Controller / Sensor 6-fold AP SCN-RT6AP.01
MDT technologies GmbH · Order number SCN-RT6AP.01 · Temperature Controller › 6 Channel Temperature Controller
6 Channel Temperature Controller
Download .knxprod Temperature controller 6 fold AP 1.3 · 171 KB
Product
| Manufacturer | MDT technologies GmbH |
|---|---|
| Product name | Controller / Sensor 6-fold AP |
| Order number | SCN-RT6AP.01 |
| Product text | Temperature controller / sensor 6-fold AP |
| Hardware | Temperaturregler / -sensor 6-fach |
| Medium | Twisted Pair |
| Bus current (mA) | 5 |
| Rail mounted | No |
| Registration | Certified |
| Languages | de-DE, en-US, es-ES, fr-FR |
| Catalog entry | M-0083_H-70-1_HP-0043-13-34C2_CI-SCN.2DRT6AP.2E01-1 |
| Fingerprint | 34C2 |
| SHA-256 | 2fc2c60f9d689c746eaaedafb4d6592234e33671dcc7ed25c388fc566bf0c5b5 |
| First seen | 2026-11-25 |
| Markets | 69 markets |
Application program: Temperature controller 6 fold AP 1.3
| Application number | $0043 |
|---|---|
| Version | 1.3 |
| Mask version | MV-0701 (7.1) |
| KNX Data Secure | No |
| Minimum ETS version | 4.0 |
| Parameters | 715 |
| Group objects | 245 |
Group objects (245)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Channel 1 | Actual temperature value | 2 Bytes | 9.1 temperature (°C) | CRT |
| 1 | Channel 1 | Higher message value | 1 Bit | CRT | |
| 2 | Channel 1 | Below message value | 1 Bit | CRT | |
| 3 | Channel 1 | Frost alarm | 1 Bit | CRT | |
| 4 | Channel 1 | Heat alarm | 1 Bit | CRT | |
| 5 | Channel 1 | External sensor | 2 Bytes | 9.1 temperature (°C) | CW |
| 6 | Channel 1 | Setpoint comfort | 2 Bytes | 9.1 temperature (°C) | CRWT |
| 7 | Channel 1 | Set point value offset | 2 Bytes | 9.2 temperature difference (K) | CWT |
| 7 | Channel 1 | Set point value offset | 2 Bytes | 9.2 temperature difference (K) | CW |
| 8 | Channel 1 | Control value heating | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 8 | Channel 1 | Control value heating | 1 Bit | CRT | |
| 9 | Channel 1 | Control value cooling | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 9 | Channel 1 | Control value cooling | 1 Bit | CRT | |
| 9 | Channel 1 | Status: 0=Cool 1=Heat | 1 Bit | CRT | |
| 10 | Channel 1 | Mode comfort | 1 Bit | 1.1 switch | CW |
| 11 | Channel 1 | Mode night | 1 Bit | 1.1 switch | CW |
| 12 | Channel 1 | Mode frost protection | 1 Bit | 1.1 switch | CW |
| 12 | Channel 1 | Mode heat protection | 1 Bit | 1.1 switch | CW |
| 12 | Channel 1 | Mode frost/heat protection | 1 Bit | 1.1 switch | CW |
| 13 | Channel 1 | Heating disable object | 1 Bit | 1.3 enable | CW |
| 14 | Channel 1 | Cooling disable object | 1 Bit | 1.3 enable | CW |
| 15 | Channel 1 | Heating request | 1 Bit | 1.1 switch | CRT |
| 16 | Channel 1 | Cooling request | 1 Bit | 1.1 switch | CRT |
| 17 | Channel 1 | Heating/cooling switchover | 1 Bit | CWT | |
| 18 | Channel 1 | Max memory value | 2 Bytes | 9.1 temperature (°C) | CRT |
| 19 | Channel 1 | Min memory value | 2 Bytes | 9.1 temperature (°C) | CRT |
| 20 | Channel 1 | Min/max memory reset | 1 Bit | 1.3 enable | CW |
| 21 | Channel 1 | Reset setpoint value | 1 Bit | 1.3 enable | CW |
