Ekinex S.p.A. EK-ES3-TP Multisensor T, RH and CO2eq with controller

Multisensor T, RH and CO2eq with controller EK-ES3-TP

Ekinex S.p.A. · Order number EK-ES3-TP · Heating, cooling and ventilation

Multisensor T, RH and CO2eq with controller

Download .knxprod APEKES3TP 0.1 · 230 KB

Product

ManufacturerEkinex S.p.A.
Product nameMultisensor T, RH and CO2eq with controller
Order numberEK-ES3-TP
HardwareMultisensor T, RH and CO2eq with controller
MediumTwisted Pair
Bus current (mA)14
Rail mountedNo
RegistrationCertified · 2022-06-07
Languagesen-US, de-DE, fr-FR, it-IT
Catalog entryM-00B6_H-00B60000003C-2_HP-4553-01-4F1D_CI-EK.2DES3.2DTP-1
Fingerprint4F1D
SHA-25600d6f34921d59d1211dab18e51119a797976709ff22f9c7db076057e25b4b540
First seen2026-11-25
Markets69 markets

Application program: APEKES3TP 0.1

Application number$4553
Version0.1
Mask versionMV-0705 (7.5)
KNX Data SecureNo
Minimum ETS version5.0
Parameters617
Group objects174
Group objects (174)
NoNameFunctionSizeDPTFlags
0Technical alarm1 Bit1.5 alarmCW
1Leds intensity percentage1 Byte5.1 percentage (0..100%)CW
2Temperature value2 Bytes9.1 temperature (°C)CRT
3Temperature threshold 1 - Switch1 Bit1.1 switchCRT
4Temperature threshold 1 - Lock1 Bit1.1 switchCW
5Temperature threshold 1 - Value (from bus)2 Bytes9.1 temperature (°C)CW
6Temperature threshold 2 - Switch1 Bit1.1 switchCRT
7Temperature threshold 2 - Lock1 Bit1.1 switchCW
8Temperature threshold 2 - Value (from bus)2 Bytes9.1 temperature (°C)CW
9CO2 - Value2 Bytes9.8 parts/million (ppm)CRT
10Humidity value (2 bytes)2 Bytes9.7 humidity (%)CRT
11Humidity value (1 byte)1 Byte5.1 percentage (0..100%)CRT
12Humidity threshold 1 - Switch1 Bit1.1 switchCRT
13Humidity threshold 1 - Lock1 Bit1.3 enableCW
14Humidity threshold 1 - Value (2 bytes, from bus)2 Bytes9.7 humidity (%)CW
15Humidity threshold 1 - Value (1 byte, from bus)1 Byte5.1 percentage (0..100%)CW
16Humidity threshold 2 - Switch1 Bit1.1 switchCRT
17Humidity threshold 2 - Lock1 Bit1.3 enableCW
18Humidity threshold 2 - Value (2 bytes, from bus)2 Bytes9.7 humidity (%)CW
19Humidity threshold 2 - Value (1 bytes, from bus)1 Byte5.1 percentage (0..100%)CW
20Thermostat - Room temperature (from bus)2 Bytes9.1 temperature (°C)CWTU
21Thermostat - Humidity (2 bytes, from bus)2 Bytes9.7 humidity (%)CWTU
22Thermostat - Humidity (1 byte, from bus)1 Byte5.1 percentage (0..100%)CWTU
23Thermostat - Antistratification temperature (from bus)2 Bytes9.1 temperature (°C)CWTU
24Thermostat - Outdoor temperature (from bus)2 Bytes9.1 temperature (°C)CWTU
25Thermostat - Coil temperature (from bus)2 Bytes9.1 temperature (°C)CWTU
26Thermostat - Floor temperature (from bus)2 Bytes9.1 temperature (°C)CWTU
27Thermostat - Flow temperature (from bus)2 Bytes9.1 temperature (°C)CWTU
28Thermostat - Windows contact sensor 1 (from bus)1 Bit1.19 window/doorCWTU
29Thermostat - Windows contact sensor 2 (from bus)1 Bit1.19 window/doorCWTU
30Thermostat - Presence sensor 1 (from bus)1 Bit1.18 occupancyCWTU
31Thermostat - Presence sensor 2 (from bus)1 Bit1.18 occupancyCWTU
32Thermostat - Contact of card holder (from bus)1 Bit1.18 occupancyCWTU
33Thermostat - Anticondensation (from bus)1 Bit1.1 switchCWTU
34Thermostat - Weighted temperature2 Bytes9.1 temperature (°C)CRT
