Heating actuator 6 channels KNX 24/230V TYMS646T
Hager Electro · Order number TYMS646T · Heating, Air Conditioning › Thermostat
Download .knxprod STYMS646T 1.3 · 358 KB
Product
| Manufacturer | Hager Electro |
|---|---|
| Product name | Heating actuator 6 channels KNX 24/230V |
| Order number | TYMS646T |
| Hardware | TYM646T |
| Medium | Twisted Pair |
| Bus current (mA) | 24 |
| Rail mounted | Yes |
| Registration | Registered · 2023-04-03 |
| Languages | fr-FR, de-DE, es-ES, it-IT, nl-NL, pt-PT, nb-NO, sv-SE |
| Catalog entry | M-0009_H-9.20.2F.2F.20TYMS646T-17_HP-E801-13-F381_CI-TYMS646T-1 |
| Fingerprint | F381 |
| SHA-256 | 33b4b4ebc7a27b323bd9a9cd703bda310890ad1ab7a1cb9e8191cc5c23d0e6b7 |
| First seen | 2026-11-25 |
| Markets | 69 markets |
Application program: STYMS646T 1.3
| Application number | $E801 |
|---|---|
| Version | 1.3 |
| Mask version | MV-07B0 (System B) |
| KNX Data Secure | Yes |
| Minimum ETS version | 5.0 |
| Parameters | 979 |
| Group objects | 203 |
Group objects (203)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 1 | {{0}} | ON/OFF | 1 Bit | 1.1 switch | CWTU |
| 2 | {{0}} | Valve position in % | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 3 | {{0}} | Status indication ON/OFF | 1 Bit | 1.1 switch | CRT |
| 4 | {{0}} | Status valve position in % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 5 | {{0}} | Command value monitoring failure | 1 Bit | 1.5 alarm | CRT |
| 6 | {{0}} | Short circuit/Overload status indication | 1 Bit | 1.5 alarm | CRT |
| 7 | {{0}} | Priority | 2 Bit | 2.2 boolean control | CWTU |
| 8 | {{0}} | Priority (1 bit) | 1 Bit | 1.3 enable | CWTU |
| 9 | {{0}} | Status indication priority | 1 Bit | 1.3 enable | CRT |
| 10 | {{0}} | Heating/Cooling - changeover | 1 Bit | 1.100 cooling/heating | CWTU |
| 11 | {{0}} | Command value limitation activation | 1 Bit | 1.3 enable | CWTU |
| 12 | {{0}} | Hours counter value (h) | 2 Bytes | 7.7 time (h) | CRT |
| 13 | {{0}} | Hours counter value (s) | 4 Bytes | 13.100 time lag (s) | CRT |
| 14 | {{0}} | Reset hours counter value | 1 Bit | 1.15 reset | CWTU |
| 15 | {{0}} | Hours counter setpoint reached | 1 Bit | 1.11 state | CRT |
| 16 | {{0}} | Hours counter setpoint (h) | 2 Bytes | 7.7 time (h) | CWTU |
| 17 | {{0}} | Hours counter setpoint (s) | 4 Bytes | 13.100 time lag (s) | CWTU |
| 18 | {{0}} | Valve protection date | 3 Bytes | 11.1 date | CWTU |
| 19 | {{0}} | Valve protection time | 3 Bytes | 10.1 time of day | CWTU |
| 20 | {{0}} | Valve protection date and time | 8 Bytes | 19.1 date time | CWTU |
| 21 | {{0}} | Valve protection duration | 2 Bytes | 7.6 time (min) | CWTU |
| 22 | {{0}} | Valve protection periodicity | 2 Bytes | 7.7 time (h) | CWTU |
| 23 | {{0}} | Valve protection start/stop | 1 Bit | 1.10 start/stop | CWTU |
| 24 | {{0}} | Lock-up 1 | 1 Bit | 1.3 enable | CWTU |
| 25 | {{0}} | Lock-up 2 | 1 Bit | 1.3 enable | CWTU |
| 26 | {{0}} | Status indication lock-up | 1 Bit | 1.3 enable | CRT |
| 27 | {{0}} | Room temperature failure | 1 Bit | 1.5 alarm | CWTU |
| 28 | {{0}} | ON/OFF | 1 Bit | 1.1 switch | CWTU |
| 29 | {{0}} | Valve position in % | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 30 | {{0}} | Status indication ON/OFF | 1 Bit | 1.1 switch | CRT |
