Ekinex S.p.A. EK-HE1-TP Actuator-controller 8 channels for electrothermal valve drives

Actuator-controller 8 channels for electrothermal valve drives EK-HE1-TP

Ekinex S.p.A. · Order number EK-HE1-TP · Heating, cooling and ventilation

Actuator-controller 8 channels for electrothermal valve drives

Download .knxprod APEKHE1TP 0.1 · 175 KB

Product

ManufacturerEkinex S.p.A.
Product nameActuator-controller 8 channels for electrothermal valve drives
Order numberEK-HE1-TP
HardwareActuator-controller 8 channels for electrothermal valve drives
MediumTwisted Pair
Bus current (mA)35
Rail mountedNo
RegistrationRegistered · 2016-12-02
Languagesen-US, de-DE, fr-FR, it-IT
Catalog entryM-00B6_H-000032-1_HP-4845-01-CAC3_CI-EK.2DHE1.2DTP-1
FingerprintCAC3
SHA-2566474f646fbefc99b18d0c3645940ca499d899eebeaae534c3703bb20b1dccce4
First seen2026-11-25
Markets69 markets

Application program: APEKHE1TP 0.1

Application number$4845
Version0.1
Mask versionMV-0705 (7.5)
KNX Data SecureNo
Minimum ETS version4.0
Parameters734
Group objects470
Group objects (470)
NoNameFunctionSizeDPTFlags
0Heating/cooling changeover command (2 pipes)1 Bit1.100 heating/coolingCWTU
1Heating/cooling changeover status (2 pipes)1 Bit1.100 heating/coolingCRT
2Heating/cooling changeover command (4 pipes) - channel 11 Bit1.100 heating/coolingCWTU
3Heating/cooling changeover status (4 pipes) - channel 11 Bit1.100 heating/coolingCRT
4Heating/cooling changeover command (4 pipes) - channel 21 Bit1.100 heating/coolingCWTU
5Heating/cooling changeover status (4 pipes) - channel 21 Bit1.100 heating/coolingCRT
6Heating/cooling changeover command (4 pipes) - channel 31 Bit1.100 heating/coolingCWTU
7Heating/cooling changeover status (4 pipes) - channel 31 Bit1.100 heating/coolingCRT
8Heating/cooling changeover command (4 pipes) - channel 41 Bit1.100 heating/coolingCWTU
9Heating/cooling changeover status (4 pipes) - channel 41 Bit1.100 heating/coolingCRT
10Enable general forced mode from bus1 Bit1.3 enableCW
13Test mode activated1 Bit1.3 enableCRT
14Energy request (heating)1 Bit1.1 switchCRT
15Energy request (cooling)1 Bit1.1 switchCRT
16Technical alarm1 Bit1.5 alarmCRT
17Communication alarm1 Bit1.5 alarmCRT
18Thermal generator lock alarm1 Bit1.5 alarmCW
19Short circuit alarm1 Bit1.5 alarmCRT
20Power off alarm output 1A, 1B, 2A and 2B1 Bit1.5 alarmCRT
21Power off alarm output 3A, 3B, 4A and 4B1 Bit1.5 alarmCRT
22Alarm text14 Bytes16.0 Character String (ASCII)CRT
23Disable front keyboard1 Bit1.3 enableCW
24Valve on/off command - channel 1A1 Bit1.1 switchCWTU
24Valve on/off status - channel 1A1 Bit1.1 switchCRT
24Valve on/off heating command - channel 1A1 Bit1.1 switchCWTU
24Valve continuous heating command - channel 1A1 Byte5.1 percentage (0..100%)CWTU
24Valve continuous command - channel 1A1 Byte5.1 percentage (0..100%)CWTU
24Valve continuous status - channel 1A1 Byte5.1 percentage (0..100%)CRT
24Valve continuous heating status - channel 1A1 Byte5.1 percentage (0..100%)CRT
24Valve on/off heating status - channel 1A1 Bit1.1 switchCRT
24On/off output command - channel 1A1 Bit1.1 switchCW
25Valve disable from bus - channel 1A1 Bit1.3 enableCW
25Heating valve disable from bus - channel 1A1 Bit1.3 enableCW
26Enable forced mode from bus - channel 1A1 Bit1.3 enableCW
26Enable heating forced mode from bus - channel 1A1 Bit1.3 enableCW
27Temperature control alarm - channel 1A1 Bit1.5 alarmCRT
27Temperature control alarm - channel 11 Bit1.5 alarmCRT
28Room temperature 1 (from bus) - channel 1A2 Bytes9.1 temperature (°C)CWT
28Room temperature 1 (from bus) - channel 12 Bytes9.1 temperature (°C)CWT
29Room temperature 2 (from bus) - channel 1A2 Bytes9.1 temperature (°C)CWT
29Room temperature 2 (from bus) - channel 12 Bytes9.1 temperature (°C)CWT
30Floor surface temperature (from bus) - channel 1A2 Bytes9.1 temperature (°C)CWT
30Floor surface temperature (from bus) - channel 12 Bytes9.1 temperature (°C)CWT
31Anticondensation sensor (from bus) - channel 1A1 Bit1.1 switchCWT
31Anticondensation sensor (from bus) - channel 11 Bit1.1 switchCWT
32Windows contact sensor (from bus) - channel 1A1 Bit1.19 window/doorCWT
32Windows contact sensor (from bus) - channel 11 Bit1.19 window/doorCWT
33Presence sensor (from bus) - channel 1A1 Bit1.18 occupancyCWT
33Presence sensor (from bus) - channel 11 Bit1.18 occupancyCWT
34HVAC mode in - channel 1A1 Byte20.102 HVAC modeCW
34HVAC mode in - channel 11 Byte20.102 HVAC modeCW
35HVAC manual mode - channel 1A1 Byte20.102 HVAC modeCW
35HVAC manual mode - channel 11 Byte20.102 HVAC modeCW
36Chrono active status - channel 1A1 Bit1.11 stateCRWTU
36Chrono active status - channel 11 Bit1.11 stateCRWTU
37HVAC mode out - channel 1A1 Byte20.102 HVAC modeCRT
