| 0 | Heating/cooling changeover command (2 pipes) | | 1 Bit | 1.100 heating/cooling | CWTU |
| 1 | Heating/cooling changeover status (2 pipes) | | 1 Bit | 1.100 heating/cooling | CRT |
| 2 | Heating/cooling changeover command (4 pipes) - channel 1 | | 1 Bit | 1.100 heating/cooling | CWTU |
| 3 | Heating/cooling changeover status (4 pipes) - channel 1 | | 1 Bit | 1.100 heating/cooling | CRT |
| 4 | Heating/cooling changeover command (4 pipes) - channel 2 | | 1 Bit | 1.100 heating/cooling | CWTU |
| 5 | Heating/cooling changeover status (4 pipes) - channel 2 | | 1 Bit | 1.100 heating/cooling | CRT |
| 6 | Heating/cooling changeover command (4 pipes) - channel 3 | | 1 Bit | 1.100 heating/cooling | CWTU |
| 7 | Heating/cooling changeover status (4 pipes) - channel 3 | | 1 Bit | 1.100 heating/cooling | CRT |
| 8 | Heating/cooling changeover command (4 pipes) - channel 4 | | 1 Bit | 1.100 heating/cooling | CWTU |
| 9 | Heating/cooling changeover status (4 pipes) - channel 4 | | 1 Bit | 1.100 heating/cooling | CRT |
| 10 | Enable general forced mode from bus | | 1 Bit | 1.3 enable | CW |
| 13 | Test mode activated | | 1 Bit | 1.3 enable | CRT |
| 14 | Energy request (heating) | | 1 Bit | 1.1 switch | CRT |
| 15 | Energy request (cooling) | | 1 Bit | 1.1 switch | CRT |
| 16 | Technical alarm | | 1 Bit | 1.5 alarm | CRT |
| 17 | Communication alarm | | 1 Bit | 1.5 alarm | CRT |
| 18 | Thermal generator lock alarm | | 1 Bit | 1.5 alarm | CW |
| 19 | Short circuit alarm | | 1 Bit | 1.5 alarm | CRT |
| 20 | Power off alarm output 1A, 1B, 2A and 2B | | 1 Bit | 1.5 alarm | CRT |
| 21 | Power off alarm output 3A, 3B, 4A and 4B | | 1 Bit | 1.5 alarm | CRT |
| 22 | Alarm text | | 14 Bytes | 16.0 Character String (ASCII) | CRT |
| 23 | Disable front keyboard | | 1 Bit | 1.3 enable | CW |
| 24 | Valve on/off command - channel 1A | | 1 Bit | 1.1 switch | CWTU |
| 24 | Valve on/off status - channel 1A | | 1 Bit | 1.1 switch | CRT |
| 24 | Valve on/off heating command - channel 1A | | 1 Bit | 1.1 switch | CWTU |
| 24 | Valve continuous heating command - channel 1A | | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 24 | Valve continuous command - channel 1A | | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 24 | Valve continuous status - channel 1A | | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 24 | Valve continuous heating status - channel 1A | | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 24 | Valve on/off heating status - channel 1A | | 1 Bit | 1.1 switch | CRT |
| 24 | On/off output command - channel 1A | | 1 Bit | 1.1 switch | CW |
| 25 | Valve disable from bus - channel 1A | | 1 Bit | 1.3 enable | CW |
| 25 | Heating valve disable from bus - channel 1A | | 1 Bit | 1.3 enable | CW |
| 26 | Enable forced mode from bus - channel 1A | | 1 Bit | 1.3 enable | CW |
| 26 | Enable heating forced mode from bus - channel 1A | | 1 Bit | 1.3 enable | CW |
| 27 | Temperature control alarm - channel 1A | | 1 Bit | 1.5 alarm | CRT |
| 27 | Temperature control alarm - channel 1 | | 1 Bit | 1.5 alarm | CRT |
| 28 | Room temperature 1 (from bus) - channel 1A | | 2 Bytes | 9.1 temperature (°C) | CWT |
| 28 | Room temperature 1 (from bus) - channel 1 | | 2 Bytes | 9.1 temperature (°C) | CWT |
| 29 | Room temperature 2 (from bus) - channel 1A | | 2 Bytes | 9.1 temperature (°C) | CWT |
| 29 | Room temperature 2 (from bus) - channel 1 | | 2 Bytes | 9.1 temperature (°C) | CWT |
| 30 | Floor surface temperature (from bus) - channel 1A | | 2 Bytes | 9.1 temperature (°C) | CWT |
| 30 | Floor surface temperature (from bus) - channel 1 | | 2 Bytes | 9.1 temperature (°C) | CWT |
| 31 | Anticondensation sensor (from bus) - channel 1A | | 1 Bit | 1.1 switch | CWT |
| 31 | Anticondensation sensor (from bus) - channel 1 | | 1 Bit | 1.1 switch | CWT |
| 32 | Windows contact sensor (from bus) - channel 1A | | 1 Bit | 1.19 window/door | CWT |
| 32 | Windows contact sensor (from bus) - channel 1 | | 1 Bit | 1.19 window/door | CWT |
| 33 | Presence sensor (from bus) - channel 1A | | 1 Bit | 1.18 occupancy | CWT |
| 33 | Presence sensor (from bus) - channel 1 | | 1 Bit | 1.18 occupancy | CWT |
| 34 | HVAC mode in - channel 1A | | 1 Byte | 20.102 HVAC mode | CW |
| 34 | HVAC mode in - channel 1 | | 1 Byte | 20.102 HVAC mode | CW |
| 35 | HVAC manual mode - channel 1A | | 1 Byte | 20.102 HVAC mode | CW |
| 35 | HVAC manual mode - channel 1 | | 1 Byte | 20.102 HVAC mode | CW |
| 36 | Chrono active status - channel 1A | | 1 Bit | 1.11 state | CRWTU |
| 36 | Chrono active status - channel 1 | | 1 Bit | 1.11 state | CRWTU |
| 37 | HVAC mode out - channel 1A | | 1 Byte | 20.102 HVAC mode | CRT |
| 37 | HVAC mode out - channel 1 | | 1 Byte | 20.102 HVAC mode | CRT |
| 38 | Actual setpoint - channel 1A | | 2 Bytes | 9.1 temperature (°C) | CRT |
| 38 | Actual setpoint - channel 1 | | 2 Bytes | 9.1 temperature (°C) | CRT |
| 39 | Manual setpoint - channel 1A | | 2 Bytes | 9.1 temperature (°C) | CW |
| 39 | Manual setpoint - channel 1 | | 2 Bytes | 9.1 temperature (°C) | CW |
| 40 | Manual setpoint active status - channel 1A | | 1 Bit | 1.11 state | CRWTU |
| 40 | Manual setpoint active status - channel 1 | | 1 Bit | 1.11 state | CRWTU |
