L&J secure heat meter WMZC 30 WMZC-SEC
Lingg & Janke · Order number WMZC-SEC · counters / meters › L&J secure heat meters
Download .knxprod SEC heat meter WMZC F006-30 3.0 · 132 KB
Product
| Manufacturer | Lingg & Janke |
|---|---|
| Product name | L&J secure heat meter WMZC 30 |
| Order number | WMZC-SEC |
| Product text | L&J secure heat meter WMZC |
| Hardware | WMZC-SEC |
| Medium | Twisted Pair |
| Bus current (mA) | 10 |
| Rail mounted | No |
| Registration | Registered · 2021-06-30 |
| Languages | en-US, de-DE |
| Catalog entry | M-00E1_H-15006.2D10-1_HP-F006-30-B097_CI-WMZC.2DSEC-1 |
| Fingerprint | B097 |
| SHA-256 | 407efb80a0585c64a7cb9ab912f7543335edc33bec41c9cac6a6afd43ca64be8 |
| First seen | 2026-11-25 |
| Markets | 69 markets |
Application program: SEC heat meter WMZC F006-30 3.0
| Application number | $F006 |
|---|---|
| Version | 3.0 |
| Mask version | MV-0021 (2.1) |
| KNX Data Secure | Yes |
| Minimum ETS version | 5.0 |
| Parameters | 362 |
| Group objects | 35 |
Group objects (35)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | output 4byte EIS11 | serial number | 4 Bytes | DPT.12 | CT |
| 1 | output 4byte EIS11 | meter number | 4 Bytes | DPT.12 | CT |
| 2 | output 1bit EIS1 | status | 1 Bit | 1.11 state | CT |
| 3 | input 1bit EIS1 | read meters | 1 Bit | 1.17 trigger | CWU |
| 4 | output 4byte EIS11 | meter reading (MWh) | 4 Bytes | 13.16 active energy (MWh) | CT |
| 4 | output 4byte EIS11 | meter reading thermal e. (MWh) | 4 Bytes | 13.16 active energy (MWh) | CT |
| 5 | output 4byte EIS11 | meter reading (kWh) | 4 Bytes | 13.13 active energy (kWh) | CT |
| 5 | output 4byte EIS11 | meter reading thermal e. (kWh) | 4 Bytes | 13.13 active energy (kWh) | CT |
| 6 | output 4byte EIS11 | 15min. diff. (kWh) | 4 Bytes | 13.13 active energy (kWh) | CT |
| 7 | output 4byte EIS11 | 60min. diff. (kWh) | 4 Bytes | 13.13 active energy (kWh) | CT |
| 8 | output 4byte EIS11 | rel. counter (MWh) | 4 Bytes | 13.16 active energy (MWh) | CT |
| 9 | input 1bit EIS1 | reset rel. counter | 1 Bit | 1.15 reset | CWU |
| 10 | output 4byte EIS11 | rel. reverse counter (MWh) | 4 Bytes | 13.16 active energy (MWh) | CT |
| 11 | input 4byte EIS11 | set rel. reverse counter | 4 Bytes | 13.16 active energy (MWh) | CWU |
| 12 | output 1bit EIS1 | rel. reverse counter is zero | 1 Bit | 1.2 boolean | CT |
| 16 | output 4byte EIS11 | volume (m3) | 4 Bytes | 12.1201 volume (m³) | CT |
| 17 | output 4byte EIS11 | volume (l) | 4 Bytes | 12.1200 volume liquid (l) | CT |
| 18 | output 4byte EIS11 | meter reading cooling e. (MWh) | 4 Bytes | 13.16 active energy (MWh) | CT |
| 19 | output 4byte EIS11 | meter reading cooling e. (kWh) | 4 Bytes | 13.13 active energy (kWh) | CT |
| 61 | output 4byte EIS9 | power (W) | 4 Bytes | 14.56 power (W) | CT |
| 62 | output 1bit EIS1 | upper switch point power | 1 Bit | 1.1 switch | CT |
| 63 | output 1bit EIS1 | lower switch point power | 1 Bit | 1.1 switch | CT |
| 82 | output 4byte EIS9 | flow (m3/h) | 4 Bytes | 14.1200 volume flux for meters (m³/h) | CT |
| 83 | output 1bit EIS1 | upper switch point flow | 1 Bit | 1.1 switch | CT |
| 84 | output 1bit EIS1 | lower switch point flow | 1 Bit | 1.1 switch | CT |
| 85 | output 4byte EIS11 | flow (0.0001 m3/h) | 4 Bytes | 13.2 flow rate (m³/h) | CT |
| 91 | output 4byte EIS9 | temperature forward flow (°C) | 2 Bytes | 9.1 temperature (°C) | CT |
