KNX Database

S8-BFT 3080500X

Arcus-eds · Order number 3080500X · Arc_S8

Download .knxprod SK08-BFT 1.5 · 73 KB

Product

ManufacturerArcus-eds
Product nameS8-BFT
Order number3080500X
HardwareS8-BFT
MediumTwisted Pair
Rail mountedNo
RegistrationCertified · 2011-12-07
Languagesen-US, de-DE
Catalog entryM-0076_H-3080500X-0_HP-0027-15-68F0_CI-3080500X-1
Fingerprint68F0
SHA-2562733910387e876b54f53545382b2ec1dfd20e3f73a705338968c57541166baa4
First seen2026-11-25
Markets18 markets

Application program: SK08-BFT 1.5

Application number$0027
Version1.5
Mask versionMV-0701 (7.1)
KNX Data SecureNo
Minimum ETS version3.0d
Parameters69
Group objects70
Group objects (70)
NoNameFunctionSizeDPTFlags
0Output, Error codeError code4 BytesCRT
1Input, CalibrationCalibrationvalue4 BytesCRWU
2Output, measured value soil moistureMeasured value2 Bytes9.1 temperature (°C)CRT
2Output, measured value soil moistureMeasured value4 Bytes14.5 amplitudeCRT
3Input, auxiliary object soil moistureAuxiliary object2 Bytes9.1 temperature (°C)CRWU
3Input, auxiliary object soil moistureAuxiliary object4 Bytes14.5 amplitudeCRWU
4Output, upper limit soil moistureExceeding limit1 Bit1.2 booleanCRT
5Output, lower limit soil moistureUndercut limit1 Bit1.2 booleanCRT
6Output, controller soil moistureActuating value1 Bit1.1 switchCRT
6Output, controller soil moistureActuating value1 Byte5.10 counter pulses (0..255)CRT
7Input, enable/lock controllerEnable/lock1 Bit1.1 switchCRWU
8Output, status object soil moistureStatus1 ByteCRT
9Output, soil temperatureMeasured value4 Bytes14.68 temperature (°C)CRT
9Output, soil temperatureMeasured value1 Byte6.10 counter pulses (-128..127)CRT
9Output, soil temperatureMeasured value2 Bytes8.1 pulses differenceCRT
9Output, soil temperatureMeasured value2 Bytes9.1 temperature (°C)CRT
10Input, auxiliary object soil temperatureAuxiliary object4 Bytes14.68 temperature (°C)CRWU
10Input, auxiliary object soil temperatureAuxiliary object1 Byte6.10 counter pulses (-128..127)CRWU
10Input, auxiliary object soil temperatureAuxiliary object2 Bytes8.1 pulses differenceCRWU
10Input, auxiliary object soil temperatureAuxiliary object2 Bytes9.1 temperature (°C)CRWU
11Output, upper limit soil temperatureLimit1 Bit1.2 booleanCRT
12Output, lower limit soil temperatureLimit1 Bit1.2 booleanCRT
13Output, controller soil temperatureActuating value1 Bit1.1 switchCRT
13Output, controller soil temperatureActuating value1 Byte5.10 counter pulses (0..255)CRT
14Input, enable/lock soil temperatureEnable/lock1 Bit1.1 switchCRWU
15Output, status object soil temperatureChannel status1 ByteCRT
16Output, Measuard Value C3Measured value4 Bytes14.5 amplitudeCRT
17Input, Auxiliary object C3Auxiliary object4 Bytes14.5 amplitudeCRWU
18Output, runtime upper limitExceeding limit1 Bit1.2 booleanCRT
19Output, runtime lower limitUndercut limit1 Bit1.2 booleanCRT
20Output, Controller C3Actuating value1 Byte5.10 counter pulses (0..255)CRT
21Input, Enable/lock C3Enable/lock1 Bit1.1 switchCRWU
22Output, object status C3Channel status1 ByteCRT
23Output, measured value soil temperatureMeasured value4 Bytes14.68 temperature (°C)CRT
24Input, Auxiliary object C4Auxiliary object2 Bytes9.1 temperature (°C)CRWU
25Output, upper limit soil temperatureLimit1 Bit1.2 booleanCRT
26Output, lower limit soil temperatureLimit1 Bit1.2 booleanCRT
27Output, Controller C5Actuating value1 Bit1.1 switchCRT
28Input, Enable/lock C5Enable/lock1 Bit1.1 switchCRWU
29Output, Object Status C5Channel status1 ByteCRT
30Output, Measured value C5Measured value4 Bytes14.5 amplitudeCRT
31Input, Auxiliary object C5Auxiliary object1 Bit1.1 switchCRWU
32Output, upper limit C5Limit1 Bit1.2 booleanCRT
33Output, lower limit C5Limit1 Bit1.2 booleanCRT
34Output, Controller C5Actuating value1 Byte5.10 counter pulses (0..255)CRT
35Input, Enable/lock C5Enable/lock1 Bit1.1 switchCRWU
36Output, Object Status C5Channel status1 ByteCRT
37Output, S2Contact S21 Bit1.1 switchCRT
38Input, Auxiliary object C6Auxiliary object1 Bit1.1 switchCRWU
