Ekinex S.p.A. EK-HC1-TP Fan-coil actuator/controller

Fan-coil actuator/controller EK-HC1-TP

Ekinex S.p.A. · Order number EK-HC1-TP · Heating, cooling and ventilation

EK-HC1-TP - Fan-coil actuator/controller (full version)

Download .knxprod APEKHC1TP 0.3 · 178 KB

Product

ManufacturerEkinex S.p.A.
Product nameFan-coil actuator/controller
Order numberEK-HC1-TP
Product textEK-HC1-TP - Fan-coil actuator/controller (full version)
HardwareFan-coil actuator/controller
MediumTwisted Pair
Bus current (mA)10
Rail mountedYes
Width (mm)72
RegistrationCertified · 2017-03-15
Languagesen-US, de-DE, fr-FR, it-IT
Catalog entryM-00B6_H-000028-1_HP-4843-03-6B5B_CI-EK.2DHC1.2DTP-1
Fingerprint6B5B
SHA-256721349c5e64f6d5b975c708ed38e4214aee76990a1e78a49fc2b6e65ee251890
First seen2026-11-25
Markets69 markets

Application program: APEKHC1TP 0.3

Application number$4843
Version0.3
Mask versionMV-0705 (7.5)
KNX Data SecureNo
Minimum ETS version5.0
Parameters357
Group objects158
Group objects (158)
NoNameFunctionSizeDPTFlags
0Fan continuous speed command1 Byte5.1 percentage (0..100%)CW
0First fan speed command1 Bit1.1 switchCW
0Fan continuous speed command counter1 Byte5.10 counter pulses (0..255)CW
0Fan continuous speed manual command1 Byte5.1 percentage (0..100%)CW
1Second fan speed command1 Bit1.1 switchCW
1Fan continuous speed manual counter1 Byte5.10 counter pulses (0..255)CW
2Third fan speed command1 Bit1.1 switchCW
3Heating valve command (on/off)1 Bit1.1 switchCW
3Heating valve command (PWM)1 Byte5.1 percentage (0..100%)CW
3Heating/cooling valve command (on/off)1 Bit1.1 switchCW
3Heating/cooling valve command (PWM)1 Byte5.1 percentage (0..100%)CW
4Cooling valve command (on/off)1 Bit1.1 switchCW
4Cooling valve command (PWM)1 Byte5.1 percentage (0..100%)CW
5Heating/cooling changeover command1 Bit1.100 cooling/heatingCW
6Test mode activated1 Bit1.3 enableCRT
7Actual fan speed %1 Byte5.1 percentage (0..100%)CRT
7Status 0-10V1 Byte5.1 percentage (0..100%)CRT
8Fan stopped status1 Bit1.1 switchCRT
9Speed V1 status1 Bit1.1 switchCRT
10Speed V2 status1 Bit1.1 switchCRT
11Speed V3 status1 Bit1.1 switchCRT
12Counter speed fan status1 Byte5.10 counter pulses (0..255)CRT
13Valve DO1 status1 Bit1.1 switchCRT
14Valve DO2 status1 Bit1.1 switchCRT
15Technical alarm1 Bit1.5 alarmCRT
16Communication alarm1 Bit1.5 alarmCRT
18Thermal generator locked1 Bit1.5 alarmCW
19Temperature control alarm1 Bit1.5 alarmCRT
20Antistratification temperature sensor (from input 1)2 Bytes9.1 temperature (°C)CRT
20Coil battery temperature sensor (from input 1)2 Bytes9.1 temperature (°C)CRT
20Room temperature sensor (from input 1)2 Bytes9.1 temperature (°C)CRT
20Outdoor temperature sensor (from input 1)2 Bytes9.1 temperature (°C)CRT
20Temperature value sensor (from input 1)2 Bytes9.1 temperature (°C)CRT
20Flow temperature sensor (from input 1)2 Bytes9.1 temperature (°C)CRT
21Temperature threshold 1 sensor (from input 1) - Switch1 Bit1.1 switchCRT
22Temperature threshold 2 sensor (from input 1) - Switch1 Bit1.1 switchCRT