| 92 | output 1bit EIS1 | upper switch point temp. forw. | 1 Bit | 1.1 switch | CT |
| 93 | output 1bit EIS1 | lower switch point temp. forw. | 1 Bit | 1.1 switch | CT |
| 94 | output 4byte EIS9 | temperature return flow (°C) | 2 Bytes | 9.1 temperature (°C) | CT |
| 95 | output 1bit EIS1 | upper switch point temp. ret. | 1 Bit | 1.1 switch | CT |
| 96 | output 1bit EIS1 | lower switch point temp. ret. | 1 Bit | 1.1 switch | CT |
| 97 | output 4byte EIS9 | temperature difference (K) | 2 Bytes | 9.2 temperature difference (K) | CT |
| 98 | output 1bit EIS1 | upper switch point temp. diff. | 1 Bit | 1.1 switch | CT |
| 99 | output 1bit EIS1 | lower switch point temp. diff. | 1 Bit | 1.1 switch | CT |
Parameters (36)
| Parameter | Type | Default |
|---|---|---|
| type of meter | list | Type 1 meter |
| show meter readings | list | yes |
| send meter readings | list | cyclic |
| cycle time in s (5..65535) | unsignedInt 5…65535 | 300 |
| show meter readings (high resolution) | list | no |
| send meter readings (high resolution) | list | cyclic |
| show meter status | list | no |
| show serial number | list | no |
| send meter status and serial number cyclically | list | no |
| show 15 min. and 60 min. meter differences | list | no |
| show relative forward meter | list | no |
| show relative reverse meter | list | no |
| send relative meters | list | cyclic |
| show power | list | no |
| send power cyclically | list | yes |
| power limit monitoring | list | no |
| action at upper limit | list | do nothing |
| upper limit in W (1..65000) | unsignedInt 1…65000 | 1100 |
| action at lower limit | list | do nothing |
| lower limit in W (1..65000) | unsignedInt 1…65000 | 900 |
| show flow | list | no |
| send flow cyclically | list | yes |
| show flow as integer (resolution 0.0001 m3/h) | list | no |
| flow limit monitoring | list | no |
| upper limit in l/h (1/1000 m3/h) (1..65000) | unsignedInt 1…65000 | 1100 |
| lower limit in l/h (1/1000 m3/h) (1..65000) | unsignedInt 1…65000 | 900 |
| show temperature | list | no |
| send temperature cyclically | list | yes |
| temperature forward limit monitoring | list | no |
| temperature return limit monitoring | list | no |
| temperature difference limit monitoring | list | no |
| upper limit in °C (1..100) | unsignedInt 1…100 | 80 |
| lower limit in °C (1..100) | unsignedInt 1…100 | 60 |
| upper limit in K (1..100) | unsignedInt 1…100 | 20 |
| lower limit in K (1..100) | unsignedInt 1…100 | 5 |
| meter value refresh time in s (5..900) | unsignedInt 5…900 | 5 |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| SEC heat meter WMZC F006-30 3.0 latest | $F006 | B097 | 2026-11-25 | 132 KB | Download |
About this file
This is the official ETS product database for the Lingg & Janke L&J secure heat meter WMZC 30 (WMZC-SEC), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from Lingg & Janke
- electricity meter EZD FacilityWeb 22 EZD-FW-22
- L&J secure electricity meter EZD 30 EZD-SEC
- gas meter GZC FacilityWeb GZC-FW
- L&J secure gas meter GZC 30 GZC-SEC
- water meter KWZC FacilityWeb KWZC-FW
- L&J secure water meter KWZC 30 KWZC-SEC
- heat meter WMZC FacilityWeb WMZC-FW
- AH3F16H-SEC switching actuator 3fold 79236-SEC
- AH5F16H-SEC switching actuator 5fold 79237-SEC
- AH9F16H-SEC switching actuator 9fold 79238-SEC
- COMIP-REG-1-SEC secure IP interface 87342-SEC
- TA4F55-BUDGET-SEC push button 4fold 87840-SEC