35Thermostat - Heating/cooling status out1 Bit1.100 cooling/heatingCRT
36Thermostat - Heating/cooling status in1 Bit1.100 cooling/heatingCW
37Thermostat - HVAC mode in1 Byte20.102 HVAC modeCW
38Thermostat - HVAC forced mode in1 Byte20.102 HVAC modeCW
39Thermostat - HVAC mode out1 Byte20.102 HVAC modeCRT
40Thermostat - HVAC manual mode1 Byte20.102 HVAC modeCRWTU
41Thermostat - Building protection HVAC mode active1 Bit1.11 stateCRT
42Thermostat - Chrono active status1 Bit1.11 stateCRT
43Thermostat - Actual setpoint2 Bytes9.1 temperature (°C)CRT
44Thermostat - Manual setpoint2 Bytes9.1 temperature (°C)CW
45Thermostat - Manual setpoint status1 Bit1.11 stateCRWTU
46Thermostat - Comfort setpoint (heating)2 Bytes9.1 temperature (°C)CRWTU
46Thermostat - Setpoint in2 Bytes9.1 temperature (°C)CRWTU
47Thermostat - Comfort setpoint (cooling)2 Bytes9.1 temperature (°C)CRWTU
48Thermostat - Standby setpoint (heating)2 Bytes9.1 temperature (°C)CRWTU
48Thermostat - Offset standby (heating)2 Bytes9.2 temperature difference (K)CRWTU
49Thermostat - Standby setpoint (cooling)2 Bytes9.1 temperature (°C)CRWTU
49Thermostat - Offset standby (cooling)2 Bytes9.2 temperature difference (K)CRWTU
50Thermostat - Economy setpoint (heating)2 Bytes9.1 temperature (°C)CRWTU
50Thermostat - Offset economy (heating)2 Bytes9.2 temperature difference (K)CRWTU
51Thermostat - Economy setpoint (cooling)2 Bytes9.1 temperature (°C)CRWTU
51Thermostat - Offset economy (cooling)2 Bytes9.2 temperature difference (K)CRWTU
52Thermostat - Building protection setpoint (heating)2 Bytes9.1 temperature (°C)CRWTU
53Thermostat - Building protection setpoint (cooling)2 Bytes9.1 temperature (°C)CRWTU
54Thermostat - Disable room temperature controller1 Bit1.1 switchCW
55Thermostat - Room temperature controller status1 Bit1.3 enableCRT
56Thermostat - Heating out command1 Byte5.1 percentage (0..100%)CRT
56Thermostat - Heating out command1 Bit1.1 switchCRT
56Thermostat - Heating and cooling out command1 Bit1.1 switchCRT
56Thermostat - Heating and cooling out command1 Byte5.1 percentage (0..100%)CRT
57Thermostat - Cooling out command1 Byte5.1 percentage (0..100%)CRT
57Thermostat - Cooling out command1 Bit1.1 switchCRT
58Thermostat - Auxiliary heating output command1 Bit1.1 switchCRT
58Thermostat - Auxiliary heating and cooling output command1 Bit1.1 switchCRT
59Thermostat - Auxiliary cooling output command1 Bit1.1 switchCRT
60Thermostat - Auxiliary heating disable1 Bit1.3 enableCW
61Thermostat - Auxiliary cooling disable1 Bit1.3 enableCW
62Thermostat - Fan continuous speed1 Byte5.1 percentage (0..100%)CRT
63Thermostat - Fan speed 11 Bit1.1 switchCRT
64Thermostat - Fan speed 21 Bit1.1 switchCRT
65Thermostat - Fan speed 31 Bit1.1 switchCRT
66Thermostat - Fan control disable1 Bit1.2 booleanCW
67Thermostat - Fan speed1 Byte5.100 fan stage (0..255)CRT
68Thermostat - Fan manual speed1 Byte5.100 fan stage (0..255)CRWU
69Thermostat - Fan manual speed percentage1 Byte5.1 percentage (0..100%)CRT
70Thermostat - Fan manual active status1 Bit1.11 stateCRWT
71Thermostat - Fan manual speed off status1 Bit1.11 stateCRT
72Thermostat - Room temperature controller alarm1 Bit1.5 alarmCRT
73Thermostat - Dew-point temperature2 Bytes9.1 temperature (°C)CRT
