| 0 | Display | Day/night | 1 Bit | | CW |
| 1 | Display | Backlight | 1 Bit | 1.1 switch | CW |
| 2 | Display | Display luminosity | 1 Byte | 5.1 percentage (0..100%) | CW |
| 3 | Display | Predefined user text message 1 | 1 Bit | 1.1 switch | CW |
| 4 | Display | Predefined user text message 2 | 1 Bit | 1.1 switch | CW |
| 5 | Display | Predefined user text message 3 | 1 Bit | 1.1 switch | CW |
| 6 | Display | Alarm message | 14 Bytes | 16.0 Character String (ASCII) | CW |
| 7 | Display | Reset alarm message | 1 Bit | 1.15 reset | CW |
| 8 | Display | Lock-up | 1 Bit | 1.1 switch | CW |
| 9 | Display | Home status - 1 bit | 1 Bit | 1.1 switch | CW |
| 10 | Display | Home status - 1 byte | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 11 | Display | Home status - 2 bytes | 2 Bytes | 7.1 pulses | CW |
| 12 | Display | Home status - 4 bytes | 4 Bytes | 12.1 counter pulses (unsigned) | CW |
| 13 | Thermostat | Mode selection | 1 Byte | 20.102 HVAC mode | CW |
| 14 | Thermostat | Comfort mode | 1 Bit | 1.1 switch | CW |
| 15 | Thermostat | Standby mode | 1 Bit | 1.1 switch | CW |
| 16 | Thermostat | Night mode | 1 Bit | 1.1 switch | CW |
| 17 | Thermostat | Frost/heat protection mode | 1 Bit | 1.1 switch | CW |
| 18 | Thermostat | Setpoint selection automatic control | 1 Byte | 20.102 HVAC mode | CW |
| 19 | Thermostat | Automatic control deactivation | 1 Bit | 1.3 enable | CW |
| 20 | Thermostat | Heating/Cooling - changeover | 1 Bit | 1.100 heating/cooling | CW |
| 21 | Thermostat | Priority | 2 Bit | 2.2 boolean control | CW |
| 22 | Thermostat | Windows contact | 1 Bit | 1.19 window/door | CW |
| 23 | Thermostat | Overload | 1 Bit | 1.2 boolean | CW |
| 24 | Thermostat | Scene | 1 Byte | 18.1 scene control | CW |
| 25 | Thermostat | Holiday mode | 1 Bit | 1.10 start/stop | CW |
| 26 | Thermostat | Status indication mode selection | 1 Byte | 20.102 HVAC mode | CRT |
| 27 | Thermostat | Automatic control deactivation status | 1 Bit | 1.3 enable | CRT |
| 28 | Thermostat | Heating/Cooling - status indication | 1 Bit | 1.100 heating/cooling | CRT |
| 29 | Thermostat | Status indication heating active | 1 Bit | 1.11 state | CRT |
| 30 | Thermostat | Status indication cooling active | 1 Bit | 1.11 state | CRT |
| 31 | Thermostat | Status indication priority | 1 Bit | 1.11 state | CRT |
| 32 | Thermostat | ON/OFF - basic heating | 1 Bit | 1.1 switch | CRT |
| 33 | Thermostat | Valve position in % - basic heating | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 34 | Thermostat | ON/OFF - basic cooling | 1 Bit | 1.1 switch | CRT |
| 35 | Thermostat | Valve position in % - basic cooling | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 36 | Thermostat | ON/OFF - additional heating | 1 Bit | 1.1 switch | CRT |
| 37 | Thermostat | Valve position in % - additional heating | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 38 | Thermostat | ON/OFF - additional cooling | 1 Bit | 1.1 switch | CRT |
| 39 | Thermostat | Valve position in % - additional cooling | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 40 | Thermostat | Outdoor temperature | 2 Bytes | 9.1 temperature (°C) | CW |
| 41 | Thermostat | Room temperature | 2 Bytes | 9.1 temperature (°C) | CW |
| 42 | Thermostat | Floor temperature | 2 Bytes | 9.1 temperature (°C) | CW |
| 43 | Thermostat | Status indication room temperature | 2 Bytes | 9.1 temperature (°C) | CRT |
| 44 | Thermostat | Minimum room temperature alarm | 1 Bit | 1.5 alarm | CRT |
| 45 | Thermostat | Maximum room temperature alarm | 1 Bit | 1.5 alarm | CRT |
| 46 | Thermostat | Ventilation automatic/manual mode | 1 Bit | 1.1 switch | CW |
