Room temperature controller with LCD and relative humidity sensor EK-EQ2-TP
Ekinex S.p.A. · Order number EK-EQ2-TP · Heating, cooling and ventilation
Room temperature controller with LCD and relative humidity sensor
Download .knxprod APEKEQ2TP 0.1 · 238 KB
Product
| Manufacturer | Ekinex S.p.A. |
|---|---|
| Product name | Room temperature controller with LCD and relative humidity sensor |
| Order number | EK-EQ2-TP |
| Hardware | Room temperature controller with LCD and relative humidity sensor |
| Medium | Twisted Pair |
| Bus current (mA) | 12 |
| Rail mounted | No |
| Registration | Certified · 2017-04-07 |
| Languages | en-US, de-DE, fr-FR, it-IT |
| Catalog entry | M-00B6_H-000021-1_HP-4551-01-72B8_CI-EK.2DEQ2.2DTP-2 |
| Fingerprint | 72B8 |
| SHA-256 | 1cd80daa8d859a1a6c113778e7cb438718b7f8df861a771cd7e69cd6e7dbbac8 |
| First seen | 2026-11-25 |
| Markets | 69 markets |
Application program: APEKEQ2TP 0.1
| Application number | $4551 |
|---|---|
| Version | 0.1 |
| Mask version | MV-0705 (7.5) |
| KNX Data Secure | No |
| Minimum ETS version | 4.0 |
| Parameters | 1111 |
| Group objects | 110 |
Group objects (110)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Technical alarm | 1 Bit | 1.5 alarm | CW | |
| 1 | Brightness value | 2 Bytes | 9.4 lux (Lux) | CRT | |
| 2 | Leds intensity percentage | 1 Byte | 5.1 percentage (0..100%) | CW | |
| 3 | Temperature value | 2 Bytes | 9.1 temperature (°C) | CRT | |
| 20 | Light threshold 1 - Switch | 1 Bit | 1.1 switch | CRT | |
| 37 | Light threshold 2 - Switch | 1 Bit | 1.1 switch | CRT | |
| 38 | Rocker 1 - Led first color A | 1 Bit | 1.1 switch | CRWTU | |
| 39 | Rocker 1 - Led second color A | 1 Bit | 1.1 switch | CRWTU | |
| 40 | Rocker 1 - Led first color B | 1 Bit | 1.1 switch | CRWTU | |
| 41 | Rocker 1 - Led second color B | 1 Bit | 1.1 switch | CRWTU | |
| 76 | Rocker 2 - Led first color A | 1 Bit | 1.1 switch | CRWTU | |
| 77 | Rocker 2 - Led second color A | 1 Bit | 1.1 switch | CRWTU | |
| 78 | Rocker 2 - Led first color B | 1 Bit | 1.1 switch | CRWTU | |
| 79 | Rocker 2 - Led second color B | 1 Bit | 1.1 switch | CRWTU | |
| 114 | Humidity value (1 byte) | 1 Byte | 5.1 percentage (0..100%) | CRT | |
| 115 | Humidity value (2 bytes) | 2 Bytes | 9.7 humidity (%) | CRT | |
| 116 | Temperature threshold 1 - Switch | 1 Bit | 1.1 switch | CRT | |
| 117 | Temperature threshold 2 - Switch | 1 Bit | 1.1 switch | CRT | |
| 118 | Humidity threshold 1 - Switch | 1 Bit | 1.1 switch | CRT | |
| 119 | Humidity threshold 2 - Switch | 1 Bit | 1.1 switch | CRT | |
| 120 | Temperature value sensor (from input 1) | 2 Bytes | 9.1 temperature (°C) | CRT | |
| 120 | Coil battery temperature sensor (from input 1) | 2 Bytes | 9.1 temperature (°C) | CRT | |
| 120 | Room temperature sensor (from input 1) | 2 Bytes | 9.1 temperature (°C) | CRT | |
| 120 | Antistratification temperature sensor (from input 1) | 2 Bytes | 9.1 temperature (°C) | CRT | |
| 120 | Floor surface temperature sensor (from input 1) | 2 Bytes | 9.1 temperature (°C) | CRT | |
| 120 | Outdoor temperature sensor (from input 1) | 2 Bytes | 9.1 temperature (°C) | CRT | |
| 121 | Temperature threshold 1 sensor 1 - Switch | 1 Bit | 1.1 switch | CRT | |