74Thermostat - Relative humidity setpoint for dehumidification2 Bytes9.7 humidity (%)CRWTU
75Thermostat - Relative humidity setpoint for humidification2 Bytes9.7 humidity (%)CRWTU
76Thermostat - Dehumidification command1 Bit1.1 switchCRT
77Thermostat - Dehumidification water battery command1 Bit1.1 switchCRT
78Thermostat - Dehumidification integration control1 Bit1.1 switchCRT
79Thermostat - Dehumidification control disable1 Bit1.2 booleanCW
80Thermostat - Humidification command1 Bit1.1 switchCRT
81Thermostat - Humidification control disable1 Bit1.2 booleanCW
82Thermostat - Anticondensation alarm1 Bit1.5 alarmCRT
83Thermostat - Thermal generator lock1 Bit1.5 alarmCW
84Thermostat - HVAC scene number1 Byte17.1 scene numberCW
85Thermostat - Alarm text14 Bytes16.0 Character String (ASCII)CRT
86CO2 threshold 1 - Percentage1 Byte5.1 percentage (0..100%)CRT
86CO2 threshold 1 - Counter1 Byte5.10 counter pulses (0..255)CRT
86CO2 threshold 1 - Switch1 Bit1.1 switchCRT
87CO2 threshold 1 - Lock1 Bit1.3 enableCW
88CO2 threshold 2 - Switch1 Bit1.1 switchCRT
88CO2 threshold 2 - Counter1 Byte5.10 counter pulses (0..255)CRT
88CO2 threshold 2 - Percentage1 Byte5.1 percentage (0..100%)CRT
89CO2 threshold 2 - Lock1 Bit1.3 enableCW
90CO2 threshold 3 - Switch1 Bit1.1 switchCRT
90CO2 threshold 3 - Counter1 Byte5.10 counter pulses (0..255)CRT
90CO2 threshold 3 - Percentage1 Byte5.1 percentage (0..100%)CRT
91CO2 threshold 3 - Lock1 Bit1.3 enableCW
92Ventilation bit 1 - switch1 Bit1.1 switchCRT
92Ventilation - Counter1 Byte5.10 counter pulses (0..255)CRT
92Ventilation - Percentage1 Byte5.1 percentage (0..100%)CRT
93Ventilation bit 2 - switch1 Bit1.1 switchCRT
94Ventilation bit 3 - switch1 Bit1.1 switchCRT
95Ventilation bit 4 - switch1 Bit1.1 switchCRT
96Ventilation - lock1 Bit1.3 enableCW
97Ventilation - Disable1 Bit1.3 enableCW
98Logic function 1 - Input 11 Bit1.1 switchCWTU
99Logic function 1 - Input 21 Bit1.1 switchCWTU
100Logic function 1 - Input 31 Bit1.1 switchCWTU
101Logic function 1 - Input 41 Bit1.1 switchCWTU
102Logic function 1 - Output1 Bit1.1 switchCRT
103Logic function 2 - Input 11 Bit1.1 switchCWTU
104Logic function 2 - Input 21 Bit1.1 switchCWTU
105Logic function 2 - Input 31 Bit1.1 switchCWTU
106Logic function 2 - Input 41 Bit1.1 switchCWTU
107Logic function 2 - Output1 Bit1.1 switchCRT
108Logic function 3 - Input 11 Bit1.1 switchCWTU
109Logic function 3 - Input 21 Bit1.1 switchCWTU
110Logic function 3 - Input 31 Bit1.1 switchCWTU
111Logic function 3 - Input 41 Bit1.1 switchCWTU
112Logic function 3 - Output1 Bit1.1 switchCRT
113Logic function 4 - Input 11 Bit1.1 switchCWTU
114Logic function 4 - Input 21 Bit1.1 switchCWTU
115Logic function 4 - Input 31 Bit1.1 switchCWTU
116Logic function 4 - Input 41 Bit1.1 switchCWTU
117Logic function 4 - Output1 Bit1.1 switchCRT
118Logic function 5 - Input 11 Bit1.1 switchCWTU
119Logic function 5 - Input 21 Bit1.1 switchCWTU
120Logic function 5 - Input 31 Bit1.1 switchCWTU
121Logic function 5 - Input 41 Bit1.1 switchCWTU
122Logic function 5 - Output1 Bit1.1 switchCRT
123Logic function 6 - Input 11 Bit1.1 switchCWTU
124Logic function 6 - Input 21 Bit1.1 switchCWTU
125Logic function 6 - Input 31 Bit1.1 switchCWTU
