Heating actuator 6 channels KNX, with regulation, 24/230V TXM646R

Hager Electro · Order number TXM646R · Heating, Air Conditioning › Thermostat

Download .knxprod STXM646R 1.2 · 798 KB

Product

ManufacturerHager Electro
Product nameHeating actuator 6 channels KNX, with regulation, 24/230V
Order numberTXM646R
HardwareTXM646R
MediumTwisted Pair
Bus current (mA)19
Rail mountedYes
RegistrationRegistered · 2019-10-23
Languagesfr-FR, de-DE, es-ES, it-IT, nl-NL, pt-PT, nb-NO, sv-SE
Catalog entryM-0009_H-9.20.2F.2F.20TXM646R-18_HP-E0D3-12-35BF_CI-TXM646R-1
Fingerprint35BF
SHA-256fac62630ffee54571c83c311b3c7cd49386ad106ad6154b5f7eb13d155880920
First seen2026-11-25
Markets69 markets

Application program: STXM646R 1.2

Application number$E0D3
Version1.2
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version5.0
Parameters5259
Group objects1369
Group objects (1369)
NoNameFunctionSizeDPTFlags
1{{0}}ON/OFF1 Bit1.1 switchCWTU
2{{0}}Valve position in %1 Byte5.1 percentage (0..100%)CWTU
3{{0}}Status indication ON/OFF1 Bit1.1 switchCRT
4{{0}}Status valve position in %1 Byte5.1 percentage (0..100%)CRT
5{{0}}Command value monitoring failure1 Bit1.5 alarmCRT
6{{0}}Short circuit/Overload status indication1 Bit1.5 alarmCRT
7{{0}}Priority2 Bit2.2 boolean controlCWTU
8{{0}}Priority (1 bit)1 Bit1.3 enableCWTU
9{{0}}Status indication priority1 Bit1.3 enableCRT
10{{0}}Heating/Cooling - changeover1 Bit1.100 cooling/heatingCWTU
11{{0}}Command value limitation activation1 Bit1.3 enableCWTU
12{{0}}Hours counter value (h)2 Bytes7.7 time (h)CRT
13{{0}}Hours counter value (s)4 Bytes13.100 time lag (s)CRT
14{{0}}Reset hours counter value1 Bit1.15 resetCWTU
15{{0}}Hours counter setpoint reached1 Bit1.11 stateCRT
16{{0}}Hours counter setpoint (h)2 Bytes7.7 time (h)CWTU
17{{0}}Hours counter setpoint (s)4 Bytes13.100 time lag (s)CWTU
18{{0}}Valve protection date3 Bytes11.1 dateCWTU
19{{0}}Valve protection time3 Bytes10.1 time of dayCWTU
20{{0}}Valve protection date and time8 Bytes19.1 date timeCWTU
21{{0}}Valve protection duration2 Bytes7.6 time (min)CWTU
22{{0}}Valve protection periodicity2 Bytes7.7 time (h)CWTU
23{{0}}Valve protection start/stop1 Bit1.10 start/stopCWTU
24{{0}}Lock-up 11 Bit1.3 enableCWTU
25{{0}}Lock-up 21 Bit1.3 enableCWTU
26{{0}}Status indication lock-up1 Bit1.3 enableCRT
27{{0}}Room temperature failure1 Bit1.5 alarmCWTU
28{{0}}ON/OFF1 Bit1.1 switchCWTU
29{{0}}Valve position in %1 Byte5.1 percentage (0..100%)CWTU
30{{0}}Status indication ON/OFF1 Bit1.1 switchCRT
31{{0}}Status valve position in %1 Byte5.1 percentage (0..100%)CRT
32{{0}}Command value monitoring failure1 Bit1.5 alarmCRT
33{{0}}Short circuit/Overload status indication1 Bit1.5 alarmCRT
34{{0}}Priority2 Bit2.2 boolean controlCWTU
35{{0}}Priority (1 bit)1 Bit1.3 enableCWTU
36{{0}}Status indication priority1 Bit1.3 enableCRT
37{{0}}Heating/Cooling - changeover1 Bit1.100 cooling/heatingCWTU
38{{0}}Command value limitation activation1 Bit1.3 enableCWTU
39{{0}}Hours counter value (h)2 Bytes7.7 time (h)CRT
40{{0}}Hours counter value (s)4 Bytes13.100 time lag (s)CRT
41{{0}}Reset hours counter value1 Bit1.15 resetCWTU
42{{0}}Hours counter setpoint reached1 Bit1.11 stateCRT
43{{0}}Hours counter setpoint (h)2 Bytes7.7 time (h)CWTU
44{{0}}Hours counter setpoint (s)4 Bytes13.100 time lag (s)CWTU
45{{0}}Valve protection date3 Bytes11.1 dateCWTU
46{{0}}Valve protection time3 Bytes10.1 time of dayCWTU
47{{0}}Valve protection date and time8 Bytes19.1 date timeCWTU
48{{0}}Valve protection duration2 Bytes7.6 time (min)CWTU
49{{0}}Valve protection periodicity2 Bytes7.7 time (h)CWTU
50{{0}}Valve protection start/stop1 Bit1.10 start/stopCWTU
51{{0}}Lock-up 11 Bit1.3 enableCWTU
52{{0}}Lock-up 21 Bit1.3 enableCWTU
53{{0}}Status indication lock-up1 Bit1.3 enableCRT
54{{0}}Room temperature failure1 Bit1.5 alarmCWTU
55{{0}}ON/OFF1 Bit1.1 switchCWTU
56{{0}}Valve position in %1 Byte5.1 percentage (0..100%)CWTU
57{{0}}Status indication ON/OFF1 Bit1.1 switchCRT
58{{0}}Status valve position in %1 Byte5.1 percentage (0..100%)CRT
59{{0}}Command value monitoring failure1 Bit1.5 alarmCRT
60{{0}}Short circuit/Overload status indication1 Bit1.5 alarmCRT
61{{0}}Priority2 Bit2.2 boolean controlCWTU
62{{0}}Priority (1 bit)1 Bit1.3 enableCWTU
63{{0}}Status indication priority1 Bit1.3 enableCRT
64{{0}}Heating/Cooling - changeover1 Bit1.100 cooling/heatingCWTU
65{{0}}Command value limitation activation1 Bit1.3 enableCWTU
66{{0}}Hours counter value (h)2 Bytes7.7 time (h)CRT
67{{0}}Hours counter value (s)4 Bytes13.100 time lag (s)CRT
68{{0}}Reset hours counter value1 Bit1.15 resetCWTU
69{{0}}Hours counter setpoint reached1 Bit1.11 stateCRT
70{{0}}Hours counter setpoint (h)2 Bytes7.7 time (h)CWTU
71{{0}}Hours counter setpoint (s)4 Bytes13.100 time lag (s)CWTU
72{{0}}Valve protection date3 Bytes11.1 dateCWTU
73{{0}}Valve protection time3 Bytes10.1 time of dayCWTU
74{{0}}Valve protection date and time8 Bytes19.1 date timeCWTU
75{{0}}Valve protection duration2 Bytes7.6 time (min)CWTU
76{{0}}Valve protection periodicity2 Bytes7.7 time (h)CWTU
77{{0}}Valve protection start/stop1 Bit1.10 start/stopCWTU
78{{0}}Lock-up 11 Bit1.3 enableCWTU
79{{0}}Lock-up 21 Bit1.3 enableCWTU
80{{0}}Status indication lock-up1 Bit1.3 enableCRT
81{{0}}Room temperature failure1 Bit1.5 alarmCWTU
82{{0}}ON/OFF1 Bit1.1 switchCWTU
83{{0}}Valve position in %1 Byte5.1 percentage (0..100%)CWTU
84{{0}}Status indication ON/OFF1 Bit1.1 switchCRT
85{{0}}Status valve position in %1 Byte5.1 percentage (0..100%)CRT
86{{0}}Command value monitoring failure1 Bit1.5 alarmCRT
87{{0}}Short circuit/Overload status indication1 Bit1.5 alarmCRT
88{{0}}Priority2 Bit2.2 boolean controlCWTU
89{{0}}Priority (1 bit)1 Bit1.3 enableCWTU
90{{0}}Status indication priority1 Bit1.3 enableCRT
91{{0}}Heating/Cooling - changeover1 Bit1.100 cooling/heatingCWTU
92{{0}}Command value limitation activation1 Bit1.3 enableCWTU
93{{0}}Hours counter value (h)2 Bytes7.7 time (h)CRT
94{{0}}Hours counter value (s)4 Bytes13.100 time lag (s)CRT
95{{0}}Reset hours counter value1 Bit1.15 resetCWTU
96{{0}}Hours counter setpoint reached1 Bit1.11 stateCRT
97{{0}}Hours counter setpoint (h)2 Bytes7.7 time (h)CWTU
98{{0}}Hours counter setpoint (s)4 Bytes13.100 time lag (s)CWTU
99{{0}}Valve protection date3 Bytes11.1 dateCWTU
100{{0}}Valve protection time3 Bytes10.1 time of dayCWTU
101{{0}}Valve protection date and time8 Bytes19.1 date timeCWTU
102{{0}}Valve protection duration2 Bytes7.6 time (min)CWTU
103{{0}}Valve protection periodicity2 Bytes7.7 time (h)CWTU
104{{0}}Valve protection start/stop1 Bit1.10 start/stopCWTU
105{{0}}Lock-up 11 Bit1.3 enableCWTU
106{{0}}Lock-up 21 Bit1.3 enableCWTU
107{{0}}Status indication lock-up1 Bit1.3 enableCRT
108{{0}}Room temperature failure1 Bit1.5 alarmCWTU
109{{0}}ON/OFF1 Bit1.1 switchCWTU
110{{0}}Valve position in %1 Byte5.1 percentage (0..100%)CWTU
111{{0}}Status indication ON/OFF1 Bit1.1 switchCRT
112{{0}}Status valve position in %1 Byte5.1 percentage (0..100%)CRT
113{{0}}Command value monitoring failure1 Bit1.5 alarmCRT
114{{0}}Short circuit/Overload status indication1 Bit1.5 alarmCRT
115{{0}}Priority2 Bit2.2 boolean controlCWTU
116{{0}}Priority (1 bit)1 Bit1.3 enableCWTU
117{{0}}Status indication priority1 Bit1.3 enableCRT
118{{0}}Heating/Cooling - changeover1 Bit1.100 cooling/heatingCWTU
119{{0}}Command value limitation activation1 Bit1.3 enableCWTU
120{{0}}Hours counter value (h)2 Bytes7.7 time (h)CRT
121{{0}}Hours counter value (s)4 Bytes13.100 time lag (s)CRT
122{{0}}Reset hours counter value1 Bit1.15 resetCWTU
123{{0}}Hours counter setpoint reached1 Bit1.11 stateCRT
124{{0}}Hours counter setpoint (h)2 Bytes7.7 time (h)CWTU
125{{0}}Hours counter setpoint (s)4 Bytes13.100 time lag (s)CWTU
126{{0}}Valve protection date3 Bytes11.1 dateCWTU
127{{0}}Valve protection time3 Bytes10.1 time of dayCWTU
128{{0}}Valve protection date and time8 Bytes19.1 date timeCWTU
129{{0}}Valve protection duration2 Bytes7.6 time (min)CWTU
130{{0}}Valve protection periodicity2 Bytes7.7 time (h)CWTU
131{{0}}Valve protection start/stop1 Bit1.10 start/stopCWTU
132{{0}}Lock-up 11 Bit1.3 enableCWTU
133{{0}}Lock-up 21 Bit1.3 enableCWTU
134{{0}}Status indication lock-up1 Bit1.3 enableCRT
135{{0}}Room temperature failure1 Bit1.5 alarmCWTU
136{{0}}ON/OFF1 Bit1.1 switchCWTU
137{{0}}Valve position in %1 Byte5.1 percentage (0..100%)CWTU
138{{0}}Status indication ON/OFF1 Bit1.1 switchCRT
139{{0}}Status valve position in %1 Byte5.1 percentage (0..100%)CRT
140{{0}}Command value monitoring failure1 Bit1.5 alarmCRT
141{{0}}Short circuit/Overload status indication1 Bit1.5 alarmCRT
142{{0}}Priority2 Bit2.2 boolean controlCWTU
143{{0}}Priority (1 bit)1 Bit1.3 enableCWTU
144{{0}}Status indication priority1 Bit1.3 enableCRT
145{{0}}Heating/Cooling - changeover1 Bit1.100 cooling/heatingCWTU
