Glass Central Operation Unit with LCD SCN-LCDGx.01
MDT technologies GmbH · Order number SCN-LCDGx.01 · Controller › Glass Central Operation Unit
RTC, Fan control, Switch functions
Download .knxprod Glass Central Operation Unit 1.3 · 415 KB
Product
| Manufacturer | MDT technologies GmbH |
|---|---|
| Product name | Glass Central Operation Unit with LCD |
| Order number | SCN-LCDGx.01 |
| Hardware | Glas Bedienzentrale mit LCD |
| Medium | Twisted Pair |
| Bus current (mA) | 10 |
| Rail mounted | No |
| Registration | Certified · 2014-11-04 |
| Languages | de-DE, en-US |
| Catalog entry | M-0083_H-73-0_HP-0048-13-F256_CI-SCN.2DLCDGx.2E01-1 |
| Fingerprint | F256 |
| SHA-256 | 9ddde41116ce29b9abf809d6381345a703b293e990be5b33fa5572364762885d |
| First seen | 2026-11-25 |
| Markets | 69 markets |
Application program: Glass Central Operation Unit 1.3
| Application number | $0048 |
|---|---|
| Version | 1.3 |
| Mask version | MV-0701 (7.1) |
| KNX Data Secure | No |
| Minimum ETS version | 3.0d |
| Parameters | 3960 |
| Group objects | 555 |
Group objects (555)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Actual temperature value | Transmit temperature value | 2 Bytes | 9.1 temperature (°C) | CRT |
| 1 | max. temperature | Exceeded value | 1 Bit | CRT | |
| 2 | min. temperature | Below the value | 1 Bit | CRT | |
| 3 | Frost alarm | Send alarm | 1 Bit | CRT | |
| 4 | Heat alarm | Send alarm | 1 Bit | CRT | |
| 5 | External sensor | Read external sensor | 2 Bytes | 9.1 temperature (°C) | CW |
| 6 | Setpoint comfort | Set setpoint | 2 Bytes | 9.1 temperature (°C) | CRWT |
| 7 | Manual set point value offset | Reduction / increase | 2 Bytes | 9.2 temperature difference (K) | CW |
| 8 | Control value heating | Send control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 8 | Control value heating | Send control value | 1 Bit | CRT | |
| 8 | Control value heating/cooling | Send setpoint | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 8 | Control value heating/cooling | Send setpoint | 1 Bit | CRT | |
| 9 | Control value additional heating | Send control value | 1 Bit | CRT | |
| 10 | Control value cooling | Send control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 10 | Control value cooling | Send control value | 1 Bit | CRT | |
| 10 | Requirement Cooling / Heating | 0=Cooling 1=Heating | 1 Bit | CRT | |
| 11 | Mode comfort | Switch mode | 1 Bit | 1.1 switch | CW |
| 12 | Mode night | Switch mode | 1 Bit | 1.1 switch | CW |
| 13 | Mode frost/heat protection | Switch mode | 1 Bit | 1.1 switch | CW |
| 13 | Frost protection mode | Switch mode | 1 Bit | 1.1 switch | CW |
| 13 | Heat protection mode | Switch mode | 1 Bit | 1.1 switch | CW |
| 14 | Heating disable object | Disable heating | 1 Bit | 1.3 enable | CW |
| 15 | Cooling disable object | Disable cooling | 1 Bit | 1.3 enable | CW |
| 16 | Dummy | 1 Bit | |||
| 17 | Heating request | Send request | 1 Bit | 1.1 switch | CRT |
| 18 | Cooling request | Send request | 1 Bit | 1.1 switch | CRT |
| 19 | Heating/cooling switchover | 0=Cooling 1=Heating | 1 Bit | CWT | |
| 20 | Outside temperature | Read external sensor | 2 Bytes | 9.1 temperature (°C) | CWT |
| 21 | Max memory value | Read memory | 2 Bytes | 9.1 temperature (°C) | CRT |
| 22 | Min memory value | Read memory | 2 Bytes | 9.1 temperature (°C) | CRT |
| 23 | Min/max memory reset | Reset memory | 1 Bit | 1.3 enable | CW |
| 24 | Reset setpoint value | Parameter read in | 1 Bit | 1.3 enable | CW |
| 25 | DPT_HVAC Status | Send controller status | 1 Byte | CRT | |
| 26 | Dummy | 1 Byte | |||
| 27 | Day/Night | Switching | 1 Bit | 1.1 switch | CWT |
| 28 | Error external sensor | Error message | 1 Bit | CRT | |
| 29 | Current setpoint | Send setpoint | 2 Bytes | 9.1 temperature (°C) | CRT |
| 30 | RHCC Status | Send controller status | 2 Bytes | CRT | |
| 31 | Mode selection | Select mode | 1 Byte | CW | |
| 31 | Mode selection | Select mode | 1 Byte | CRWT | |
| 32 | Manual set point value offset | Increase / Reduction (1=+/0=-) | 1 Bit | CW | |
| 33 | Flow temperature | Read external sensor | 2 Bytes | 9.1 temperature (°C) | CWT |
| 34 | Dummy | 1 Byte | |||
| 35 | Dummy | 1 Byte | |||
| 36 | Dummy | 1 Byte | |||
| 37 | Dummy | 1 Byte | |||
| 38 | Ventilation control | Block | 1 Bit | 1.3 enable | CW |
| 39 | Ventilation control | Level 1 | 1 Bit | 1.1 switch | CRT |
| 39 | Ventilation control | Bit 0 | 1 Bit | 1.2 boolean | CRT |
| 40 | Ventilation control | Level 2 | 1 Bit | 1.1 switch | CRT |
| 40 | Ventilation control | Bit 1 | 1 Bit | 1.2 boolean | CRT |
| 40 | Ventilation control | Level 1+2 | 1 Bit | 1.1 switch | CRT |
| 41 | Ventilation control | Level 3 | 1 Bit | 1.1 switch | CRT |
| 41 | Ventilation control | Bit 2 | 1 Bit | 1.2 boolean | CRT |
| 41 | Ventilation control | Level 1+2+3 | 1 Bit | 1.1 switch | CRT |
| 42 | Ventilation control | Level 4 | 1 Bit | 1.1 switch | CRT |
| 42 | Ventilation control | Level 1+2+3+4 | 1 Bit | 1.1 switch | CRT |
| 43 | Ventilation control | Status for ventilation active | 1 Bit | 1.1 switch | CRT |
| 43 | Ventilation control | 1Byte status ventilation level | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 43 | Ventilation control | 1Byte current ventilationLevel | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 44 | Ventilation control | Control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 45 | Ventilation control | Object Priority | 1 Bit | 1.1 switch | CW |
| 46 | Ventilation control | Switch Automatic | 1 Bit | 1.1 switch | CRWT |
| 46 | Ventilation control | Switch Automatic | 1 Bit | 1.1 switch | CWT |
| 47 | Ventilation control | Control levels manually | 1 Bit | CWT | |
| 47 | Ventilation control | Control levels manually | 1 Bit | CT | |
| 48 | Dummy | 1 Bit | |||
| 49 | Dummy | 1 Bit | |||
| 50 | Dummy | 1 Bit | |||
| 51 | Dummy | 1 Bit | |||
| 52 | Dummy | 1 Bit | |||
| 53 | Dummy | 1 Bit | |||
| 54 | Time | Receive status | 3 Bytes | 10.1 time of day | CWT |
| 54 | Time | Send status | 3 Bytes | 10.1 time of day | CRT |
| 55 | Date | Receive status | 3 Bytes | 11.1 date | CWT |
| 55 | Date | Send status | 3 Bytes | 11.1 date | CRT |
| 56 | Date and Time | Receive status | 8 Bytes | CWT | |
| 56 | Date and Time | Send status | 8 Bytes | CRT | |
| 57 | Message 1 | Alarm input for text message | 1 Bit | CW | |
| 58 | Message 2 | Alarm input for text message | 1 Bit | CW | |
| 59 | Message 3 | Alarm input for text message | 1 Bit | CW | |
| 60 | Message 4 | Alarm input for text message | 1 Bit | CW | |
| 61 | Message 14 Byte | Variable text message | 14 Bytes | 16.0 Character String (ASCII) | CW |
| 62 | Direct function | Switch On/Off | 1 Bit | 1.1 switch | CRT |
| 62 | Direct function | Dimming on/off | 1 Bit | 1.1 switch | CRT |
| 62 | Direct function | Shutter Down/Up | 1 Bit | 1.8 up/down | CRT |
| 62 | Direct function: left button | Switch | 1 Bit | 1.1 switch | CRT |
| 62 | Direct function: left button | send value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 62 | Direct function: left button | Short key press | 1 Bit | 1.1 switch | CRT |
