KNX Database
Ekinex S.p.A. EK-ET3-TP Multisensor T, RH and CO2eq with controller

Multisensor T, RH and CO2eq with controller EK-ET3-TP

Ekinex S.p.A. · Order number EK-ET3-TP · Heating, cooling and ventilation

Multisensor T, RH and CO2eq with controller

Download .knxprod APEKET3TP 0.3 · 164 KB

Product

ManufacturerEkinex S.p.A.
Product nameMultisensor T, RH and CO2eq with controller
Order numberEK-ET3-TP
HardwareMultisensor T, RH and CO2eq with controller
MediumTwisted Pair
Bus current (mA)14
Rail mountedNo
RegistrationCertified · 2022-06-07
Languagesen-US, de-DE, fr-FR, it-IT
Catalog entryM-00B6_H-00B600000031-2_HP-4554-03-73F2_CI-EK.2DET3.2DTP-1
Fingerprint73F2
SHA-256ffa1266d1e4f86cd696bfe822967daeec17ee5b9751d26e3cfc7c07e75b22965
First seen2026-11-25
Markets69 markets

Application program: APEKET3TP 0.3

Application number$4554
Version0.3
Mask versionMV-0705 (7.5)
KNX Data SecureNo
Minimum ETS version4.0
Parameters532
Group objects156
Group objects (156)
NoNameFunctionSizeDPTFlags
0Technical alarm1 Bit1.5 alarmCW
1Leds intensity percentage1 Byte5.1 percentage (0..100%)CW
2Temperature value2 Bytes9.1 temperature (°C)CRT
3Temperature threshold 1 - Switch1 Bit1.1 switchCRT
4Temperature threshold 1 - Lock1 Bit1.1 switchCW
5Temperature threshold 1 - Value (from bus)2 Bytes9.1 temperature (°C)CW
6Temperature threshold 2 - Switch1 Bit1.1 switchCRT
7Temperature threshold 2 - Lock1 Bit1.1 switchCW
8Temperature threshold 2 - Value (from bus)2 Bytes9.1 temperature (°C)CW
9CO2 - Value2 Bytes9.8 parts/million (ppm)CRT
10Humidity value (2 bytes)2 Bytes9.7 humidity (%)CRT
11Humidity value (1 byte)1 Byte5.1 percentage (0..100%)CRT
12Humidity threshold 1 - Switch1 Bit1.1 switchCRT
13Humidity threshold 1 - Lock1 Bit1.3 enableCW
14Humidity threshold 1 - Value (2 bytes, from bus)2 Bytes9.7 humidity (%)CW
15Humidity threshold 1 - Value (1 byte, from bus)1 Byte5.1 percentage (0..100%)CW
16Humidity threshold 2 - Switch1 Bit1.1 switchCRT
17Humidity threshold 2 - Lock1 Bit1.3 enableCW
18Humidity threshold 2 - Value (2 bytes, from bus)2 Bytes9.7 humidity (%)CW
19Humidity threshold 2 - Value (1 bytes, from bus)1 Byte5.1 percentage (0..100%)CW
20Thermostat - Room temperature (from bus)2 Bytes9.1 temperature (°C)CWTU
21Thermostat - Humidity (2 bytes, from bus)2 Bytes9.7 humidity (%)CWTU
22Thermostat - Humidity (1 byte, from bus)1 Byte5.1 percentage (0..100%)CWTU
23Thermostat - Antistratification temperature (from bus)2 Bytes9.1 temperature (°C)CWTU
24Thermostat - Outdoor temperature (from bus)2 Bytes9.1 temperature (°C)CWTU
25Thermostat - Coil temperature (from bus)2 Bytes9.1 temperature (°C)CWTU
26Thermostat - Floor temperature (from bus)2 Bytes9.1 temperature (°C)CWTU
27Thermostat - Flow temperature (from bus)2 Bytes9.1 temperature (°C)CWTU
28Thermostat - Windows contact sensor 1 (from bus)1 Bit1.19 window/doorCWTU
29Thermostat - Windows contact sensor 2 (from bus)1 Bit1.19 window/doorCWTU
30Thermostat - Presence sensor 1 (from bus)1 Bit1.18 occupancyCWTU