| 22 | Channel 1 | DPT_HVAC Status | 1 Byte | CRT | |
| 23 | Channel 1 | Error external sensor | 1 Bit | CRT | |
| 24 | Channel 1 | Actual setpoint | 2 Bytes | 9.1 temperature (°C) | CRT |
| 25 | Channel 1 | DPT_RHCC Status | 2 Bytes | CRT | |
| 26 | Channel 1 | Mode selection | 1 Byte | CW | |
| 26 | Channel 1 | Mode selection | 1 Byte | CRWT | |
| 27 | Channel 1 | Set point offset (1=+/0=-) | 1 Bit | CW | |
| 28 | Channel 1 | Flow temperature | 2 Bytes | 9.1 temperature (°C) | CW |
| 29 | 1 Byte | ||||
| 30 | Channel 1 | Error temperature sensor | 1 Bit | CRT | |
| 31 | 1 Byte | ||||
| 32 | 1 Byte | ||||
| 33 | Channel 2 | Actual temperature value | 2 Bytes | 9.1 temperature (°C) | CRT |
| 34 | Channel 2 | Higher message value | 1 Bit | CRT | |
| 35 | Channel 2 | Below message value | 1 Bit | CRT | |
| 36 | Channel 2 | Frost alarm | 1 Bit | CRT | |
| 37 | Channel 2 | Heat alarm | 1 Bit | CRT | |
| 38 | Channel 2 | External sensor | 2 Bytes | 9.1 temperature (°C) | CW |
| 39 | Channel 2 | Setpoint comfort | 2 Bytes | 9.1 temperature (°C) | CRWT |
| 40 | Channel 2 | Set point value offset | 2 Bytes | 9.2 temperature difference (K) | CW |
| 40 | Channel 2 | Set point value offset | 2 Bytes | 9.2 temperature difference (K) | CWT |
| 41 | Channel 2 | Control value heating | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 41 | Channel 2 | Control value heating | 1 Bit | CRT | |
| 42 | Channel 2 | Control value cooling | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 42 | Channel 2 | Control value cooling | 1 Bit | CRT | |
| 42 | Channel 2 | Status: 0=Cool 1=Heat | 1 Bit | CRT | |
| 43 | Channel 2 | Mode comfort | 1 Bit | 1.1 switch | CW |
| 44 | Channel 2 | Mode night | 1 Bit | 1.1 switch | CW |
| 45 | Channel 2 | Mode frost protection | 1 Bit | 1.1 switch | CW |
| 45 | Channel 2 | Mode heat protection | 1 Bit | 1.1 switch | CW |
| 45 | Channel 2 | Mode frost/heat protection | 1 Bit | 1.1 switch | CW |
| 46 | Channel 2 | Heating disable object | 1 Bit | 1.3 enable | CW |
| 47 | Channel 2 | Cooling disable object | 1 Bit | 1.3 enable | CW |
| 48 | Channel 2 | Heating request | 1 Bit | 1.1 switch | CRT |
| 49 | Channel 2 | Cooling request | 1 Bit | 1.1 switch | CRT |
| 50 | Channel 2 | Heating/cooling switchover | 1 Bit | CWT | |
| 51 | Channel 2 | Max memory value | 2 Bytes | 9.1 temperature (°C) | CRT |
| 52 | Channel 2 | Min memory value | 2 Bytes | 9.1 temperature (°C) | CRT |
| 53 | Channel 2 | Min/max memory reset | 1 Bit | 1.3 enable | CW |
| 54 | Channel 2 | Reset setpoint value | 1 Bit | 1.3 enable | CW |
| 55 | Channel 2 | DPT_HVAC Status | 1 Byte | CRT | |
| 56 | Channel 2 | Error external sensor | 1 Bit | CRT | |
| 57 | Channel 2 | Actual setpoint | 2 Bytes | 9.1 temperature (°C) | CRT |
| 58 | Channel 2 | DPT_RHCC Status | 2 Bytes | CRT | |
| 59 | Channel 2 | Mode selection | 1 Byte | CW | |
| 59 | Channel 2 | Mode selection | 1 Byte | CRWT | |
| 60 | Channel 2 | Set point offset (1=+/0=-) | 1 Bit | CW | |
| 61 | Channel 2 | Flow temperature | 2 Bytes | 9.1 temperature (°C) | CW |
| 62 | 1 Byte | ||||