| 31 | {{0}} | Status valve position in % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 32 | {{0}} | Command value monitoring failure | 1 Bit | 1.5 alarm | CRT |
| 33 | {{0}} | Short circuit/Overload status indication | 1 Bit | 1.5 alarm | CRT |
| 34 | {{0}} | Priority | 2 Bit | 2.2 boolean control | CWTU |
| 35 | {{0}} | Priority (1 bit) | 1 Bit | 1.3 enable | CWTU |
| 36 | {{0}} | Status indication priority | 1 Bit | 1.3 enable | CRT |
| 37 | {{0}} | Heating/Cooling - changeover | 1 Bit | 1.100 cooling/heating | CWTU |
| 38 | {{0}} | Command value limitation activation | 1 Bit | 1.3 enable | CWTU |
| 39 | {{0}} | Hours counter value (h) | 2 Bytes | 7.7 time (h) | CRT |
| 40 | {{0}} | Hours counter value (s) | 4 Bytes | 13.100 time lag (s) | CRT |
| 41 | {{0}} | Reset hours counter value | 1 Bit | 1.15 reset | CWTU |
| 42 | {{0}} | Hours counter setpoint reached | 1 Bit | 1.11 state | CRT |
| 43 | {{0}} | Hours counter setpoint (h) | 2 Bytes | 7.7 time (h) | CWTU |
| 44 | {{0}} | Hours counter setpoint (s) | 4 Bytes | 13.100 time lag (s) | CWTU |
| 45 | {{0}} | Valve protection date | 3 Bytes | 11.1 date | CWTU |
| 46 | {{0}} | Valve protection time | 3 Bytes | 10.1 time of day | CWTU |
| 47 | {{0}} | Valve protection date and time | 8 Bytes | 19.1 date time | CWTU |
| 48 | {{0}} | Valve protection duration | 2 Bytes | 7.6 time (min) | CWTU |
| 49 | {{0}} | Valve protection periodicity | 2 Bytes | 7.7 time (h) | CWTU |
| 50 | {{0}} | Valve protection start/stop | 1 Bit | 1.10 start/stop | CWTU |
| 51 | {{0}} | Lock-up 1 | 1 Bit | 1.3 enable | CWTU |
| 52 | {{0}} | Lock-up 2 | 1 Bit | 1.3 enable | CWTU |
| 53 | {{0}} | Status indication lock-up | 1 Bit | 1.3 enable | CRT |
| 54 | {{0}} | Room temperature failure | 1 Bit | 1.5 alarm | CWTU |
| 55 | {{0}} | ON/OFF | 1 Bit | 1.1 switch | CWTU |
| 56 | {{0}} | Valve position in % | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 57 | {{0}} | Status indication ON/OFF | 1 Bit | 1.1 switch | CRT |
| 58 | {{0}} | Status valve position in % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 59 | {{0}} | Command value monitoring failure | 1 Bit | 1.5 alarm | CRT |
| 60 | {{0}} | Short circuit/Overload status indication | 1 Bit | 1.5 alarm | CRT |
| 61 | {{0}} | Priority | 2 Bit | 2.2 boolean control | CWTU |
| 62 | {{0}} | Priority (1 bit) | 1 Bit | 1.3 enable | CWTU |
| 63 | {{0}} | Status indication priority | 1 Bit | 1.3 enable | CRT |
| 64 | {{0}} | Heating/Cooling - changeover | 1 Bit | 1.100 cooling/heating | CWTU |
| 65 | {{0}} | Command value limitation activation | 1 Bit | 1.3 enable | CWTU |
| 66 | {{0}} | Hours counter value (h) | 2 Bytes | 7.7 time (h) | CRT |
| 67 | {{0}} | Hours counter value (s) | 4 Bytes | 13.100 time lag (s) | CRT |
| 68 | {{0}} | Reset hours counter value | 1 Bit | 1.15 reset | CWTU |
| 69 | {{0}} | Hours counter setpoint reached | 1 Bit | 1.11 state | CRT |
| 70 | {{0}} | Hours counter setpoint (h) | 2 Bytes | 7.7 time (h) | CWTU |
| 71 | {{0}} | Hours counter setpoint (s) | 4 Bytes | 13.100 time lag (s) | CWTU |
| 72 | {{0}} | Valve protection date | 3 Bytes | 11.1 date | CWTU |
| 73 | {{0}} | Valve protection time | 3 Bytes | 10.1 time of day | CWTU |