31Thermostat - Presence sensor 2 (from bus)1 Bit1.18 occupancyCWTU
32Thermostat - Contact of card holder (from bus)1 Bit1.18 occupancyCWTU
33Thermostat - Anticondensation (from bus)1 Bit1.1 switchCWTU
34Thermostat - Weighted temperature2 Bytes9.1 temperature (°C)CRT
35Thermostat - Heating/cooling status out1 Bit1.100 heating/coolingCRT
36Thermostat - Heating/cooling status in1 Bit1.100 heating/coolingCW
37Thermostat - HVAC mode in1 Byte20.102 HVAC modeCW
38Thermostat - HVAC forced mode in1 Byte20.102 HVAC modeCW
39Thermostat - HVAC mode out1 Byte20.102 HVAC modeCRT
40Thermostat - HVAC manual mode1 Byte20.102 HVAC modeCRWTU
41Thermostat - Building protection HVAC mode active1 Bit1.11 stateCRT
42Thermostat - Chrono active status1 Bit1.11 stateCRT
43Thermostat - Actual setpoint2 Bytes9.1 temperature (°C)CRT
44Thermostat - Manual setpoint2 Bytes9.1 temperature (°C)CW
45Thermostat - Manual setpoint status1 Bit1.11 stateCRWTU
46Thermostat - Comfort setpoint (heating)2 Bytes9.1 temperature (°C)CRWTU
46Thermostat - Setpoint in2 Bytes9.1 temperature (°C)CRWTU
47Thermostat - Comfort setpoint (cooling)2 Bytes9.1 temperature (°C)CRWTU
48Thermostat - Standby setpoint (heating)2 Bytes9.1 temperature (°C)CRWTU
48Thermostat - Offset standby (heating)2 Bytes9.2 temperature difference (K)CRWTU
49Thermostat - Standby setpoint (cooling)2 Bytes9.1 temperature (°C)CRWTU
49Thermostat - Offset standby (cooling)2 Bytes9.2 temperature difference (K)CRWTU
50Thermostat - Economy setpoint (heating)2 Bytes9.1 temperature (°C)CRWTU
50Thermostat - Offset economy (heating)2 Bytes9.2 temperature difference (K)CRWTU
51Thermostat - Economy setpoint (cooling)2 Bytes9.1 temperature (°C)CRWTU
51Thermostat - Offset economy (cooling)2 Bytes9.2 temperature difference (K)CRWTU
52Thermostat - Building protection setpoint (heating)2 Bytes9.1 temperature (°C)CRWTU
53Thermostat - Building protection setpoint (cooling)2 Bytes9.1 temperature (°C)CRWTU
54Thermostat - Disable room temperature controller1 Bit1.1 switchCW
55Thermostat - Room temperature controller status1 Bit1.3 enableCRT
56Thermostat - Heating out command1 Byte5.1 percentage (0..100%)CRT
56Thermostat - Heating out command1 Bit1.1 switchCRT
56Thermostat - Heating and cooling out command1 Bit1.1 switchCRT
56Thermostat - Heating and cooling out command1 Byte5.1 percentage (0..100%)CRT
57Thermostat - Cooling out command1 Byte5.1 percentage (0..100%)CRT
57Thermostat - Cooling out command1 Bit1.1 switchCRT
58Thermostat - Auxiliary heating output command1 Bit1.1 switchCRT
58Thermostat - Auxiliary heating and cooling output command1 Bit1.1 switchCRT
59Thermostat - Auxiliary cooling output command1 Bit1.1 switchCRT
60Thermostat - Auxiliary heating disable1 Bit1.3 enableCW
61Thermostat - Auxiliary cooling disable1 Bit1.3 enableCW
62Thermostat - Fan continuous speed1 Byte5.1 percentage (0..100%)CRT
63Thermostat - Fan speed 11 Bit1.1 switchCRT
64Thermostat - Fan speed 21 Bit1.1 switchCRT
65Thermostat - Fan speed 31 Bit1.1 switchCRT
66Thermostat - Fan control disable1 Bit1.2 booleanCW
