Bytes | 275.100 Temperature setpoint setting for 4 HVAC Modes | CW |
| 62 | Temperature controller | Preset (Basic) Comfort setpoint | 2 Bytes | 9.1 temperature (°C) | CW |
| 62 | Temperature controller | (Basic) Comfort setpoint | 2 Bytes | 9.1 temperature (°C) | CW |
| 62 | Temperature controller | Combination object (Heating): Preset setpoint | 8 Bytes | 275.100 Temperature setpoint setting for 4 HVAC Modes | CW |
| 63 | Temperature controller | Preset Standby setpoint | 2 Bytes | 9.1 temperature (°C) | CW |
| 64 | Temperature controller | Preset Night setpoint | 2 Bytes | 9.1 temperature (°C) | CW |
| 65 | Temperature controller | Preset Frost protection setpoint | 2 Bytes | 9.1 temperature (°C) | CW |
| 65 | Temperature controller | Preset Heat protection setpoint | 2 Bytes | 9.1 temperature (°C) | CW |
| 66 | Temperature controller | Combination object (Cooling): Preset setpoint | 8 Bytes | 275.100 Temperature setpoint setting for 4 HVAC Modes | CW |
| 67 | Temperature controller | Send current setpoint | 2 Bytes | 9.1 temperature (°C) | CRT |
| 68 | Temperature controller | Manual setpoint shift (2Byte) | 2 Bytes | 9.2 temperature difference (K) | CW |
| 69 | Temperature controller | Manual setpoint shift (1=+ / 0=-) | 1 Bit | 1.7 step | CW |
| 69 | Temperature controller | Manual setpoint shift (1Byte) | 1 Byte | 6.10 counter pulses (-128..127) | CW |
| 70 | Temperature controller | Send status setpoint shift | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 71 | Temperature controller | Control value Heating: Send control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 71 | Temperature controller | Control value Heating: Send control value | 1 Bit | 1.1 switch | CRT |
| 71 | Temperature controller | Control value Heating/Cooling: Send control value | 1 Bit | 1.1 switch | CRT |
| 72 | Temperature controller | Control value Cooling: Send control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 72 | Temperature controller | Control value Cooling: Send control value | 1 Bit | 1.1 switch | CRT |
| 73 | Temperature controller | Control value Heating: Send status | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 73 | Temperature controller | Control value Heating/Cooling: Send status | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 74 | Temperature controller | Control value Cooling: Send status | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 75 | Temperature controller | Additional level: Send control value Heating | 1 Bit | 1.1 switch | CT |
| 76 | Temperature controller | Mode selection | 1 Byte | 20.102 HVAC mode | CW |
| 77 | Temperature controller | Comfort operating mode: Comfort extension | 1 Bit | 1.10 start/stop | CW |
| 78 | Temperature controller | Comfort mode | 1 Bit | 1.1 switch | CW |
| 79 | Temperature controller | Night mode | 1 Bit | 1.1 switch | CW |
| 80 | Temperature controller | Frost protection mode | 1 Bit | 1.1 switch | CW |
| 80 | Temperature controller | Heat protection mode | 1 Bit | 1.1 switch | CW |
| 80 | Temperature controller | Frost/Heat protection mode | 1 Bit | 1.1 switch | CW |
| 81 | Temperature controller | DPT_HVAC Status: Send controller status | 1 Byte | CRT | |
| 81 | Temperature controller | DPT_HVAC Mode: Send controller status | 1 Byte | 20.102 HVAC mode | CRT |
| 82 | Temperature controller | DPT_HVAC Status: Send controller status | 1 Byte | CRT | |
| 82 | Temperature controller | DPT_HVAC Mode: Send controller status | 1 Byte | 20.102 HVAC mode | CRT |
| 82 | Temperature controller | RHCC Status: Send controller status | 2 Bytes | 22.101 RHCC status | CRT |
| 82 | Temperature controller | DPT_RTC combined status: Send controller status | 2 Bytes | 22.103 combined status RTC | CRT |
| 82 | Temperature controller | DPT_RTSM combined status: Send controller status | 1 Byte | 21.107 combined status RTSM | CRT |
| 83 | Temperature controller | Send Frost alarm | 1 Bit | 1.5 alarm | CRT |
| 84 | Temperature controller | Send Heat alarm | 1 Bit | 1.5 alarm | CRT |
| 85 | Temperature controller | Receive flow temperature Heating | 2 Bytes | 9.1 temperature (°C) | CWT |
