Temperature controller / sensor 2-fold UP SCN-RT2UP.01

MDT technologies GmbH · Order number SCN-RT2UP.01 · Temperature Controller › Temperature Controller flush mounted

2 Channel Temperature Controller flush mounted

Download .knxprod Temperature controller 2 fold UP 1.3 · 123 KB

Product

ManufacturerMDT technologies GmbH
Product nameTemperature controller / sensor 2-fold UP
Order numberSCN-RT2UP.01
HardwareTemperaturregler/Sensor 2-fach UP
MediumTwisted Pair
Bus current (mA)5
Rail mountedNo
RegistrationCertified · 2014-10-13
Languagesde-DE, en-US, es-ES, fr-FR
Catalog entryM-0083_H-63-0_HP-0049-13-86F4_CI-SCN.2DRT2UP.2E01-1
Fingerprint86F4
SHA-2565d17f1901b63612493d407884fc494fbd37ff44f29e80ea642c8de9b67bf4e57
First seen2026-11-25
Markets69 markets

Application program: Temperature controller 2 fold UP 1.3

Application number$0049
Version1.3
Mask versionMV-0701 (7.1)
KNX Data SecureNo
Minimum ETS version3.0d
Parameters218
Group objects217
Group objects (217)
NoNameFunctionSizeDPTFlags
0Channel 1Actual temperature value2 Bytes9.1 temperature (°C)CRT
1Channel 1Higher message value1 BitCRT
2Channel 1Below message value 1 BitCRT
3Channel 1Frost alarm1 BitCRT
4Channel 1Heat alarm1 BitCRT
5Channel 1External sensor2 Bytes9.1 temperature (°C)CW
6Channel 1Setpoint comfort2 Bytes9.1 temperature (°C)CRWT
7Channel 1Set point value offset2 Bytes9.2 temperature difference (K)CW
7Channel 1Set point value offset2 Bytes9.2 temperature difference (K)CWT
8Channel 1Control value heating1 Byte5.1 percentage (0..100%)CRT
8Channel 1Control value heating1 BitCRT
9Channel 1Control value cooling1 Byte5.1 percentage (0..100%)CRT
9Channel 1Control value cooling1 BitCRT
9Channel 1Requirement 0=Cool 1=Heat1 BitCRT
10Channel 1Mode comfort1 Bit1.1 switchCW
11Channel 1Mode night1 Bit1.1 switchCW
12Channel 1Mode frost protection1 Bit1.1 switchCW
12Channel 1Mode heat protection1 Bit1.1 switchCW
12Channel 1Mode frost/heat protection1 Bit1.1 switchCW
13Channel 1Heating disable object1 Bit1.3 enableCW
14Channel 1Cooling disable object1 Bit1.3 enableCW
15Channel 1Heating request1 Bit1.1 switchCRT
16Channel 1Cooling request1 Bit1.1 switchCRT
17Channel 1Heating/cooling switchover1 BitCWT
18Channel 1Max memory value2 Bytes9.1 temperature (°C)CRT
19Channel 1Min memory value2 Bytes9.1 temperature (°C)CRT
20Channel 1Min/max memory reset1 Bit1.3 enableCW
21Channel 1Reset setpoint value1 Bit1.3 enableCW
22Channel 1DPT_HVAC Status1 ByteCRT
23Channel 1Error external sensor1 BitCRT
24Channel 1Actual setpoint2 Bytes9.1 temperature (°C)CRT
25Channel 1DPT_RHCC Status 2 BytesCRT
26Channel 1Mode selection1 ByteCW
26Channel 1Mode selection1 ByteCRWT
27Channel 1Set point offset (1=+/0=-)1 BitCW
28Channel 1Flow temperature2 Bytes9.1 temperature (°C)CW
291 Byte
30Channel 1Error temperature sensor1 BitCRT
311 Byte
321 Byte
33Channel 2Actual temperature value2 Bytes9.1 temperature (°C)CRT
34Channel 2Higher message value1 BitCRT
35Channel 2Below message value 1 BitCRT
36Channel 2Frost alarm1 BitCRT
37Channel 2Heat alarm1 BitCRT
38Channel 2External sensor2 Bytes9.1 temperature (°C)CW
39Channel 2Setpoint comfort2 Bytes9.1 temperature (°C)CRWT
40Channel 2Set point value offset2 Bytes9.2 temperature difference (K)CW
40Channel 2Set point value offset2 Bytes9.2 temperature difference (K)CWT