146{{0}}Command value limitation activation1 Bit1.3 enableCWTU
147{{0}}Hours counter value (h)2 Bytes7.7 time (h)CRT
148{{0}}Hours counter value (s)4 Bytes13.100 time lag (s)CRT
149{{0}}Reset hours counter value1 Bit1.15 resetCWTU
150{{0}}Hours counter setpoint reached1 Bit1.11 stateCRT
151{{0}}Hours counter setpoint (h)2 Bytes7.7 time (h)CWTU
152{{0}}Hours counter setpoint (s)4 Bytes13.100 time lag (s)CWTU
153{{0}}Valve protection date3 Bytes11.1 dateCWTU
154{{0}}Valve protection time3 Bytes10.1 time of dayCWTU
155{{0}}Valve protection date and time8 Bytes19.1 date timeCWTU
156{{0}}Valve protection duration2 Bytes7.6 time (min)CWTU
157{{0}}Valve protection periodicity2 Bytes7.7 time (h)CWTU
158{{0}}Valve protection start/stop1 Bit1.10 start/stopCWTU
159{{0}}Lock-up 11 Bit1.3 enableCWTU
160{{0}}Lock-up 21 Bit1.3 enableCWTU
161{{0}}Status indication lock-up1 Bit1.3 enableCRT
162{{0}}Room temperature failure1 Bit1.5 alarmCWTU
163GeneralHeating activation1 Bit1.1 switchCWTU
164GeneralHeat requirement1 Bit1.2 booleanCRT
165{{0}}Setpoint selection1 Byte20.102 HVAC modeCWTU
166{{0}}Comfort1 Bit1.1 switchCWTU
167{{0}}Standby mode1 Bit1.1 switchCWTU
168{{0}}Night setpoint1 Bit1.1 switchCWTU
169{{0}}Frost/heat protection1 Bit1.1 switchCWTU
170{{0}}Setpoint selection automatic control1 Byte20.102 HVAC modeCWTU
171{{0}}Automatic control deactivation1 Bit1.3 enableCWTU
172{{0}}Heating/Cooling - changeover1 Bit1.100 cooling/heatingCWTU
173{{0}}Priority2 Bit2.2 boolean controlCWTU
174{{0}}Status indication priority1 Bit1.11 stateCWTU
175{{0}}Priority1 Byte20.102 HVAC modeCWTU
176{{0}}Windows contact1 Bit1.19 window/doorCWTU
177{{0}}Scene1 Byte18.1 scene controlCWTU
178{{0}}Status indication setpoint selection1 Byte20.102 HVAC modeCRT
179{{0}}Automatic control deactivation status1 Bit1.3 enableCRT
180{{0}}Heating/Cooling - status indication1 Bit1.100 cooling/heatingCRT
181{{0}}Status indication heating active1 Bit1.11 stateCRT
182{{0}}Status indication cooling active1 Bit1.11 stateCRT
183{{0}}Status indication priority1 Bit1.11 stateCRT
184{{0}}ON/OFF1 Bit1.1 switchCRT
185{{0}}Valve position in %1 Byte5.1 percentage (0..100%)CRT
186{{0}}ON/OFF - basic cooling1 Bit1.1 switchCRT
187{{0}}Valve position in % - basic cooling1 Byte5.1 percentage (0..100%)CRT
188{{0}}ON/OFF - additional heating1 Bit1.1 switchCRT
189{{0}}Valve position in % - additional heating1 Byte5.1 percentage (0..100%)CRT
190{{0}}ON/OFF - additional cooling1 Bit1.1 switchCRT
191{{0}}Valve position in % - additional cooling1 Byte5.1 percentage (0..100%)CRT
192{{0}}Room temperature 12 Bytes9.1 temperature (°C)CWTU
193{{0}}Room temperature 22 Bytes9.1 temperature (°C)CWTU
194{{0}}Room temperature 32 Bytes9.1 temperature (°C)CWTU
195{{0}}Floor temperature2 Bytes9.1 temperature (°C)CWTU
196{{0}}Status indication room temperature2 Bytes9.1 temperature (°C)CRT
197{{0}}Room temperature failure1 Bit1.5 alarmCRT
198{{0}}Minimum room temperature1 Bit1.5 alarmCRT
199{{0}}Maximum room temperature1 Bit1.5 alarmCRT
200{{0}}Ventilation automatic/manual mode1 Bit1.1 switchCWTU
201{{0}}Status ventilation step 1-61 Byte5.10 counter pulses (0..255)CWTU
202{{0}}Status ventilation step 11 Bit1.1 switchCWTU
203{{0}}Status ventilation step 21 Bit1.1 switchCWTU
204{{0}}Status ventilation step 31 Bit1.1 switchCWTU
205{{0}}Status ventilation step 41 Bit1.1 switchCWTU
206{{0}}Status ventilation step 51 Bit1.1 switchCWTU
207{{0}}Status ventilation step 61 Bit1.1 switchCWTU
208{{0}}Ventilation step 1-61 Byte5.10 counter pulses (0..255)CRT
209{{0}}Ventilation step 11 Bit1.1 switchCRT
210{{0}}Ventilation step 21 Bit1.1 switchCRT
211{{0}}Ventilation step 31 Bit1.1 switchCRT
212{{0}}Ventilation step 41 Bit1.1 switchCRT
213{{0}}Ventilation step 51 Bit1.1 switchCRT
214{{0}}Ventilation step 61 Bit1.1 switchCRT
215{{0}}Comfort setpoint heating2 Bytes9.1 temperature (°C)CWTU
215{{0}}Reference setpoint2 Bytes9.1 temperature (°C)CWTU
216{{0}}Standby setpoint heating2 Bytes9.1 temperature (°C)CWTU
217{{0}}Night setpoint heating2 Bytes9.1 temperature (°C)CWTU
218{{0}}Frost protection setpoint heating2 Bytes9.1 temperature (°C)CWTU
219{{0}}Setpoints heating8 BytesCWTU
220{{0}}Comfort setpoint cooling2 Bytes9.1 temperature (°C)CWTU
221{{0}}Standby setpoint cooling2 Bytes9.1 temperature (°C)CWTU
222{{0}}Night setpoint cooling2 Bytes9.1 temperature (°C)CWTU
223{{0}}Heat protection setpoint cooling2 Bytes9.1 temperature (°C)CWTU
224{{0}}Setpoints cooling8 BytesCWTU
225{{0}}Setpoint shift2 Bytes9.2 temperature difference (K)CWTU
226{{0}}Current setpoint2 Bytes9.1 temperature (°C)CWTU
227{{0}}Status indication setpoint shift2 Bytes9.2 temperature difference (K)CRT
228{{0}}Status indication reference setpoint2 Bytes9.1 temperature (°C)CRT
229{{0}}Status indication comfort setpoint heating2 Bytes9.1 temperature (°C)CRT
230{{0}}Status indication standby setpoint heating2 Bytes9.1 temperature (°C)CRT
231{{0}}Status indication night setpoint heating2 Bytes9.1 temperature (°C)CRT
232{{0}}Status indication frost protection setpoint heating2 Bytes9.1 temperature (°C)CRT
233{{0}}Status indication setpoints heating8 BytesCRT
234{{0}}Status indication comfort setpoint cooling2 Bytes9.1 temperature (°C)CRT
235{{0}}Status indication standby setpoint cooling2 Bytes9.1 temperature (°C)CRT
236{{0}}Status indication night setpoint cooling2 Bytes9.1 temperature (°C)CRT
237{{0}}Status indication heat protection setpoint cooling2 Bytes9.1 temperature (°C)CRT
238{{0}}Status indication setpoints cooling8 BytesCRT
239{{0}}Status current setpoint2 Bytes9.1 temperature (°C)CRT
240{{0}}Presence1 Bit1.1 switchCWTU
241{{0}}Lock-up additional step1 Bit1.1 switchCWTU
242{{0}}Heating deactivation1 Bit1.3 enableCWTU
243{{0}}Cooling deactivation1 Bit1.3 enableCWTU
244{{0}}Heating deactivation status1 Bit1.3 enableCRT
245{{0}}Cooling deactivation status1 Bit1.3 enableCRT
246{{0}}Thermostat deactivation1 Bit1.3 enableCWTU
247{{0}}Status indication thermostat deactivation1 Bit1.3 enableCRT
248{{0}}Timer1 Bit1.10 start/stopCWTU
249{{0}}Timer duration3 Bytes10.1 time of dayCWTU
250{{0}}Timer1 Byte20.102 HVAC modeCWTU
251{{0}}Preset 11 Bit1.3 enableCWTU
252{{0}}Preset 21 Bit1.3 enableCWTU
253{{0}}Preset 1 authorization1 Bit1.3 enableCWTU
254{{0}}Preset 2 authorization1 Bit1.3 enableCWTU
255{{0}}Lock-up 11 Bit1.3 enableCWTU
256{{0}}Lock-up 21 Bit1.3 enableCWTU
257{{0}}Status indication lock-up1 Bit1.3 enableCRT
258{{0}}Valve protection date3 Bytes11.1 dateCWTU
259{{0}}Valve protection time3 Bytes10.1 time of dayCWTU
260{{0}}Valve protection date and time8 Bytes19.1 date timeCWTU
261{{0}}Valve protection duration2 Bytes7.6 time (min)CWTU
262{{0}}Valve protection periodicity2 Bytes7.7 time (h)CWTU
263{{0}}Valve protection start/stop1 Bit1.10 start/stopCWTU
264{{0}}Setpoint selection1 Byte20.102 HVAC modeCWTU
265{{0}}Comfort1 Bit1.1 switchCWTU
266{{0}}Standby mode1 Bit1.1 switchCWTU
267{{0}}Night setpoint1 Bit1.1 switchCWTU
268{{0}}Frost/heat protection1 Bit1.1 switchCWTU
269{{0}}Setpoint selection automatic control1 Byte20.102 HVAC modeCWTU
270{{0}}Automatic control deactivation1 Bit1.3 enableCWTU
271{{0}}Heating/Cooling - changeover1 Bit1.100 cooling/heatingCWTU
272{{0}}Priority2 Bit2.2 boolean controlCWTU
273{{0}}Status indication priority1 Bit1.11 stateCWTU
274{{0}}Priority1 Byte20.102 HVAC modeCWTU
275{{0}}Windows contact1 Bit1.19 window/doorCWTU
276{{0}}Scene1 Byte18.1 scene controlCWTU
277{{0}}Status indication setpoint selection1 Byte20.102 HVAC modeCRT
278{{0}}Automatic control deactivation status1 Bit1.3 enableCRT
279{{0}}Heating/Cooling - status indication1 Bit1.100 cooling/heatingCRT
280{{0}}Status indication heating active1 Bit1.11 stateCRT
281{{0}}Status indication cooling active1 Bit1.11 stateCRT
282{{0}}Status indication priority1 Bit1.11 stateCRT
283{{0}}ON/OFF1 Bit1.1 switchCRT
284{{0}}Valve position in %1 Byte5.1 percentage (0..100%)CRT
285{{0}}ON/OFF - basic cooling1 Bit1.1 switchCRT
286{{0}}Valve position in % - basic cooling1 Byte5.1 percentage (0..100%)CRT
287{{0}}ON/OFF - additional heating1 Bit1.1 switchCRT
288{{0}}Valve position in % - additional heating1 Byte5.1 percentage (0..100%)CRT
289{{0}}ON/OFF - additional cooling1 Bit1.1 switchCRT
290{{0}}Valve position in % - additional cooling1 Byte5.1 percentage (0..100%)CRT
291{{0}}Room temperature 12 Bytes9.1 temperature (°C)CWTU
292{{0}}Room temperature 22 Bytes9.1 temperature (°C)CWTU
293{{0}}Room temperature 32 Bytes9.1 temperature (°C)CWTU
294{{0}}Floor temperature2 Bytes9.1 temperature (°C)CWTU
295{{0}}Status indication room temperature2 Bytes9.1 temperature (°C)CRT
296{{0}}Room temperature failure1 Bit1.5 alarmCRT
297{{0}}Minimum room temperature1 Bit1.5 alarmCRT
298{{0}}Maximum room temperature1 Bit1.5 alarmCRT
299{{0}}Ventilation automatic/manual mode1 Bit1.1 switchCWTU