| 63 | Channel 2 | Error temperature sensor | 1 Bit | CRT | |
| 64 | 1 Byte | ||||
| 65 | 1 Byte | ||||
| 66 | Channel 3 | Actual temperature value | 2 Bytes | 9.1 temperature (°C) | CRT |
| 67 | Channel 3 | Higher message value | 1 Bit | CRT | |
| 68 | Channel 3 | Below message value | 1 Bit | CRT | |
| 69 | Channel 3 | Frost alarm | 1 Bit | CRT | |
| 70 | Channel 3 | Heat alarm | 1 Bit | CRT | |
| 71 | Channel 3 | External sensor | 2 Bytes | 9.1 temperature (°C) | CW |
| 72 | Channel 3 | Setpoint comfort | 2 Bytes | 9.1 temperature (°C) | CRWT |
| 73 | Channel 3 | Set point value offset | 2 Bytes | 9.2 temperature difference (K) | CW |
| 73 | Channel 3 | Set point value offset | 2 Bytes | 9.2 temperature difference (K) | CWT |
| 74 | Channel 3 | Control value heating | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 74 | Channel 3 | Control value heating | 1 Bit | CRT | |
| 75 | Channel 3 | Control value cooling | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 75 | Channel 3 | Control value cooling | 1 Bit | CRT | |
| 75 | Channel 3 | Status: 0=Cool 1=Heat | 1 Bit | CRT | |
| 76 | Channel 3 | Mode comfort | 1 Bit | 1.1 switch | CW |
| 77 | Channel 3 | Mode night | 1 Bit | 1.1 switch | CW |
| 78 | Channel 3 | Mode frost protection | 1 Bit | 1.1 switch | CW |
| 78 | Channel 3 | Mode heat protection | 1 Bit | 1.1 switch | CW |
| 78 | Channel 3 | Mode frost/heat protection | 1 Bit | 1.1 switch | CW |
| 79 | Channel 3 | Heating disable object | 1 Bit | 1.3 enable | CW |
| 80 | Channel 3 | Cooling disable object | 1 Bit | 1.3 enable | CW |
| 81 | Channel 3 | Heating request | 1 Bit | 1.1 switch | CRT |
| 82 | Channel 3 | Cooling request | 1 Bit | 1.1 switch | CRT |
| 83 | Channel 3 | Heating/cooling switchover | 1 Bit | CWT | |
| 84 | Channel 3 | Max memory value | 2 Bytes | 9.1 temperature (°C) | CRT |
| 85 | Channel 3 | Min memory value | 2 Bytes | 9.1 temperature (°C) | CRT |
| 86 | Channel 3 | Min/max memory reset | 1 Bit | 1.3 enable | CW |
| 87 | Channel 3 | Reset setpoint value | 1 Bit | 1.3 enable | CW |
| 88 | Channel 3 | DPT_HVAC Status | 1 Byte | CRT | |
| 89 | Channel 3 | Error external sensor | 1 Bit | CRT | |
| 90 | Channel 3 | Actual setpoint | 2 Bytes | 9.1 temperature (°C) | CRT |
| 91 | Channel 3 | DPT_RHCC Status | 2 Bytes | CRT | |
| 92 | Channel 3 | Mode selection | 1 Byte | CW | |
| 92 | Channel 3 | Mode selection | 1 Byte | CRWT | |
| 93 | Channel 3 | Set point offset (1=+/0=-) | 1 Bit | CW | |
| 94 | Channel 3 | Flow temperature | 2 Bytes | 9.1 temperature (°C) | CW |
| 95 | 1 Byte | ||||
| 96 | Channel 3 | Error temperature sensor | 1 Bit | CRT | |
| 97 | 1 Byte | ||||
| 98 | 1 Byte | ||||
| 99 | Channel 4 | Actual temperature value | 2 Bytes | 9.1 temperature (°C) | CRT |
| 100 | Channel 4 | Higher message value | 1 Bit | CRT | |
| 101 | Channel 4 | Below message value | 1 Bit | CRT | |
| 102 | Channel 4 | Frost alarm | 1 Bit | CRT | |
| 103 | Channel 4 | Heat alarm | 1 Bit | CRT | |
| 104 | Channel 4 | External sensor | 2 Bytes | 9.1 temperature (°C) | CW |
| 105 | Channel 4 | Setpoint comfort | 2 Bytes | 9.1 temperature (°C) | CRWT |