37HVAC mode out - channel 11 Byte20.102 HVAC modeCRT
38Actual setpoint - channel 1A2 Bytes9.1 temperature (°C)CRT
38Actual setpoint - channel 12 Bytes9.1 temperature (°C)CRT
39Manual setpoint - channel 1A2 Bytes9.1 temperature (°C)CW
39Manual setpoint - channel 12 Bytes9.1 temperature (°C)CW
40Manual setpoint active status - channel 1A1 Bit1.11 stateCRWTU
40Manual setpoint active status - channel 11 Bit1.11 stateCRWTU
41Comfort setpoint (heating) - channel 1A2 Bytes9.1 temperature (°C)CRWTU
41Input setpoint - channel 1A2 Bytes9.1 temperature (°C)CRWTU
41Input setpoint - channel 12 Bytes9.1 temperature (°C)CRWTU
41Comfort setpoint (heating) - channel 12 Bytes9.1 temperature (°C)CRWTU
42Comfort setpoint (cooling) - channel 1A2 Bytes9.1 temperature (°C)CRWTU
42Comfort setpoint (cooling) - channel 12 Bytes9.1 temperature (°C)CRWTU
43Standby setpoint (heating) - channel 1A2 Bytes9.1 temperature (°C)CRWTU
43Standby offset (heating) - channel 1A2 Bytes9.2 temperature difference (K)CRWTU
43Standby setpoint (heating) - channel 12 Bytes9.1 temperature (°C)CRWTU
43Standby offset (heating) - channel 12 Bytes9.2 temperature difference (K)CRWTU
44Standby setpoint (cooling) - channel 1A2 Bytes9.1 temperature (°C)CRWTU
44Standby offset (cooling) - channel 1A2 Bytes9.2 temperature difference (K)CRWTU
44Standby offset (cooling) - channel 12 Bytes9.2 temperature difference (K)CRWTU
44Standby setpoint (cooling) - channel 12 Bytes9.1 temperature (°C)CRWTU
45Economy setpoint (heating) - channel 1A2 Bytes9.1 temperature (°C)CRWTU
45Economy offset (heating) - channel 1A2 Bytes9.2 temperature difference (K)CRWTU
45Economy setpoint (heating) - channel 12 Bytes9.1 temperature (°C)CRWTU
45Economy offset (heating) - channel 12 Bytes9.2 temperature difference (K)CRWTU
46Economy setpoint (cooling) - channel 1A2 Bytes9.1 temperature (°C)CRWTU
46Economy offset (cooling) - channel 1A2 Bytes9.2 temperature difference (K)CRWTU
46Economy offset (cooling) - channel 12 Bytes9.2 temperature difference (K)CRWTU
46Economy setpoint (cooling) - channel 12 Bytes9.1 temperature (°C)CRWTU
47Building protection setpoint (heating) - channel 1A2 Bytes9.1 temperature (°C)CRWTU
47Building protection setpoint (heating) - channel 12 Bytes9.1 temperature (°C)CRWTU
48Building protection setpoint (cooling) - channel 1A2 Bytes9.1 temperature (°C)CRWTU
48Building protection setpoint (cooling) - channel 12 Bytes9.1 temperature (°C)CRWTU
49Valve on/off command - channel 1B1 Bit1.1 switchCWTU
49Valve continuous command - channel 1B1 Byte5.1 percentage (0..100%)CWTU
49Valve on/off cooling command - channel 1B1 Bit1.1 switchCWTU
49Valve continuous cooling command - channel 1B1 Byte5.1 percentage (0..100%)CWTU
49Valve on/off status - channel 1B1 Bit1.1 switchCRT
49Valve continuous status - channel 1B1 Byte5.1 percentage (0..100%)CRT
49Valve on/off cooling status - channel 1B1 Bit1.1 switchCRT
49Valve continuous cooling status - channel 1B1 Byte5.1 percentage (0..100%)CRT
49On/off output command - channel 1B1 Bit1.1 switchCW
50Valve disable from bus - channel 1B1 Bit1.3 enableCW
50Cooling valve disable from bus - channel 1B1 Bit1.3 enableCW
51Enable forced mode from bus - channel 1B1 Bit1.3 enableCW
51Enable cooling forced mode from bus - channel 1B1 Bit1.3 enableCW
52Temperature control alarm - channel 1B1 Bit1.5 alarmCRT
53Room temperature 1 (from bus) - channel 1B2 Bytes9.1 temperature (°C)CWT
54Room temperature 2 (from bus) - channel 1B2 Bytes9.1 temperature (°C)CWT
55Floor surface temperature (from bus) - channel 1B2 Bytes9.1 temperature (°C)CWT
56Anticondensation sensor (from bus) - channel 1B1 Bit1.1 switchCWT
57Windows contact sensor (from bus) - channel 1B1 Bit1.19 window/doorCWT
58Presence sensor (from bus) - channel 1B1 Bit1.18 occupancyCWT
59HVAC mode in - channel 1B1 Byte20.102 HVAC modeCW
60HVAC manual mode - channel 1B1 Byte20.102 HVAC modeCW
61Chrono active status - channel 1B1 Bit1.11 stateCRWTU
62HVAC mode out - channel 1B1 Byte20.102 HVAC modeCRT
63Actual setpoint - channel 1B2 Bytes9.1 temperature (°C)CRT
64Manual setpoint - channel 1B2 Bytes9.1 temperature (°C)CW
65Manual setpoint active status - channel 1B1 Bit1.11 stateCRWTU
66Input setpoint - channel 1B2 Bytes9.1 temperature (°C)CRWTU
66Comfort setpoint (heating) - channel 1B2 Bytes9.1 temperature (°C)CRWTU
67Comfort setpoint (cooling) - channel 1B2 Bytes9.1 temperature (°C)CRWTU
68Standby setpoint (heating) - channel 1B2 Bytes9.1 temperature (°C)CRWTU
68Standby offset (heating) - channel 1B2 Bytes9.2 temperature difference (K)CRWTU
69Standby setpoint (cooling) - channel 1B2 Bytes9.1 temperature (°C)CRWTU
69Standby offset (cooling) - channel 1B2 Bytes9.2 temperature difference (K)CRWTU
