KNX Database

S8-GLBS 30804XXX

Arcus-eds · Order number 30804XXX · Arc_S8

Download .knxprod SK08-GLBS 1.5 · 70 KB

Product

ManufacturerArcus-eds
Product nameS8-GLBS
Order number30804XXX
HardwareS8-GLBS
MediumTwisted Pair
Rail mountedNo
RegistrationCertified · 2011-12-07
Languagesen-US, de-DE
Catalog entryM-0076_H-30804XXX-0_HP-0026-15-002D_CI-30804XXX-1
Fingerprint002D
SHA-256ced021b696553a045c7d3ed08dec51f034a99a16173a3e294034a217d690d19e
First seen2026-11-25
Markets18 markets

Application program: SK08-GLBS 1.5

Application number$0026
Version1.5
Mask versionMV-0701 (7.1)
KNX Data SecureNo
Minimum ETS version3.0d
Parameters39
Group objects65
Group objects (65)
NoNameFunctionSizeDPTFlags
0Output, error codeError code4 BytesCRWU
1Input, calibrationCalibration value4 BytesCRWU
2Output, measured value W/m2Measured value2 Bytes7.1 pulsesCRT
2Output, measured value W/m2Measured value2 Bytes9.1 temperature (°C)CRT
2Output, measured value W/m2Measured value4 Bytes14.56 power (W)CRT
3Input, auxiliary object W/m2Auxiliary object2 Bytes7.1 pulsesCRWU
3Input, auxiliary object W/m2Auxiliary object2 Bytes9.1 temperature (°C)CRWU
3Input, auxiliary object W/m2Auxiliary object4 Bytes14.56 power (W)CRWU
4Output, upper limit W/m2Exceeding limit1 Bit1.2 booleanCRT
5Output, lower limit W/m2Undercut limit1 Bit1.2 booleanCRT
6Output, controller W/m2Actuating value1 Bit1.1 switchCRT
6Output, controller W/m2Actuating value1 Byte5.10 counter pulses (0..255)CRT
7Input, enable/lock controllerEnable/lock1 Bit1.1 switchCRWU
8Output, status object W/m2Status1 ByteCRT
9Object 10Nicht Verwendet4 Bytes14.5 amplitudeCRT
10Object 11Nicht Verwendet4 Bytes14.5 amplitudeCRT
11Object 12Nicht Verwendet1 Bit1.1 switchCRT
12Object 13Nicht Verwendet1 Bit1.1 switchCRT
13Object 14Nicht Verwendet1 Byte5.10 counter pulses (0..255)CRT
14Object 15Nicht Verwendet1 Bit1.1 switchCRWU
15Object 16Nicht Verwendet1 Byte5.10 counter pulses (0..255)CRT
16Object 17Nicht Verwendet4 Bytes14.5 amplitudeCRT
17Object 18Nicht Verwendet4 Bytes14.5 amplitudeCRT
18Object 19Nicht Verwendet1 Bit1.1 switchCRT
19Object 20Nicht Verwendet1 Bit1.1 switchCRT
20Object 21Nicht Verwendet1 Byte5.10 counter pulses (0..255)CRT
21Object 22Nicht Verwendet1 Bit1.1 switchCRWU
22Object 23Nicht Verwendet1 Byte5.10 counter pulses (0..255)CRT
23Object 24Nicht Verwendet4 Bytes14.5 amplitudeCRT
24Object 25Nicht Verwendet4 Bytes14.5 amplitudeCRT
25Object 26Nicht Verwendet1 Bit1.1 switchCRT
26Object 27Nicht Verwendet1 Bit1.1 switchCRT
27Object 28Nicht Verwendet1 Byte5.10 counter pulses (0..255)CRT
28Object 29Nicht Verwendet1 Bit1.1 switchCRWU
29Object 30Nicht Verwendet1 Byte5.10 counter pulses (0..255)CRT
30Object 31Nicht Verwendet4 Bytes14.5 amplitudeCRT
31Object 32Nicht Verwendet4 Bytes14.5 amplitudeCRT
32Object 33Nicht Verwendet1 Bit1.1 switchCRT
33Object 34Nicht Verwendet1 Bit1.1 switchCRT
34Object 35Nicht Verwendet1 Byte5.10 counter pulses (0..255)CRT
35Object 36Nicht Verwendet1 Bit1.1 switchCRWU
36Object 37Nicht Verwendet1 Byte5.10 counter pulses (0..255)CRT
37Object 38Nicht Verwendet4 Bytes14.5 amplitudeCRT