| 47 | Thermostat | Status ventilation step 1-6 | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 48 | Thermostat | Status ventilation step 1 | 1 Bit | 1.1 switch | CW |
| 49 | Thermostat | Status ventilation step 2 | 1 Bit | 1.1 switch | CW |
| 50 | Thermostat | Status ventilation step 3 | 1 Bit | 1.1 switch | CW |
| 51 | Thermostat | Status ventilation step 4 | 1 Bit | 1.1 switch | CW |
| 52 | Thermostat | Status ventilation step 5 | 1 Bit | 1.1 switch | CW |
| 53 | Thermostat | Status ventilation step 6 | 1 Bit | 1.1 switch | CW |
| 54 | Thermostat | Ventilation step 1-6 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 55 | Thermostat | Ventilation step 1 | 1 Bit | 1.1 switch | CRT |
| 56 | Thermostat | Ventilation step 2 | 1 Bit | 1.1 switch | CRT |
| 57 | Thermostat | Ventilation step 3 | 1 Bit | 1.1 switch | CRT |
| 58 | Thermostat | Ventilation step 4 | 1 Bit | 1.1 switch | CRT |
| 59 | Thermostat | Ventilation step 5 | 1 Bit | 1.1 switch | CRT |
| 60 | Thermostat | Ventilation step 6 | 1 Bit | 1.1 switch | CRT |
| 61 | Thermostat | Ventilation step 1-6 extension | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 62 | Thermostat | Status ventilation step 1-6 extension | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 63 | Thermostat | Comfort setpoint heating | 2 Bytes | 9.1 temperature (°C) | CW |
| 64 | Thermostat | Standby setpoint heating | 2 Bytes | 9.1 temperature (°C) | CW |
| 65 | Thermostat | Night setpoint heating | 2 Bytes | 9.1 temperature (°C) | CW |
| 66 | Thermostat | Frost protection setpoint heating | 2 Bytes | 9.1 temperature (°C) | CW |
| 67 | Thermostat | Setpoints heating | 8 Bytes | | CW |
| 68 | Thermostat | Comfort setpoint cooling | 2 Bytes | 9.1 temperature (°C) | CW |
| 69 | Thermostat | Standby setpoint cooling | 2 Bytes | 9.1 temperature (°C) | CW |
| 70 | Thermostat | Night setpoint cooling | 2 Bytes | 9.1 temperature (°C) | CW |
| 71 | Thermostat | Heat protection setpoint cooling | 2 Bytes | 9.1 temperature (°C) | CW |
| 72 | Thermostat | Setpoints cooling | 8 Bytes | | CW |
| 73 | Thermostat | Override setpoint | 2 Bytes | 9.2 temperature difference (K) | CW |
| 74 | Thermostat | Override setpoint status | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 75 | Thermostat | Status indication comfort setpoint heating | 2 Bytes | 9.1 temperature (°C) | CRT |
| 76 | Thermostat | Status indication standby setpoint heating | 2 Bytes | 9.1 temperature (°C) | CRT |
| 77 | Thermostat | Status indication night setpoint heating | 2 Bytes | 9.1 temperature (°C) | CRT |
| 78 | Thermostat | Status indication frost protection setpoint heating | 2 Bytes | 9.1 temperature (°C) | CRT |
| 79 | Thermostat | Status indication setpoints heating | 8 Bytes | | CRT |
| 80 | Thermostat | Status indication comfort setpoint cooling | 2 Bytes | 9.1 temperature (°C) | CRT |
| 81 | Thermostat | Status indication standby setpoint cooling | 2 Bytes | 9.1 temperature (°C) | CRT |
| 82 | Thermostat | Status indication night setpoint cooling | 2 Bytes | 9.1 temperature (°C) | CRT |
| 83 | Thermostat | Status indication heat protection setpoint cooling | 2 Bytes | 9.1 temperature (°C) | CRT |
| 84 | Thermostat | Status indication setpoints cooling | 8 Bytes | | CRT |
| 85 | Thermostat | Status indication current setpoint | 2 Bytes | 9.1 temperature (°C) | CRT |
| 86 | Thermostat | Presence | 1 Bit | 1.1 switch | CW |
| 87 | Thermostat | Thermostat deactivation | 1 Bit | 1.3 enable | CW |
| 88 | Thermostat | Lock-up additional step | 1 Bit | 1.1 switch | CW |