| 122 | Temperature threshold 2 sensor 1 - Switch | 1 Bit | 1.1 switch | CRT | |
| 123 | Temperature value sensor (from input 2) | 2 Bytes | 9.1 temperature (°C) | CRT | |
| 123 | Coil battery temperature sensor (from input 2) | 2 Bytes | 9.1 temperature (°C) | CRT | |
| 123 | Room temperature sensor (from input 2) | 2 Bytes | 9.1 temperature (°C) | CRT | |
| 123 | Antistratification temperature sensor (from input 2) | 2 Bytes | 9.1 temperature (°C) | CRT | |
| 123 | Floor surface temperature sensor (from input 2) | 2 Bytes | 9.1 temperature (°C) | CRT | |
| 123 | Outdoor temperature sensor (from input 2) | 2 Bytes | 9.1 temperature (°C) | CRT | |
| 124 | Temperature threshold 1 sensor 2 - Switch | 1 Bit | 1.1 switch | CRT | |
| 125 | Temperature threshold 2 sensor 2 - Switch | 1 Bit | 1.1 switch | CRT | |
| 126 | Window contact sensor (from input 1) | 1 Bit | 1.19 window/door | CRT | |
| 127 | Window contact sensor (from input 2) | 1 Bit | 1.19 window/door | CRT | |
| 128 | Anticondensation sensor (from input 1) | 1 Bit | 1.5 alarm | CRT | |
| 129 | Anticondensation sensor (from input 2) | 1 Bit | 1.5 alarm | CRT | |
| 130 | Card holder contact sensor (from input 1) | 1 Bit | 1.18 occupancy | CRT | |
| 131 | Card holder contact sensor (from input 2) | 1 Bit | 1.18 occupancy | CRT | |
| 132 | Presence sensor 1 (from bus) | 1 Bit | 1.18 occupancy | CW | |
| 133 | Presence sensor 2 (from bus) | 1 Bit | 1.18 occupancy | CW | |
| 134 | Room temperature (from bus) | 2 Bytes | 9.1 temperature (°C) | CW | |
| 135 | Humidity (2 bytes, from bus) | 2 Bytes | 9.7 humidity (%) | CW | |
| 136 | Humidity (1 byte, from bus) | 1 Byte | 5.1 percentage (0..100%) | CW | |
| 137 | Antistratification temperature (from bus) | 2 Bytes | 9.1 temperature (°C) | CW | |
| 138 | Outdoor temperature (from bus) | 2 Bytes | 9.1 temperature (°C) | CW | |
| 139 | Air quality (from bus) | 2 Bytes | 9.8 parts/million (ppm) | CW | |
| 140 | Coil temperature (from bus) | 2 Bytes | 9.1 temperature (°C) | CW | |
| 141 | Floor temperature (from bus) | 2 Bytes | 9.1 temperature (°C) | CW | |
| 142 | Flow temperature (from bus) | 2 Bytes | 9.1 temperature (°C) | CW | |
| 143 | Windows contact sensor 1 (from bus) | 1 Bit | 1.19 window/door | CW | |
| 144 | Windows contact sensor 2 (from bus) | 1 Bit | 1.19 window/door | CW | |
| 145 | Contact of card holder (from bus) | 1 Bit | 1.18 occupancy | CW | |
| 146 | Anticondensation (from bus) | 1 Bit | 1.1 switch | CW | |
| 147 | Weighted temperature | 2 Bytes | 9.1 temperature (°C) | CRT | |
| 148 | Heating/cooling status out | 1 Bit | 1.100 heating/cooling | CRT | |
| 149 | Heating/cooling status in | 1 Bit | 1.100 heating/cooling | CW | |
| 150 | HVAC mode in | 1 Byte | 20.102 HVAC mode | CW | |
| 151 | HVAC forced mode in | 1 Byte | 20.102 HVAC mode | CW | |
| 152 | Actual setpoint | 2 Bytes | 9.1 temperature (°C) | CRT | |
| 153 | Comfort setpoint (heating) | 2 Bytes | 9.1 temperature (°C) | CRWTU | |
| 154 | Comfort setpoint (cooling) | 2 Bytes | 9.1 temperature (°C) | CRWTU | |
| 155 | Standby setpoint (heating) | 2 Bytes | 9.1 temperature (°C) | CRWTU | |
| 156 | Standby setpoint (cooling) | 2 Bytes | 9.1 temperature (°C) | CRWTU | |
| 157 | Economy setpoint (heating) | 2 Bytes | 9.1 temperature (°C) | CRWTU | |