| 62 | Direct function: left button | Short key press | 1 Byte | CRT | |
| 62 | Direct function: left button | Toggle Heating/Cooling | 1 Bit | CRT | |
| 62 | Direct function: left button | Short key press | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 63 | Direct function | Dimming | 4 Bit | 3.7 dimming control | CRT |
| 63 | Direct function | Stop/Slats Open/Close | 1 Bit | 1.9 open/close | CRT |
| 63 | Direct function: left button | Value for toggle | 1 Bit | 1.1 switch | CWTU |
| 63 | Direct function: left button | Value for toggle short | 1 Bit | 1.1 switch | CWTU |
| 63 | Direct function: left button | Value for toggle | 1 Bit | CWTU | |
| 64 | Direct function: left button | Scene | 1 Byte | CRT | |
| 64 | Direct function: left button | Long key press | 1 Bit | 1.1 switch | CRT |
| 64 | Direct function: left button | Long key press | 1 Byte | CRT | |
| 64 | Direct function | Status dimming value | 1 Byte | 5.1 percentage (0..100%) | CW |
| 64 | Direct function | Status absolute position | 1 Byte | 5.1 percentage (0..100%) | CW |
| 64 | Direct function: left button | Long key press | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 65 | Direct function: right button | Switch | 1 Bit | 1.1 switch | CRT |
| 65 | Direct function: right button | send value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 65 | Direct function: right button | Short key press | 1 Bit | 1.1 switch | CRT |
| 65 | Direct function: right button | Short key press | 1 Byte | CRT | |
| 65 | Direct function: right button | Toggle Heating/Cooling | 1 Bit | CRT | |
| 65 | Direct function: right button | Short key press | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 66 | Direct function: right button | Value for toggle | 1 Bit | 1.1 switch | CWTU |
| 66 | Direct function: right button | Value for toggle | 1 Bit | CWTU | |
| 67 | Direct function: right button | Scene | 1 Byte | CRT | |
| 67 | Direct function: right button | Long key press | 1 Bit | 1.1 switch | CRT |
| 67 | Direct function: right button | Long key press | 1 Byte | CRT | |
| 67 | Direct function: right button | Long key press | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 68 | Function 1 | Switch On/Off | 1 Bit | 1.1 switch | CRT |
| 68 | Function 1 | Day/Night Switch | 1 Bit | 1.1 switch | CRT |
| 68 | Function 1 | Send value (0…255) | 1 Byte | CRT | |
| 68 | Function 1 | Send value (0…100%) | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 68 | Function 1 | Send HVAC mode | 1 Byte | CRT | |
| 68 | Function 1 | Send setpoint comfort | 2 Bytes | 9.1 temperature (°C) | CRT |
| 68 | Function 1 | Dimming on/off | 1 Bit | 1.1 switch | CRT |
| 68 | Function 1 | Shutter Down/Up | 1 Bit | 1.8 up/down | CRT |
| 68 | Function 1 | Send setpoint value offset | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 68 | Function 1 | Send setpoint value offset | 1 Bit | 1.8 up/down | CRT |
| 69 | Function 1 | Dimming | 4 Bit | 3.7 dimming control | CRT |
| 69 | Function 1 | Stop/Slats Open/Close | 1 Bit | 1.9 open/close | CRT |
| 70 | Function 1 | Status dimming value | 1 Byte | 5.1 percentage (0..100%) | CW |
| 70 | Function 1 | Status absolute position | 1 Byte | 5.1 percentage (0..100%) | CW |
| 70 | Function 1 | Scene | 1 Byte | CRT | |
| 70 | Function 1 | Status current setpoint | 2 Bytes | 9.1 temperature (°C) | CW |
| 70 | Function 1 | Status On/Off | 1 Bit | 1.1 switch | CW |
| 70 | Function 1 | Status Day/Night | 1 Bit | 1.1 switch | CW |
| 71 | Function 2 | Switch On/Off | 1 Bit | 1.1 switch | CRT |
| 71 | Function 2 | Day/Night Switch | 1 Bit | 1.1 switch | CRT |
| 71 | Function 2 | Send value (0…255) | 1 Byte | CRT | |
| 71 | Function 2 | Send value (0…100%) | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 71 | Function 2 | Send HVAC mode | 1 Byte | CRT | |
| 71 | Function 2 | Send setpoint comfort | 2 Bytes | 9.1 temperature (°C) | CRT |
| 71 | Function 2 | Dimming on/off | 1 Bit | 1.1 switch | CRT |
| 71 | Function 2 | Shutter Down/Up | 1 Bit | 1.8 up/down | CRT |
| 71 | Function 2 | Send setpoint value offset | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 71 | Function 2 | Send setpoint value offset | 1 Bit | 1.8 up/down | CRT |
| 72 | Function 2 | Dimming | 4 Bit | 3.7 dimming control | CRT |
| 72 | Function 2 | Stop/Slats Open/Close | 1 Bit | 1.9 open/close | CRT |
| 73 | Function 2 | Status dimming value | 1 Byte | 5.1 percentage (0..100%) | CW |
| 73 | Function 2 | Status absolute position | 1 Byte | 5.1 percentage (0..100%) | CW |
| 73 | Function 2 | Scene | 1 Byte | CRT | |
| 73 | Function 2 | Status current setpoint | 2 Bytes | 9.1 temperature (°C) | CW |
| 73 | Function 2 | Status On/Off | 1 Bit | 1.1 switch | CW |
| 73 | Function 2 | Status Day/Night | 1 Bit | 1.1 switch | CW |
| 74 | Function 3 | Switch On/Off | 1 Bit | 1.1 switch | CRT |
| 74 | Function 3 | Day/Night Switch | 1 Bit | 1.1 switch | CRT |
| 74 | Function 3 | Send value (0…255) | 1 Byte | CRT | |
| 74 | Function 3 | Send value (0…100%) | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 74 | Function 3 | Send HVAC mode | 1 Byte | CRT | |
| 74 | Function 3 | Send setpoint comfort | 2 Bytes | 9.1 temperature (°C) | CRT |
| 74 | Function 3 | Dimming on/off | 1 Bit | 1.1 switch | CRT |
| 74 | Function 3 | Shutter Down/Up | 1 Bit | 1.8 up/down | CRT |
| 74 | Function 3 | Send setpoint value offset | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 74 | Function 3 | Send setpoint value offset | 1 Bit | 1.8 up/down | CRT |
| 75 | Function 3 | Dimming | 4 Bit | 3.7 dimming control | CRT |
| 75 | Function 3 | Stop/Slats Open/Close | 1 Bit | 1.9 open/close | CRT |
| 76 | Function 3 | Status dimming value | 1 Byte | 5.1 percentage (0..100%) | CW |
| 76 | Function 3 | Status absolute position | 1 Byte | 5.1 percentage (0..100%) | CW |
| 76 | Function 3 | Scene | 1 Byte | CRT | |
| 76 | Function 3 | Status current setpoint | 2 Bytes | 9.1 temperature (°C) | CW |
| 76 | Function 3 | Status On/Off | 1 Bit | 1.1 switch | CW |
| 76 | Function 3 | Status Day/Night | 1 Bit | 1.1 switch | CW |
| 77 | Function 4 | Switch On/Off | 1 Bit | 1.1 switch | CRT |
| 77 | Function 4 | Day/Night Switch | 1 Bit | 1.1 switch | CRT |
| 77 | Function 4 | Send value (0…255) | 1 Byte | CRT | |
| 77 | Function 4 | Send value (0…100%) | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 77 | Function 4 | Send HVAC mode | 1 Byte | CRT | |
| 77 | Function 4 | Send setpoint comfort | 2 Bytes | 9.1 temperature (°C) | CRT |
| 77 | Function 4 | Dimming on/off | 1 Bit | 1.1 switch | CRT |
| 77 | Function 4 | Shutter Down/Up | 1 Bit | 1.8 up/down | CRT |
| 77 | Function 4 | Send setpoint value offset | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 77 | Function 4 | Send setpoint value offset | 1 Bit | 1.8 up/down | CRT |
| 78 | Function 4 | Dimming | 4 Bit | 3.7 dimming control | CRT |
| 78 | Function 4 | Stop/Slats Open/Close | 1 Bit | 1.9 open/close | CRT |