| 89 | Temperature | Internal temperature sensor | 2 Bytes | 9.1 temperature (°C) | CRT |
| 90 | Temperature | External temperature sensor | 2 Bytes | 9.1 temperature (°C) | CRT |
| 91 | Date and time | Date | 3 Bytes | 11.1 date | CW |
| 92 | Date and time | Time | 3 Bytes | 10.1 time of day | CW |
| 93 | Date and time | Date and time | 8 Bytes | 19.1 date time | CWI |
| 94 | Date and time | Date and time request | 1 Bit | 1.17 trigger | CRT |
| 95 | Push-button 1 | Automatic control deactivation status | 1 Bit | 1.3 enable | CRWTU |
| 95 | Push-button 1 | Heating/Cooling - status indication | 1 Bit | 1.100 heating/cooling | CRWTU |
| 95 | Push-button 1 | Status indication ON/OFF | 1 Bit | 1.1 switch | CRWTU |
| 95 | Push-button 1 | Status indication priority | 1 Bit | 1.11 state | CRWTU |
| 95 | Push-button 1 | Upper position reached | 1 Bit | 1.2 boolean | CRWTU |
| 96 | Push-button 1 | Lower position reached | 1 Bit | 1.2 boolean | CRWTU |
| 97 | Push-button 1 | Status ind. brightness value | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 97 | Push-button 1 | Status indication setpoint selection | 1 Byte | 20.102 HVAC mode | CRWTU |
| 97 | Push-button 1 | Status indication position in % | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 98 | Push-button 1 | Slat angle indication in % | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 99 | Push-button 1 | Override setpoint status | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 100 | Push-button 1 | Automatic control deactivation | 1 Bit | 1.3 enable | CRT |
| 100 | Push-button 1 | Heating/Cooling - changeover | 1 Bit | 1.100 heating/cooling | CRT |
| 100 | Push-button 1 | ON/OFF | 1 Bit | 1.1 switch | CRT |
| 100 | Push-button 1 | Timer | 1 Bit | 1.10 start/stop | CRT |
| 100 | Push-button 1 | Up/down | 1 Bit | 1.8 up/down | CRT |
| 101 | Push-button 1 | Step/stop (short press) | 1 Bit | 1.7 step | CRT |
| 101 | Push-button 1 | Stop (short press) | 1 Bit | 1.17 trigger | CRT |
| 102 | Push-button 1 | Priority | 2 Bit | 2.2 boolean control | CRT |
| 103 | Push-button 1 | Dimming | 4 Bit | 3.7 dimming control | CRT |
| 104 | Push-button 1 | Value (0-255) | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 104 | Push-button 1 | Brightness value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 104 | Push-button 1 | Setpoint selection | 1 Byte | 20.102 HVAC mode | CRT |
| 104 | Push-button 1 | Position in % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 104 | Push-button 1 | Scene | 1 Byte | 18.1 scene control | CRT |
| 105 | Push-button 1 | Slat angle in % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 106 | Push-button 1 | Value (0-65535) | 2 Bytes | 7.1 pulses | CRT |
| 106 | Push-button 1 | Override setpoint | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 107 | Push-button 2 | Automatic control deactivation status | 1 Bit | 1.3 enable | CRWTU |
| 107 | Push-button 2 | Heating/Cooling - status indication | 1 Bit | 1.100 heating/cooling | CRWTU |
| 107 | Push-button 2 | Status indication ON/OFF | 1 Bit | 1.1 switch | CRWTU |
| 107 | Push-button 2 | Status indication priority | 1 Bit | 1.11 state | CRWTU |
| 107 | Push-button 2 | Upper position reached | 1 Bit | 1.2 boolean | CRWTU |
| 108 | Push-button 2 | Lower position reached | 1 Bit | 1.2 boolean | CRWTU |
| 109 | Push-button 2 | Status ind. brightness value | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 109 | Push-button 2 | Status indication setpoint selection | 1 Byte | 20.102 HVAC mode | CRWTU |