300{{0}}Status ventilation step 1-61 Byte5.10 counter pulses (0..255)CWTU
301{{0}}Status ventilation step 11 Bit1.1 switchCWTU
302{{0}}Status ventilation step 21 Bit1.1 switchCWTU
303{{0}}Status ventilation step 31 Bit1.1 switchCWTU
304{{0}}Status ventilation step 41 Bit1.1 switchCWTU
305{{0}}Status ventilation step 51 Bit1.1 switchCWTU
306{{0}}Status ventilation step 61 Bit1.1 switchCWTU
307{{0}}Ventilation step 1-61 Byte5.10 counter pulses (0..255)CRT
308{{0}}Ventilation step 11 Bit1.1 switchCRT
309{{0}}Ventilation step 21 Bit1.1 switchCRT
310{{0}}Ventilation step 31 Bit1.1 switchCRT
311{{0}}Ventilation step 41 Bit1.1 switchCRT
312{{0}}Ventilation step 51 Bit1.1 switchCRT
313{{0}}Ventilation step 61 Bit1.1 switchCRT
314{{0}}Comfort setpoint heating2 Bytes9.1 temperature (°C)CWTU
314{{0}}Reference setpoint2 Bytes9.1 temperature (°C)CWTU
315{{0}}Standby setpoint heating2 Bytes9.1 temperature (°C)CWTU
316{{0}}Night setpoint heating2 Bytes9.1 temperature (°C)CWTU
317{{0}}Frost protection setpoint heating2 Bytes9.1 temperature (°C)CWTU
318{{0}}Setpoints heating8 BytesCWTU
319{{0}}Comfort setpoint cooling2 Bytes9.1 temperature (°C)CWTU
320{{0}}Standby setpoint cooling2 Bytes9.1 temperature (°C)CWTU
321{{0}}Night setpoint cooling2 Bytes9.1 temperature (°C)CWTU
322{{0}}Heat protection setpoint cooling2 Bytes9.1 temperature (°C)CWTU
323{{0}}Setpoints cooling8 BytesCWTU
324{{0}}Setpoint shift2 Bytes9.2 temperature difference (K)CWTU
325{{0}}Current setpoint2 Bytes9.1 temperature (°C)CWTU
326{{0}}Status indication setpoint shift2 Bytes9.2 temperature difference (K)CRT
327{{0}}Status indication reference setpoint2 Bytes9.1 temperature (°C)CRT
328{{0}}Status indication comfort setpoint heating2 Bytes9.1 temperature (°C)CRT
329{{0}}Status indication standby setpoint heating2 Bytes9.1 temperature (°C)CRT
330{{0}}Status indication night setpoint heating2 Bytes9.1 temperature (°C)CRT
331{{0}}Status indication frost protection setpoint heating2 Bytes9.1 temperature (°C)CRT
332{{0}}Status indication setpoints heating8 BytesCRT
333{{0}}Status indication comfort setpoint cooling2 Bytes9.1 temperature (°C)CRT
334{{0}}Status indication standby setpoint cooling2 Bytes9.1 temperature (°C)CRT
335{{0}}Status indication night setpoint cooling2 Bytes9.1 temperature (°C)CRT
336{{0}}Status indication heat protection setpoint cooling2 Bytes9.1 temperature (°C)CRT
337{{0}}Status indication setpoints cooling8 BytesCRT
338{{0}}Status current setpoint2 Bytes9.1 temperature (°C)CRT
339{{0}}Presence1 Bit1.1 switchCWTU
340{{0}}Lock-up additional step1 Bit1.1 switchCWTU
341{{0}}Heating deactivation1 Bit1.3 enableCWTU
342{{0}}Cooling deactivation1 Bit1.3 enableCWTU
343{{0}}Heating deactivation status1 Bit1.3 enableCRT
344{{0}}Cooling deactivation status1 Bit1.3 enableCRT
345{{0}}Thermostat deactivation1 Bit1.3 enableCWTU
346{{0}}Status indication thermostat deactivation1 Bit1.3 enableCRT
347{{0}}Timer1 Bit1.10 start/stopCWTU
348{{0}}Timer duration3 Bytes10.1 time of dayCWTU
349{{0}}Timer1 Byte20.102 HVAC modeCWTU
350{{0}}Preset 11 Bit1.3 enableCWTU
351{{0}}Preset 21 Bit1.3 enableCWTU
352{{0}}Preset 1 authorization1 Bit1.3 enableCWTU
353{{0}}Preset 2 authorization1 Bit1.3 enableCWTU
354{{0}}Lock-up 11 Bit1.3 enableCWTU
355{{0}}Lock-up 21 Bit1.3 enableCWTU
356{{0}}Status indication lock-up1 Bit1.3 enableCRT
357{{0}}Valve protection date3 Bytes11.1 dateCWTU
358{{0}}Valve protection time3 Bytes10.1 time of dayCWTU
359{{0}}Valve protection date and time8 Bytes19.1 date timeCWTU
360{{0}}Valve protection duration2 Bytes7.6 time (min)CWTU
361{{0}}Valve protection periodicity2 Bytes7.7 time (h)CWTU
362{{0}}Valve protection start/stop1 Bit1.10 start/stopCWTU
363{{0}}Setpoint selection1 Byte20.102 HVAC modeCWTU
364{{0}}Comfort1 Bit1.1 switchCWTU
365{{0}}Standby mode1 Bit1.1 switchCWTU
366{{0}}Night setpoint1 Bit1.1 switchCWTU
367{{0}}Frost/heat protection1 Bit1.1 switchCWTU
368{{0}}Setpoint selection automatic control1 Byte20.102 HVAC modeCWTU
369{{0}}Automatic control deactivation1 Bit1.3 enableCWTU
370{{0}}Heating/Cooling - changeover1 Bit1.100 cooling/heatingCWTU
371{{0}}Priority2 Bit2.2 boolean controlCWTU
372{{0}}Status indication priority1 Bit1.11 stateCWTU
373{{0}}Priority1 Byte20.102 HVAC modeCWTU
374{{0}}Windows contact1 Bit1.19 window/doorCWTU
375{{0}}Scene1 Byte18.1 scene controlCWTU
376{{0}}Status indication setpoint selection1 Byte20.102 HVAC modeCRT
377{{0}}Automatic control deactivation status1 Bit1.3 enableCRT
378{{0}}Heating/Cooling - status indication1 Bit1.100 cooling/heatingCRT
379{{0}}Status indication heating active1 Bit1.11 stateCRT
380{{0}}Status indication cooling active1 Bit1.11 stateCRT
381{{0}}Status indication priority1 Bit1.11 stateCRT
382{{0}}ON/OFF1 Bit1.1 switchCRT
383{{0}}Valve position in %1 Byte5.1 percentage (0..100%)CRT
384{{0}}ON/OFF - basic cooling1 Bit1.1 switchCRT
385{{0}}Valve position in % - basic cooling1 Byte5.1 percentage (0..100%)CRT
386{{0}}ON/OFF - additional heating1 Bit1.1 switchCRT
387{{0}}Valve position in % - additional heating1 Byte5.1 percentage (0..100%)CRT
388{{0}}ON/OFF - additional cooling1 Bit1.1 switchCRT
389{{0}}Valve position in % - additional cooling1 Byte5.1 percentage (0..100%)CRT
390{{0}}Room temperature 12 Bytes9.1 temperature (°C)CWTU
391{{0}}Room temperature 22 Bytes9.1 temperature (°C)CWTU
392{{0}}Room temperature 32 Bytes9.1 temperature (°C)CWTU
393{{0}}Floor temperature2 Bytes9.1 temperature (°C)CWTU
394{{0}}Status indication room temperature2 Bytes9.1 temperature (°C)CRT
395{{0}}Room temperature failure1 Bit1.5 alarmCRT
396{{0}}Minimum room temperature1 Bit1.5 alarmCRT
397{{0}}Maximum room temperature1 Bit1.5 alarmCRT
398{{0}}Ventilation automatic/manual mode1 Bit1.1 switchCWTU
399{{0}}Status ventilation step 1-61 Byte5.10 counter pulses (0..255)CWTU
400{{0}}Status ventilation step 11 Bit1.1 switchCWTU
401{{0}}Status ventilation step 21 Bit1.1 switchCWTU
402{{0}}Status ventilation step 31 Bit1.1 switchCWTU
403{{0}}Status ventilation step 41 Bit1.1 switchCWTU
404{{0}}Status ventilation step 51 Bit1.1 switchCWTU
405{{0}}Status ventilation step 61 Bit1.1 switchCWTU
406{{0}}Ventilation step 1-61 Byte5.10 counter pulses (0..255)CRT
407{{0}}Ventilation step 11 Bit1.1 switchCRT
408{{0}}Ventilation step 21 Bit1.1 switchCRT
409{{0}}Ventilation step 31 Bit1.1 switchCRT
410{{0}}Ventilation step 41 Bit1.1 switchCRT
411{{0}}Ventilation step 51 Bit1.1 switchCRT
412{{0}}Ventilation step 61 Bit1.1 switchCRT
413{{0}}Comfort setpoint heating2 Bytes9.1 temperature (°C)CWTU
413{{0}}Reference setpoint2 Bytes9.1 temperature (°C)CWTU
414{{0}}Standby setpoint heating2 Bytes9.1 temperature (°C)CWTU
415{{0}}Night setpoint heating2 Bytes9.1 temperature (°C)CWTU
416{{0}}Frost protection setpoint heating2 Bytes9.1 temperature (°C)CWTU
417{{0}}Setpoints heating8 BytesCWTU
418{{0}}Comfort setpoint cooling2 Bytes9.1 temperature (°C)CWTU
419{{0}}Standby setpoint cooling2 Bytes9.1 temperature (°C)CWTU
420{{0}}Night setpoint cooling2 Bytes9.1 temperature (°C)CWTU
421{{0}}Heat protection setpoint cooling2 Bytes9.1 temperature (°C)CWTU
422{{0}}Setpoints cooling8 BytesCWTU
423{{0}}Setpoint shift2 Bytes9.2 temperature difference (K)CWTU
424{{0}}Current setpoint2 Bytes9.1 temperature (°C)CWTU
425{{0}}Status indication setpoint shift2 Bytes9.2 temperature difference (K)CRT
426{{0}}Status indication reference setpoint2 Bytes9.1 temperature (°C)CRT
427{{0}}Status indication comfort setpoint heating2 Bytes9.1 temperature (°C)CRT
428{{0}}Status indication standby setpoint heating2 Bytes9.1 temperature (°C)CRT
429{{0}}Status indication night setpoint heating2 Bytes9.1 temperature (°C)CRT
430{{0}}Status indication frost protection setpoint heating2 Bytes9.1 temperature (°C)CRT
431{{0}}Status indication setpoints heating8 BytesCRT
432{{0}}Status indication comfort setpoint cooling2 Bytes9.1 temperature (°C)CRT
433{{0}}Status indication standby setpoint cooling2 Bytes9.1 temperature (°C)CRT
434{{0}}Status indication night setpoint cooling2 Bytes9.1 temperature (°C)CRT
435{{0}}Status indication heat protection setpoint cooling2 Bytes9.1 temperature (°C)CRT
436{{0}}Status indication setpoints cooling8 BytesCRT
437{{0}}Status current setpoint2 Bytes9.1 temperature (°C)CRT
438{{0}}Presence1 Bit1.1 switchCWTU
439{{0}}Lock-up additional step1 Bit1.1 switchCWTU
440{{0}}Heating deactivation1 Bit1.3 enableCWTU
441{{0}}Cooling deactivation1 Bit1.3 enableCWTU
442{{0}}Heating deactivation status1 Bit1.3 enableCRT
443{{0}}Cooling deactivation status1 Bit1.3 enableCRT
444{{0}}Thermostat deactivation1 Bit1.3 enableCWTU
445{{0}}Status indication thermostat deactivation1 Bit1.3 enableCRT
446{{0}}Timer1 Bit1.10 start/stopCWTU
447{{0}}Timer duration3 Bytes10.1 time of dayCWTU
448{{0}}Timer1 Byte20.102 HVAC modeCWTU
449{{0}}Preset 11 Bit1.3 enableCWTU
450{{0}}Preset 21 Bit1.3 enableCWTU
