Ekinex S.p.A. · Order number EK-HU1-TP · Heating, cooling and ventilation

Office Controller

Download .knxprod APEKHU1TP 0.1 · 359 KB

Product

ManufacturerEkinex S.p.A.
Product nameOffice Controller
Order numberEK-HU1-TP
HardwareOffice Controller
MediumTwisted Pair
Bus current (mA)15
Rail mountedYes
Width (mm)144
RegistrationRegistered · 2019-04-15
Languagesen-US, de-DE, fr-FR, it-IT
Catalog entryM-00B6_H-00B600000037-1_HP-4855-01-C2A3_CI-EK.2DHU1.2DTP-2
FingerprintC2A3
SHA-25654e4cd2b4b255ab8c8a27544bd614944c1a6d430703796253d739897e8f84609
First seen2026-11-25
Markets69 markets

Application program: APEKHU1TP 0.1

Application number$4855
Version0.1
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version4.0
Parameters2622
Group objects718
Group objects (718)
NoNameFunctionSizeDPTFlags
1Manual mode active1 Bit1.3 enableCRT
2Disable front pushbuttons1 Bit1.2 booleanCW
3Technical alarm1 Bit1.5 alarmCRT
4Communication alarm1 Bit1.5 alarmCRT
5Device power off alarm1 Bit1.5 alarmCRT
6Thermal generator lock alarm1 Bit1.5 alarmCW
7Temperature control alarm1 Bit1.5 alarmCRT
8Filter change warning1 Bit1.5 alarmCRWTU
9Drip tray status1 Bit1.5 alarmCRWTU
10Alarm text14 Bytes16.0 Character String (ASCII)CRT
11Input AI1 - Temperature value2 Bytes9.1 temperature (°C)CRT
12Input AI1 - Temperature threshold 1 - Switch1 Bit1.1 switchCRT
13Input AI1 - Temperature threshold 2 - Switch1 Bit1.1 switchCRT
14Input AI1 - Temperature threshold 1 - Value2 Bytes9.1 temperature (°C)CRWTU
15Input AI1 - Temperature threshold 2 - Value2 Bytes9.1 temperature (°C)CRWTU
16Input AI2 - Temperature value2 Bytes9.1 temperature (°C)CRT
17Input AI2 - Temperature threshold 1 - Switch1 Bit1.1 switchCRT
18Input AI2 - Temperature threshold 2 - Switch1 Bit1.1 switchCRT
19Input AI2 - Temperature threshold 1 - Value2 Bytes9.1 temperature (°C)CRWTU
20Input AI2 - Temperature threshold 2 - Value2 Bytes9.1 temperature (°C)CRWTU
21Input BI1 - Lock command1 Bit1.3 enableCWU
21Inputs BI1 and BI2 - Lock command1 Bit1.3 enableCWU
22Input BI1 - Switching status 1-bit object 11 Bit1.1 switchCRWTU
22Input BI1 - Switching status 2-bits object 12 Bit2.1 switch controlCRWTU
22Input BI1 - Switching status 1-unsigned byte object 11 Byte5.1 percentage (0..100%)CRWTU
22Input BI1 - Switching status 1-signed byte object 11 Byte6.1 percentage (-128..127%)CRWTU
22Input BI1 - Switching status 2-unsigned bytes object 12 Bytes7.1 pulsesCRWTU
22Input BI1 - Switching status 2-signed bytes object 12 Bytes8.1 pulses differenceCRWTU
22Input BI1 - Switching status 2-bytes floating value object 12 Bytes9.1 temperature (°C)CRWTU
23Input BI1 - Switching status 1-bit object 21 Bit1.1 switchCRWTU
23Input BI1 - Switching status 2-bits object 22 Bit2.1 switch controlCRWTU
23Input BI1 - Switching status 1-unsigned byte object 21 Byte5.1 percentage (0..100%)CRWTU
23Input BI1 - Switching status 1-signed byte object 21 Byte6.1 percentage (-128..127%)CRWTU
23Input BI1 - Switching status 2-unsigned bytes object 22 Bytes7.1 pulsesCRWTU
23Input BI1 - Switching status 2-signed bytes object 22 Bytes8.1 pulses differenceCRWTU
23Input BI1 - Switching status 2-bytes floating value object 22 Bytes9.1 temperature (°C)CRWTU
24Input BI1 - Switching status 1-bit object 31 Bit1.1 switchCRWTU
24Input BI1 - Switching status 2-bits object 32 Bit2.1 switch controlCRWTU
24Input BI1 - Switching status 1-unsigned byte object 31 Byte5.1 percentage (0..100%)CRWTU
24Input BI1 - Switching status 1-signed byte object 31 Byte6.1 percentage (-128..127%)CRWTU
24Input BI1 - Switching status 2-unsigned bytes object 32 Bytes7.1 pulsesCRWTU
24Input BI1 - Switching status 2-signed bytes object 32 Bytes8.1 pulses differenceCRWTU
24Input BI1 - Switching status 2-bytes floating value object 32 Bytes9.1 temperature (°C)CRWTU
25Input BI1 - Switching status 1-bit object 41 Bit1.1 switchCRWTU
25Input BI1 - Switching status 2-bits object 42 Bit2.1 switch controlCRWTU
25Input BI1 - Switching status 1-unsigned byte object 41 Byte5.1 percentage (0..100%)CRWTU
25Input BI1 - Switching status 1-signed byte object 41 Byte6.1 percentage (-128..127%)CRWTU
25Input BI1 - Switching status 2-unsigned bytes object 42 Bytes7.1 pulsesCRWTU
25Input BI1 - Switching status 2-signed bytes object 42 Bytes8.1 pulses differenceCRWTU
25Input BI1 - Switching status 2-bytes floating value object 42 Bytes9.1 temperature (°C)CRWTU
26Input BI1 - Switching status 1-bit object 51 Bit1.1 switchCRWTU
26Input BI1 - Switching status 2-bits object 52 Bit2.1 switch controlCRWTU
26Input BI1 - Switching status 1-unsigned byte object 51 Byte5.1 percentage (0..100%)CRWTU
26Input BI1 - Switching status 1-signed byte object 51 Byte6.1 percentage (-128..127%)CRWTU
26Input BI1 - Switching status 2-unsigned bytes object 52 Bytes7.1 pulsesCRWTU
26Input BI1 - Switching status 2-signed bytes object 52 Bytes8.1 pulses differenceCRWTU
26Input BI1 - Switching status 2-bytes floating value object 52 Bytes9.1 temperature (°C)CRWTU
27Input BI1 - Switching status 1-bit object 61 Bit1.1 switchCRWTU
27Input BI1 - Switching status 2-bits object 62 Bit2.1 switch controlCRWTU
27Input BI1 - Switching status 1-unsigned byte object 61 Byte5.1 percentage (0..100%)CRWTU
27Input BI1 - Switching status 1-signed byte object 61 Byte6.1 percentage (-128..127%)CRWTU
27Input BI1 - Switching status 2-unsigned bytes object 62 Bytes7.1 pulsesCRWTU
27Input BI1 - Switching status 2-signed bytes object 62 Bytes8.1 pulses differenceCRWTU
27Input BI1 - Switching status 2-bytes floating value object 62 Bytes9.1 temperature (°C)CRWTU
28Input BI1 - Switching status 1-bit object 71 Bit1.1 switchCRWTU
28Input BI1 - Switching status 2-bits object 72 Bit2.1 switch controlCRWTU
28Input BI1 - Switching status 1-unsigned byte object 71 Byte5.1 percentage (0..100%)CRWTU
28Input BI1 - Switching status 1-signed byte object 71 Byte6.1 percentage (-128..127%)CRWTU
28Input BI1 - Switching status 2-unsigned bytes object 72 Bytes7.1 pulsesCRWTU
28Input BI1 - Switching status 2-signed bytes object 72 Bytes8.1 pulses differenceCRWTU
28Input BI1 - Switching status 2-bytes floating value object 72 Bytes9.1 temperature (°C)CRWTU
29Input BI1 - Switching status 1-bit object 81 Bit1.1 switchCRWTU
29Input BI1 - Switching status 2-bits object 82 Bit2.1 switch controlCRWTU
29Input BI1 - Switching status 1-unsigned byte object 81 Byte5.1 percentage (0..100%)CRWTU
29Input BI1 - Switching status 1-signed byte object 81 Byte6.1 percentage (-128..127%)CRWTU
29Input BI1 - Switching status 2-unsigned bytes object 82 Bytes7.1 pulsesCRWTU
29Input BI1 - Switching status 2-signed bytes object 82 Bytes8.1 pulses differenceCRWTU
29Input BI1 - Switching status 2-bytes floating value object 82 Bytes9.1 temperature (°C)CRWTU
30Input BI1 - Switching command1 Bit1.1 switchCWTU
30Input BI1 - Dedicated stop command1 Bit1.17 triggerCT
30Inputs BI1 and BI2 - Switching command1 Bit1.1 switchCWTU
30Inputs BI1 and BI2 - Dedicated stop command1 Bit1.17 triggerCT
31Inputs BI1 and BI2 - Dimming up / down / stop command4 Bit3.7 dimming controlCT
31Input BI1 - Dimming up / down / stop command4 Bit3.7 dimming controlCT
32Input BI1 - Stop-step up / down command1 Bit1.7 stepCT
32Inputs BI1 and BI2 - Stop-step up / down command1 Bit1.7 stepCT
33Inputs BI1 and BI2 - Move up / down command1 Bit1.8 up/downCT
33Input BI1 - Move up / down command1 Bit1.8 up/downCT
34Input BI1 - Scene number1 Byte17.1 scene numberCT
35Input BI2 - Lock command1 Bit1.3 enableCWU
36Input BI2 - Switching status 1-bit object 11 Bit1.1 switchCRWTU
36Input BI2 - Switching status 2-bits object 12 Bit2.1 switch controlCRWTU
36Input BI2 - Switching status 1-unsigned byte object 11 Byte5.1 percentage (0..100%)CRWTU
36Input BI2 - Switching status 1-signed byte object 11 Byte6.1 percentage (-128..127%)CRWTU
36Input BI2 - Switching status 2-unsigned bytes object 12 Bytes7.1 pulsesCRWTU
36Input BI2 - Switching status 2-signed bytes object 12 Bytes8.1 pulses differenceCRWTU
36Input BI2 - Switching status 2-bytes floating value object 12 Bytes9.1 temperature (°C)CRWTU
