S8-GLBS 30804XXX
Arcus-eds · Order number 30804XXX · Arc_S8
Download .knxprod SK08-GLBS 1.5 · 70 KB
Product
| Manufacturer | Arcus-eds |
|---|---|
| Product name | S8-GLBS |
| Order number | 30804XXX |
| Hardware | S8-GLBS |
| Medium | Twisted Pair |
| Rail mounted | No |
| Registration | Certified · 2011-12-07 |
| Languages | en-US, de-DE |
| Catalog entry | M-0076_H-30804XXX-0_HP-0026-15-002D_CI-30804XXX-1 |
| Fingerprint | 002D |
| SHA-256 | ced021b696553a045c7d3ed08dec51f034a99a16173a3e294034a217d690d19e |
| First seen | 2026-11-25 |
| Markets | 18 markets |
Application program: SK08-GLBS 1.5
| Application number | $0026 |
|---|---|
| Version | 1.5 |
| Mask version | MV-0701 (7.1) |
| KNX Data Secure | No |
| Minimum ETS version | 3.0d |
| Parameters | 39 |
| Group objects | 65 |
Group objects (65)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Output, error code | Error code | 4 Bytes | CRWU | |
| 1 | Input, calibration | Calibration value | 4 Bytes | CRWU | |
| 2 | Output, measured value W/m2 | Measured value | 2 Bytes | 7.1 pulses | CRT |
| 2 | Output, measured value W/m2 | Measured value | 2 Bytes | 9.1 temperature (°C) | CRT |
| 2 | Output, measured value W/m2 | Measured value | 4 Bytes | 14.56 power (W) | CRT |
| 3 | Input, auxiliary object W/m2 | Auxiliary object | 2 Bytes | 7.1 pulses | CRWU |
| 3 | Input, auxiliary object W/m2 | Auxiliary object | 2 Bytes | 9.1 temperature (°C) | CRWU |
| 3 | Input, auxiliary object W/m2 | Auxiliary object | 4 Bytes | 14.56 power (W) | CRWU |
| 4 | Output, upper limit W/m2 | Exceeding limit | 1 Bit | 1.2 boolean | CRT |
| 5 | Output, lower limit W/m2 | Undercut limit | 1 Bit | 1.2 boolean | CRT |
| 6 | Output, controller W/m2 | Actuating value | 1 Bit | 1.1 switch | CRT |
| 6 | Output, controller W/m2 | Actuating value | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 7 | Input, enable/lock controller | Enable/lock | 1 Bit | 1.1 switch | CRWU |
| 8 | Output, status object W/m2 | Status | 1 Byte | CRT | |
| 9 | Object 10 | Nicht Verwendet | 4 Bytes | 14.5 amplitude | CRT |
| 10 | Object 11 | Nicht Verwendet | 4 Bytes | 14.5 amplitude | CRT |
| 11 | Object 12 | Nicht Verwendet | 1 Bit | 1.1 switch | CRT |
| 12 | Object 13 | Nicht Verwendet | 1 Bit | 1.1 switch | CRT |
| 13 | Object 14 | Nicht Verwendet | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 14 | Object 15 | Nicht Verwendet | 1 Bit | 1.1 switch | CRWU |
| 15 | Object 16 | Nicht Verwendet | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 16 | Object 17 | Nicht Verwendet | 4 Bytes | 14.5 amplitude | CRT |
| 17 | Object 18 | Nicht Verwendet | 4 Bytes | 14.5 amplitude | CRT |
| 18 | Object 19 | Nicht Verwendet | 1 Bit | 1.1 switch | CRT |
| 19 | Object 20 | Nicht Verwendet | 1 Bit | 1.1 switch | CRT |
| 20 | Object 21 | Nicht Verwendet | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 21 | Object 22 | Nicht Verwendet | 1 Bit | 1.1 switch | CRWU |
| 22 | Object 23 | Nicht Verwendet | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 23 | Object 24 | Nicht Verwendet | 4 Bytes | 14.5 amplitude | CRT |
| 24 | Object 25 | Nicht Verwendet | 4 Bytes | 14.5 amplitude | CRT |
| 25 | Object 26 | Nicht Verwendet | 1 Bit | 1.1 switch | CRT |
| 26 | Object 27 | Nicht Verwendet | 1 Bit | 1.1 switch | CRT |
| 27 | Object 28 | Nicht Verwendet | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 28 | Object 29 | Nicht Verwendet | 1 Bit | 1.1 switch | CRWU |
| 29 | Object 30 | Nicht Verwendet | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 30 | Object 31 | Nicht Verwendet | 4 Bytes | 14.5 amplitude | CRT |
| 31 | Object 32 | Nicht Verwendet | 4 Bytes | 14.5 amplitude | CRT |
| 32 | Object 33 | Nicht Verwendet | 1 Bit | 1.1 switch | CRT |
| 33 | Object 34 | Nicht Verwendet | 1 Bit | 1.1 switch | CRT |
| 34 | Object 35 | Nicht Verwendet | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 35 | Object 36 | Nicht Verwendet | 1 Bit | 1.1 switch | CRWU |
| 36 | Object 37 | Nicht Verwendet | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 37 | Object 38 | Nicht Verwendet | 4 Bytes | 14.5 amplitude | CRT |
| 38 | Object 39 | Nicht Verwendet | 4 Bytes | 14.5 amplitude | CRT |
