MDT technologies GmbH SCN-ACG0PAN.01 KNX Gateway for Panasonic Etherea air conditioning units, flush mounted

KNX Gateway for Panasonic Etherea air conditioning units, flush mounted SCN-ACG0PAN.01

MDT technologies GmbH · Order number SCN-ACG0PAN.01 · System Devices › KNX Gateways

Download .knxprod KNX Gateway for Panasonic Etherea air conditioning units, flush mounted 1.5 · 196 KB

Product

ManufacturerMDT technologies GmbH
Product nameKNX Gateway for Panasonic Etherea air conditioning units, flush mounted
Order numberSCN-ACG0PAN.01
HardwarePA AC Interface
MediumTwisted Pair
Bus current (mA)6
Rail mountedNo
RegistrationCertified · 2026-06-22
Languagesde-DE, en-US, es-ES
Catalog entryM-0083_H-INT03-1-O0077_HP-0483-15-A264-O0077_CI-SCN.2DACG0PAN.2E01-1
FingerprintA264
SHA-256792a3a5d92b273aa081f2fc186699715f13edd0ef9d9819ae1172ee19c7de552
First seen2026-11-25
Markets69 markets

Application program: KNX Gateway for Panasonic Etherea air conditioning units, flush mounted 1.5

Application number$0483
Version1.5
Mask versionMV-0025 (2.5)
KNX Data SecureNo
Minimum ETS version5.0
Parameters320
Group objects177
Group objects (177)
NoNameFunctionSizeDPTFlags
0ON/OFF1 = ON, 0 = OFF1 Bit1.1 switchCWT
1Mode: Powerful1 = Set Powerful Mode1 Bit1.2 booleanCWT
2Mode: Quiet1 = Set Quiet Mode1 Bit1.2 booleanCWT
3HVAC Mode0 = Auto, 1 = Heat, 3 = Cool, 9 = Fan, 14 = Dry1 ByteCWT
4Mode: Cool/Heat0 = Cool, 1 = Heat1 BitCWT
5Mode: Cool & On0 % = Off; 0.1 % - 100 % = On + Cool1 Byte5.1 percentage (0..100%)CWT
6Mode: Heat & On0 % = Off; 0.1 % - 100 % = On + Heat1 Byte5.1 percentage (0..100%)CWT
7Mode: Auto1 = Set AUTO Mode1 Bit1.2 booleanCWT
8Mode: Heat1 = Set HEAT Mode1 Bit1.2 booleanCWT
9Mode: Cool1 = Set COOL Mode1 Bit1.2 booleanCWT
10Mode: Fan1 = Set FAN Mode1 Bit1.2 booleanCWT
11Mode: Dry1 = Set DRY Mode1 Bit1.2 booleanCWT
12Mode [+/-]0 = Decrease, 1 = Increase1 BitCW
12Mode [+/-]0 = Up, 1 = Down1 Bit1.8 up/downCW
13Fan Speed / 5 SpeedsThresholds: 30 %, 50 %, 70 %, 90 %1 Byte5.1 percentage (0..100%)CWT
13Fan Speed / 5 SpeedsSpeed values: 1, 2, 3, 4, 51 Byte5.10 counter pulses (0..255)CWT
14Fan Speed Man/Auto0 = Manual; 1 = Auto1 Bit1.2 booleanCWT
15Fan Speed 11 = Set Fan Speed 11 Bit1.2 booleanCWT
16Fan Speed 21 = Set Fan Speed 21 Bit1.2 booleanCWT
17Fan Speed 31 = Set Fan Speed 31 Bit1.2 booleanCWT
18Fan Speed 41 = Set Fan Speed 41 Bit1.2 booleanCWT
19Fan Speed 51 = Set Fan Speed 51 Bit1.2 booleanCWT
20Fan Speed [+/-]0 = Decrease, 1 = Increase1 BitCW
20Fan Speed [+/-]0 = Up, 1 = Down1 Bit1.8 up/downCW
21Vanes U-D / 5 PositionsThresholds: 30 %, 50 %, 70 %, 90 %1 Byte5.1 percentage (0..100%)CWT
21Vanes U-D / 5 PositionsPosition values: 1, 2, 3, 4, 51 Byte5.10 counter pulses (0..255)CWT
22Vanes U-D Man/Auto0 = Manual; 1 = Auto1 Bit1.2 booleanCWT
23Vanes U-D Position 11 = Set Position 11 Bit1.2 booleanCWT