| 86 | Temperature controller | Receive surface temperature Cooling | 2 Bytes | 9.1 temperature (°C) | CWT |
| 86 | Temperature controller | Receive dew point alarm | 1 Bit | 1.5 alarm | CWT |
| 87 | Temperature controller | Diagnosis status | 14 Bytes | 16.1 Character String (ISO 8859-1) | CRT |
| 88 | Temperature controller | Window contact: 0=closed / 1=open | 1 Bit | 1.19 window/door | CWTU |
| 88 | Temperature controller | Window contact: 1=closed / 0=open | 1 Bit | 1.1 switch | CWTU |
| 89 | Temperature controller | Lock object Heating: Lock control value | 1 Bit | 1.3 enable | CRWTU |
| 90 | Temperature controller | Lock object Cooling: Lock control value | 1 Bit | 1.3 enable | CRWTU |
| 93 | Temperature controller | Switchover: 1=Heating 0=Cooling | 1 Bit | 1.100 cooling/heating | CW |
| 94 | Temperature controller | Status: 1=Heating 0=Cooling | 1 Bit | 1.100 cooling/heating | CRT |
| 95 | Temperature controller | Send Heating request | 1 Bit | 1.1 switch | CRT |
| 96 | Temperature controller | Send Cooling request | 1 Bit | 1.1 switch | CRT |
| 97 | Outside temperature | Receive measured value/reference value | 2 Bytes | 9.1 temperature (°C) | CW |
| 100 | Operating | Output | 1 Bit | 1.11 state | CRT |
Parameters (197)
| Parameter | Type | Default |
|---|---|---|
| Startup time | unsignedInt 2…240 | 2 |
| Send "Operation" cyclically | list | not active |
| Value for Day/Night | list | Day = 1 / Night = 0 |
| Day/Night object after bus power return | list | request |
| Language diagnosis text | list | German |
| CO2 measurement | list | active |
| VOC measurement | list | active |
| Temperature measurement | list | active |
| Relative humidity measurement | list | active |
| Send measured value on change | list | not active |
| Send measured value on change of | float 10…500 | 20 |
| Send measured value cyclically | list | not active |
| Messages | list | not active |
| Upper message value | float 400…2000 | 1500 |
| Lower message value | float 400…2000 | 500 |
| Calibration value for internal sensor | float -500…500 | 0 |
| Sensor internal/external | list | 100 % internal |
| Measured value output in | list | ppm |
| Send actual temperature cyclically | list | not active |
| Upper message value | float 100…5000 | 2000 |
| Lower message value | float 100…5000 | 1000 |
| Send measured value on change of | float 0.1…2 | 0.1 |
| Upper message value | float 20…45 | 28 |
| Lower message value | float 3…30 | 18 |
| Calibration value for internal sensor | float -10…10 | 0 |
| Send measured value on change of | float 1…10 | 1 |
| Upper message value | float 25…100 | 70 |
| Lower message value | float 0…75 | 30 |
| Calibration value for internal sensor | float -20…20 | 0 |
| Air quality traffic light | list | Step output |
| Sensor for Air quality traffic light | list | CO2 |
| Hysteresis in | list | percent |
| Hysteresis | list | 5% |
| Hysteresis | unsignedInt 10…500 | 100 |
| Colour for level 1 | color | #00FF00 |
| Colour for level 2 | color | #FFFF00 |
| Colour for level 3 | color | #FF8000 |
| Colour for level 4 | color | #FF0000 |
| Scene number for level 1 | list | 1 |
| Scene number for level 2 | list | 2 |
| Scene number for level 3 | list | 3 |
| Scene number for level 4 | list | 4 |
| Threshold value 1 (level 1 -> level 2) | unsignedInt 0…2000 | 800 |
| Threshold value 2 (level 2 -> level 3) | unsignedInt 0…2000 | 1200 |
| Threshold value 3 (level 3 -> level 4) | unsignedInt 0…2000 | 1700 |
| Sending condition of output | list | not active |
| Send cyclically every… | list | 60 min |
| Activate air quality controller as | list | Step controller Bit coded |
| Controller actual value | list | CO2 |
| Air quality control with humidity increase by… | list | not active |
| Threshold for exceeding the air humidity | list | 75% |
| Send setpoint/output cyclically | list | not active |
| Day/Night switchover | list | active |
| Setpoint valid | list | for Day (Night deactivated) |
| Setpoint for "Day" | unsignedInt 400…2000 | 600 |
| Minimum control value for "Day" | list | 0% |
| Maximum control value for "Day" | list | 100% |
