SCN-CO2M601x.02 CO2 / VOC Combi Sensor 60 CH SCN-CO2M601x.02

MDT technologies GmbH · Order number SCN-CO2M601x.02 · Controller › Air quality/CO2 sensor

Download .knxprod Air Quality Sensor with CO2 and VOC sensor 1.2 · 261 KB

Product

ManufacturerMDT technologies GmbH
Product nameSCN-CO2M601x.02 CO2 / VOC Combi Sensor 60 CH
Order numberSCN-CO2M601x.02
HardwareLuftqualitätssensor mit CO2- und VOC-Sensor
MediumTwisted Pair
Bus current (mA)10
Rail mountedNo
RegistrationRegistered · 2026-02-16
Languagesde-DE, en-US, es-ES, fr-FR, it-IT
Catalog entryM-0083_H-271-1_HP-0146-12-1EDD_CI-SCN.2DCO2M601x.2E02-1
Fingerprint1EDD
SHA-256b73cb2692f7555751c291986cb2ea7247bceaef94e6c8da1f7b6681ee2bd6c1f
First seen2026-11-25
Markets69 markets

Application program: Air Quality Sensor with CO2 and VOC sensor 1.2

Application number$0146
Version1.2
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version5.0
Parameters244
Group objects137
Group objects (137)
NoNameFunctionSizeDPTFlags
1CO2 measurementSend measured value2 Bytes9.8 parts/million (ppm)CRT
2CO2 measurementExternal sensor input2 Bytes9.8 parts/million (ppm)CWTU
3CO2 measurementMaximum value exceeded1 Bit1.5 alarmCRT
4CO2 measurementMinimum value fallen below1 Bit1.5 alarmCRT
5CO2 measurementError external sensor1 Bit1.5 alarmCRT
8VOC measurementSend measured value2 Bytes9.8 parts/million (ppm)CRT
8VOC measurementSend measured value2 BytesDPT.7CRT
9VOC measurementExternal sensor input2 Bytes9.8 parts/million (ppm)CWTU
9VOC measurementExternal sensor input2 BytesDPT.7CWTU
10VOC measurementMaximum value exceeded1 Bit1.5 alarmCRT
11VOC measurementMinimum value fallen below1 Bit1.5 alarmCRT
12VOC measurementError external sensor1 Bit1.5 alarmCRT
15Temperature measurementSend measured value2 Bytes9.1 temperature (°C)CRT
16Temperature measurementExternal sensor input2 Bytes9.1 temperature (°C)CWTU
17Temperature measurementMaximum value exceeded1 Bit1.5 alarmCRT
18Temperature measurementMinimum value fallen below1 Bit1.5 alarmCRT
19Temperature measurementError external sensor1 Bit1.5 alarmCRT
22Relative humidity measurementSend measured value2 Bytes9.7 humidity (%)CRT
23Relative humidity measurementExternal sensor input2 Bytes9.7 humidity (%)CWTU
24Relative humidity measurementMaximum value exceeded1 Bit1.5 alarmCRT
25Relative humidity measurementMinimum value fallen below1 Bit1.5 alarmCRT
26Relative humidity measurementError external sensor1 Bit1.5 alarmCRT
29Air quality traffic lightOutput level 11 Bit1.1 switchCRT
30Air quality traffic lightOutput level 21 Bit1.1 switchCRT
31Air quality traffic lightOutput level 31 Bit1.1 switchCRT
32Air quality traffic lightOutput level 41 Bit1.1 switchCRT
32Air quality traffic lightOutput level 31 Bit1.1 switchCRT
33Air quality traffic lightOutput RGB3 Bytes232.600 RGB value 3x(0..255)CRT
33Air quality traffic lightOutput HSV3 Bytes232.600 RGB value 3x(0..255)CRT
34Air quality traffic lightOutput Scene1 Byte17.1 scene numberCRT
37Air quality controllerPreset setpoint2 Bytes9.8 parts/million (ppm)CW
37Air quality controllerPreset setpoint2 BytesDPT.7CW
38Air quality controllerActual setpoint2 Bytes9.8 parts/million (ppm)CRT
38Air quality controllerActual setpoint2 BytesDPT.7CRT
39Air quality controllerCO2 Input 12 Bytes9.8 parts/million (ppm)CW
39Air quality controllerVOC (IAQ Index) Input 12 BytesDPT.7CW
39Air quality controllerVOC Input 12 Bytes9.8 parts/million (ppm)CW
40Air quality controllerCO2 Input 22 Bytes9.8 parts/million (ppm)CW
40Air quality controllerVOC (IAQ Index) Input 22 BytesDPT.7CW
40Air quality controllerVOC Input 22 Bytes9.8 parts/million (ppm)CW
41Air quality controllerCO2 Input 32 Bytes9.8 parts/million (ppm)CW
41Air quality controllerVOC (IAQ Index) Input 32 BytesDPT.7CW
41Air quality controllerVOC Input 32 Bytes9.8 parts/million (ppm)CW
42Air quality controllerCO2 Input 42 Bytes9.8 parts/million (ppm)CW