| 74 | {{0}} | Valve protection date and time | 8 Bytes | 19.1 date time | CWTU |
| 75 | {{0}} | Valve protection duration | 2 Bytes | 7.6 time (min) | CWTU |
| 76 | {{0}} | Valve protection periodicity | 2 Bytes | 7.7 time (h) | CWTU |
| 77 | {{0}} | Valve protection start/stop | 1 Bit | 1.10 start/stop | CWTU |
| 78 | {{0}} | Lock-up 1 | 1 Bit | 1.3 enable | CWTU |
| 79 | {{0}} | Lock-up 2 | 1 Bit | 1.3 enable | CWTU |
| 80 | {{0}} | Status indication lock-up | 1 Bit | 1.3 enable | CRT |
| 81 | {{0}} | Room temperature failure | 1 Bit | 1.5 alarm | CWTU |
| 82 | {{0}} | ON/OFF | 1 Bit | 1.1 switch | CWTU |
| 83 | {{0}} | Valve position in % | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 84 | {{0}} | Status indication ON/OFF | 1 Bit | 1.1 switch | CRT |
| 85 | {{0}} | Status valve position in % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 86 | {{0}} | Command value monitoring failure | 1 Bit | 1.5 alarm | CRT |
| 87 | {{0}} | Short circuit/Overload status indication | 1 Bit | 1.5 alarm | CRT |
| 88 | {{0}} | Priority | 2 Bit | 2.2 boolean control | CWTU |
| 89 | {{0}} | Priority (1 bit) | 1 Bit | 1.3 enable | CWTU |
| 90 | {{0}} | Status indication priority | 1 Bit | 1.3 enable | CRT |
| 91 | {{0}} | Heating/Cooling - changeover | 1 Bit | 1.100 cooling/heating | CWTU |
| 92 | {{0}} | Command value limitation activation | 1 Bit | 1.3 enable | CWTU |
| 93 | {{0}} | Hours counter value (h) | 2 Bytes | 7.7 time (h) | CRT |
| 94 | {{0}} | Hours counter value (s) | 4 Bytes | 13.100 time lag (s) | CRT |
| 95 | {{0}} | Reset hours counter value | 1 Bit | 1.15 reset | CWTU |
| 96 | {{0}} | Hours counter setpoint reached | 1 Bit | 1.11 state | CRT |
| 97 | {{0}} | Hours counter setpoint (h) | 2 Bytes | 7.7 time (h) | CWTU |
| 98 | {{0}} | Hours counter setpoint (s) | 4 Bytes | 13.100 time lag (s) | CWTU |
| 99 | {{0}} | Valve protection date | 3 Bytes | 11.1 date | CWTU |
| 100 | {{0}} | Valve protection time | 3 Bytes | 10.1 time of day | CWTU |
| 101 | {{0}} | Valve protection date and time | 8 Bytes | 19.1 date time | CWTU |
| 102 | {{0}} | Valve protection duration | 2 Bytes | 7.6 time (min) | CWTU |
| 103 | {{0}} | Valve protection periodicity | 2 Bytes | 7.7 time (h) | CWTU |
| 104 | {{0}} | Valve protection start/stop | 1 Bit | 1.10 start/stop | CWTU |
| 105 | {{0}} | Lock-up 1 | 1 Bit | 1.3 enable | CWTU |
| 106 | {{0}} | Lock-up 2 | 1 Bit | 1.3 enable | CWTU |
| 107 | {{0}} | Status indication lock-up | 1 Bit | 1.3 enable | CRT |
| 108 | {{0}} | Room temperature failure | 1 Bit | 1.5 alarm | CWTU |
| 109 | {{0}} | ON/OFF | 1 Bit | 1.1 switch | CWTU |
| 110 | {{0}} | Valve position in % | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 111 | {{0}} | Status indication ON/OFF | 1 Bit | 1.1 switch | CRT |
| 112 | {{0}} | Status valve position in % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 113 | {{0}} | Command value monitoring failure | 1 Bit | 1.5 alarm | CRT |
| 114 | {{0}} | Short circuit/Overload status indication | 1 Bit | 1.5 alarm | CRT |
| 115 | {{0}} | Priority | 2 Bit | 2.2 boolean control | CWTU |
| 116 | {{0}} | Priority (1 bit) | 1 Bit | 1.3 enable | CWTU |
| 117 | {{0}} | Status indication priority | 1 Bit | 1.3 enable | CRT |
| 118 | {{0}} | Heating/Cooling - changeover | 1 Bit | 1.100 cooling/heating | CWTU |