24Vanes U-D Position 21 = Set Position 21 Bit1.2 booleanCWT
25Vanes U-D Position 31 = Set Position 31 Bit1.2 booleanCWT
26Vanes U-D Position 41 = Set Position 41 Bit1.2 booleanCWT
27Vanes U-D Position 51 = Set Position 51 Bit1.2 booleanCWT
28Vanes U-D [+/-]0 = Up, 1 = Down1 Bit1.8 up/downCW
28Vanes U-D [+/-]0 = Decrease, 1 = Increase1 BitCW
29Vanes L-R / 5 PositionsThresholds: 30 %, 50 %, 70 %, 90 %1 Byte5.1 percentage (0..100%)CWT
29Vanes L-R / 5 PositionsPosition values: 1, 2, 3, 4, 51 Byte5.10 counter pulses (0..255)CWT
30Vanes L-R Man/Auto0 = Manual; 1 = Auto1 Bit1.2 booleanCWT
31Vanes L-R Position 11 = Set Position 11 Bit1.2 booleanCWT
32Vanes L-R Position 21 = Set Position 21 Bit1.2 booleanCWT
33Vanes L-R Position 31 = Set Position 31 Bit1.2 booleanCWT
34Vanes L-R Position 41 = Set Position 41 Bit1.2 booleanCWT
35Vanes L-R Position 51 = Set Position 51 Bit1.2 booleanCWT
36Vanes L-R [+/-]0 = Decrease, 1 = Increase1 BitCW
36Vanes L-R [+/-]0 = Up, 1 = Down1 Bit1.8 up/downCW
37Setpoint TemperatureºC2 Bytes9.1 temperature (°C)CWT
38Setpoint Temperature [+/-]0 = Decrease, 1 = Increase1 BitCW
38Setpoint Temperature [+/-]0 = Up, 1 = Down1 Bit1.8 up/downCW
39Ambient TemperatureºC2 Bytes9.1 temperature (°C)CWT
40TodayToday's date3 Bytes11.1 dateCWT
41Reset Energy Counter1 = Reset counter1 BitCWT
42Switch Off Timeout0 = Stop, 1 = Start1 Bit1.10 start/stopCWT
42Window Contact Status0 = Open, 1 = Closed1 Bit1.9 open/closeCWT
43Occupancy0 = Not Occupied, 1 = Occupied1 BitCWT
44Sleep Timeout0 = Stop, 1 = Start1 Bit1.10 start/stopCWT
45Lock Remote Control0 = Unlock, 1 = Lock1 Bit1.2 booleanCWT
46Lock Control Objects0 = Unlock, 1 = Lock1 Bit1.2 booleanCWT
47Power Mode0 = Stop, 1 = Start1 Bit1.10 start/stopCWT
48Eco Mode0 = Stop, 1 = Start1 Bit1.10 start/stopCWT
49Additional Heating0 = Stop, 1 = Start1 Bit1.10 start/stopCWT
50Additional Cooling0 = Stop, 1 = Start1 Bit1.10 start/stopCWT
51Execute Scene0...4 = Execute Scene 1-51 ByteCWT
51Save/Execute Scene0...4 = Execute Scene 1-5, 128...132 = Save Scene 1-51 ByteCWT
52Save Scene 11 = Save Scene1 Bit1.2 booleanCW
53Save Scene 21 = Save Scene1 Bit1.2 booleanCW
54Save Scene 31 = Save Scene1 Bit1.2 booleanCW
55Save Scene 41 = Save Scene1 Bit1.2 booleanCW
56Save Scene 51 = Save Scene1 Bit1.2 booleanCW
57Execute Scene 11 = Execute Scene1 Bit1.2 booleanCWT
58Execute Scene 21 = Execute Scene1 Bit1.2 booleanCWT
59Execute Scene 31 = Execute Scene1 Bit1.2 booleanCWT
60Execute Scene 41 = Execute Scene1 Bit1.2 booleanCWT
61Execute Scene 51 = Execute Scene1 Bit1.2 booleanCWT
62Input 1 - Lock object0 = Disable, 1 = Enable1 Bit1.3 enableCWT
62Input 1 - Lock object0 = False, 1 = True1 Bit1.2 booleanCWT
63Input 2 - Lock object0 = False, 1 = True1 Bit1.2 booleanCWT
63Input 2 - Lock object0 = Disable, 1 = Enable1 Bit1.3 enableCWT
64Input 3 - Lock object0 = False, 1 = True1 Bit1.2 booleanCWT