42Air quality controllerVOC (IAQ Index) Input 42 BytesDPT.7CW
42Air quality controllerVOC Input 42 Bytes9.8 parts/million (ppm)CW
43Air quality controllerCO2 Input 52 Bytes9.8 parts/million (ppm)CW
43Air quality controllerVOC (IAQ Index) Input 52 BytesDPT.7CW
43Air quality controllerVOC Input 52 Bytes9.8 parts/million (ppm)CW
44Air quality controllerCO2 Input 62 Bytes9.8 parts/million (ppm)CW
44Air quality controllerVOC (IAQ Index) Input 62 BytesDPT.7CW
44Air quality controllerVOC Input 62 Bytes9.8 parts/million (ppm)CW
44Air quality controllerHumidity Input 12 Bytes9.7 humidity (%)CW
45Air quality controllerCO2 Input 72 Bytes9.8 parts/million (ppm)CW
45Air quality controllerVOC (IAQ Index) Input 72 BytesDPT.7CW
45Air quality controllerVOC Input 72 Bytes9.8 parts/million (ppm)CW
45Air quality controllerHumidity Input 22 Bytes9.7 humidity (%)CW
46Air quality controllerCO2 Input 82 Bytes9.8 parts/million (ppm)CW
46Air quality controllerVOC (IAQ Index) Input 82 BytesDPT.7CW
46Air quality controllerVOC Input 82 Bytes9.8 parts/million (ppm)CW
46Air quality controllerHumidity Input 32 Bytes9.7 humidity (%)CW
47Air quality controllerCO2 Input 92 Bytes9.8 parts/million (ppm)CW
47Air quality controllerVOC (IAQ Index) Input 92 BytesDPT.7CW
47Air quality controllerVOC Input 92 Bytes9.8 parts/million (ppm)CW
47Air quality controllerHumidity Input 42 Bytes9.7 humidity (%)CW
48Air quality controllerCO2 Input 102 Bytes9.8 parts/million (ppm)CW
48Air quality controllerVOC (IAQ Index) Input 102 BytesDPT.7CW
48Air quality controllerVOC Input 102 Bytes9.8 parts/million (ppm)CW
48Air quality controllerHumidity Input 52 Bytes9.7 humidity (%)CW
51Air quality controllerLock controller1 Bit1.3 enableCW
52Air quality controllerOutput control value1 Byte5.1 percentage (0..100%)CRT
53Air quality controllerOutput level 11 Bit1.1 switchCRT
53Air quality controllerOutput Bit 01 Bit1.2 booleanCRT
54Air quality controllerOutput level 21 Bit1.1 switchCRT
54Air quality controllerOutput Bit 11 Bit1.2 booleanCRT
55Air quality controllerOutput level 31 Bit1.1 switchCRT
55Air quality controllerOutput Bit 21 Bit1.2 booleanCRT
56Air quality controllerOutput level 41 Bit1.1 switchCRT
57Day / NightDay = 1 / Night = 01 Bit1.24 day/nightCWTU
57Day / NightNight = 1 / Day = 01 Bit1.24 day/nightCWTU
58Air quality controllerOverride level1 Byte5.5 ratio (0..255)CW
58Air quality controllerOverride control value1 Byte5.1 percentage (0..100%)CW
61Temperature controllerPreset setpoint2 Bytes9.1 temperature (°C)CW
62Temperature controllerPreset Comfort setpoint2 Bytes9.1 temperature (°C)CW
62Temperature controllerCombination object: Preset setpoint 8 Bytes275.100 Temperature setpoint setting for 4 HVAC ModesCW
62Temperature controllerPreset (Basic) Comfort setpoint2 Bytes9.1 temperature (°C)CW
62Temperature controller(Basic) Comfort setpoint2 Bytes9.1 temperature (°C)CW
62Temperature controllerCombination object (Heating): Preset setpoint 8 Bytes275.100 Temperature setpoint setting for 4 HVAC ModesCW
63Temperature controllerPreset Standby setpoint2 Bytes9.1 temperature (°C)CW
64Temperature controllerPreset Night setpoint2 Bytes9.1 temperature (°C)CW
65Temperature controllerPreset Frost protection setpoint2 Bytes9.1 temperature (°C)CW
65Temperature controllerPreset Heat protection setpoint2 Bytes9.1 temperature (°C)CW
66Temperature controllerCombination object (Cooling): Preset setpoint8 Bytes275.100 Temperature setpoint setting for 4 HVAC ModesCW
67Temperature controllerSend current setpoint2 Bytes9.1 temperature (°C)CRT
68Temperature controllerManual setpoint shift (2Byte)2 Bytes9.2 temperature difference (K)CW
69Temperature controllerManual setpoint shift (1=+ / 0=-)1 Bit1.7 stepCW
69Temperature controllerManual setpoint shift (1Byte)1 Byte6.10 counter pulses (-128..127)CW
