S8-CO2 30803XXX

Arcus-eds · Order number 30803XXX · Arc_S8

Download .knxprod SK08-CO2 1.5 · 78 KB

Product

ManufacturerArcus-eds
Product nameS8-CO2
Order number30803XXX
HardwareS8-CO2
MediumTwisted Pair
Rail mountedNo
RegistrationCertified · 2011-12-07
Languagesen-US, de-DE
Catalog entryM-0076_H-30803XXX-0_HP-0025-15-0DA9_CI-30803XXX-1
Fingerprint0DA9
SHA-25681495568a660b1e359f0da4ece3905f7870b87dc14180fb67f542eac2b0cf65c
First seen2026-11-25
Markets18 markets

Application program: SK08-CO2 1.5

Application number$0025
Version1.5
Mask versionMV-0701 (7.1)
KNX Data SecureNo
Minimum ETS version3.0d
Parameters133
Group objects113
Group objects (113)
NoNameFunctionSizeDPTFlags
0Output, error codeError code4 BytesCRWU
1Input, calibrationCalibration value4 BytesCRWU
2Output, measured value CO2Measured value2 Bytes7.1 pulsesCRT
2Output, measured value CO2Measured value2 Bytes9.1 temperature (°C)CRT
2Output, measured value CO2Measured value4 Bytes14.5 amplitudeCRT
3Input, auxiliary object C1Hilfsgröße2 Bytes7.1 pulsesCRWU
3Input, auxiliary object CO2Auxiliary object2 Bytes9.1 temperature (°C)CRWU
3Input, auxiliary object CO2Auxiliary object4 Bytes14.5 amplitudeCRWU
4Output, upper limit CO2Exceeding limit1 Bit1.2 booleanCRT
5Output, lower limit CO2Undercut limit1 Bit1.2 booleanCRT
6Output, controller CO2Actuating value1 Bit1.1 switchCRT
6Output, controller CO2Actuating value1 Byte5.10 counter pulses (0..255)CRT
7Input, enable/lock controllerEnable/lock 1 Bit1.1 switchCRWU
8Output, object status CO2Status1 ByteCRT
9Object 10Nicht Verwendet4 Bytes14.5 amplitudeCRT
10Object 11Nicht Verwendet4 Bytes14.5 amplitudeCRT
11Object 12Nicht Verwendet1 Bit1.1 switchCRT
12Object 13Nicht Verwendet1 Bit1.1 switchCRT
13Object 14Nicht Verwendet1 Byte5.10 counter pulses (0..255)CRT
14Object 15Nicht Verwendet1 Bit1.1 switchCRWU
15Object 16Nicht Verwendet1 Byte5.10 counter pulses (0..255)CRT
16Object 17Nicht Verwendet4 Bytes14.5 amplitudeCRT
17Object 18Nicht Verwendet4 Bytes14.5 amplitudeCRT
18Object 19Nicht Verwendet1 Bit1.1 switchCRT
19Object 20Nicht Verwendet1 Bit1.1 switchCRT
20Object 21Nicht Verwendet1 Byte5.10 counter pulses (0..255)CRT
21Object 22Nicht Verwendet1 Bit1.1 switchCRWU
22Object 23Nicht Verwendet1 Byte5.10 counter pulses (0..255)CRT
23Object 24Nicht Verwendet4 Bytes14.5 amplitudeCRT
24Object 25Nicht Verwendet4 Bytes14.5 amplitudeCRT
25Object 26Nicht Verwendet1 Bit1.1 switchCRT
26Object 27Nicht Verwendet1 Bit1.1 switchCRT
27Object 28Nicht Verwendet1 Byte5.10 counter pulses (0..255)CRT
28Object 29Nicht Verwendet1 Bit1.1 switchCRWU
29Object 30Nicht Verwendet1 Byte5.10 counter pulses (0..255)CRT
30Output, measured value dewpoint temperatureCalculated value1 Byte6.10 counter pulses (-128..127)CRT
30Output, measured value dewpoint temperatureCalculated value2 Bytes8.1 pulses differenceCRT
30Output, measured value dewpoint temperatureCalculated value2 Bytes9.1 temperature (°C)CRT
30Output, measured value dewpoint temperatureCalculated value4 Bytes14.68 temperature (°C)CRT
30Object 31Nicht Verwendet4 Bytes14.5 amplitudeCRT
31Input, auxiliary object dewpoint temperatureAuxiliary object2 Bytes8.1 pulses differenceCRWU
31Input, auxiliary object dewpoint temperatureAuxiliary object1 Byte6.10 counter pulses (-128..127)CRWU
31Input, auxiliary object dewpoint temperatureAuxiliary object2 Bytes9.1 temperature (°C)CRWU
31Input, auxiliary object dewpoint temperatureAuxiliary object4 Bytes14.68 temperature (°C)CRWU
31Object 32Nicht Verwendet4 Bytes14.5 amplitudeCRT
32Output, upper limit dewpoint temperatureLimit1 Bit1.1 switchCRT
32Object 33Limit1 Bit1.1 switchCRT
33Output, lower limit dewpoint temperatureLimit1 Bit1.1 switchCRT
33Object 34Limit1 Bit1.1 switchCRT
34Object 35Nicht Verwendet1 Byte5.10 counter pulses (0..255)CRT
35Object 36Nicht Verwendet1 Bit1.1 switchCRWU
36Object 37Nicht Verwendet1 Byte5.10 counter pulses (0..255)CRT