| Setpoint for "Night" | unsignedInt 400…2000 | 700 |
| Minimum control value for "Night" | list | 0% |
| Maximum control value for "Night" | list | 30% |
| Minimum level for "Day" | list | Level 0 |
| Maximum level for "Day" | list | Level 4 |
| Minimum level for "Night" | list | Level 0 |
| Maximum level for "Night" | list | Level 2 |
| Minimum level | list | Level 0 |
| Maximum level | list | Level 4 |
| Threshold level 1 | unsignedInt 400…2000 | 600 |
| Threshold level 2 | unsignedInt 400…2000 | 800 |
| Threshold level 3 | unsignedInt 400…2000 | 1000 |
| Threshold level 4 | unsignedInt 400…2000 | 1200 |
| Hysteresis | unsignedInt 10…500 | 50 |
| Hysteresis | list | 10% |
| Control value for "Day" (level 2) | list | 50% |
| Control value for "Day" (level 3) | list | 75% |
| Control value for "Day" (level 1) | list | 25% |
| Control value for "Day" (level 4) | list | 100% |
| Control value (level 1) | list | 25% |
| Control value (level 2) | list | 50% |
| Control value (level 3) | list | 75% |
| Control value (level 4) | list | 100% |
| Control value for "Night" (level 1) | list | 10% |
| Control value for "Night" (level 2) | list | 30% |
| Control value for "Night" (level 3) | list | 50% |
| Control value for "Night" (level 4) | list | 70% |
| Proportional value | unsignedInt 100…2000 | 1000 |
| Reset time | list | 15 min |
| Behavior at lock | list | not active |
| Value at lock | list | 0% |
| Level at lock | list | Level 1 |
| Operating mode | list | not active |
| Priority | list | Frost(Heat protection)/Comfort/Night/Standby |
| Setpoints for Standby/Night | list | depending on setpoint Comfort (Basic) |
| Setpoint Comfort (Basic) | float 7…35 | 21 |
| Setpoint Standby | float 7…35 | 19 |
| Setpoint Night | float 7…35 | 18 |
| Standby reduction | list | 2,0 K |
| Night reduction | list | 3,0 K |
| Setpoint Frost protection | float 3…12 | 7 |
| Separate objects for setpoints Comfort/Standby/Night/Frost protection | list | not active |
| Maximum setpoint shift | float 0…10 | 3 |
| Setpoint shift via 1Bit/1Byte object | list | 1Bit |
| Step width | list | 0,5 K |
| Status setpoint shift | list | not active |
| Setpoint shift applies to | list | Comfort |
| Action if shift during Night/Standby | list | no action |
| Delete setpoint shift after change of operating mode | list | not active |
| Delete setpoint shift after new absolute setpoint | list | active |
| Reset setpoints to parameterization after operating mode change | list | active |
| Reset basic setpoint to configured value after change of operation mode | list | active |
| Delete setpoint shift after new basic setpoint | list | active |
| Send setpoint changes | list | active |
| Send current setpoint cyclically | list | not active |
| Comfort extention with time | list | not active |
| Comfort extention time | list | not active |
| Operating mode after reset | list | Comfort with configured setpoint |
| Operating mode after reprogramming | list | Comfort |
| HVAC status object | list | HVAC Mode (DPT 20.102) |
| Additional HVAC Status object | list | not active |
| Send HVAC Status object cyclically | list | not active |
| Lock object: Control value Heating | list | not active |
| Object for Heating request | list | not active |
| Flow temperature | list | not active |
| Limit flow temperature to | unsignedInt 10…60 | 40 |
| Setpoint Comfort (Basic) | float 7…35 | 23 |
| Setpoint Standby | float 7…35 | 24 |
| Setpoint Night | float 7…35 | 25 |
| Standby increase | list | 2,0 K |
| Night increase | list | 3,0 K |
| Setpoint Heat protection | float 24…40 | 35 |
| Separate objects for setpoints of Comfort/Standby/Night Heating protection | list | not active |
| Lock object: Control value Cooling | list | not active |
| Object for Cooling request | list | not active |
| Reference via outdoor temperature | list | not active |
| Reference variable minimum | unsignedInt 10…60 | 28 |
| Reference variable maximum | unsignedInt 10…60 | 38 |
| Setpoint change at maximum reference variable | float 1…10 | 10 |
| Limit temperature of cooling medium | list | not active |