23Antistratification temperature sensor (from input 2)2 Bytes9.1 temperature (°C)CRT
23Coil battery temperature sensor (from input 2)2 Bytes9.1 temperature (°C)CRT
23Room temperature sensor (from input 2)2 Bytes9.1 temperature (°C)CRT
23Outdoor temperature sensor (from input 2)2 Bytes9.1 temperature (°C)CRT
23Temperature value sensor (from input 2)2 Bytes9.1 temperature (°C)CRT
23Flow temperature sensor (from input 2)2 Bytes9.1 temperature (°C)CRT
24Temperature threshold 1 sensor (from input 2) - Switch1 Bit1.1 switchCRT
25Temperature threshold 2 sensor (from input 2) - Switch1 Bit1.1 switchCRT
26Antistratification temperature sensor (from input 3)2 Bytes9.1 temperature (°C)CRT
26Coil battery temperature sensor (from input 3)2 Bytes9.1 temperature (°C)CRT
26Room temperature sensor (from input 3)2 Bytes9.1 temperature (°C)CRT
26Outdoor temperature sensor (from input 3)2 Bytes9.1 temperature (°C)CRT
26Temperature value sensor (from input 3)2 Bytes9.1 temperature (°C)CRT
26Flow temperature sensor (from input 3)2 Bytes9.1 temperature (°C)CRT
27Temperature threshold 1 sensor (from input 3) - Switch1 Bit1.1 switchCRT
28Temperature threshold 2 sensor (from input 3) - Switch1 Bit1.1 switchCRT
29Window contact (from input 1)1 Bit1.19 window/doorCRT
29Drip tray contact (from input 1)1 Bit1.5 alarmCRT
29Generic contact (from input 1)1 Bit1.19 window/doorCRT
30Window contact (from input 2)1 Bit1.19 window/doorCRT
30Drip tray contact (from input 2)1 Bit1.5 alarmCRT
30Generic contact (from input 2)1 Bit1.19 window/doorCRT
31Window contact (from input 3)1 Bit1.19 window/doorCRT
31Drip tray contact (from input 3)1 Bit1.5 alarmCRT
31Generic contact (from input 3)1 Bit1.19 window/doorCRT
32Room temperature (from bus)2 Bytes9.1 temperature (°C)CW
33Outdoor temperature (from bus)2 Bytes9.1 temperature (°C)CW
34Coil battery temperature (from bus)2 Bytes9.1 temperature (°C)CW
35Antistratification temperature (from bus)2 Bytes9.1 temperature (°C)CW
36Water supply temperature (from bus)2 Bytes9.1 temperature (°C)CW
37Drip tray contact (from bus)1 Bit1.5 alarmCW
38Window contact 1 (from bus)1 Bit1.19 window/doorCW
39Window contact 2 (from bus)1 Bit1.19 window/doorCW
40Presence sensor 1 from bus1 Bit1.18 occupancyCW
41Presence sensor 2 from bus1 Bit1.18 occupancyCW
42Heating/cooling status out1 Bit1.100 cooling/heatingCRT
43Heating/cooling changeover command1 Bit1.100 cooling/heatingCW
44HVAC mode IN1 Byte20.102 HVAC modeCW
45HVAC manual mode1 Byte20.102 HVAC modeCW
46HVAC chrono mode active status1 Bit1.11 stateCRWTU
47HVAC mode OUT1 Byte20.102 HVAC modeCRT
48Actual setpoint2 Bytes9.1 temperature (°C)CRT
49Input setpoint2 Bytes9.1 temperature (°C)CW
50Comfort setpoint (heating)2 Bytes9.1 temperature (°C)CRWTU
51Comfort setpoint (cooling)2 Bytes9.1 temperature (°C)CRWTU
52Standby offset (heating)2 Bytes9.2 temperature difference (K)CRWTU
52Standby setpoint (heating)2 Bytes9.1 temperature (°C)CRWTU
53Standby offset (cooling)2 Bytes9.2 temperature difference (K)CRWTU
53Standby setpoint (cooling)2 Bytes9.1 temperature (°C)CRWTU