37Output, measured value absolute humidityCalculated value1 Byte5.10 counter pulses (0..255)CRT
37Output, measured value absolute humidityCalculated value2 Bytes7.1 pulsesCRT
37Output, measured value absolute humidityCalculated value2 Bytes9.1 temperature (°C)CRT
37Output, measured value absolute humidityCalculated value4 Bytes14.5 amplitudeCRT
37Object 38Nicht Verwendet4 Bytes14.5 amplitudeCRT
38Input, auxiliary object absolute humidityAuxiliary object2 Bytes7.1 pulsesCRWU
38Input, auxiliary object absolute humidityAuxiliary object1 Byte5.10 counter pulses (0..255)CRWU
38Input, auxiliary object absolute humidityAuxiliary object2 Bytes9.1 temperature (°C)CRWU
38Input, auxiliary object absolute humidityAuxiliary object4 Bytes14.5 amplitudeCRWU
38Object 39Nicht Verwendet4 Bytes14.5 amplitudeCRWU
39Output, upper limit absolute humidityLimit1 Bit1.1 switchCRT
39Object 40Limit1 Bit1.1 switchCRT
40Output, lower limit absolute humidityLimit1 Bit1.1 switchCRT
40Object 41Limit1 Bit1.1 switchCRT
41Object 42Nicht Verwendet1 Byte5.10 counter pulses (0..255)CRT
42Object 43Nicht Verwendet1 Bit1.1 switchCRWU
43Object 44Nicht Verwendet1 Byte5.10 counter pulses (0..255)CRT
44Output, measured value relative humidityMeasured value1 Byte6.10 counter pulses (-128..127)CRT
44Output, measured value relative humidityMeasured value 2 Bytes8.1 pulses differenceCRT
44Output, measured value relative humidityMeasured value 2 Bytes9.1 temperature (°C)CRT
44Object 45Nicht Verwendet4 Bytes14.5 amplitudeCRT
44Output, measured value relative humidityMeasured value 4 Bytes14.5 amplitudeCRT
45Input, auxiliary object relative humidityAuxiliary object 2 Bytes8.1 pulses differenceCRWU
45Input, auxiliary object relative humidityAuxiliary object 1 Byte6.10 counter pulses (-128..127)CRWU
45Input, auxiliary object relative humidityAuxiliary object 2 Bytes9.1 temperature (°C)CRWU
45Object 46Nicht Verwendet4 Bytes14.5 amplitudeCRWU
45Input, auxiliary object relative humidityAuxiliary object4 Bytes14.5 amplitudeCRWU
46Output, upper limit relative humidityLimit1 Bit1.1 switchCRT
46Object 47Limit1 Bit1.1 switchCRT
47Output, lower limit relative humidityLimit1 Bit1.1 switchCRT
47Object 48Limit1 Bit1.1 switchCRT
48Output, controller relative humidityActuating value1 Bit1.1 switchCRT
48Output, controller relative humidityActuating value1 Byte5.10 counter pulses (0..255)CRT
48Object 49Actuating value1 Byte5.10 counter pulses (0..255)CRT
49Input, enable/lock relative humidityEnable/lock1 Bit1.1 switchCRWU
49Object 50Enable/lock1 Bit1.1 switchCRWU
50Output, Object status relative humidityChannel status1 ByteCRT
50Object 51Channel status1 ByteCRT
51Output, measured value air temperatureMeasured value1 Byte6.10 counter pulses (-128..127)CRT
51Output, measured value air temperatureMeasured value2 Bytes8.1 pulses differenceCRT
51Output, measured value air temperatureMeasured value2 Bytes9.1 temperature (°C)CRT
51Object 52Nicht Verwendet4 Bytes14.5 amplitudeCRT
51Output, measured value air temperatureMeasured value 4 Bytes14.68 temperature (°C)CRT
52Input, auxiliary object air temperatureAuxiliary object2 Bytes8.1 pulses differenceCRWU
52Input, auxiliary object air temperatureAuxiliary object1 Byte6.10 counter pulses (-128..127)CRWU
52Input, auxiliary object air temperatureAuxiliary object2 Bytes9.1 temperature (°C)CRWU
52Object 53Nicht Verwendet4 Bytes14.5 amplitudeCRT
52Input, auxiliary object air temperatureAuxiliary object 4 Bytes14.68 temperature (°C)CRWU
53Output, upper limit air temperatureLimit1 Bit1.1 switchCRT
53Object 54Limit1 Bit1.1 switchCRT
54Output, lower limit air temperatureLimit1 Bit1.1 switchCRT
54Object 55Limit1 Bit1.1 switchCRT
55Output, controller K8Actuating value1 Bit1.1 switchCRT
55Output, controller K8Actuating value1 Byte5.10 counter pulses (0..255)CRT
55Object 56Actuating value1 Byte5.10 counter pulses (0..255)CRT
56Input, enable/lock air temperatureEnable/lock1 Bit1.1 switchCRWU
