6 sorties fil pilote esclave TXA230B
Hager Electro · Order number TXA230B · Heating, Air Conditioning › Gestionnaire d'énergie
TXA230B
Download .knxprod STXA230B V1.0 1.0 · 68 KB
Product
| Manufacturer | Hager Electro |
|---|---|
| Product name | 6 sorties fil pilote esclave |
| Order number | TXA230B |
| Hardware | 6 sorties fil pilote esclave |
| Medium | Twisted Pair |
| Rail mounted | No |
| Registration | Registered |
| Languages | fr-FR |
| Catalog entry | M-0009_H-9.20.2F.2F.20TXA230B-1_HP-2094-10-09AE_CI-TXA230B-1 |
| Fingerprint | 09AE |
| SHA-256 | ab90321d60c5923c04abd30296798f56c7cc32ff48890a94cab05e3103eb45e7 |
| First seen | 2026-11-25 |
| Markets | 69 markets |
Application program: STXA230B V1.0 1.0
| Application number | $2094 |
|---|---|
| Version | 1.0 |
| Mask version | MV-0701 (7.1) |
| KNX Data Secure | No |
| Parameters | 33 |
| Group objects | 48 |
Group objects (48)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Zone 1 | Sélection de consigne | 1 Byte | CRWU | |
| 1 | Zone 2 | Sélection de consigne | 1 Byte | CRWU | |
| 2 | Zone 3 | Sélection de consigne | 1 Byte | CRWU | |
| 3 | ECS | Réception commande ON / OFF | 1 Bit | CRWU | |
| 4 | ECS | Indication d'état | 1 Bit | CRTU | |
| 5 | Tarif en cours | Réception | 1 Byte | CRWU | |
| 6 | Tarif suivant | Réception | 3 Bytes | CRWU | |
| 7 | Comptage Entrée 1 | Tarif en cours | 1 Byte | CRWU | |
| 8 | Comptage Entrée 1 | Puissance | 4 Bytes | CRTU | |
| 9 | Comptage Entrée 1 | Energie totale | 6 Bytes | CRTU | |
| 10 | Comptage Entrée 1 | Activation mode dynamique | 1 Bit | CRWU | |
| 11 | Activation reset compteur partiel Entrée 1 | Commande | 1 Bit | CRWU | |
| 12 | Comptage Entrée 1 | Energie partielle | 6 Bytes | CRTU | |
| 13 | Comptage Entrée 2 | Tarif en cours | 1 Byte | CRWU | |
| 14 | Comptage Entrée 2 | Puissance | 4 Bytes | CRTU | |
| 15 | Comptage Entrée 2 | Energie totale | 6 Bytes | CRTU | |
| 16 | Comptage Entrée 2 | Activation mode dynamique | 1 Bit | CRWU | |
| 17 | Activation reset compteur partiel Entrée 2 | Commande | 1 Bit | CRWU | |
| 18 | Comptage Entrée 2 | Energie partielle | 6 Bytes | CRTU | |
| 19 | Comptage Entrée 3 | Tarif en cours | 1 Byte | CRWU | |
| 20 | Comptage Entrée 3 | Puissance | 4 Bytes | CRTU | |
| 21 | Comptage Entrée 3 | Energie totale | 6 Bytes | CRTU | |
| 22 | Comptage Entrée 3 | Activation mode dynamique | 1 Bit | CRWU | |
| 23 | Activation reset compteur partiel Entrée 3 | Commande | 1 Bit | CRWU | |
| 24 | Comptage Entrée 3 | Energie partielle | 6 Bytes | CRTU | |
| 25 | Délestage | Indication d'état | 1 Bit | CRWU | |
| 26 | Erreur de branchement | Maintenance | 1 Byte | CRTU | |
| 27 | FP 1 | Délestage | 1 Bit | CRWU | |
| 28 | FP 1 | Consigne en cours | 1 Byte | CRTU | |
| 29 | FP 2 | Délestage | 1 Bit | CRWU | |
| 30 | FP 2 | Consigne en cours | 1 Byte | CRTU | |
| 31 | FP 3 | Délestage | 1 Bit | CRWU | |
| 32 | FP 3 | Consigne en cours | 1 Byte | CRTU | |
| 33 | FP 4 | Délestage | 1 Bit | CRWU | |
| 34 | FP 4 | Consigne en cours | 1 Byte | CRTU | |
| 35 | FP 5 | Délestage | 1 Bit | CRWU | |
| 36 | FP 5 | Consigne en cours | 1 Byte | CRTU | |
| 37 | FP 6 | Délestage | 1 Bit | CRWU | |
| 38 | FP 6 | Consigne en cours | 1 Byte | CRTU | |
| 39 | ECS | Délestage | 1 Bit | CRWU | |
| 40 | LOC_STATE | 1 Bit | CRWU | ||
| 41 | CHANNEL_ACTIVATION | 4 Bytes | CRWU | ||
| 42 | Comptage Entrée 1 | Tension | 2 Bytes | CRTU | |
| 43 | Comptage Entrée 1 | Intensité | 2 Bytes | CRTU | |
| 44 | Comptage Entrée 2 | Tension | 2 Bytes | CRTU | |
| 45 | Comptage Entrée 2 | Intensité | 2 Bytes | CRTU | |
| 46 | Comptage Entrée 3 | Tension | 2 Bytes | CRTU | |
| 47 | Comptage Entrée 3 | Intensité | 2 Bytes | CRTU |
Parameters (11)
| Parameter | Type | Default |
|---|---|---|
| Mode économie - zone 1 | list | Confort -1 °C |
| Mode économie - zone 2 | list | Confort -1 °C |
| Mode économie - zone 3 | list | Confort -1 °C |
| Emission puissance si variation de (W) | signedInt 0…1000000 | 500 |
| Emission puissance (mode dynamique) si variation de (W) | signedInt 0…1000000 | 50 |
| Emission énergie totale si variation de (Wh) | signedInt 0…1000000 | 1000 |
| Emission énergie partielle si variation de (Wh) | signedInt 0…1000000 | 100 |
| Emission puissance toutes les : | list | 5 min |
| Emission énergie toutes les : | list | 5 min |
| Durée du mode dynamique | list | 15 min |
| Version du logiciel d'application | text | 1.0.4 |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| STXA230B V1.0 1.0 latest | $2094 | 09AE | 2026-11-25 | 68 KB | Download |
About this file
This is the official ETS product database for the Hager Electro 6 sorties fil pilote esclave (TXA230B), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from Hager Electro
- 6-output module heating actuator TX206H
- Thermostat TX320
- Valve actuator TX501
- Valve actuator with temperature control TX502
- 6 sorties fil pilote maître TXA230A
- Heating actuator 6 channels KNX, with regulation, 24/230V TXM646R
- Heating actuator 6 channels KNX 24/230V TXM646T
- Heating actuator 1 gang 230V AC flush mounted TYB641A
- Room programmer 6 zones TYD480
- Fan coil actuator 2 gang 10A TYF642F
- Heating actuator 6 gang triac 230V AC TYF646T
- KNX Heating output 6 gang triac 24/230V TYF656T