| 79 | Function 4 | Status dimming value | 1 Byte | 5.1 percentage (0..100%) | CW |
| 79 | Function 4 | Status absolute position | 1 Byte | 5.1 percentage (0..100%) | CW |
| 79 | Function 4 | Scene | 1 Byte | CRT | |
| 79 | Function 4 | Status current setpoint | 2 Bytes | 9.1 temperature (°C) | CW |
| 79 | Function 4 | Status On/Off | 1 Bit | 1.1 switch | CW |
| 79 | Function 4 | Status Day/Night | 1 Bit | 1.1 switch | CW |
| 80 | Function 5 | Switch On/Off | 1 Bit | 1.1 switch | CRT |
| 80 | Function 5 | Day/Night Switch | 1 Bit | 1.1 switch | CRT |
| 80 | Function 5 | Send value (0…255) | 1 Byte | CRT | |
| 80 | Function 5 | Send value (0…100%) | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 80 | Function 5 | Send HVAC mode | 1 Byte | CRT | |
| 80 | Function 5 | Send setpoint comfort | 2 Bytes | 9.1 temperature (°C) | CRT |
| 80 | Function 5 | Dimming on/off | 1 Bit | 1.1 switch | CRT |
| 80 | Function 5 | Shutter Down/Up | 1 Bit | 1.8 up/down | CRT |
| 80 | Function 5 | Send setpoint value offset | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 80 | Function 5 | Send setpoint value offset | 1 Bit | 1.8 up/down | CRT |
| 81 | Function 5 | Dimming | 4 Bit | 3.7 dimming control | CRT |
| 81 | Function 5 | Stop/Slats Open/Close | 1 Bit | 1.9 open/close | CRT |
| 82 | Function 5 | Status dimming value | 1 Byte | 5.1 percentage (0..100%) | CW |
| 82 | Function 5 | Status absolute position | 1 Byte | 5.1 percentage (0..100%) | CW |
| 82 | Function 5 | Scene | 1 Byte | CRT | |
| 82 | Function 5 | Status current setpoint | 2 Bytes | 9.1 temperature (°C) | CW |
| 82 | Function 5 | Status On/Off | 1 Bit | 1.1 switch | CW |
| 82 | Function 5 | Status Day/Night | 1 Bit | 1.1 switch | CW |
| 83 | Function 6 | Switch On/Off | 1 Bit | 1.1 switch | CRT |
| 83 | Function 6 | Day/Night Switch | 1 Bit | 1.1 switch | CRT |
| 83 | Function 6 | Send value (0…255) | 1 Byte | CRT | |
| 83 | Function 6 | Send value (0…100%) | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 83 | Function 6 | Send HVAC mode | 1 Byte | CRT | |
| 83 | Function 6 | Send setpoint comfort | 2 Bytes | 9.1 temperature (°C) | CRT |
| 83 | Function 6 | Dimming on/off | 1 Bit | 1.1 switch | CRT |
| 83 | Function 6 | Shutter Down/Up | 1 Bit | 1.8 up/down | CRT |
| 83 | Function 6 | Send setpoint value offset | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 83 | Function 6 | Send setpoint value offset | 1 Bit | 1.8 up/down | CRT |
| 84 | Function 6 | Dimming | 4 Bit | 3.7 dimming control | CRT |
| 84 | Function 6 | Stop/Slats Open/Close | 1 Bit | 1.9 open/close | CRT |
| 85 | Function 6 | Status dimming value | 1 Byte | 5.1 percentage (0..100%) | CW |
| 85 | Function 6 | Status absolute position | 1 Byte | 5.1 percentage (0..100%) | CW |
| 85 | Function 6 | Scene | 1 Byte | CRT | |
| 85 | Function 6 | Status current setpoint | 2 Bytes | 9.1 temperature (°C) | CW |
| 85 | Function 6 | Status On/Off | 1 Bit | 1.1 switch | CW |
| 85 | Function 6 | Status Day/Night | 1 Bit | 1.1 switch | CW |
| 86 | Function 7 | Switch On/Off | 1 Bit | 1.1 switch | CRT |
| 86 | Function 7 | Day/Night Switch | 1 Bit | 1.1 switch | CRT |
| 86 | Function 7 | Send value (0…255) | 1 Byte | CRT | |
| 86 | Function 7 | Send value (0…100%) | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 86 | Function 7 | Send HVAC mode | 1 Byte | CRT | |
| 86 | Function 7 | Send setpoint comfort | 2 Bytes | 9.1 temperature (°C) | CRT |
| 86 | Function 7 | Dimming on/off | 1 Bit | 1.1 switch | CRT |
| 86 | Function 7 | Shutter Down/Up | 1 Bit | 1.8 up/down | CRT |
| 86 | Function 7 | Send setpoint value offset | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 86 | Function 7 | Send setpoint value offset | 1 Bit | 1.8 up/down | CRT |
| 87 | Function 7 | Dimming | 4 Bit | 3.7 dimming control | CRT |
| 87 | Function 7 | Stop/Slats Open/Close | 1 Bit | 1.9 open/close | CRT |
| 88 | Function 7 | Status dimming value | 1 Byte | 5.1 percentage (0..100%) | CW |
| 88 | Function 7 | Status absolute position | 1 Byte | 5.1 percentage (0..100%) | CW |
| 88 | Function 7 | Scene | 1 Byte | CRT | |
| 88 | Function 7 | Status current setpoint | 2 Bytes | 9.1 temperature (°C) | CW |
| 88 | Function 7 | Status On/Off | 1 Bit | 1.1 switch | CW |
| 88 | Function 7 | Status Day/Night | 1 Bit | 1.1 switch | CW |
| 89 | Function 8 | Switch On/Off | 1 Bit | 1.1 switch | CRT |
| 89 | Function 8 | Day/Night Switch | 1 Bit | 1.1 switch | CRT |
| 89 | Function 8 | Send value (0…255) | 1 Byte | CRT | |
| 89 | Function 8 | Send value (0…100%) | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 89 | Function 8 | Send HVAC mode | 1 Byte | CRT | |
| 89 | Function 8 | Send setpoint comfort | 2 Bytes | 9.1 temperature (°C) | CRT |
| 89 | Function 8 | Dimming on/off | 1 Bit | 1.1 switch | CRT |
| 89 | Function 8 | Shutter Down/Up | 1 Bit | 1.8 up/down | CRT |
| 89 | Function 8 | Send setpoint value offset | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 89 | Function 8 | Send setpoint value offset | 1 Bit | 1.8 up/down | CRT |
| 90 | Function 8 | Dimming | 4 Bit | 3.7 dimming control | CRT |
| 90 | Function 8 | Stop/Slats Open/Close | 1 Bit | 1.9 open/close | CRT |
| 91 | Function 8 | Status dimming value | 1 Byte | 5.1 percentage (0..100%) | CW |
| 91 | Function 8 | Status absolute position | 1 Byte | 5.1 percentage (0..100%) | CW |
| 91 | Function 8 | Scene | 1 Byte | CRT | |
| 91 | Function 8 | Status current setpoint | 2 Bytes | 9.1 temperature (°C) | CW |
| 91 | Function 8 | Status On/Off | 1 Bit | 1.1 switch | CW |
| 91 | Function 8 | Status Day/Night | 1 Bit | 1.1 switch | CW |
| 92 | Function 9 | Switch On/Off | 1 Bit | 1.1 switch | CRT |
| 92 | Function 9 | Day/Night Switch | 1 Bit | 1.1 switch | CRT |
| 92 | Function 9 | Send value (0…255) | 1 Byte | CRT | |
| 92 | Function 9 | Send value (0…100%) | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 92 | Function 9 | Send HVAC mode | 1 Byte | CRT | |
| 92 | Function 9 | Send setpoint comfort | 2 Bytes | 9.1 temperature (°C) | CRT |
| 92 | Function 9 | Dimming on/off | 1 Bit | 1.1 switch | CRT |
| 92 | Function 9 | Shutter Down/Up | 1 Bit | 1.8 up/down | CRT |
| 92 | Function 9 | Send setpoint value offset | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 92 | Function 9 | Send setpoint value offset | 1 Bit | 1.8 up/down | CRT |
| 93 | Function 9 | Dimming | 4 Bit | 3.7 dimming control | CRT |
| 93 | Function 9 | Stop/Slats Open/Close | 1 Bit | 1.9 open/close | CRT |
| 94 | Function 9 | Status dimming value | 1 Byte | 5.1 percentage (0..100%) | CW |
| 94 | Function 9 | Status absolute position | 1 Byte | 5.1 percentage (0..100%) | CW |
| 94 | Function 9 | Scene | 1 Byte | CRT | |
| 94 | Function 9 | Status current setpoint | 2 Bytes | 9.1 temperature (°C) | CW |
| 94 | Function 9 | Status On/Off | 1 Bit | 1.1 switch | CW |
| 94 | Function 9 | Status Day/Night | 1 Bit | 1.1 switch | CW |
| 95 | Function 10 | Switch On/Off | 1 Bit | 1.1 switch | CRT |
| 95 | Function 10 | Day/Night Switch | 1 Bit | 1.1 switch | CRT |