70Economy setpoint (heating) - channel 1B2 Bytes9.1 temperature (°C)CRWTU
70Economy offset (heating) - channel 1B2 Bytes9.2 temperature difference (K)CRWTU
71Economy setpoint (cooling) - channel 1B2 Bytes9.1 temperature (°C)CRWTU
71Economy offset (cooling) - channel 1B2 Bytes9.2 temperature difference (K)CRWTU
72Building protection setpoint (heating) - channel 1B2 Bytes9.1 temperature (°C)CRWTU
73Building protection setpoint (cooling) - channel 1B2 Bytes9.1 temperature (°C)CRWTU
74Valve on/off command - channel 2A1 Bit1.1 switchCWTU
74Valve continuous command - channel 2A1 Byte5.1 percentage (0..100%)CWTU
74Valve on/off status - channel 2A1 Bit1.1 switchCRT
74Valve continuous status - channel 2A1 Byte5.1 percentage (0..100%)CRT
74On/off output command - channel 2A1 Bit1.1 switchCW
74Valve on/off heating command - channel 2A1 Bit1.1 switchCWTU
74Valve continuous heating command - channel 2A1 Byte5.1 percentage (0..100%)CWTU
74Valve on/off heating status - channel 2A1 Bit1.1 switchCRT
74Valve continuous heating status - channel 2A1 Byte5.1 percentage (0..100%)CRT
75Valve disable from bus - channel 2A1 Bit1.3 enableCW
75Heating valve disable from bus - channel 2A1 Bit1.3 enableCW
76Enable forced mode from bus - channel 2A1 Bit1.3 enableCW
76Enable heating forced mode from bus - channel 2A1 Bit1.3 enableCW
77Temperature control alarm - channel 2A1 Bit1.5 alarmCRT
77Temperature control alarm - channel 21 Bit1.5 alarmCRT
78Room temperature 1 (from bus) - channel 2A2 Bytes9.1 temperature (°C)CWT
78Room temperature 1 (from bus) - channel 22 Bytes9.1 temperature (°C)CWT
79Room temperature 2 (from bus) - channel 2A2 Bytes9.1 temperature (°C)CWT
79Room temperature 2 (from bus) - channel 22 Bytes9.1 temperature (°C)CWT
80Floor surface temperature (from bus) - channel 2A2 Bytes9.1 temperature (°C)CWT
80Floor surface temperature (from bus) - channel 22 Bytes9.1 temperature (°C)CWT
81Anticondensation sensor (from bus) - channel 2A1 Bit1.1 switchCWT
81Anticondensation sensor (from bus) - channel 21 Bit1.1 switchCWT
82Windows contact sensor (from bus) - channel 2A1 Bit1.19 window/doorCWT
82Windows contact sensor (from bus) - channel 21 Bit1.19 window/doorCWT
83Presence sensor (from bus) - channel 2A1 Bit1.18 occupancyCWT
83Presence sensor (from bus) - channel 21 Bit1.18 occupancyCWT
84HVAC mode in - channel 2A1 Byte20.102 HVAC modeCW
84HVAC mode in - channel 21 Byte20.102 HVAC modeCW
85HVAC manual mode - channel 2A1 Byte20.102 HVAC modeCW
85HVAC manual mode - channel 21 Byte20.102 HVAC modeCW
86Chrono active status - channel 2A1 Bit1.11 stateCRWTU
86Chrono active status - channel 21 Bit1.11 stateCRWTU
87HVAC mode out - channel 2A1 Byte20.102 HVAC modeCRT
87HVAC mode out - channel 21 Byte20.102 HVAC modeCRT
88Actual setpoint - channel 2A2 Bytes9.1 temperature (°C)CRT
88Actual setpoint - channel 22 Bytes9.1 temperature (°C)CRT
89Manual setpoint - channel 2A2 Bytes9.1 temperature (°C)CW
89Manual setpoint - channel 22 Bytes9.1 temperature (°C)CW
90Manual setpoint active status - channel 2A1 Bit1.11 stateCRWTU
90Manual setpoint active status - channel 21 Bit1.11 stateCRWTU
91Comfort setpoint (heating) - channel 2A2 Bytes9.1 temperature (°C)CRWTU
91Input setpoint - channel 2A2 Bytes9.1 temperature (°C)CRWTU
91Comfort setpoint (heating) - channel 22 Bytes9.1 temperature (°C)CRWTU
91Input setpoint - channel 22 Bytes9.1 temperature (°C)CRWTU
92Comfort setpoint (cooling) - channel 2A2 Bytes9.1 temperature (°C)CRWTU
92Comfort setpoint (cooling) - channel 22 Bytes9.1 temperature (°C)CRWTU
93Standby setpoint (heating) - channel 2A2 Bytes9.1 temperature (°C)CRWTU
93Standby offset (heating) - channel 2A2 Bytes9.2 temperature difference (K)CRWTU
93Standby setpoint (heating) - channel 22 Bytes9.1 temperature (°C)CRWTU
93Standby offset (heating) - channel 22 Bytes9.2 temperature difference (K)CRWTU
94Standby setpoint (cooling) - channel 2A2 Bytes9.1 temperature (°C)CRWTU
94Standby offset (cooling) - channel 2A2 Bytes9.2 temperature difference (K)CRWTU
94Standby setpoint (cooling) - channel 22 Bytes9.1 temperature (°C)CRWTU
94Standby offset (cooling) - channel 22 Bytes9.2 temperature difference (K)CRWTU
95Economy setpoint (heating) - channel 2A2 Bytes9.1 temperature (°C)CRWTU
95Economy offset (heating) - channel 2A2 Bytes9.2 temperature difference (K)CRWTU
95Economy setpoint (heating) - channel 22 Bytes9.1 temperature (°C)CRWTU
95Economy offset (heating) - channel 22 Bytes9.2 temperature difference (K)CRWTU
96Economy setpoint (cooling) - channel 2A2 Bytes9.1 temperature (°C)CRWTU
96Economy offset (cooling) - channel 2A2 Bytes9.2 temperature difference (K)CRWTU
96Economy setpoint (cooling) - channel 22 Bytes9.1 temperature (°C)CRWTU
96Economy offset (cooling) - channel 22 Bytes9.2 temperature difference (K)CRWTU