| 109 | Push-button 2 | Status indication position in % | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 110 | Push-button 2 | Slat angle indication in % | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 111 | Push-button 2 | Override setpoint status | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 112 | Push-button 2 | Automatic control deactivation | 1 Bit | 1.3 enable | CRT |
| 112 | Push-button 2 | Heating/Cooling - changeover | 1 Bit | 1.100 heating/cooling | CRT |
| 112 | Push-button 2 | ON/OFF | 1 Bit | 1.1 switch | CRT |
| 112 | Push-button 2 | Timer | 1 Bit | 1.10 start/stop | CRT |
| 112 | Push-button 2 | Up/down | 1 Bit | 1.8 up/down | CRT |
| 113 | Push-button 2 | Step/stop (short press) | 1 Bit | 1.7 step | CRT |
| 113 | Push-button 2 | Stop (short press) | 1 Bit | 1.17 trigger | CRT |
| 114 | Push-button 2 | Priority | 2 Bit | 2.2 boolean control | CRT |
| 115 | Push-button 2 | Dimming | 4 Bit | 3.7 dimming control | CRT |
| 116 | Push-button 2 | Value (0-255) | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 116 | Push-button 2 | Brightness value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 116 | Push-button 2 | Setpoint selection | 1 Byte | 20.102 HVAC mode | CRT |
| 116 | Push-button 2 | Position in % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 116 | Push-button 2 | Scene | 1 Byte | 18.1 scene control | CRT |
| 117 | Push-button 2 | Slat angle in % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 118 | Push-button 2 | Value (0-65535) | 2 Bytes | 7.1 pulses | CRT |
| 118 | Push-button 2 | Override setpoint | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 119 | Push-button 3 | Automatic control deactivation status | 1 Bit | 1.3 enable | CRWTU |
| 119 | Push-button 3 | Heating/Cooling - status indication | 1 Bit | 1.100 heating/cooling | CRWTU |
| 119 | Push-button 3 | Status indication ON/OFF | 1 Bit | 1.1 switch | CRWTU |
| 119 | Push-button 3 | Status indication priority | 1 Bit | 1.11 state | CRWTU |
| 119 | Push-button 3 | Upper position reached | 1 Bit | 1.2 boolean | CRWTU |
| 120 | Push-button 3 | Lower position reached | 1 Bit | 1.2 boolean | CRWTU |
| 121 | Push-button 3 | Status ind. brightness value | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 121 | Push-button 3 | Status indication setpoint selection | 1 Byte | 20.102 HVAC mode | CRWTU |
| 121 | Push-button 3 | Status indication position in % | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 122 | Push-button 3 | Slat angle indication in % | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 123 | Push-button 3 | Override setpoint status | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 124 | Push-button 3 | Automatic control deactivation | 1 Bit | 1.3 enable | CRT |
| 124 | Push-button 3 | Heating/Cooling - changeover | 1 Bit | 1.100 heating/cooling | CRT |
| 124 | Push-button 3 | ON/OFF | 1 Bit | 1.1 switch | CRT |
| 124 | Push-button 3 | Timer | 1 Bit | 1.10 start/stop | CRT |
| 124 | Push-button 3 | Up/down | 1 Bit | 1.8 up/down | CRT |
| 125 | Push-button 3 | Step/stop (short press) | 1 Bit | 1.7 step | CRT |
| 125 | Push-button 3 | Stop (short press) | 1 Bit | 1.17 trigger | CRT |
| 126 | Push-button 3 | Priority | 2 Bit | 2.2 boolean control | CRT |
| 127 | Push-button 3 | Dimming | 4 Bit | 3.7 dimming control | CRT |
| 128 | Push-button 3 | Value (0-255) | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 128 | Push-button 3 | Brightness value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 128 | Push-button 3 | Setpoint selection | 1 Byte | 20.102 HVAC mode | CRT |
| 128 | Push-button 3 | Position in % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 128 | Push-button 3 | Scene | 1 Byte | 18.1 scene control | CRT |