| 158 | Economy setpoint (cooling) | 2 Bytes | 9.1 temperature (°C) | CRWTU | |
| 159 | Building protection setpoint (heating) | 2 Bytes | 9.1 temperature (°C) | CRWTU | |
| 160 | Building protection setpoint (cooling) | 2 Bytes | 9.1 temperature (°C) | CRWTU | |
| 161 | Heating out command | 1 Byte | 5.1 percentage (0..100%) | CRT | |
| 161 | Heating out command | 1 Bit | 1.1 switch | CRT | |
| 161 | Heating and cooling out command | 1 Bit | 1.1 switch | CRT | |
| 161 | Heating and cooling out command | 1 Byte | 5.1 percentage (0..100%) | CRT | |
| 162 | Cooling out command | 1 Byte | 5.1 percentage (0..100%) | CRT | |
| 162 | Cooling out command | 1 Bit | 1.1 switch | CRT | |
| 163 | Auxiliary heating output command | 1 Bit | 1.1 switch | CRT | |
| 163 | Auxiliary heating and cooling output command | 1 Bit | 1.1 switch | CRT | |
| 164 | Auxiliary cooling output command | 1 Bit | 1.1 switch | CRT | |
| 165 | Auxiliary heating disable | 1 Bit | 1.3 enable | CW | |
| 166 | Auxiliary cooling disable | 1 Bit | 1.3 enable | CW | |
| 167 | Fan continuous speed | 1 Byte | 5.1 percentage (0..100%) | CRT | |
| 168 | Fan speed 1 | 1 Bit | 1.1 switch | CRT | |
| 169 | Fan speed 2 | 1 Bit | 1.1 switch | CRT | |
| 170 | Fan speed 3 | 1 Bit | 1.1 switch | CRT | |
| 172 | Fan control disable | 1 Bit | 1.2 boolean | CW | |
| 173 | HVAC scene number | 1 Byte | 17.1 scene number | CW | |
| 174 | Comfort state | 1 Bit | 1.6 binary value | CRT | |
| 175 | Dew-point temperature | 2 Bytes | 9.1 temperature (°C) | CRT | |
| 176 | Perceived temperature | 2 Bytes | 9.1 temperature (°C) | CRT | |
| 179 | HVAC mode out | 1 Byte | 20.102 HVAC mode | CRT | |
| 180 | Dehumidification command | 1 Bit | 1.1 switch | CRT | |
| 181 | Dehumidification control disable | 1 Bit | 1.2 boolean | CW | |
| 182 | Dehumidification water battery command | 1 Bit | 1.1 switch | CRT | |
| 183 | Dehumidification integration control | 1 Bit | 1.1 switch | CRT | |
| 184 | Humidification command | 1 Bit | 1.1 switch | CRT | |
| 185 | Humidification control disable | 1 Bit | 1.2 boolean | CW | |
| 186 | Temperature setpoint change lock | 1 Bit | 1.3 enable | CW | |
| 187 | Manual mode lock | 1 Bit | 1.3 enable | CW | |
| 188 | Anticondensation alarm | 1 Bit | 1.5 alarm | CRT | |
| 189 | Rockers lock | 1 Bit | 1.2 boolean | CW | |
| 190 | Ventilation manual operation | 1 Bit | 1.11 state | CRT | |
| 191 | Thermal generator lock | 1 Bit | 1.5 alarm | CW | |
| 192 | Alarm 1 (from bus) | 1 Bit | 1.5 alarm | CW | |
| 193 | Alarm 2 (from bus) | 1 Bit | 1.5 alarm | CW | |
| 194 | Alarm 3 (from bus) | 1 Bit | 1.5 alarm | CW | |
| 195 | Alarm 4 (from bus) | 1 Bit | 1.5 alarm | CW | |
| 196 | Relative humidity setpoint for dehumidification | 2 Bytes | 9.7 humidity (%) | CRWTU | |
| 197 | Relative humidity setpoint for humidification | 2 Bytes | 9.7 humidity (%) | CRWTU |
Parameters (270)
| Parameter | Type | Default |
|---|---|---|
| Light sensor | list | disabled |
| Temperature sensor | list | enabled |
| Rocker 1 | list | independent or single |
| Rocker 2 | list | copy parameters from rocker 1 |
| Input 1 | list | disabled |
| Led intensity correlation | list | none |
| Minimum change of value to send [Lux] | float 0…670760 | 50 |