54Economy offset (heating)2 Bytes9.2 temperature difference (K)CRWTU
54Economy setpoint (heating)2 Bytes9.1 temperature (°C)CRWTU
55Economy offset (cooling)2 Bytes9.2 temperature difference (K)CRWTU
55Economy setpoint (cooling)2 Bytes9.1 temperature (°C)CRWTU
56Building protection (heating)2 Bytes9.1 temperature (°C)CRWTU
57Building protection (cooling)2 Bytes9.1 temperature (°C)CRWTU
58Manual/forced setpoint active status1 Bit1.11 stateCRWTU
59Manual setpoint2 Bytes9.1 temperature (°C)CRWTU
60Cooling compensation offset2 Bytes9.2 temperature difference (K)CRT
61Temperature controller output1 Byte5.1 percentage (0..100%)CRT
62Fan working time (hours)2 Bytes7.7 time (h)CRT
63Fan working time (seconds)4 Bytes13.100 time lag (s)CRT
64Filter change warning1 Bit1.5 alarmCRWT
65Fan disable from bus1 Bit1.3 enableCW
66Fan manual/auto status1 Bit1.11 stateCRWTU
67Heating/cooling valve disable from bus1 Bit1.3 enableCW
67Heating valve disable from bus1 Bit1.3 enableCW
68Cooling valve disable from bus1 Bit1.3 enableCW
69Auxiliary relais disable from bus1 Bit1.3 enableCW
70Auxiliary relais status1 Bit1.1 switchCRT
71Controller output forced from bus1 Byte5.1 percentage (0..100%)CW
72Controller output automatic/forced from bus1 Bit1.3 enableCW
73Drip tray status1 Bit1.5 alarmCRT
74Disable front keyboard1 Bit1.2 booleanCW
75Power off alarm1 Bit1.5 alarmCRT
76Output V1 from bus1 Bit1.1 switchCW
77Output V2 from bus1 Bit1.1 switchCW
78Output V3 from bus1 Bit1.1 switchCW
79Output DO1 from bus1 Bit1.1 switchCW
80Output DO2 from bus1 Bit1.1 switchCW
81Output 0-10V from bus1 Byte5.1 percentage (0..100%)CW
82Fan speed limit enable1 Bit1.3 enableCW
83Alarm text14 Bytes16.0 Character String (ASCII)CRT
84Logic function 1 - Input 11 Bit1.1 switchCWTU
85Logic function 1 - Input 21 Bit1.1 switchCWTU
86Logic function 1 - Input 31 Bit1.1 switchCWTU
87Logic function 1 - Input 41 Bit1.1 switchCWTU
88Logic function 1 - Output1 Bit1.1 switchCRT
89Logic function 2 - Input 11 Bit1.1 switchCWTU
90Logic function 2 - Input 21 Bit1.1 switchCWTU
91Logic function 2 - Input 31 Bit1.1 switchCWTU
92Logic function 2 - Input 41 Bit1.1 switchCWTU
93Logic function 2 - Output1 Bit1.1 switchCRT
94Logic function 3 - Input 11 Bit1.1 switchCWTU
95Logic function 3 - Input 21 Bit1.1 switchCWTU
96Logic function 3 - Input 31 Bit1.1 switchCWTU
97Logic function 3 - Input 41 Bit1.1 switchCWTU
98Logic function 3 - Output1 Bit1.1 switchCRT
99Logic function 4 - Input 11 Bit1.1 switchCWTU
100Logic function 4 - Input 21 Bit1.1 switchCWTU
101Logic function 4 - Input 31 Bit1.1 switchCWTU
102Logic function 4 - Input 41 Bit1.1 switchCWTU
103Logic function 4 - Output1 Bit1.1 switchCRT
104Logic function 5 - Input 11 Bit1.1 switchCWTU
105Logic function 5 - Input 21 Bit1.1 switchCWTU
106Logic function 5 - Input 31 Bit1.1 switchCWTU
107Logic function 5 - Input 41 Bit1.1 switchCWTU
108Logic function 5 - Output1 Bit1.1 switchCRT
109Logic function 6 - Input 11 Bit1.1 switchCWTU
110Logic function 6 - Input 21 Bit1.1 switchCWTU
111Logic function 6 - Input 31 Bit1.1 switchCWTU
112Logic function 6 - Input 41 Bit1.1 switchCWTU