37Input BI2 - Switching status 1-bit object 21 Bit1.1 switchCRWTU
37Input BI2 - Switching status 2-bits object 22 Bit2.1 switch controlCRWTU
37Input BI2 - Switching status 1-unsigned byte object 21 Byte5.1 percentage (0..100%)CRWTU
37Input BI2 - Switching status 1-signed byte object 21 Byte6.1 percentage (-128..127%)CRWTU
37Input BI2 - Switching status 2-unsigned bytes object 22 Bytes7.1 pulsesCRWTU
37Input BI2 - Switching status 2-signed bytes object 22 Bytes8.1 pulses differenceCRWTU
37Input BI2 - Switching status 2-bytes floating value object 22 Bytes9.1 temperature (°C)CRWTU
38Input BI2 - Switching status 1-bit object 31 Bit1.1 switchCRWTU
38Input BI2 - Switching status 2-bits object 32 Bit2.1 switch controlCRWTU
38Input BI2 - Switching status 1-unsigned byte object 31 Byte5.1 percentage (0..100%)CRWTU
38Input BI2 - Switching status 1-signed byte object 31 Byte6.1 percentage (-128..127%)CRWTU
38Input BI2 - Switching status 2-unsigned bytes object 32 Bytes7.1 pulsesCRWTU
38Input BI2 - Switching status 2-signed bytes object 32 Bytes8.1 pulses differenceCRWTU
38Input BI2 - Switching status 2-bytes floating value object 32 Bytes9.1 temperature (°C)CRWTU
39Input BI2 - Switching status 1-bit object 41 Bit1.1 switchCRWTU
39Input BI2 - Switching status 2-bits object 42 Bit2.1 switch controlCRWTU
39Input BI2 - Switching status 1-unsigned byte object 41 Byte5.1 percentage (0..100%)CRWTU
39Input BI2 - Switching status 1-signed byte object 41 Byte6.1 percentage (-128..127%)CRWTU
39Input BI2 - Switching status 2-unsigned bytes object 42 Bytes7.1 pulsesCRWTU
39Input BI2 - Switching status 2-signed bytes object 42 Bytes8.1 pulses differenceCRWTU
39Input BI2 - Switching status 2-bytes floating value object 42 Bytes9.1 temperature (°C)CRWTU
40Input BI2 - Switching status 1-bit object 51 Bit1.1 switchCRWTU
40Input BI2 - Switching status 2-bits object 52 Bit2.1 switch controlCRWTU
40Input BI2 - Switching status 1-unsigned byte object 51 Byte5.1 percentage (0..100%)CRWTU
40Input BI2 - Switching status 1-signed byte object 51 Byte6.1 percentage (-128..127%)CRWTU
40Input BI2 - Switching status 2-unsigned bytes object 52 Bytes7.1 pulsesCRWTU
40Input BI2 - Switching status 2-signed bytes object 52 Bytes8.1 pulses differenceCRWTU
40Input BI2 - Switching status 2-bytes floating value object 52 Bytes9.1 temperature (°C)CRWTU
41Input BI2 - Switching status 1-bit object 61 Bit1.1 switchCRWTU
41Input BI2 - Switching status 2-bits object 62 Bit2.1 switch controlCRWTU
41Input BI2 - Switching status 1-unsigned byte object 61 Byte5.1 percentage (0..100%)CRWTU
41Input BI2 - Switching status 1-signed byte object 61 Byte6.1 percentage (-128..127%)CRWTU
41Input BI2 - Switching status 2-unsigned bytes object 62 Bytes7.1 pulsesCRWTU
41Input BI2 - Switching status 2-signed bytes object 62 Bytes8.1 pulses differenceCRWTU
41Input BI2 - Switching status 2-bytes floating value object 62 Bytes9.1 temperature (°C)CRWTU
42Input BI2 - Switching status 1-bit object 71 Bit1.1 switchCRWTU
42Input BI2 - Switching status 2-bits object 72 Bit2.1 switch controlCRWTU
42Input BI2 - Switching status 1-unsigned byte object 71 Byte5.1 percentage (0..100%)CRWTU
42Input BI2 - Switching status 1-signed byte object 71 Byte6.1 percentage (-128..127%)CRWTU
42Input BI2 - Switching status 2-unsigned bytes object 72 Bytes7.1 pulsesCRWTU
42Input BI2 - Switching status 2-signed bytes object 72 Bytes8.1 pulses differenceCRWTU
42Input BI2 - Switching status 2-bytes floating value object 72 Bytes9.1 temperature (°C)CRWTU
43Input BI2 - Switching status 1-bit object 81 Bit1.1 switchCRWTU
43Input BI2 - Switching status 2-bits object 82 Bit2.1 switch controlCRWTU
43Input BI2 - Switching status 1-unsigned byte object 81 Byte5.1 percentage (0..100%)CRWTU
43Input BI2 - Switching status 1-signed byte object 81 Byte6.1 percentage (-128..127%)CRWTU
43Input BI2 - Switching status 2-unsigned bytes object 82 Bytes7.1 pulsesCRWTU
43Input BI2 - Switching status 2-signed bytes object 82 Bytes8.1 pulses differenceCRWTU
43Input BI2 - Switching status 2-bytes floating value object 82 Bytes9.1 temperature (°C)CRWTU
44Input BI2 - Switching command1 Bit1.1 switchCWTU
44Input BI2 - Dedicated stop command1 Bit1.17 triggerCT
45Input BI2 - Dimming up / down / stop command4 Bit3.7 dimming controlCT
46Input BI2 - Stop-step up / down command1 Bit1.7 stepCT
47Input BI2 - Move up / down command1 Bit1.8 up/downCT
48Input BI2 - Scene number1 Byte17.1 scene numberCT
49Input BI3 - Lock command1 Bit1.3 enableCWU
49Inputs BI3 and BI4 - Lock command1 Bit1.3 enableCWU
50Input BI3 - Switching status 1-bit object 11 Bit1.1 switchCRWTU
50Input BI3 - Switching status 2-bits object 12 Bit2.1 switch controlCRWTU
50Input BI3 - Switching status 1-unsigned byte object 11 Byte5.1 percentage (0..100%)CRWTU
50Input BI3 - Switching status 1-signed byte object 11 Byte6.1 percentage (-128..127%)CRWTU
50Input BI3 - Switching status 2-unsigned bytes object 12 Bytes7.1 pulsesCRWTU
50Input BI3 - Switching status 2-signed bytes object 12 Bytes8.1 pulses differenceCRWTU
50Input BI3 - Switching status 2-bytes floating value object 12 Bytes9.1 temperature (°C)CRWTU
51Input BI3 - Switching status 1-bit object 21 Bit1.1 switchCRWTU
51Input BI3 - Switching status 2-bits object 22 Bit2.1 switch controlCRWTU
51Input BI3 - Switching status 1-unsigned byte object 21 Byte5.1 percentage (0..100%)CRWTU
51Input BI3 - Switching status 1-signed byte object 21 Byte6.1 percentage (-128..127%)CRWTU
51Input BI3 - Switching status 2-unsigned bytes object 22 Bytes7.1 pulsesCRWTU
51Input BI3 - Switching status 2-signed bytes object 22 Bytes8.1 pulses differenceCRWTU
51Input BI3 - Switching status 2-bytes floating value object 22 Bytes9.1 temperature (°C)CRWTU
52Input BI3 - Switching status 1-bit object 31 Bit1.1 switchCRWTU
52Input BI3 - Switching status 2-bits object 32 Bit2.1 switch controlCRWTU
52Input BI3 - Switching status 1-unsigned byte object 31 Byte5.1 percentage (0..100%)CRWTU
52Input BI3 - Switching status 1-signed byte object 31 Byte6.1 percentage (-128..127%)CRWTU
52Input BI3 - Switching status 2-unsigned bytes object 32 Bytes7.1 pulsesCRWTU
52Input BI3 - Switching status 2-signed bytes object 32 Bytes8.1 pulses differenceCRWTU
52Input BI3 - Switching status 2-bytes floating value object 32 Bytes9.1 temperature (°C)CRWTU
53Input BI3 - Switching status 1-bit object 41 Bit1.1 switchCRWTU
53Input BI3 - Switching status 2-bits object 42 Bit2.1 switch controlCRWTU
53Input BI3 - Switching status 1-unsigned byte object 41 Byte5.1 percentage (0..100%)CRWTU
53Input BI3 - Switching status 1-signed byte object 41 Byte6.1 percentage (-128..127%)CRWTU
53Input BI3 - Switching status 2-unsigned bytes object 42 Bytes7.1 pulsesCRWTU
53Input BI3 - Switching status 2-signed bytes object 42 Bytes8.1 pulses differenceCRWTU
53Input BI3 - Switching status 2-bytes floating value object 42 Bytes9.1 temperature (°C)CRWTU
54Input BI3 - Switching status 1-bit object 51 Bit1.1 switchCRWTU
54Input BI3 - Switching status 2-bits object 52 Bit2.1 switch controlCRWTU
54Input BI3 - Switching status 1-unsigned byte object 51 Byte5.1 percentage (0..100%)CRWTU
54Input BI3 - Switching status 1-signed byte object 51 Byte6.1 percentage (-128..127%)CRWTU
54Input BI3 - Switching status 2-unsigned bytes object 52 Bytes7.1 pulsesCRWTU
54Input BI3 - Switching status 2-signed bytes object 52 Bytes8.1 pulses differenceCRWTU
54Input BI3 - Switching status 2-bytes floating value object 52 Bytes9.1 temperature (°C)CRWTU
55Input BI3 - Switching status 1-bit object 61 Bit1.1 switchCRWTU
55Input BI3 - Switching status 2-bits object 62 Bit2.1 switch controlCRWTU
55Input BI3 - Switching status 1-unsigned byte object 61 Byte5.1 percentage (0..100%)CRWTU
55Input BI3 - Switching status 1-signed byte object 61 Byte6.1 percentage (-128..127%)CRWTU
55Input BI3 - Switching status 2-unsigned bytes object 62 Bytes7.1 pulsesCRWTU
55Input BI3 - Switching status 2-signed bytes object 62 Bytes8.1 pulses differenceCRWTU
55Input BI3 - Switching status 2-bytes floating value object 62 Bytes9.1 temperature (°C)CRWTU