64Input 3 - Lock object0 = Disable, 1 = Enable1 Bit1.3 enableCWT
65Input 4 - Lock object0 = False, 1 = True1 Bit1.2 booleanCWT
65Input 4 - Lock object0 = Disable, 1 = Enable1 Bit1.3 enableCWT
66ON/OFFStatus: 1 = ON, 0 = OFF1 Bit1.1 switchCRT
67Mode: PowerfulStatus: 1 = Powerful is active1 Bit1.2 booleanCRT
68Mode: QuietStatus: 1 = Quiet is active1 Bit1.2 booleanCRT
69HVAC ModeStatus: 0 = Auto, 1 = Heat, 3 = Cool, 9 = Fan, 14 = Dry1 ByteCRT
70Mode: Cool/HeatStatus: 0 = Cool, 1 = Heat1 BitCRT
71Mode: AutoStatus: 1 = AUTO is active1 Bit1.2 booleanCRT
72Mode: HeatStatus: 1 = HEAT is active1 Bit1.2 booleanCRT
73Mode: CoolStatus: 1 = COOL is active1 Bit1.2 booleanCRT
74Mode: FanStatus: 1 = FAN is active1 Bit1.2 booleanCRT
75Mode: DryStatus: 1 = DRY is active1 Bit1.2 booleanCRT
76Mode: TextStatus: Maximum 14 characters14 Bytes16.1 Character String (ISO 8859-1)CRT
77Fan Speed / 5 SpeedsStatus: 20 %, 40 %, 60 %, 80 %, 100 %1 Byte5.1 percentage (0..100%)CRT
77Fan Speed / 5 SpeedsStatus: Speed values 1, 2, 3, 4, 51 Byte5.10 counter pulses (0..255)CRT
78Fan Speed Man/AutoStatus: 0 = Manual; 1 = Auto1 Bit1.2 booleanCRT
79Fan Speed 1Status: 1 = Fan in Speed 11 Bit1.2 booleanCRT
80Fan Speed 2Status: 1 = Fan in Speed 21 Bit1.2 booleanCRT
81Fan Speed 3Status: 1 = Fan in Speed 31 Bit1.2 booleanCRT
82Fan Speed 4Status: 1 = Fan in Speed 41 Bit1.2 booleanCRT
83Fan Speed 5Status: 1 = Fan in Speed 51 Bit1.2 booleanCRT
84Fan Speed: TextStatus: Maximum 14 characters14 Bytes16.1 Character String (ISO 8859-1)CRT
85Vanes U-D / 5 PositionsStatus: 20 %, 40 %, 60 %, 80 %, 100 %1 Byte5.1 percentage (0..100%)CRT
85Vanes U-D / 5 PositionsStatus: Position values 1, 2, 3, 4, 51 Byte5.10 counter pulses (0..255)CRT
86Vanes U-D Man/AutoStatus: 0 = Manual; 1 = Auto1 Bit1.2 booleanCRT
87Vanes U-D Position 1Status: 1 = Vanes in Position 11 Bit1.2 booleanCRT
88Vanes U-D Position 2Status: 1 = Vanes in Position 21 Bit1.2 booleanCRT
89Vanes U-D Position 3Status: 1 = Vanes in Position 31 Bit1.2 booleanCRT
90Vanes U-D Position 4Status: 1 = Vanes in Position 41 Bit1.2 booleanCRT
91Vanes U-D Position 5Status: 1 = Vanes in Position 51 Bit1.2 booleanCRT
92Vanes U-D TextStatus: Maximum 14 characters14 Bytes16.1 Character String (ISO 8859-1)CRT
93Vanes L-R / 5 PositionsStatus: 20 %, 40 %, 60 %, 80 %, 100 %1 Byte5.1 percentage (0..100%)CRT
93Vanes L-R / 5 PositionsStatus: Position values 1, 2, 3, 4, 51 Byte5.10 counter pulses (0..255)CRT
94Vanes L-R Man/AutoStatus: 0 = Manual; 1 = Auto1 Bit1.2 booleanCRT
95Vanes L-R Position 1Status: 1 = Vanes in Position 11 Bit1.2 booleanCRT
96Vanes L-R Position 2Status: 1 = Vanes in Position 21 Bit1.2 booleanCRT
97Vanes L-R Position 3Status: 1 = Vanes in Position 31 Bit1.2 booleanCRT
98Vanes L-R Position 4Status: 1 = Vanes in Position 41 Bit1.2 booleanCRT
99Vanes L-R Position 5Status: 1 = Vanes in Position 51 Bit1.2 booleanCRT