67Thermostat - Fan speed1 Byte5.10 counter pulses (0..255)CRT
68Thermostat - Fan manual speed1 Byte5.10 counter pulses (0..255)CRWU
69Thermostat - Fan manual speed percentage1 Byte5.1 percentage (0..100%)CRT
70Thermostat - Fan manual active status1 Bit1.11 stateCRWT
71Thermostat - Fan manual speed off status1 Bit1.11 stateCRT
72Thermostat - Room temperature controller alarm1 Bit1.5 alarmCRT
73Thermostat - Dew-point temperature2 Bytes9.1 temperature (°C)CRT
74Thermostat - Relative humidity setpoint for dehumidification2 Bytes9.7 humidity (%)CRWTU
75Thermostat - Relative humidity setpoint for humidification2 Bytes9.7 humidity (%)CRWTU
76Thermostat - Dehumidification command1 Bit1.1 switchCRT
77Thermostat - Dehumidification water battery command1 Bit1.1 switchCRT
78Thermostat - Dehumidification integration control1 Bit1.1 switchCRT
79Thermostat - Dehumidification control disable1 Bit1.2 booleanCW
80Thermostat - Humidification command1 Bit1.1 switchCRT
81Thermostat - Humidification control disable1 Bit1.2 booleanCW
82Thermostat - Anticondensation alarm1 Bit1.5 alarmCRT
83Thermostat - Thermal generator lock1 Bit1.5 alarmCW
84Thermostat - HVAC scene number1 Byte17.1 scene numberCW
85Thermostat - Alarm text14 Bytes16.0 Character String (ASCII)CRT
86CO2 threshold 1 - Percentage1 Byte5.1 percentage (0..100%)CRT
86CO2 threshold 1 - Counter1 Byte5.10 counter pulses (0..255)CRT
86CO2 threshold 1 - Switch1 Bit1.1 switchCRT
87CO2 threshold 1 - Lock1 Bit1.3 enableCW
88CO2 threshold 2 - Switch1 Bit1.1 switchCRT
88CO2 threshold 2 - Counter1 Byte5.10 counter pulses (0..255)CRT
88CO2 threshold 2 - Percentage1 Byte5.1 percentage (0..100%)CRT
89CO2 threshold 2 - Lock1 Bit1.3 enableCW
90CO2 threshold 3 - Switch1 Bit1.1 switchCRT
90CO2 threshold 3 - Counter1 Byte5.10 counter pulses (0..255)CRT
90CO2 threshold 3 - Percentage1 Byte5.1 percentage (0..100%)CRT
91CO2 threshold 3 - Lock1 Bit1.3 enableCW
92CO2 ventilation bit 1 - switch1 Bit1.1 switchCRT
92CO2 ventilation - Counter1 Byte5.10 counter pulses (0..255)CRT
92CO2 ventilation - Percentage1 Byte5.1 percentage (0..100%)CRT
93CO2 ventilation bit 2 - switch1 Bit1.1 switchCRT
94CO2 ventilation bit 3 - switch1 Bit1.1 switchCRT
95CO2 ventilation bit 4 - switch1 Bit1.1 switchCRT
96CO2 ventilation - lock1 Bit1.3 enableCW
97CO2 ventilation - Disable1 Bit1.3 enableCW
98Logic function 1 - Input 11 Bit1.1 switchCWTU
99Logic function 1 - Input 21 Bit1.1 switchCWTU
100Logic function 1 - Input 31 Bit1.1 switchCWTU
101Logic function 1 - Input 41 Bit1.1 switchCWTU
102Logic function 1 - Output1 Bit1.1 switchCRT
103Logic function 2 - Input 11 Bit1.1 switchCWTU
104Logic function 2 - Input 21 Bit1.1 switchCWTU
105Logic function 2 - Input 31 Bit1.1 switchCWTU
106Logic function 2 - Input 41 Bit1.1 switchCWTU
107Logic function 2 - Output1 Bit1.1 switchCRT
108Logic function 3 - Input 11 Bit1.1 switchCWTU
109Logic function 3 - Input 21 Bit1.1 switchCWTU
110Logic function 3 - Input 31 Bit1.1 switchCWTU
111Logic function 3 - Input 41 Bit1.1 switchCWTU