56Object 57Enable/lock1 Bit1.1 switchCRWU
57Output, Object status air temperatureChannel status1 ByteCRT
57Object 58Channel status1 ByteCRT
58Equipment timeTime3 Bytes10.1 time of dayCRWU
59Equipment dateDate3 Bytes11.1 dateCRWU
Parameters (78)
ParameterTypeDefault
Global settingslist0
Measured value send cycle periodlist1 min
Actuating value send cycle period ( Seconds )unsignedInt 10…25060
Kalibrierungszeit in TagenunsignedInt 0…25590
Use clock timerlistno
Timer fromunsignedInt 0…240
Timer untilunsignedInt 0…2424
Measured values CO2list0
Measured value send cyclicallistno
Measured value send by changelistno
Type datapointlist2byte float
Auxiliary object islistSetpoint
Auxiliary value store by changelistno
Lower limit ppmsignedInt 0…4999400
Unterer Grenzwert ( *10^X )signedInt -100…1000
Upper limit ppmsignedInt 0…49991000
Oberer Grenzwert ( *10^X )signedInt -100…1000
Kalibrierung 1signedInt -32768…327671
Kalibrierung 1 ExponentsignedInt -100…1000
Kalibrierung 2signedInt -32768…327670
Kalibrierung 2 ExponentsignedInt -100…1000
Differential gaps send/limits ppmsignedInt 0…499910
Schaltdifferenz Senden/Grenzwerte ( * 10^X )signedInt -100…1000
Controller CO2list0
Locking objectlistlocked if 1
Actuating value by ascending actual valuelistincreasing
ControllerlistSteady PI controller
Setpoint ppmsignedInt 0…4999800
Sollwert ( *10^X )signedInt -100…1000
Proportional range ppmsignedInt 0…4999100
Differential gap Controller ppmsignedInt 0…4999100
Proportionalbereich Exponent ( *10^X )signedInt -100…1000
Schaltdifferenz Regler ( *10^X )signedInt -100…1000
Proportionalbereich ( *10^X )signedInt -100…1000
Reset time ( in minutes )unsignedInt 0…255150
Actuating value send cyclicallistno
Actuating value distance to limit in %unsignedInt 0…500
Duty cycle in %unsignedInt 0…500
Cycle duration in secondsunsignedInt 0…6553560
Dewpoint temperaturelist0
Auxiliary object islistUpper limit
Auxiliary value store by changelistno
Lower limit ( x 0,01 °C)signedInt -9999…199990
Unterer Grenzwert ( *10^X )signedInt -100…100-2
Upper limit ( x 0,01 °C)signedInt -9999…199991500
Oberer Grenzwert ( *10^X )signedInt -100…100-2
Kalibrierung 1 ExponentsignedInt -100…100-2
Messwertverschiebung ( x 0,01 °C)signedInt -32768…327670
Kalibrierung 2 ExponentsignedInt -100…100-2
Differential gap send/limits ( x 0,01 °C)signedInt -9999…1999950
Schaltdifferenz Senden/Grenzwerte ( * 10^X )signedInt -100…100-2
Absolute humiditylist0
Lower limit ( x 0,01 g/m^3)signedInt -9999…19999700
Upper limit ( x 0,01 g/m^3 )signedInt -9999…199991700
Messwertverschiebung ( x 0,01 g/m^3 )signedInt -32768…327670
Differential gap send/limits ( x 0,01 g/m^3 )signedInt -9999…1999950
Humiditylist0
Wertetyplist2byte float
Lower limit ( % )signedInt 0…10030
Upper limit ( %)signedInt 0…10080
Differential gap send/limits ( % )signedInt 0…1005
Schaltdifferenz Senden/Grenzwerte ( in % )signedInt -100…1000
Controller humiditylist0
Actuating value by ascending actual valuelistdecreasing
Setpoint ( % )signedInt 0…10050
Differential gap Controller ( % )signedInt 0…1005
Proportional range ( % )signedInt 0…1005
Actuating value distance to limit in %unsignedInt 0…500
Zeitschaltuhr verwendenlistno
Air temperaturelist0
Lower limit ( x 0,01 °C)signedInt -9999…19999700
Upper limit ( x 0,01 °C)signedInt -9999…199991700
Measured value shift ( x 0,01 °C)signedInt -32768…327670
Controller air temperaturelist0
Setpoint ( x 0,01 °C)signedInt -9999…199991800
Sollwert ( *10^X )signedInt -100…100-2
Differential gap Controller ( in °C)signedInt -9999…199995
Proportional range ( in °C)signedInt -9999…199995

Version history

ApplicationApp noFingerprintFirst seenSizeFile
SK08-CO2 1.5 latest$00250DA92026-11-2578 KBDownload

About this file

This is the official ETS product database for the Arcus-eds S8-CO2 (30803XXX), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Arcus-eds

All Arcus-eds products