451{{0}}Preset 1 authorization1 Bit1.3 enableCWTU
452{{0}}Preset 2 authorization1 Bit1.3 enableCWTU
453{{0}}Lock-up 11 Bit1.3 enableCWTU
454{{0}}Lock-up 21 Bit1.3 enableCWTU
455{{0}}Status indication lock-up1 Bit1.3 enableCRT
456{{0}}Valve protection date3 Bytes11.1 dateCWTU
457{{0}}Valve protection time3 Bytes10.1 time of dayCWTU
458{{0}}Valve protection date and time8 Bytes19.1 date timeCWTU
459{{0}}Valve protection duration2 Bytes7.6 time (min)CWTU
460{{0}}Valve protection periodicity2 Bytes7.7 time (h)CWTU
461{{0}}Valve protection start/stop1 Bit1.10 start/stopCWTU
462{{0}}Setpoint selection1 Byte20.102 HVAC modeCWTU
463{{0}}Comfort1 Bit1.1 switchCWTU
464{{0}}Standby mode1 Bit1.1 switchCWTU
465{{0}}Night setpoint1 Bit1.1 switchCWTU
466{{0}}Frost/heat protection1 Bit1.1 switchCWTU
467{{0}}Setpoint selection automatic control1 Byte20.102 HVAC modeCWTU
468{{0}}Automatic control deactivation1 Bit1.3 enableCWTU
469{{0}}Heating/Cooling - changeover1 Bit1.100 cooling/heatingCWTU
470{{0}}Priority2 Bit2.2 boolean controlCWTU
471{{0}}Status indication priority1 Bit1.11 stateCWTU
472{{0}}Priority1 Byte20.102 HVAC modeCWTU
473{{0}}Windows contact1 Bit1.19 window/doorCWTU
474{{0}}Scene1 Byte18.1 scene controlCWTU
475{{0}}Status indication setpoint selection1 Byte20.102 HVAC modeCRT
476{{0}}Automatic control deactivation status1 Bit1.3 enableCRT
477{{0}}Heating/Cooling - status indication1 Bit1.100 cooling/heatingCRT
478{{0}}Status indication heating active1 Bit1.11 stateCRT
479{{0}}Status indication cooling active1 Bit1.11 stateCRT
480{{0}}Status indication priority1 Bit1.11 stateCRT
481{{0}}ON/OFF1 Bit1.1 switchCRT
482{{0}}Valve position in %1 Byte5.1 percentage (0..100%)CRT
483{{0}}ON/OFF - basic cooling1 Bit1.1 switchCRT
484{{0}}Valve position in % - basic cooling1 Byte5.1 percentage (0..100%)CRT
485{{0}}ON/OFF - additional heating1 Bit1.1 switchCRT
486{{0}}Valve position in % - additional heating1 Byte5.1 percentage (0..100%)CRT
487{{0}}ON/OFF - additional cooling1 Bit1.1 switchCRT
488{{0}}Valve position in % - additional cooling1 Byte5.1 percentage (0..100%)CRT
489{{0}}Room temperature 12 Bytes9.1 temperature (°C)CWTU
490{{0}}Room temperature 22 Bytes9.1 temperature (°C)CWTU
491{{0}}Room temperature 32 Bytes9.1 temperature (°C)CWTU
492{{0}}Floor temperature2 Bytes9.1 temperature (°C)CWTU
493{{0}}Status indication room temperature2 Bytes9.1 temperature (°C)CRT
494{{0}}Room temperature failure1 Bit1.5 alarmCRT
495{{0}}Minimum room temperature1 Bit1.5 alarmCRT
496{{0}}Maximum room temperature1 Bit1.5 alarmCRT
497{{0}}Ventilation automatic/manual mode1 Bit1.1 switchCWTU
498{{0}}Status ventilation step 1-61 Byte5.10 counter pulses (0..255)CWTU
499{{0}}Status ventilation step 11 Bit1.1 switchCWTU
500{{0}}Status ventilation step 21 Bit1.1 switchCWTU
501{{0}}Status ventilation step 31 Bit1.1 switchCWTU
502{{0}}Status ventilation step 41 Bit1.1 switchCWTU
503{{0}}Status ventilation step 51 Bit1.1 switchCWTU
504{{0}}Status ventilation step 61 Bit1.1 switchCWTU
505{{0}}Ventilation step 1-61 Byte5.10 counter pulses (0..255)CRT
506{{0}}Ventilation step 11 Bit1.1 switchCRT
507{{0}}Ventilation step 21 Bit1.1 switchCRT
508{{0}}Ventilation step 31 Bit1.1 switchCRT
509{{0}}Ventilation step 41 Bit1.1 switchCRT
510{{0}}Ventilation step 51 Bit1.1 switchCRT
511{{0}}Ventilation step 61 Bit1.1 switchCRT
512{{0}}Comfort setpoint heating2 Bytes9.1 temperature (°C)CWTU
512{{0}}Reference setpoint2 Bytes9.1 temperature (°C)CWTU
513{{0}}Standby setpoint heating2 Bytes9.1 temperature (°C)CWTU
514{{0}}Night setpoint heating2 Bytes9.1 temperature (°C)CWTU
515{{0}}Frost protection setpoint heating2 Bytes9.1 temperature (°C)CWTU
516{{0}}Setpoints heating8 BytesCWTU
517{{0}}Comfort setpoint cooling2 Bytes9.1 temperature (°C)CWTU
518{{0}}Standby setpoint cooling2 Bytes9.1 temperature (°C)CWTU
519{{0}}Night setpoint cooling2 Bytes9.1 temperature (°C)CWTU
520{{0}}Heat protection setpoint cooling2 Bytes9.1 temperature (°C)CWTU
521{{0}}Setpoints cooling8 BytesCWTU
522{{0}}Setpoint shift2 Bytes9.2 temperature difference (K)CWTU
523{{0}}Current setpoint2 Bytes9.1 temperature (°C)CWTU
524{{0}}Status indication setpoint shift2 Bytes9.2 temperature difference (K)CRT
525{{0}}Status indication reference setpoint2 Bytes9.1 temperature (°C)CRT
526{{0}}Status indication comfort setpoint heating2 Bytes9.1 temperature (°C)CRT
527{{0}}Status indication standby setpoint heating2 Bytes9.1 temperature (°C)CRT
528{{0}}Status indication night setpoint heating2 Bytes9.1 temperature (°C)CRT
529{{0}}Status indication frost protection setpoint heating2 Bytes9.1 temperature (°C)CRT
530{{0}}Status indication setpoints heating8 BytesCRT
531{{0}}Status indication comfort setpoint cooling2 Bytes9.1 temperature (°C)CRT
532{{0}}Status indication standby setpoint cooling2 Bytes9.1 temperature (°C)CRT
533{{0}}Status indication night setpoint cooling2 Bytes9.1 temperature (°C)CRT
534{{0}}Status indication heat protection setpoint cooling2 Bytes9.1 temperature (°C)CRT
535{{0}}Status indication setpoints cooling8 BytesCRT
536{{0}}Status current setpoint2 Bytes9.1 temperature (°C)CRT
537{{0}}Presence1 Bit1.1 switchCWTU
538{{0}}Lock-up additional step1 Bit1.1 switchCWTU
539{{0}}Heating deactivation1 Bit1.3 enableCWTU
540{{0}}Cooling deactivation1 Bit1.3 enableCWTU
541{{0}}Heating deactivation status1 Bit1.3 enableCRT
542{{0}}Cooling deactivation status1 Bit1.3 enableCRT
543{{0}}Thermostat deactivation1 Bit1.3 enableCWTU
544{{0}}Status indication thermostat deactivation1 Bit1.3 enableCRT
545{{0}}Timer1 Bit1.10 start/stopCWTU
546{{0}}Timer duration3 Bytes10.1 time of dayCWTU
547{{0}}Timer1 Byte20.102 HVAC modeCWTU
548{{0}}Preset 11 Bit1.3 enableCWTU
549{{0}}Preset 21 Bit1.3 enableCWTU
550{{0}}Preset 1 authorization1 Bit1.3 enableCWTU
551{{0}}Preset 2 authorization1 Bit1.3 enableCWTU
552{{0}}Lock-up 11 Bit1.3 enableCWTU
553{{0}}Lock-up 21 Bit1.3 enableCWTU
554{{0}}Status indication lock-up1 Bit1.3 enableCRT
555{{0}}Valve protection date3 Bytes11.1 dateCWTU
556{{0}}Valve protection time3 Bytes10.1 time of dayCWTU
557{{0}}Valve protection date and time8 Bytes19.1 date timeCWTU
558{{0}}Valve protection duration2 Bytes7.6 time (min)CWTU
559{{0}}Valve protection periodicity2 Bytes7.7 time (h)CWTU
560{{0}}Valve protection start/stop1 Bit1.10 start/stopCWTU
561{{0}}Setpoint selection1 Byte20.102 HVAC modeCWTU
562{{0}}Comfort1 Bit1.1 switchCWTU
563{{0}}Standby mode1 Bit1.1 switchCWTU
564{{0}}Night setpoint1 Bit1.1 switchCWTU
565{{0}}Frost/heat protection1 Bit1.1 switchCWTU
566{{0}}Setpoint selection automatic control1 Byte20.102 HVAC modeCWTU
567{{0}}Automatic control deactivation1 Bit1.3 enableCWTU
568{{0}}Heating/Cooling - changeover1 Bit1.100 cooling/heatingCWTU
569{{0}}Priority2 Bit2.2 boolean controlCWTU
570{{0}}Status indication priority1 Bit1.11 stateCWTU
571{{0}}Priority1 Byte20.102 HVAC modeCWTU
572{{0}}Windows contact1 Bit1.19 window/doorCWTU
573{{0}}Scene1 Byte18.1 scene controlCWTU
574{{0}}Status indication setpoint selection1 Byte20.102 HVAC modeCRT
575{{0}}Automatic control deactivation status1 Bit1.3 enableCRT
576{{0}}Heating/Cooling - status indication1 Bit1.100 cooling/heatingCRT
577{{0}}Status indication heating active1 Bit1.11 stateCRT
578{{0}}Status indication cooling active1 Bit1.11 stateCRT
579{{0}}Status indication priority1 Bit1.11 stateCRT
580{{0}}ON/OFF1 Bit1.1 switchCRT
581{{0}}Valve position in %1 Byte5.1 percentage (0..100%)CRT
582{{0}}ON/OFF - basic cooling1 Bit1.1 switchCRT
583{{0}}Valve position in % - basic cooling1 Byte5.1 percentage (0..100%)CRT
584{{0}}ON/OFF - additional heating1 Bit1.1 switchCRT
585{{0}}Valve position in % - additional heating1 Byte5.1 percentage (0..100%)CRT
586{{0}}ON/OFF - additional cooling1 Bit1.1 switchCRT
587{{0}}Valve position in % - additional cooling1 Byte5.1 percentage (0..100%)CRT
588{{0}}Room temperature 12 Bytes9.1 temperature (°C)CWTU
589{{0}}Room temperature 22 Bytes9.1 temperature (°C)CWTU
590{{0}}Room temperature 32 Bytes9.1 temperature (°C)CWTU
591{{0}}Floor temperature2 Bytes9.1 temperature (°C)CWTU
592{{0}}Status indication room temperature2 Bytes9.1 temperature (°C)CRT
593{{0}}Room temperature failure1 Bit1.5 alarmCRT
594{{0}}Minimum room temperature1 Bit1.5 alarmCRT
595{{0}}Maximum room temperature1 Bit1.5 alarmCRT
596{{0}}Ventilation automatic/manual mode1 Bit1.1 switchCWTU
597{{0}}Status ventilation step 1-61 Byte5.10 counter pulses (0..255)CWTU
598{{0}}Status ventilation step 11 Bit1.1 switchCWTU
599{{0}}Status ventilation step 21 Bit1.1 switchCWTU
600{{0}}Status ventilation step 31 Bit1.1 switchCWTU
601{{0}}Status ventilation step 41 Bit1.1 switchCWTU
602{{0}}Status ventilation step 51 Bit1.1 switchCWTU
603{{0}}Status ventilation step 61 Bit1.1 switchCWTU
604{{0}}Ventilation step 1-61 Byte5.10 counter pulses (0..255)CRT