41Channel 2Control value heating1 Byte5.1 percentage (0..100%)CRT
41Channel 2Control value heating1 BitCRT
42Channel 2Control value cooling1 Byte5.1 percentage (0..100%)CRT
42Channel 2Control value cooling1 BitCRT
42Channel 2Requirement 0=Cool 1=Heat1 BitCRT
43Channel 2Mode comfort1 Bit1.1 switchCW
44Channel 2Mode night1 Bit1.1 switchCW
45Channel 2Mode frost protection1 Bit1.1 switchCW
45Channel 2Mode heat protection1 Bit1.1 switchCW
45Channel 2Mode frost/heat protection1 Bit1.1 switchCW
46Channel 2Heating disable object1 Bit1.3 enableCW
47Channel 2Cooling disable object1 Bit1.3 enableCW
48Channel 2Heating request1 Bit1.1 switchCRT
49Channel 2Cooling request1 Bit1.1 switchCRT
50Channel 2Heating/cooling switchover1 BitCWT
51Channel 2Max memory value2 Bytes9.1 temperature (°C)CRT
52Channel 2Min memory value2 Bytes9.1 temperature (°C)CRT
53Channel 2Min/max memory reset1 Bit1.3 enableCW
54Channel 2Reset setpoint value1 Bit1.3 enableCW
55Channel 2DPT_HVAC Status1 ByteCRT
56Channel 2Error external sensor1 BitCRT
57Channel 2Actual setpoint2 Bytes9.1 temperature (°C)CRT
58Channel 2DPT_RHCC Status 2 BytesCRT
59Channel 2Mode selection1 ByteCW
59Channel 2Mode selection1 ByteCRWT
60Channel 2Set point offset (1=+/0=-)1 BitCW
61Channel 2Flow temperature2 Bytes9.1 temperature (°C)CW
621 Byte
63Channel 2Error temperature sensor1 BitCRT
641 Byte
651 Byte
66Channel 3Actual temperature value2 Bytes9.1 temperature (°C)CRT
67Channel 3Higher message value1 BitCRT
68Channel 3Below message value 1 BitCRT
69Channel 3Frost alarm1 BitCRT
70Channel 3Heat alarm1 BitCRT
71Channel 3External sensor2 Bytes9.1 temperature (°C)CW
72Channel 3Setpoint comfort2 Bytes9.1 temperature (°C)CRWT
73Channel 3Set point value offset2 Bytes9.2 temperature difference (K)CW
74Channel 3Control value heating1 ByteCRT
75Channel 3Control value cooling1 ByteCRT
76Channel 3Mode comfort1 Bit1.1 switchCW
77Channel 3Mode night1 Bit1.1 switchCW
78Channel 3Mode frost/heat protection1 Bit1.1 switchCW
79Channel 3Heating disable object1 Bit1.3 enableCW
80Channel 3Cooling disable object1 Bit1.3 enableCW
81Channel 3Heating request1 Bit1.1 switchCRT
82Channel 3Cooling request1 Bit1.1 switchCRT
83Channel 3Heating/cooling switchover1 BitCWT
84Channel 3Max memory value2 Bytes9.1 temperature (°C)CRT
85Channel 3Min memory value2 Bytes9.1 temperature (°C)CRT
86Channel 3Min/max memory reset1 Bit1.3 enableCW
87Channel 3Reset setpoint value1 Bit1.3 enableCW
88Channel 3DPT_HVAC Status1 ByteCRT
89Channel 3Error external sensor1 BitCRT
90Channel 3Actual setpoint2 Bytes9.1 temperature (°C)CRT
91Channel 3DPT_RHCC Status 2 BytesCRT
92Channel 3Mode selection1 ByteCW
93Channel 3Set point offset (1=+/0=-)1 BitCW
941 Byte
951 Byte
961 Byte
971 Byte
981 Byte
99Channel 4Actual temperature value2 Bytes9.1 temperature (°C)CRT
100Channel 4Higher message value1 BitCRT
101Channel 4Below message value 1 BitCRT
102Channel 4Frost alarm1 BitCRT
103Channel 4Heat alarm1 BitCRT
104Channel 4External sensor2 Bytes9.1 temperature (°C)CW
105Channel 4Setpoint comfort2 Bytes9.1 temperature (°C)CRWT
106Channel 4Set point value offset2 Bytes9.2 temperature difference (K)CW
107Channel 4Control value heating1 ByteCRT
108Channel 4Control value cooling1 ByteCRT
109Channel 4Mode comfort1 Bit1.1 switchCW
110Channel 4Mode night1 Bit1.1 switchCW