97Building protection setpoint (heating) - channel 2A2 Bytes9.1 temperature (°C)CRWTU
97Building protection setpoint (heating) - channel 22 Bytes9.1 temperature (°C)CRWTU
98Building protection setpoint (cooling) - channel 2A2 Bytes9.1 temperature (°C)CRWTU
98Building protection setpoint (cooling) - channel 22 Bytes9.1 temperature (°C)CRWTU
99Valve on/off command - channel 2B1 Bit1.1 switchCWTU
99Valve continuous command - channel 2B1 Byte5.1 percentage (0..100%)CWTU
99Valve on/off status - channel 2B1 Bit1.1 switchCRT
99Valve continuous status - channel 2B1 Byte5.1 percentage (0..100%)CRT
99On/off output command - channel 2B1 Bit1.1 switchCW
99Valve on/off cooling command - channel 2B1 Bit1.1 switchCWTU
99Valve continuous cooling command - channel 2B1 Byte5.1 percentage (0..100%)CWTU
99Valve on/off cooling status - channel 2B1 Bit1.1 switchCRT
99Valve continuous cooling status - channel 2B1 Byte5.1 percentage (0..100%)CRT
100Valve disable from bus - channel 2B1 Bit1.3 enableCW
100Cooling valve disable from bus - channel 2B1 Bit1.3 enableCW
101Enable forced mode from bus - channel 2B1 Bit1.3 enableCW
101Enable cooling forced mode from bus - channel 2B1 Bit1.3 enableCW
102Temperature control alarm - channel 2B1 Bit1.5 alarmCRT
103Room temperature 1 (from bus) - channel 2B2 Bytes9.1 temperature (°C)CWT
104Room temperature 2 (from bus) - channel 2B2 Bytes9.1 temperature (°C)CWT
105Floor surface temperature (from bus) - channel 2B2 Bytes9.1 temperature (°C)CWT
106Anticondensation sensor (from bus) - channel 2B1 Bit1.1 switchCWT
107Windows contact sensor (from bus) - channel 2B1 Bit1.19 window/doorCWT
108Presence sensor (from bus) - channel 2B1 Bit1.18 occupancyCWT
109HVAC mode in - channel 2B1 Byte20.102 HVAC modeCW
110HVAC manual mode - channel 2B1 Byte20.102 HVAC modeCW
111Chrono active status - channel 2B1 Bit1.11 stateCRWTU
112HVAC mode out - channel 2B1 Byte20.102 HVAC modeCRT
113Actual setpoint - channel 2B2 Bytes9.1 temperature (°C)CRT
114Manual setpoint - channel 2B2 Bytes9.1 temperature (°C)CW
115Manual setpoint active status - channel 2B1 Bit1.11 stateCRWTU
116Comfort setpoint (heating) - channel 2B2 Bytes9.1 temperature (°C)CRWTU
116Input setpoint - channel 2B2 Bytes9.1 temperature (°C)CRWTU
117Comfort setpoint (cooling) - channel 2B2 Bytes9.1 temperature (°C)CRWTU
118Standby setpoint (heating) - channel 2B2 Bytes9.1 temperature (°C)CRWTU
118Standby offset (heating) - channel 2B2 Bytes9.2 temperature difference (K)CRWTU
119Standby setpoint (cooling) - channel 2B2 Bytes9.1 temperature (°C)CRWTU
119Standby offset (cooling) - channel 2B2 Bytes9.2 temperature difference (K)CRWTU
120Economy setpoint (heating) - channel 2B2 Bytes9.1 temperature (°C)CRWTU
120Economy offset (heating) - channel 2B2 Bytes9.2 temperature difference (K)CRWTU
121Economy setpoint (cooling) - channel 2B2 Bytes9.1 temperature (°C)CRWTU
121Economy offset (cooling) - channel 2B2 Bytes9.2 temperature difference (K)CRWTU
122Building protection setpoint (heating) - channel 2B2 Bytes9.1 temperature (°C)CRWTU
123Building protection setpoint (cooling) - channel 2B2 Bytes9.1 temperature (°C)CRWTU
124Valve on/off command - channel 3A1 Bit1.1 switchCWTU
124Valve continuous command - channel 3A1 Byte5.1 percentage (0..100%)CWTU
124Valve on/off status - channel 3A1 Bit1.1 switchCRT
124Valve continuous status - channel 3A1 Byte5.1 percentage (0..100%)CRT
124On/off output command - channel 3A1 Bit1.1 switchCW
124Valve on/off heating command - channel 3A1 Bit1.1 switchCWTU
124Valve continuous heating command - channel 3A1 Byte5.1 percentage (0..100%)CWTU
124Valve on/off heating status - channel 3A1 Bit1.1 switchCRT
124Valve continuous heating status - channel 3A1 Byte5.1 percentage (0..100%)CRT
125Valve disable from bus - channel 3A1 Bit1.3 enableCW
125Heating valve disable from bus - channel 3A1 Bit1.3 enableCW
126Enable forced mode from bus - channel 3A1 Bit1.3 enableCW
126Enable heating forced mode from bus - channel 3A1 Bit1.3 enableCW
127Temperature control alarm - channel 3A1 Bit1.5 alarmCRT
127Temperature control alarm - channel 31 Bit1.5 alarmCRT
128Room temperature 1 (from bus) - channel 3A2 Bytes9.1 temperature (°C)CWT
128Room temperature 1 (from bus) - channel 32 Bytes9.1 temperature (°C)CWT
129Room temperature 2 (from bus) - channel 3A2 Bytes9.1 temperature (°C)CWT
129Room temperature 2 (from bus) - channel 32 Bytes9.1 temperature (°C)CWT
130Floor surface temperature (from bus) - channel 3A2 Bytes9.1 temperature (°C)CWT
130Floor surface temperature (from bus) - channel 32 Bytes9.1 temperature (°C)CWT
131Anticondensation sensor (from bus) - channel 3A1 Bit1.1 switchCWT
131Anticondensation sensor (from bus) - channel 31 Bit1.1 switchCWT
