Fan-coil actuator/controller EK-HA1-TP
Ekinex S.p.A. · Order number EK-HA1-TP · Heating, cooling and ventilation
EK-HA1-TP - Fan-coil actuator/controller
Download .knxprod APEKHA1TP 0.3 · 127 KB
Product
| Manufacturer | Ekinex S.p.A. |
|---|---|
| Product name | Fan-coil actuator/controller |
| Order number | EK-HA1-TP |
| Product text | EK-HA1-TP - Fan-coil actuator/controller |
| Hardware | Fan-coil actuator/controller |
| Medium | Twisted Pair |
| Bus current (mA) | 8 |
| Rail mounted | Yes |
| Width (mm) | 72 |
| Registration | Certified · 2016-02-25 |
| Languages | en-US, de-DE, fr-FR, it-IT |
| Catalog entry | M-00B6_H-000026-1_HP-4841-03-FFA0_CI-EK.2DHA1.2DTP-1 |
| Fingerprint | FFA0 |
| SHA-256 | 5f530df2e813b7750a1ca26a507695bbab7380ccbaa8563b20209f7ee9234721 |
| First seen | 2026-11-25 |
| Markets | 69 markets |
Application program: APEKHA1TP 0.3
| Application number | $4841 |
|---|---|
| Version | 0.3 |
| Mask version | MV-0705 (7.5) |
| KNX Data Secure | No |
| Minimum ETS version | 4.0 |
| Parameters | 350 |
| Group objects | 140 |
Group objects (140)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Fan continuous speed command | 1 Byte | 5.1 percentage (0..100%) | CW | |
| 0 | First fan speed command | 1 Bit | 1.1 switch | CW | |
| 0 | Fan continuous speed command counter | 1 Byte | 5.10 counter pulses (0..255) | CW | |
| 0 | Fan continuous speed manual command | 1 Byte | 5.1 percentage (0..100%) | CW | |
| 1 | Second fan speed command | 1 Bit | 1.1 switch | CW | |
| 1 | Fan continuous speed manual counter | 1 Byte | 5.10 counter pulses (0..255) | CW | |
| 2 | Third fan speed command | 1 Bit | 1.1 switch | CW | |
| 3 | Heating valve command (on/off) | 1 Bit | 1.1 switch | CW | |
| 3 | Heating valve command (PWM) | 1 Byte | 5.1 percentage (0..100%) | CW | |
| 3 | Heating/cooling valve command (on/off) | 1 Bit | 1.1 switch | CW | |
| 3 | Heating/cooling valve command (PWM) | 1 Byte | 5.1 percentage (0..100%) | CW | |
| 4 | Cooling valve command (on/off) | 1 Bit | 1.1 switch | CW | |
| 4 | Cooling valve command (PWM) | 1 Byte | 5.1 percentage (0..100%) | CW | |
| 5 | Heating/cooling changeover command | 1 Bit | 1.100 heating/cooling | CW | |
| 8 | Fan stopped | 1 Bit | 1.1 switch | CRT | |
| 9 | First speed fan speed status | 1 Bit | 1.1 switch | CRT | |
| 10 | Second speed fan speed status | 1 Bit | 1.1 switch | CRT | |
| 11 | Third speed fan speed status | 1 Bit | 1.1 switch | CRT | |
| 12 | Counter speed fan status | 1 Byte | 5.10 counter pulses (0..255) | CRT | |
| 13 | Heating/cooling valve status | 1 Bit | 1.1 switch | CRT | |
| 13 | Heating valve status | 1 Bit | 1.1 switch | CRT | |
| 14 | Cooling valve status | 1 Bit | 1.1 switch | CRT | |
| 15 | Technical alarm | 1 Bit | 1.5 alarm | CRT | |
| 16 | Communication alarm | 1 Bit | 1.5 alarm | CRT | |
| 18 | Thermal generator locked | 1 Bit | 1.5 alarm | CW | |
| 19 | Temperature control alarm | 1 Bit | 1.5 alarm | CRT | |
| 20 | Antistratification temperature sensor (from input 1) | 2 Bytes | 9.1 temperature (°C) | CRT | |