38Object 39Nicht Verwendet4 Bytes14.5 amplitudeCRT
39Object 40Nicht Verwendet1 Bit1.1 switchCRT
40Object 41Nicht Verwendet1 Bit1.1 switchCRT
41Object 42Nicht Verwendet1 Byte5.10 counter pulses (0..255)CRT
42Object 43Nicht Verwendet1 Bit1.1 switchCRWU
43Object 44Nicht Verwendet1 Byte5.10 counter pulses (0..255)CRT
44Object 45Nicht Verwendet4 Bytes14.5 amplitudeCRT
45Object 46Nicht Verwendet4 Bytes14.5 amplitudeCRT
46Object 47Nicht Verwendet1 Bit1.1 switchCRT
47Object 48Nicht Verwendet1 Bit1.1 switchCRT
48Object 49Nicht Verwendet1 Byte5.10 counter pulses (0..255)CRT
49Object 50Nicht Verwendet1 Bit1.1 switchCRWU
50Object 51Nicht Verwendet1 Byte5.10 counter pulses (0..255)CRT
51Object 52Nicht Verwendet4 Bytes14.5 amplitudeCRT
52Object 53Nicht Verwendet4 Bytes14.5 amplitudeCRT
53Object 54Nicht Verwendet1 Bit1.1 switchCRT
54Object 55Nicht Verwendet1 Bit1.1 switchCRT
55Object 56Nicht Verwendet1 Byte5.10 counter pulses (0..255)CRT
56Object 57Nicht Verwendet1 Bit1.1 switchCRWU
57Object 58Nicht Verwendet1 Byte5.10 counter pulses (0..255)CRT
58Equipment timeTime3 Bytes10.1 time of dayCRWU
59Equipment dateDate3 Bytes11.1 dateCRWU
Parameters (39)
ParameterTypeDefault
General settingslist0
Measured value send cycle periodlist1 min
Actuating value send cycle period ( Seconds )unsignedInt 10…25060
Kalibrierungszeit in TagenunsignedInt 0…25590
Use clock timerlistno
Timer fromunsignedInt 0…240
Timer untilunsignedInt 0…2424
Measured value global radiationlist0
Measured value send cyclicallistno
Measured value send by changelistno
Value typelist2byte float
Auxiliary object islistSetpoint
Auxiliary value store by changelistno
Lower limit W/m2signedInt 0…1800400
Unterer Grenzwert ( *10^X )signedInt -100…1000
Upper limit W/m2signedInt 0…18001000
Oberer Grenzwert ( *10^X )signedInt -100…1000
Kalibrierung 1signedInt -32768…327676446
Kalibrierung 1 ExponentsignedInt -100…100-5
Kalibrierung 2signedInt -32768…327670
Kalibrierung 2 ExponentsignedInt -100…1000
Differential gaps send/limits W/m2signedInt 0…180010
Schaltdifferenz Senden/Grenzwerte ( * 10^X )signedInt -100…1000
Controller global radiationlist0
Locking objectlistlocked if 1
Actuating value by ascending actual valuelistdecreasing
ControllerlistSteady PI controller
Setpoint W/m2signedInt 0…1800800
Sollwert ( *10^X )signedInt -100…1000
Proportional range W/m2signedInt 0…1800100
Differential gap Controller W/m2signedInt 0…1800100
Proportionalbereich Exponent ( *10^X )signedInt -100…1000
Schaltdifferenz Regler ( *10^X )signedInt -100…1000
Proportionalbereich ( *10^X )signedInt -100…1000
Reset time ( in minutes )unsignedInt 0…255150
Actuating value send cyclicallistno
Actuating value distance to limit in %unsignedInt 0…500
Duty cycle in %unsignedInt 0…500
Cycle duration in secondsunsignedInt 0…6553560

Version history

ApplicationApp noFingerprintFirst seenSizeFile
SK08-GLBS 1.5 latest$0026002D2026-11-2570 KBDownload

About this file

This is the official ETS product database for the Arcus-eds S8-GLBS (30804XXX), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Arcus-eds

All Arcus-eds products