132Windows contact sensor (from bus) - channel 3A1 Bit1.19 window/doorCWT
132Windows contact sensor (from bus) - channel 31 Bit1.19 window/doorCWT
133Presence sensor (from bus) - channel 3A1 Bit1.18 occupancyCWT
133Presence sensor (from bus) - channel 31 Bit1.18 occupancyCWT
134HVAC mode in - channel 3A1 Byte20.102 HVAC modeCW
134HVAC mode in - channel 31 Byte20.102 HVAC modeCW
135HVAC manual mode - channel 3A1 Byte20.102 HVAC modeCW
135HVAC manual mode - channel 31 Byte20.102 HVAC modeCW
136Chrono active status - channel 3A1 Bit1.11 stateCRWTU
136Chrono active status - channel 31 Bit1.11 stateCRWTU
137HVAC mode out - channel 3A1 Byte20.102 HVAC modeCRT
137HVAC mode out - channel 31 Byte20.102 HVAC modeCRT
138Actual setpoint - channel 3A2 Bytes9.1 temperature (°C)CRT
138Actual setpoint - channel 32 Bytes9.1 temperature (°C)CRT
139Manual setpoint - channel 3A2 Bytes9.1 temperature (°C)CW
139Manual setpoint - channel 32 Bytes9.1 temperature (°C)CW
140Manual setpoint active status - channel 3A1 Bit1.11 stateCRWTU
140Manual setpoint active status - channel 31 Bit1.11 stateCRWTU
141Input setpoint - channel 3A2 Bytes9.1 temperature (°C)CRWTU
141Comfort setpoint (heating) - channel 3A2 Bytes9.1 temperature (°C)CRWTU
141Input setpoint - channel 32 Bytes9.1 temperature (°C)CRWTU
141Comfort setpoint (heating) - channel 32 Bytes9.1 temperature (°C)CRWTU
142Comfort setpoint (cooling) - channel 3A2 Bytes9.1 temperature (°C)CRWTU
142Comfort setpoint (cooling) - channel 32 Bytes9.1 temperature (°C)CRWTU
143Standby setpoint (heating) - channel 3A2 Bytes9.1 temperature (°C)CRWTU
143Standby offset (heating) - channel 3A2 Bytes9.2 temperature difference (K)CRWTU
143Standby setpoint (heating) - channel 32 Bytes9.1 temperature (°C)CRWTU
143Standby offset (heating) - channel 32 Bytes9.2 temperature difference (K)CRWTU
144Standby setpoint (cooling) - channel 3A2 Bytes9.1 temperature (°C)CRWTU
144Standby offset (cooling) - channel 3A2 Bytes9.2 temperature difference (K)CRWTU
144Standby setpoint (cooling) - channel 32 Bytes9.1 temperature (°C)CRWTU
144Standby offset (cooling) - channel 32 Bytes9.2 temperature difference (K)CRWTU
145Economy setpoint (heating) - channel 3A2 Bytes9.1 temperature (°C)CRWTU
145Economy offset (heating) - channel 3A2 Bytes9.2 temperature difference (K)CRWTU
145Economy setpoint (heating) - channel 32 Bytes9.1 temperature (°C)CRWTU
145Economy offset (heating) - channel 32 Bytes9.2 temperature difference (K)CRWTU
146Economy setpoint (cooling) - channel 3A2 Bytes9.1 temperature (°C)CRWTU
146Economy offset (cooling) - channel 3A2 Bytes9.2 temperature difference (K)CRWTU
146Economy setpoint (cooling) - channel 32 Bytes9.1 temperature (°C)CRWTU
146Economy offset (cooling) - channel 32 Bytes9.2 temperature difference (K)CRWTU
147Building protection setpoint (heating) - channel 3A2 Bytes9.1 temperature (°C)CRWTU
147Building protection setpoint (heating) - channel 32 Bytes9.1 temperature (°C)CRWTU
148Building protection setpoint (cooling) - channel 3A2 Bytes9.1 temperature (°C)CRWTU
148Building protection setpoint (cooling) - channel 32 Bytes9.1 temperature (°C)CRWTU
149Valve on/off command - channel 3B1 Bit1.1 switchCWTU
149Valve continuous command - channel 3B1 Byte5.1 percentage (0..100%)CWTU
149Valve on/off status - channel 3B1 Bit1.1 switchCRT
149Valve continuous status - channel 3B1 Byte5.1 percentage (0..100%)CRT
149On/off output command - channel 3B1 Bit1.1 switchCW
149Valve on/off cooling command - channel 3B1 Bit1.1 switchCWTU
149Valve continuous cooling command - channel 3B1 Byte5.1 percentage (0..100%)CWTU
149Valve on/off cooling status - channel 3B1 Bit1.1 switchCRT
149Valve continuous cooling status - channel 3B1 Byte5.1 percentage (0..100%)CRT
150Valve disable from bus - channel 3B1 Bit1.3 enableCW
150Cooling valve disable from bus - channel 3B1 Bit1.3 enableCW
151Enable forced mode from bus - channel 3B1 Bit1.3 enableCW
151Enable cooling forced mode from bus - channel 3B1 Bit1.3 enableCW
152Temperature control alarm - channel 3B1 Bit1.5 alarmCRT
153Room temperature 1 (from bus) - channel 3B2 Bytes9.1 temperature (°C)CWT
154Room temperature 2 (from bus) - channel 3B2 Bytes9.1 temperature (°C)CWT
155Floor surface temperature (from bus) - channel 3B2 Bytes9.1 temperature (°C)CWT
156Anticondensation sensor (from bus) - channel 3B1 Bit1.1 switchCWT
157Windows contact sensor (from bus) - channel 3B1 Bit1.19 window/doorCWT
158Presence sensor (from bus) - channel 3B1 Bit1.18 occupancyCWT
159HVAC mode in - channel 3B1 Byte20.102 HVAC modeCW
160HVAC manual mode - channel 3B1 Byte20.102 HVAC modeCW
161Chrono active status - channel 3B1 Bit1.11 stateCRWTU
162HVAC mode out - channel 3B1 Byte20.102 HVAC modeCRT