| 20 | Coil battery temperature sensor (from input 1) | 2 Bytes | 9.1 temperature (°C) | CRT | |
| 20 | Room temperature sensor (from input 1) | 2 Bytes | 9.1 temperature (°C) | CRT | |
| 20 | Outdoor temperature sensor (from input 1) | 2 Bytes | 9.1 temperature (°C) | CRT | |
| 20 | Temperature value sensor (from input 1) | 2 Bytes | 9.1 temperature (°C) | CRT | |
| 20 | Flow temperature sensor (from input 1) | 2 Bytes | 9.1 temperature (°C) | CRT | |
| 21 | Temperature threshold 1 sensor 1 - Switch | 1 Bit | 1.1 switch | CRT | |
| 22 | Temperature threshold 2 sensor 1 - Switch | 1 Bit | 1.1 switch | CRT | |
| 23 | Antistratification temperature sensor (from input 2) | 2 Bytes | 9.1 temperature (°C) | CRT | |
| 23 | Coil battery temperature sensor (from input 2) | 2 Bytes | 9.1 temperature (°C) | CRT | |
| 23 | Room temperature sensor (from input 2) | 2 Bytes | 9.1 temperature (°C) | CRT | |
| 23 | Outdoor temperature sensor (from input 2) | 2 Bytes | 9.1 temperature (°C) | CRT | |
| 23 | Temperature value sensor (from input 2) | 2 Bytes | 9.1 temperature (°C) | CRT | |
| 23 | Flow temperature sensor (from input 2) | 2 Bytes | 9.1 temperature (°C) | CRT | |
| 24 | Temperature threshold 1 sensor 2 - Switch | 1 Bit | 1.1 switch | CRT | |
| 25 | Temperature threshold 2 sensor 2 - Switch | 1 Bit | 1.1 switch | CRT | |
| 29 | Window contact (from input 1) | 1 Bit | 1.19 window/door | CRT | |
| 29 | Drip tray contact (from input 1) | 1 Bit | 1.5 alarm | CRT | |
| 29 | Generic contact (from input 1) | 1 Bit | 1.1 switch | CRT | |
| 30 | Window contact (from input 2) | 1 Bit | 1.19 window/door | CRT | |
| 30 | Drip tray contact (from input 2) | 1 Bit | 1.5 alarm | CRT | |
| 30 | Generic contact (from input 2) | 1 Bit | 1.1 switch | CRT | |
| 32 | Room temperature (from bus) | 2 Bytes | 9.1 temperature (°C) | CW | |
| 33 | Outdoor temperature (from bus) | 2 Bytes | 9.1 temperature (°C) | CW | |
| 34 | Coil battery temperature sensor from bus | 2 Bytes | 9.1 temperature (°C) | CW | |
| 35 | Antistratification temperature from bus | 2 Bytes | 9.1 temperature (°C) | CW | |
| 36 | Water supply temperature from bus | 2 Bytes | 9.1 temperature (°C) | CW | |
| 37 | Drip tray contact from bus | 1 Bit | 1.5 alarm | CW | |
| 38 | Window contact 1 (from bus) | 1 Bit | 1.19 window/door | CW | |
| 39 | Window contact 2 (from bus) | 1 Bit | 1.19 window/door | CW | |
| 40 | Presence sensor 1 from bus | 1 Bit | 1.18 occupancy | CW | |
| 41 | Presence sensor 2 from bus | 1 Bit | 1.18 occupancy | CW | |
| 42 | Heating/cooling status out | 1 Bit | 1.100 heating/cooling | CRT | |
| 43 | Heating/cooling changeover command | 1 Bit | 1.100 heating/cooling | CW | |
| 44 | HVAC mode IN | 1 Byte | 20.102 HVAC mode | CW | |
| 45 | HVAC manual mode | 1 Byte | 20.102 HVAC mode | CW | |
| 46 | HVAC chrono mode active status | 1 Bit | 1.11 state | CRWTU | |
| 47 | HVAC mode OUT | 1 Byte | 20.102 HVAC mode | CRT | |
| 48 | Actual setpoint | 2 Bytes | 9.1 temperature (°C) | CRT | |
