Heating actuator 6 gang triac 230V AC TYF646T
Hager Electro · Order number TYF646T · Heating, Air Conditioning › Heating actuators
Download .knxprod TL646A V1.1 1.1 · 95 KB
Product
| Manufacturer | Hager Electro |
|---|---|
| Product name | Heating actuator 6 gang triac 230V AC |
| Order number | TYF646T |
| Hardware | Heizungsaktor 6 fach Triac 230V AC REG |
| Medium | Twisted Pair |
| Bus current (mA) | 6 |
| Rail mounted | Yes |
| Width (mm) | 70 |
| Registration | Certified |
| Languages | de-DE, en-US |
| Catalog entry | M-0009_H-9.20.2F.2F.20TYF646T-1-O000A_HP-20A2-11-1255-O000A_CI-TYF646T-1 |
| Fingerprint | 1255 |
| SHA-256 | 70577c3651f6f0fca2c253d79835527b0460f1c1c2eb7baafe99cceb8d0ea6f3 |
| First seen | 2026-11-25 |
| Markets | 69 markets |
Application program: TL646A V1.1 1.1
| Application number | $20A2 |
|---|---|
| Version | 1.1 |
| Mask version | MV-0012 (1.2) |
| KNX Data Secure | No |
| Parameters | 454 |
| Group objects | 82 |
Group objects (82)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Object 1 | 1 Byte | CWT | ||
| 0 | Manipulated variable output 1 | Input | 1 Bit | CW | |
| 0 | Manipulated variable output 1 | Input | 1 Byte | CW | |
| 1 | Object 2 | 1 Byte | CWT | ||
| 1 | Manipulated variable output 2 | Input | 1 Bit | CW | |
| 1 | Manipulated variable output 2 | Input | 1 Byte | CW | |
| 2 | Object 3 | 1 Byte | CWT | ||
| 2 | Manipulated variable output 3 | Input | 1 Bit | CW | |
| 2 | Manipulated variable output 3 | Input | 1 Byte | CW | |
| 3 | Object 4 | 1 Byte | CWT | ||
| 3 | Manipulated variable output 4 | Input | 1 Bit | CW | |
| 3 | Manipulated variable output 4 | Input | 1 Byte | CW | |
| 4 | Object 5 | 1 Byte | CWT | ||
| 4 | Manipulated variable output 5 | Input | 1 Bit | CW | |
| 4 | Manipulated variable output 5 | Input | 1 Byte | CW | |
| 5 | Object 6 | 1 Byte | CWT | ||
| 5 | Manipulated variable output 6 | Input | 1 Bit | CW | |
| 5 | Manipulated variable output 6 | Input | 1 Byte | CW | |
| 6 | Object 7 | 1 Byte | CWT | ||
| 6 | Manipulated variable output 1 | Status | 1 Byte | CR | |
| 6 | Manipulated variable output 1 | Status | 1 Bit | CR | |
| 6 | Manipulated variable output 1 | Status | 1 Byte | CT | |
| 6 | Manipulated variable output 1 | Status | 1 Bit | CT | |
| 7 | Object 8 | 1 Bit | CWT | ||
| 7 | Manipulated variable output 2 | Status | 1 Bit | CR | |
| 7 | Manipulated variable output 2 | Status | 1 Byte | CR | |
| 7 | Manipulated variable output 2 | Status | 1 Bit | CT | |
| 7 | Manipulated variable output 2 | Status | 1 Byte | CT | |
| 8 | Object 9 | 1 Bit | CWT | ||
| 8 | Manipulated variable output 3 | Status | 1 Bit | CR | |
| 8 | Manipulated variable output 3 | Status | 1 Byte | CR | |
| 8 | Manipulated variable output 3 | Status | 1 Bit | CT | |
| 8 | Manipulated variable output 3 | Status | 1 Byte | CT | |
| 9 | Object 10 | 1 Bit | CWT | ||
| 9 | Manipulated variable output 4 | Status | 1 Bit | CR | |
| 9 | Manipulated variable output 4 | Status | 1 Byte | CR | |
| 9 | Manipulated variable output 4 | Status | 1 Bit | CT | |
| 9 | Manipulated variable output 4 | Status | 1 Byte | CT | |
| 10 | Object 11 | 1 Bit | CWT | ||
| 10 | Manipulated variable output 5 | Status | 1 Bit | CR | |
| 10 | Manipulated variable output 5 | Status | 1 Byte | CR | |
| 10 | Manipulated variable output 5 | Status | 1 Bit | CT | |
| 10 | Manipulated variable output 5 | Status | 1 Byte | CT | |
| 11 | Object 12 | 1 Bit | CWT | ||
| 11 | Manipulated variable output 6 | Status | 1 Bit | CR | |
| 11 | Manipulated variable output 6 | Status | 1 Byte | CR | |
| 11 | Manipulated variable output 6 | Status | 1 Bit | CT | |
| 11 | Manipulated variable output 6 | Status | 1 Byte | CT | |
| 12 | Object 13 | 1 Bit | CWT | ||