| 39 | Object 40 | Nicht Verwendet | 1 Bit | 1.1 switch | CRT |
| 40 | Object 41 | Nicht Verwendet | 1 Bit | 1.1 switch | CRT |
| 41 | Object 42 | Nicht Verwendet | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 42 | Object 43 | Nicht Verwendet | 1 Bit | 1.1 switch | CRWU |
| 43 | Object 44 | Nicht Verwendet | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 44 | Object 45 | Nicht Verwendet | 4 Bytes | 14.5 amplitude | CRT |
| 45 | Object 46 | Nicht Verwendet | 4 Bytes | 14.5 amplitude | CRT |
| 46 | Object 47 | Nicht Verwendet | 1 Bit | 1.1 switch | CRT |
| 47 | Object 48 | Nicht Verwendet | 1 Bit | 1.1 switch | CRT |
| 48 | Object 49 | Nicht Verwendet | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 49 | Object 50 | Nicht Verwendet | 1 Bit | 1.1 switch | CRWU |
| 50 | Object 51 | Nicht Verwendet | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 51 | Object 52 | Nicht Verwendet | 4 Bytes | 14.5 amplitude | CRT |
| 52 | Object 53 | Nicht Verwendet | 4 Bytes | 14.5 amplitude | CRT |
| 53 | Object 54 | Nicht Verwendet | 1 Bit | 1.1 switch | CRT |
| 54 | Object 55 | Nicht Verwendet | 1 Bit | 1.1 switch | CRT |
| 55 | Object 56 | Nicht Verwendet | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 56 | Object 57 | Nicht Verwendet | 1 Bit | 1.1 switch | CRWU |
| 57 | Object 58 | Nicht Verwendet | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 58 | Equipment time | Time | 3 Bytes | 10.1 time of day | CRWU |
| 59 | Equipment date | Date | 3 Bytes | 11.1 date | CRWU |
Parameters (39)
| Parameter | Type | Default |
|---|---|---|
| General settings | list | 0 |
| Measured value send cycle period | list | 1 min |
| Actuating value send cycle period ( Seconds ) | unsignedInt 10…250 | 60 |
| Kalibrierungszeit in Tagen | unsignedInt 0…255 | 90 |
| Use clock timer | list | no |
| Timer from | unsignedInt 0…24 | 0 |
| Timer until | unsignedInt 0…24 | 24 |
| Measured value global radiation | list | 0 |
| Measured value send cyclical | list | no |
| Measured value send by change | list | no |
| Value type | list | 2byte float |
| Auxiliary object is | list | Setpoint |
| Auxiliary value store by change | list | no |
| Lower limit W/m2 | signedInt 0…1800 | 400 |
| Unterer Grenzwert ( *10^X ) | signedInt -100…100 | 0 |
| Upper limit W/m2 | signedInt 0…1800 | 1000 |
| Oberer Grenzwert ( *10^X ) | signedInt -100…100 | 0 |
| Kalibrierung 1 | signedInt -32768…32767 | 6446 |
| Kalibrierung 1 Exponent | signedInt -100…100 | -5 |
| Kalibrierung 2 | signedInt -32768…32767 | 0 |
| Kalibrierung 2 Exponent | signedInt -100…100 | 0 |
| Differential gaps send/limits W/m2 | signedInt 0…1800 | 10 |
| Schaltdifferenz Senden/Grenzwerte ( * 10^X ) | signedInt -100…100 | 0 |
| Controller global radiation | list | 0 |
| Locking object | list | locked if 1 |
| Actuating value by ascending actual value | list | decreasing |
| Controller | list | Steady PI controller |
| Setpoint W/m2 | signedInt 0…1800 | 800 |
| Sollwert ( *10^X ) | signedInt -100…100 | 0 |
| Proportional range W/m2 | signedInt 0…1800 | 100 |
| Differential gap Controller W/m2 | signedInt 0…1800 | 100 |
| Proportionalbereich Exponent ( *10^X ) | signedInt -100…100 | 0 |
| Schaltdifferenz Regler ( *10^X ) | signedInt -100…100 | 0 |
| Proportionalbereich ( *10^X ) | signedInt -100…100 | 0 |
| Reset time ( in minutes ) | unsignedInt 0…255 | 150 |
| Actuating value send cyclical | list | no |
| Actuating value distance to limit in % | unsignedInt 0…50 | 0 |
| Duty cycle in % | unsignedInt 0…50 | 0 |
| Cycle duration in seconds | unsignedInt 0…65535 | 60 |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| SK08-GLBS 1.5 latest | $0026 | 002D | 2026-11-25 | 70 KB | Download |
About this file
This is the official ETS product database for the Arcus-eds S8-GLBS (30804XXX), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from Arcus-eds
- S8-T8 30801XXX
- S8-WAQ 30802XXX
- S8-CO2 30803XXX
- S8-BFT 3080500X
- S8-BFTLFT 3080502X
- S8-AN2 30806XXX
- S8-F 30807XXX
- S8-UNI 3080XXXX
- SK80_F 1180440001
- Touch_IT-Plugin 22310xxx
- Sensor Temperature IP65 30101xxx
- Sensor Temperature SK03 30103xxx