| Cyclic sending interval | list | no sending |
| Minimum change of value to send [K] | float 0…5 | 0.5 |
| Delay after bus voltage recovery | time | 400 |
| Function A | list | enabled |
| Long press time | time | 300 |
| Lock function | list | disabled |
| Invert lock device signal | list | not inverted |
| Lock after bus recovery | list | no |
| Type | list | send values or sequences |
| Number of Communication Objects | unsignedInt 1…8 | 1 |
| Event | list | activation / release |
| Behaviour at locking | list | none |
| Behaviour at unlocking | list | none |
| Send cyclically | list | none |
| Cyclic sending interval | list | 5 min |
| Send delay | time | 0 |
| Communication object dimension | list | 1 bit value |
| Reaction to activation | list | toggle |
| Reaction to release | list | off |
| Reaction to short press | list | toggle |
| Reaction to long press | list | off |
| Reaction to activation | list | enable on / down |
| Reaction to release | list | disable |
| Reaction to short press | list | enable on / down |
| Reaction to long press | list | disable |
| Reaction to activation | list | send value 1 |
| Reaction to release | list | none |
| Reaction to short press | list | send value 1 |
| Reaction to long press | list | none |
| Value 1 | unsignedInt 0…255 | 0 |
| Value 2 | unsignedInt 0…255 | 0 |
| Value 1 | signedInt -128…127 | 0 |
| Value 2 | signedInt -128…127 | 0 |
| Value 1 | unsignedInt 0…65535 | 0 |
| Value 2 | unsignedInt 0…65535 | 0 |
| Value 1 | signedInt -32768…32767 | 0 |
| Value 2 | signedInt -32768…32767 | 0 |
| Value 1 | float -671088.64…670760.96 | 0 |
| Value 2 | float -671088.64…670760.96 | 0 |
| Reaction to activation | list | on |
| Reaction to short press | list | on |
| Toggle mode | list | enabled |
| Short / long action | list | off / darker |
| Up / down action | list | up |
| Venetian blind mode | list | disabled |
| Learning mode | list | disabled |
| Scene activation | list | send first scene only |
| First scene number | unsignedInt 1…64 | 1 |
| Second scene number | unsignedInt 1…64 | 2 |
| Function B | list | copy parameters from function A |
| Type | list | dimming |
| 1A and 1B use | list | A increases, B decreases |
| 1A and 1B use | list | A up, B down |
| Leds intensity from bus | list | no |
| Leds intensity | list | 50 % |
| Led first color 1A | list | when contact closed |
| Blinking | list | no |
| Signal from bus | list | not inverted |
| Always | list | off |
| Off delay | time | 20 |
| Blinking period / type | list | 1 s on, 1 s off |
| 1A and 1B use | list | A on, B off |
| Led second color 1A | list | when contact closed |
| Led second color 1B | list | when contact closed |
| Led first color 1B | list | when contact closed |
| 2A and 2B use | list | A on, B off |
| 2A and 2B use | list | A increases, B decreases |
| 2A and 2B use | list | A up, B down |
| Led first color 2A | list | when contact closed |
| Led second color 2A | list | when contact closed |
| Led first color 2B | list | when contact closed |
| Led second color 2B | list | when contact closed |
| Value [Lux] | float 0…670760 | 500 |
| Hysteresis | list | 50 lux |
| Threshold 1 | list | not active |
| Threshold 2 | list | not active |
| Sensor value multiplier (1 ÷ 255) x 0.1 | unsignedInt 1…255 | 10 |