| 41 | Comfort setpoint (heating) - channel 1A | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 41 | Input setpoint - channel 1A | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 41 | Input setpoint - channel 1 | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 41 | Comfort setpoint (heating) - channel 1 | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 42 | Comfort setpoint (cooling) - channel 1A | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 42 | Comfort setpoint (cooling) - channel 1 | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 43 | Standby setpoint (heating) - channel 1A | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 43 | Standby offset (heating) - channel 1A | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 43 | Standby setpoint (heating) - channel 1 | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 43 | Standby offset (heating) - channel 1 | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 44 | Standby setpoint (cooling) - channel 1A | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 44 | Standby offset (cooling) - channel 1A | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 44 | Standby offset (cooling) - channel 1 | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 44 | Standby setpoint (cooling) - channel 1 | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 45 | Economy setpoint (heating) - channel 1A | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 45 | Economy offset (heating) - channel 1A | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 45 | Economy setpoint (heating) - channel 1 | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 45 | Economy offset (heating) - channel 1 | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 46 | Economy setpoint (cooling) - channel 1A | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 46 | Economy offset (cooling) - channel 1A | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 46 | Economy offset (cooling) - channel 1 | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 46 | Economy setpoint (cooling) - channel 1 | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 47 | Building protection setpoint (heating) - channel 1A | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 47 | Building protection setpoint (heating) - channel 1 | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 48 | Building protection setpoint (cooling) - channel 1A | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 48 | Building protection setpoint (cooling) - channel 1 | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 49 | Valve on/off command - channel 1B | | 1 Bit | 1.1 switch | CWTU |
| 49 | Valve continuous command - channel 1B | | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 49 | Valve on/off cooling command - channel 1B | | 1 Bit | 1.1 switch | CWTU |
| 49 | Valve continuous cooling command - channel 1B | | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 49 | Valve on/off status - channel 1B | | 1 Bit | 1.1 switch | CRT |
| 49 | Valve continuous status - channel 1B | | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 49 | Valve on/off cooling status - channel 1B | | 1 Bit | 1.1 switch | CRT |
| 49 | Valve continuous cooling status - channel 1B | | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 49 | On/off output command - channel 1B | | 1 Bit | 1.1 switch | CW |
| 50 | Valve disable from bus - channel 1B | | 1 Bit | 1.3 enable | CW |
| 50 | Cooling valve disable from bus - channel 1B | | 1 Bit | 1.3 enable | CW |
| 51 | Enable forced mode from bus - channel 1B | | 1 Bit | 1.3 enable | CW |
| 51 | Enable cooling forced mode from bus - channel 1B | | 1 Bit | 1.3 enable | CW |
| 52 | Temperature control alarm - channel 1B | | 1 Bit | 1.5 alarm | CRT |
| 53 | Room temperature 1 (from bus) - channel 1B | | 2 Bytes | 9.1 temperature (°C) | CWT |
| 54 | Room temperature 2 (from bus) - channel 1B | | 2 Bytes | 9.1 temperature (°C) | CWT |
| 55 | Floor surface temperature (from bus) - channel 1B | | 2 Bytes | 9.1 temperature (°C) | CWT |
| 56 | Anticondensation sensor (from bus) - channel 1B | | 1 Bit | 1.1 switch | CWT |
| 57 | Windows contact sensor (from bus) - channel 1B | | 1 Bit | 1.19 window/door | CWT |
| 58 | Presence sensor (from bus) - channel 1B | | 1 Bit | 1.18 occupancy | CWT |
| 59 | HVAC mode in - channel 1B | | 1 Byte | 20.102 HVAC mode | CW |
| 60 | HVAC manual mode - channel 1B | | 1 Byte | 20.102 HVAC mode | CW |
| 61 | Chrono active status - channel 1B | | 1 Bit | 1.11 state | CRWTU |
| 62 | HVAC mode out - channel 1B | | 1 Byte | 20.102 HVAC mode | CRT |
| 63 | Actual setpoint - channel 1B | | 2 Bytes | 9.1 temperature (°C) | CRT |
| 64 | Manual setpoint - channel 1B | | 2 Bytes | 9.1 temperature (°C) | CW |
| 65 | Manual setpoint active status - channel 1B | | 1 Bit | 1.11 state | CRWTU |