| 95 | Function 10 | Send value (0…255) | 1 Byte | CRT | |
| 95 | Function 10 | Send value (0…100%) | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 95 | Function 10 | Send HVAC mode | 1 Byte | CRT | |
| 95 | Function 10 | Send setpoint comfort | 2 Bytes | 9.1 temperature (°C) | CRT |
| 95 | Function 10 | Dimming on/off | 1 Bit | 1.1 switch | CRT |
| 95 | Function 10 | Shutter Down/Up | 1 Bit | 1.8 up/down | CRT |
| 95 | Function 10 | Send setpoint value offset | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 95 | Function 10 | Send setpoint value offset | 1 Bit | 1.8 up/down | CRT |
| 96 | Function 10 | Dimming | 4 Bit | 3.7 dimming control | CRT |
| 96 | Function 10 | Stop/Slats Open/Close | 1 Bit | 1.9 open/close | CRT |
| 97 | Function 10 | Status dimming value | 1 Byte | 5.1 percentage (0..100%) | CW |
| 97 | Function 10 | Status absolute position | 1 Byte | 5.1 percentage (0..100%) | CW |
| 97 | Function 10 | Scene | 1 Byte | CRT | |
| 97 | Function 10 | Status current setpoint | 2 Bytes | 9.1 temperature (°C) | CW |
| 97 | Function 10 | Status On/Off | 1 Bit | 1.1 switch | CW |
| 97 | Function 10 | Status Day/Night | 1 Bit | 1.1 switch | CW |
| 98 | Function 11 | Switch On/Off | 1 Bit | 1.1 switch | CRT |
| 98 | Function 11 | Day/Night Switch | 1 Bit | 1.1 switch | CRT |
| 98 | Function 11 | Send value (0…255) | 1 Byte | CRT | |
| 98 | Function 11 | Send value (0…100%) | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 98 | Function 11 | Send HVAC mode | 1 Byte | CRT | |
| 98 | Function 11 | Send setpoint comfort | 2 Bytes | 9.1 temperature (°C) | CRT |
| 98 | Function 11 | Dimming on/off | 1 Bit | 1.1 switch | CRT |
| 98 | Function 11 | Shutter Down/Up | 1 Bit | 1.8 up/down | CRT |
| 98 | Function 11 | Send setpoint value offset | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 98 | Function 11 | Send setpoint value offset | 1 Bit | 1.8 up/down | CRT |
| 99 | Function 11 | Dimming | 4 Bit | 3.7 dimming control | CRT |
| 99 | Function 11 | Stop/Slats Open/Close | 1 Bit | 1.9 open/close | CRT |
| 100 | Function 11 | Status dimming value | 1 Byte | 5.1 percentage (0..100%) | CW |
| 100 | Function 11 | Status absolute position | 1 Byte | 5.1 percentage (0..100%) | CW |
| 100 | Function 11 | Scene | 1 Byte | CRT | |
| 100 | Function 11 | Status current setpoint | 2 Bytes | 9.1 temperature (°C) | CW |
| 100 | Function 11 | Status On/Off | 1 Bit | 1.1 switch | CW |
| 100 | Function 11 | Status Day/Night | 1 Bit | 1.1 switch | CW |
| 101 | Function 12 | Switch On/Off | 1 Bit | 1.1 switch | CRT |
| 101 | Function 12 | Day/Night Switch | 1 Bit | 1.1 switch | CRT |
| 101 | Function 12 | Send value (0…255) | 1 Byte | CRT | |
| 101 | Function 12 | Send value (0…100%) | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 101 | Function 12 | Send HVAC mode | 1 Byte | CRT | |
| 101 | Function 12 | Send setpoint comfort | 2 Bytes | 9.1 temperature (°C) | CRT |
| 101 | Function 12 | Dimming on/off | 1 Bit | 1.1 switch | CRT |
| 101 | Function 12 | Shutter Down/Up | 1 Bit | 1.8 up/down | CRT |
| 101 | Function 12 | Send setpoint value offset | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 101 | Function 12 | Send setpoint value offset | 1 Bit | 1.8 up/down | CRT |
| 102 | Function 12 | Dimming | 4 Bit | 3.7 dimming control | CRT |
| 102 | Function 12 | Stop/Slats Open/Close | 1 Bit | 1.9 open/close | CRT |
| 103 | Function 12 | Status dimming value | 1 Byte | 5.1 percentage (0..100%) | CW |
| 103 | Function 12 | Status absolute position | 1 Byte | 5.1 percentage (0..100%) | CW |
| 103 | Function 12 | Scene | 1 Byte | CRT | |
| 103 | Function 12 | Status current setpoint | 2 Bytes | 9.1 temperature (°C) | CW |
| 103 | Function 12 | Status On/Off | 1 Bit | 1.1 switch | CW |
| 103 | Function 12 | Status Day/Night | 1 Bit | 1.1 switch | CW |
| 104 | Function 13 | Switch On/Off | 1 Bit | 1.1 switch | CRT |
| 104 | Function 13 | Day/Night Switch | 1 Bit | 1.1 switch | CRT |
| 104 | Function 13 | Send value (0…255) | 1 Byte | CRT | |
| 104 | Function 13 | Send value (0…100%) | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 104 | Function 13 | Send HVAC mode | 1 Byte | CRT | |
| 104 | Function 13 | Send setpoint comfort | 2 Bytes | 9.1 temperature (°C) | CRT |
| 104 | Function 13 | Dimming on/off | 1 Bit | 1.1 switch | CRT |
| 104 | Function 13 | Shutter Down/Up | 1 Bit | 1.8 up/down | CRT |
| 104 | Function 13 | Send setpoint value offset | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 104 | Function 13 | Send setpoint value offset | 1 Bit | 1.8 up/down | CRT |
| 105 | Function 13 | Dimming | 4 Bit | 3.7 dimming control | CRT |
| 105 | Function 13 | Stop/Slats Open/Close | 1 Bit | 1.9 open/close | CRT |
| 106 | Function 13 | Status dimming value | 1 Byte | 5.1 percentage (0..100%) | CW |
| 106 | Function 13 | Status absolute position | 1 Byte | 5.1 percentage (0..100%) | CW |
| 106 | Function 13 | Scene | 1 Byte | CRT | |
| 106 | Function 13 | Status current setpoint | 2 Bytes | 9.1 temperature (°C) | CW |
| 106 | Function 13 | Status On/Off | 1 Bit | 1.1 switch | CW |
| 106 | Function 13 | Status Day/Night | 1 Bit | 1.1 switch | CW |
| 107 | Function 14 | Switch On/Off | 1 Bit | 1.1 switch | CRT |
| 107 | Function 14 | Day/Night Switch | 1 Bit | 1.1 switch | CRT |
| 107 | Function 14 | Send value (0…255) | 1 Byte | CRT | |
| 107 | Function 14 | Send value (0…100%) | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 107 | Function 14 | Send HVAC mode | 1 Byte | CRT | |
| 107 | Function 14 | Send setpoint comfort | 2 Bytes | 9.1 temperature (°C) | CRT |
| 107 | Function 14 | Dimming on/off | 1 Bit | 1.1 switch | CRT |
| 107 | Function 14 | Shutter Down/Up | 1 Bit | 1.8 up/down | CRT |
| 107 | Function 14 | Send setpoint value offset | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 107 | Function 14 | Send setpoint value offset | 1 Bit | 1.8 up/down | CRT |
| 108 | Function 14 | Dimming | 4 Bit | 3.7 dimming control | CRT |
| 108 | Function 14 | Stop/Slats Open/Close | 1 Bit | 1.9 open/close | CRT |
| 109 | Function 14 | Status dimming value | 1 Byte | 5.1 percentage (0..100%) | CW |
| 109 | Function 14 | Status absolute position | 1 Byte | 5.1 percentage (0..100%) | CW |
| 109 | Function 14 | Scene | 1 Byte | CRT | |
| 109 | Function 14 | Status current setpoint | 2 Bytes | 9.1 temperature (°C) | CW |
| 109 | Function 14 | Status On/Off | 1 Bit | 1.1 switch | CW |
| 109 | Function 14 | Status Day/Night | 1 Bit | 1.1 switch | CW |
| 110 | Function 15 | Switch On/Off | 1 Bit | 1.1 switch | CRT |
| 110 | Function 15 | Day/Night Switch | 1 Bit | 1.1 switch | CRT |
| 110 | Function 15 | Send value (0…255) | 1 Byte | CRT | |
| 110 | Function 15 | Send value (0…100%) | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 110 | Function 15 | Send HVAC mode | 1 Byte | CRT | |
| 110 | Function 15 | Send setpoint comfort | 2 Bytes | 9.1 temperature (°C) | CRT |
| 110 | Function 15 | Dimming on/off | 1 Bit | 1.1 switch | CRT |
| 110 | Function 15 | Shutter Down/Up | 1 Bit | 1.8 up/down | CRT |