56Input BI3 - Switching status 1-bit object 71 Bit1.1 switchCRWTU
56Input BI3 - Switching status 2-bits object 72 Bit2.1 switch controlCRWTU
56Input BI3 - Switching status 1-unsigned byte object 71 Byte5.1 percentage (0..100%)CRWTU
56Input BI3 - Switching status 1-signed byte object 71 Byte6.1 percentage (-128..127%)CRWTU
56Input BI3 - Switching status 2-unsigned bytes object 72 Bytes7.1 pulsesCRWTU
56Input BI3 - Switching status 2-signed bytes object 72 Bytes8.1 pulses differenceCRWTU
56Input BI3 - Switching status 2-bytes floating value object 72 Bytes9.1 temperature (°C)CRWTU
57Input BI3 - Switching status 1-bit object 81 Bit1.1 switchCRWTU
57Input BI3 - Switching status 2-bits object 82 Bit2.1 switch controlCRWTU
57Input BI3 - Switching status 1-unsigned byte object 81 Byte5.1 percentage (0..100%)CRWTU
57Input BI3 - Switching status 1-signed byte object 81 Byte6.1 percentage (-128..127%)CRWTU
57Input BI3 - Switching status 2-unsigned bytes object 82 Bytes7.1 pulsesCRWTU
57Input BI3 - Switching status 2-signed bytes object 82 Bytes8.1 pulses differenceCRWTU
57Input BI3 - Switching status 2-bytes floating value object 82 Bytes9.1 temperature (°C)CRWTU
58Input BI3 - Switching command1 Bit1.1 switchCWTU
58Input BI3 - Dedicated stop command1 Bit1.17 triggerCT
58Inputs BI3 and BI4 - Switching command1 Bit1.1 switchCWTU
58Inputs BI3 and BI4 - Dedicated stop command1 Bit1.17 triggerCT
59Input BI3 - Dimming up / down / stop command4 Bit3.7 dimming controlCT
59Inputs BI3 and BI4 - Dimming up / down / stop command4 Bit3.7 dimming controlCT
60Input BI3 - Stop-step up / down command1 Bit1.7 stepCT
60Inputs BI3 and BI4 - Stop-step up / down command1 Bit1.7 stepCT
61Input BI3 - Move up / down command1 Bit1.8 up/downCT
61Inputs BI3 and BI4 - Move up / down command1 Bit1.8 up/downCT
62Input BI3 - Scene number1 Byte17.1 scene numberCT
63Input BI4 - Lock command1 Bit1.3 enableCWU
64Input BI4 - Switching status 1-bit object 11 Bit1.1 switchCRWTU
64Input BI4 - Switching status 2-bits object 12 Bit2.1 switch controlCRWTU
64Input BI4 - Switching status 1-unsigned byte object 11 Byte5.1 percentage (0..100%)CRWTU
64Input BI4 - Switching status 1-signed byte object 11 Byte6.1 percentage (-128..127%)CRWTU
64Input BI4 - Switching status 2-unsigned bytes object 12 Bytes7.1 pulsesCRWTU
64Input BI4 - Switching status 2-signed bytes object 12 Bytes8.1 pulses differenceCRWTU
64Input BI4 - Switching status 2-bytes floating value object 12 Bytes9.1 temperature (°C)CRWTU
65Input BI4 - Switching status 1-bit object 21 Bit1.1 switchCRWTU
65Input BI4 - Switching status 2-bits object 22 Bit2.1 switch controlCRWTU
65Input BI4 - Switching status 1-unsigned byte object 21 Byte5.1 percentage (0..100%)CRWTU
65Input BI4 - Switching status 1-signed byte object 21 Byte6.1 percentage (-128..127%)CRWTU
65Input BI4 - Switching status 2-unsigned bytes object 22 Bytes7.1 pulsesCRWTU
65Input BI4 - Switching status 2-signed bytes object 22 Bytes8.1 pulses differenceCRWTU
65Input BI4 - Switching status 2-bytes floating value object 22 Bytes9.1 temperature (°C)CRWTU
66Input BI4 - Switching status 1-bit object 31 Bit1.1 switchCRWTU
66Input BI4 - Switching status 2-bits object 32 Bit2.1 switch controlCRWTU
66Input BI4 - Switching status 1-unsigned byte object 31 Byte5.1 percentage (0..100%)CRWTU
66Input BI4 - Switching status 1-signed byte object 31 Byte6.1 percentage (-128..127%)CRWTU
66Input BI4 - Switching status 2-unsigned bytes object 32 Bytes7.1 pulsesCRWTU
66Input BI4 - Switching status 2-signed bytes object 32 Bytes8.1 pulses differenceCRWTU
66Input BI4 - Switching status 2-bytes floating value object 32 Bytes9.1 temperature (°C)CRWTU
67Input BI4 - Switching status 1-bit object 41 Bit1.1 switchCRWTU
67Input BI4 - Switching status 2-bits object 42 Bit2.1 switch controlCRWTU
67Input BI4 - Switching status 1-unsigned byte object 41 Byte5.1 percentage (0..100%)CRWTU
67Input BI4 - Switching status 1-signed byte object 41 Byte6.1 percentage (-128..127%)CRWTU
67Input BI4 - Switching status 2-unsigned bytes object 42 Bytes7.1 pulsesCRWTU
67Input BI4 - Switching status 2-signed bytes object 42 Bytes8.1 pulses differenceCRWTU
67Input BI4 - Switching status 2-bytes floating value object 42 Bytes9.1 temperature (°C)CRWTU
68Input BI4 - Switching status 1-bit object 51 Bit1.1 switchCRWTU
68Input BI4 - Switching status 2-bits object 52 Bit2.1 switch controlCRWTU
68Input BI4 - Switching status 1-unsigned byte object 51 Byte5.1 percentage (0..100%)CRWTU
68Input BI4 - Switching status 1-signed byte object 51 Byte6.1 percentage (-128..127%)CRWTU
68Input BI4 - Switching status 2-unsigned bytes object 52 Bytes7.1 pulsesCRWTU
68Input BI4 - Switching status 2-signed bytes object 52 Bytes8.1 pulses differenceCRWTU
68Input BI4 - Switching status 2-bytes floating value object 52 Bytes9.1 temperature (°C)CRWTU
69Input BI4 - Switching status 1-bit object 61 Bit1.1 switchCRWTU
69Input BI4 - Switching status 2-bits object 62 Bit2.1 switch controlCRWTU
69Input BI4 - Switching status 1-unsigned byte object 61 Byte5.1 percentage (0..100%)CRWTU
69Input BI4 - Switching status 1-signed byte object 61 Byte6.1 percentage (-128..127%)CRWTU
69Input BI4 - Switching status 2-unsigned bytes object 62 Bytes7.1 pulsesCRWTU
69Input BI4 - Switching status 2-signed bytes object 62 Bytes8.1 pulses differenceCRWTU
69Input BI4 - Switching status 2-bytes floating value object 62 Bytes9.1 temperature (°C)CRWTU
70Input BI4 - Switching status 1-bit object 71 Bit1.1 switchCRWTU
70Input BI4 - Switching status 2-bits object 72 Bit2.1 switch controlCRWTU
70Input BI4 - Switching status 1-unsigned byte object 71 Byte5.1 percentage (0..100%)CRWTU
70Input BI4 - Switching status 1-signed byte object 71 Byte6.1 percentage (-128..127%)CRWTU
70Input BI4 - Switching status 2-unsigned bytes object 72 Bytes7.1 pulsesCRWTU
70Input BI4 - Switching status 2-signed bytes object 72 Bytes8.1 pulses differenceCRWTU
70Input BI4 - Switching status 2-bytes floating value object 72 Bytes9.1 temperature (°C)CRWTU
71Input BI4 - Switching status 1-bit object 81 Bit1.1 switchCRWTU
71Input BI4 - Switching status 2-bits object 82 Bit2.1 switch controlCRWTU
71Input BI4 - Switching status 1-unsigned byte object 81 Byte5.1 percentage (0..100%)CRWTU
71Input BI4 - Switching status 1-signed byte object 81 Byte6.1 percentage (-128..127%)CRWTU
71Input BI4 - Switching status 2-unsigned bytes object 82 Bytes7.1 pulsesCRWTU
71Input BI4 - Switching status 2-signed bytes object 82 Bytes8.1 pulses differenceCRWTU
71Input BI4 - Switching status 2-bytes floating value object 82 Bytes9.1 temperature (°C)CRWTU
72Input BI4 - Switching command1 Bit1.1 switchCWTU
72Input BI4 - Dedicated stop command1 Bit1.17 triggerCT
73Input BI4 - Dimming up / down / stop command4 Bit3.7 dimming controlCT
74Input BI4 - Stop-step up / down command1 Bit1.7 stepCT
75Input BI4 - Move up / down command1 Bit1.8 up/downCT
76Input BI4 - Scene number1 Byte17.1 scene numberCT
77Input BI5 - Lock command1 Bit1.3 enableCWU
77Inputs BI5 and BI6 - Lock command1 Bit1.3 enableCWU
78Input BI5 - Switching status 1-bit object 11 Bit1.1 switchCRWTU
78Input BI5 - Switching status 2-bits object 12 Bit2.1 switch controlCRWTU
78Input BI5 - Switching status 1-unsigned byte object 11 Byte5.1 percentage (0..100%)CRWTU
78Input BI5 - Switching status 1-signed byte object 11 Byte6.1 percentage (-128..127%)CRWTU
78Input BI5 - Switching status 2-unsigned bytes object 12 Bytes7.1 pulsesCRWTU
78Input BI5 - Switching status 2-signed bytes object 12 Bytes8.1 pulses differenceCRWTU
78Input BI5 - Switching status 2-bytes floating value object 12 Bytes9.1 temperature (°C)CRWTU
79Input BI5 - Switching status 1-bit object 21 Bit1.1 switchCRWTU
79Input BI5 - Switching status 2-bits object 22 Bit2.1 switch controlCRWTU
79Input BI5 - Switching status 1-unsigned byte object 21 Byte5.1 percentage (0..100%)CRWTU
79Input BI5 - Switching status 1-signed byte object 21 Byte6.1 percentage (-128..127%)CRWTU
79Input BI5 - Switching status 2-unsigned bytes object 22 Bytes7.1 pulsesCRWTU