| 66 | Input setpoint - channel 1B | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 66 | Comfort setpoint (heating) - channel 1B | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 67 | Comfort setpoint (cooling) - channel 1B | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 68 | Standby setpoint (heating) - channel 1B | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 68 | Standby offset (heating) - channel 1B | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 69 | Standby setpoint (cooling) - channel 1B | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 69 | Standby offset (cooling) - channel 1B | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 70 | Economy setpoint (heating) - channel 1B | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 70 | Economy offset (heating) - channel 1B | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 71 | Economy setpoint (cooling) - channel 1B | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 71 | Economy offset (cooling) - channel 1B | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 72 | Building protection setpoint (heating) - channel 1B | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 73 | Building protection setpoint (cooling) - channel 1B | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 74 | Valve on/off command - channel 2A | | 1 Bit | 1.1 switch | CWTU |
| 74 | Valve continuous command - channel 2A | | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 74 | Valve on/off status - channel 2A | | 1 Bit | 1.1 switch | CRT |
| 74 | Valve continuous status - channel 2A | | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 74 | On/off output command - channel 2A | | 1 Bit | 1.1 switch | CW |
| 74 | Valve on/off heating command - channel 2A | | 1 Bit | 1.1 switch | CWTU |
| 74 | Valve continuous heating command - channel 2A | | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 74 | Valve on/off heating status - channel 2A | | 1 Bit | 1.1 switch | CRT |
| 74 | Valve continuous heating status - channel 2A | | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 75 | Valve disable from bus - channel 2A | | 1 Bit | 1.3 enable | CW |
| 75 | Heating valve disable from bus - channel 2A | | 1 Bit | 1.3 enable | CW |
| 76 | Enable forced mode from bus - channel 2A | | 1 Bit | 1.3 enable | CW |
| 76 | Enable heating forced mode from bus - channel 2A | | 1 Bit | 1.3 enable | CW |
| 77 | Temperature control alarm - channel 2A | | 1 Bit | 1.5 alarm | CRT |
| 77 | Temperature control alarm - channel 2 | | 1 Bit | 1.5 alarm | CRT |
| 78 | Room temperature 1 (from bus) - channel 2A | | 2 Bytes | 9.1 temperature (°C) | CWT |
| 78 | Room temperature 1 (from bus) - channel 2 | | 2 Bytes | 9.1 temperature (°C) | CWT |
| 79 | Room temperature 2 (from bus) - channel 2A | | 2 Bytes | 9.1 temperature (°C) | CWT |
| 79 | Room temperature 2 (from bus) - channel 2 | | 2 Bytes | 9.1 temperature (°C) | CWT |
| 80 | Floor surface temperature (from bus) - channel 2A | | 2 Bytes | 9.1 temperature (°C) | CWT |
| 80 | Floor surface temperature (from bus) - channel 2 | | 2 Bytes | 9.1 temperature (°C) | CWT |
| 81 | Anticondensation sensor (from bus) - channel 2A | | 1 Bit | 1.1 switch | CWT |
| 81 | Anticondensation sensor (from bus) - channel 2 | | 1 Bit | 1.1 switch | CWT |
| 82 | Windows contact sensor (from bus) - channel 2A | | 1 Bit | 1.19 window/door | CWT |
| 82 | Windows contact sensor (from bus) - channel 2 | | 1 Bit | 1.19 window/door | CWT |
| 83 | Presence sensor (from bus) - channel 2A | | 1 Bit | 1.18 occupancy | CWT |
| 83 | Presence sensor (from bus) - channel 2 | | 1 Bit | 1.18 occupancy | CWT |
| 84 | HVAC mode in - channel 2A | | 1 Byte | 20.102 HVAC mode | CW |
| 84 | HVAC mode in - channel 2 | | 1 Byte | 20.102 HVAC mode | CW |
| 85 | HVAC manual mode - channel 2A | | 1 Byte | 20.102 HVAC mode | CW |
| 85 | HVAC manual mode - channel 2 | | 1 Byte | 20.102 HVAC mode | CW |
| 86 | Chrono active status - channel 2A | | 1 Bit | 1.11 state | CRWTU |
| 86 | Chrono active status - channel 2 | | 1 Bit | 1.11 state | CRWTU |
| 87 | HVAC mode out - channel 2A | | 1 Byte | 20.102 HVAC mode | CRT |
| 87 | HVAC mode out - channel 2 | | 1 Byte | 20.102 HVAC mode | CRT |
| 88 | Actual setpoint - channel 2A | | 2 Bytes | 9.1 temperature (°C) | CRT |
| 88 | Actual setpoint - channel 2 | | 2 Bytes | 9.1 temperature (°C) | CRT |
| 89 | Manual setpoint - channel 2A | | 2 Bytes | 9.1 temperature (°C) | CW |
| 89 | Manual setpoint - channel 2 | | 2 Bytes | 9.1 temperature (°C) | CW |
| 90 | Manual setpoint active status - channel 2A | | 1 Bit | 1.11 state | CRWTU |
| 90 | Manual setpoint active status - channel 2 | | 1 Bit | 1.11 state | CRWTU |
| 91 | Comfort setpoint (heating) - channel 2A | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 91 | Input setpoint - channel 2A | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 91 | Comfort setpoint (heating) - channel 2 | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 91 | Input setpoint - channel 2 | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 92 | Comfort setpoint (cooling) - channel 2A | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 92 | Comfort setpoint (cooling) - channel 2 | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 93 | Standby setpoint (heating) - channel 2A | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 93 | Standby offset (heating) - channel 2A | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 93 | Standby setpoint (heating) - channel 2 | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 