| 106 | Channel 4 | Set point value offset | 2 Bytes | 9.2 temperature difference (K) | CW |
| 106 | Channel 4 | Set point value offset | 2 Bytes | 9.2 temperature difference (K) | CWT |
| 107 | Channel 4 | Control value heating | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 107 | Channel 4 | Control value heating | 1 Bit | CRT | |
| 108 | Channel 4 | Control value cooling | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 108 | Channel 4 | Control value cooling | 1 Bit | CRT | |
| 108 | Channel 4 | Status: 0=Cool 1=Heat | 1 Bit | CRT | |
| 109 | Channel 4 | Mode comfort | 1 Bit | 1.1 switch | CW |
| 110 | Channel 4 | Mode night | 1 Bit | 1.1 switch | CW |
| 111 | Channel 4 | Mode frost protection | 1 Bit | 1.1 switch | CW |
| 111 | Channel 4 | Mode heat protection | 1 Bit | 1.1 switch | CW |
| 111 | Channel 4 | Mode frost/heat protection | 1 Bit | 1.1 switch | CW |
| 112 | Channel 4 | Heating disable object | 1 Bit | 1.3 enable | CW |
| 113 | Channel 4 | Cooling disable object | 1 Bit | 1.3 enable | CW |
| 114 | Channel 4 | Heating request | 1 Bit | 1.1 switch | CRT |
| 115 | Channel 4 | Cooling request | 1 Bit | 1.1 switch | CRT |
| 116 | Channel 4 | Heating/cooling switchover | 1 Bit | CWT | |
| 117 | Channel 4 | Max memory value | 2 Bytes | 9.1 temperature (°C) | CRT |
| 118 | Channel 4 | Min memory value | 2 Bytes | 9.1 temperature (°C) | CRT |
| 119 | Channel 4 | Min/max memory reset | 1 Bit | 1.3 enable | CW |
| 120 | Channel 4 | Reset setpoint value | 1 Bit | 1.3 enable | CW |
| 121 | Channel 4 | DPT_HVAC Status | 1 Byte | CRT | |
| 122 | Channel 4 | Error external sensor | 1 Bit | CRT | |
| 123 | Channel 4 | Actual setpoint | 2 Bytes | 9.1 temperature (°C) | CRT |
| 124 | Channel 4 | DPT_RHCC Status | 2 Bytes | CRT | |
| 125 | Channel 4 | Mode selection | 1 Byte | CW | |
| 125 | Channel 4 | Mode selection | 1 Byte | CRWT | |
| 126 | Channel 4 | Set point offset (1=+/0=-) | 1 Bit | CW | |
| 127 | Channel 4 | Flow temperature | 2 Bytes | 9.1 temperature (°C) | CW |
| 128 | 1 Byte | ||||
| 129 | Channel 4 | Error temperature sensor | 1 Bit | CRT | |
| 130 | 1 Byte | ||||
| 131 | 1 Byte | ||||
| 132 | Channel 5 | Actual temperature value | 2 Bytes | 9.1 temperature (°C) | CRT |
| 133 | Channel 5 | Higher message value | 1 Bit | CRT | |
| 134 | Channel 5 | Below message value | 1 Bit | CRT | |
| 135 | Channel 5 | Frost alarm | 1 Bit | CRT | |
| 136 | Channel 5 | Heat alarm | 1 Bit | CRT | |
| 137 | Channel 5 | External sensor | 2 Bytes | 9.1 temperature (°C) | CW |
| 138 | Channel 5 | Setpoint comfort | 2 Bytes | 9.1 temperature (°C) | CRWT |
| 139 | Channel 5 | Set point value offset | 2 Bytes | 9.2 temperature difference (K) | CW |
| 139 | Channel 5 | Set point value offset | 2 Bytes | 9.2 temperature difference (K) | CWT |
| 140 | Channel 5 | Control value heating | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 140 | Channel 5 | Control value heating | 1 Bit | CRT | |
| 141 | Channel 5 | Control value cooling | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 141 | Channel 5 | Control value cooling | 1 Bit | CRT | |