605{{0}}Ventilation step 11 Bit1.1 switchCRT
606{{0}}Ventilation step 21 Bit1.1 switchCRT
607{{0}}Ventilation step 31 Bit1.1 switchCRT
608{{0}}Ventilation step 41 Bit1.1 switchCRT
609{{0}}Ventilation step 51 Bit1.1 switchCRT
610{{0}}Ventilation step 61 Bit1.1 switchCRT
611{{0}}Comfort setpoint heating2 Bytes9.1 temperature (°C)CWTU
611{{0}}Reference setpoint2 Bytes9.1 temperature (°C)CWTU
612{{0}}Standby setpoint heating2 Bytes9.1 temperature (°C)CWTU
613{{0}}Night setpoint heating2 Bytes9.1 temperature (°C)CWTU
614{{0}}Frost protection setpoint heating2 Bytes9.1 temperature (°C)CWTU
615{{0}}Setpoints heating8 BytesCWTU
616{{0}}Comfort setpoint cooling2 Bytes9.1 temperature (°C)CWTU
617{{0}}Standby setpoint cooling2 Bytes9.1 temperature (°C)CWTU
618{{0}}Night setpoint cooling2 Bytes9.1 temperature (°C)CWTU
619{{0}}Heat protection setpoint cooling2 Bytes9.1 temperature (°C)CWTU
620{{0}}Setpoints cooling8 BytesCWTU
621{{0}}Setpoint shift2 Bytes9.2 temperature difference (K)CWTU
622{{0}}Current setpoint2 Bytes9.1 temperature (°C)CWTU
623{{0}}Status indication setpoint shift2 Bytes9.2 temperature difference (K)CRT
624{{0}}Status indication reference setpoint2 Bytes9.1 temperature (°C)CRT
625{{0}}Status indication comfort setpoint heating2 Bytes9.1 temperature (°C)CRT
626{{0}}Status indication standby setpoint heating2 Bytes9.1 temperature (°C)CRT
627{{0}}Status indication night setpoint heating2 Bytes9.1 temperature (°C)CRT
628{{0}}Status indication frost protection setpoint heating2 Bytes9.1 temperature (°C)CRT
629{{0}}Status indication setpoints heating8 BytesCRT
630{{0}}Status indication comfort setpoint cooling2 Bytes9.1 temperature (°C)CRT
631{{0}}Status indication standby setpoint cooling2 Bytes9.1 temperature (°C)CRT
632{{0}}Status indication night setpoint cooling2 Bytes9.1 temperature (°C)CRT
633{{0}}Status indication heat protection setpoint cooling2 Bytes9.1 temperature (°C)CRT
634{{0}}Status indication setpoints cooling8 BytesCRT
635{{0}}Status current setpoint2 Bytes9.1 temperature (°C)CRT
636{{0}}Presence1 Bit1.1 switchCWTU
637{{0}}Lock-up additional step1 Bit1.1 switchCWTU
638{{0}}Heating deactivation1 Bit1.3 enableCWTU
639{{0}}Cooling deactivation1 Bit1.3 enableCWTU
640{{0}}Heating deactivation status1 Bit1.3 enableCRT
641{{0}}Cooling deactivation status1 Bit1.3 enableCRT
642{{0}}Thermostat deactivation1 Bit1.3 enableCWTU
643{{0}}Status indication thermostat deactivation1 Bit1.3 enableCRT
644{{0}}Timer1 Bit1.10 start/stopCWTU
645{{0}}Timer duration3 Bytes10.1 time of dayCWTU
646{{0}}Timer1 Byte20.102 HVAC modeCWTU
647{{0}}Preset 11 Bit1.3 enableCWTU
648{{0}}Preset 21 Bit1.3 enableCWTU
649{{0}}Preset 1 authorization1 Bit1.3 enableCWTU
650{{0}}Preset 2 authorization1 Bit1.3 enableCWTU
651{{0}}Lock-up 11 Bit1.3 enableCWTU
652{{0}}Lock-up 21 Bit1.3 enableCWTU
653{{0}}Status indication lock-up1 Bit1.3 enableCRT
654{{0}}Valve protection date3 Bytes11.1 dateCWTU
655{{0}}Valve protection time3 Bytes10.1 time of dayCWTU
656{{0}}Valve protection date and time8 Bytes19.1 date timeCWTU
657{{0}}Valve protection duration2 Bytes7.6 time (min)CWTU
658{{0}}Valve protection periodicity2 Bytes7.7 time (h)CWTU
659{{0}}Valve protection start/stop1 Bit1.10 start/stopCWTU
660{{0}}Setpoint selection1 Byte20.102 HVAC modeCWTU
661{{0}}Comfort1 Bit1.1 switchCWTU
662{{0}}Standby mode1 Bit1.1 switchCWTU
663{{0}}Night setpoint1 Bit1.1 switchCWTU
664{{0}}Frost/heat protection1 Bit1.1 switchCWTU
665{{0}}Setpoint selection automatic control1 Byte20.102 HVAC modeCWTU
666{{0}}Automatic control deactivation1 Bit1.3 enableCWTU
667{{0}}Heating/Cooling - changeover1 Bit1.100 cooling/heatingCWTU
668{{0}}Priority2 Bit2.2 boolean controlCWTU
669{{0}}Status indication priority1 Bit1.11 stateCWTU
670{{0}}Priority1 Byte20.102 HVAC modeCWTU
671{{0}}Windows contact1 Bit1.19 window/doorCWTU
672{{0}}Scene1 Byte18.1 scene controlCWTU
673{{0}}Status indication setpoint selection1 Byte20.102 HVAC modeCRT
674{{0}}Automatic control deactivation status1 Bit1.3 enableCRT
675{{0}}Heating/Cooling - status indication1 Bit1.100 cooling/heatingCRT
676{{0}}Status indication heating active1 Bit1.11 stateCRT
677{{0}}Status indication cooling active1 Bit1.11 stateCRT
678{{0}}Status indication priority1 Bit1.11 stateCRT
679{{0}}ON/OFF1 Bit1.1 switchCRT
680{{0}}Valve position in %1 Byte5.1 percentage (0..100%)CRT
681{{0}}ON/OFF - basic cooling1 Bit1.1 switchCRT
682{{0}}Valve position in % - basic cooling1 Byte5.1 percentage (0..100%)CRT
683{{0}}ON/OFF - additional heating1 Bit1.1 switchCRT
684{{0}}Valve position in % - additional heating1 Byte5.1 percentage (0..100%)CRT
685{{0}}ON/OFF - additional cooling1 Bit1.1 switchCRT
686{{0}}Valve position in % - additional cooling1 Byte5.1 percentage (0..100%)CRT
687{{0}}Room temperature 12 Bytes9.1 temperature (°C)CWTU
688{{0}}Room temperature 22 Bytes9.1 temperature (°C)CWTU
689{{0}}Room temperature 32 Bytes9.1 temperature (°C)CWTU
690{{0}}Floor temperature2 Bytes9.1 temperature (°C)CWTU
691{{0}}Status indication room temperature2 Bytes9.1 temperature (°C)CRT
692{{0}}Room temperature failure1 Bit1.5 alarmCRT
693{{0}}Minimum room temperature1 Bit1.5 alarmCRT
694{{0}}Maximum room temperature1 Bit1.5 alarmCRT
695{{0}}Ventilation automatic/manual mode1 Bit1.1 switchCWTU
696{{0}}Status ventilation step 1-61 Byte5.10 counter pulses (0..255)CWTU
697{{0}}Status ventilation step 11 Bit1.1 switchCWTU
698{{0}}Status ventilation step 21 Bit1.1 switchCWTU
699{{0}}Status ventilation step 31 Bit1.1 switchCWTU
700{{0}}Status ventilation step 41 Bit1.1 switchCWTU
701{{0}}Status ventilation step 51 Bit1.1 switchCWTU
702{{0}}Status ventilation step 61 Bit1.1 switchCWTU
703{{0}}Ventilation step 1-61 Byte5.10 counter pulses (0..255)CRT
704{{0}}Ventilation step 11 Bit1.1 switchCRT
705{{0}}Ventilation step 21 Bit1.1 switchCRT
706{{0}}Ventilation step 31 Bit1.1 switchCRT
707{{0}}Ventilation step 41 Bit1.1 switchCRT
708{{0}}Ventilation step 51 Bit1.1 switchCRT
709{{0}}Ventilation step 61 Bit1.1 switchCRT
710{{0}}Comfort setpoint heating2 Bytes9.1 temperature (°C)CWTU
710{{0}}Reference setpoint2 Bytes9.1 temperature (°C)CWTU
711{{0}}Standby setpoint heating2 Bytes9.1 temperature (°C)CWTU
712{{0}}Night setpoint heating2 Bytes9.1 temperature (°C)CWTU
713{{0}}Frost protection setpoint heating2 Bytes9.1 temperature (°C)CWTU
714{{0}}Setpoints heating8 BytesCWTU
715{{0}}Comfort setpoint cooling2 Bytes9.1 temperature (°C)CWTU
716{{0}}Standby setpoint cooling2 Bytes9.1 temperature (°C)CWTU
717{{0}}Night setpoint cooling2 Bytes9.1 temperature (°C)CWTU
718{{0}}Heat protection setpoint cooling2 Bytes9.1 temperature (°C)CWTU
719{{0}}Setpoints cooling8 BytesCWTU
720{{0}}Setpoint shift2 Bytes9.2 temperature difference (K)CWTU
721{{0}}Current setpoint2 Bytes9.1 temperature (°C)CWTU
722{{0}}Status indication setpoint shift2 Bytes9.2 temperature difference (K)CRT
723{{0}}Status indication reference setpoint2 Bytes9.1 temperature (°C)CRT
724{{0}}Status indication comfort setpoint heating2 Bytes9.1 temperature (°C)CRT
725{{0}}Status indication standby setpoint heating2 Bytes9.1 temperature (°C)CRT
726{{0}}Status indication night setpoint heating2 Bytes9.1 temperature (°C)CRT
727{{0}}Status indication frost protection setpoint heating2 Bytes9.1 temperature (°C)CRT
728{{0}}Status indication setpoints heating8 BytesCRT
729{{0}}Status indication comfort setpoint cooling2 Bytes9.1 temperature (°C)CRT
730{{0}}Status indication standby setpoint cooling2 Bytes9.1 temperature (°C)CRT
731{{0}}Status indication night setpoint cooling2 Bytes9.1 temperature (°C)CRT
732{{0}}Status indication heat protection setpoint cooling2 Bytes9.1 temperature (°C)CRT
733{{0}}Status indication setpoints cooling8 BytesCRT
734{{0}}Status current setpoint2 Bytes9.1 temperature (°C)CRT
735{{0}}Presence1 Bit1.1 switchCWTU
736{{0}}Lock-up additional step1 Bit1.1 switchCWTU
737{{0}}Heating deactivation1 Bit1.3 enableCWTU
738{{0}}Cooling deactivation1 Bit1.3 enableCWTU
739{{0}}Heating deactivation status1 Bit1.3 enableCRT
740{{0}}Cooling deactivation status1 Bit1.3 enableCRT
741{{0}}Thermostat deactivation1 Bit1.3 enableCWTU
742{{0}}Status indication thermostat deactivation1 Bit1.3 enableCRT
743{{0}}Timer1 Bit1.10 start/stopCWTU
744{{0}}Timer duration3 Bytes10.1 time of dayCWTU
745{{0}}Timer1 Byte20.102 HVAC modeCWTU
746{{0}}Preset 11 Bit1.3 enableCWTU
747{{0}}Preset 21 Bit1.3 enableCWTU
748{{0}}Preset 1 authorization1 Bit1.3 enableCWTU
749{{0}}Preset 2 authorization1 Bit1.3 enableCWTU
750{{0}}Lock-up 11 Bit1.3 enableCWTU
751{{0}}Lock-up 21 Bit1.3 enableCWTU
752{{0}}Status indication lock-up1 Bit1.3 enableCRT
753{{0}}Valve protection date3 Bytes11.1 dateCWTU
754{{0}}Valve protection time3 Bytes10.1 time of dayCWTU
755{{0}}Valve protection date and time8 Bytes19.1 date timeCWTU