126Logic function 6 - Input 41 Bit1.1 switchCWTU
127Logic function 6 - Output1 Bit1.1 switchCRT
128Logic function 7 - Input 11 Bit1.1 switchCWTU
129Logic function 7 - Input 21 Bit1.1 switchCWTU
130Logic function 7 - Input 31 Bit1.1 switchCWTU
131Logic function 7 - Input 41 Bit1.1 switchCWTU
132Logic function 7 - Output1 Bit1.1 switchCRT
133Logic function 8 - Input 11 Bit1.1 switchCWTU
134Logic function 8 - Input 21 Bit1.1 switchCWTU
135Logic function 8 - Input 31 Bit1.1 switchCWTU
136Logic function 8 - Input 41 Bit1.1 switchCWTU
137Logic function 8 - Output1 Bit1.1 switchCRT
138TVOC - Value2 Bytes9.8 parts/million (ppm)CRT
139Thermostat - Indoor CO2 value (from bus)2 Bytes9.8 parts/million (ppm)CWTU
140Thermostat - Outdoor CO2 value (from bus)2 Bytes9.8 parts/million (ppm)CWTU
141Flow rate (from bus)2 Bytes9.20 voltage (mV)CWTU
142Insufficient flow rate alarm1 Bit1.5 alarmCRT
143TVOC threshold 1 - Switch1 Bit1.1 switchCRT
143TVOC threshold 1 - Counter1 Byte5.10 counter pulses (0..255)CRT
143TVOC threshold 1 - Percentage1 Byte5.1 percentage (0..100%)CRT
144TVOC threshold 1 - Lock1 Bit1.3 enableCW
145TVOC threshold 2 - Switch1 Bit1.1 switchCRT
145TVOC threshold 2 - Counter1 Byte5.10 counter pulses (0..255)CRT
145TVOC threshold 2 - Percentage1 Byte5.1 percentage (0..100%)CRT
146TVOC threshold 2 - Lock1 Bit1.3 enableCW
147TVOC threshold 3 - Switch1 Bit1.1 switchCRT
147TVOC threshold 3 - Counter1 Byte5.10 counter pulses (0..255)CRT
147TVOC threshold 3 - Percentage1 Byte5.1 percentage (0..100%)CRT
148TVOC threshold 3 - Lock1 Bit1.3 enableCW
149CO2 allarme superamento soglia1 Bit1.5 alarmCRT
Parameters (238)
ParameterTypeDefault
CO2 sensorlistenabled
Temperature sensorlistenabled
Input 1listdisabled
Minimum change of value to sendunsignedInt 0…1000050
Cyclic sending intervallistno sending
Minimum change of value to sendfloat 0…50.5
Delay after bus voltage recoverytime400
Leds intensity from buslistno
Leds intensitylist50%
Led L1 and L2 (temperature control)listenabled
Led L3 and L4 (humidity control)listenabled
Led L5 and L6 (CO2 control)listenabled
Temperature offsetlist0.0 °C
Technical alarmlistdisabled
Input 2listdisabled
Relative humidity sensorlistdisabled
Threshold 2listnot active
Threshold 1listnot active
Valuefloat 0…5045
Valuefloat 0…507
Hysteresislist0.4 K
ValueunsignedInt 0…10065
Hysteresislist3.0 %
Minimum change of value to sendunsignedInt 0…102
Digital sensors timeouttime300
Room temperaturelistdisabled
Relative humiditylistdisabled
Antistratification temperaturelistdisabled
Outdoor temperaturelistdisabled
Coil temperaturelistdisabled
Floor surface temperaturelistdisabled
Flow temperaturelistdisabled
Window contact 1listdisabled
Window contact 2listdisabled
Presence sensor 1listdisabled
Presence sensor 2listdisabled
Card holder contactlistdisabled
Humidity CO dimensionlist2 bytes
Relative weightlist50% / 50%
Filter typelistmedium
Anticondensationlistdisabled
Setpoint cyclic sending intervallistno sending
Sceneslistdisabled
Comfort temp. setpointfloat 10…5021
Standby temperature setpointfloat 10…5018
Economy temp. setpointfloat 10…5016
Building protection temp. setpointfloat 2…107
Control typelist2 points hysteresis
Command Communication Objectlistseparated
Hysteresislist0.3 K