93 | Standby offset (heating) - channel 2 | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 94 | Standby setpoint (cooling) - channel 2A | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 94 | Standby offset (cooling) - channel 2A | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 94 | Standby setpoint (cooling) - channel 2 | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 94 | Standby offset (cooling) - channel 2 | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 95 | Economy setpoint (heating) - channel 2A | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 95 | Economy offset (heating) - channel 2A | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 95 | Economy setpoint (heating) - channel 2 | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 95 | Economy offset (heating) - channel 2 | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 96 | Economy setpoint (cooling) - channel 2A | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 96 | Economy offset (cooling) - channel 2A | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 96 | Economy setpoint (cooling) - channel 2 | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 96 | Economy offset (cooling) - channel 2 | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 97 | Building protection setpoint (heating) - channel 2A | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 97 | Building protection setpoint (heating) - channel 2 | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 98 | Building protection setpoint (cooling) - channel 2A | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 98 | Building protection setpoint (cooling) - channel 2 | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 99 | Valve on/off command - channel 2B | | 1 Bit | 1.1 switch | CWTU |
| 99 | Valve continuous command - channel 2B | | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 99 | Valve on/off status - channel 2B | | 1 Bit | 1.1 switch | CRT |
| 99 | Valve continuous status - channel 2B | | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 99 | On/off output command - channel 2B | | 1 Bit | 1.1 switch | CW |
| 99 | Valve on/off cooling command - channel 2B | | 1 Bit | 1.1 switch | CWTU |
| 99 | Valve continuous cooling command - channel 2B | | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 99 | Valve on/off cooling status - channel 2B | | 1 Bit | 1.1 switch | CRT |
| 99 | Valve continuous cooling status - channel 2B | | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 100 | Valve disable from bus - channel 2B | | 1 Bit | 1.3 enable | CW |
| 100 | Cooling valve disable from bus - channel 2B | | 1 Bit | 1.3 enable | CW |
| 101 | Enable forced mode from bus - channel 2B | | 1 Bit | 1.3 enable | CW |
| 101 | Enable cooling forced mode from bus - channel 2B | | 1 Bit | 1.3 enable | CW |
| 102 | Temperature control alarm - channel 2B | | 1 Bit | 1.5 alarm | CRT |
| 103 | Room temperature 1 (from bus) - channel 2B | | 2 Bytes | 9.1 temperature (°C) | CWT |
| 104 | Room temperature 2 (from bus) - channel 2B | | 2 Bytes | 9.1 temperature (°C) | CWT |
| 105 | Floor surface temperature (from bus) - channel 2B | | 2 Bytes | 9.1 temperature (°C) | CWT |
| 106 | Anticondensation sensor (from bus) - channel 2B | | 1 Bit | 1.1 switch | CWT |
| 107 | Windows contact sensor (from bus) - channel 2B | | 1 Bit | 1.19 window/door | CWT |
| 108 | Presence sensor (from bus) - channel 2B | | 1 Bit | 1.18 occupancy | CWT |
| 109 | HVAC mode in - channel 2B | | 1 Byte | 20.102 HVAC mode | CW |
| 110 | HVAC manual mode - channel 2B | | 1 Byte | 20.102 HVAC mode | CW |
| 111 | Chrono active status - channel 2B | | 1 Bit | 1.11 state | CRWTU |
| 112 | HVAC mode out - channel 2B | | 1 Byte | 20.102 HVAC mode | CRT |
| 113 | Actual setpoint - channel 2B | | 2 Bytes | 9.1 temperature (°C) | CRT |
| 114 | Manual setpoint - channel 2B | | 2 Bytes | 9.1 temperature (°C) | CW |
| 115 | Manual setpoint active status - channel 2B | | 1 Bit | 1.11 state | CRWTU |
| 116 | Comfort setpoint (heating) - channel 2B | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 116 | Input setpoint - channel 2B | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 117 | Comfort setpoint (cooling) - channel 2B | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 118 | Standby setpoint (heating) - channel 2B | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 118 | Standby offset (heating) - channel 2B | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 119 | Standby setpoint (cooling) - channel 2B | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 119 | Standby offset (cooling) - channel 2B | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 120 | Economy setpoint (heating) - channel 2B | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 120 | Economy offset (heating) - channel 2B | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 121 | Economy setpoint (cooling) - channel 2B | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 121 | Economy offset (cooling) - channel 2B | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 122 | Building protection setpoint (heating) - channel 2B | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 123 | Building protection setpoint (cooling) - channel 2B | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 124 | Valve on/off command - channel 3A | | 1 Bit | 1.1 switch | CWTU |