| 119 | {{0}} | Command value limitation activation | 1 Bit | 1.3 enable | CWTU |
| 120 | {{0}} | Hours counter value (h) | 2 Bytes | 7.7 time (h) | CRT |
| 121 | {{0}} | Hours counter value (s) | 4 Bytes | 13.100 time lag (s) | CRT |
| 122 | {{0}} | Reset hours counter value | 1 Bit | 1.15 reset | CWTU |
| 123 | {{0}} | Hours counter setpoint reached | 1 Bit | 1.11 state | CRT |
| 124 | {{0}} | Hours counter setpoint (h) | 2 Bytes | 7.7 time (h) | CWTU |
| 125 | {{0}} | Hours counter setpoint (s) | 4 Bytes | 13.100 time lag (s) | CWTU |
| 126 | {{0}} | Valve protection date | 3 Bytes | 11.1 date | CWTU |
| 127 | {{0}} | Valve protection time | 3 Bytes | 10.1 time of day | CWTU |
| 128 | {{0}} | Valve protection date and time | 8 Bytes | 19.1 date time | CWTU |
| 129 | {{0}} | Valve protection duration | 2 Bytes | 7.6 time (min) | CWTU |
| 130 | {{0}} | Valve protection periodicity | 2 Bytes | 7.7 time (h) | CWTU |
| 131 | {{0}} | Valve protection start/stop | 1 Bit | 1.10 start/stop | CWTU |
| 132 | {{0}} | Lock-up 1 | 1 Bit | 1.3 enable | CWTU |
| 133 | {{0}} | Lock-up 2 | 1 Bit | 1.3 enable | CWTU |
| 134 | {{0}} | Status indication lock-up | 1 Bit | 1.3 enable | CRT |
| 135 | {{0}} | Room temperature failure | 1 Bit | 1.5 alarm | CWTU |
| 136 | {{0}} | ON/OFF | 1 Bit | 1.1 switch | CWTU |
| 137 | {{0}} | Valve position in % | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 138 | {{0}} | Status indication ON/OFF | 1 Bit | 1.1 switch | CRT |
| 139 | {{0}} | Status valve position in % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 140 | {{0}} | Command value monitoring failure | 1 Bit | 1.5 alarm | CRT |
| 141 | {{0}} | Short circuit/Overload status indication | 1 Bit | 1.5 alarm | CRT |
| 142 | {{0}} | Priority | 2 Bit | 2.2 boolean control | CWTU |
| 143 | {{0}} | Priority (1 bit) | 1 Bit | 1.3 enable | CWTU |
| 144 | {{0}} | Status indication priority | 1 Bit | 1.3 enable | CRT |
| 145 | {{0}} | Heating/Cooling - changeover | 1 Bit | 1.100 cooling/heating | CWTU |
| 146 | {{0}} | Command value limitation activation | 1 Bit | 1.3 enable | CWTU |
| 147 | {{0}} | Hours counter value (h) | 2 Bytes | 7.7 time (h) | CRT |
| 148 | {{0}} | Hours counter value (s) | 4 Bytes | 13.100 time lag (s) | CRT |
| 149 | {{0}} | Reset hours counter value | 1 Bit | 1.15 reset | CWTU |
| 150 | {{0}} | Hours counter setpoint reached | 1 Bit | 1.11 state | CRT |
| 151 | {{0}} | Hours counter setpoint (h) | 2 Bytes | 7.7 time (h) | CWTU |
| 152 | {{0}} | Hours counter setpoint (s) | 4 Bytes | 13.100 time lag (s) | CWTU |
| 153 | {{0}} | Valve protection date | 3 Bytes | 11.1 date | CWTU |
| 154 | {{0}} | Valve protection time | 3 Bytes | 10.1 time of day | CWTU |
| 155 | {{0}} | Valve protection date and time | 8 Bytes | 19.1 date time | CWTU |
| 156 | {{0}} | Valve protection duration | 2 Bytes | 7.6 time (min) | CWTU |
| 157 | {{0}} | Valve protection periodicity | 2 Bytes | 7.7 time (h) | CWTU |
| 158 | {{0}} | Valve protection start/stop | 1 Bit | 1.10 start/stop | CWTU |
| 159 | {{0}} | Lock-up 1 | 1 Bit | 1.3 enable | CWTU |
| 160 | {{0}} | Lock-up 2 | 1 Bit | 1.3 enable | CWTU |
| 161 | {{0}} | Status indication lock-up | 1 Bit | 1.3 enable | CRT |