| 110 | Function 15 | Send setpoint value offset | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 110 | Function 15 | Send setpoint value offset | 1 Bit | 1.8 up/down | CRT |
| 111 | Function 15 | Dimming | 4 Bit | 3.7 dimming control | CRT |
| 111 | Function 15 | Stop/Slats Open/Close | 1 Bit | 1.9 open/close | CRT |
| 112 | Function 15 | Status dimming value | 1 Byte | 5.1 percentage (0..100%) | CW |
| 112 | Function 15 | Status absolute position | 1 Byte | 5.1 percentage (0..100%) | CW |
| 112 | Function 15 | Scene | 1 Byte | CRT | |
| 112 | Function 15 | Status current setpoint | 2 Bytes | 9.1 temperature (°C) | CW |
| 112 | Function 15 | Status On/Off | 1 Bit | 1.1 switch | CW |
| 112 | Function 15 | Status Day/Night | 1 Bit | 1.1 switch | CW |
| 113 | Function 16 | Switch On/Off | 1 Bit | 1.1 switch | CRT |
| 113 | Function 16 | Day/Night Switch | 1 Bit | 1.1 switch | CRT |
| 113 | Function 16 | Send value (0…255) | 1 Byte | CRT | |
| 113 | Function 16 | Send value (0…100%) | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 113 | Function 16 | Send HVAC mode | 1 Byte | CRT | |
| 113 | Function 16 | Send setpoint comfort | 2 Bytes | 9.1 temperature (°C) | CRT |
| 113 | Function 16 | Dimming on/off | 1 Bit | 1.1 switch | CRT |
| 113 | Function 16 | Shutter Down/Up | 1 Bit | 1.8 up/down | CRT |
| 113 | Function 16 | Send setpoint value offset | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 113 | Function 16 | Send setpoint value offset | 1 Bit | 1.8 up/down | CRT |
| 114 | Function 16 | Dimming | 4 Bit | 3.7 dimming control | CRT |
| 114 | Function 16 | Stop/Slats Open/Close | 1 Bit | 1.9 open/close | CRT |
| 115 | Function 16 | Status dimming value | 1 Byte | 5.1 percentage (0..100%) | CW |
| 115 | Function 16 | Status absolute position | 1 Byte | 5.1 percentage (0..100%) | CW |
| 115 | Function 16 | Scene | 1 Byte | CRT | |
| 115 | Function 16 | Status current setpoint | 2 Bytes | 9.1 temperature (°C) | CW |
| 115 | Function 16 | Status On/Off | 1 Bit | 1.1 switch | CW |
| 115 | Function 16 | Status Day/Night | 1 Bit | 1.1 switch | CW |
| 116 | Function 17 | Switch On/Off | 1 Bit | 1.1 switch | CRT |
| 116 | Function 17 | Day/Night Switch | 1 Bit | 1.1 switch | CRT |
| 116 | Function 17 | Send value (0…255) | 1 Byte | CRT | |
| 116 | Function 17 | Send value (0…100%) | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 116 | Function 17 | Send HVAC mode | 1 Byte | CRT | |
| 116 | Function 17 | Send setpoint comfort | 2 Bytes | 9.1 temperature (°C) | CRT |
| 116 | Function 17 | Dimming on/off | 1 Bit | 1.1 switch | CRT |
| 116 | Function 17 | Shutter Down/Up | 1 Bit | 1.8 up/down | CRT |
| 116 | Function 17 | Send setpoint value offset | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 116 | Function 17 | Send setpoint value offset | 1 Bit | 1.8 up/down | CRT |
| 117 | Function 17 | Dimming | 4 Bit | 3.7 dimming control | CRT |
| 117 | Function 17 | Stop/Slats Open/Close | 1 Bit | 1.9 open/close | CRT |
| 118 | Function 17 | Status dimming value | 1 Byte | 5.1 percentage (0..100%) | CW |
| 118 | Function 17 | Status absolute position | 1 Byte | 5.1 percentage (0..100%) | CW |
| 118 | Function 17 | Scene | 1 Byte | CRT | |
| 118 | Function 17 | Status current setpoint | 2 Bytes | 9.1 temperature (°C) | CW |
| 118 | Function 17 | Status On/Off | 1 Bit | 1.1 switch | CW |
| 118 | Function 17 | Status Day/Night | 1 Bit | 1.1 switch | CW |
| 119 | Function 18 | Switch On/Off | 1 Bit | 1.1 switch | CRT |
| 119 | Function 18 | Day/Night Switch | 1 Bit | 1.1 switch | CRT |
| 119 | Function 18 | Send value (0…255) | 1 Byte | CRT | |
| 119 | Function 18 | Send value (0…100%) | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 119 | Function 18 | Send HVAC mode | 1 Byte | CRT | |
| 119 | Function 18 | Send setpoint comfort | 2 Bytes | 9.1 temperature (°C) | CRT |
| 119 | Function 18 | Dimming on/off | 1 Bit | 1.1 switch | CRT |
| 119 | Function 18 | Shutter Down/Up | 1 Bit | 1.8 up/down | CRT |
| 119 | Function 18 | Send setpoint value offset | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 119 | Function 18 | Send setpoint value offset | 1 Bit | 1.8 up/down | CRT |
| 120 | Function 18 | Dimming | 4 Bit | 3.7 dimming control | CRT |
| 120 | Function 18 | Stop/Slats Open/Close | 1 Bit | 1.9 open/close | CRT |
| 121 | Function 18 | Status dimming value | 1 Byte | 5.1 percentage (0..100%) | CW |
| 121 | Function 18 | Status absolute position | 1 Byte | 5.1 percentage (0..100%) | CW |
| 121 | Function 18 | Scene | 1 Byte | CRT | |
| 121 | Function 18 | Status current setpoint | 2 Bytes | 9.1 temperature (°C) | CW |
| 121 | Function 18 | Status On/Off | 1 Bit | 1.1 switch | CW |
| 121 | Function 18 | Status Day/Night | 1 Bit | 1.1 switch | CW |
| 122 | Function 19 | Switch On/Off | 1 Bit | 1.1 switch | CRT |
| 122 | Function 19 | Day/Night Switch | 1 Bit | 1.1 switch | CRT |
| 122 | Function 19 | Send value (0…255) | 1 Byte | CRT | |
| 122 | Function 19 | Send value (0…100%) | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 122 | Function 19 | Send HVAC mode | 1 Byte | CRT | |
| 122 | Function 19 | Send setpoint comfort | 2 Bytes | 9.1 temperature (°C) | CRT |
| 122 | Function 19 | Dimming on/off | 1 Bit | 1.1 switch | CRT |
| 122 | Function 19 | Shutter Down/Up | 1 Bit | 1.8 up/down | CRT |
| 122 | Function 19 | Send setpoint value offset | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 122 | Function 19 | Send setpoint value offset | 1 Bit | 1.8 up/down | CRT |
| 123 | Function 19 | Dimming | 4 Bit | 3.7 dimming control | CRT |
| 123 | Function 19 | Stop/Slats Open/Close | 1 Bit | 1.9 open/close | CRT |
| 124 | Function 19 | Status dimming value | 1 Byte | 5.1 percentage (0..100%) | CW |
| 124 | Function 19 | Status absolute position | 1 Byte | 5.1 percentage (0..100%) | CW |
| 124 | Function 19 | Scene | 1 Byte | CRT | |
| 124 | Function 19 | Status current setpoint | 2 Bytes | 9.1 temperature (°C) | CW |
| 124 | Function 19 | Status On/Off | 1 Bit | 1.1 switch | CW |
| 124 | Function 19 | Status Day/Night | 1 Bit | 1.1 switch | CW |
| 125 | Function 20 | Switch On/Off | 1 Bit | 1.1 switch | CRT |
| 125 | Function 20 | Day/Night Switch | 1 Bit | 1.1 switch | CRT |
| 125 | Function 20 | Send value (0…255) | 1 Byte | CRT | |
| 125 | Function 20 | Send value (0…100%) | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 125 | Function 20 | Send HVAC mode | 1 Byte | CRT | |
| 125 | Function 20 | Send setpoint comfort | 2 Bytes | 9.1 temperature (°C) | CRT |
| 125 | Function 20 | Dimming on/off | 1 Bit | 1.1 switch | CRT |
| 125 | Function 20 | Shutter Down/Up | 1 Bit | 1.8 up/down | CRT |
| 125 | Function 20 | Send setpoint value offset | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 125 | Function 20 | Send setpoint value offset | 1 Bit | 1.8 up/down | CRT |
| 126 | Function 20 | Dimming | 4 Bit | 3.7 dimming control | CRT |
| 126 | Function 20 | Stop/Slats Open/Close | 1 Bit | 1.9 open/close | CRT |