163Actual setpoint - channel 3B2 Bytes9.1 temperature (°C)CRT
164Manual setpoint - channel 3B2 Bytes9.1 temperature (°C)CW
165Manual setpoint active status - channel 3B1 Bit1.11 stateCRWTU
166Input setpoint - channel 3B2 Bytes9.1 temperature (°C)CRWTU
166Comfort setpoint (heating) - channel 3B2 Bytes9.1 temperature (°C)CRWTU
167Comfort setpoint (cooling) - channel 3B2 Bytes9.1 temperature (°C)CRWTU
168Standby setpoint (heating) - channel 3B2 Bytes9.1 temperature (°C)CRWTU
168Standby offset (heating) - channel 3B2 Bytes9.2 temperature difference (K)CRWTU
169Standby setpoint (cooling) - channel 3B2 Bytes9.1 temperature (°C)CRWTU
169Standby offset (cooling) - channel 3B2 Bytes9.2 temperature difference (K)CRWTU
170Economy setpoint (heating) - channel 3B2 Bytes9.1 temperature (°C)CRWTU
170Economy offset (heating) - channel 3B2 Bytes9.2 temperature difference (K)CRWTU
171Economy setpoint (cooling) - channel 3B2 Bytes9.1 temperature (°C)CRWTU
171Economy offset (cooling) - channel 3B2 Bytes9.2 temperature difference (K)CRWTU
172Building protection setpoint (heating) - channel 3B2 Bytes9.1 temperature (°C)CRWTU
173Building protection setpoint (cooling) - channel 3B2 Bytes9.1 temperature (°C)CRWTU
174Valve on/off command - channel 4A1 Bit1.1 switchCWTU
174Valve continuous command - channel 4A1 Byte5.1 percentage (0..100%)CWTU
174Valve on/off status - channel 4A1 Bit1.1 switchCRT
174Valve continuous status - channel 4A1 Byte5.1 percentage (0..100%)CRT
174On/off output command - channel 4A1 Bit1.1 switchCW
174Valve on/off heating command - channel 4A1 Bit1.1 switchCWTU
174Valve continuous heating command - channel 4A1 Byte5.1 percentage (0..100%)CWTU
174Valve on/off heating status - channel 4A1 Bit1.1 switchCRT
174Valve continuous heating status - channel 4A1 Byte5.1 percentage (0..100%)CRT
175Valve disable from bus - channel 4A1 Bit1.3 enableCW
175Heating valve disable from bus - channel 4A1 Bit1.3 enableCW
176Enable forced mode from bus - channel 4A1 Bit1.3 enableCW
176Enable heating forced mode from bus - channel 4A1 Bit1.3 enableCW
177Temperature control alarm - channel 4A1 Bit1.5 alarmCRT
177Temperature control alarm - channel 41 Bit1.5 alarmCRT
178Room temperature 1 (from bus) - channel 4A2 Bytes9.1 temperature (°C)CWT
178Room temperature 1 (from bus) - channel 42 Bytes9.1 temperature (°C)CWT
179Room temperature 2 (from bus) - channel 4A2 Bytes9.1 temperature (°C)CWT
179Room temperature 2 (from bus) - channel 42 Bytes9.1 temperature (°C)CWT
180Floor surface temperature (from bus) - channel 4A2 Bytes9.1 temperature (°C)CWT
180Floor surface temperature (from bus) - channel 42 Bytes9.1 temperature (°C)CWT
181Anticondensation sensor (from bus) - channel 4A1 Bit1.1 switchCWT
181Anticondensation sensor (from bus) - channel 41 Bit1.1 switchCWT
182Windows contact sensor (from bus) - channel 4A1 Bit1.19 window/doorCWT
182Windows contact sensor (from bus) - channel 41 Bit1.19 window/doorCWT
183Presence sensor (from bus) - channel 4A1 Bit1.18 occupancyCWT
183Presence sensor (from bus) - channel 41 Bit1.18 occupancyCWT
184HVAC mode in - channel 4A1 Byte20.102 HVAC modeCW
184HVAC mode in - channel 41 Byte20.102 HVAC modeCW
185HVAC manual mode - channel 4A1 Byte20.102 HVAC modeCW
185HVAC manual mode - channel 41 Byte20.102 HVAC modeCW
186Chrono active status - channel 4A1 Bit1.11 stateCRWTU
186Chrono active status - channel 41 Bit1.11 stateCRWTU
187HVAC mode out - channel 4A1 Byte20.102 HVAC modeCRT
187HVAC mode out - channel 41 Byte20.102 HVAC modeCRT
188Actual setpoint - channel 4A2 Bytes9.1 temperature (°C)CRT
188Actual setpoint - channel 42 Bytes9.1 temperature (°C)CRT
189Manual setpoint - channel 4A2 Bytes9.1 temperature (°C)CW
189Manual setpoint - channel 42 Bytes9.1 temperature (°C)CW
190Manual setpoint active status - channel 4A1 Bit1.11 stateCRWTU
190Manual setpoint active status - channel 41 Bit1.11 stateCRWTU
191Input setpoint - channel 4A2 Bytes9.1 temperature (°C)CRWTU
191Comfort setpoint (heating) - channel 4A2 Bytes9.1 temperature (°C)CRWTU
191Input setpoint - channel 42 Bytes9.1 temperature (°C)CRWTU
191Comfort setpoint (heating) - channel 42 Bytes9.1 temperature (°C)CRWTU
192Comfort setpoint (cooling) - channel 4A2 Bytes9.1 temperature (°C)CRWTU
192Comfort setpoint (cooling) - channel 42 Bytes9.1 temperature (°C)CRWTU
193Standby setpoint (heating) - channel 4A2 Bytes9.1 temperature (°C)CRWTU
193Standby offset (heating) - channel 4A2 Bytes9.2 temperature difference (K)CRWTU
193Standby setpoint (heating) - channel 42 Bytes9.1 temperature (°C)CRWTU
193Standby offset (heating) - channel 42 Bytes9.2 temperature difference (K)CRWTU
194Standby setpoint (cooling) - channel 4A2 Bytes9.1 temperature (°C)CRWTU