| 162 | {{0}} | Room temperature failure | 1 Bit | 1.5 alarm | CWTU |
| 163 | General | Summer/winter mode changeover | 1 Bit | 1.1 switch | CWTU |
| 164 | General | Summer/winter changeover date | 3 Bytes | 11.1 date | CWTU |
| 165 | General | Winter/summer changeover date | 3 Bytes | 11.1 date | CWTU |
| 166 | General | Valves operating voltage failure | 1 Bit | 1.5 alarm | CRT |
| 167 | General | Reset short circuit/overload | 1 Bit | 1.2 boolean | CWTU |
| 168 | General | Heat requirement | 1 Bit | 1.2 boolean | CRT |
| 169 | General | External heat requirement | 1 Bit | 1.2 boolean | CWTU |
| 170 | General | Largest command value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 171 | General | External largest command value | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 172 | General | Service mode | 2 Bit | 2.1 switch control | CWTU |
| 173 | General | Status indication service mode | 1 Bit | 1.2 boolean | CRT |
| 174 | General | Pump ON/OFF | 1 Bit | 1.1 switch | CRT |
| 175 | General | External pump control | 1 Bit | 1.1 switch | CWTU |
| 176 | General | Pump protection date | 3 Bytes | 11.1 date | CWTU |
| 177 | General | Pump protection time | 3 Bytes | 10.1 time of day | CWTU |
| 178 | General | Pump protection date and time | 8 Bytes | 19.1 date time | CWTU |
| 179 | General | Pump protection duration | 2 Bytes | 7.6 time (min) | CWTU |
| 180 | General | Pump protection periodicity | 2 Bytes | 7.7 time (h) | CWTU |
| 181 | General | Pump protection start/stop | 1 Bit | 1.10 start/stop | CWTU |
| 182 | General | Heating activation | 1 Bit | 1.1 switch | CWTU |
| 183 | Logic block 1 | Authorization | 1 Bit | 1.3 enable | CWTU |
| 184 | Logic block 1 | Input 1 | 1 Bit | 1.2 boolean | CWTU |
| 185 | Logic block 1 | Input 2 | 1 Bit | 1.2 boolean | CWTU |
| 186 | Logic block 1 | Input 3 | 1 Bit | 1.2 boolean | CWTU |
| 187 | Logic block 1 | Input 4 | 1 Bit | 1.2 boolean | CWTU |
| 188 | Logic block 1 | Logic result | 1 Bit | 1.2 boolean | CRT |
| 189 | Logic block 2 | Authorization | 1 Bit | 1.3 enable | CWTU |
| 190 | Logic block 2 | Input 1 | 1 Bit | 1.2 boolean | CWTU |
| 191 | Logic block 2 | Input 2 | 1 Bit | 1.2 boolean | CWTU |
| 192 | Logic block 2 | Input 3 | 1 Bit | 1.2 boolean | CWTU |
| 193 | Logic block 2 | Input 4 | 1 Bit | 1.2 boolean | CWTU |
| 194 | Logic block 2 | Logic result | 1 Bit | 1.2 boolean | CRT |
| 195 | General | Date | 3 Bytes | 11.1 date | CWTU |
| 196 | General | Time | 3 Bytes | 10.1 time of day | CWTU |
| 197 | General | Date and time | 8 Bytes | 19.1 date time | CWTU |
| 198 | General | Date and time request | 1 Bit | 1.17 trigger | CRT |
| 199 | General | Deactivation of manual mode | 1 Bit | 1.3 enable | CWTU |
| 200 | General | Status indication manual mode | 1 Bit | 1.3 enable | CRT |
| 201 | General | Restore ETS-params settings | 1 Bit | 1.1 switch | CWTU |
| 202 | General | Device LED switch off | 1 Bit | 1.1 switch | CWTU |
| 203 | General | Diagnosis | 6 Bytes | CRT |
Parameters (197)
| Parameter | Type | Default |
|---|---|---|
| Authorization object logic block | list | Not active |
| Value at initialization | list | Value before initialization |
| Polarity | list | 0 = Locked-up , 1 = Authorized |
| Logic function type | list | OR |