| 129 | Push-button 3 | Slat angle in % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 130 | Push-button 3 | Value (0-65535) | 2 Bytes | 7.1 pulses | CRT |
| 130 | Push-button 3 | Override setpoint | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 131 | Push-button 4 | Automatic control deactivation status | 1 Bit | 1.3 enable | CRWTU |
| 131 | Push-button 4 | Heating/Cooling - status indication | 1 Bit | 1.100 heating/cooling | CRWTU |
| 131 | Push-button 4 | Status indication ON/OFF | 1 Bit | 1.1 switch | CRWTU |
| 131 | Push-button 4 | Status indication priority | 1 Bit | 1.11 state | CRWTU |
| 131 | Push-button 4 | Upper position reached | 1 Bit | 1.2 boolean | CRWTU |
| 132 | Push-button 4 | Lower position reached | 1 Bit | 1.2 boolean | CRWTU |
| 133 | Push-button 4 | Status ind. brightness value | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 133 | Push-button 4 | Status indication setpoint selection | 1 Byte | 20.102 HVAC mode | CRWTU |
| 133 | Push-button 4 | Status indication position in % | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 134 | Push-button 4 | Slat angle indication in % | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 135 | Push-button 4 | Override setpoint status | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 136 | Push-button 4 | Automatic control deactivation | 1 Bit | 1.3 enable | CRT |
| 136 | Push-button 4 | Heating/Cooling - changeover | 1 Bit | 1.100 heating/cooling | CRT |
| 136 | Push-button 4 | ON/OFF | 1 Bit | 1.1 switch | CRT |
| 136 | Push-button 4 | Timer | 1 Bit | 1.10 start/stop | CRT |
| 136 | Push-button 4 | Up/down | 1 Bit | 1.8 up/down | CRT |
| 137 | Push-button 4 | Step/stop (short press) | 1 Bit | 1.7 step | CRT |
| 137 | Push-button 4 | Stop (short press) | 1 Bit | 1.17 trigger | CRT |
| 138 | Push-button 4 | Priority | 2 Bit | 2.2 boolean control | CRT |
| 139 | Push-button 4 | Dimming | 4 Bit | 3.7 dimming control | CRT |
| 140 | Push-button 4 | Value (0-255) | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 140 | Push-button 4 | Brightness value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 140 | Push-button 4 | Setpoint selection | 1 Byte | 20.102 HVAC mode | CRT |
| 140 | Push-button 4 | Position in % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 140 | Push-button 4 | Scene | 1 Byte | 18.1 scene control | CRT |
| 141 | Push-button 4 | Slat angle in % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 142 | Push-button 4 | Value (0-65535) | 2 Bytes | 7.1 pulses | CRT |
| 142 | Push-button 4 | Override setpoint | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 143 | Push-button 5 | Automatic control deactivation status | 1 Bit | 1.3 enable | CRWTU |
| 143 | Push-button 5 | Heating/Cooling - status indication | 1 Bit | 1.100 heating/cooling | CRWTU |
| 143 | Push-button 5 | Status indication ON/OFF | 1 Bit | 1.1 switch | CRWTU |
| 143 | Push-button 5 | Status indication priority | 1 Bit | 1.11 state | CRWTU |
| 143 | Push-button 5 | Upper position reached | 1 Bit | 1.2 boolean | CRWTU |
| 144 | Push-button 5 | Lower position reached | 1 Bit | 1.2 boolean | CRWTU |
| 145 | Push-button 5 | Status ind. brightness value | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 145 | Push-button 5 | Status indication setpoint selection | 1 Byte | 20.102 HVAC mode | CRWTU |
| 145 | Push-button 5 | Status indication position in % | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 146 | Push-button 5 | Slat angle indication in % | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 147 | Push-button 5 | Override setpoint status | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 148 | Push-button 5 | Automatic control deactivation | 1 Bit | 1.3 enable | CRT |