112Logic function 3 - Output1 Bit1.1 switchCRT
113Logic function 4 - Input 11 Bit1.1 switchCWTU
114Logic function 4 - Input 21 Bit1.1 switchCWTU
115Logic function 4 - Input 31 Bit1.1 switchCWTU
116Logic function 4 - Input 41 Bit1.1 switchCWTU
117Logic function 4 - Output1 Bit1.1 switchCRT
118Logic function 5 - Input 11 Bit1.1 switchCWTU
119Logic function 5 - Input 21 Bit1.1 switchCWTU
120Logic function 5 - Input 31 Bit1.1 switchCWTU
121Logic function 5 - Input 41 Bit1.1 switchCWTU
122Logic function 5 - Output1 Bit1.1 switchCRT
123Logic function 6 - Input 11 Bit1.1 switchCWTU
124Logic function 6 - Input 21 Bit1.1 switchCWTU
125Logic function 6 - Input 31 Bit1.1 switchCWTU
126Logic function 6 - Input 41 Bit1.1 switchCWTU
127Logic function 6 - Output1 Bit1.1 switchCRT
128Logic function 7 - Input 11 Bit1.1 switchCWTU
129Logic function 7 - Input 21 Bit1.1 switchCWTU
130Logic function 7 - Input 31 Bit1.1 switchCWTU
131Logic function 7 - Input 41 Bit1.1 switchCWTU
132Logic function 7 - Output1 Bit1.1 switchCRT
133Logic function 8 - Input 11 Bit1.1 switchCWTU
134Logic function 8 - Input 21 Bit1.1 switchCWTU
135Logic function 8 - Input 31 Bit1.1 switchCWTU
136Logic function 8 - Input 41 Bit1.1 switchCWTU
137Logic function 8 - Output1 Bit1.1 switchCRT
Parameters (218)
ParameterTypeDefault
CO2 sensorlistenabled
Temperature sensorlistenabled
Input 1listdisabled
Minimum change of value to send [ppm]unsignedInt 0…1000050
Cyclic sending intervallistno sending
Minimum change of value to send [K]float 0…50.5
Delay after bus voltage recoverytime400
Leds intensity from buslistno
Leds intensitylist50%
Led L1 and L2 (temperature control)listenabled
Led L3 and L4 (humidity control)listenabled
Led L5, L6, L7 and L8 (CO2 control)listenabled
Temperature offsetlist0.0 °C
Technical alarmlistdisabled
Input 2listdisabled
Relative humidity sensorlistdisabled
Threshold 2listnot active
Threshold 1listnot active
Value [°C]float 0…5045
Value [°C]float 0…507
Hysteresislist0.4 K
Value [%]unsignedInt 0…10065
Hysteresis [%]list3.0 %
Minimum change of value to send [%]unsignedInt 0…102
Digital sensors timeouttime300
Room temperaturelistdisabled
Relative humiditylistdisabled
Antistratification temperaturelistdisabled
Outdoor temperaturelistdisabled
Coil temperaturelistdisabled
Floor surface temperaturelistdisabled
Flow temperaturelistdisabled
Window contact 1listdisabled
Window contact 2listdisabled
Presence sensor 1listdisabled
Presence sensor 2listdisabled
Card holder contactlistdisabled
Humidity CO dimensionlist2 bytes
Relative weightlist50% / 50%
Filter typelistmedium
Anticondensationlistdisabled
Setpoint cyclic sending intervallistno sending
Sceneslistdisabled
Comfort temp. setpoint [°C]float 10…5021
Standby temperature setpoint [°C]float 10…5018
Economy temp. setpoint [°C]float 10…5016
Building protection temp. setpoint [°C]float 2…107
Control typelist2 points hysteresis
Command Communication Objectlistseparated
Hysteresislist0.3 K
PWM cycle timetime15
Proportional band [0.1K]unsignedInt 5…10040
Integral time [min]unsignedInt 0…25590