| 141 | Channel 5 | Status: 0=Cool 1=Heat | 1 Bit | CRT | |
| 142 | Channel 5 | Mode comfort | 1 Bit | 1.1 switch | CW |
| 143 | Channel 5 | Mode night | 1 Bit | 1.1 switch | CW |
| 144 | Channel 5 | Mode frost protection | 1 Bit | 1.1 switch | CW |
| 144 | Channel 5 | Mode heat protection | 1 Bit | 1.1 switch | CW |
| 144 | Channel 5 | Mode frost/heat protection | 1 Bit | 1.1 switch | CW |
| 145 | Channel 5 | Heating disable object | 1 Bit | 1.3 enable | CW |
| 146 | Channel 5 | Cooling disable object | 1 Bit | 1.3 enable | CW |
| 147 | Channel 5 | Heating request | 1 Bit | 1.1 switch | CRT |
| 148 | Channel 5 | Cooling request | 1 Bit | 1.1 switch | CRT |
| 149 | Channel 5 | Heating/cooling switchover | 1 Bit | CWT | |
| 150 | Channel 5 | Max memory value | 2 Bytes | 9.1 temperature (°C) | CRT |
| 151 | Channel 5 | Min memory value | 2 Bytes | 9.1 temperature (°C) | CRT |
| 152 | Channel 5 | Min/max memory reset | 1 Bit | 1.3 enable | CW |
| 153 | Channel 5 | Reset setpoint value | 1 Bit | 1.3 enable | CW |
| 154 | Channel 5 | DPT_HVAC Status | 1 Byte | CRT | |
| 155 | Channel 5 | Error external sensor | 1 Bit | CRT | |
| 156 | Channel 5 | Actual setpoint | 2 Bytes | 9.1 temperature (°C) | CRT |
| 157 | Channel 5 | DPT_RHCC Status | 2 Bytes | CRT | |
| 158 | Channel 5 | Mode selection | 1 Byte | CW | |
| 158 | Channel 5 | Mode selection | 1 Byte | CRWT | |
| 159 | Channel 5 | Set point offset (1=+/0=-) | 1 Bit | CW | |
| 160 | Channel 5 | Flow temperature | 2 Bytes | 9.1 temperature (°C) | CW |
| 161 | 1 Byte | ||||
| 162 | Channel 5 | Error temperature sensor | 1 Bit | CRT | |
| 163 | 1 Byte | ||||
| 164 | 1 Byte | ||||
| 165 | Channel 6 | Actual temperature value | 2 Bytes | 9.1 temperature (°C) | CRT |
| 166 | Channel 6 | Higher message value | 1 Bit | CRT | |
| 167 | Channel 6 | Below message value | 1 Bit | CRT | |
| 168 | Channel 6 | Frost alarm | 1 Bit | CRT | |
| 169 | Channel 6 | Heat alarm | 1 Bit | CRT | |
| 170 | Channel 6 | External sensor | 2 Bytes | 9.1 temperature (°C) | CW |
| 171 | Channel 6 | Setpoint comfort | 2 Bytes | 9.1 temperature (°C) | CRWT |
| 172 | Channel 6 | Set point value offset | 2 Bytes | 9.2 temperature difference (K) | CW |
| 172 | Channel 6 | Set point value offset | 2 Bytes | 9.2 temperature difference (K) | CWT |
| 173 | Channel 6 | Control value heating | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 173 | Channel 6 | Control value heating | 1 Bit | CRT | |
| 174 | Channel 6 | Control value cooling | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 174 | Channel 6 | Control value cooling | 1 Bit | CRT | |
| 174 | Channel 6 | Status: 0=Cool 1=Heat | 1 Bit | CRT | |
| 175 | Channel 6 | Mode comfort | 1 Bit | 1.1 switch | CW |
| 176 | Channel 6 | Mode night | 1 Bit | 1.1 switch | CW |
| 177 | Channel 6 | Mode frost protection | 1 Bit | 1.1 switch | CW |
| 177 | Channel 6 | Mode heat protection | 1 Bit | 1.1 switch | CW |
| 177 | Channel 6 | Mode frost/heat protection | 1 Bit | 1.1 switch | CW |
| 178 | Channel 6 | Heating disable object | 1 Bit | 1.3 enable | CW |