79Input BI5 - Switching status 2-signed bytes object 22 Bytes8.1 pulses differenceCRWTU
79Input BI5 - Switching status 2-bytes floating value object 22 Bytes9.1 temperature (°C)CRWTU
80Input BI5 - Switching status 1-bit object 31 Bit1.1 switchCRWTU
80Input BI5 - Switching status 2-bits object 32 Bit2.1 switch controlCRWTU
80Input BI5 - Switching status 1-unsigned byte object 31 Byte5.1 percentage (0..100%)CRWTU
80Input BI5 - Switching status 1-signed byte object 31 Byte6.1 percentage (-128..127%)CRWTU
80Input BI5 - Switching status 2-unsigned bytes object 32 Bytes7.1 pulsesCRWTU
80Input BI5 - Switching status 2-signed bytes object 32 Bytes8.1 pulses differenceCRWTU
80Input BI5 - Switching status 2-bytes floating value object 32 Bytes9.1 temperature (°C)CRWTU
81Input BI5 - Switching status 1-bit object 41 Bit1.1 switchCRWTU
81Input BI5 - Switching status 2-bits object 42 Bit2.1 switch controlCRWTU
81Input BI5 - Switching status 1-unsigned byte object 41 Byte5.1 percentage (0..100%)CRWTU
81Input BI5 - Switching status 1-signed byte object 41 Byte6.1 percentage (-128..127%)CRWTU
81Input BI5 - Switching status 2-unsigned bytes object 42 Bytes7.1 pulsesCRWTU
81Input BI5 - Switching status 2-signed bytes object 42 Bytes8.1 pulses differenceCRWTU
81Input BI5 - Switching status 2-bytes floating value object 42 Bytes9.1 temperature (°C)CRWTU
82Input BI5 - Switching status 1-bit object 51 Bit1.1 switchCRWTU
82Input BI5 - Switching status 2-bits object 52 Bit2.1 switch controlCRWTU
82Input BI5 - Switching status 1-unsigned byte object 51 Byte5.1 percentage (0..100%)CRWTU
82Input BI5 - Switching status 1-signed byte object 51 Byte6.1 percentage (-128..127%)CRWTU
82Input BI5 - Switching status 2-unsigned bytes object 52 Bytes7.1 pulsesCRWTU
82Input BI5 - Switching status 2-signed bytes object 52 Bytes8.1 pulses differenceCRWTU
82Input BI5 - Switching status 2-bytes floating value object 52 Bytes9.1 temperature (°C)CRWTU
83Input BI5 - Switching status 1-bit object 61 Bit1.1 switchCRWTU
83Input BI5 - Switching status 2-bits object 62 Bit2.1 switch controlCRWTU
83Input BI5 - Switching status 1-unsigned byte object 61 Byte5.1 percentage (0..100%)CRWTU
83Input BI5 - Switching status 1-signed byte object 61 Byte6.1 percentage (-128..127%)CRWTU
83Input BI5 - Switching status 2-unsigned bytes object 62 Bytes7.1 pulsesCRWTU
83Input BI5 - Switching status 2-signed bytes object 62 Bytes8.1 pulses differenceCRWTU
83Input BI5 - Switching status 2-bytes floating value object 62 Bytes9.1 temperature (°C)CRWTU
84Input BI5 - Switching status 1-bit object 71 Bit1.1 switchCRWTU
84Input BI5 - Switching status 2-bits object 72 Bit2.1 switch controlCRWTU
84Input BI5 - Switching status 1-unsigned byte object 71 Byte5.1 percentage (0..100%)CRWTU
84Input BI5 - Switching status 1-signed byte object 71 Byte6.1 percentage (-128..127%)CRWTU
84Input BI5 - Switching status 2-unsigned bytes object 72 Bytes7.1 pulsesCRWTU
84Input BI5 - Switching status 2-signed bytes object 72 Bytes8.1 pulses differenceCRWTU
84Input BI5 - Switching status 2-bytes floating value object 72 Bytes9.1 temperature (°C)CRWTU
85Input BI5 - Switching status 1-bit object 81 Bit1.1 switchCRWTU
85Input BI5 - Switching status 2-bits object 82 Bit2.1 switch controlCRWTU
85Input BI5 - Switching status 1-unsigned byte object 81 Byte5.1 percentage (0..100%)CRWTU
85Input BI5 - Switching status 1-signed byte object 81 Byte6.1 percentage (-128..127%)CRWTU
85Input BI5 - Switching status 2-unsigned bytes object 82 Bytes7.1 pulsesCRWTU
85Input BI5 - Switching status 2-signed bytes object 82 Bytes8.1 pulses differenceCRWTU
85Input BI5 - Switching status 2-bytes floating value object 82 Bytes9.1 temperature (°C)CRWTU
86Input BI5 - Switching command1 Bit1.1 switchCWTU
86Input BI5 - Dedicated stop command1 Bit1.17 triggerCT
86Inputs BI5 and BI6 - Switching command1 Bit1.1 switchCWTU
86Inputs BI5 and BI6 - Dedicated stop command1 Bit1.17 triggerCT
87Input BI5 - Dimming up / down / stop command4 Bit3.7 dimming controlCT
87Inputs BI5 and BI6 - Dimming up / down / stop command4 Bit3.7 dimming controlCT
88Input BI5 - Stop-step up / down command1 Bit1.7 stepCT
88Inputs BI5 and BI6 - Stop-step up / down command1 Bit1.7 stepCT
89Input BI5 - Move up / down command1 Bit1.8 up/downCT
89Inputs BI5 and BI6 - Move up / down command1 Bit1.8 up/downCT
90Input BI5 - Scene number1 Byte17.1 scene numberCT
91Input BI6 - Lock command1 Bit1.3 enableCWU
92Input BI6 - Switching status 1-bit object 11 Bit1.1 switchCRWTU
92Input BI6 - Switching status 2-bits object 12 Bit2.1 switch controlCRWTU
92Input BI6 - Switching status 1-unsigned byte object 11 Byte5.1 percentage (0..100%)CRWTU
92Input BI6 - Switching status 1-signed byte object 11 Byte6.1 percentage (-128..127%)CRWTU
92Input BI6 - Switching status 2-unsigned bytes object 12 Bytes7.1 pulsesCRWTU
92Input BI6 - Switching status 2-signed bytes object 12 Bytes8.1 pulses differenceCRWTU
92Input BI6 - Switching status 2-bytes floating value object 12 Bytes9.1 temperature (°C)CRWTU
93Input BI6 - Switching status 1-bit object 21 Bit1.1 switchCRWTU
93Input BI6 - Switching status 2-bits object 22 Bit2.1 switch controlCRWTU
93Input BI6 - Switching status 1-unsigned byte object 21 Byte5.1 percentage (0..100%)CRWTU
93Input BI6 - Switching status 1-signed byte object 21 Byte6.1 percentage (-128..127%)CRWTU
93Input BI6 - Switching status 2-unsigned bytes object 22 Bytes7.1 pulsesCRWTU
93Input BI6 - Switching status 2-signed bytes object 22 Bytes8.1 pulses differenceCRWTU
93Input BI6 - Switching status 2-bytes floating value object 22 Bytes9.1 temperature (°C)CRWTU
94Input BI6 - Switching status 1-bit object 31 Bit1.1 switchCRWTU
94Input BI6 - Switching status 2-bits object 32 Bit2.1 switch controlCRWTU
94Input BI6 - Switching status 1-unsigned byte object 31 Byte5.1 percentage (0..100%)CRWTU
94Input BI6 - Switching status 1-signed byte object 31 Byte6.1 percentage (-128..127%)CRWTU
94Input BI6 - Switching status 2-unsigned bytes object 32 Bytes7.1 pulsesCRWTU
94Input BI6 - Switching status 2-signed bytes object 32 Bytes8.1 pulses differenceCRWTU
94Input BI6 - Switching status 2-bytes floating value object 32 Bytes9.1 temperature (°C)CRWTU
95Input BI6 - Switching status 1-bit object 41 Bit1.1 switchCRWTU
95Input BI6 - Switching status 2-bits object 42 Bit2.1 switch controlCRWTU
95Input BI6 - Switching status 1-unsigned byte object 41 Byte5.1 percentage (0..100%)CRWTU
95Input BI6 - Switching status 1-signed byte object 41 Byte6.1 percentage (-128..127%)CRWTU
95Input BI6 - Switching status 2-unsigned bytes object 42 Bytes7.1 pulsesCRWTU
95Input BI6 - Switching status 2-signed bytes object 42 Bytes8.1 pulses differenceCRWTU
95Input BI6 - Switching status 2-bytes floating value object 42 Bytes9.1 temperature (°C)CRWTU
96Input BI6 - Switching status 1-bit object 51 Bit1.1 switchCRWTU
96Input BI6 - Switching status 2-bits object 52 Bit2.1 switch controlCRWTU
96Input BI6 - Switching status 1-unsigned byte object 51 Byte5.1 percentage (0..100%)CRWTU
96Input BI6 - Switching status 1-signed byte object 51 Byte6.1 percentage (-128..127%)CRWTU
96Input BI6 - Switching status 2-unsigned bytes object 52 Bytes7.1 pulsesCRWTU
96Input BI6 - Switching status 2-signed bytes object 52 Bytes8.1 pulses differenceCRWTU
96Input BI6 - Switching status 2-bytes floating value object 52 Bytes9.1 temperature (°C)CRWTU
97Input BI6 - Switching status 1-bit object 61 Bit1.1 switchCRWTU
97Input BI6 - Switching status 2-bits object 62 Bit2.1 switch controlCRWTU
97Input BI6 - Switching status 1-unsigned byte object 61 Byte5.1 percentage (0..100%)CRWTU
97Input BI6 - Switching status 1-signed byte object 61 Byte6.1 percentage (-128..127%)CRWTU
97Input BI6 - Switching status 2-unsigned bytes object 62 Bytes7.1 pulsesCRWTU
97Input BI6 - Switching status 2-signed bytes object 62 Bytes8.1 pulses differenceCRWTU
97Input BI6 - Switching status 2-bytes floating value object 62 Bytes9.1 temperature (°C)CRWTU
98Input BI6 - Switching status 1-bit object 71 Bit1.1 switchCRWTU