| Offset to dew point temperature | list | 0 K |
| (Basic) Comfort setpoint | float 7…35 | 21 |
| Switchover Heating/Cooling | list | automatically |
| Dead zone between Heating and Cooling | list | 2,0 K |
| Dead zone between Heating and Cooling | list | 0 K |
| Separate objects for setpoints Comfort/Standby/Night/Frost-/Heat protection | list | not active |
| Operating mode after reprogramming | list | Comfort (Cooling) |
| Alarms | list | not active |
| Frost alarm if value less | unsignedInt 3…10 | 7 |
| Heat alarm if value greater | unsignedInt 25…40 | 35 |
| Window contact | list | not active |
| State of window | list | 0=closed / 1=open (standard DPT) |
| Delay time | unsignedInt 0…240 | 5 |
| Action when opening the window | list | force Frost/Heat protection |
| Action when closing the window | list | HVAC Modus before locking |
| Release time | list | 12 h |
| Control value | list | PI control continuous |
| Direction of controller | list | normal |
| Maximum value of control value | list | 100% |
| Heating system | list | Underfloor Heating (4K / 150min) |
| Proportional range | list | 4 K |
| Reset time | list | 150 min |
| PWM cycle | list | 10 min |
| Switching hysteresis | list | 2,0 K |
| Send control value cyclically | list | 5 min |
| Additional level | list | not active |
| Direction of action with rising temperature | list | normal |
| Control value | list | 2-step control (switching) |
| Distance | list | 2,0 K |
| Operating mode | list | PI control continuous |
| Cooling system | list | Cooling ceiling (4K / 150min) |
| System | list | 2-pipe / 1 circuit (Heating or Cooling) |
| Setpoint | unsignedInt 400…2000 | 600 |
| Minimum control value | list | 0% |
| Maximum control value | list | 100% |
| Send measured value on change of | unsignedInt 1…50 | 5 |
| Upper message value | unsignedInt 0…500 | 200 |
| Lower message value | unsignedInt 0…500 | 50 |
| Hysteresis | unsignedInt 0…50 | 5 |
| Traffic light with | list | 3 levels |
| Hysteresis in | list | IAQ |
| Proportional value | unsignedInt 10…250 | 100 |
| Threshold level 1 | unsignedInt 50…500 | 80 |
| Threshold level 2 | unsignedInt 50…500 | 160 |
| Threshold level 3 | unsignedInt 50…500 | 240 |
| Threshold level 4 | unsignedInt 50…500 | 320 |
| Setpoint for "Day" | unsignedInt 0…500 | 80 |
| Setpoint | unsignedInt 0…500 | 80 |
| Setpoint for "Night" | unsignedInt 0…500 | 100 |
| Number of external room sensors | list | not active |
| Threshold value 1 (level 1 -> level 2) | unsignedInt 0…500 | 100 |
| Threshold value 2 (level 2 -> level 3) | unsignedInt 0…500 | 250 |
| Threshold value 3 (level 3 -> level 4) | unsignedInt 0…500 | 400 |
| Air quality traffic light | list | not active |
| Air quality controller | list | not active |
| Follow-up time after falling below | unsignedInt 1…60 | 30 |
| IAQ Index description | picture | |
| Reset the preset setpoint to parameter settings via Object 37 at the next Day/Night changeover | list | active |
| Scene number for level 3 | list | 4 |
| Colour for level 3 | color | #FF0000 |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Air Quality Sensor with CO2 and VOC sensor 1.2 latest | $0146 | 1EDD | 2026-11-25 | 261 KB | Download |
About this file
This is the official ETS product database for the MDT technologies GmbH SCN-CO2MGS.02 CO2 / VOC Combi Sensor 55 (SCN-CO2MGS.02), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from MDT technologies GmbH
- BE-BZS86.01 Central Operation Unit Smart 86 BE-BZS86.01
- BE-GBZx.01 Glass Central Operation Unit Smart BE-GBZx.01
- SCN-CO2M601x.02 CO2 / VOC Combi Sensor 60 CH SCN-CO2M601x.02
- SCN-KP360K3.03 Combi-Presence Detector 360° with room climate sensors SCN-KP360K3.03
- Glass Central Operation Unit with LCD SCN-LCDGx.01
- Analog I/O 2fold, flush mounted AIO-0210V.01
- Analog I/O 4fold, MDRC AIO-0410V.01
- AKD-0103.01 Dimming actuator 1-f, 4TE, 230VAC,600W AKD-0103.01
- AKD-0201.01 Dimming actuator 2-f, 4TE, 230VAC,250W AKD-0201.01
- AKD-0201.02 Dimming Actuator 2-fold AKD-0201.02
- AKD-0203.01 Dimming actuator 2-f, 8TE, 230VAC,600W AKD-0203.01
- AKD-0224V.01 LED Controller 2 channel AKD-0224V.01