70Temperature controllerSend status setpoint shift2 Bytes9.2 temperature difference (K)CRT
71Temperature controllerControl value Heating: Send control value1 Byte5.1 percentage (0..100%)CRT
71Temperature controllerControl value Heating: Send control value1 Bit1.1 switchCRT
71Temperature controllerControl value Heating/Cooling: Send control value1 Bit1.1 switchCRT
72Temperature controllerControl value Cooling: Send control value1 Byte5.1 percentage (0..100%)CRT
72Temperature controllerControl value Cooling: Send control value1 Bit1.1 switchCRT
73Temperature controllerControl value Heating: Send status1 Byte5.1 percentage (0..100%)CRT
73Temperature controllerControl value Heating/Cooling: Send status1 Byte5.1 percentage (0..100%)CRT
74Temperature controllerControl value Cooling: Send status1 Byte5.1 percentage (0..100%)CRT
75Temperature controllerAdditional level: Send control value Heating1 Bit1.1 switchCT
76Temperature controllerMode selection1 Byte20.102 HVAC modeCW
77Temperature controllerComfort operating mode: Comfort extension1 Bit1.10 start/stopCW
78Temperature controllerComfort mode1 Bit1.1 switchCW
79Temperature controllerNight mode1 Bit1.1 switchCW
80Temperature controllerFrost protection mode1 Bit1.1 switchCW
80Temperature controllerHeat protection mode1 Bit1.1 switchCW
80Temperature controllerFrost/Heat protection mode1 Bit1.1 switchCW
81Temperature controllerDPT_HVAC Status: Send controller status1 ByteCRT
81Temperature controllerDPT_HVAC Mode: Send controller status1 Byte20.102 HVAC modeCRT
82Temperature controllerDPT_HVAC Status: Send controller status1 ByteCRT
82Temperature controllerDPT_HVAC Mode: Send controller status1 Byte20.102 HVAC modeCRT
82Temperature controllerRHCC Status: Send controller status2 Bytes22.101 RHCC statusCRT
82Temperature controllerDPT_RTC combined status: Send controller status2 Bytes22.103 combined status RTCCRT
82Temperature controllerDPT_RTSM combined status: Send controller status1 Byte21.107 combined status RTSMCRT
83Temperature controllerSend Frost alarm1 Bit1.5 alarmCRT
84Temperature controllerSend Heat alarm1 Bit1.5 alarmCRT
85Temperature controllerReceive flow temperature Heating2 Bytes9.1 temperature (°C)CWT
86Temperature controllerReceive surface temperature Cooling2 Bytes9.1 temperature (°C)CWT
86Temperature controllerReceive dew point alarm1 Bit1.5 alarmCWT
87Temperature controllerDiagnosis status14 Bytes16.1 Character String (ISO 8859-1)CRT
88Temperature controllerWindow contact: 0=closed / 1=open1 Bit1.19 window/doorCWTU
88Temperature controllerWindow contact: 1=closed / 0=open1 Bit1.1 switchCWTU
89Temperature controllerLock object Heating: Lock control value1 Bit1.3 enableCRWTU
90Temperature controllerLock object Cooling: Lock control value1 Bit1.3 enableCRWTU
93Temperature controllerSwitchover: 1=Heating 0=Cooling1 Bit1.100 cooling/heatingCW
94Temperature controllerStatus: 1=Heating 0=Cooling1 Bit1.100 cooling/heatingCRT
95Temperature controllerSend Heating request1 Bit1.1 switchCRT
96Temperature controllerSend Cooling request1 Bit1.1 switchCRT
97Outside temperatureReceive measured value/reference value2 Bytes9.1 temperature (°C)CW
100OperatingOutput1 Bit1.11 stateCRT
Parameters (197)
ParameterTypeDefault
Startup timeunsignedInt 2…2402
Send "Operation" cyclicallylistnot active
Value for Day/NightlistDay = 1 / Night = 0
Day/Night object after bus power returnlistrequest
Language diagnosis textlistGerman
CO2 measurementlistactive
VOC measurementlistactive
Temperature measurementlistactive
Relative humidity measurementlistactive
Send measured value on changelistnot active
Send measured value on change offloat 10…50020
Send measured value cyclicallylistnot active
Messageslistnot active
Upper message valuefloat 400…20001500
Lower message valuefloat 400…2000500
Calibration value for internal sensorfloat -500…5000
Sensor internal/externallist100 % internal