113Logic function 6 - Output1 Bit1.1 switchCRT
114Logic function 7 - Input 11 Bit1.1 switchCWTU
115Logic function 7 - Input 21 Bit1.1 switchCWTU
116Logic function 7 - Input 31 Bit1.1 switchCWTU
117Logic function 7 - Input 41 Bit1.1 switchCWTU
118Logic function 7 - Output1 Bit1.1 switchCRT
119Logic function 8 - Input 11 Bit1.1 switchCWTU
120Logic function 8 - Input 21 Bit1.1 switchCWTU
121Logic function 8 - Input 31 Bit1.1 switchCWTU
122Logic function 8 - Input 41 Bit1.1 switchCWTU
123Logic function 8 - Output1 Bit1.1 switchCRT
Parameters (149)
ParameterTypeDefault
Delay after bus voltage recoverytime400
Contact typelistNO (normally open)
Debounce timetime20
Minimum change of value to send [K]float 0…50.5
Cyclic sending intervallistno sending
Threshold 1listnot active
Threshold 2listnot active
Value [°C]float -25…607
Value [°C]float -25…6045
Hysteresislist0.4 K
Digital sensors timeouttime300
Room temperaturelistdisabled
Antistratification temperaturelistdisabled
Outdoor temperaturelistdisabled
Coil temperaturelistdisabled
Flow temperaturelistdisabled
Window contact 1listdisabled
Window contact 2listdisabled
Presence sensor 1listdisabled
Presence sensor 2listdisabled
Filter typelistmedium
Signallistnot inverted
Applicationlistfan-coil
Functionlistheating
Distribution typelist2 pipes
Controllerlistexternal
Manual operationlistenabled
Disable from buslistno
Power status feedbacklistdisabled
Report filter changelistno
Ventilation Object formatlistpercentage [DPT 5.001]
Restore auto mode timetime900
Input 1listdisabled
Offsetlist0.0 °C
Input 2listdisabled
Input 3listdisabled
Communication Object timeouttime300
Analog sensors timeouttime300
Inputslistdifferent
Drip tray levellistdisabled
First speed threshold [%]unsignedInt 0…10010
Control typelist1 speed (relais)
Cold startlistno
Warm startlistno
Second speed threshold [%]unsignedInt 0…10040
Third speed threshold [%]unsignedInt 0…10070
Hysteresis [%]unsignedInt 0…305
Heat exchange coil temperatureunsignedInt 28…4035
Heat exchange coil temperatureunsignedInt 7…1812
Speed control low limit [%]unsignedInt 0…1000
Speed control high limit [%]unsignedInt 0…100100
2-sensor antistratificationlistdisabled
Disable from buslistdisabled
Temperature differentiallist2.00 K/m
Hysteresislist0.6 K
Start delaylist0 s
Stop delaylist0 s
Fan control feedbacklistdisabled
Control typeliston/off
Control can be disabled from buslistno
Valve position feedbacklistdisabled
Valve position after timeoutlistoff
PWM cycle timetime15
Min. control value [%]unsignedInt 0…3015
Max. control value [%]unsignedInt 70…10085
Valve protectionlistdisabled
Frequencylistonce a week
Time intervallist10 s
Auxiliary output typelistvalue from bus
Setpoint typelistrelative
Heating/cooling changeoverlistfrom bus
Temperature for changeover (heating)float 20…5035
Temperature for changeover (cooling)float 5…2016
Changeover cyclic sending intervallistno sending
Comfort setpoint [°C]float 10…5021
Standby offset [0.1 K]signedInt -50…-10-30
Economy offset [0.1 K]signedInt -80…-10-50