| 148 | Push-button 5 | Heating/Cooling - changeover | 1 Bit | 1.100 heating/cooling | CRT |
| 148 | Push-button 5 | ON/OFF | 1 Bit | 1.1 switch | CRT |
| 148 | Push-button 5 | Timer | 1 Bit | 1.10 start/stop | CRT |
| 148 | Push-button 5 | Up/down | 1 Bit | 1.8 up/down | CRT |
| 149 | Push-button 5 | Step/stop (short press) | 1 Bit | 1.7 step | CRT |
| 149 | Push-button 5 | Stop (short press) | 1 Bit | 1.17 trigger | CRT |
| 150 | Push-button 5 | Priority | 2 Bit | 2.2 boolean control | CRT |
| 151 | Push-button 5 | Dimming | 4 Bit | 3.7 dimming control | CRT |
| 152 | Push-button 5 | Value (0-255) | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 152 | Push-button 5 | Brightness value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 152 | Push-button 5 | Setpoint selection | 1 Byte | 20.102 HVAC mode | CRT |
| 152 | Push-button 5 | Position in % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 152 | Push-button 5 | Scene | 1 Byte | 18.1 scene control | CRT |
| 153 | Push-button 5 | Slat angle in % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 154 | Push-button 5 | Value (0-65535) | 2 Bytes | 7.1 pulses | CRT |
| 154 | Push-button 5 | Override setpoint | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 155 | Push-button 6 | Automatic control deactivation status | 1 Bit | 1.3 enable | CRWTU |
| 155 | Push-button 6 | Heating/Cooling - status indication | 1 Bit | 1.100 heating/cooling | CRWTU |
| 155 | Push-button 6 | Status indication ON/OFF | 1 Bit | 1.1 switch | CRWTU |
| 155 | Push-button 6 | Status indication priority | 1 Bit | 1.11 state | CRWTU |
| 155 | Push-button 6 | Upper position reached | 1 Bit | 1.2 boolean | CRWTU |
| 156 | Push-button 6 | Lower position reached | 1 Bit | 1.2 boolean | CRWTU |
| 157 | Push-button 6 | Status ind. brightness value | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 157 | Push-button 6 | Status indication setpoint selection | 1 Byte | 20.102 HVAC mode | CRWTU |
| 157 | Push-button 6 | Status indication position in % | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 158 | Push-button 6 | Slat angle indication in % | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 159 | Push-button 6 | Override setpoint status | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 160 | Push-button 6 | Automatic control deactivation | 1 Bit | 1.3 enable | CRT |
| 160 | Push-button 6 | Heating/Cooling - changeover | 1 Bit | 1.100 heating/cooling | CRT |
| 160 | Push-button 6 | ON/OFF | 1 Bit | 1.1 switch | CRT |
| 160 | Push-button 6 | Timer | 1 Bit | 1.10 start/stop | CRT |
| 160 | Push-button 6 | Up/down | 1 Bit | 1.8 up/down | CRT |
| 161 | Push-button 6 | Step/stop (short press) | 1 Bit | 1.7 step | CRT |
| 161 | Push-button 6 | Stop (short press) | 1 Bit | 1.17 trigger | CRT |
| 162 | Push-button 6 | Priority | 2 Bit | 2.2 boolean control | CRT |
| 163 | Push-button 6 | Dimming | 4 Bit | 3.7 dimming control | CRT |
| 164 | Push-button 6 | Value (0-255) | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 164 | Push-button 6 | Brightness value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 164 | Push-button 6 | Setpoint selection | 1 Byte | 20.102 HVAC mode | CRT |
| 164 | Push-button 6 | Position in % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 164 | Push-button 6 | Scene | 1 Byte | 18.1 scene control | CRT |
| 165 | Push-button 6 | Slat angle in % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 166 | Push-button 6 | Value (0-65535) | 2 Bytes | 7.1 pulses | CRT |