Measured value output inlistppm
Send actual temperature cyclicallylistnot active
Upper message valuefloat 100…50002000
Lower message valuefloat 100…50001000
Send measured value on change offloat 0.1…20.1
Upper message valuefloat 20…4528
Lower message valuefloat 3…3018
Calibration value for internal sensorfloat -10…100
Send measured value on change offloat 1…101
Upper message valuefloat 25…10070
Lower message valuefloat 0…7530
Calibration value for internal sensorfloat -20…200
Air quality traffic lightlistStep output
Sensor for Air quality traffic lightlistCO2
Hysteresis inlistpercent
Hysteresislist5%
HysteresisunsignedInt 10…500100
Colour for level 1color#00FF00
Colour for level 2color#FFFF00
Colour for level 3color#FF8000
Colour for level 4color#FF0000
Scene number for level 1list1
Scene number for level 2list2
Scene number for level 3list3
Scene number for level 4list4
Threshold value 1 (level 1 -> level 2)unsignedInt 0…2000800
Threshold value 2 (level 2 -> level 3)unsignedInt 0…20001200
Threshold value 3 (level 3 -> level 4)unsignedInt 0…20001700
Sending condition of outputlistnot active
Send cyclically every…list60 min
Activate air quality controller aslistStep controller Bit coded
Controller actual valuelistCO2
Air quality control with humidity increase by…listnot active
Threshold for exceeding the air humiditylist75%
Send setpoint/output cyclicallylistnot active
Day/Night switchoverlistactive
Setpoint validlistfor Day (Night deactivated)
Setpoint for "Day"unsignedInt 400…2000600
Minimum control value for "Day"list0%
Maximum control value for "Day"list100%
Setpoint for "Night"unsignedInt 400…2000700
Minimum control value for "Night"list0%
Maximum control value for "Night"list30%
Minimum level for "Day"listLevel 0
Maximum level for "Day"listLevel 4
Minimum level for "Night"listLevel 0
Maximum level for "Night"listLevel 2
Minimum levellistLevel 0
Maximum levellistLevel 4
Threshold level 1unsignedInt 400…2000600
Threshold level 2unsignedInt 400…2000800
Threshold level 3unsignedInt 400…20001000
Threshold level 4unsignedInt 400…20001200
HysteresisunsignedInt 10…50050
Hysteresislist10%
Control value for "Day" (level 2)list50%
Control value for "Day" (level 3)list75%
Control value for "Day" (level 1)list25%
Control value for "Day" (level 4)list100%
Control value (level 1)list25%
Control value (level 2)list50%
Control value (level 3)list75%
Control value (level 4)list100%
Control value for "Night" (level 1)list10%
Control value for "Night" (level 2)list30%
Control value for "Night" (level 3)list50%
Control value for "Night" (level 4)list70%
Proportional valueunsignedInt 100…20001000
Reset timelist15 min
Behavior at locklistnot active
Value at locklist0%
Level at locklistLevel 1
Operating modelistnot active
PrioritylistFrost(Heat protection)/Comfort/Night/Standby
Setpoints for Standby/Nightlistdepending on setpoint Comfort (Basic)
Setpoint Comfort (Basic)float 7…3521
Setpoint Standbyfloat 7…3519
Setpoint Nightfloat 7…3518
Standby reductionlist2,0 K
Night reductionlist3,0 K
Setpoint Frost protectionfloat 3…127
Separate objects for setpoints Comfort/Standby/Night/Frost protectionlistnot active
Maximum setpoint shiftfloat 0…103
Setpoint shift via 1Bit/1Byte objectlist1Bit
Step widthlist0,5 K
Status setpoint shiftlistnot active
Setpoint shift applies tolistComfort
Action if shift during Night/Standbylistno action
Delete setpoint shift after change of operating modelistnot active
Delete setpoint shift after new absolute setpointlistactive
Reset setpoints to parameterization after operating mode changelistactive
Reset basic setpoint to configured value after change of operation modelistactive
Delete setpoint shift after new basic setpointlistactive
Send setpoint changeslistactive
Send current setpoint cyclicallylistnot active
Comfort extention with timelistnot active
