| 0 | Output, Error code | Error code | 4 Bytes | | CRT |
| 1 | Input, Calibration | Calibrationvalue | 4 Bytes | | CRWU |
| 2 | Output, measured value soil moisture | Measured value | 2 Bytes | 9.1 temperature (°C) | CRT |
| 2 | Output, measured value soil moisture | Measured value | 4 Bytes | 14.5 amplitude | CRT |
| 3 | Input, auxiliary object soil moisture | Auxiliary object | 2 Bytes | 9.1 temperature (°C) | CRWU |
| 3 | Input, auxiliary object soil moisture | Auxiliary object | 4 Bytes | 14.5 amplitude | CRWU |
| 4 | Output, upper limit soil moisture | Exceeding limit | 1 Bit | 1.2 boolean | CRT |
| 5 | Output, lower limit soil moisture | Undercut limit | 1 Bit | 1.2 boolean | CRT |
| 6 | Output, controller soil moisture | Actuating value | 1 Bit | 1.1 switch | CRT |
| 6 | Output, controller soil moisture | Actuating value | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 7 | Input, enable/lock controller | Enable/lock | 1 Bit | 1.1 switch | CRWU |
| 8 | Output, status object soil moisture | Status | 1 Byte | | CRT |
| 9 | Output, soil temperature | Measured value | 4 Bytes | 14.68 temperature (°C) | CRT |
| 9 | Output, soil temperature | Measured value | 1 Byte | 6.10 counter pulses (-128..127) | CRT |
| 9 | Output, soil temperature | Measured value | 2 Bytes | 8.1 pulses difference | CRT |
| 9 | Output, soil temperature | Measured value | 2 Bytes | 9.1 temperature (°C) | CRT |
| 10 | Input, auxiliary object soil temperature | Auxiliary object | 4 Bytes | 14.68 temperature (°C) | CRWU |
| 10 | Input, auxiliary object soil temperature | Auxiliary object | 1 Byte | 6.10 counter pulses (-128..127) | CRWU |
| 10 | Input, auxiliary object soil temperature | Auxiliary object | 2 Bytes | 8.1 pulses difference | CRWU |
| 10 | Input, auxiliary object soil temperature | Auxiliary object | 2 Bytes | 9.1 temperature (°C) | CRWU |
| 11 | Output, upper limit soil temperature | Limit | 1 Bit | 1.1 switch | CRT |
| 12 | Output, lower limit soil temperature | Limit | 1 Bit | 1.1 switch | CRT |
| 13 | Output, controller soil temperature | Actuating value | 1 Bit | 1.1 switch | CRT |
| 13 | Output, controller soil temperature | Actuating value | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 14 | Input, enable/lock soil temperature | Enable/lock | 1 Bit | 1.1 switch | CRWU |
| 15 | Output, status object soil temperature | Channel status | 1 Byte | | CRT |
| 16 | Output, Measured value C3 | Measured value | 4 Bytes | 14.5 amplitude | CRT |
| 17 | Input, Auxiliary object C3 | Auxiliary object | 4 Bytes | 14.5 amplitude | CRWU |
| 18 | Output, runtime upper limit | Exceeding limit | 1 Bit | 1.2 boolean | CRT |
| 19 | Output, runtime lower limit | Undercut limit | 1 Bit | 1.2 boolean | CRT |
| 20 | Output, Controler C3 | Actuating value | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 21 | Input, Enable/lock C3 | Enable/lock | 1 Bit | 1.1 switch | CRWU |
| 22 | Output, Object status C3 | Channel status | 1 Byte | | CRT |
| 23 | Output, measured value soil temperature | Measured value | 4 Bytes | 14.68 temperature (°C) | CRT |
| 24 | Input, auxiliary object K4 | Auxiliary object | 2 Bytes | 9.1 temperature (°C) | CRWU |
| 25 | Output, upper limit soil temperature | Limit | 1 Bit | 1.1 switch | CRT |
| 26 | Output, lower limit soil temperature | Limit | 1 Bit | 1.1 switch | CRT |
| 27 | Output, Controler C5 | Actuating value | 1 Bit | 1.1 switch | CRT |
| 28 | Input, Enable/lock C4 | Enable/lock | 1 Bit | 1.1 switch | CRWU |
| 29 | Output, Object status C4 | Channel status | 1 Byte | | CRT |
| 30 | Output, measured value dewpoint temperature | Calculated value | 1 Byte | 6.10 counter pulses (-128..127) | CRT |
| 30 | Output, measured value dewpoint temperature | Calculated value | 2 Bytes | 8.1 pulses difference | CRT |
| 30 | Output, measured value dewpoint temperature | Calculated value | 2 Bytes | 9.1 temperature (°C) | CRT |
| 30 | Output, measured value dewpoint temperature | Calculated value | 4 Bytes | 14.68 temperature (°C) | CRT |
| 31 | Input, auxiliary object dewpoint temperature | Auxiliary object | 2 Bytes | 8.1 pulses difference | CRWU |
| 31 | Input, auxiliary object dewpoint temperature | Auxiliary object | 1 Byte | 6.10 counter pulses (-128..127) | CRWU |
| 31 | Input, auxiliary object dewpoint temperature | Auxiliary object | 2 Bytes | 9.1 temperature (°C) | CRWU |
| 31 | Input, auxiliary object dewpoint temperature | Auxiliary object | 4 Bytes | 14.68 temperature (°C) | CRWU |
| 32 | Output, upper limit dewpoint temperature | Limit | 1 Bit | 1.1 switch | CRT |