| 127 | Function 20 | Status dimming value | 1 Byte | 5.1 percentage (0..100%) | CW |
| 127 | Function 20 | Status absolute position | 1 Byte | 5.1 percentage (0..100%) | CW |
| 127 | Function 20 | Scene | 1 Byte | CRT | |
| 127 | Function 20 | Status current setpoint | 2 Bytes | 9.1 temperature (°C) | CW |
| 127 | Function 20 | Status On/Off | 1 Bit | 1.1 switch | CW |
| 127 | Function 20 | Status Day/Night | 1 Bit | 1.1 switch | CW |
| 128 | Lock 1 | Lock Time Switch | 1 Bit | 1.3 enable | CW |
| 128 | Lock 1 | Holiday function | 1 Bit | 1.1 switch | CRT |
| 129 | Lock 2 | Lock Time Switch | 1 Bit | 1.3 enable | CW |
| 129 | Lock 2 | Holiday function | 1 Bit | 1.1 switch | CRT |
| 130 | Logic A | Input logic 1 | 1 Bit | 1.2 boolean | CWT |
| 131 | Logic A | Input logic 2 | 1 Bit | 1.2 boolean | CWT |
| 132 | Logic A | Input logic 3 | 1 Bit | 1.2 boolean | CWT |
| 133 | Logic A | Input logic 4 | 1 Bit | 1.2 boolean | CWT |
| 134 | Logic A | Output Switch | 1 Bit | 1.2 boolean | CRT |
| 134 | Logic A | Output Scene | 1 Byte | CRT | |
| 134 | Logic A | Output value | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 135 | Logic B | Input logic 1 | 1 Bit | 1.2 boolean | CWT |
| 136 | Logic B | Input logic 2 | 1 Bit | 1.2 boolean | CWT |
| 137 | Logic B | Input logic 3 | 1 Bit | 1.2 boolean | CWT |
| 138 | Logic B | Input logic 4 | 1 Bit | 1.2 boolean | CWT |
| 139 | Logic B | Output Switch | 1 Bit | 1.2 boolean | CRT |
| 139 | Logic B | Output Scene | 1 Byte | CRT | |
| 139 | Logic B | Output value | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 140 | Logic C | Input logic 1 | 1 Bit | 1.2 boolean | CWT |
| 141 | Logic C | Input logic 2 | 1 Bit | 1.2 boolean | CWT |
| 142 | Logic C | Input logic 3 | 1 Bit | 1.2 boolean | CWT |
| 143 | Logic C | Input logic 4 | 1 Bit | 1.2 boolean | CWT |
| 144 | Logic C | Output Switch | 1 Bit | 1.2 boolean | CRT |
| 144 | Logic C | Output Scene | 1 Byte | CRT | |
| 144 | Logic C | Output value | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 145 | Logic D | Input logic 1 | 1 Bit | 1.2 boolean | CWT |
| 146 | Logic D | Input logic 2 | 1 Bit | 1.2 boolean | CWT |
| 147 | Logic D | Input logic 3 | 1 Bit | 1.2 boolean | CWT |
| 148 | Logic D | Input logic 4 | 1 Bit | 1.2 boolean | CWT |
| 149 | Logic D | Output Switch | 1 Bit | 1.2 boolean | CRT |
| 149 | Logic D | Output Scene | 1 Byte | CRT | |
| 149 | Logic D | Output value | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 150 | Logic E | Input logic 1 | 1 Bit | 1.2 boolean | CWT |
| 151 | Logic E | Input logic 2 | 1 Bit | 1.2 boolean | CWT |
| 152 | Logic E | Input logic 3 | 1 Bit | 1.2 boolean | CWT |
| 153 | Logic E | Input logic 4 | 1 Bit | 1.2 boolean | CWT |
| 154 | Logic E | Output Switch | 1 Bit | 1.2 boolean | CRT |
| 154 | Logic E | Output Scene | 1 Byte | CRT | |
| 154 | Logic E | Output value | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 155 | Logic F | Input logic 1 | 1 Bit | 1.2 boolean | CWT |
| 156 | Logic F | Input logic 2 | 1 Bit | 1.2 boolean | CWT |
| 157 | Logic F | Input logic 3 | 1 Bit | 1.2 boolean | CWT |
| 158 | Logic F | Input logic 4 | 1 Bit | 1.2 boolean | CWT |
| 159 | Logic F | Output Switch | 1 Bit | 1.2 boolean | CRT |
| 159 | Logic F | Output value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 159 | Logic F | Output Scene | 1 Byte | CRT | |
| 160 | Logic G | Input logic 1 | 1 Bit | 1.2 boolean | CWT |
| 161 | Logic G | Input logic 2 | 1 Bit | 1.2 boolean | CWT |
| 162 | Logic G | Input logic 3 | 1 Bit | 1.2 boolean | CWT |
| 163 | Logic G | Input logic 4 | 1 Bit | 1.2 boolean | CWT |
| 164 | Logic G | Output value | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 164 | Logic G | Output Switch | 1 Bit | 1.2 boolean | CRT |
| 164 | Logic G | Output Scene | 1 Byte | CRT | |
| 165 | Logic H | Input logic 1 | 1 Bit | 1.2 boolean | CWT |
| 166 | Logic H | Input logic 2 | 1 Bit | 1.2 boolean | CWT |
| 167 | Logic H | Input logic 3 | 1 Bit | 1.2 boolean | CWT |
| 168 | Logic H | Input logic 4 | 1 Bit | 1.2 boolean | CWT |
| 169 | Logic H | Output value | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 169 | Logic H | Output Scene | 1 Byte | CRT | |
| 169 | Logic H | Output value | 1 Bit | 1.2 boolean | CRT |
| 170 | Dummy | 1 Bit | |||
| 171 | Dummy | 1 Bit | |||
| 172 | Dummy | 1 Bit | |||
| 173 | Dummy | 1 Bit | |||
| 174 | Dummy | 1 Bit | |||
| 175 | Dummy | 1 Bit | |||
| 176 | Dummy | 1 Bit | |||
| 177 | Dummy | 1 Bit | |||
| 178 | Dummy | 1 Bit | |||
| 179 | Dummy | 1 Bit | |||
| 180 | Dummy | 1 Bit | |||
| 181 | Dummy | 1 Bit | |||
| 182 | Dummy | 1 Bit | |||
| 183 | Dummy | 1 Bit | |||
| 184 | Dummy | 1 Bit | |||
| 185 | Dummy | 1 Bit | |||
| 186 | Dummy | 1 Bit | |||
| 187 | Dummy | 1 Bit | |||
| 188 | Dummy | 1 Bit | |||
| 189 | Dummy | 1 Bit |
Parameters (322)
| Parameter | Type | Default |
|---|---|---|
| Startup delaytime | list | 0 s |
| Select hardware | list | SCN-RT1xP.xx without manual control |
| Day/Night polarity | list | Day = 1; Night = 0 |
| Query of day/night object after reset | list | no |
| System time mode | list | Master |
| Send system time cyclic | list | each 1 h |
| Query of time after reset | list | no |
| Time change | list | allow winter and summer time |
| Location determination by | list | place |
| Country | list | Belgium |
| Town | list | Antwerp |
| Latitude | list | north |
| Latitude in degrees [0° - 90°] | unsignedInt 0…90 | 50 |
| Latitude in minutes [0' - 59'] | unsignedInt 0…59 | 56 |
| Longitude | list | east |
| Longitude in degrees [0° - 180°] | unsignedInt 0…180 | 6 |
| Longitude in minutes [0' - 59'] | unsignedInt 0…59 | 57 |
| Time difference from Universal Time (UTC + ...) | list | (UTC +01:00) Amsterdam, Berlin, Bern, Rome, Vienna |
| Town | list | Aalborg |
| Town | list | Aachen |
| Town | list | Helsinki |
| Town | list | Ajaccio (Corsika) |
| Town | list | Athens |
| Town | list | Birmingham |
| Town | list | Cork |
| Town | list | Bari |
| Town | list | Luxembourg |
| Town | list | Amsterdam |
| Town | list | Bergen |
| Town | list | Feldkirch |
| Town | list | Breslau |
| Town | list | Braga |
| Town | list | Moskow |
| Town | list | Goteborg |
| Town | list | Basel |
| Town | list | Barcelona |
| Town | list | Prague |
| Invertierung des Displays aktivieren | list | no |
| Language | list | German |
| LCD-Alarm messages | list | inactive |
| Message 1 | text | Alarm 1 |
| Message is | list | saved |
| Message 2 | text | Alarm 2 |
| Message 3 | text | Alarm 3 |
| Message 4 | text | Alarm 4 |
| Text message 14 Byte is | list | saved |
| Standby display at day | list | only actual temperature |
| Standby display at night | list | only actual temperature |
| Change time between functional blocks | list | 2 s |
| Time until Display changes into Standby | list | 20 s |
| Functions of Time Switch via direct selection (left button) | list | active |
| Temperature controller via direct selection (left button) | list | active |
| Selection of mode at the dispaly | list | Comfort, Standby, Night, Frost |