| 179 | Channel 6 | Cooling disable object | 1 Bit | 1.3 enable | CW |
| 180 | Channel 6 | Heating request | 1 Bit | 1.1 switch | CRT |
| 181 | Channel 6 | Cooling request | 1 Bit | 1.1 switch | CRT |
| 182 | Channel 6 | Heating/cooling switchover | 1 Bit | CWT | |
| 183 | Channel 6 | Max memory value | 2 Bytes | 9.1 temperature (°C) | CRT |
| 184 | Channel 6 | Min memory value | 2 Bytes | 9.1 temperature (°C) | CRT |
| 185 | Channel 6 | Min/max memory reset | 1 Bit | 1.3 enable | CW |
| 186 | Channel 6 | Reset setpoint value | 1 Bit | 1.3 enable | CW |
| 187 | Channel 6 | DPT_HVAC Status | 1 Byte | CRT | |
| 188 | Channel 6 | Error external sensor | 1 Bit | CRT | |
| 189 | Channel 6 | Actual setpoint | 2 Bytes | 9.1 temperature (°C) | CRT |
| 190 | Channel 6 | DPT_RHCC Status | 2 Bytes | CRT | |
| 191 | Channel 6 | Mode selection | 1 Byte | CW | |
| 191 | Channel 6 | Mode selection | 1 Byte | CRWT | |
| 192 | Channel 6 | Set point offset (1=+/0=-) | 1 Bit | CW | |
| 193 | Channel 6 | Flow temperature | 2 Bytes | 9.1 temperature (°C) | CW |
| 194 | 1 Byte | ||||
| 195 | Channel 6 | Error temperature sensor | 1 Bit | CRT | |
| 196 | 1 Byte | ||||
| 197 | 1 Byte | ||||
| 198 | 1 Bit | ||||
| 199 | 1 Bit | ||||
| 200 | 1 Bit | ||||
| 201 | 1 Bit | ||||
| 202 | 1 Bit |
Parameters (73)
| Parameter | Type | Default |
|---|---|---|
| Startup delaytime | list | 0 s |
| Select hardware | list | SCN-RT6AP.01 with Sensor AP |
| Advanced function can be apply only for hardware starting from version R1.2 | text | <- TIP |
| Setpoint frost protaction for all channels | list | 7 °C |
| Setpoint heat protection for all channels | list | 35 °C |
| Flow temperature | list | 35 °C |
| Channel 1 | list | inactive |
| Send actual value after change of | list | send disable |
| Send actual temperature cyclically | list | send disable |
| Send min/max value | list | send disable |
| Internal sensor correction value (value * 0.1K) | signedInt -50…50 | 0 |
| Internal/external sensor | list | 100 % intern |
| Alarms | list | inactive |
| Frostalarm if value < | list | 7 °C |
| Heatalarm if value > | list | 35 °C |
| Messages | list | inactive |
| Message if value > | list | 26 °C |
| Message if value < | list | 13 °C |
| Controller type | list | Heating |
| Priority | list | Frost(Heat protection)/Comfort/Night/Standby |
| Extended area of set point | list | No |
| Basic comfort setpoint (°C) | list | 21,0 °C |
| Standby reduction (K) | list | 3,0 K |
| Night reduction (K) | list | 2,0 K |
| Max setpoint offset | list | 3,0 K |
| Set point value offset via 2Byte object | list | inactive |
| Send status of setpoint offset | list | inactive |
| Advanced function can be apply only for hardware starting from version R3.3 | text | <- TIP |
| Setpoint value offset via 1Bit object | list | inactive |
| Step range for 1Bit Setpoint offset | list | 0,5 K |
| Max setpoint offset vaild for | list | Comfort |
| Reset setpoint offset after change of mode | list | No |
| Send setpoint change | list | No |
| Flow temperature limit | list | inactive |