| Reaction to long press | list | darker |
| Temperature offset | list | 0.0 °C |
| Technical alarm | list | disabled |
| Value 1 | unsignedInt 0…100 | 0 |
| Value 2 | unsignedInt 0…100 | 0 |
| Input 2 | list | disabled |
| Contact type | list | NO (normally open) |
| Relative humidity sensor | list | disabled |
| Value [°C] | float 0…50 | 45 |
| Value [°C] | float 0…50 | 7 |
| Hysteresis | list | 0.4 K |
| Value [%] | unsignedInt 0…100 | 65 |
| Hysteresis [%] | list | 3.0 % |
| Minimum change of value to send [%] | unsignedInt 0…10 | 2 |
| Temperature displayed unit | list | Celsius |
| Default displayed information | list | actual temperature |
| Time to return to default display | list | 5 s |
| Button function level | list | system integrator |
| Time to exit change without saving | list | 10 s |
| Debounce time | time | 20 |
| Value [°C] | float -20…50 | 7 |
| Value [°C] | float -20…50 | 45 |
| Digital sensors timeout | time | 300 |
| Room temperature | list | disabled |
| Relative humidity | list | disabled |
| Antistratification temperature | list | disabled |
| Outdoor temperature | list | disabled |
| Air quality | list | disabled |
| Coil temperature | list | disabled |
| Floor surface temperature | list | disabled |
| Flow temperature | list | disabled |
| Window contact 1 | list | disabled |
| Window contact 2 | list | disabled |
| Presence sensor 1 | list | disabled |
| Presence sensor 2 | list | disabled |
| Card holder contact | list | disabled |
| Humidity CO dimension | list | 2 bytes |
| Main source for temperature value | list | internal sensor |
| Additional source temperature value | list | internal sensor |
| Relative weight | list | 50% / 50% |
| Filter type | list | medium |
| Main source for temperature value | list | input |
| Additional source temperature value | list | input |
| Additional source temperature value | list | from bus |
| Anticondensation | list | disabled |
| Max manual temperature change | list | ±3 °C |
| Max setpoint temperature change | list | ±9 °C |
| Setpoint cyclic sending interval | list | no sending |
| Scenes | list | disabled |
| Comfort temp. setpoint [°C] | float 10…50 | 21 |
| Standby temperature setpoint [°C] | float 10…50 | 18 |
| Economy temp. setpoint [°C] | float 10…50 | 16 |
| Building protection temp. setpoint [°C] | float 2…10 | 7 |
| Control type | list | 2 points hysteresis |
| Command Communication Object | list | separated |
| Hysteresis | list | 0.3 K |
| PWM cycle time | time | 15 |
| Proportional band [0.1K] | unsignedInt 5…100 | 40 |
| Integral time [min] | unsignedInt 0…255 | 90 |
| Valve protection function | list | disabled |
| Frequency | list | once a week |
| Time interval | list | 10 s |
| Floor temperature limitation | list | disabled |
| Temperature limit [°C] | float 20…40 | 29 |
| Auxiliary heating | list | disabled |
| Communication object | list | separated |
| Offset from setpoint | list | 0.6 K |
| Disabled from bus | list | no |
| Ventilation for auxiliary heating | list | disabled |
| Comfort temp. setpoint [°C] | float 10…50 | 23 |
| Standby temperature setpoint [°C] | float 10…50 | 26 |
| Economy temp. setpoint [°C] | float 10…50 | 28 |
| Building protection temp. setpoint [°C] | float 30…50 | 36 |