194Standby offset (cooling) - channel 4A2 Bytes9.2 temperature difference (K)CRWTU
194Standby setpoint (cooling) - channel 42 Bytes9.1 temperature (°C)CRWTU
194Standby offset (cooling) - channel 42 Bytes9.2 temperature difference (K)CRWTU
195Economy setpoint (heating) - channel 4A2 Bytes9.1 temperature (°C)CRWTU
195Economy offset (heating) - channel 4A2 Bytes9.2 temperature difference (K)CRWTU
195Economy setpoint (heating) - channel 42 Bytes9.1 temperature (°C)CRWTU
195Economy offset (heating) - channel 42 Bytes9.2 temperature difference (K)CRWTU
196Economy setpoint (cooling) - channel 4A2 Bytes9.1 temperature (°C)CRWTU
196Economy offset (cooling) - channel 4A2 Bytes9.2 temperature difference (K)CRWTU
196Economy setpoint (cooling) - channel 42 Bytes9.1 temperature (°C)CRWTU
196Economy offset (cooling) - channel 42 Bytes9.2 temperature difference (K)CRWTU
197Building protection setpoint (heating) - channel 4A2 Bytes9.1 temperature (°C)CRWTU
197Building protection setpoint (heating) - channel 42 Bytes9.1 temperature (°C)CRWTU
198Building protection setpoint (cooling) - channel 4A2 Bytes9.1 temperature (°C)CRWTU
198Building protection setpoint (cooling) - channel 42 Bytes9.1 temperature (°C)CRWTU
199Valve on/off command - channel 4B1 Bit1.1 switchCWTU
199Valve continuous command - channel 4B1 Byte5.1 percentage (0..100%)CWTU
199Valve on/off status - channel 4B1 Bit1.1 switchCRT
199Valve continuous status - channel 4B1 Byte5.1 percentage (0..100%)CRT
199On/off output command - channel 4B1 Bit1.1 switchCW
199Valve on/off cooling command - channel 4B1 Bit1.1 switchCWTU
199Valve continuous cooling command - channel 4B1 Byte5.1 percentage (0..100%)CWTU
199Valve on/off cooling status - channel 4B1 Bit1.1 switchCRT
199Valve continuous cooling status - channel 4B1 Byte5.1 percentage (0..100%)CRT
200Valve disable from bus - channel 4B1 Bit1.3 enableCW
200Cooling valve disable from bus - channel 4B1 Bit1.3 enableCW
201Enable forced mode from bus - channel 4B1 Bit1.3 enableCW
201Enable cooling forced mode from bus - channel 4B1 Bit1.3 enableCW
202Temperature control alarm - channel 4B1 Bit1.5 alarmCRT
203Room temperature 1 (from bus) - channel 4B2 Bytes9.1 temperature (°C)CWT
204Room temperature 2 (from bus) - channel 4B2 Bytes9.1 temperature (°C)CWT
205Floor surface temperature (from bus) - channel 4B2 Bytes9.1 temperature (°C)CWT
206Anticondensation sensor (from bus) - channel 4B1 Bit1.1 switchCWT
207Windows contact sensor (from bus) - channel 4B1 Bit1.19 window/doorCWT
208Presence sensor (from bus) - channel 4B1 Bit1.18 occupancyCWT
209HVAC mode in - channel 4B1 Byte20.102 HVAC modeCW
210HVAC manual mode - channel 4B1 Byte20.102 HVAC modeCW
211Chrono active status - channel 4B1 Bit1.11 stateCRWTU
212HVAC mode out - channel 4B1 Byte20.102 HVAC modeCRT
213Actual setpoint - channel 4B2 Bytes9.1 temperature (°C)CRT
214Manual setpoint - channel 4B2 Bytes9.1 temperature (°C)CW
215Manual setpoint active status - channel 4B1 Bit1.11 stateCRWTU
216Input setpoint - channel 4B2 Bytes9.1 temperature (°C)CRWTU
216Comfort setpoint (heating) - channel 4B2 Bytes9.1 temperature (°C)CRWTU
217Comfort setpoint (cooling) - channel 4B2 Bytes9.1 temperature (°C)CRWTU
218Standby setpoint (heating) - channel 4B2 Bytes9.1 temperature (°C)CRWTU
218Standby offset (heating) - channel 4B2 Bytes9.2 temperature difference (K)CRWTU
219Standby setpoint (cooling) - channel 4B2 Bytes9.1 temperature (°C)CRWTU
219Standby offset (cooling) - channel 4B2 Bytes9.2 temperature difference (K)CRWTU
220Economy setpoint (heating) - channel 4B2 Bytes9.1 temperature (°C)CRWTU
220Economy offset (heating) - channel 4B2 Bytes9.2 temperature difference (K)CRWTU
221Economy setpoint (cooling) - channel 4B2 Bytes9.1 temperature (°C)CRWTU
221Economy offset (cooling) - channel 4B2 Bytes9.2 temperature difference (K)CRWTU
222Building protection setpoint (heating) - channel 4B2 Bytes9.1 temperature (°C)CRWTU
223Building protection setpoint (cooling) - channel 4B2 Bytes9.1 temperature (°C)CRWTU
224Logic function 1 - Input 11 Bit1.1 switchCWTU
225Logic function 1 - Input 21 Bit1.1 switchCWTU
226Logic function 1 - Input 31 Bit1.1 switchCWTU
227Logic function 1 - Input 41 Bit1.1 switchCWTU
228Logic function 1 - Output1 Bit1.1 switchCRT
229Logic function 2 - Input 11 Bit1.1 switchCWTU
230Logic function 2 - Input 21 Bit1.1 switchCWTU
231Logic function 2 - Input 31 Bit1.1 switchCWTU
232Logic function 2 - Input 41 Bit1.1 switchCWTU
233Logic function 2 - Output1 Bit1.1 switchCRT
234Logic function 3 - Input 11 Bit1.1 switchCWTU
235Logic function 3 - Input 21 Bit1.1 switchCWTU
236Logic function 3 - Input 31 Bit1.1 switchCWTU
237Logic function 3 - Input 41 Bit1.1 switchCWTU
238Logic function 3 - Output1 Bit1.1 switchCRT