756{{0}}Valve protection duration2 Bytes7.6 time (min)CWTU
757{{0}}Valve protection periodicity2 Bytes7.7 time (h)CWTU
758{{0}}Valve protection start/stop1 Bit1.10 start/stopCWTU
759{{0}}Setpoint selection1 Byte20.102 HVAC modeCWTU
760{{0}}Comfort1 Bit1.1 switchCWTU
761{{0}}Standby mode1 Bit1.1 switchCWTU
762{{0}}Night setpoint1 Bit1.1 switchCWTU
763{{0}}Frost/heat protection1 Bit1.1 switchCWTU
764{{0}}Setpoint selection automatic control1 Byte20.102 HVAC modeCWTU
765{{0}}Automatic control deactivation1 Bit1.3 enableCWTU
766{{0}}Heating/Cooling - changeover1 Bit1.100 cooling/heatingCWTU
767{{0}}Priority2 Bit2.2 boolean controlCWTU
768{{0}}Status indication priority1 Bit1.11 stateCWTU
769{{0}}Priority1 Byte20.102 HVAC modeCWTU
770{{0}}Windows contact1 Bit1.19 window/doorCWTU
771{{0}}Scene1 Byte18.1 scene controlCWTU
772{{0}}Status indication setpoint selection1 Byte20.102 HVAC modeCRT
773{{0}}Automatic control deactivation status1 Bit1.3 enableCRT
774{{0}}Heating/Cooling - status indication1 Bit1.100 cooling/heatingCRT
775{{0}}Status indication heating active1 Bit1.11 stateCRT
776{{0}}Status indication cooling active1 Bit1.11 stateCRT
777{{0}}Status indication priority1 Bit1.11 stateCRT
778{{0}}ON/OFF1 Bit1.1 switchCRT
779{{0}}Valve position in %1 Byte5.1 percentage (0..100%)CRT
780{{0}}ON/OFF - basic cooling1 Bit1.1 switchCRT
781{{0}}Valve position in % - basic cooling1 Byte5.1 percentage (0..100%)CRT
782{{0}}ON/OFF - additional heating1 Bit1.1 switchCRT
783{{0}}Valve position in % - additional heating1 Byte5.1 percentage (0..100%)CRT
784{{0}}ON/OFF - additional cooling1 Bit1.1 switchCRT
785{{0}}Valve position in % - additional cooling1 Byte5.1 percentage (0..100%)CRT
786{{0}}Room temperature 12 Bytes9.1 temperature (°C)CWTU
787{{0}}Room temperature 22 Bytes9.1 temperature (°C)CWTU
788{{0}}Room temperature 32 Bytes9.1 temperature (°C)CWTU
789{{0}}Floor temperature2 Bytes9.1 temperature (°C)CWTU
790{{0}}Status indication room temperature2 Bytes9.1 temperature (°C)CRT
791{{0}}Room temperature failure1 Bit1.5 alarmCRT
792{{0}}Minimum room temperature1 Bit1.5 alarmCRT
793{{0}}Maximum room temperature1 Bit1.5 alarmCRT
794{{0}}Ventilation automatic/manual mode1 Bit1.1 switchCWTU
795{{0}}Status ventilation step 1-61 Byte5.10 counter pulses (0..255)CWTU
796{{0}}Status ventilation step 11 Bit1.1 switchCWTU
797{{0}}Status ventilation step 21 Bit1.1 switchCWTU
798{{0}}Status ventilation step 31 Bit1.1 switchCWTU
799{{0}}Status ventilation step 41 Bit1.1 switchCWTU
800{{0}}Status ventilation step 51 Bit1.1 switchCWTU
801{{0}}Status ventilation step 61 Bit1.1 switchCWTU
802{{0}}Ventilation step 1-61 Byte5.10 counter pulses (0..255)CRT
803{{0}}Ventilation step 11 Bit1.1 switchCRT
804{{0}}Ventilation step 21 Bit1.1 switchCRT
805{{0}}Ventilation step 31 Bit1.1 switchCRT
806{{0}}Ventilation step 41 Bit1.1 switchCRT
807{{0}}Ventilation step 51 Bit1.1 switchCRT
808{{0}}Ventilation step 61 Bit1.1 switchCRT
809{{0}}Comfort setpoint heating2 Bytes9.1 temperature (°C)CWTU
809{{0}}Reference setpoint2 Bytes9.1 temperature (°C)CWTU
810{{0}}Standby setpoint heating2 Bytes9.1 temperature (°C)CWTU
811{{0}}Night setpoint heating2 Bytes9.1 temperature (°C)CWTU
812{{0}}Frost protection setpoint heating2 Bytes9.1 temperature (°C)CWTU
813{{0}}Setpoints heating8 BytesCWTU
814{{0}}Comfort setpoint cooling2 Bytes9.1 temperature (°C)CWTU
815{{0}}Standby setpoint cooling2 Bytes9.1 temperature (°C)CWTU
816{{0}}Night setpoint cooling2 Bytes9.1 temperature (°C)CWTU
817{{0}}Heat protection setpoint cooling2 Bytes9.1 temperature (°C)CWTU
818{{0}}Setpoints cooling8 BytesCWTU
819{{0}}Setpoint shift2 Bytes9.2 temperature difference (K)CWTU
820{{0}}Current setpoint2 Bytes9.1 temperature (°C)CWTU
821{{0}}Status indication setpoint shift2 Bytes9.2 temperature difference (K)CRT
822{{0}}Status indication reference setpoint2 Bytes9.1 temperature (°C)CRT
823{{0}}Status indication comfort setpoint heating2 Bytes9.1 temperature (°C)CRT
824{{0}}Status indication standby setpoint heating2 Bytes9.1 temperature (°C)CRT
825{{0}}Status indication night setpoint heating2 Bytes9.1 temperature (°C)CRT
826{{0}}Status indication frost protection setpoint heating2 Bytes9.1 temperature (°C)CRT
827{{0}}Status indication setpoints heating8 BytesCRT
828{{0}}Status indication comfort setpoint cooling2 Bytes9.1 temperature (°C)CRT
829{{0}}Status indication standby setpoint cooling2 Bytes9.1 temperature (°C)CRT
830{{0}}Status indication night setpoint cooling2 Bytes9.1 temperature (°C)CRT
831{{0}}Status indication heat protection setpoint cooling2 Bytes9.1 temperature (°C)CRT
832{{0}}Status indication setpoints cooling8 BytesCRT
833{{0}}Status current setpoint2 Bytes9.1 temperature (°C)CRT
834{{0}}Presence1 Bit1.1 switchCWTU
835{{0}}Lock-up additional step1 Bit1.1 switchCWTU
836{{0}}Heating deactivation1 Bit1.3 enableCWTU
837{{0}}Cooling deactivation1 Bit1.3 enableCWTU
838{{0}}Heating deactivation status1 Bit1.3 enableCRT
839{{0}}Cooling deactivation status1 Bit1.3 enableCRT
840{{0}}Thermostat deactivation1 Bit1.3 enableCWTU
841{{0}}Status indication thermostat deactivation1 Bit1.3 enableCRT
842{{0}}Timer1 Bit1.10 start/stopCWTU
843{{0}}Timer duration3 Bytes10.1 time of dayCWTU
844{{0}}Timer1 Byte20.102 HVAC modeCWTU
845{{0}}Preset 11 Bit1.3 enableCWTU
846{{0}}Preset 21 Bit1.3 enableCWTU
847{{0}}Preset 1 authorization1 Bit1.3 enableCWTU
848{{0}}Preset 2 authorization1 Bit1.3 enableCWTU
849{{0}}Lock-up 11 Bit1.3 enableCWTU
850{{0}}Lock-up 21 Bit1.3 enableCWTU
851{{0}}Status indication lock-up1 Bit1.3 enableCRT
852{{0}}Valve protection date3 Bytes11.1 dateCWTU
853{{0}}Valve protection time3 Bytes10.1 time of dayCWTU
854{{0}}Valve protection date and time8 Bytes19.1 date timeCWTU
855{{0}}Valve protection duration2 Bytes7.6 time (min)CWTU
856{{0}}Valve protection periodicity2 Bytes7.7 time (h)CWTU
857{{0}}Valve protection start/stop1 Bit1.10 start/stopCWTU
858{{0}}Setpoint selection1 Byte20.102 HVAC modeCWTU
859{{0}}Comfort1 Bit1.1 switchCWTU
860{{0}}Standby mode1 Bit1.1 switchCWTU
861{{0}}Night setpoint1 Bit1.1 switchCWTU
862{{0}}Frost/heat protection1 Bit1.1 switchCWTU
863{{0}}Setpoint selection automatic control1 Byte20.102 HVAC modeCWTU
864{{0}}Automatic control deactivation1 Bit1.3 enableCWTU
865{{0}}Heating/Cooling - changeover1 Bit1.100 cooling/heatingCWTU
866{{0}}Priority2 Bit2.2 boolean controlCWTU
867{{0}}Status indication priority1 Bit1.11 stateCWTU
868{{0}}Priority1 Byte20.102 HVAC modeCWTU
869{{0}}Windows contact1 Bit1.19 window/doorCWTU
870{{0}}Scene1 Byte18.1 scene controlCWTU
871{{0}}Status indication setpoint selection1 Byte20.102 HVAC modeCRT
872{{0}}Automatic control deactivation status1 Bit1.3 enableCRT
873{{0}}Heating/Cooling - status indication1 Bit1.100 cooling/heatingCRT
874{{0}}Status indication heating active1 Bit1.11 stateCRT
875{{0}}Status indication cooling active1 Bit1.11 stateCRT
876{{0}}Status indication priority1 Bit1.11 stateCRT
877{{0}}ON/OFF1 Bit1.1 switchCRT
878{{0}}Valve position in %1 Byte5.1 percentage (0..100%)CRT
879{{0}}ON/OFF - basic cooling1 Bit1.1 switchCRT
880{{0}}Valve position in % - basic cooling1 Byte5.1 percentage (0..100%)CRT
881{{0}}ON/OFF - additional heating1 Bit1.1 switchCRT
882{{0}}Valve position in % - additional heating1 Byte5.1 percentage (0..100%)CRT
883{{0}}ON/OFF - additional cooling1 Bit1.1 switchCRT
884{{0}}Valve position in % - additional cooling1 Byte5.1 percentage (0..100%)CRT
885{{0}}Room temperature 12 Bytes9.1 temperature (°C)CWTU
886{{0}}Room temperature 22 Bytes9.1 temperature (°C)CWTU
887{{0}}Room temperature 32 Bytes9.1 temperature (°C)CWTU
888{{0}}Floor temperature2 Bytes9.1 temperature (°C)CWTU
889{{0}}Status indication room temperature2 Bytes9.1 temperature (°C)CRT
890{{0}}Room temperature failure1 Bit1.5 alarmCRT
891{{0}}Minimum room temperature1 Bit1.5 alarmCRT
892{{0}}Maximum room temperature1 Bit1.5 alarmCRT
893{{0}}Ventilation automatic/manual mode1 Bit1.1 switchCWTU
894{{0}}Status ventilation step 1-61 Byte5.10 counter pulses (0..255)CWTU
895{{0}}Status ventilation step 11 Bit1.1 switchCWTU
896{{0}}Status ventilation step 21 Bit1.1 switchCWTU
897{{0}}Status ventilation step 31 Bit1.1 switchCWTU
898{{0}}Status ventilation step 41 Bit1.1 switchCWTU
899{{0}}Status ventilation step 51 Bit1.1 switchCWTU
900{{0}}Status ventilation step 61 Bit1.1 switchCWTU
901{{0}}Ventilation step 1-61 Byte5.10 counter pulses (0..255)CRT
902{{0}}Ventilation step 11 Bit1.1 switchCRT
903{{0}}Ventilation step 21 Bit1.1 switchCRT
904{{0}}Ventilation step 31 Bit1.1 switchCRT
905{{0}}Ventilation step 41 Bit1.1 switchCRT
906{{0}}Ventilation step 51 Bit1.1 switchCRT
907{{0}}Ventilation step 61 Bit1.1 switchCRT
908{{0}}Comfort setpoint heating2 Bytes9.1 temperature (°C)CWTU
908{{0}}Reference setpoint2 Bytes9.1 temperature (°C)CWTU
909{{0}}Standby setpoint heating2 Bytes9.1 temperature (°C)CWTU