| Cooling type | list | fancoils |
| Auxiliary cooling | list | disabled |
| Anticondensation with probe | list | disabled |
| Active anticondensation | list | disabled |
| Min. change of value to send [%] | unsignedInt 0…100 | 10 |
| Anticondensation hysteresis range | list | 0.5 K |
| Control type | list | 1 speed |
| Threshold first speed [0.1K] | unsignedInt 0…255 | 0 |
| Threshold second speed [0.1K] | unsignedInt 0…255 | 10 |
| Threshold third speed [0.1K] | unsignedInt 0…255 | 20 |
| Manual operation | list | not depending on the temperature |
| Hot start | list | no |
| Use coil battery temperature sensor for dehumidification | list | no |
| Speed control hysteresis | list | 0.3 K |
| Speed proportional band [0.1K] | unsignedInt 5…100 | 30 |
| Min. change of value to send [%] | unsignedInt 2…40 | 10 |
| Min. temp. to start ventilation [°C] | unsignedInt 28…40 | 28 |
| Min. temp. to start dehumidif. [°C] | unsignedInt 0…255 | 10 |
| Relative humidity setpoint [%] | unsignedInt 0…100 | 65 |
| Relative humidity setpoint [%] | list | 0.6 % |
| Max. temp. diff. to disable dehum. [°C] | float 0…50 | 0.5 |
| Forced speed | list | 1 speed |
| Forced speed | unsignedInt 0…100 | 20 |
| Antistratification function | list | disabled |
| Antistratification temp. differential | list | 2.00 [K/m] |
| Hysteresis | list | 0.5 K |
| Disable ventilation from bus | list | no |
| Fan start delay | list | 0 s |
| Fan stop delay | list | 0 s |
| Download overwrite | list | disabled |
| Scene 1 | list | disabled |
| Scene 2 | list | disabled |
| Scene 3 | list | disabled |
| Scene 4 | list | disabled |
| Scene 5 | list | disabled |
| Scene 6 | list | disabled |
| Scene 7 | list | disabled |
| Scene 8 | list | disabled |
| HVAC mode | list | comfort |
| Scene number | unsignedInt 1…64 | 1 |
| Activation delay | time | 0 |
| Minimum temperature [°C] | float 10…50 | 20 |
| Maximum temperature [°C] | float 10…50 | 26 |
| Minimum relative humidity [%] | unsignedInt 0…100 | 30 |
| Maximum relative humidity [%] | unsignedInt 0…100 | 65 |
| Maximum absolute humidity [g/kg x 0,1] | unsignedInt 50…200 | 115 |
| Dew-point temperature | list | disabled |
| Perceived temperature | list | disabled |
| Enthalpy | list | disabled |
| Absolute humidity | list | disabled |
| Min. change of value to send [K] | list | 0.2 K |
| Min. change of value to send | list | 0.2 K |
| Min. change of value to send | list | 5.0 kJ/kg |
| Min. change of value to send | list | 0.1 gv/kga |
| Windows contacts function | list | disabled |
| Presence sensors function | list | disabled |
| Presence sensors use | list | comfort extension |
| Thermostat modes | list | comfort - standby |
| Wait time to building protection mode | time | 60 |
| Absence time to switch HVAC mode | time | 60 |
| Signal | list | not inverted |
| Device operation as | list | stand-alone |
| Use rockers as | list | thermostat predefined functions |
| Main source for temperature value | list | input 1 |
| Additional source temperature value | list | input 1 |
| Additional source temperature value | list | input 2 |
| Actual temperature | list | always enabled |
| Temperature setpoint | list | enabled |
| Relative humidity | list | enabled |