| 12 | Forced position output 1 | Input | 1 Bit | CW | |
| 13 | Object 14 | 1 Bit | CWT | ||
| 13 | Forced position output 2 | Input | 1 Bit | CW | |
| 14 | Object 15 | 1 Bit | CWT | ||
| 14 | Forced position output 3 | Input | 1 Bit | CW | |
| 15 | Object 16 | 1 Bit | CWT | ||
| 15 | Forced position output 4 | Input | 1 Bit | CW | |
| 16 | Object 17 | 1 Bit | CWT | ||
| 16 | Forced position output 5 | Input | 1 Bit | CW | |
| 17 | Object 18 | 1 Bit | CWT | ||
| 17 | Forced position output 6 | Input | 1 Bit | CW | |
| 18 | Object 19 | 1 Bit | CWT | ||
| 18 | Output 1 | Overload / short circuit | 1 Bit | CT | |
| 19 | Object 20 | 1 Bit | CWT | ||
| 19 | Output 2 | Overload / short circuit | 1 Bit | CT | |
| 20 | Object 21 | 1 Bit | CWT | ||
| 20 | Output 3 | Overload / short circuit | 1 Bit | CT | |
| 21 | Object 22 | 1 Bit | CWT | ||
| 21 | Output 4 | Overload / short circuit | 1 Bit | CT | |
| 22 | Object 23 | 1 Bit | CWT | ||
| 22 | Output 5 | Overload / short circuit | 1 Bit | CT | |
| 23 | Object 24 | 1 Bit | CWT | ||
| 23 | Output 6 | Overload / short circuit | 1 Bit | CT | |
| 24 | Object 25 | 1 Bit | CWT | ||
| 24 | Power failure | Alarm message | 1 Bit | CT | |
| 25 | Object 26 | 1 Bit | CWT | ||
| 25 | All valves are closed | Status valves | 1 Bit | CT | |
| 26 | Object 27 | 1 Bit | CWT | ||
| 26 | Cyclical monitoring of manipulated variables | Alarm message | 1 Bit | CT | |
| 27 | Object 28 | 1 Bit | CWT | ||
| 27 | Summer / winter | Switch over | 1 Bit | CW | |
| 28 | Object 29 | 1 Byte | CWT | ||
| 28 | Largest manipulated variable of all outputs | Max. value | 1 Byte | CT |
Parameters (80)
| Parameter | Type | Default |
|---|---|---|
| Objekte | list | Object value at power failure = 0 |
| Init_Kurzschlussmeldung | unsignedInt 0…255 | 0 |
| Valve protection | list | YES |
| Status object: All valves are closed? | list | disabled |
| Polarity of object: All valves are closed | list | Object value if all valves are closed = 0 |
| Transmit status of manipulated variable | list | No status |
| Status_Ventilstellungen | list | At modification |
| Summer/winter mode switch over ? | list | NO |
| Polarity of object: Summer/winter switch over | list | Summer = 0 / winter = 1 |
| Operating mode after commisioning | list | Winter mode |
| Feedback of the largest manip. variable? (only 1 Byte values) | list | NO |
| Cycle time of the PWM periode (only 1 Byte values) | list | 15 min (e.g. floor heating, several heatings) |
| Telegrammratenbegrenzung (Anzahl der Telegramme in 17 s) | unsignedInt 0…127 | 30 |
| Monitoring of manipulated variable? | list | disabled |
| Monitoring time at cyclical monitoring of manipulated variable | list | 11 min |
| Polarity of object: Cycl. monitoring of manip. variable | list | Object value at lack of man. variable = 1 |
| Alarm message at power failure? | list | NO |
| Polarity of object: Power failure | list | Object value at power failure = 1 |
| Manipulated variable at summer emergency mode | list | 50% |
| Manipulated variable at emergency mode | list | 50% |
| Manipulated variable at winter emergency mode | list | 50% |
| Output 1: | list | Only at bus voltage failure |
| Output 1: | list | Only at bus voltage restore |
| Output 1: | list | NO |
| Output 1: | list | Only at lack of cycl. manipulated variable |
| Output 1: | list | Bus voltage restore + lack of cycl. man. variable |
| Output 1: | list | Bus voltage failure + lack of cycl. man. variable |
| Output 1: | list | Bus volt. fail./restore + lack of cycl. man. var. |
| Output 1: | list | At bus voltage failure + restore |
| Output 2: | list | At bus voltage failure + restore |
| Output 2: | list | NO |
| Output 2: | list | Only at bus voltage restore |
| Output 2: | list | Only at bus voltage failure |