| 49 | Input setpoint | 2 Bytes | 9.1 temperature (°C) | CW | |
| 50 | Comfort setpoint (heating) | 2 Bytes | 9.1 temperature (°C) | CRWTU | |
| 51 | Comfort setpoint (cooling) | 2 Bytes | 9.1 temperature (°C) | CRWTU | |
| 52 | Standby offset (heating) | 2 Bytes | 9.2 temperature difference (K) | CRWTU | |
| 52 | Standby setpoint (heating) | 2 Bytes | 9.1 temperature (°C) | CRWTU | |
| 53 | Standby offset (cooling) | 2 Bytes | 9.2 temperature difference (K) | CRWTU | |
| 53 | Standby setpoint (cooling) | 2 Bytes | 9.1 temperature (°C) | CRWTU | |
| 54 | Economy offset (heating) | 2 Bytes | 9.2 temperature difference (K) | CRWTU | |
| 54 | Economy setpoint (heating) | 2 Bytes | 9.1 temperature (°C) | CRWTU | |
| 55 | Economy offset (cooling) | 2 Bytes | 9.2 temperature difference (K) | CRWTU | |
| 55 | Economy setpoint (cooling) | 2 Bytes | 9.1 temperature (°C) | CRWTU | |
| 56 | Building protection (heating) | 2 Bytes | 9.1 temperature (°C) | CRWTU | |
| 57 | Building protection (cooling) | 2 Bytes | 9.1 temperature (°C) | CRWTU | |
| 58 | Manual/forced setpioint active status | 1 Bit | 1.11 state | CRWTU | |
| 59 | Manual setpoint | 2 Bytes | 9.1 temperature (°C) | CRWTU | |
| 60 | Cooling compensation offset | 2 Bytes | 9.2 temperature difference (K) | CRT | |
| 61 | Temperature controller output | 1 Byte | 5.1 percentage (0..100%) | CRT | |
| 62 | Fan working time (hours) | 2 Bytes | 7.7 time (h) | CRT | |
| 63 | Fan working time (seconds) | 4 Bytes | 13.100 time lag (s) | CRT | |
| 64 | Filter change warning | 1 Bit | 1.5 alarm | CRWT | |
| 65 | Fan disable from bus | 1 Bit | 1.3 enable | CW | |
| 66 | Fan manual / auto status | 1 Bit | 1.11 state | CRWTU | |
| 67 | Heating/cooling valve disable from bus | 1 Bit | 1.3 enable | CW | |
| 67 | Heating valve disable from bus | 1 Bit | 1.3 enable | CW | |
| 68 | Cooling valve disable from bus | 1 Bit | 1.3 enable | CW | |
| 71 | Controller output forced from bus | 1 Byte | 5.1 percentage (0..100%) | CW | |
| 72 | Controller output in automatic/forced from bus mode | 1 Bit | 1.3 enable | CW | |
| 73 | Drip tray status | 1 Bit | 1.5 alarm | CRT | |
| 75 | Power off alarm | 1 Bit | 1.5 alarm | CRT | |
| 76 | Output V1 from bus | 1 Bit | 1.1 switch | CW | |
| 77 | Output V2 from bus | 1 Bit | 1.1 switch | CW | |
| 78 | Output V3 from bus | 1 Bit | 1.1 switch | CW | |
| 79 | Output DO1 from bus | 1 Bit | 1.1 switch | CW | |
| 82 | Fan speed limit enable | 1 Bit | 1.3 enable | CW | |
| 83 | Alarm text | 14 Bytes | 16.0 Character String (ASCII) | CRT | |
| 84 | Logic function 1 - Input 1 | 1 Bit | 1.1 switch | CWTU | |
| 85 | Logic function 1 - Input 2 | 1 Bit | 1.1 switch | CWTU | |
| 86 | Logic function 1 - Input 3 | 1 Bit | 1.1 switch | CWTU | |
| 87 | Logic function 1 - Input 4 | 1 Bit | 1.1 switch | CWTU | |
| 88 | Logic function 1 - Output | 1 Bit | 1.1 switch | CRT | |
| 89 | Logic function 2 - Input 1 | 1 Bit | 1.1 switch | CWTU | |
| 90 | Logic function 2 - Input 2 | 1 Bit | 1.1 switch | CWTU | |
| 91 | Logic function 2 - Input 3 | 1 Bit | 1.1 switch | CWTU | |