| 124 | Valve continuous command - channel 3A | | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 124 | Valve on/off status - channel 3A | | 1 Bit | 1.1 switch | CRT |
| 124 | Valve continuous status - channel 3A | | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 124 | On/off output command - channel 3A | | 1 Bit | 1.1 switch | CW |
| 124 | Valve on/off heating command - channel 3A | | 1 Bit | 1.1 switch | CWTU |
| 124 | Valve continuous heating command - channel 3A | | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 124 | Valve on/off heating status - channel 3A | | 1 Bit | 1.1 switch | CRT |
| 124 | Valve continuous heating status - channel 3A | | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 125 | Valve disable from bus - channel 3A | | 1 Bit | 1.3 enable | CW |
| 125 | Heating valve disable from bus - channel 3A | | 1 Bit | 1.3 enable | CW |
| 126 | Enable forced mode from bus - channel 3A | | 1 Bit | 1.3 enable | CW |
| 126 | Enable heating forced mode from bus - channel 3A | | 1 Bit | 1.3 enable | CW |
| 127 | Temperature control alarm - channel 3A | | 1 Bit | 1.5 alarm | CRT |
| 127 | Temperature control alarm - channel 3 | | 1 Bit | 1.5 alarm | CRT |
| 128 | Room temperature 1 (from bus) - channel 3A | | 2 Bytes | 9.1 temperature (°C) | CWT |
| 128 | Room temperature 1 (from bus) - channel 3 | | 2 Bytes | 9.1 temperature (°C) | CWT |
| 129 | Room temperature 2 (from bus) - channel 3A | | 2 Bytes | 9.1 temperature (°C) | CWT |
| 129 | Room temperature 2 (from bus) - channel 3 | | 2 Bytes | 9.1 temperature (°C) | CWT |
| 130 | Floor surface temperature (from bus) - channel 3A | | 2 Bytes | 9.1 temperature (°C) | CWT |
| 130 | Floor surface temperature (from bus) - channel 3 | | 2 Bytes | 9.1 temperature (°C) | CWT |
| 131 | Anticondensation sensor (from bus) - channel 3A | | 1 Bit | 1.1 switch | CWT |
| 131 | Anticondensation sensor (from bus) - channel 3 | | 1 Bit | 1.1 switch | CWT |
| 132 | Windows contact sensor (from bus) - channel 3A | | 1 Bit | 1.19 window/door | CWT |
| 132 | Windows contact sensor (from bus) - channel 3 | | 1 Bit | 1.19 window/door | CWT |
| 133 | Presence sensor (from bus) - channel 3A | | 1 Bit | 1.18 occupancy | CWT |
| 133 | Presence sensor (from bus) - channel 3 | | 1 Bit | 1.18 occupancy | CWT |
| 134 | HVAC mode in - channel 3A | | 1 Byte | 20.102 HVAC mode | CW |
| 134 | HVAC mode in - channel 3 | | 1 Byte | 20.102 HVAC mode | CW |
| 135 | HVAC manual mode - channel 3A | | 1 Byte | 20.102 HVAC mode | CW |
| 135 | HVAC manual mode - channel 3 | | 1 Byte | 20.102 HVAC mode | CW |
| 136 | Chrono active status - channel 3A | | 1 Bit | 1.11 state | CRWTU |
| 136 | Chrono active status - channel 3 | | 1 Bit | 1.11 state | CRWTU |
| 137 | HVAC mode out - channel 3A | | 1 Byte | 20.102 HVAC mode | CRT |
| 137 | HVAC mode out - channel 3 | | 1 Byte | 20.102 HVAC mode | CRT |
| 138 | Actual setpoint - channel 3A | | 2 Bytes | 9.1 temperature (°C) | CRT |
| 138 | Actual setpoint - channel 3 | | 2 Bytes | 9.1 temperature (°C) | CRT |
| 139 | Manual setpoint - channel 3A | | 2 Bytes | 9.1 temperature (°C) | CW |
| 139 | Manual setpoint - channel 3 | | 2 Bytes | 9.1 temperature (°C) | CW |
| 140 | Manual setpoint active status - channel 3A | | 1 Bit | 1.11 state | CRWTU |
| 140 | Manual setpoint active status - channel 3 | | 1 Bit | 1.11 state | CRWTU |
| 141 | Input setpoint - channel 3A | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 141 | Comfort setpoint (heating) - channel 3A | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 141 | Input setpoint - channel 3 | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 141 | Comfort setpoint (heating) - channel 3 | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 142 | Comfort setpoint (cooling) - channel 3A | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 142 | Comfort setpoint (cooling) - channel 3 | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 143 | Standby setpoint (heating) - channel 3A | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 143 | Standby offset (heating) - channel 3A | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 143 | Standby setpoint (heating) - channel 3 | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 143 | Standby offset (heating) - channel 3 | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 144 | Standby setpoint (cooling) - channel 3A | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 144 | Standby offset (cooling) - channel 3A | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 144 | Standby setpoint (cooling) - channel 3 | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 144 | Standby offset (cooling) - channel 3 | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 145 | Economy setpoint (heating) - channel 3A | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 145 | Economy offset (heating) - channel 3A | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 145 | Economy setpoint (heating) - channel 