| Output 2: | list | Only at lack of cycl. manipulated variable |
| Output 2: | list | Bus voltage restore + lack of cycl. man. variable |
| Output 2: | list | Bus voltage failure + lack of cycl. man. variable |
| Output 2: | list | Bus volt. fail./restore + lack of cycl. man. var. |
| Output 3: | list | NO |
| Output 3: | list | Only at bus voltage restore |
| Output 3: | list | Only at bus voltage failure |
| Output 3: | list | At bus voltage failure + restore |
| Output 3: | list | Only at lack of cycl. manipulated variable |
| Output 3: | list | Bus voltage restore + lack of cycl. man. variable |
| Output 3: | list | Bus volt. fail./restore + lack of cycl. man. var. |
| Output 3: | list | Bus voltage failure + lack of cycl. man. variable |
| Output 4: | list | NO |
| Output 4: | list | Only at bus voltage restore |
| Output 4: | list | Only at bus voltage failure |
| Output 4: | list | At bus voltage failure + restore |
| Output 4: | list | Only at lack of cycl. manipulated variable |
| Output 4: | list | Bus voltage restore + lack of cycl. man. variable |
| Output 4: | list | Bus volt. fail./restore + lack of cycl. man. var. |
| Output 4: | list | Bus voltage failure + lack of cycl. man. variable |
| Output 5: | list | Bus voltage restore + lack of cycl. man. variable |
| Output 5: | list | Only at lack of cycl. manipulated variable |
| Output 5: | list | Bus volt. fail./restore + lack of cycl. man. var. |
| Output 5: | list | Bus voltage failure + lack of cycl. man. variable |
| Output 5: | list | NO |
| Output 5: | list | Only at bus voltage restore |
| Output 5: | list | Only at bus voltage failure |
| Output 5: | list | At bus voltage failure + restore |
| Output 6: | list | Bus voltage restore + lack of cycl. man. variable |
| Output 6: | list | Only at lack of cycl. manipulated variable |
| Output 6: | list | Bus volt. fail./restore + lack of cycl. man. var. |
| Output 6: | list | Bus voltage failure + lack of cycl. man. variable |
| Output 6: | list | NO |
| Output 6: | list | Only at bus voltage restore |
| Output 6: | list | Only at bus voltage failure |
| Output 6: | list | At bus voltage failure + restore |
| Mode of operation of valve/valve drive combination | list | Current-free closed |
| Type of manipulated variable | list | Switching (1 Bit) |
| Cycl. monitoring of manipulated variable | list | disabled |
| Forced position? | list | disabled |
| Manipulated variable at summer forced position | list | 40% |
| Manipulated variable at forced position | list | 40% |
| Manipulated variable at winter forced position | list | 40% |
| Behaviour after bus voltage failure | list | Man. variable of emergency mode |
| Behaviour after bus voltage return | list | Valve closes |
| Object: Overload / short circuit? | list | disabled |
| Polarity of object: Overload/short circuit | list | Object value at overload / short circuit = 0 |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| TL646A V1.1 1.1 latest | $20A2 | 1255 | 2026-11-25 | 95 KB | Download |
About this file
This is the official ETS product database for the Hager Electro Heating actuator 6 gang triac 230V AC (TYF646T), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from Hager Electro
- 6-output module heating actuator TX206H
- Thermostat TX320
- Valve actuator TX501
- Valve actuator with temperature control TX502
- 6 sorties fil pilote maître TXA230A
- 6 sorties fil pilote esclave TXA230B
- Heating actuator 6 channels KNX, with regulation, 24/230V TXM646R
- Heating actuator 6 channels KNX 24/230V TXM646T
- Heating actuator 1 gang 230V AC flush mounted TYB641A
- Room programmer 6 zones TYD480
- Fan coil actuator 2 gang 10A TYF642F
- KNX Heating output 6 gang triac 24/230V TYF656T