| 92 | Logic function 2 - Input 4 | 1 Bit | 1.1 switch | CWTU | |
| 93 | Logic function 2 - Output | 1 Bit | 1.1 switch | CRT | |
| 94 | Logic function 3 - Input 1 | 1 Bit | 1.1 switch | CWTU | |
| 95 | Logic function 3 - Input 2 | 1 Bit | 1.1 switch | CWTU | |
| 96 | Logic function 3 - Input 3 | 1 Bit | 1.1 switch | CWTU | |
| 97 | Logic function 3 - Input 4 | 1 Bit | 1.1 switch | CWTU | |
| 98 | Logic function 3 - Output | 1 Bit | 1.1 switch | CRT | |
| 99 | Logic function 4 - Input 1 | 1 Bit | 1.1 switch | CWTU | |
| 100 | Logic function 4 - Input 2 | 1 Bit | 1.1 switch | CWTU | |
| 101 | Logic function 4 - Input 3 | 1 Bit | 1.1 switch | CWTU | |
| 102 | Logic function 4 - Input 4 | 1 Bit | 1.1 switch | CWTU | |
| 103 | Logic function 4 - Output | 1 Bit | 1.1 switch | CRT | |
| 104 | Logic function 5 - Input 1 | 1 Bit | 1.1 switch | CWTU | |
| 105 | Logic function 5 - Input 2 | 1 Bit | 1.1 switch | CWTU | |
| 106 | Logic function 5 - Input 3 | 1 Bit | 1.1 switch | CWTU | |
| 107 | Logic function 5 - Input 4 | 1 Bit | 1.1 switch | CWTU | |
| 108 | Logic function 5 - Output | 1 Bit | 1.1 switch | CRT | |
| 109 | Logic function 6 - Input 1 | 1 Bit | 1.1 switch | CWTU | |
| 110 | Logic function 6 - Input 2 | 1 Bit | 1.1 switch | CWTU | |
| 111 | Logic function 6 - Input 3 | 1 Bit | 1.1 switch | CWTU | |
| 112 | Logic function 6 - Input 4 | 1 Bit | 1.1 switch | CWTU | |
| 113 | Logic function 6 - Output | 1 Bit | 1.1 switch | CRT | |
| 114 | Logic function 7 - Input 1 | 1 Bit | 1.1 switch | CWTU | |
| 115 | Logic function 7 - Input 2 | 1 Bit | 1.1 switch | CWTU | |
| 116 | Logic function 7 - Input 3 | 1 Bit | 1.1 switch | CWTU | |
| 117 | Logic function 7 - Input 4 | 1 Bit | 1.1 switch | CWTU | |
| 118 | Logic function 7 - Output | 1 Bit | 1.1 switch | CRT | |
| 119 | Logic function 8 - Input 1 | 1 Bit | 1.1 switch | CWTU | |
| 120 | Logic function 8 - Input 2 | 1 Bit | 1.1 switch | CWTU | |
| 121 | Logic function 8 - Input 3 | 1 Bit | 1.1 switch | CWTU | |
| 122 | Logic function 8 - Input 4 | 1 Bit | 1.1 switch | CWTU | |
| 123 | Logic function 8 - Output | 1 Bit | 1.1 switch | CRT |
Parameters (133)
| Parameter | Type | Default |
|---|---|---|
| Delay after bus voltage recovery | time | 400 |
| Contact type | list | NO (normally open) |
| Debounce time | time | 20 |
| Minimum change of value to send [K] | float 0…5 | 0.5 |
| Cyclic sending interval | list | no sending |
| Threshold 1 | list | not active |
| Threshold 2 | list | not active |
| Value [°C] | float -25…60 | 7 |
| Value [°C] | float -25…60 | 45 |
| Hysteresis | list | 0.4 K |
| Digital sensors timeout | time | 300 |
| Room temperature | list | disabled |
| Antistratification temperature | list | disabled |
| Outdoor temperature | list | disabled |
| Coil temperature | list | disabled |
| Flow temperature | list | disabled |
| Window contact 1 | list | disabled |
| Window contact 2 | list | disabled |
| Presence sensor 1 | list | disabled |
| Presence sensor 2 | list | disabled |