98Input BI6 - Switching status 2-bits object 72 Bit2.1 switch controlCRWTU
98Input BI6 - Switching status 1-unsigned byte object 71 Byte5.1 percentage (0..100%)CRWTU
98Input BI6 - Switching status 1-signed byte object 71 Byte6.1 percentage (-128..127%)CRWTU
98Input BI6 - Switching status 2-unsigned bytes object 72 Bytes7.1 pulsesCRWTU
98Input BI6 - Switching status 2-signed bytes object 72 Bytes8.1 pulses differenceCRWTU
98Input BI6 - Switching status 2-bytes floating value object 72 Bytes9.1 temperature (°C)CRWTU
99Input BI6 - Switching status 1-bit object 81 Bit1.1 switchCRWTU
99Input BI6 - Switching status 2-bits object 82 Bit2.1 switch controlCRWTU
99Input BI6 - Switching status 1-unsigned byte object 81 Byte5.1 percentage (0..100%)CRWTU
99Input BI6 - Switching status 1-signed byte object 81 Byte6.1 percentage (-128..127%)CRWTU
99Input BI6 - Switching status 2-unsigned bytes object 82 Bytes7.1 pulsesCRWTU
99Input BI6 - Switching status 2-signed bytes object 82 Bytes8.1 pulses differenceCRWTU
99Input BI6 - Switching status 2-bytes floating value object 82 Bytes9.1 temperature (°C)CRWTU
100Input BI6 - Switching command1 Bit1.1 switchCWTU
100Input BI6 - Dedicated stop command1 Bit1.17 triggerCT
101Input BI6 - Dimming up / down / stop command4 Bit3.7 dimming controlCT
102Input BI6 - Stop-step up / down command1 Bit1.7 stepCT
103Input BI6 - Move up / down command1 Bit1.8 up/downCT
104Input BI6 - Scene number1 Byte17.1 scene numberCT
105Input BI7 - Lock command1 Bit1.3 enableCWU
106Input BI7 - Switching status 1-bit object 11 Bit1.1 switchCRWTU
106Input BI7 - Switching status 2-bits object 12 Bit2.1 switch controlCRWTU
106Input BI7 - Switching status 1-unsigned byte object 11 Byte5.1 percentage (0..100%)CRWTU
106Input BI7 - Switching status 1-signed byte object 11 Byte6.1 percentage (-128..127%)CRWTU
106Input BI7 - Switching status 2-unsigned bytes object 12 Bytes7.1 pulsesCRWTU
106Input BI7 - Switching status 2-signed bytes object 12 Bytes8.1 pulses differenceCRWTU
106Input BI7 - Switching status 2-bytes floating value object 12 Bytes9.1 temperature (°C)CRWTU
107Input BI7 - Switching status 1-bit object 21 Bit1.1 switchCRWTU
107Input BI7 - Switching status 2-bits object 22 Bit2.1 switch controlCRWTU
107Input BI7 - Switching status 1-unsigned byte object 21 Byte5.1 percentage (0..100%)CRWTU
107Input BI7 - Switching status 1-signed byte object 21 Byte6.1 percentage (-128..127%)CRWTU
107Input BI7 - Switching status 2-unsigned bytes object 22 Bytes7.1 pulsesCRWTU
107Input BI7 - Switching status 2-signed bytes object 22 Bytes8.1 pulses differenceCRWTU
107Input BI7 - Switching status 2-bytes floating value object 22 Bytes9.1 temperature (°C)CRWTU
108Input BI7 - Switching status 1-bit object 31 Bit1.1 switchCRWTU
108Input BI7 - Switching status 2-bits object 32 Bit2.1 switch controlCRWTU
108Input BI7 - Switching status 1-unsigned byte object 31 Byte5.1 percentage (0..100%)CRWTU
108Input BI7 - Switching status 1-signed byte object 31 Byte6.1 percentage (-128..127%)CRWTU
108Input BI7 - Switching status 2-unsigned bytes object 32 Bytes7.1 pulsesCRWTU
108Input BI7 - Switching status 2-signed bytes object 32 Bytes8.1 pulses differenceCRWTU
108Input BI7 - Switching status 2-bytes floating value object 32 Bytes9.1 temperature (°C)CRWTU
109Input BI7 - Switching status 1-bit object 41 Bit1.1 switchCRWTU
109Input BI7 - Switching status 2-bits object 42 Bit2.1 switch controlCRWTU
109Input BI7 - Switching status 1-unsigned byte object 41 Byte5.1 percentage (0..100%)CRWTU
109Input BI7 - Switching status 1-signed byte object 41 Byte6.1 percentage (-128..127%)CRWTU
109Input BI7 - Switching status 2-unsigned bytes object 42 Bytes7.1 pulsesCRWTU
109Input BI7 - Switching status 2-signed bytes object 42 Bytes8.1 pulses differenceCRWTU
109Input BI7 - Switching status 2-bytes floating value object 42 Bytes9.1 temperature (°C)CRWTU
110Input BI7 - Switching status 1-bit object 51 Bit1.1 switchCRWTU
110Input BI7 - Switching status 2-bits object 52 Bit2.1 switch controlCRWTU
110Input BI7 - Switching status 1-unsigned byte object 51 Byte5.1 percentage (0..100%)CRWTU
110Input BI7 - Switching status 1-signed byte object 51 Byte6.1 percentage (-128..127%)CRWTU
110Input BI7 - Switching status 2-unsigned bytes object 52 Bytes7.1 pulsesCRWTU
110Input BI7 - Switching status 2-signed bytes object 52 Bytes8.1 pulses differenceCRWTU
110Input BI7 - Switching status 2-bytes floating value object 52 Bytes9.1 temperature (°C)CRWTU
111Input BI7 - Switching status 1-bit object 61 Bit1.1 switchCRWTU
111Input BI7 - Switching status 2-bits object 62 Bit2.1 switch controlCRWTU
111Input BI7 - Switching status 1-unsigned byte object 61 Byte5.1 percentage (0..100%)CRWTU
111Input BI7 - Switching status 1-signed byte object 61 Byte6.1 percentage (-128..127%)CRWTU
111Input BI7 - Switching status 2-unsigned bytes object 62 Bytes7.1 pulsesCRWTU
111Input BI7 - Switching status 2-signed bytes object 62 Bytes8.1 pulses differenceCRWTU
111Input BI7 - Switching status 2-bytes floating value object 62 Bytes9.1 temperature (°C)CRWTU
112Input BI7 - Switching status 1-bit object 71 Bit1.1 switchCRWTU
112Input BI7 - Switching status 2-bits object 72 Bit2.1 switch controlCRWTU
112Input BI7 - Switching status 1-unsigned byte object 71 Byte5.1 percentage (0..100%)CRWTU
112Input BI7 - Switching status 1-signed byte object 71 Byte6.1 percentage (-128..127%)CRWTU
112Input BI7 - Switching status 2-unsigned bytes object 72 Bytes7.1 pulsesCRWTU
112Input BI7 - Switching status 2-signed bytes object 72 Bytes8.1 pulses differenceCRWTU
112Input BI7 - Switching status 2-bytes floating value object 72 Bytes9.1 temperature (°C)CRWTU
113Input BI7 - Switching status 1-bit object 81 Bit1.1 switchCRWTU
113Input BI7 - Switching status 2-bits object 82 Bit2.1 switch controlCRWTU
113Input BI7 - Switching status 1-unsigned byte object 81 Byte5.1 percentage (0..100%)CRWTU
113Input BI7 - Switching status 1-signed byte object 81 Byte6.1 percentage (-128..127%)CRWTU
113Input BI7 - Switching status 2-unsigned bytes object 82 Bytes7.1 pulsesCRWTU
113Input BI7 - Switching status 2-signed bytes object 82 Bytes8.1 pulses differenceCRWTU
113Input BI7 - Switching status 2-bytes floating value object 82 Bytes9.1 temperature (°C)CRWTU
114Input BI7 - Scene number1 Byte17.1 scene numberCT
115Input BI8 - Lock command1 Bit1.3 enableCWU
116Input BI8 - Switching status 1-bit object 11 Bit1.1 switchCRWTU
116Input BI8 - Switching status 2-bits object 12 Bit2.1 switch controlCRWTU
116Input BI8 - Switching status 1-unsigned byte object 11 Byte5.1 percentage (0..100%)CRWTU
116Input BI8 - Switching status 1-signed byte object 11 Byte6.1 percentage (-128..127%)CRWTU
116Input BI8 - Switching status 2-unsigned bytes object 12 Bytes7.1 pulsesCRWTU
116Input BI8 - Switching status 2-signed bytes object 12 Bytes8.1 pulses differenceCRWTU
116Input BI8 - Switching status 2-bytes floating value object 12 Bytes9.1 temperature (°C)CRWTU
117Input BI8 - Switching status 1-bit object 21 Bit1.1 switchCRWTU
117Input BI8 - Switching status 2-bits object 22 Bit2.1 switch controlCRWTU
117Input BI8 - Switching status 1-unsigned byte object 21 Byte5.1 percentage (0..100%)CRWTU
117Input BI8 - Switching status 1-signed byte object 21 Byte6.1 percentage (-128..127%)CRWTU
117Input BI8 - Switching status 2-unsigned bytes object 22 Bytes7.1 pulsesCRWTU
117Input BI8 - Switching status 2-signed bytes object 22 Bytes8.1 pulses differenceCRWTU
117Input BI8 - Switching status 2-bytes floating value object 22 Bytes9.1 temperature (°C)CRWTU
118Input BI8 - Switching status 1-bit object 31 Bit1.1 switchCRWTU
118Input BI8 - Switching status 2-bits object 32 Bit2.1 switch controlCRWTU
118Input BI8 - Switching status 1-unsigned byte object 31 Byte5.1 percentage (0..100%)CRWTU
118Input BI8 - Switching status 1-signed byte object 31 Byte6.1 percentage (-128..127%)CRWTU
118Input BI8 - Switching status 2-unsigned bytes object 32 Bytes7.1 pulsesCRWTU
118Input BI8 - Switching status 2-signed bytes object 32 Bytes8.1 pulses differenceCRWTU