3 | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 145 | Economy offset (heating) - channel 3 | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 146 | Economy setpoint (cooling) - channel 3A | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 146 | Economy offset (cooling) - channel 3A | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 146 | Economy setpoint (cooling) - channel 3 | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 146 | Economy offset (cooling) - channel 3 | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 147 | Building protection setpoint (heating) - channel 3A | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 147 | Building protection setpoint (heating) - channel 3 | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 148 | Building protection setpoint (cooling) - channel 3A | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 148 | Building protection setpoint (cooling) - channel 3 | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 149 | Valve on/off command - channel 3B | | 1 Bit | 1.1 switch | CWTU |
| 149 | Valve continuous command - channel 3B | | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 149 | Valve on/off status - channel 3B | | 1 Bit | 1.1 switch | CRT |
| 149 | Valve continuous status - channel 3B | | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 149 | On/off output command - channel 3B | | 1 Bit | 1.1 switch | CW |
| 149 | Valve on/off cooling command - channel 3B | | 1 Bit | 1.1 switch | CWTU |
| 149 | Valve continuous cooling command - channel 3B | | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 149 | Valve on/off cooling status - channel 3B | | 1 Bit | 1.1 switch | CRT |
| 149 | Valve continuous cooling status - channel 3B | | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 150 | Valve disable from bus - channel 3B | | 1 Bit | 1.3 enable | CW |
| 150 | Cooling valve disable from bus - channel 3B | | 1 Bit | 1.3 enable | CW |
| 151 | Enable forced mode from bus - channel 3B | | 1 Bit | 1.3 enable | CW |
| 151 | Enable cooling forced mode from bus - channel 3B | | 1 Bit | 1.3 enable | CW |
| 152 | Temperature control alarm - channel 3B | | 1 Bit | 1.5 alarm | CRT |
| 153 | Room temperature 1 (from bus) - channel 3B | | 2 Bytes | 9.1 temperature (°C) | CWT |
| 154 | Room temperature 2 (from bus) - channel 3B | | 2 Bytes | 9.1 temperature (°C) | CWT |
| 155 | Floor surface temperature (from bus) - channel 3B | | 2 Bytes | 9.1 temperature (°C) | CWT |
| 156 | Anticondensation sensor (from bus) - channel 3B | | 1 Bit | 1.1 switch | CWT |
| 157 | Windows contact sensor (from bus) - channel 3B | | 1 Bit | 1.19 window/door | CWT |
| 158 | Presence sensor (from bus) - channel 3B | | 1 Bit | 1.18 occupancy | CWT |
| 159 | HVAC mode in - channel 3B | | 1 Byte | 20.102 HVAC mode | CW |
| 160 | HVAC manual mode - channel 3B | | 1 Byte | 20.102 HVAC mode | CW |
| 161 | Chrono active status - channel 3B | | 1 Bit | 1.11 state | CRWTU |
| 162 | HVAC mode out - channel 3B | | 1 Byte | 20.102 HVAC mode | CRT |
| 163 | Actual setpoint - channel 3B | | 2 Bytes | 9.1 temperature (°C) | CRT |
| 164 | Manual setpoint - channel 3B | | 2 Bytes | 9.1 temperature (°C) | CW |
| 165 | Manual setpoint active status - channel 3B | | 1 Bit | 1.11 state | CRWTU |
| 166 | Input setpoint - channel 3B | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 166 | Comfort setpoint (heating) - channel 3B | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 167 | Comfort setpoint (cooling) - channel 3B | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 168 | Standby setpoint (heating) - channel 3B | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 168 | Standby offset (heating) - channel 3B | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 169 | Standby setpoint (cooling) - channel 3B | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 169 | Standby offset (cooling) - channel 3B | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 170 | Economy setpoint (heating) - channel 3B | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 170 | Economy offset (heating) - channel 3B | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 171 | Economy setpoint (cooling) - channel 3B | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 171 | Economy offset (cooling) - channel 3B | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 172 | Building protection setpoint (heating) - channel 3B | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 173 | Building protection setpoint (cooling) - channel 3B | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 174 | Valve on/off command - channel 4A | | 1 Bit | 1.1 switch | CWTU |
| 174 | Valve continuous command - channel 4A | | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 174 | Valve on/off status - channel 4A | | 1 Bit | 1.1 switch | CRT |
| 174 | Valve continuous status - channel 4A | | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 174 | On/off output command - channel 4A | | 1 Bit | 1.1 switch | CW |
| 174 | Valve on/off heating command - channel 4A | | 1 Bit | 1.1 switch | CWTU |