Comfort extention timelistnot active
Operating mode after resetlistComfort with configured setpoint
Operating mode after reprogramminglistComfort
HVAC status objectlistHVAC Mode (DPT 20.102)
Additional HVAC Status objectlistnot active
Send HVAC Status object cyclicallylistnot active
Lock object: Control value Heatinglistnot active
Object for Heating requestlistnot active
Flow temperaturelistnot active
Limit flow temperature tounsignedInt 10…6040
Setpoint Comfort (Basic)float 7…3523
Setpoint Standbyfloat 7…3524
Setpoint Nightfloat 7…3525
Standby increaselist2,0 K
Night increaselist3,0 K
Setpoint Heat protectionfloat 24…4035
Separate objects for setpoints of Comfort/Standby/Night Heating protectionlistnot active
Lock object: Control value Coolinglistnot active
Object for Cooling requestlistnot active
Reference via outdoor temperaturelistnot active
Reference variable minimumunsignedInt 10…6028
Reference variable maximumunsignedInt 10…6038
Setpoint change at maximum reference variablefloat 1…1010
Limit temperature of cooling mediumlistnot active
Offset to dew point temperaturelist0 K
(Basic) Comfort setpointfloat 7…3521
Switchover Heating/Coolinglistautomatically
Dead zone between Heating and Coolinglist2,0 K
Dead zone between Heating and Coolinglist0 K
Separate objects for setpoints Comfort/Standby/Night/Frost-/Heat protectionlistnot active
Operating mode after reprogramminglistComfort (Cooling)
Alarmslistnot active
Frost alarm if value lessunsignedInt 3…107
Heat alarm if value greaterunsignedInt 25…4035
Window contactlistnot active
State of windowlist0=closed / 1=open (standard DPT)
Delay timeunsignedInt 0…2405
Action when opening the windowlistforce Frost/Heat protection
Action when closing the windowlistHVAC Modus before locking
Release timelist12 h
Control valuelistPI control continuous
Direction of controllerlistnormal
Maximum value of control valuelist100%
Heating systemlistUnderfloor Heating (4K / 150min)
Proportional rangelist4 K
Reset timelist150 min
PWM cyclelist10 min
Switching hysteresislist2,0 K
Send control value cyclicallylist5 min
Additional levellistnot active
Direction of action with rising temperaturelistnormal
Control valuelist2-step control (switching)
Distancelist2,0 K
Operating modelistPI control continuous
Cooling systemlistCooling ceiling (4K / 150min)
Systemlist2-pipe / 1 circuit (Heating or Cooling)
SetpointunsignedInt 400…2000600
Minimum control valuelist0%
Maximum control valuelist100%
Send measured value on change ofunsignedInt 1…505
Upper message valueunsignedInt 0…500200
Lower message valueunsignedInt 0…50050
HysteresisunsignedInt 0…505
Traffic light withlist3 levels
Hysteresis inlistIAQ
Proportional valueunsignedInt 10…250100
Threshold level 1unsignedInt 50…50080
Threshold level 2unsignedInt 50…500160
Threshold level 3unsignedInt 50…500240
Threshold level 4unsignedInt 50…500320
Setpoint for "Day"unsignedInt 0…50080
SetpointunsignedInt 0…50080
Setpoint for "Night"unsignedInt 0…500100
Number of external room sensorslistnot active
Threshold value 1 (level 1 -> level 2)unsignedInt 0…500100
Threshold value 2 (level 2 -> level 3)unsignedInt 0…500250
Threshold value 3 (level 3 -> level 4)unsignedInt 0…500400
Air quality traffic lightlistnot active
Air quality controllerlistnot active
Follow-up time after falling belowunsignedInt 1…6030
IAQ Index descriptionpicture
Reset the preset setpoint to parameter settings via Object 37 at the next Day/Night changeoverlistactive
Scene number for level 3list4
Colour for level 3color#FF0000

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Air Quality Sensor with CO2 and VOC sensor 1.2 latest$01461EDD2026-11-25261 KBDownload

About this file

This is the official ETS product database for the MDT technologies GmbH SCN-CO2M601x.02 CO2 / VOC Combi Sensor 60 CH (SCN-CO2M601x.02), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.