100Vanes L-R TextStatus: Maximum 14 characters14 Bytes16.1 Character String (ISO 8859-1)CRT
101AC Setpoint TemperatureStatus (ºC)2 Bytes9.1 temperature (°C)CRT
102AC Return TemperatureStatus (ºC)2 Bytes9.1 temperature (°C)CRT
103Outdoor TemperatureStatus (ºC)2 Bytes9.1 temperature (°C)CRT
104Error/AlarmStatus: 0 = No alarm, 1 = Alarm1 BitCRT
105Error CodeStatus: 0 = No error / Any other see manual2 BytesCRT
106Error Text CodeStatus: 3 char PA Error; Empty - None14 Bytes16.1 Character String (ISO 8859-1)CRT
107Power ConsumptionStatus (W)4 Bytes14.56 power (W)CRT
108Today EnergyStatus (Wh)4 BytesCRT
109Yesterday EnergyStatus (Wh)4 BytesCRT
110Total EnergyStatus (Wh)4 BytesCRT
111TodayStatus: Today's date3 Bytes11.1 dateCRT
112Lock Remote ControlStatus: 0 = Unlocked, 1 = Locked1 Bit1.2 booleanCRT
113Lock Control ObjectsStatus: 0 = Unlocked, 1 = Locked1 Bit1.2 booleanCRT
114Power ModeStatus: 0 = OFF, 1 = ON1 Bit1.1 switchCRT
115Eco ModeStatus: 0 = OFF, 1 = ON1 Bit1.1 switchCRT
116Additional HeatingStatus: 0 = OFF, 1 = ON1 Bit1.1 switchCRT
117Additional CoolingStatus: 0 = OFF, 1 = ON1 Bit1.1 switchCRT
118Operating Hours CounterStatus: Number of operating hours2 Bytes7.1 pulsesCRT
119Current SceneStatus: 0...4 = Scene X+1, 63 = No Scene1 ByteCRT
120Input 1 - SwitchStatus: 0 = OFF, 1 = ON1 Bit1.1 switchCRT
120Input 1 - DimmingStatus: 0 = OFF, 1 = ON1 Bit1.1 switchCRT
120Input 1 - Shutter/BlindsStatus: 0 = Step Up; 1 = Step Down1 BitCRT
121Input 1 - DimmingStatus: Dimming step4 Bit3.7 dimming controlCRT
121Input 1 - Shutter/BlindsStatus: 0 = Move Up; 1 = Move Down1 Bit1.8 up/downCRT
121Input 1 - ValueStatus: 4 Byte unsigned value4 Bytes12.1 counter pulses (unsigned)CRT
121Input 1 - ValueStatus: 1 Byte unsigned value1 Byte5.10 counter pulses (0..255)CRT
121Input 1 - ValueStatus: 2 Byte signed value2 Bytes8.1 pulses differenceCRT
121Input 1 - ValueStatus: Temperature (ºC)2 Bytes9.1 temperature (°C)CRT
121Input 1 - ValueStatus: 2 Byte unsigned value2 Bytes7.1 pulsesCRT
122Input 2 - SwitchStatus: 0 = OFF, 1 = ON1 Bit1.1 switchCRT
122Input 2 - DimmingStatus: 0 = OFF, 1 = ON1 Bit1.1 switchCRT
122Input 2 - Shutter/BlindsStatus: 0 = Step Up; 1 = Step Down1 BitCRT
123Input 2 - Dimming Status: Dimming step4 Bit3.7 dimming controlCRT
123Input 2 - ValueStatus: 2 Byte unsigned value2 Bytes7.1 pulsesCRT
123Input 2 - ValueStatus: 1 Byte unsigned value1 Byte5.10 counter pulses (0..255)CRT
123Input 2 - Shutter/BlindsStatus: 0 = Move Up; 1 = Move Down1 Bit1.8 up/downCRT
123Input 2 - ValueStatus: 4 Byte unsigned value4 Bytes12.1 counter pulses (unsigned)CRT
123Input 2 - ValueStatus: Temperature (ºC)2 Bytes9.1 temperature (°C)CRT
123Input 2 - ValueStatus: 2 Byte signed value2 Bytes8.1 pulses differenceCRT
124Input 3 - SwitchStatus: 0 = OFF, 1 = ON1 Bit1.1 switchCRT
124Input 3 - DimmingStatus: 0 = OFF, 1 = ON1 Bit1.1 switchCRT