910{{0}}Night setpoint heating2 Bytes9.1 temperature (°C)CWTU
911{{0}}Frost protection setpoint heating2 Bytes9.1 temperature (°C)CWTU
912{{0}}Setpoints heating8 BytesCWTU
913{{0}}Comfort setpoint cooling2 Bytes9.1 temperature (°C)CWTU
914{{0}}Standby setpoint cooling2 Bytes9.1 temperature (°C)CWTU
915{{0}}Night setpoint cooling2 Bytes9.1 temperature (°C)CWTU
916{{0}}Heat protection setpoint cooling2 Bytes9.1 temperature (°C)CWTU
917{{0}}Setpoints cooling8 BytesCWTU
918{{0}}Setpoint shift2 Bytes9.2 temperature difference (K)CWTU
919{{0}}Current setpoint2 Bytes9.1 temperature (°C)CWTU
920{{0}}Status indication setpoint shift2 Bytes9.2 temperature difference (K)CRT
921{{0}}Status indication reference setpoint2 Bytes9.1 temperature (°C)CRT
922{{0}}Status indication comfort setpoint heating2 Bytes9.1 temperature (°C)CRT
923{{0}}Status indication standby setpoint heating2 Bytes9.1 temperature (°C)CRT
924{{0}}Status indication night setpoint heating2 Bytes9.1 temperature (°C)CRT
925{{0}}Status indication frost protection setpoint heating2 Bytes9.1 temperature (°C)CRT
926{{0}}Status indication setpoints heating8 BytesCRT
927{{0}}Status indication comfort setpoint cooling2 Bytes9.1 temperature (°C)CRT
928{{0}}Status indication standby setpoint cooling2 Bytes9.1 temperature (°C)CRT
929{{0}}Status indication night setpoint cooling2 Bytes9.1 temperature (°C)CRT
930{{0}}Status indication heat protection setpoint cooling2 Bytes9.1 temperature (°C)CRT
931{{0}}Status indication setpoints cooling8 BytesCRT
932{{0}}Status current setpoint2 Bytes9.1 temperature (°C)CRT
933{{0}}Presence1 Bit1.1 switchCWTU
934{{0}}Lock-up additional step1 Bit1.1 switchCWTU
935{{0}}Heating deactivation1 Bit1.3 enableCWTU
936{{0}}Cooling deactivation1 Bit1.3 enableCWTU
937{{0}}Heating deactivation status1 Bit1.3 enableCRT
938{{0}}Cooling deactivation status1 Bit1.3 enableCRT
939{{0}}Thermostat deactivation1 Bit1.3 enableCWTU
940{{0}}Status indication thermostat deactivation1 Bit1.3 enableCRT
941{{0}}Timer1 Bit1.10 start/stopCWTU
942{{0}}Timer duration3 Bytes10.1 time of dayCWTU
943{{0}}Timer1 Byte20.102 HVAC modeCWTU
944{{0}}Preset 11 Bit1.3 enableCWTU
945{{0}}Preset 21 Bit1.3 enableCWTU
946{{0}}Preset 1 authorization1 Bit1.3 enableCWTU
947{{0}}Preset 2 authorization1 Bit1.3 enableCWTU
948{{0}}Lock-up 11 Bit1.3 enableCWTU
949{{0}}Lock-up 21 Bit1.3 enableCWTU
950{{0}}Status indication lock-up1 Bit1.3 enableCRT
951{{0}}Valve protection date3 Bytes11.1 dateCWTU
952{{0}}Valve protection time3 Bytes10.1 time of dayCWTU
953{{0}}Valve protection date and time8 Bytes19.1 date timeCWTU
954{{0}}Valve protection duration2 Bytes7.6 time (min)CWTU
955{{0}}Valve protection periodicity2 Bytes7.7 time (h)CWTU
956{{0}}Valve protection start/stop1 Bit1.10 start/stopCWTU
957{{0}}Setpoint selection1 Byte20.102 HVAC modeCWTU
958{{0}}Comfort1 Bit1.1 switchCWTU
959{{0}}Standby mode1 Bit1.1 switchCWTU
960{{0}}Night setpoint1 Bit1.1 switchCWTU
961{{0}}Frost/heat protection1 Bit1.1 switchCWTU
962{{0}}Setpoint selection automatic control1 Byte20.102 HVAC modeCWTU
963{{0}}Automatic control deactivation1 Bit1.3 enableCWTU
964{{0}}Heating/Cooling - changeover1 Bit1.100 cooling/heatingCWTU
965{{0}}Priority2 Bit2.2 boolean controlCWTU
966{{0}}Status indication priority1 Bit1.11 stateCWTU
967{{0}}Priority1 Byte20.102 HVAC modeCWTU
968{{0}}Windows contact1 Bit1.19 window/doorCWTU
969{{0}}Scene1 Byte18.1 scene controlCWTU
970{{0}}Status indication setpoint selection1 Byte20.102 HVAC modeCRT
971{{0}}Automatic control deactivation status1 Bit1.3 enableCRT
972{{0}}Heating/Cooling - status indication1 Bit1.100 cooling/heatingCRT
973{{0}}Status indication heating active1 Bit1.11 stateCRT
974{{0}}Status indication cooling active1 Bit1.11 stateCRT
975{{0}}Status indication priority1 Bit1.11 stateCRT
976{{0}}ON/OFF1 Bit1.1 switchCRT
977{{0}}Valve position in %1 Byte5.1 percentage (0..100%)CRT
978{{0}}ON/OFF - basic cooling1 Bit1.1 switchCRT
979{{0}}Valve position in % - basic cooling1 Byte5.1 percentage (0..100%)CRT
980{{0}}ON/OFF - additional heating1 Bit1.1 switchCRT
981{{0}}Valve position in % - additional heating1 Byte5.1 percentage (0..100%)CRT
982{{0}}ON/OFF - additional cooling1 Bit1.1 switchCRT
983{{0}}Valve position in % - additional cooling1 Byte5.1 percentage (0..100%)CRT
984{{0}}Room temperature 12 Bytes9.1 temperature (°C)CWTU
985{{0}}Room temperature 22 Bytes9.1 temperature (°C)CWTU
986{{0}}Room temperature 32 Bytes9.1 temperature (°C)CWTU
987{{0}}Floor temperature2 Bytes9.1 temperature (°C)CWTU
988{{0}}Status indication room temperature2 Bytes9.1 temperature (°C)CRT
989{{0}}Room temperature failure1 Bit1.5 alarmCRT
990{{0}}Minimum room temperature1 Bit1.5 alarmCRT
991{{0}}Maximum room temperature1 Bit1.5 alarmCRT
992{{0}}Ventilation automatic/manual mode1 Bit1.1 switchCWTU

First 1000 of 1369 group objects shown. Download the .knxprod for the full list.

Parameters (321)
ParameterTypeDefault
Output 1 nametextOutput 1
Output 2 nametextOutput 2
Output 3 nametextOutput 3
Output 4 nametextOutput 4
Output 5 nametextOutput 5
Output 6 nametextOutput 6
Priority between lock-up 1 and lock-up 2unsignedInt 0…2551
Thermostat 1 nametextThermostat 1
Thermostat 2 nametextThermostat 2
Thermostat 3 nametextThermostat 3
Thermostat 4 nametextThermostat 4
Thermostat 5 nametextThermostat 5
Thermostat 6 nametextThermostat 6
Thermostat 7 nametextThermostat 7
Thermostat 8 nametextThermostat 8
Thermostat 9 nametextThermostat 9
Thermostat 10 nametextThermostat 10
Thermostat 11 nametextThermostat 11
Thermostat 12 nametextThermostat 12
Function selectionlistHeating
Status after resetlistStatus before reset
Heat/cool mode after resetlistOperating mode before reset
Valve protectionlistPeriodically
ThresholdunsignedInt 0…255204
PeriodicitylistEvery week
Type of heating controllistSwitching PI-control (PWM)
Cycle timelist15 min
Hysteresislist+/-0,5K
Hysteresis durationlist5 min
Type of heating equipmentlistWarm water heating
Type of cooling controllistSwitching PI-control (PWM)
Hysteresislist+/-0,3K
Type of cooling equipmentlistCooling ceiling
Timeout of room temperaturetime45
Floor temperature detectionunsignedInt 0…2551
Timeout of floor temperatureunsignedInt 0…25545
Maximum floor temperatureunsignedInt 24…4628
Minimum room temperatureunsignedInt 0…407
Maximum room temperatureunsignedInt 0…4035
Setpoints presetlistAbsolute (independent setpoint)
Comfort setpoint heatingunsignedInt 7…4021
Frost protection setpoint heatingunsignedInt 7…407
Heat protection setpoint coolingunsignedInt 7…4035
Comfort setpointunsignedInt 7…4021
Maximum setpointunsignedInt 1…203
Minimum setpointunsignedInt 1…203
Number of scenes usedunsignedInt 0…648
Scene 1unsignedInt 0…11
Scene 2unsignedInt 0…11
Scene 3unsignedInt 0…11
Scene 4unsignedInt 0…11
Scene 5unsignedInt 0…11
Scene 6unsignedInt 0…11
Scene 7unsignedInt 0…11
Scene 8unsignedInt 0…11
Scene 9unsignedInt 0…11
Scene 10unsignedInt 0…11
Scene 11unsignedInt 0…11
Scene 12unsignedInt 0…11
Scene 13unsignedInt 0…11
Scene 14unsignedInt 0…11
Scene 15unsignedInt 0…11
Scene 16unsignedInt 0…11
Scene 17unsignedInt 0…11
Scene 18unsignedInt 0…11
Scene 19unsignedInt 0…11
Scene 20unsignedInt 0…11
Scene 21unsignedInt 0…11
Scene 22unsignedInt 0…11
Scene 23unsignedInt 0…11
Scene 24unsignedInt 0…11
Scene 25unsignedInt 0…11
Scene 26unsignedInt 0…11
Scene 27unsignedInt 0…11
Scene 28unsignedInt 0…11
Scene 29unsignedInt 0…11
Scene 30unsignedInt 0…11
Scene 31unsignedInt 0…11
Scene 32unsignedInt 0…11
Scene 33unsignedInt 0…11
Scene 34unsignedInt 0…11
Scene 35unsignedInt 0…11
Scene 36unsignedInt 0…11
Scene 37unsignedInt 0…11
Scene 38unsignedInt 0…11
Scene 39unsignedInt 0…11
Scene 40unsignedInt 0…11
Scene 41unsignedInt 0…11
Scene 42unsignedInt 0…11
Scene 43unsignedInt 0…11
Scene 44unsignedInt 0…11
Scene 45unsignedInt 0…11
Scene 46unsignedInt 0…11
Scene 47unsignedInt 0…11
Scene 48unsignedInt 0…11
Scene 49unsignedInt 0…11
Scene 50unsignedInt 0…11
Scene 51unsignedInt 0…11
Scene 52unsignedInt 0…11
Scene 53unsignedInt 0…11
Scene 54unsignedInt 0…11
Scene 55unsignedInt 0…11
Scene 56unsignedInt 0…11
Scene 57unsignedInt 0…11
Scene 58unsignedInt 0…11
Scene 59unsignedInt 0…11
Scene 60unsignedInt 0…11
Scene 61unsignedInt 0…11
Scene 62unsignedInt 0…11
Scene 63unsignedInt 0…11
Scene 64unsignedInt 0…11
Scene 1 setpointlistComfort
Scene 2 setpointlistComfort
Scene 3 setpointlistComfort
Scene 4 setpointlistComfort
Scene 5 setpointlistComfort
Scene 6 setpointlistComfort
Scene 7 setpointlistComfort
Scene 8 setpointlistComfort
Scene 9 setpointlistComfort
Scene 10 setpointlistComfort
Scene 11 setpointlistComfort
Scene 12 setpointlistComfort
Scene 13 setpointlistComfort
Scene 14 setpointlistComfort
Scene 15 setpointlistComfort
Scene 16 setpointlistComfort
Scene 17 setpointlistComfort
Scene 18 setpointlistComfort