| Step range for setpoint offset via display buttons | list | 0,2 K |
| Fan control via direct selection (left button) | list | active |
| Direct function via direct selection (left button) | list | active |
| Display buttons of direct function in Standby | list | yes |
| Representation after standby | list | Functions of Time Switch |
| Basic brightness | list | brightness 1 |
| Minimum brightness at day | list | bright |
| Minimum brightness at night | list | off |
| Helligkeit Sensor Min | unsignedInt 0…255 | 0 |
| Helligkeit Nacht Max | unsignedInt 0…255 | 255 |
| Helligkeit Tag Max | unsignedInt 0…255 | 255 |
| ------------------------------ | text | |
| Alarm | list | inactive |
| Frostalarm if value < | list | 7 °C |
| Heatalarm if value > | list | 35 °C |
| Messages | list | inactive |
| Message if value > | list | 26 °C |
| Message if value < | list | 13 °C |
| Send actual value after change of | list | disable |
| Send actual temperature cyclic | list | disable |
| Send min/max value | list | disable |
| Internal sensor correction value (value * 0.1K) | signedInt -50…50 | 0 |
| Internal/external sensor | list | 100 % intern |
| Query the outside temperature after reset | list | no |
| Controller type | list | Heating |
| Priority | list | Frost(Heat protection)/Comfort/Night/Standby |
| Basic comfort setpoint (°C) | list | 21,0 °C |
| Standby reduction (K) | list | 2,0 K |
| Night reduction (K) | list | 3,0 K |
| Setpoint frost protection (°C) | list | 7 °C |
| Max setpoint offset | list | 3,0 K |
| Set point value offset via 2Byte object | list | inactive |
| Set point value offset via 1Bit object | list | inactive |
| Step range | list | 0,5 K |
| Max setpoint offset vaild for | list | Comfort |
| Reset setpoint offset after change of mode | list | no |
| Send setpoint change | list | no |
| Flow temperature | list | inactive |
| Advanced function only for hardware starting from version 1.2 | text | <- TIP |
| Flow temperature limit | list | 40 °C |
| Operating mode after reset | list | Comfort with parameterized set point |
| Send status on object 31 "Mode selection" | list | no |
| Heating disable object | list | inactive |
| Heating request object enabled | list | no |
| Guiding | list | inactive |
| Guiding value minimum (°C) | signedInt -100…100 | 28 |
| Guiding value maximum (°C) | signedInt -100…100 | 38 |
| Setpoint variation at maximum guiding value (°C) | signedInt -100…100 | 10 |
| Standby increase (K) | list | 3,0 K |
| Night increase (K) | list | 2,0 K |
| Setpoint heat protection (°C) | list | 35 °C |
| Cooling disable object | list | inactive |
| Cooling request object enabled | list | no |
| Dead zone between heating and cooling (K) | list | 2,0 K |
| Setpoint | list | PI control continuous |
| Direction of controller | list | normal |
| Max value of control value | list | 100% |
| Heating system | list | adjustment via control parameter |
| Heating system | list | Underfloor heating (4K / 150min) |
| Proportional range (K) | list | 4 K |
| Reset time (min) | list | 120 min |
| Send control value cyclic | list | disable |
| PWM cycletime (min) | list | 10 min |
| Hysteresis (K) | list | 2,0 K |
| Use additional level | list | no |
| Setpoint | list | 2-step control (switching) |
| Distance (K) | list | 2,0 K |
| Cooling system | list | adjustment via control parameter |
| Cooling system | list | Cooling ceiling (4K / 150min) |
| Prop value K | list | 4 K |
| Reset time (min) | list | 60 min |
| System | list | 2 Pipe system |
| Heating/cooling switch over | list | automatically |
| Send control value for heating and cooling cyclic | list | disable |
| Send control output for heating and cooling cycles | list | disable |
| Ventilation control | list | inactive |
| Outputs cyclically send all | list | disable |
| Pause between individual levels [x100ms] | unsignedInt 0…255 | 0 |
| Type of thresholds | list | Control value |
| Total number of steps | list | 4 |
| Minimum level at day | list | Level 0 |
| Maximum level at day | list | Level 2 |
| Minimum level at night | list | Level 0 |
| Maximum level at night | list | Level 2 |
| Threshold level 1 | list | 10% |
| Threshold level 2 | list | 30% |
| Maximum level at day | list | Level 3 |
| Maximum level at night | list | Level 3 |
| Threshold level 3 | list | 50% |
| Maximum level at day | list | Level 4 |
| Maximum level at night | list | Level 4 |
| Threshold level 4 | list | 70% |
| Hysteresis | list | 5% |
| Behavior at lock | list | not use |
| Behavior when unlocking | list | no action |
| Level when unlocking | list | Level 0 |
| Level at lock | list | Level 0 |
| Threshold level 1 | list | 2,0 K |
| Threshold level 2 | list | 4,0 K |
| Threshold level 3 | list | 6,0 K |
| Threshold level 4 | list | 8,0 K |
| Hysteresis | list | 0,5 K |
| Behavior at init | list | Level 0 |
| Sticking protection (highest level trigger after 24 hours at level 0) | list | inactive |
| Priority | list | inactive |
| Switch priority with | list | Level 0 |
| Use status object 43 as | list | 1Bit Ventilation active |
| Output value for stage 1 at day | list | 10% |
| Output value for stage 1 at night | list | 10% |
| Output value for stage 2 at day | list | 30% |
| Output value for stage 2 at night | list | 30% |
| Output value for stage 3 at day | list | 50% |
| Output value for stage 3 at night | list | 50% |
| Output value for stage 4 at day | list | 70% |
| Output value for stage 4 at night | list | 70% |
| Entprellzeit [ms] | list | 60 ms |
| Zeit langer Tastendruck [s] | list | 0,6 s |
| Buttons function | list | inactive |
| Key function (Button A) | list | inactive |
| Key function (Button B) | list | inactive |
| Description of the funnction in the display | text | Funktion 1 |
| Key function | list | Dimming |
| Switch function | list | Button C = Off / Button D = On |
| Funktion | list | Switch |
| Value for released key | list | off |
| Value for key operation | list | on |
| Dimming function | list | Button C = darker / Button D = brighter |
| 1Byte value [0…255] | unsignedInt 0…255 | 3 |
| Shutter function | list | Button C = Down / Button D = Up |
| 1-B Shutter | list | inactive |
| Operating function | list | Long=Moving / Short=Stop/Slats Open/Close |
| Subfunction | list | toggle on key press |
| Value for key operation | list | 0% |
| Subfunction | list | save |
| Scene number | list | 1 |
| Value for short key - Object 1 | list | on |
| Send Value | list | 1Byte Percent value [0…100%] |
| 1Byte percent value | list | 0% |
| Value for long key - Object 2 | list | nothing |
| Description of the funnction in the display | text | Funktion 2 |
| Description of menu "Time Switch" | text | Zeitschaltuhr |
| Settings for Time Switch | list | fixed via application |
| Catch up switch times on restart | list | inactive |
| Catch up switch times at time change | list | inactive |
| Catch up switch times at unlocking | list | inactive |
| Holiday function | list | inactive |
| Lock function 1 | list | for 24 hours |