Building protection [°C]float 2…107
Proportional band [0.1 K]unsignedInt 0…25530
Integral time [min]unsignedInt 0…2550
Min change of value to send [%]unsignedInt 0…10010
Forced modelistno
Comfort setpoint [°C]float 10…5023
Standby offset [0.1 K]signedInt 10…5030
Economy offset [0.1 K]signedInt 10…8050
Building protection [°C]float 20…5036
Neutral zone [0.1 K]signedInt 10…5020
Summer compensationlistdisabled
Lowest external temperature [°C]unsignedInt 25…4025
Coefficientlist1 K each 4 K external temp. change
Min change to send valuelist0.6 K
Window contacts functionlistdisabled
Time to wait before HVAC changetime60
Presence sensors functionlistdisabled
Uselistcomfort extension
Modeslistcomfort - standby
In case of driplistclose valve and switch fan off
Drip controllistdisabled
Change filter warning after [weeks]unsignedInt 1…12816
Send warningliston filter change only
Send usage timelistno sending (only reading)
Cyclic sending intervallist24 h
Speed at timeoutlistspeed 1
Speed at timeoutlist20%
Output value at the first speedunsignedInt 0…10010
Output value at the second speedunsignedInt 0…10040
Output value at the third speedunsignedInt 0…10070
Communication Objectlistseparated
Valve Object formatlistoutput status [DPT 1.001]
First speed threshold [0.1K]unsignedInt 0…2550
Second speed threshold [0.1K]unsignedInt 0…25510
Third speed threshold [0.1K]unsignedInt 0…25520
Hysteresis [0.1K]list0.3 K
Temperature setpoint [°C]float 10…5021
Temperature setpoint [°C]float 10…5023
Fan speed limit from buslistnot limited
Setpoint CO typelistabsolute
Logic functionslistdisabled
Logic functionlistdisabled
Logic operationlistOR
Output cyclic sending intervallistno sending
Logic object 1listdisabled
Logic object 2listdisabled
Logic object 3listdisabled
Logic object 4listdisabled
Logic object 1 negatedlistno
Logic object 2 negatedlistno
Logic object 3 negatedlistno
Logic object 4 negatedlistno
Logic object 1 read at startuplistno
Logic object 2 read at startuplistno
Logic object 3 read at startuplistno
Logic object 4 read at startuplistno
Logic object 1 default valuelistnone
Logic object 2 default valuelistnone
Logic object 3 default valuelistnone
Logic object 4 default valuelistnone
Communication Object typelistseconds [DPT 13.100]
Speed output low limit [%]unsignedInt 0…1000
Speed output high limit [%]unsignedInt 0…100100
Minimum change of value to send [%]unsignedInt 0…305
RoomTemplistno
End of manual operationlistat first telegram from bus
Time-scheduled antistratificationlistdisabled
Frequencylist30 min
Time intervallist2 min
Fan controllistdepending on temperature
DO1 : Cyclic sending intervallistno sending
DO2: Cyclic sending intervallistno sending

Version history

ApplicationApp noFingerprintFirst seenSizeFile
APEKHC1TP 0.4 latest$4843CBEB2026-11-25178 KBDownload
APEKHC1TP 0.3$48436B5B2026-11-25178 KBDownload

About this file

This is the official ETS product database for the Ekinex S.p.A. Fan-coil actuator/controller (EK-HC1-TP), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Ekinex S.p.A.

All Ekinex S.p.A. products