| Relative humidity setpoint | list | enabled |
| Perceived temperature | list | enabled |
| Outdoor temperature | list | enabled |
| Air quality | list | enabled |
| Card holder function | list | disabled |
| On card insertion switch HVAC mode to | list | comfort |
| On card removal switch HVAC mode to | list | standby |
| Activation delay on card insertion | time | 0 |
| Activation delay on card removal | time | 0 |
| Backlight intensity | list | 50 % |
| Automatic backlight dimming | list | disabled |
| Energy saving | list | disabled |
| Visualization type | list | full |
| Time before energy saving mode | list | 10 s |
| Backlight when in energy saving mode | list | 25 % |
| Behaviour on button press | list | backlight only |
| Ventilation for auxiliary cooling | list | disabled |
| Heating type | list | radiators |
| Heating type | list | fancoils |
| End of manual operation | list | till first telegram from bus |
| Humidity hysteresis | list | 0.8 % |
| Subordinated to temperature control | list | yes |
| Humidity setpoint | unsignedInt 20…80 | 55 |
| Integration | list | no |
| Dehumidification start delay | time | 300 |
| Temperature difference for integration | list | 1.5 °C |
| Hysteresis for integration | list | 0.5 K |
| Disable dehumid. control from bus | list | no |
| Humidity setpoint | unsignedInt 20…80 | 35 |
| Disable humidification control from bus | list | no |
| Duration of comfort extension | list | not allowed |
| Analog sensors timeout | time | 300 |
| Flow temperature (project) | list | 14 °C |
| Min control value [%] | unsignedInt 0…30 | 15 |
| Max control value [%] | unsignedInt 70…100 | 85 |
| Transmission delay after mode change | time | 400 |
| Hysteresis position | list | below |
| Hysteresis position | list | above |
| Delay for alarm signal | list | 5 min |
| Heating - cooling switch over | list | from bus |
| Thermostat function | list | heating |
| Heating - cooling cyclic sending interval | list | no sending |
| Dehumidification function | list | disabled |
| Humidification function | list | disabled |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| APEKEQ2TP 0.4 latest | $4551 | AB69 | 2026-11-25 | 175 KB | Download |
| APEKEQ2TP 0.3 | $4551 | 5C66 | 2026-11-25 | 162 KB | Download |
| APEKEQ2TP 0.2 | $4551 | 2FF5 | 2026-11-25 | 162 KB | Download |
| APEKEQ2TP 0.1 | $4551 | 72B8 | 2026-11-25 | 238 KB | Download |
About this file
This is the official ETS product database for the Ekinex S.p.A. Room temperature controller with LCD and relative humidity sensor (EK-EQ2-TP), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from Ekinex S.p.A.
- Universal interface 4 DI + 4 DI / NTC EK-CA1-TP
- Universal interface 4 DI / 2 relais 5A EK-CE2-TP
- Universal interface 4 DI / NTC EK-CG2-TP
- Room temperature controller 71 Serie EK-E72-TP
- Room temperature controller 71 Serie - EASY EK-E73-EASY
- Room temperature controller 71 Serie EK-E73-TP
- Touch & See with integrated pushbutton 2 channels EK-EF2-TP
- Easy room temperature controller with LCD EK-EM2-TP-E
- Full room temperature controller with LCD EK-EM2-TP-F
- Room temperature controller with LCD EK-EP2-TP
- Easy room temperature Easy controller with LCD EK-ER2-TP
- Multisensor T, RH and CO2eq with controller EK-ES2-TP