| Lock function 2 | list | for 24 hours |
| Description of function "Switch" | text | Schalten |
| Description of function "Dimming" | text | Dimmen |
| Description of function "Shutter" | text | Jalousie |
| Description of function "Scenes" | text | Szenen |
| Description of function "Values" | text | Werte |
| Function 1 | list | inactive |
| Function 2 | list | inactive |
| Function 3 | list | inactive |
| Function 4 | list | inactive |
| Function 5 | list | inactive |
| Function 6 | list | inactive |
| Function 7 | list | inactive |
| Function 8 | list | inactive |
| Function 9 | list | inactive |
| Function 10 | list | inactive |
| Function 11 | list | inactive |
| Function 12 | list | inactive |
| Function 13 | list | inactive |
| Function 14 | list | inactive |
| Function 15 | list | inactive |
| Function 16 | list | inactive |
| Function 17 | list | inactive |
| Function 18 | list | inactive |
| Function 19 | list | inactive |
| Function 20 | list | inactive |
| Description of function in the display | text | Funktion 1 |
| Key function | list | send value |
| Tastenfunktion | list | send value |
| Subfunction | list | send 1Bit value (On/Off) |
| Presentation of functions | list | display in Menu and in Time Switch |
| Setting for the values | list | Day = 0 (Left button); Night = 1 (right button) |
| Value at activation of Button C | unsignedInt 0…255 | 9 |
| Value at activation of Button D | unsignedInt 0…255 | 0 |
| Value at activation of Button C | list | 0% |
| Value at activation of Button D | list | 0% |
| Value at activation of Button C | list | Comfort |
| Value at activation of Button D | list | Comfort |
| Send temperature value as | list | Setpoint |
| Setpoint value type | list | based on current setpoint |
| Min value by decrease of setpoint temperature with Button C | list | 18,0 °C |
| Max value by increase of serpoint temperature with Button D | list | 22,0 °C |
| Value at activation of Button C | list | 18,0 °C |
| Value at activation of Button D | list | 22,0 °C |
| Set point value offset via | list | 2Byte Object |
| Setpoint value offset type | list | based on current setpoint |
| Min value by decrease of setpoint temperature with Button C | list | -3,0 °C |
| Max value by increase of serpoint temperature with Button D | list | 3,0 °C |
| Value at activation of Button C | list | -3,0 °C |
| Value at activation of Button D | list | 3,0 °C |
| Bedienfunktion | list | Long=Moving / Short=Stop/Slats Open/Close |
| Unterfunktion | list | no save |
| Button C Scene number | list | 1 |
| Button D Scene number | list | 1 |
| Enable the locking of time switch | list | inactive |
| Send Vacation function for Button C cyclic | list | active |
| Send Vacation function for Button D cyclic | list | active |
| Holiday function must be activated in the "Function of Time Switch" | text | <- TIP |
| Cycle time | list | 30 min |
| Polarity of blocking function | list | Blocking at value = 1 |
| Setting weekdays | list | predifined |
| Time Switch 1 | list | inactive |
| Mode | list | depending on time |
| Hours | unsignedInt 0…23 | 0 |
| Minutes | unsignedInt 0…59 | 0 |
| Switching time move to ... minutes | signedInt -99…99 | 0 |
| Advanced function only for hardware starting from version 1.1 | text | <- TIP |
| Minute range for random event | list | +/- 10 min |
| Weekdays | list | Monday to Sunday |
| Action applies to | list | Button C |
| Time Switch 2 | list | inactive |
| Time Switch 3 | list | inactive |
| Time Switch 4 | list | inactive |
| Time Switch 5 | list | inactive |
| Time Switch 6 | list | inactive |
| Manual input on the display is limited for hardware to version 1.4 | text | <- TIP |
| Monday | list | inactive |
| Tuesday | list | inactive |
| Wednesday | list | inactive |
| Thursday | list | inactive |
| Friday | list | inactive |
| Saturday | list | inactive |
| Sunday | list | inactive |
| Description of function in the display | text | Funktion 2 |
| Presentation of functions | list | display only in Menu |
| Description of function in the display | text | Funktion 3 |
| Action applies to | list | Button D |
| Description of function in the display | text | Funktion 4 |
| Description of function in the display | text | Funktion 5 |
| Description of function in the display | text | Funktion 6 |
| Description of function in the display | text | Funktion 7 |
| Description of function in the display | text | Funktion 8 |
| Description of function in the display | text | Funktion 9 |
| Description of function in the display | text | Funktion 10 |
| Description of function in the display | text | Funktion 11 |
| Description of function in the display | text | Funktion 12 |
| Description of function in the display | text | Funktion 13 |
| Description of function in the display | text | Funktion 14 |
| Description of function in the display | text | Funktion 15 |
| Description of function in the display | text | Funktion 16 |
| Description of function in the display | text | Funktion 17 |
| Description of function in the display | text | Funktion 18 |
| Description of function in the display | text | Funktion 19 |
| Description of function in the display | text | Funktion 20 |
| Query logic objects after reset | list | active |
| Setting Logic A | list | switched off |
| Object type for logic output | list | Switch |
| Send condition | list | not automatically |
| Invert output | list | no |
| Scene number | list | 2 |
| 1Byte Value | unsignedInt 0…255 | 0 |
| Input logic 1 | list | active normal |
| Input logic 2 | list | active normal |
| Input logic 3 | list | active normal |
| Input logic 4 | list | active normal |
| Setting Logic B | list | switched off |
| Setting Logic C | list | switched off |
| Setting Logic D | list | switched off |
| Setting Logic E | list | switched off |
| Setting Logic F | list | switched off |
| Setting Logic G | list | switched off |
| Setting Logic H | list | switched off |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Glass Central Operation Unit 1.3 latest | $0048 | F256 | 2026-11-25 | 415 KB | Download |
About this file
This is the official ETS product database for the MDT technologies GmbH Glass Central Operation Unit with LCD (SCN-LCDGx.01), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from MDT technologies GmbH
- BE-BZS86.01 Central Operation Unit Smart 86 BE-BZS86.01
- BE-GBZx.01 Glass Central Operation Unit Smart BE-GBZx.01
- SCN-CO2M601x.02 CO2 / VOC Combi Sensor 60 CH SCN-CO2M601x.02
- SCN-CO2MGS.02 CO2 / VOC Combi Sensor 55 SCN-CO2MGS.02
- SCN-KP360K3.03 Combi-Presence Detector 360° with room climate sensors SCN-KP360K3.03
- Analog I/O 2fold, flush mounted AIO-0210V.01
- Analog I/O 4fold, MDRC AIO-0410V.01
- AKD-0103.01 Dimming actuator 1-f, 4TE, 230VAC,600W AKD-0103.01
- AKD-0201.01 Dimming actuator 2-f, 4TE, 230VAC,250W AKD-0201.01
- AKD-0201.02 Dimming Actuator 2-fold AKD-0201.02
- AKD-0203.01 Dimming actuator 2-f, 8TE, 230VAC,600W AKD-0203.01
- AKD-0224V.01 LED Controller 2 channel AKD-0224V.01