124Input 3 - Shutter/BlindsStatus: 0 = Step Up; 1 = Step Down1 BitCRT
125Input 3 - DimmingStatus: Dimming step4 Bit3.7 dimming controlCRT
125Input 3 - ValueStatus: 4 Byte unsigned value4 Bytes12.1 counter pulses (unsigned)CRT
125Input 3 - ValueStatus: Temperature (ºC)2 Bytes9.1 temperature (°C)CRT
125Input 3 - ValueStatus: 2 Byte signed value2 Bytes8.1 pulses differenceCRT
125Input 3 - ValueStatus: 2 Byte unsigned value2 Bytes7.1 pulsesCRT
125Input 3 - ValueStatus: 1 Byte unsigned value1 Byte5.10 counter pulses (0..255)CRT
125Input 3 - Shutter/BlindsStatus: 0 = Move Up; 1 = Move Down1 Bit1.8 up/downCRT
126Input 4 - SwitchStatus: 0 = OFF, 1 = ON1 Bit1.1 switchCRT
126Input 4 - DimmingStatus: 0 = OFF, 1 = ON1 Bit1.1 switchCRT
126Input 4 - Shutter/BlindsStatus: 0 = Step Up; 1 = Step Down1 BitCRT
127Input 4 - DimmingStatus: Dimming step4 Bit3.7 dimming controlCRT
127Input 4 - ValueStatus: 4 Byte unsigned value4 Bytes12.1 counter pulses (unsigned)CRT
127Input 4 - ValueStatus: Temperature (ºC)2 Bytes9.1 temperature (°C)CRT
127Input 4 - ValueStatus: 2 Byte signed value2 Bytes8.1 pulses differenceCRT
127Input 4 - ValueStatus: 2 Byte unsigned value2 Bytes7.1 pulsesCRT
127Input 4 - ValueStatus: 1 Byte unsigned value1 Byte5.10 counter pulses (0..255)CRT
127Input 4 - Shutter/BlindsStatus: 0 = Move Up; 1 = Move Down1 Bit1.8 up/downCRT
Parameters (190)
ParameterTypeDefault
Download latest database entry for this product and its User Manual from:texthttp://www.intesis.com
Send READs for Control objects on bus recovery (T & U flags must be active)listNo
> Delay before sending READs (sec)unsignedInt 0…3010
Scene to load on bus recovery / startup (needs to define values for that scene)list(none)
Enable object "Error Code"listNo
Disallow control from remote controllerlistNo
> Enable "Lock Remote Control" objectslistNo
Enable function "Lock Control Objects"listNo
Enable function "Operating Hours Counter"listNo
When mode is AUTO, Status objects report actual operating status (HEAT/COOL/..)listNo
Enable "Mode Cool/Heat" objects (for Control and Status)listNo
Enable PID-Compat. Scaling Mode ObjectslistNo
Enable use of +/- object for ModelistNo
> Datapoint typelist0 = Decrease, 1 = Increase [DPT_1.007]
Enable use of bit-type Mode objects (for Control)listNo
Enable use of bit-type Mode objects (for Status)listNo
Enable use of Text object for ModelistNo
ASCII strings shown in status object "Mode: Text"text<< 14-byte string values >>
> String when mode is AUTOtextAUTO
> String when mode is HEATtextHEAT
> String when mode is COOLtextCOOL
> String when mode is FANtextFAN
> String when mode is DRYtextDRY
Enable use of "Powerful" mode (AC feature)listNo
Enable use of "Quiet" mode (AC feature)listNo
Enable use of Power modelistNo
> Action time for this mode (minutes)unsignedInt 1…18030
> Setpoint delta increase (HEAT) or decrease (COOL)list2.0 ºC