239Logic function 4 - Input 11 Bit1.1 switchCWTU
240Logic function 4 - Input 21 Bit1.1 switchCWTU
241Logic function 4 - Input 31 Bit1.1 switchCWTU
242Logic function 4 - Input 41 Bit1.1 switchCWTU
243Logic function 4 - Output1 Bit1.1 switchCRT
Parameters (114)
ParameterTypeDefault
Installation type - channel 1list2 independent channels
Energy request send on initializationlistno
Cyclic sending intervallistno sending
Manual operationlistenabled
Disable from buslistno
Delay after bus voltage recoverytime400
Command object timeouttime300
Command read on initlistno
Restore auto mode timetime900
Energy request on delay [s]unsignedInt 0…2550
Functionlistheating
Heating/cooling changeoverlistfrom bus
Actuator typelistNC (normally closed)
Short circuit controllistdisabled
Output activation delaylistdisabled
Output delaylist15 s
Digital sensors timeouttime300
Window contactlistdisabled
Presence sensorlistdisabled
Changeoveor read on initializationlistno
Power status feedbacklistdisabled
Signallistnot inverted
Setpoint cyclic sending intervallistno sending
Valve protection functionlistdisabled
Frequencylistonce a week
Time intervallist10 s
Energy requestlistdisabled
Analog sensors timeouttime300
Logic functionlistdisabled
Logic operationlistOR
Output cyclic transmission intervallistno sending
Logic object 1listdisabled
Logic object 2listdisabled
Logic object 3listdisabled
Logic object 4listdisabled
Logic object 1 negatedlistno
Logic object 2 negatedlistno
Logic object 3 negatedlistno
Logic object 4 negatedlistno
Logic object 1 read at startuplistno
Logic object 2 read at startuplistno
Logic object 3 read at startuplistno
Logic object 4 read at startuplistno
Logic object 1 default valuelistnone
Logic object 2 default valuelistnone
Logic object 3 default valuelistnone
Logic object 4 default valuelistnone
Logic functionslistdisabled
Channel 1Alistdisabled
Functionlistheating and cooling
Command communication object formatlistoutput status [DPT 1.001]
Valve position after timeoutlistoff
Valve position after timeoutunsignedInt 0…10050
Interlock functionlistdisabled
Valve opening time [s]unsignedInt 0…255100
Setpoint managementlistabsolute
Room temperature 1listdisabled
Room temperature 2listdisabled
Floor surface temperaturelistdisabled
Anticondensation sensorlistdisabled
Cyclic reading intervallistno reading
Relative weight (T1 / T2)list50% / 50%
End time manual setpointlisttill first telegram from bus
Signal disable from buslistnot inverted
Temperature setpoint [°C]float 10…5021
Standby temperature offset [0.1 K]signedInt -50…-10-30
Economy temperature offset [0.1 K]signedInt -80…-10-50
Building protection temperature [°C]float 2…107
Comfort temperature setpoint [°C]float 10…5021
Control typelist2 points hysteresis
Heating typelistfloor radiant panels
Positionlistbelow
Hysteresislist0.3 K
Min change of value to send [%]unsignedInt 0…10010
PWM cycle time [min]unsignedInt 1…25515
Proportional band [0.1 K]unsignedInt 0…25530
Integral time [min]unsignedInt 0…255240
Min control value [%]unsignedInt 0…3015
Max control value [%]unsignedInt 70…10085
Surface temperature limitationlistdisabled
Upper temperature limit [° C]unsignedInt 20…4029
Hysteresis [K]list0.3 K
Enables forced mode from buslistno
Valve position in forced modelistoff
Enables valve position feedbacklistno
Valve position in forced mode [%]unsignedInt 0…10050
Temperature setpoint [°C]float 10…5023
Comfort temperature setpoint [°C]float 10…5023
Standby temperature offset [0.1 K]signedInt 10…5030
Economy temperature offset [0.1 K]signedInt 10…8050
Building protection temperature [°C]float 20…5036
Cooling typelistfloor radiant panels
Positionlistabove
Anticondensation protectionlistdisabled
Channel 1Blistdisabled
Regulatorlistdisabled
Windows contact functionlistdisabled
Presence sensors functionlistdisabled
Presence sensors uselistcomfort extension
Withlistchannel 1A
Wait time to building protection modetime60
Absence time to switch HVAC modetime60
Thermostat modeslistcomfort - standby
Installation type - channel 2list2 independent channels
Channel 2Alistdisabled
Channel 2Blistdisabled
Installation type - channel 3list2 independent channels
Channel 3Alistdisabled
Channel 3Blistdisabled
Installation type - channel 4list2 independent channels
Channel 4Alistdisabled
Channel 4Blistdisabled
Supply voltagelist230 Vac
Dead band [0.1 K]signedInt 10…5020

Version history

ApplicationApp noFingerprintFirst seenSizeFile
APEKHE1TP 0.1 latest$4845CAC32026-11-25175 KBDownload

About this file

This is the official ETS product database for the Ekinex S.p.A. Actuator-controller 8 channels for electrothermal valve drives (EK-HE1-TP), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.