| 174 | Valve continuous heating command - channel 4A | | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 174 | Valve on/off heating status - channel 4A | | 1 Bit | 1.1 switch | CRT |
| 174 | Valve continuous heating status - channel 4A | | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 175 | Valve disable from bus - channel 4A | | 1 Bit | 1.3 enable | CW |
| 175 | Heating valve disable from bus - channel 4A | | 1 Bit | 1.3 enable | CW |
| 176 | Enable forced mode from bus - channel 4A | | 1 Bit | 1.3 enable | CW |
| 176 | Enable heating forced mode from bus - channel 4A | | 1 Bit | 1.3 enable | CW |
| 177 | Temperature control alarm - channel 4A | | 1 Bit | 1.5 alarm | CRT |
| 177 | Temperature control alarm - channel 4 | | 1 Bit | 1.5 alarm | CRT |
| 178 | Room temperature 1 (from bus) - channel 4A | | 2 Bytes | 9.1 temperature (°C) | CWT |
| 178 | Room temperature 1 (from bus) - channel 4 | | 2 Bytes | 9.1 temperature (°C) | CWT |
| 179 | Room temperature 2 (from bus) - channel 4A | | 2 Bytes | 9.1 temperature (°C) | CWT |
| 179 | Room temperature 2 (from bus) - channel 4 | | 2 Bytes | 9.1 temperature (°C) | CWT |
| 180 | Floor surface temperature (from bus) - channel 4A | | 2 Bytes | 9.1 temperature (°C) | CWT |
| 180 | Floor surface temperature (from bus) - channel 4 | | 2 Bytes | 9.1 temperature (°C) | CWT |
| 181 | Anticondensation sensor (from bus) - channel 4A | | 1 Bit | 1.1 switch | CWT |
| 181 | Anticondensation sensor (from bus) - channel 4 | | 1 Bit | 1.1 switch | CWT |
| 182 | Windows contact sensor (from bus) - channel 4A | | 1 Bit | 1.19 window/door | CWT |
| 182 | Windows contact sensor (from bus) - channel 4 | | 1 Bit | 1.19 window/door | CWT |
| 183 | Presence sensor (from bus) - channel 4A | | 1 Bit | 1.18 occupancy | CWT |
| 183 | Presence sensor (from bus) - channel 4 | | 1 Bit | 1.18 occupancy | CWT |
| 184 | HVAC mode in - channel 4A | | 1 Byte | 20.102 HVAC mode | CW |
| 184 | HVAC mode in - channel 4 | | 1 Byte | 20.102 HVAC mode | CW |
| 185 | HVAC manual mode - channel 4A | | 1 Byte | 20.102 HVAC mode | CW |
| 185 | HVAC manual mode - channel 4 | | 1 Byte | 20.102 HVAC mode | CW |
| 186 | Chrono active status - channel 4A | | 1 Bit | 1.11 state | CRWTU |
| 186 | Chrono active status - channel 4 | | 1 Bit | 1.11 state | CRWTU |
| 187 | HVAC mode out - channel 4A | | 1 Byte | 20.102 HVAC mode | CRT |
| 187 | HVAC mode out - channel 4 | | 1 Byte | 20.102 HVAC mode | CRT |
| 188 | Actual setpoint - channel 4A | | 2 Bytes | 9.1 temperature (°C) | CRT |
| 188 | Actual setpoint - channel 4 | | 2 Bytes | 9.1 temperature (°C) | CRT |
| 189 | Manual setpoint - channel 4A | | 2 Bytes | 9.1 temperature (°C) | CW |
| 189 | Manual setpoint - channel 4 | | 2 Bytes | 9.1 temperature (°C) | CW |
| 190 | Manual setpoint active status - channel 4A | | 1 Bit | 1.11 state | CRWTU |
| 190 | Manual setpoint active status - channel 4 | | 1 Bit | 1.11 state | CRWTU |
| 191 | Input setpoint - channel 4A | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 191 | Comfort setpoint (heating) - channel 4A | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 191 | Input setpoint - channel 4 | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 191 | Comfort setpoint (heating) - channel 4 | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 192 | Comfort setpoint (cooling) - channel 4A | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 192 | Comfort setpoint (cooling) - channel 4 | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 193 | Standby setpoint (heating) - channel 4A | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 193 | Standby offset (heating) - channel 4A | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 193 | Standby setpoint (heating) - channel 4 | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 193 | Standby offset (heating) - channel 4 | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 194 | Standby setpoint (cooling) - channel 4A | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 194 | Standby offset (cooling) - channel 4A | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 194 | Standby setpoint (cooling) - channel 4 | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 194 | Standby offset (cooling) - channel 4 | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 195 | Economy setpoint (heating) - channel 4A | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 195 | Economy offset (heating) - channel 4A | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 195 | Economy setpoint (heating) - channel 4 | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 195 | Economy offset (heating) - channel 4 | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 196 | Economy setpoint (cooling) - channel 4A | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 196 | Economy offset (cooling) - channel 4A | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 196 | Economy setpoint (cooling) - channel 4 | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 196 | Economy offset (cooling) - channel 4 | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 197 | Building protection setpoint (heating) - channel 4A | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 197 | Building protection setpoint (heating) - channel 4 | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 198 | Building protection setpoint (cooling) - channel 4A | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 198 | Building protection setpoint (cooling) - channel 4 | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 199 | Valve on/off command - channel 4B | | 1 Bit | 1.1 switch | CWTU |