| Filter type | list | medium |
| Signal | list | not inverted |
| Application | list | fan-coil |
| Function | list | heating |
| Installation type | list | 2 pipes |
| Controller | list | external |
| Power status feedback | list | disabled |
| Report filter change | list | no |
| Ventilation Object format | list | percentage [DPT 5.001] |
| Input 1 | list | disabled |
| Offset | list | 0.0 °C |
| Input 2 | list | disabled |
| Communication Object timeout | time | 300 |
| Analog sensors timeout | time | 300 |
| Inputs | list | different |
| Drip tray level | list | disabled |
| First speed threshold [%] | unsignedInt 0…100 | 10 |
| Control type | list | 1 speed (relais) |
| Cold start | list | no |
| Warm start | list | no |
| Second speed threshold [%] | unsignedInt 0…100 | 40 |
| Third speed threshold [%] | unsignedInt 0…100 | 70 |
| Hysteresis [%] | unsignedInt 0…100 | 5 |
| Coil temperature | unsignedInt 28…40 | 35 |
| Coil temperature | unsignedInt 7…18 | 12 |
| Antistratification | list | disabled |
| Disable from bus | list | disabled |
| Temperature differential | list | 2.00 K/m |
| Hysteresis | list | 0.6 K |
| Start delay | list | 0 s |
| Stop delay | list | 0 s |
| Control feedback | list | no |
| Control type | list | on/off |
| Control can be disabled from bus | list | no |
| Valve position feedback | list | disabled |
| Valve position after timeout | list | off |
| PWM cycle time | time | 15 |
| Min. control value [%] | unsignedInt 0…30 | 15 |
| Max. control value [%] | unsignedInt 70…100 | 85 |
| Antiscuff protection | list | disabled |
| Frequency | list | once a week |
| Time interval | list | 10 s |
| Auxiliary output type | list | not active |
| Setpoint type | list | relative |
| Heating/cooling changeover | list | from bus |
| Temperature for changeover (heating) | float 20…50 | 35 |
| Temperature for changeover (cooling) | float 5…20 | 16 |
| Changeover cyclic sending interval | list | no sending |
| Comfort setpoint [°C] | float 10…50 | 21 |
| Standby offset [0.1 K] | signedInt -50…-10 | -30 |
| Economy offset [0.1 K] | signedInt -89…-10 | -50 |
| Building protection [°C] | float 2…10 | 7 |
| Proportional band [0.1 K] | unsignedInt 0…255 | 30 |
| Integral time [min] | unsignedInt 0…255 | 0 |
| Min change of value to send [%] | unsignedInt 0…100 | 10 |
| Forced mode | list | no |
| Comfort setpoint [°C] | float 10…50 | 23 |
| Standby offset [0.1 K] | signedInt 10…50 | 30 |
| Economy offset [0.1 K] | signedInt 10…80 | 50 |
| Building protection [°C] | float 20…50 | 36 |
| Summer compensation | list | disabled |
| Lowest external temperature [°C] | unsignedInt 25…40 | 25 |
| Coefficient | list | 1 K each 4 K external temp. change |
| Min change to send value | list | 0.6 K |
| Window contacts function | list | disabled |
| Time to wait before HVAC change | time | 60 |
| Presence sensors function | list | disabled |
| Use | list | comfort extension |
| Modes | list | comfort - standby |
| In case of drip | list | close valve and switch fan off |
| Drip control | list | disabled |