118Input BI8 - Switching status 2-bytes floating value object 32 Bytes9.1 temperature (°C)CRWTU
119Input BI8 - Switching status 1-bit object 41 Bit1.1 switchCRWTU
119Input BI8 - Switching status 2-bits object 42 Bit2.1 switch controlCRWTU
119Input BI8 - Switching status 1-unsigned byte object 41 Byte5.1 percentage (0..100%)CRWTU
119Input BI8 - Switching status 1-signed byte object 41 Byte6.1 percentage (-128..127%)CRWTU
119Input BI8 - Switching status 2-unsigned bytes object 42 Bytes7.1 pulsesCRWTU
119Input BI8 - Switching status 2-signed bytes object 42 Bytes8.1 pulses differenceCRWTU
119Input BI8 - Switching status 2-bytes floating value object 42 Bytes9.1 temperature (°C)CRWTU
120Input BI8 - Switching status 1-bit object 51 Bit1.1 switchCRWTU
120Input BI8 - Switching status 2-bits object 52 Bit2.1 switch controlCRWTU
120Input BI8 - Switching status 1-unsigned byte object 51 Byte5.1 percentage (0..100%)CRWTU
120Input BI8 - Switching status 1-signed byte object 51 Byte6.1 percentage (-128..127%)CRWTU
120Input BI8 - Switching status 2-unsigned bytes object 52 Bytes7.1 pulsesCRWTU
120Input BI8 - Switching status 2-signed bytes object 52 Bytes8.1 pulses differenceCRWTU
120Input BI8 - Switching status 2-bytes floating value object 52 Bytes9.1 temperature (°C)CRWTU
121Input BI8 - Switching status 1-bit object 61 Bit1.1 switchCRWTU
121Input BI8 - Switching status 2-bits object 62 Bit2.1 switch controlCRWTU
121Input BI8 - Switching status 1-unsigned byte object 61 Byte5.1 percentage (0..100%)CRWTU
121Input BI8 - Switching status 1-signed byte object 61 Byte6.1 percentage (-128..127%)CRWTU
121Input BI8 - Switching status 2-unsigned bytes object 62 Bytes7.1 pulsesCRWTU
121Input BI8 - Switching status 2-signed bytes object 62 Bytes8.1 pulses differenceCRWTU
121Input BI8 - Switching status 2-bytes floating value object 62 Bytes9.1 temperature (°C)CRWTU
122Input BI8 - Switching status 1-bit object 71 Bit1.1 switchCRWTU
122Input BI8 - Switching status 2-bits object 72 Bit2.1 switch controlCRWTU
122Input BI8 - Switching status 1-unsigned byte object 71 Byte5.1 percentage (0..100%)CRWTU
122Input BI8 - Switching status 1-signed byte object 71 Byte6.1 percentage (-128..127%)CRWTU
122Input BI8 - Switching status 2-unsigned bytes object 72 Bytes7.1 pulsesCRWTU
122Input BI8 - Switching status 2-signed bytes object 72 Bytes8.1 pulses differenceCRWTU
122Input BI8 - Switching status 2-bytes floating value object 72 Bytes9.1 temperature (°C)CRWTU
123Input BI8 - Switching status 1-bit object 81 Bit1.1 switchCRWTU
123Input BI8 - Switching status 2-bits object 82 Bit2.1 switch controlCRWTU
123Input BI8 - Switching status 1-unsigned byte object 81 Byte5.1 percentage (0..100%)CRWTU
123Input BI8 - Switching status 1-signed byte object 81 Byte6.1 percentage (-128..127%)CRWTU
123Input BI8 - Switching status 2-unsigned bytes object 82 Bytes7.1 pulsesCRWTU
123Input BI8 - Switching status 2-signed bytes object 82 Bytes8.1 pulses differenceCRWTU
123Input BI8 - Switching status 2-bytes floating value object 82 Bytes9.1 temperature (°C)CRWTU
124Input BI8 - Scene number1 Byte17.1 scene numberCT
125Input BI9 - Lock command1 Bit1.3 enableCWU
126Input BI9 - Window contact status1 Bit1.1 switchCRT
126Input BI9 - Contact status1 Bit1.1 switchCRT
127Input BI10 - Lock command1 Bit1.3 enableCWU
128Input BI10 - Help request status1 Bit1.1 switchCRT
129Input BI11 - Lock command1 Bit1.3 enableCWU
130Input BI11 - Room cleaning request status1 Bit1.1 switchCWTU
131Room temperature 1 (from bus)2 Bytes9.1 temperature (°C)CWTU
132Room temperature 2 (from bus)2 Bytes9.1 temperature (°C)CWTU
133Outdoor temperature (from bus)2 Bytes9.1 temperature (°C)CWTU
134Coil battery temperature (from bus)2 Bytes9.1 temperature (°C)CWTU
135Antistratification temperature (from bus)2 Bytes9.1 temperature (°C)CWTU
136Flow temperature (from bus)2 Bytes9.1 temperature (°C)CWTU
137Drip tray contact (from bus)1 Bit1.5 alarmCWTU
138Window contact 1 (from bus)1 Bit1.19 window/doorCWTU
139Window contact 2 (from bus)1 Bit1.19 window/doorCWTU
140Presence sensor 1 (from bus)1 Bit1.18 occupancyCWTU
141Presence sensor 2 (from bus)1 Bit1.18 occupancyCWTU
142External badge (from bus)1 Bit1.18 occupancyCWTU
143Internal badge (from bus)1 Bit1.18 occupancyCWTU
144Output BO1 - On/off command1 Bit1.1 switchCW
145Output BO1 - On/off status1 Bit1.1 switchCRT
146Output BO1 - Lock command1 Bit1.3 enableCW
147Output BO1 - Forcing command2 Bit2.1 switch controlCW
148Output BO1 - Scene number1 Byte17.1 scene numberCW
149Output BO2 - On/off command1 Bit1.1 switchCW
150Output BO2 - On/off status1 Bit1.1 switchCRT
151Output BO2 - Lock command1 Bit1.3 enableCW
152Output BO2 - Forcing command2 Bit2.1 switch controlCW
153Output BO2 - Scene number1 Byte17.1 scene numberCW
154Outputs BO1 and BO2 - Move up-down command1 Bit1.8 up/downCW
155Outputs BO1 and BO2 - Stop-step up-down command1 Bit1.7 stepCW
156Outputs BO1 and BO2 - Dedicated stop command1 Bit1.17 triggerCW
157Outputs BO1 and BO2 - Info move1 Bit1.8 up/downCRT
158Outputs BO1 and BO2 - Valid current abs position1 Bit1.2 booleanCRT
159Outputs BO1 and BO2 - Lock command1 Bit1.3 enableCW
160Outputs BO1 and BO2 - Forcing command2 Bit2.8 direction control 1CW
161Outputs BO1 and BO2 - Scene number1 Byte17.1 scene numberCW
162Outputs BO1 and BO2 - Dimmer position command4 Bit3.8 blind controlCW
163Outputs BO1 and BO2 - Abs position command1 Byte5.1 percentage (0..100%)CW
164Outputs BO1 and BO2 - Abs position status1 Byte5.1 percentage (0..100%)CRT
165Outputs BO1 and BO2 - Dimmer slats command4 Bit3.8 blind controlCW
166Outputs BO1 and BO2 - Abs slats position command1 Byte5.1 percentage (0..100%)CW
167Outputs BO1 and BO2 - Abs slats position status1 Byte5.1 percentage (0..100%)CRT
168Output BO3 - On/off command1 Bit1.1 switchCW
169Output BO3 - On/off status1 Bit1.1 switchCRT
170Output BO3 - Lock command1 Bit1.3 enableCW
171Output BO3 - Forcing command2 Bit2.1 switch controlCW
172Output BO3 - Scene number1 Byte17.1 scene numberCW
173Output BO4 - On/off command1 Bit1.1 switchCW
174Output BO4 - On/off status1 Bit1.1 switchCRT
175Output BO4 - Lock command1 Bit1.3 enableCW
176Output BO4 - Forcing command2 Bit2.1 switch controlCW
177Output BO4 - Scene number1 Byte17.1 scene numberCW
178Outputs BO3 and BO4 - Move up-down command1 Bit1.8 up/downCW
179Outputs BO3 and BO4 - Stop-step up-down command1 Bit1.7 stepCW
180Outputs BO3 and BO4 - Dedicated stop command1 Bit1.17 triggerCW
181Outputs BO3 and BO4 - Info move1 Bit1.8 up/downCRT
182Outputs BO3 and BO4 - Valid current abs position1 Bit1.2 booleanCRT
183Outputs BO3 and BO4 - Lock command1 Bit1.3 enableCW
184Outputs BO3 and BO4 - Forcing command2 Bit2.8 direction control 1CW
185Outputs BO3 and BO4 - Scene number1 Byte17.1 scene numberCW
186Outputs BO3 and BO4 - Dimmer position command4 Bit3.8 blind controlCW
187Outputs BO3 and BO4 - Abs position command1 Byte5.1 percentage (0..100%)CW
188Outputs BO3 and BO4 - Abs position status1 Byte5.1 percentage (0..100%)CRT
189Outputs BO3 and BO4 - Dimmer slats command4 Bit3.8 blind controlCW
190Outputs BO3 and BO4 - Abs slats position command1 Byte5.1 percentage (0..100%)CW
191Outputs BO3 and BO4 - Abs slats position status1 Byte5.1 percentage (0..100%)CRT
192Output BO5 - On/off command1 Bit1.1 switchCW
193Output BO5 - On/off status1 Bit1.1 switchCRT
194Output BO5 - Lock command1 Bit1.3 enableCW
195Output BO5 - Forcing command2 Bit2.1 switch controlCW
196Output BO5 - Scene number1 Byte17.1 scene numberCW
197Output BO6 - On/off command1 Bit1.1 switchCW
198Output BO6 - On/off status1 Bit1.1 switchCRT
199Output BO6 - Lock command1 Bit1.3 enableCW
200Output BO6 - Forcing command2 Bit2.1 switch controlCW
201Output BO6 - Scene number1 Byte17.1 scene numberCW
202Output BO7 - On/off command1 Bit1.1 switchCW
203Output BO7 - On/off status1 Bit1.1 switchCRT
204Output BO7 - Lock command1 Bit1.3 enableCW
205Output BO7 - Forcing command2 Bit2.1 switch controlCW
206Output BO7 - Scene number1 Byte17.1 scene numberCW