> Fan SpeedlistSPEED 5
Enable use of Economy modelistNo
> Setpoint delta decrease (HEAT) or increase (COOL)list2.0 ºC
> Fan SpeedlistSPEED 1
Enable use of Sleep functionlistNo
> AC switch-off timeout (minutes)unsignedInt 0…18060
Enable use of Additional Heating modelistNo
> Fan SpeedlistAUTO
Enable use of Additional Cooling modelistNo
Enable "Fan Speed Man/Auto" objects (for Control and Status)listNo
Available fanspeeds in Indoor Unit (see docum. for your indoor unit)unsignedInt 2…75
Datapoint typelistScaling [DPT_5.001]
Enable use of +/- object for Fan SpeedlistNo
> Does +/- sequence include Fan Speed AUTO?listNo
> Roll-over Speed at upper/lower limit (when controlling with +/- object)listYes
Enable use of bit-type Fan Speed objects (for Control)listNo
Enable use of bit-type Fan Speed objects (for Status)listNo
Enable use of Text object for Fan SpeedlistNo
ASCII strings shown in status object "Fan Speed: Text"text<< 14-byte string values >>
> String when Fan Speed is AUTOtextAUTO
> String when Fan Speed is 1textSPEED 1
> String when Fan Speed is 2textSPEED 2
> String when Fan Speed is 3textSPEED 3
> String when Fan Speed is 4textSPEED 4
> String when Fan Speed is 5textSPEED 5
Indoor unit has Up-Down Vanes (see documentation of indoor unit)listYes
Enable "Vanes U-D Man/Auto" objects (for Control and Status)listNo
Enable use of +/- object for Vanes U-DlistNo
> Does +/- sequence include Vanes Up-Down AUTO?listNo
> Roll-over Vanes at upper/lower limit (when controlling with +/- object)listYes
Enable use of bit-type Vanes U-D objects (for Control)listNo
Enable use of bit-type Vanes U-D objects (for Status)listNo
Enable use of Text object for Vanes U-DlistNo
ASCII strings shown in status object "Vanes U-D: Text"text<< 14-byte string values >>
> String when Vanes U-D in AUTOtextU-D AUTO
> String when Vanes U-D in POS 1textU-D POS 1
> String when Vanes U-D in POS 2textU-D POS 2
> String when Vanes U-D in POS 3textU-D POS 3
> String when Vanes U-D in POS 4textU-D POS 4
> String when Vanes U-D in POS 5textU-D POS 5
Indoor unit has Left-Right Vanes (see documentation of indoor unit)listYes
Enable "Vanes L-R Man/Auto" objects (for Control and Status)listNo
Enable use of +/- object for Vanes L-RlistNo
> Does +/- sequence include Vanes Left-Right AUTO?listNo
Enable use of bit-type Vanes L-R objects (for Control)listNo
Enable use of bit-type Vanes L-R objects (for Status)listNo
Enable use of Text object for Vanes L-RlistNo
ASCII strings shown in status object "Vanes L-R: Text"text<< 14-byte string values >>
> String when Vanes L-R in AUTOtextL-R AUTO
> String when Vanes L-R in POS 1textL-R POS 1
> String when Vanes L-R in POS 2textL-R POS 2
> String when Vanes L-R in POS 3textL-R POS 3
> String when Vanes L-R in POS 4textL-R POS 4
> String when Vanes L-R in POS 5textL-R POS 5
Cyclic sending of "AC Setpoint Temperature" (in seconds; 0 = not active)unsignedInt 0…2550