| Change filter warning after [weeks] | unsignedInt 1…128 | 16 |
| Send warning | list | on filter change only |
| Send usage time | list | no sending (only reading) |
| Cyclic sending interval | list | 24 h |
| Speed at timeout | list | speed 1 |
| Communication Object | list | separated |
| Valve Object format | list | output status [DPT 1.001] |
| First speed threshold [0.1K] | unsignedInt 0…255 | 0 |
| Second speed threshold [0.1K] | unsignedInt 0…255 | 10 |
| Third speed threshold [0.1K] | unsignedInt 0…255 | 20 |
| Hysteresis [0.1K] | list | 0.3 K |
| Temperature setpoint [°C] | float 10…50 | 21 |
| Temperature setpoint [°C] | float 10…50 | 23 |
| Fan speed limit from bus | list | not limited |
| Setpoint CO type | list | absolute |
| RoomTemp | list | no |
| Communication Object type | list | seconds [DPT 13.100] |
| Time-scheduled antistratification | list | disabled |
| Frequency | list | 30 min |
| Time interval | list | 2 min |
| Fan control | list | depending on temperature |
| Logic functions | list | disabled |
| Logic function | list | disabled |
| Logic operation | list | OR |
| Output cyclic sending interval | list | no sending |
| Logic object 1 | list | disabled |
| Logic object 2 | list | disabled |
| Logic object 3 | list | disabled |
| Logic object 4 | list | disabled |
| Logic object 1 negated | list | no |
| Logic object 2 negated | list | no |
| Logic object 3 negated | list | no |
| Logic object 4 negated | list | no |
| Logic object 1 read at startup | list | no |
| Logic object 2 read at startup | list | no |
| Logic object 3 read at startup | list | no |
| Logic object 4 read at startup | list | no |
| Logic object 1 default value | list | none |
| Logic object 2 default value | list | none |
| Logic object 3 default value | list | none |
| Logic object 4 default value | list | none |
| End of manual operation | list | till first telegram from bus |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| APEKHA1TP 0.3 latest | $4841 | FFA0 | 2026-11-25 | 127 KB | Download |
| APEKHA1TP 0.2 | $4841 | D8D2 | 2026-11-25 | 104 KB | Download |
| APEKHA1TP 0.1 | $4841 | D5A2 | 2026-11-25 | 82 KB | Download |
About this file
This is the official ETS product database for the Ekinex S.p.A. Fan-coil actuator/controller (EK-HA1-TP), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from Ekinex S.p.A.
- Universal interface 4 DI + 4 DI / NTC EK-CA1-TP
- Universal interface 4 DI / 2 relais 5A EK-CE2-TP
- Universal interface 4 DI / NTC EK-CG2-TP
- Room temperature controller 71 Serie EK-E72-TP
- Room temperature controller 71 Serie - EASY EK-E73-EASY
- Room temperature controller 71 Serie EK-E73-TP
- Touch & See with integrated pushbutton 2 channels EK-EF2-TP
- Easy room temperature controller with LCD EK-EM2-TP-E
- Full room temperature controller with LCD EK-EM2-TP-F
- Room temperature controller with LCD EK-EP2-TP
- Room temperature controller with LCD and relative humidity sensor EK-EQ2-TP
- Easy room temperature Easy controller with LCD EK-ER2-TP