Valve protection functionlistdisabled
Frequencylistonce a week
Time intervallist10 s
Floor temperature limitationlistdisabled
Temperature limit [°C]float 20…4029
Auxiliary heatinglistdisabled
Communication objectlistseparated
Offset from setpointlist0.6 K
Disabled from buslistno
Ventilation for auxiliary heatinglistdisabled
Comfort temp. setpoint [°C]float 10…5023
Standby temperature setpoint [°C]float 10…5026
Economy temp. setpoint [°C]float 10…5028
Building protection temp. setpoint [°C]float 30…5036
Cooling typelistfancoils
Auxiliary coolinglistdisabled
Anticondensation with probelistdisabled
Active anticondensationlistdisabled
Min. change of value to send [%]unsignedInt 0…10010
Anticondensation hysteresis rangelist0.5 K
Control typelist3 speeds
Threshold first speed [0.1K]unsignedInt 0…2550
Threshold second speed [0.1K]unsignedInt 0…25510
Threshold third speed [0.1K]unsignedInt 0…25520
Manual operationlistnot depending on the temperature
Hot startlistno
Speed control hysteresislist0.3 K
Speed proportional band [0.1K]unsignedInt 5…10030
Min. change of value to send [%]unsignedInt 2…4010
Min. temp. to start ventilation [°C]unsignedInt 28…4028
Antistratification functionlistdisabled
Antistratification temp. differentiallist2.00 [K/m]
Hysteresislist0.5 K
Disable ventilation from buslistno
Signal from buslistnot inverted
Fan start delaylist0 s
Fan stop delaylist0 s
Download overwritelistdisabled
Scene 1listdisabled
Scene 2listdisabled
Scene 3listdisabled
Scene 4listdisabled
Scene 5listdisabled
Scene 6listdisabled
Scene 7listdisabled
Scene 8listdisabled
Learning modelistdisabled
HVAC modelistcomfort
Scene numberunsignedInt 1…641
Activation delaytime0
Dew-point temperaturelistdisabled
Min. change of value to send [K]list0.2 K
Windows contacts functionlistdisabled
Presence sensors functionlistdisabled
Presence sensors uselistcomfort extension
Thermostat modeslistcomfort - standby
Wait time to building protection modetime60
Absence time to switch HVAC modetime60
Signallistnot inverted
Card holder functionlistdisabled
On card insertion switch HVAC mode tolistcomfort
On card removal switch HVAC mode toliststandby
Activation delay on card insertiontime0
Activation delay on card removaltime0
Ventilation for auxiliary coolinglistdisabled
Heating typelistradiators
Heating typelistfancoils
End of manual operationlisttill first telegram from bus
Humidity hysteresislist0.8 %
Subordinated to temperature controllistyes
Humidity setpointunsignedInt 20…8055
Integrationlistno
Dehumidification start delaytime300
Temperature difference for integrationlist1.5 °C
Hysteresis for integrationlist0.5 K
Disable dehumid. control from buslistno
Humidity setpointunsignedInt 20…8035
Disable humidification control from buslistno
Analog sensors timeouttime300
Flow temperature (project)list14 °C
Min control value [%]unsignedInt 0…3015
Max control value [%]unsignedInt 70…10085
Transmission delay after mode changetime400
Hysteresis positionlistbelow
Hysteresis positionlistabove