| 166 | Push-button 6 | Override setpoint | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 167 | Push-button 7 | Automatic control deactivation status | 1 Bit | 1.3 enable | CRWTU |
| 167 | Push-button 7 | Heating/Cooling - status indication | 1 Bit | 1.100 heating/cooling | CRWTU |
| 167 | Push-button 7 | Status indication ON/OFF | 1 Bit | 1.1 switch | CRWTU |
| 167 | Push-button 7 | Status indication priority | 1 Bit | 1.11 state | CRWTU |
| 167 | Push-button 7 | Upper position reached | 1 Bit | 1.2 boolean | CRWTU |
| 168 | Push-button 7 | Lower position reached | 1 Bit | 1.2 boolean | CRWTU |
| 169 | Push-button 7 | Status ind. brightness value | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 169 | Push-button 7 | Status indication setpoint selection | 1 Byte | 20.102 HVAC mode | CRWTU |
| 169 | Push-button 7 | Status indication position in % | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 170 | Push-button 7 | Slat angle indication in % | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 171 | Push-button 7 | Override setpoint status | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 172 | Push-button 7 | Automatic control deactivation | 1 Bit | 1.3 enable | CRT |
| 172 | Push-button 7 | Heating/Cooling - changeover | 1 Bit | 1.100 heating/cooling | CRT |
| 172 | Push-button 7 | ON/OFF | 1 Bit | 1.1 switch | CRT |
| 172 | Push-button 7 | Timer | 1 Bit | 1.10 start/stop | CRT |
| 172 | Push-button 7 | Up/down | 1 Bit | 1.8 up/down | CRT |
| 173 | Push-button 7 | Step/stop (short press) | 1 Bit | 1.7 step | CRT |
| 173 | Push-button 7 | Stop (short press) | 1 Bit | 1.17 trigger | CRT |
| 174 | Push-button 7 | Priority | 2 Bit | 2.2 boolean control | CRT |
| 175 | Push-button 7 | Dimming | 4 Bit | 3.7 dimming control | CRT |
| 176 | Push-button 7 | Value (0-255) | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 176 | Push-button 7 | Brightness value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 176 | Push-button 7 | Setpoint selection | 1 Byte | 20.102 HVAC mode | CRT |
| 176 | Push-button 7 | Position in % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 176 | Push-button 7 | Scene | 1 Byte | 18.1 scene control | CRT |
| 177 | Push-button 7 | Slat angle in % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 178 | Push-button 7 | Value (0-65535) | 2 Bytes | 7.1 pulses | CRT |
| 178 | Push-button 7 | Override setpoint | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 179 | Push-button 8 | Automatic control deactivation status | 1 Bit | 1.3 enable | CRWTU |
| 179 | Push-button 8 | Heating/Cooling - status indication | 1 Bit | 1.100 heating/cooling | CRWTU |
| 179 | Push-button 8 | Status indication ON/OFF | 1 Bit | 1.1 switch | CRWTU |
| 179 | Push-button 8 | Status indication priority | 1 Bit | 1.11 state | CRWTU |
| 179 | Push-button 8 | Upper position reached | 1 Bit | 1.2 boolean | CRWTU |
| 180 | Push-button 8 | Lower position reached | 1 Bit | 1.2 boolean | CRWTU |
| 181 | Push-button 8 | Status ind. brightness value | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 181 | Push-button 8 | Status indication setpoint selection | 1 Byte | 20.102 HVAC mode | CRWTU |
| 181 | Push-button 8 | Status indication position in % | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 182 | Push-button 8 | Slat angle indication in % | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 183 | Push-button 8 | Override setpoint status | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 184 | Push-button 8 | Automatic control deactivation | 1 Bit | 1.3 enable | CRT |