111Channel 4Mode frost/heat protection1 Bit1.1 switchCW
112Channel 4Heating disable object1 Bit1.3 enableCW
113Channel 4Cooling disable object1 Bit1.3 enableCW
114Channel 4Heating request1 Bit1.1 switchCRT
115Channel 4Cooling request1 Bit1.1 switchCRT
116Channel 4Heating/cooling switchover1 BitCWT
117Channel 4Max memory value2 Bytes9.1 temperature (°C)CRT
118Channel 4Min memory value2 Bytes9.1 temperature (°C)CRT
119Channel 4Min/max memory reset1 Bit1.3 enableCW
120Channel 4Reset setpoint value1 Bit1.3 enableCW
121Channel 4DPT_HVAC Status1 ByteCRT
122Channel 4Error external sensor1 BitCRT
123Channel 4Actual setpoint2 Bytes9.1 temperature (°C)CRT
124Channel 4DPT_RHCC Status 2 BytesCRT
125Channel 4Mode selection1 ByteCW
126Channel 4Set point offset (1=+/0=-)1 BitCW
1271 Byte
1281 Byte
1291 Byte
1301 Byte
1311 Byte
132Channel 5Actual temperature value2 Bytes9.1 temperature (°C)CRT
133Channel 5Higher message value1 BitCRT
134Channel 5Below message value 1 BitCRT
135Channel 5Frost alarm1 BitCRT
136Channel 5Heat alarm1 BitCRT
137Channel 5External sensor2 Bytes9.1 temperature (°C)CW
138Channel 5Setpoint comfort2 Bytes9.1 temperature (°C)CRWT
139Channel 5Set point value offset2 Bytes9.2 temperature difference (K)CW
140Channel 5Control value heating1 ByteCRT
141Channel 5Control value cooling1 ByteCRT
142Channel 5Mode comfort1 Bit1.1 switchCW
143Channel 5Mode night1 Bit1.1 switchCW
144Channel 5Mode frost/heat protection1 Bit1.1 switchCW
145Channel 5Heating disable object1 Bit1.3 enableCW
146Channel 5Cooling disable object1 Bit1.3 enableCW
147Channel 5Heating request1 Bit1.1 switchCRT
148Channel 5Cooling request1 Bit1.1 switchCRT
149Channel 5Heating/cooling switchover1 BitCWT
150Channel 5Max memory value2 Bytes9.1 temperature (°C)CRT
151Channel 5Min memory value2 Bytes9.1 temperature (°C)CRT
152Channel 5Min/max memory reset1 Bit1.3 enableCW
153Channel 5Reset setpoint value1 Bit1.3 enableCW
154Channel 5DPT_HVAC Status1 ByteCRT
155Channel 5Error external sensor1 BitCRT
156Channel 5Actual setpoint2 Bytes9.1 temperature (°C)CRT
157Channel 5DPT_RHCC Status 2 BytesCRT
158Channel 5Mode selection1 ByteCW
159Channel 5Set point offset (1=+/0=-)1 BitCW
1601 Byte
1611 Byte
1621 Byte
1631 Byte
1641 Byte
165Channel 6Actual temperature value2 Bytes9.1 temperature (°C)CRT
166Channel 6Higher message value1 BitCRT
167Channel 6Below message value 1 BitCRT
168Channel 6Frost alarm1 BitCRT
169Channel 6Heat alarm1 BitCRT
170Channel 6External sensor2 Bytes9.1 temperature (°C)CW
171Channel 6Setpoint comfort2 Bytes9.1 temperature (°C)CRWT
172Channel 6Set point value offset2 Bytes9.2 temperature difference (K)CW
173Channel 6Control value heating1 ByteCRT
174Channel 6Control value cooling1 ByteCRT
175Channel 6Mode comfort1 Bit1.1 switchCW
176Channel 6Mode night1 Bit1.1 switchCW
177Channel 6Mode frost/heat protection1 Bit1.1 switchCW
178Channel 6Heating disable object1 Bit1.3 enableCW
179Channel 6Cooling disable object1 Bit1.3 enableCW
180Channel 6Heating request1 Bit1.1 switchCRT
181Channel 6Cooling request1 Bit1.1 switchCRT
182Channel 6Heating/cooling switchover1 BitCWT
183Channel 6Max memory value2 Bytes9.1 temperature (°C)CRT
184Channel 6Min memory value2 Bytes9.1 temperature (°C)CRT
185Channel 6Min/max memory reset1 Bit1.3 enableCW
186Channel 6Reset setpoint value1 Bit1.3 enableCW
187Channel 6DPT_HVAC Status1 ByteCRT