Delay for alarm signallist5 min
Heating - cooling switch overlistfrom bus
Thermostat functionlistheating
Heating - cooling cyclic sending intervallistno sending
Dehumidification functionlistdisabled
Humidification functionlistdisabled
Logic functionlistdisabled
Logic operationlistOR
Output cyclic sending intervallistno sending
Logic object 1listdisabled
Logic object 2listdisabled
Logic object 3listdisabled
Logic object 4listdisabled
Logic object 1 negatedlistno
Logic object 2 negatedlistno
Logic object 3 negatedlistno
Logic object 4 negatedlistno
Logic object 1 read at startuplistno
Logic object 2 read at startuplistno
Logic object 3 read at startuplistno
Logic object 4 read at startuplistno
Logic object 1 default valuelistnone
Logic object 2 default valuelistnone
Logic object 3 default valuelistnone
Logic object 4 default valuelistnone
Logic functionslistdisabled
Output sendinglistboth values
Output updatelistat value change
Setpoint typelistsingle
Disable temperature controller from buslistno
Cyclic reading eachlistno reading
Threshold value update from buslistno
Threshold lock enablelistno
Behaviour at locklistnone
Behaviour at bus recoverylistprevious state
Behaviour at bus recoverylistunlock
CO2 functionlistenabled
Value [ppm]unsignedInt 0…10000500
Hysteresislist250 ppm
Typelistnot active
Communication object dimensionlist1 bit value
Value (above)liston
Value (above)unsignedInt 0…2550
Percentage (above)unsignedInt 0…1000
Value (below)liston
Percentage (below)unsignedInt 0…1000
Value (below)unsignedInt 0…2550
Lock enablelistno
Valuelistoff
ValueunsignedInt 0…2550
PercentageunsignedInt 0…1000
CO2 ventilationlistdisabled
Communication object dimensionlist1 byte percentage
CO2 value < threshold 1unsignedInt 0…1000
CO2 value < threshold 1unsignedInt 0…2550
Bit 1listoff
Bit 2listoff
Bit 3listoff
Bit 4listoff
Threshold 1 < CO2 value < threshold 2unsignedInt 0…1000
Threshold 1 < CO2 value < threshold 2unsignedInt 0…2550
Threshold 2 < CO2 value < threshold 3unsignedInt 0…1000
Threshold 2 < CO2 value < threshold 3unsignedInt 0…2550
CO2 value > Threshold 3unsignedInt 0…1000
CO2 value > Threshold 3unsignedInt 0…2550
CO2 ventilation locklistdisabled
Behaviour after bus onlistprevious state
Lock valueunsignedInt 0…1000
Lock valueunsignedInt 0…2550
Value [ppm]unsignedInt 0…100001500
Value [ppm]unsignedInt 0…100005000
Temperature setpoint [°C]float 10…5021
Neutral zone [0.1 K]signedInt 10…8020
HVAC mode after downloadlistno change
Min. ventilation speed [%]unsignedInt 0…1000
Max. ventilation speed [%]unsignedInt 0…100100
Min. CO2 [ppm]unsignedInt 0…10000400
Max. CO2 [ppm]unsignedInt 0…100005000
CO2 offsetlist0 ppm
Humidity offsetlist0 %

Version history

ApplicationApp noFingerprintFirst seenSizeFile
APEKET3TP 0.3 latest$455473F22026-11-25164 KBDownload

About this file

This is the official ETS product database for the Ekinex S.p.A. Multisensor T, RH and CO2eq with controller (EK-ET3-TP), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Ekinex S.p.A.

All Ekinex S.p.A. products