Enable use of +/- object for Setpoint TemperaturelistNo
> [+/-] step sizelist1.0 ºC
Enable limits for object "Setpoint Temperature"listNo
> Lower limitlist16.0 ºC
> Upper limitlist30.0 ºC
Ambient temperature reference is provided from KNX (see User Guide if enabled)listNo
Enable use of sceneslistNo
Scenes can be saved from KNX buslistNo
Enable use of bit objects for scene executionlistNo
> Enable use of bit objects for saving scenes (from bus)listNo
Scene 1 presetlistNo
> Scene 1 / Value for ON/OFFlist(unchanged)
> Scene 1 / Value for Modelist(unchanged)
> Scene 1 / Value for Fan Speedlist(unchanged)
> Scene 1 / Value for Vanes U-D (if available)list(unchanged)
> Scene 1 / Value for Vanes L-R (if available)list(unchanged)
> Scene 1 / Value for Setpoint Templist(unchanged)
> Scene 1 / Value for Remote Locklist(unchanged)
Scene 2 presetlistNo
> Scene 2 / Value for ON/OFFlist(unchanged)
> Scene 2 / Value for Modelist(unchanged)
> Scene 2 / Value for Fan Speedlist(unchanged)
> Scene 2 / Value for Vanes U-D (if available)list(unchanged)
> Scene 2 / Value for Vanes L-R (if available)list(unchanged)
> Scene 2 / Value for Setpoint Templist(unchanged)
> Scene 2 / Value for Remote Locklist(unchanged)
Scene 3 presetlistNo
> Scene 3 / Value for ON/OFFlist(unchanged)
> Scene 3 / Value for Modelist(unchanged)
> Scene 3 / Value for Fan Speedlist(unchanged)
> Scene 3 / Value for Vanes U-D (if available)list(unchanged)
> Scene 3 / Value for Vanes L-R (if available)list(unchanged)
> Scene 3 / Value for Setpoint Templist(unchanged)
> Scene 3 / Value for Remote Locklist(unchanged)
Scene 4 presetlistNo
> Scene 4 / Value for ON/OFFlist(unchanged)
> Scene 4 / Value for Modelist(unchanged)
> Scene 4 / Value for Fan Speedlist(unchanged)
> Scene 4 / Value for Vanes U-D (if available)list(unchanged)
> Scene 4 / Value for Vanes L-R (if available)list(unchanged)
> Scene 4 / Value for Setpoint Templist(unchanged)
> Scene 4 / Value for Remote Locklist(unchanged)
Scene 5 presetlistNo
> Scene 5 / Value for ON/OFFlist(unchanged)
> Scene 5 / Value for Modelist(unchanged)
> Scene 5 / Value for Fan Speedlist(unchanged)
> Scene 5 / Value for Vanes U-D (if available)list(unchanged)
> Scene 5 / Value for Vanes L-R (if available)list(unchanged)
> Scene 5 / Value for Setpoint Templist(unchanged)
> Scene 5 / Value for Remote Locklist(unchanged)
Enable use of Open Window / Switch off timeout functionlistNo
> AC switch-off timeout (minutes)unsignedInt 0…3010
> Datapoint typelist0 = Stop / 1 = Start Timeout [DPT_1.010]
> Reload last On/Off value once window is closedlistNo
Enable use of Occupancy functionlistNo
> Timeout to apply action (minutes)unsignedInt 0…18020
> Action after timeout elapsedlistSwitch-Off AC
> Setpoint delta decrease (HEAT) or increase (COOL)list2.0 ºC
> Enable secondary timeoutlistNo