188Channel 6Error external sensor1 BitCRT
189Channel 6Actual setpoint2 Bytes9.1 temperature (°C)CRT
190Channel 6DPT_RHCC Status 2 BytesCRT
191Channel 6Mode selection1 ByteCW
192Channel 6Set point offset (1=+/0=-)1 BitCW
1931 Byte
1941 Byte
1951 Byte
1961 Byte
1971 Byte
1981 Bit
1991 Bit
2001 Bit
2011 Bit
2021 Bit
Parameters (62)
ParameterTypeDefault
Startup delaytimelist0 s
Select hardwarelistSCN-RT6AP.01 with Sensor AP
Setpoint frost protaction for all channelslist7 °C
Setpoint heat protection for all channelslist35 °C
Flow temperaturelist35 °C
Channel 1listinactive
Send actual value after change oflistsend disable
Send actual temperature cyclicallylistsend disable
Send min/max valuelistsend disable
Internal sensor correction value (value * 0.1K)signedInt -50…500
Internal/external sensorlist100 % intern
Alarmslistinactive
Frostalarm if value <list7 °C
Heatalarm if value >list35 °C
Messageslistinactive
Message if value >list26 °C
Message if value <list13 °C
Controller typelistHeating
PrioritylistFrost(Heat protection)/Comfort/Night/Standby
Extended area of set pointlistNo
Basic comfort setpoint (°C)list21,0 °C
Standby reduction (K)list3,0 K
Night reduction (K)list2,0 K
Max setpoint offsetlist3,0 K
Set point value offset via 2Byte objectlistinactive
Send status of setpoint offsetlistinactive
Advanced function can be apply only for hardware starting from version R3.3text<- TIP
Setpoint value offset via 1Bit objectlistinactive
Step rangelist0,5 K
Max setpoint offset vaild forlistComfort
Reset setpoint offset after change of modelistNo
Send setpoint changelistNo
Flow temperature limitlistinactive
Operating mode after resetlistComfort with parameterized set point
Send status on object 26 "Mode selection"listNo
Heating disable objectlistinactive
Heating request object enabledlistNo
Standby increase (K)list3,0 K
Night increase (K)list2,0 K
Cooling disable objectlistinactive
Cooling request object enabledlistNo
Dead zone between heating and cooling (K)list3,0 K
SetpointlistPI control continuous
Direction of controllerlistnormal
Max value of control valuelist100%
Heating systemlistAdjustment via control parameter
Heating systemlistUnderfloor heating (4K / 150min)
Proportional range (K)list4 K
Reset time (min)list150 min
Send control value cycliclistsend disable
Send control value at the failure of measurementlist30% Comfort; 15% Night; 7% Frost/Heat protection
PWM cycletime (min)list10 min
Hysteresis (K)list0,5 K
Cooling systemlistAdjustment via control parameter
Cooling systemlistSplit Unit (4K / 60min)
Reset time (min)list60 min
Systemlist2 Pipe system
Heating cooling switch overlistautomatically
Send control value for heating and cooling cycliclistsend disable
Send control value at the failure of measurement for Heating and Coolinglist30% Comfort; 15% Night; 7% Frost/Heat protection
Channel 2listinactive
Send status on object 59 "Mode selection"listNo

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Temperature controller 2 fold UP 1.3 latest$004986F42026-11-25123 KBDownload

About this file

This is the official ETS product database for the MDT technologies GmbH Temperature controller / sensor 2-fold UP (SCN-RT2UP.01), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from MDT technologies GmbH

All MDT technologies GmbH products