| 184 | Push-button 8 | Heating/Cooling - changeover | 1 Bit | 1.100 heating/cooling | CRT |
| 184 | Push-button 8 | ON/OFF | 1 Bit | 1.1 switch | CRT |
| 184 | Push-button 8 | Timer | 1 Bit | 1.10 start/stop | CRT |
| 184 | Push-button 8 | Up/down | 1 Bit | 1.8 up/down | CRT |
| 185 | Push-button 8 | Step/stop (short press) | 1 Bit | 1.7 step | CRT |
| 185 | Push-button 8 | Stop (short press) | 1 Bit | 1.17 trigger | CRT |
| 186 | Push-button 8 | Priority | 2 Bit | 2.2 boolean control | CRT |
| 187 | Push-button 8 | Dimming | 4 Bit | 3.7 dimming control | CRT |
| 188 | Push-button 8 | Value (0-255) | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 188 | Push-button 8 | Brightness value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 188 | Push-button 8 | Setpoint selection | 1 Byte | 20.102 HVAC mode | CRT |
| 188 | Push-button 8 | Position in % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 188 | Push-button 8 | Scene | 1 Byte | 18.1 scene control | CRT |
| 189 | Push-button 8 | Slat angle in % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 190 | Push-button 8 | Value (0-65535) | 2 Bytes | 7.1 pulses | CRT |
| 190 | Push-button 8 | Override setpoint | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 191 | Push-button 9 | Automatic control deactivation status | 1 Bit | 1.3 enable | CRWTU |
| 191 | Push-button 9 | Heating/Cooling - status indication | 1 Bit | 1.100 heating/cooling | CRWTU |
| 191 | Push-button 9 | Status indication ON/OFF | 1 Bit | 1.1 switch | CRWTU |
| 191 | Push-button 9 | Status indication priority | 1 Bit | 1.11 state | CRWTU |
| 191 | Push-button 9 | Upper position reached | 1 Bit | 1.2 boolean | CRWTU |
| 192 | Push-button 9 | Lower position reached | 1 Bit | 1.2 boolean | CRWTU |
| 193 | Push-button 9 | Status ind. brightness value | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 193 | Push-button 9 | Status indication setpoint selection | 1 Byte | 20.102 HVAC mode | CRWTU |
| 193 | Push-button 9 | Status indication position in % | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 194 | Push-button 9 | Slat angle indication in % | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 195 | Push-button 9 | Override setpoint status | 2 Bytes | 9.2 temperature difference (K) | CRWTU |
| 196 | Push-button 9 | Automatic control deactivation | 1 Bit | 1.3 enable | CRT |
| 196 | Push-button 9 | Heating/Cooling - changeover | 1 Bit | 1.100 heating/cooling | CRT |
| 196 | Push-button 9 | ON/OFF | 1 Bit | 1.1 switch | CRT |
| 196 | Push-button 9 | Timer | 1 Bit | 1.10 start/stop | CRT |
| 196 | Push-button 9 | Up/down | 1 Bit | 1.8 up/down | CRT |
| 197 | Push-button 9 | Step/stop (short press) | 1 Bit | 1.7 step | CRT |
| 197 | Push-button 9 | Stop (short press) | 1 Bit | 1.17 trigger | CRT |
| 198 | Push-button 9 | Priority | 2 Bit | 2.2 boolean control | CRT |
| 199 | Push-button 9 | Dimming | 4 Bit | 3.7 dimming control | CRT |
| 200 | Push-button 9 | Value (0-255) | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 200 | Push-button 9 | Brightness value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 200 | Push-button 9 | Setpoint selection | 1 Byte | 20.102 HVAC mode | CRT |
| 200 | Push-button 9 | Position in % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 200 | Push-button 9 | Scene | 1 Byte | 18.1 scene control | CRT |
| 201 | Push-button 9 | Slat angle in % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 202 | Push-button 9 | Value (0-65535) | 2 Bytes | 7.1 pulses | CRT |
| 202 | Push-button 9 | Override setpoint | 2 Bytes | 9.2 temperature difference (K) | CRT |