> Timeout to apply action (min)unsignedInt 1…18020
> Setpoint delta decrease (HEAT) or increase (COOL)list2.0 ºC
Enable object "Error Text Code" (3 ASCII-char Error Code)listYes
Indoor unit has HEAT mode (see documentation of indoor unit)listYes
> Disallow On/Off operation while window is openlistNo
> Disallow On/Off operation while timeout is elapsedlistNo
> Reload last On/Off value once timeout is stoppedlistNo
> Disallow On/Off operation while not occupiedlistNo
> Reload last On/Off value when occupiedlistNo
> Debounce timelist50 ms
> Contact typelistNO: Normally Open
> Lock functionlistNo
> FunctionlistSwitch
> Sending delay after bus recovery (seconds)unsignedInt 0…25510
> Send telegram after bus recoverylistNo action
Indoor unit has FAN mode (see documentation of indoor unit)listYes
> Value on rising edge (contact activated)listNo action
> Value on falling edge (contact deactivated)listNo action
> Send cyclically every (seconds)unsignedInt 1…6553510
> Cyclical sendinglistNever
> Scene when contact is activated (needs to be defined)listScene 1
> Setpoint temperaturelist20.0 ºC
> Setpoint temperaturelist30.0 ºC
Enable use of Input 1listNo
Enable use of Input 2listNo
Enable use of Input 3listNo
Enable use of Input 4listNo
> Reset Input when enablinglistNo
> Mode for short (long) operationlistToggle: ON/OFF (increase/decrease)
> Increasing steplist+ 25 %
> Decreasing steplist- 25 %
> Short/long operation limit (x 100 ms)unsignedInt 1…25510
> Cycle time to send in long operation (x 100 ms) (0 = not active)unsignedInt 0…2550
> OperationlistToggle (Up/Down)
> MethodlistStep-Move-Step
> Vanes adjustment time (x 100 ms)unsignedInt 1…25510
> Datapoint type to be sentlistDPT 5.010 (1 Byte)
> Value on rising edge (when contact activated)unsignedInt 0…2550
> Value on rising edge (when contact activated)unsignedInt 0…655350
> Value on rising edge (when contact activated)signedInt -32768…327670
> Value on rising edge (x 0.1 ºC) (when contact activated)signedInt -2730…3276250
> Value on rising edge (when contact activated)unsignedInt 0…42949672950
Enable use of Power ConsumptionlistNo
> Power threshold to update (W)unsignedInt 0…25550
> Power update timeout (s)unsignedInt 0…25530
> Energy update timeout (min)unsignedInt 0…2551
Etherea AC modellistCS-xyyMKE or CS-xyyNKE
Power consumption is not available for current AC model:textCS-xyyMKE or CS-xyyNKE

Version history

ApplicationApp noFingerprintFirst seenSizeFile
KNX Gateway for Panasonic Etherea air conditioning units, flush mounted 1.5 latest$0483A2642026-11-25196 KBDownload

About this file

This is the official ETS product database for the MDT technologies GmbH KNX Gateway for Panasonic Etherea air conditioning units, flush mounted (SCN-ACG0PAN.01), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from MDT technologies GmbH

All MDT technologies GmbH products