207Output BO8 - On/off command1 Bit1.1 switchCW
208Output BO8 - On/off status1 Bit1.1 switchCRT
209Output BO8 - Lock command1 Bit1.3 enableCW
210Output BO8 - Forcing command2 Bit2.1 switch controlCW
211Output BO8 - Scene number1 Byte17.1 scene numberCW
212Output BO9 - On/off command1 Bit1.1 switchCW
213Output BO9 - On/off status1 Bit1.1 switchCRT
214Output BO9 - Lock command1 Bit1.3 enableCW
215Output BO9 - Forcing command2 Bit2.1 switch controlCW
216Output BO9 - Scene number1 Byte17.1 scene numberCW
217Output BO10 - On/off command1 Bit1.1 switchCW
218Output BO10 - On/off status1 Bit1.1 switchCRT
219Output BO10 - Lock command1 Bit1.3 enableCW
220Output BO10 - Forcing command2 Bit2.1 switch controlCW
221Output BO10 - Scene number1 Byte17.1 scene numberCW
222Door lock - Pulse command1 Bit1.1 switchCW
223Door lock - Pulse status1 Bit1.1 switchCRT
224Room temperature controller status1 Bit1.3 enableCRT
225Disable room temperature controller1 Bit1.1 switchCW
226Fan continuous speed command1 Byte5.1 percentage (0..100%)CW
226First fan speed command1 Bit1.1 switchCW
226Fan continuous speed command counter1 Byte5.10 counter pulses (0..255)CW
226Fan continuous speed manual command1 Byte5.1 percentage (0..100%)CW
227Second fan speed command1 Bit1.1 switchCW
227Fan continuous speed manual counter1 Byte5.10 counter pulses (0..255)CW
228Third fan speed command1 Bit1.1 switchCW
229Heating valve command (on/off)1 Bit1.1 switchCW
229Heating valve command (PWM)1 Byte5.1 percentage (0..100%)CW
229Heating/cooling valve command (on/off)1 Bit1.1 switchCW
229Heating/cooling valve command (PWM)1 Byte5.1 percentage (0..100%)CW
230Cooling valve command (on/off)1 Bit1.1 switchCW
230Cooling valve command (PWM)1 Byte5.1 percentage (0..100%)CW
231Heating/cooling changeover command1 Bit1.100 heating/coolingCW
232Actual fan speed %1 Byte5.1 percentage (0..100%)CRT
233Fan stopped status1 Bit1.1 switchCRT
234First fan speed status1 Bit1.1 switchCRT
235Second fan speed status1 Bit1.1 switchCRT
236Third fan speed status1 Bit1.1 switchCRT
237Counter speed fan status1 Byte5.10 counter pulses (0..255)CRT
238Heating/cooling valve status1 Bit1.1 switchCRT
238Heating valve status1 Bit1.1 switchCRT
239Cooling valve status1 Bit1.1 switchCRT
240Heating/cooling status out1 Bit1.100 heating/coolingCRT
241Heating/cooling changeover command1 Bit1.100 heating/coolingCW
242HVAC mode IN1 Byte20.102 HVAC modeCW
243HVAC manual mode1 Byte20.102 HVAC modeCW
244HVAC chrono mode active status1 Bit1.11 stateCRWTU
245HVAC mode OUT1 Byte20.102 HVAC modeCRT
246Actual setpoint2 Bytes9.1 temperature (°C)CRT
247Input setpoint2 Bytes9.1 temperature (°C)CW
248Comfort setpoint (heating)2 Bytes9.1 temperature (°C)CRWTU
249Comfort setpoint (cooling)2 Bytes9.1 temperature (°C)CRWTU
250Standby offset (heating)2 Bytes9.2 temperature difference (K)CRWTU
250Standby setpoint (heating)2 Bytes9.1 temperature (°C)CRWTU
251Standby offset (cooling)2 Bytes9.2 temperature difference (K)CRWTU
251Standby setpoint (cooling)2 Bytes9.1 temperature (°C)CRWTU
252Economy offset (heating)2 Bytes9.2 temperature difference (K)CRWTU
252Economy setpoint (heating)2 Bytes9.1 temperature (°C)CRWTU
253Economy offset (cooling)2 Bytes9.2 temperature difference (K)CRWTU
253Economy setpoint (cooling)2 Bytes9.1 temperature (°C)CRWTU
254Building protection (heating)2 Bytes9.1 temperature (°C)CRWTU
255Building protection (cooling)2 Bytes9.1 temperature (°C)CRWTU
256Manual/forced setpoint active status1 Bit1.11 stateCRWTU
257Manual setpoint2 Bytes9.1 temperature (°C)CRWTU
258Cooling compensation offset2 Bytes9.2 temperature difference (K)CRT
259Temperature controller output1 Byte5.1 percentage (0..100%)CRT
260Fan working time (hours)2 Bytes7.7 time (h)CRT
261Fan working time (seconds)4 Bytes13.100 time lag (s)CRT
262Fan disable from bus1 Bit1.3 enableCW
263Fan manual/auto status1 Bit1.11 stateCRWTU
264Heating/cooling valve disable from bus1 Bit1.3 enableCW
264Heating valve disable from bus1 Bit1.3 enableCW
265Cooling valve disable from bus1 Bit1.3 enableCW
266Controller output forced from bus1 Byte5.1 percentage (0..100%)CW
267Controller output automatic/forced from bus1 Bit1.3 enableCW
268Output V1 from bus1 Bit1.1 switchCW
269Output V2 from bus1 Bit1.1 switchCW
270Output V3 from bus1 Bit1.1 switchCW
271Output heating valve from bus1 Bit1.1 switchCW
272Output cooling valve from bus1 Bit1.1 switchCW
273Output 0-10V from bus1 Byte5.1 percentage (0..100%)CW
274Fan speed limit enable1 Bit1.3 enableCW
275Weighted room temperature2 Bytes9.1 temperature (°C)CRT
276Logic function 1 - Input 11 Bit1.1 switchCWTU
277Logic function 1 - Input 21 Bit1.1 switchCWTU
278Logic function 1 - Input 31 Bit1.1 switchCWTU
279Logic function 1 - Input 41 Bit1.1 switchCWTU
280Logic function 1 - Output1 Bit1.1 switchCRT
281Logic function 2 - Input 11 Bit1.1 switchCWTU
282Logic function 2 - Input 21 Bit1.1 switchCWTU
283Logic function 2 - Input 31 Bit1.1 switchCWTU
284Logic function 2 - Input 41 Bit1.1 switchCWTU
285Logic function 2 - Output1 Bit1.1 switchCRT
286Logic function 3 - Input 11 Bit1.1 switchCWTU
287Logic function 3 - Input 21 Bit1.1 switchCWTU
288Logic function 3 - Input 31 Bit1.1 switchCWTU
289Logic function 3 - Input 41 Bit1.1 switchCWTU
290Logic function 3 - Output1 Bit1.1 switchCRT
291Logic function 4 - Input 11 Bit1.1 switchCWTU
292Logic function 4 - Input 21 Bit1.1 switchCWTU
293Logic function 4 - Input 31 Bit1.1 switchCWTU
294Logic function 4 - Input 41 Bit1.1 switchCWTU
295Logic function 4 - Output1 Bit1.1 switchCRT
Parameters (307)
ParameterTypeDefault
Inputs BI1 and BI2listindependent or single
Inputs BI3 and BI4listindependent or single
Delay after bus voltage recoverytime400
Input AI1/BI1listenabled DI
Long press timetime80
Lock functionlistdisabled
Invert lock device signallistnot inverted
Lock after bus recoverylistno
Typelistsend values or sequences
Number of Communication ObjectsunsignedInt 1…81
Eventlistactivation / release
Behavior at lockinglistnone
Behavior at unlockinglistnone
Send cyclicallylistnone
Cyclic sending intervaltime120
Send delaytime0
Communication object dimensionlist1 bit value
Reaction to activationlisttoggle
Reaction to releaselistoff
Reaction to short presslisttoggle
Reaction to long presslistoff
Reaction to activationlistenable on / down
Reaction to releaselistdisable
Reaction to short presslistenable on / down
Reaction to long presslistdisable
Reaction to activationlistsend value 1
Reaction to releaselistnone
Reaction to short presslistsend value 1
Reaction to long presslistnone
Value 1unsignedInt 0…2550
Value 2unsignedInt 0…2550
Value 1signedInt -128…1270
Value 2signedInt -128…1270
Value 1unsignedInt 0…655350
Value 2unsignedInt 0…655350
Value 1signedInt -32768…327670
Value 2signedInt -32768…327670
Value 1float -671088.64…670760.960
Value 2float -671088.64…670760.960
Reaction to activationliston
Reaction to short pressliston
Toggle modelistenabled
Short / long actionlistoff / darker
Up / down actionlistup
Venetian blind modelistdisabled
Learning modelistdisabled
Scene activationlistsend first scene only
First scene numberunsignedInt 1…641
Second scene numberunsignedInt 1…642
Input AI2/BI2listenabled DI
Typelistdimming
UselistBI1 increases, BI2 decreases
UselistBI1 up, BI2 down
UselistBI1 on, BI2 off
Input BI3listenabled
Input BI4listenabled
UselistBI3 on, BI4 off
UselistBI3 increases, BI4 decreases
UselistBI3 up, BI4 down
Reaction to long presslistdarker
Value 1unsignedInt 0…1000
Value 2unsignedInt 0…1000
Logic functionlistdisabled
Logic operationlistOR
Output cyclic transmission intervallistno sending
Logic object 1listdisabled
Logic object 2listdisabled
Logic object 3listdisabled
Logic object 4listdisabled
Logic object 1 negatedlistno
Logic object 2 negatedlistno
Logic object 3 negatedlistno
Logic object 4 negatedlistno
Logic object 1 read at startuplistno
Logic object 2 read at startuplistno
Logic object 3 read at startuplistno
Logic object 4 read at startuplistno
Logic object 1 default valuelistnone
Logic object 2 default valuelistnone
Logic object 3 default valuelistnone