| 199 | Valve continuous command - channel 4B | | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 199 | Valve on/off status - channel 4B | | 1 Bit | 1.1 switch | CRT |
| 199 | Valve continuous status - channel 4B | | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 199 | On/off output command - channel 4B | | 1 Bit | 1.1 switch | CW |
| 199 | Valve on/off cooling command - channel 4B | | 1 Bit | 1.1 switch | CWTU |
| 199 | Valve continuous cooling command - channel 4B | | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 199 | Valve on/off cooling status - channel 4B | | 1 Bit | 1.1 switch | CRT |
| 199 | Valve continuous cooling status - channel 4B | | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 200 | Valve disable from bus - channel 4B | | 1 Bit | 1.3 enable | CW |
| 200 | Cooling valve disable from bus - channel 4B | | 1 Bit | 1.3 enable | CW |
| 201 | Enable forced mode from bus - channel 4B | | 1 Bit | 1.3 enable | CW |
| 201 | Enable cooling forced mode from bus - channel 4B | | 1 Bit | 1.3 enable | CW |
| 202 | Temperature control alarm - channel 4B | | 1 Bit | 1.5 alarm | CRT |
| 203 | Room temperature 1 (from bus) - channel 4B | | 2 Bytes | 9.1 temperature (°C) | CWT |
| 204 | Room temperature 2 (from bus) - channel 4B | | 2 Bytes | 9.1 temperature (°C) | CWT |
| 205 | Floor surface temperature (from bus) - channel 4B | | 2 Bytes | 9.1 temperature (°C) | CWT |
| 206 | Anticondensation sensor (from bus) - channel 4B | | 1 Bit | 1.1 switch | CWT |
| 207 | Windows contact sensor (from bus) - channel 4B | | 1 Bit | 1.19 window/door | CWT |
| 208 | Presence sensor (from bus) - channel 4B | | 1 Bit | 1.18 occupancy | CWT |
| 209 | HVAC mode in - channel 4B | | 1 Byte | 20.102 HVAC mode | CW |
| 210 | HVAC manual mode - channel 4B | | 1 Byte | 20.102 HVAC mode | CW |
| 211 | Chrono active status - channel 4B | | 1 Bit | 1.11 state | CRWTU |
| 212 | HVAC mode out - channel 4B | | 1 Byte | 20.102 HVAC mode | CRT |
| 213 | Actual setpoint - channel 4B | | 2 Bytes | 9.1 temperature (°C) | CRT |
| 214 | Manual setpoint - channel 4B | | 2 Bytes | 9.1 temperature (°C) | CW |
| 215 | Manual setpoint active status - channel 4B | | 1 Bit | 1.11 state | CRWTU |
| 216 | Input setpoint - channel 4B | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 216 | Comfort setpoint (heating) - channel 4B | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 217 | Comfort setpoint (cooling) - channel 4B | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 218 | Standby setpoint (heating) - channel 4B | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 218 | Standby offset (heating) - channel 4B | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 219 | Standby setpoint (cooling) - channel 4B | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 219 | Standby offset (cooling) - channel 4B | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 220 | Economy setpoint (heating) - channel 4B | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 220 | Economy offset (heating) - channel 4B | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 221 | Economy setpoint (cooling) - channel 4B | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 221 | Economy offset (cooling) - channel 4B | | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 222 | Building protection setpoint (heating) - channel 4B | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 223 | Building protection setpoint (cooling) - channel 4B | | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 224 | Logic function 1 - Input 1 | | 1 Bit | 1.1 switch | CWTU |
| 225 | Logic function 1 - Input 2 | | 1 Bit | 1.1 switch | CWTU |
| 226 | Logic function 1 - Input 3 | | 1 Bit | 1.1 switch | CWTU |
| 227 | Logic function 1 - Input 4 | | 1 Bit | 1.1 switch | CWTU |
| 228 | Logic function 1 - Output | | 1 Bit | 1.1 switch | CRT |
| 229 | Logic function 2 - Input 1 | | 1 Bit | 1.1 switch | CWTU |
| 230 | Logic function 2 - Input 2 | | 1 Bit | 1.1 switch | CWTU |
| 231 | Logic function 2 - Input 3 | | 1 Bit | 1.1 switch | CWTU |
| 232 | Logic function 2 - Input 4 | | 1 Bit | 1.1 switch | CWTU |
| 233 | Logic function 2 - Output | | 1 Bit | 1.1 switch | CRT |
| 234 | Logic function 3 - Input 1 | | 1 Bit | 1.1 switch | CWTU |
| 235 | Logic function 3 - Input 2 | | 1 Bit | 1.1 switch | CWTU |
| 236 | Logic function 3 - Input 3 | | 1 Bit | 1.1 switch | CWTU |
| 237 | Logic function 3 - Input 4 | | 1 Bit | 1.1 switch | CWTU |
| 238 | Logic function 3 - Output | | 1 Bit | 1.1 switch | CRT |
| 239 | Logic function 4 - Input 1 | | 1 Bit | 1.1 switch | CWTU |
| 240 | Logic function 4 - Input 2 | | 1 Bit | 1.1 switch | CWTU |
| 241 | Logic function 4 - Input 3 | | 1 Bit | 1.1 switch | CWTU |
| 242 | Logic function 4 - Input 4 | | 1 Bit | 1.1 switch | CWTU |
| 243 | Logic function 4 - Output | | 1 Bit | 1.1 switch | CRT |