| 33 | Output, lower limit dewpoint temperature | Limit | 1 Bit | 1.1 switch | CRT |
| 34 | Output, Controler C5 | Actuating value | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 35 | Input, Enable/lock C5 | Enable/lock | 1 Bit | 1.1 switch | CRWU |
| 36 | Output, Channel status C5 | Channel status | 1 Byte | | CRT |
| 37 | Output, measured value absolute humidity | Calculated value | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 37 | Output, measured value absolute humidity | Calculated value | 2 Bytes | 7.1 pulses | CRT |
| 37 | Output, measured value absolute humidity | Calculated value | 2 Bytes | 9.1 temperature (°C) | CRT |
| 37 | Output, measured value absolute humidity | Calculated value | 4 Bytes | 14.5 amplitude | CRT |
| 38 | Input, auxiliary object absolute humidity | Auxiliary object | 2 Bytes | 7.1 pulses | CRWU |
| 38 | Input, auxiliary object absolute humidity | Auxiliary object | 1 Byte | 5.10 counter pulses (0..255) | CRWU |
| 38 | Input, auxiliary object absolute humidity | Auxiliary object | 2 Bytes | 9.1 temperature (°C) | CRWU |
| 38 | Input, auxiliary object absolute humidity | Auxiliary object | 4 Bytes | 14.5 amplitude | CRWU |
| 39 | Output, upper limit absolute humidity | Limit | 1 Bit | 1.1 switch | CRT |
| 40 | Output, lower limit absolute humidity | Limit | 1 Bit | 1.1 switch | CRT |
| 41 | Object 42 | Nicht Verwendet | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 42 | Object 43 | Nicht Verwendet | 1 Bit | 1.1 switch | CRWU |
| 43 | Object 44 | Nicht Verwendet | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 44 | Output, measured value relative humidity | Measured value | 1 Byte | 6.10 counter pulses (-128..127) | CRT |
| 44 | Output, measured value relative humidity | Measured value | 2 Bytes | 8.1 pulses difference | CRT |
| 44 | Output, measured value relative humidity | Measured value | 2 Bytes | 9.1 temperature (°C) | CRT |
| 44 | Output, measured value relative humidity | Measured value | 4 Bytes | 14.5 amplitude | CRT |
| 45 | Input, auxiliary object relative humidity | Auxiliary object | 2 Bytes | 8.1 pulses difference | CRWU |
| 45 | Input, auxiliary object relative humidity | Auxiliary object | 1 Byte | 6.10 counter pulses (-128..127) | CRWU |
| 45 | Input, auxiliary object relative humidity | Auxiliary object | 2 Bytes | 9.1 temperature (°C) | CRWU |
| 45 | Input, auxiliary object relative humidity | Auxiliary object | 4 Bytes | 14.5 amplitude | CRWU |
| 46 | Output, upper limit relative humidity | Limit | 1 Bit | 1.1 switch | CRT |
| 47 | Output, lower limit relative humidity | Limit | 1 Bit | 1.1 switch | CRT |
| 48 | Output, controller relative humidity | Actuating value | 1 Bit | 1.1 switch | CRT |
| 48 | Output, controller relative humidity | Actuating value | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 49 | Input, enable/lock relative humidity | Enable/lock | 1 Bit | 1.1 switch | CRWU |
| 50 | Output, Object status relative humidity | Channel status | 1 Byte | | CRT |
| 51 | Output, measured value air temperature | Measured value | 1 Byte | 6.10 counter pulses (-128..127) | CRT |
| 51 | Output, measured value air temperature | Measured value | 2 Bytes | 8.1 pulses difference | CRT |
| 51 | Output, measured value air temperature | Measured value | 2 Bytes | 9.1 temperature (°C) | CRT |
| 51 | Output, measured value air temperature | Measured value | 4 Bytes | 14.68 temperature (°C) | CRT |
| 52 | Input, auxiliary object air temperature | Auxiliary object | 2 Bytes | 8.1 pulses difference | CRWU |
| 52 | Input, auxiliary object air temperature | Auxiliary object | 1 Byte | 6.10 counter pulses (-128..127) | CRWU |
| 52 | Input, auxiliary object air temperature | Auxiliary object | 2 Bytes | 9.1 temperature (°C) | CRWU |
| 52 | Input, auxiliary object air temperature | Auxiliary object | 4 Bytes | 14.68 temperature (°C) | CRWU |
| 53 | Output, upper limit air temperature | Limit | 1 Bit | 1.1 switch | CRT |
| 54 | Output, lower limit air temperature | Limit | 1 Bit | 1.1 switch | CRT |
| 55 | Output, controller K8 | Actuating value | 1 Bit | 1.1 switch | CRT |
| 55 | Output, controller K8 | Actuating value | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 56 | Input, enable/lock air temperature | Enable/lock | 1 Bit | 1.1 switch | CRWU |
| 57 | Output, Object status air temperature | Channel status | 1 Byte | | CRT |
| 58 | Time | Time | 3 Bytes | 10.1 time of day | CRWU |
| 59 | Date | Date | 3 Bytes | 11.1 date | CRWU |