Logic object 4 default valuelistnone
Output sendlistboth values
Output updatingliston value change
Technical alarmlistdisabled
Debounce timetime5
Contact typelistNO (normally open)
Cyclic sending intervallistno sending
Threshold 1listnot active
Threshold 2listnot active
Value [°C]float 0…507
Value [°C]float 0…5045
Hysteresislist0.4 K
Temperature offsetlist0.0 °C
Minimum change of value to send [K]float 0…50.5
Filter typelistmedium
Inputs BI5 and BI6listindependent or single
Manual operationslistenabled
Restore auto mode timetime900
Outputs BO3 and BO4list2 binary outputs
Outputs BO1 and BO2listvenetian blind / shutter
Device power off alarmlistdisabled
Disable from buslistno
Behavior at bus onlistnone
Behavior at device power onlistnone
Behavior after downloadlistnone
Bus on positionunsignedInt 0…1000
Bus on slats positionunsignedInt 0…1000
Device power on positionunsignedInt 0…1000
Device power on slats positionunsignedInt 0…1000
After download positionunsignedInt 0…1000
After download slats positionunsignedInt 0…1000
Locking functionlistdisabled
Lock device signallistnot inverted
After bus recoverylistprevious state
Lock start positionunsignedInt 0…1000
Lock start slats positionunsignedInt 0…1000
Lock end positionunsignedInt 0…1000
Lock end slat positionunsignedInt 0…1000
Forcing functionlistdisabled
Behavior end forced controllistnone
Behavior after bus recoverylistnot forced
End forced positionunsignedInt 0…1000
End forced slat positionunsignedInt 0…1000
Bus recovery forced positionunsignedInt 0…1000
Bus recovery forced slat positionunsignedInt 0…1000
Scenes functionlistdisabled
Download overwrites learned behaviorlistyes
Output behaviorlistfully opened
Scene 1listdisabled
Scene 2listdisabled
Scene 3listdisabled
Scene 4listdisabled
Scene 5listdisabled
Scene 6listdisabled
Scene 7listdisabled
Scene 8listdisabled
Scene numberunsignedInt 1…641
Scene positionunsignedInt 0…1000
Scene slats positionunsignedInt 0…1000
Activation delaytime0
Uselistshutter
Position control with dimmerlistno
Slats control with dimmerlistno
Reversion pause timetime300
Move up timetime15
Move down timetime15
Slat movement timetime15
Slat step timetime100
Output BO3listenabled
Rele operationlistnot inverted
Behavior at device power onlistno change
Behavior at bus onlistprevious state
Behavior after downloadlistno change
Status feedback telegramlistenabled
Delay after bus voltage recoverytime300
Transmission cycle timetime0
On delay timetime0
Off delay timetime0
Behavior end forced controllistno change
Behavior after bus recoverylistprevious state
Behavior at lockinglistoff
Behavior at unlockinglistvalue before locking
Output behaviorliston
Output BO4listenabled
Behavior at unlockinglistoff
Output BO5listenabled
Output BO6listenabled
Output BO7listenabled
Output BO8listenabled
Digital sensors timeouttime300
Room temperature 1listdisabled
Antistratification temperaturelistdisabled
Outdoor temperaturelistdisabled
Coil temperaturelistdisabled
Flow temperaturelistdisabled
Window contact 1listdisabled
Window contact 2listdisabled
Presence sensor 1listdisabled
Presence sensor 2listdisabled
Signallistnot inverted
Applicationlistfan-coil
Functionlistheating
Distribution typelist2 pipes
Controllerlistinternal
Report filter changelistno
Ventilation Object formatlistpercentage [DPT 5.001]
Analog sensors timeouttime300
Drip tray levellistdisabled
First speed threshold [%]unsignedInt 0…10010
Control typelist1 speed (relais)
Cold startlistno
Warm startlistno
Second speed threshold [%]unsignedInt 0…10040
Third speed threshold [%]unsignedInt 0…10070
Hysteresis [%]unsignedInt 0…305
Heat exchange coil temperatureunsignedInt 28…4035
Heat exchange coil temperatureunsignedInt 7…1812
Speed control low limit [%]unsignedInt 0…1000
Speed control high limit [%]unsignedInt 0…100100
2-sensor antistratificationlistdisabled
Disable from buslistdisabled
Temperature differentiallist2.00 K/m
Hysteresislist0.6 K
Start delaylist0 s
Stop delaylist0 s
Control feedbacklistno
Control typeliston/off
Control can be disabled from buslistno
Valve position feedbacklistdisabled
Valve position after timeoutlistoff
PWM cycle timetime15
Min. control value [%]unsignedInt 0…3015
Max. control value [%]unsignedInt 70…10085
Antiscuff protectionlistdisabled
Frequencylistonce a week
Time intervallist10 s
Setpoint typelistrelative
Heating/cooling changeoverlistfrom bus
Temperature for changeover (heating)float 20…5035
Temperature for changeover (cooling)float 5…2016
Changeover cyclic sending intervallistno sending
Comfort setpoint [°C]float 10…5021
Standby offset [0.1 K]signedInt -50…-10-30
Economy offset [0.1 K]signedInt -80…-10-50
Building protection [°C]float 2…107
Proportional band [0.1 K]unsignedInt 0…25530
Integral time [min]unsignedInt 0…2550
Min change of value to send [%]unsignedInt 0…10010
Forced modelistno
Comfort setpoint [°C]float 10…5023
Standby offset [0.1 K]signedInt 10…5030
Economy offset [0.1 K]signedInt 10…8050
Building protection [°C]float 20…5036
Neutral zone [0.1 K]signedInt 10…5020
Summer compensationlistdisabled
Lowest external temperature [°C]unsignedInt 25…4025
Coefficientlist1 K each 4 K external temp. change
Min change to send valuelist0.6 K
Window contacts functionlistdisabled
Time to wait before HVAC changetime60
Presence sensors functionlistdisabled
Uselistcomfort extension
Modeslistcomfort - standby
In case of driplistclose valve and switch fan off
Drip controllistdisabled
Change filter warning after [weeks]unsignedInt 1…12816
Send warningliston filter change only
Send usage timelistno sending (only reading)
Cyclic sending intervallist24 h
Speed at timeoutlistspeed 1
Speed at timeoutlist20%
Output value at the first speedunsignedInt 0…10010
Output value at the second speedunsignedInt 0…10040
Output value at the third speedunsignedInt 0…10070
Communication Objectlistseparated
Valve Object formatlistoutput status [DPT 1.001]
First speed threshold [0.1K]unsignedInt 0…2550
Second speed threshold [0.1K]unsignedInt 0…25510
Third speed threshold [0.1K]unsignedInt 0…25520
Hysteresis [0.1K]list0.3 K
Temperature setpoint [°C]float 10…5021
Temperature setpoint [°C]float 10…5023
Fan speed limit from buslistnot limited
Setpoint CO typelistabsolute
Communication Object typelistseconds [DPT 13.100]
Speed output low limit [%]unsignedInt 0…1000
Speed output high limit [%]unsignedInt 0…100100
Minimum change of value to send [%]unsignedInt 0…305
RoomTemplistno
End of manual operationlistat first telegram from bus
Time-scheduled antistratificationlistdisabled
Frequencylist30 min
Time intervallist2 min
Fan controllistdepending on temperature
Room temperature 2listdisabled
External badgelistdisabled
Internal badgelistdisabled
Temperature threshold 1 enable from buslistdisabled
Temperature threshold 2 enable from buslistdisabled
External controller timeouttime0
Cyclic reading intervallistno reading
Read on initlistdisabled
Typelist[AI] room temperature sensor
Input BI5listenabled
Input BI6listenabled
UselistBI5 on, BI6 off
UselistBI5 increases, BI6 decreases
UselistBI5 up, BI6 down
Input BI7listenabled
Input BI8listenabled
Output BO9listenabled
Output BO10listenabled
Input BI9listwindow contact
Input BI10listenabled
Input BI11listenabled
Electric locklistenabled
Pulse lengthtime100
Weight temperature AI1unsignedInt 1…101
Weight temperature AI2unsignedInt 1…101
Weight room temperature from bus 1unsignedInt 1…101
Weight room temperature from bus 2unsignedInt 1…101
WeightedTemplistdisabled
Output BO1listenabled
Output BO2listenabled
HU1listyes
Disable temperature controller from buslistno
Signal from buslistnot inverted

Version history

ApplicationApp noFingerprintFirst seenSizeFile
APEKHU1TP 0.1 latest$4855C2A32026-11-25359 KBDownload
APEKHU1TP 0.1$4855C2A32026-11-25359 KBDownload
APEKHU1TP 0.1$4855C2A32026-11-25359 KBDownload

About this file

This is the official ETS product database for the Ekinex S.p.A. Office Controller (EK-HU1-TP), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Ekinex S.p.A.

All Ekinex S.p.A. products