| Operating mode after reset | list | Comfort with parameterized set point |
| Send status on object 26 "Mode selection" | list | No |
| Heating disable object | list | inactive |
| Heating request object enabled | list | No |
| Standby increase (K) | list | 3,0 K |
| Night increase (K) | list | 2,0 K |
| Cooling disable object | list | inactive |
| Cooling request object enabled | list | No |
| Dead zone between heating and cooling (K) | list | 3,0 K |
| Setpoint | list | PI control continuous |
| Direction of controller | list | normal |
| Max value of control value | list | 100% |
| Heating system | list | Adjustment via control parameter |
| Heating system | list | Underfloor heating (4K / 150min) |
| Proportional range (K) | list | 4 K |
| Reset time (min) | list | 150 min |
| Send control value cyclic | list | send disable |
| Send control value at the failure of measurement | list | 30% Comfort; 15% Night; 7% Frost/Heat protection |
| PWM cycletime (min) | list | 10 min |
| Hysteresis (K) | list | 0,5 K |
| Cooling system | list | Adjustment via control parameter |
| Cooling system | list | Split Unit (4K / 60min) |
| Reset time (min) | list | 60 min |
| System | list | 2 Pipe system |
| Heating cooling switch over | list | automatically |
| Send control value for heating and cooling cyclic | list | send disable |
| Send control value at the failure of measurement for Heating and Cooling | list | 30% Comfort; 15% Night; 7% Frost/Heat protection |
| Channel 2 | list | inactive |
| Step range | list | 0,5 K |
| Send status on object 59 "Mode selection" | list | No |
| Channel 3 | list | inactive |
| Send status on object 92 "Mode selection" | list | No |
| Channel 4 | list | inactive |
| Send status on object 125 "Mode selection" | list | No |
| Channel 5 | list | inactive |
| Send status on object 158 "Mode selection" | list | No |
| Channel 6 | list | inactive |
| Send status on object 191 "Mode selection" | list | No |
| Dead zone between heating and cooling (K) | list | 2,0 K |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Temperature controller 6 fold AP 1.3 latest | $0043 | 34C2 | 2026-11-25 | 171 KB | Download |
About this file
This is the official ETS product database for the MDT technologies GmbH Controller / Sensor 6-fold AP (SCN-RT6AP.01), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from MDT technologies GmbH
- SCN-LSD01.01 Brightness Sensor/Controller SCN-LSD01.01
- SCN-MGSUP.01 Air quality/CO2 sensor SCN-MGSUP.01
- Glass Room temperature controller SCN-RT1Gx.01
- Room Temperature Controller 1-fold UP SCN-RT1UP.01
- Room Temp. Contr. 1-fold with adjustment knob UP SCN-RT1UPE.01
- Temperature controller / sensor 2-fold UP SCN-RT2UP.01
- Temperature controller / sensor 4-fold UP SCN-RT4UP.01
- Temperature Controller 6-fold, 2SU MDRC SCN-RT6REG.01
- SCN-RT8REG.02 Temperature Controller 8-fold MDRC SCN-RT8REG.02
- SCN-RTN55S.01 Room Temperature Extension Unit Smart 55 SCN-RTN55S.01
- SCN-RTN60S.01 Room Temperature Extension Unit Smart 60 CH SCN-RTN60S.01
- SCN-RTN63S.01 Room Temperature Extension Unit Smart 63 SCN-RTN63S.01