PWM cycle timetime15
Proportional bandunsignedInt 5…10040
Integral timeunsignedInt 0…25590
Valve protection functionlistdisabled
Frequencylistonce a week
Time intervallist10 s
Floor temperature limitationlistdisabled
Temperature limitfloat 20…4029
Auxiliary heatinglistdisabled
Communication objectlistseparated
Offset from setpointlist0.6 K
Disabled from buslistno
Ventilation for auxiliary heatinglistdisabled
Comfort temp. setpointfloat 10…5023
Standby temperature setpointfloat 10…5026
Economy temp. setpointfloat 10…5028
Building protection temp. setpointfloat 30…5036
Cooling typelistfancoils
Auxiliary coolinglistdisabled
Anticondensation with probelistdisabled
Active anticondensationlistdisabled
Min. change of value to sendunsignedInt 0…10010
Anticondensation hysteresis rangelist0.5 K
Control typelist3 speeds
Threshold first speedunsignedInt 0…2550
Threshold second speedunsignedInt 0…25510
Threshold third speedunsignedInt 0…25520
Manual operationlistnot depending on the temperature
Hot startlistno
Speed control hysteresislist0.3 K
Speed proportional bandunsignedInt 5…10030
Min. change of value to sendunsignedInt 2…4010
Min. temp. to start ventilationunsignedInt 28…4028
Antistratification functionlistdisabled
Antistratification temp. differentiallist2.00 [K/m]
Hysteresislist0.5 K
Disable ventilation from buslistno
Signal from buslistnot inverted
Fan start delaylist0 s
Fan stop delaylist0 s
Download overwritelistdisabled
Scene 1listdisabled
Scene 2listdisabled
Scene 3listdisabled
Scene 4listdisabled
Scene 5listdisabled
Scene 6listdisabled
Scene 7listdisabled
Scene 8listdisabled
Learning modelistdisabled
HVAC modelistcomfort
Scene numberunsignedInt 1…641
Activation delaytime0
Dew-point temperaturelistdisabled
Min. change of value to sendlist0.2 K
Windows contacts functionlistdisabled
Presence sensors functionlistdisabled
Presence sensors uselistcomfort extension
Thermostat modeslistcomfort - standby
Wait time to building protection modetime60
Absence time to switch HVAC modetime60
Signallistnot inverted
Card holder functionlistdisabled
On card insertion switch HVAC mode tolistcomfort
On card removal switch HVAC mode toliststandby
Activation delay on card insertiontime0
Activation delay on card removaltime0
Ventilation for auxiliary coolinglistdisabled
Heating typelistradiators
Heating typelistfancoils
End of manual operationlisttill first telegram from bus
Humidity hysteresislist0.8 %
Subordinated to temperature controllistyes
Humidity setpointunsignedInt 20…8055
Integrationlistno
Dehumidification start delaytime300
Temperature difference for integrationlist1.5 °C
Hysteresis for integrationlist0.5 K
Disable dehumid. control from buslistno
Humidity setpointunsignedInt 20…8035
Disable humidification control from buslistno
Analog sensors timeouttime300
Flow temperature (project)list14 °C
Min control valueunsignedInt 0…300
Max control valueunsignedInt 70…100100
Transmission delay after mode changetime400
Hysteresis positionlistbelow
Hysteresis positionlistabove
Delay for alarm signallist5 min
Heating - cooling switch overlistfrom bus
Thermostat functionlistheating
Heating - cooling cyclic sending intervallistno sending
Dehumidification functionlistdisabled
Humidification functionlistdisabled