39Output, upper limit C6Limit1 Bit1.2 booleanCRT
40Output, lower limit C6Limit1 Bit1.2 booleanCRT
41Object 42Nicht Verwendet1 Byte5.10 counter pulses (0..255)CRT
42Object 43Nicht Verwendet1 Bit1.1 switchCRWU
43Object 44Nicht Verwendet1 Byte5.10 counter pulses (0..255)CRT
44Object 45Nicht Verwendet4 Bytes12.1 counter pulses (unsigned)CRT
45Object 46Nicht Verwendet4 Bytes12.1 counter pulses (unsigned)CRT
46Object 47Nicht Verwendet1 Bit1.1 switchCRT
47Object 48Nicht Verwendet1 Bit1.1 switchCRT
48Object 49Nicht Verwendet1 Byte5.10 counter pulses (0..255)CRT
49Object 50Nicht Verwendet1 Bit1.1 switchCRWU
50Object 51Nicht Verwendet1 Byte5.10 counter pulses (0..255)CRT
51Object 52Nicht Verwendet4 Bytes12.1 counter pulses (unsigned)CRT
52Object 53Nicht Verwendet4 Bytes12.1 counter pulses (unsigned)CRT
53Object 54Nicht Verwendet1 Bit1.1 switchCRT
54Object 55Nicht Verwendet1 Bit1.1 switchCRT
55Object 56Nicht Verwendet1 Byte5.10 counter pulses (0..255)CRT
56Object 57Nicht Verwendet1 Bit1.1 switchCRWU
57Object 58Nicht Verwendet1 Byte5.10 counter pulses (0..255)CRT
58TimeTime3 Bytes10.1 time of dayCRWU
59DateDate3 Bytes11.1 dateCRWU
Parameters (57)
ParameterTypeDefault
General settingslist0
Measured value send cycle periodlist1 Min
Actuating value send cycle period ( Seconds )unsignedInt 10…25060
Kalibrierungszeit in TagenunsignedInt 0…25590
Use clock timerlistNo
Timer fromunsignedInt 0…240
Timer untilunsignedInt 0…2424
Measured value soil moisturelist0
Measured value send cyclicallistNo
Measured value send by changelistNo
Type datapointlist2byte float
Auxiliary object islistSetpoint
Auxiliary value store by changelistNo
Lower limit ( hPa )signedInt 0…1400100
Unterer Grenzwert ( *10^X )signedInt -100…1002
Upper limit ( hPa )signedInt 0…1400600
Oberer Grenzwert ( *10^X )signedInt -100…1002
Kalibrierung 1signedInt -32768…327671
Kalibrierung 1 ExponentsignedInt -100…1000
Kalibrierung 2signedInt -32768…327670
Kalibrierung 2 ExponentsignedInt -100…1000
Differential gap send/limits x 0,01signedInt 0…140050
Schaltdifferenz Senden/Grenzwerte ( * 10^X )signedInt -100…1002
Controller soil moisturelist0
Locking objectlistlocked if 1
Actuating value by ascending actual valuelistdecreasing
ControllerlistTwo-Position Controller Pulsed
Setpoint ( hPa )signedInt 0…1400300
Sollwert ( *10^X )signedInt -100…1002
Proportional range ( hPa )signedInt 0…1400100
Differential gap Controller ( hPa )signedInt 0…1400100
Proportionalbereich Exponent ( *10^X )signedInt -100…1002
Schaltdifferenz Regler ( *10^X )signedInt -100…1002
Proportionalbereich ( *10^X )signedInt -100…1002
Reset time ( in minutes )unsignedInt 0…255150
Actuating value send cyclicallistNo
Actuating value distance to limit in %unsignedInt 0…500
Duty cycle in %unsignedInt 0…500
Cycle duration in secondsunsignedInt 0…6553560
Measured value soil temperaturelist0
Lower limit ( x 0,01 °C)signedInt -9999…9999700
Unterer Grenzwert ( *10^X )signedInt -100…100-2
Upper limit ( x 0,01 °C)signedInt -9999…99991700
Oberer Grenzwert ( *10^X )signedInt -100…100-2
Kalibrierung 1 ExponentsignedInt -100…100-2
Measured value shift ( x 0,01 °C)signedInt -32768…327670
Kalibrierung 2 ExponentsignedInt -100…100-2
Differential gap send/limits ( x 0,01 °C)signedInt -9999…999950
Schaltdifferenz Senden/Grenzwerte ( * 10^X )signedInt -100…100-2
Controller soil temperaturelist0
ControllerlistSteady PI controller
Setpoint ( x 0,01 °C)signedInt -9999…99991800
Sollwert ( *10^X )signedInt -100…100-2
Differential gap Controller ( °C )signedInt -9999…99995
Proportional range ( °C )signedInt -9999…99995
Proportionalbereich Exponent ( *10^X )signedInt -100…1000
Schaltdifferenz Regler ( *10^X )signedInt -100…1000

Version history

ApplicationApp noFingerprintFirst seenSizeFile
SK08-BFT 1.5 latest$002768F02026-11-2573 KBDownload

About this file

This is the official ETS product database for the Arcus-eds S8-BFT (3080500X), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Arcus-eds

All Arcus-eds products