Scene 19 setpointlistComfort
Scene 20 setpointlistComfort
Scene 21 setpointlistComfort
Scene 22 setpointlistComfort
Scene 23 setpointlistComfort
Scene 24 setpointlistComfort
Scene 25 setpointlistComfort
Scene 26 setpointlistComfort
Scene 27 setpointlistComfort
Scene 28 setpointlistComfort
Scene 29 setpointlistComfort
Scene 30 setpointlistComfort
Scene 31 setpointlistComfort
Scene 32 setpointlistComfort
Scene 33 setpointlistComfort
Scene 34 setpointlistComfort
Scene 35 setpointlistComfort
Scene 36 setpointlistComfort
Scene 37 setpointlistComfort
Scene 38 setpointlistComfort
Scene 39 setpointlistComfort
Scene 40 setpointlistComfort
Scene 41 setpointlistComfort
Scene 42 setpointlistComfort
Scene 43 setpointlistComfort
Scene 44 setpointlistComfort
Scene 45 setpointlistComfort
Scene 46 setpointlistComfort
Scene 47 setpointlistComfort
Scene 48 setpointlistComfort
Scene 49 setpointlistComfort
Scene 50 setpointlistComfort
Scene 51 setpointlistComfort
Scene 52 setpointlistComfort
Scene 53 setpointlistComfort
Scene 54 setpointlistComfort
Scene 55 setpointlistComfort
Scene 56 setpointlistComfort
Scene 57 setpointlistComfort
Scene 58 setpointlistComfort
Scene 59 setpointlistComfort
Scene 60 setpointlistComfort
Scene 61 setpointlistComfort
Scene 62 setpointlistComfort
Scene 63 setpointlistComfort
Scene 64 setpointlistComfort
TimerunsignedInt 0…10
PriorityunsignedInt 0…10
Automatic controlunsignedInt 0…10
Automatic control deactivationunsignedInt 0…10
SceneunsignedInt 0…10
Timer operationlistComfort
Timer durationtime14400
Status after prioritylistTheoretical status without priority
Emergency powerunsignedInt 0…25576
Emergency powerunsignedInt 0…255178
Valve protection durationtime10
Standby setpoint heatingunsignedInt 7…4019
Standby offsetunsignedInt 1…202
Night setpoint coolingunsignedInt 7…4026
Night increaseunsignedInt 0…400
Night setpoint heatingunsignedInt 7…4016
Night offsetunsignedInt 0…405
Standby setpoint coolingunsignedInt 7…4023
Standby increaseunsignedInt 0…400
Comfort setpoint coolingunsignedInt 700…40002100
Difference between heating and coolingunsignedInt 0…400
Lock-up valueunsignedInt 0…255255
Emergency command valueunsignedInt 0…10030
Application software versiontext1.1.9
Version of translation filelist11
Heating enable polarityunsignedInt 0…2550
Floor temperature detectionlistNo
Minimum room temperatureunsignedInt 0…4000700
Maximum room temperatureunsignedInt 0…40003500
Maximum floor temperatureunsignedInt 2400…46002800
Maximum setpointunsignedInt 100…2000300
Minimum setpointunsignedInt 100…2000300
Comfort setpoint heatingunsignedInt 700…40002100
Basic comfort setpoint (°C)unsignedInt 700…40002100
Frost protection setpoint heatingunsignedInt 700…4000700
Setpoint frost protectionunsignedInt 700…4000700
Heat protection setpoint coolingunsignedInt 700…40003500
Setpoint heat protectionunsignedInt 700…40003500
CH8_SetpointsHeatingOffsetStandbyunsignedInt 100…2000200
CH8_SetpointsHeatingStandbyunsignedInt 700…40001900
CH8_SetpointsHeatingOffsetNightunsignedInt 100…2000500
CH8_SetpointsHeatingNightunsignedInt 700…40001600
Comfort setpoint coolingunsignedInt 700…40002300
CH8_SetpointsDeadZoneunsignedInt 0…40000
Night setpoint coolingunsignedInt 700…40002600
CH8_SetpointsCoolingOffsetNightunsignedInt 0…40000
Dead zone between heating and coolingunsignedInt 0…40000
Comfort setpoint coolingunsignedInt 7…4021
Priority between lock-up 1 and lock-up 2unsignedInt 0…2550
Lock-up valueunsignedInt 0…100100
Command value when priority activeunsignedInt 0…10030
Command value when emergency activeunsignedInt 0…10030
Command value when priority active in summerunsignedInt 0…25576
Valve protection minimum commande valueunsignedInt 0…10080
Default valve statuslistNormally closed
Cycle time for continous control with PWMtime900
Limiting value min. command valueunsignedInt 0…255204
Command value if active forced position summerunsignedInt 0…25576
Night offsetunsignedInt 1…205
Standby increaseunsignedInt 1…201
CH9_SetpointsHeatingOffsetStandbyunsignedInt 100…2000200
CH9_SetpointsHeatingOffsetNightunsignedInt 100…2000500
CH9_SetpointsDeadZoneunsignedInt 0…40000
CH9_SetpointsCoolingOffsetNightunsignedInt 0…40000
CH9_SetpointsHeatingStandbyunsignedInt 700…40001900
CH9_SetpointsHeatingNightunsignedInt 700…40001600
CH10_SetpointsHeatingOffsetStandbyunsignedInt 100…2000200
CH10_SetpointsHeatingOffsetNightunsignedInt 100…2000500
CH10_SetpointsDeadZoneunsignedInt 0…40000
CH10_SetpointsCoolingOffsetNightunsignedInt 0…40000
CH10_SetpointsHeatingStandbyunsignedInt 700…40001900
CH10_SetpointsHeatingNightunsignedInt 700…40001600
CH11_SetpointsHeatingOffsetStandbyunsignedInt 100…2000200
CH11_SetpointsHeatingOffsetNightunsignedInt 100…2000500
CH11_SetpointsDeadZoneunsignedInt 0…40000
CH11_SetpointsCoolingOffsetNightunsignedInt 0…40000
CH11_SetpointsHeatingStandbyunsignedInt 700…40001900
CH11_SetpointsHeatingNightunsignedInt 700…40001600
CH12_SetpointsHeatingOffsetStandbyunsignedInt 100…2000200
CH12_SetpointsHeatingOffsetNightunsignedInt 100…2000500
CH12_SetpointsDeadZoneunsignedInt 0…40000
CH12_SetpointsCoolingOffsetNightunsignedInt 0…40000
CH12_SetpointsHeatingStandbyunsignedInt 700…40001900
CH12_SetpointsHeatingNightunsignedInt 700…40001600
CH13_SetpointsHeatingOffsetStandbyunsignedInt 100…2000200
CH13_SetpointsHeatingOffsetNightunsignedInt 100…2000500
CH13_SetpointsDeadZoneunsignedInt 0…40000
CH13_SetpointsCoolingOffsetNightunsignedInt 0…40000
CH13_SetpointsHeatingStandbyunsignedInt 700…40001900
CH13_SetpointsHeatingNightunsignedInt 700…40001600
CH14_SetpointsHeatingOffsetStandbyunsignedInt 100…2000200
CH14_SetpointsHeatingOffsetNightunsignedInt 100…2000500
CH14_SetpointsDeadZoneunsignedInt 0…40000
CH14_SetpointsCoolingOffsetNightunsignedInt 0…40000
CH14_SetpointsHeatingStandbyunsignedInt 700…40001900
CH14_SetpointsHeatingNightunsignedInt 700…40001600
CH15_SetpointsHeatingOffsetStandbyunsignedInt 100…2000200
CH15_SetpointsHeatingOffsetNightunsignedInt 100…2000500
CH15_SetpointsDeadZoneunsignedInt 0…40000
CH15_SetpointsCoolingOffsetNightunsignedInt 0…40000
CH15_SetpointsHeatingStandbyunsignedInt 700…40001900
CH15_SetpointsHeatingNightunsignedInt 700…40001600
CH16_SetpointsHeatingOffsetStandbyunsignedInt 100…2000200
CH16_SetpointsHeatingOffsetNightunsignedInt 100…2000500
CH16_SetpointsDeadZoneunsignedInt 0…40000
CH16_SetpointsCoolingOffsetNightunsignedInt 0…40000
CH16_SetpointsHeatingStandbyunsignedInt 700…40001900
CH16_SetpointsHeatingNightunsignedInt 700…40001600
CH17_SetpointsHeatingOffsetStandbyunsignedInt 100…2000200
CH17_SetpointsHeatingOffsetNightunsignedInt 100…2000500
CH17_SetpointsDeadZoneunsignedInt 0…40000
CH17_SetpointsCoolingOffsetNightunsignedInt 0…40000
CH17_SetpointsHeatingStandbyunsignedInt 700…40001900
CH17_SetpointsHeatingNightunsignedInt 700…40001600
CH18_SetpointsHeatingOffsetStandbyunsignedInt 100…2000200
CH18_SetpointsHeatingOffsetNightunsignedInt 100…2000500
CH18_SetpointsDeadZoneunsignedInt 0…40000
CH18_SetpointsCoolingOffsetNightunsignedInt 0…40000
CH18_SetpointsHeatingStandbyunsignedInt 700…40001900
CH18_SetpointsHeatingNightunsignedInt 700…40001600
Priority between lock-up 1 and lock-up 2listLock-up 1 > Lock-up 2
Emergency command valueunsignedInt 0…10070
Command value when emergency active in summerunsignedInt 0…25576
Cmd value if active emergency operation summerunsignedInt 0…25576
Monitoring timetime60
Heating enable polarityunsignedInt 0…655350
Heating enable polaritytime600
Heating enable polaritylistOn status change and periodically
Status indication priority object polaritylist1 = Priority active, 0 = Priority not active
Priority object polaritylist1 = Priority active, 0 = Priority not active
CH1_CommandLimitingValuelistNot active
Behaviour after service modelistTheoretical status without service mode
Output accounted for service modelistYes
Output accounted for manual modelistYes
Object valve protection start/stop polaritylist1 = Start, 0 = Stop
Smart valve protectionlistYes
Setpoint selection during prioritylistComfort
Polaritylist0 = Not forced, 1 = Forced
Polarity of priority objectlist0 = deactivated, 1 = activated
CH23_Output1RegulatorslistYes
Restore ETS-params settingsunsignedInt 0…10
Heat requirement activation delaytime300
Heat requirement deactivation delaytime0
Outputs C1/C3/C5listOutput 1 < Output 3 < Output 5
Outputs C2/C4/C6listOutput 2 < Output 4 < Output 6
Setpoint objectslistCombined

Version history

ApplicationApp noFingerprintFirst seenSizeFile
STXM646R 1.2 latest$E0D335BF2026-11-25798 KBDownload
STXM646R 1.1$E0D3777C2026-11-25798 KBDownload
STXM646R 1.0$E0D325CD2026-11-25762 KBDownload

About this file

This is the official ETS product database for the Hager Electro Heating actuator 6 channels KNX, with regulation, 24/230V (TXM646R), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.