Logic functionlistdisabled
Logic operationlistOR
Output cyclic sending intervallistno sending
Logic object 1listdisabled
Logic object 2listdisabled
Logic object 3listdisabled
Logic object 4listdisabled
Logic object 1 negatedlistno
Logic object 2 negatedlistno
Logic object 3 negatedlistno
Logic object 4 negatedlistno
Logic object 1 read at startuplistno
Logic object 2 read at startuplistno
Logic object 3 read at startuplistno
Logic object 4 read at startuplistno
Logic object 1 default valuelistnone
Logic object 2 default valuelistnone
Logic object 3 default valuelistnone
Logic object 4 default valuelistnone
Logic functionslistdisabled
Output sendinglistboth values
Output updatelistat value change
Setpoint typelistsingle
Disable temperature controller from buslistno
Cyclic reading eachlistno reading
Threshold value update from buslistno
Threshold lock enablelistno
Behaviour at locklistnone
Behaviour at bus recoverylistprevious state
Behaviour at bus recoverylistunlock
CO2 controllistdisabled
ValueunsignedInt 0…100001000
Hysteresislist150 ppm
Typelistnot active
Communication object dimensionlist1 bit value
Value (above)liston
Value (above)unsignedInt 0…2550
Percentage (above)unsignedInt 0…1000
Value (below)liston
Percentage (below)unsignedInt 0…1000
Value (below)unsignedInt 0…2550
Lock enablelistno
Valuelistoff
ValueunsignedInt 0…2550
PercentageunsignedInt 0…1000
Ventilationlistdisabled
Communication object dimensionlist1 byte percentage
Value < threshold 1unsignedInt 0…1000
Value < threshold 1unsignedInt 0…2550
Bit 1listoff
Bit 2listoff
Bit 3listoff
Bit 4listoff
Threshold 1 < value < threshold 2unsignedInt 0…1000
Threshold 1 < value < threshold 2unsignedInt 0…2550
Threshold 2 < value < threshold 3unsignedInt 0…1000
Threshold 2 < value < threshold 3unsignedInt 0…2550
Value > Threshold 3unsignedInt 0…1000
Value > Threshold 3unsignedInt 0…2550
Ventilation locklistdisabled
Behaviour after bus onlistprevious state
Lock valueunsignedInt 0…1000
Lock valueunsignedInt 0…2550
ValueunsignedInt 0…100001200
ValueunsignedInt 0…100001500
Temperature setpointfloat 10…5021
Neutral zonesignedInt 10…8020
HVAC mode after downloadlistno change
Min. outputunsignedInt 0…1000
Max. outputunsignedInt 0…100100
Min. CO2unsignedInt 0…10000850
Max. CO2unsignedInt 0…100001500
CO2 offsetlist0 ppm
Humidity offsetlist0 %
Indoor CO2listdisabled
Outdoor CO2listdisabled
TVOC sensorlistenabled
TVOC controllistdisabled
ValueunsignedInt 0…10000220
Hysteresislist60 ppb
ValueunsignedInt 0…10000660
ValueunsignedInt 0…100002200
Time scheduled ventilationlistdisabled
Frequencylist30 min
Time intervallist2 min
Led L7 and L8 (TVOC control)listenabled
Ventilationlist60 ppb
Min. TVOCunsignedInt 0…10000200
Max. TVOCunsignedInt 0…100001500
Flowmeterlistno
Maximum design rangefloat 0…1003
CO2 alarm functionlistdisabled
Threshold valueunsignedInt 0…100001000
Max. threshold exceedingunsignedInt 0…10010

Version history

ApplicationApp noFingerprintFirst seenSizeFile
APEKES3TP 0.1 latest$45534F1D2026-11-25230 KBDownload

About this file

This is the official ETS product database for the Ekinex S.p.A. Multisensor T, RH and CO2eq with controller (EK-ES3-TP), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.