| Logic result after authorisation | list | Immediate emission when authorization |
| Emission of logic result | list | By logic result value change |
| Number of logic inputs | list | 1 |
| Value at initialization of logic input 1 | list | Value before initialization |
| Value at initialization of logic input 2 | list | Value before initialization |
| Value at initialization of logic input 3 | list | Value before initialization |
| Value at initialization of logic input 4 | list | Value before initialization |
| Inverting value of logic input 1 | list | Maintain status |
| Inverting value of logic input 2 | list | Maintain status |
| Inverting value of logic input 3 | list | Maintain status |
| Inverting value of logic input 4 | list | Maintain status |
| Logic result acts on thermostats | list | No |
| Manual mode | list | Active |
| Polarity | list | 0=Manual mode locked-up, 1=Manual mode authorized |
| Polarity | list | 0=Manual mode deactivated, 1=Manual mode activated |
| Polarity | list | Active |
| Duration of manual mode activation | time | 30 |
| Emission | list | On status change |
| Summer/winter changeover mode | list | By date |
| Polarity | list | 1 = Summer, 0 = Winter |
| Summer/winter mode after ETS download | list | No change |
| Behaviour after service mode | list | Theoretical status without service mode |
| Emission period | time | 1800 |
| Polarity | list | 0 = Always OFF, 1 = Status indication |
| Device LED switch off object | list | No |
| Status indication | list | Active |
| Service mode | list | No |
| Device diagnosis object | list | No |
| Logic block 1 | list | Not active |
| Logic block 2 | list | Not active |
| Summer/winter mode changeover | list | No |
| Outputs parameters settings | list | Individual configuration |
| Number of used outputs | list | 6 outputs |
| Output 1 name | text | Output 1 |
| Output 2 name | text | Output 2 |
| Output 3 name | text | Output 3 |
| Output 4 name | text | Output 4 |
| Output 5 name | text | Output 5 |
| Output 6 name | text | Output 6 |
| Default valve status | list | Normally closed |
| Status after bus power cut | list | Value as emergency |
| Behaviour after ETS download | list | Specific command value |
| Hours counter | list | Not active |
| Output accounted for pump control | list | Yes |
| Output accounted for heating requirement | list | Yes |
| Output accounted for largest command value | list | Yes |
| Output accounted for service mode | list | Yes |
| Output accounted for manual mode | list | Yes |
| Emission during manual mode | list | Not active |
| Hours counter direction | list | Increment |
| Hours counter setpoint | signedInt 0…2147483647 | 235926000 |
| Counter setpoint value modifiable through object | list | Not active |
| Hours counter objects unit | list | Seconds |
| Emission | list | Periodically |
| Periodical emission delay | time | 1800 |
| Value interval | unsignedInt 0…65535 | 1 |
| Emission | list | On status change and periodically |
| Valve protection | list | Active |
| Valve protection activation | list | Periodically |
| Polarity | list | 1 = Start, 0 = Stop |
| Smart valve protection | list | Yes |
| Limiting value min. command value | unsignedInt 0…255 | 204 |
| Periodicity | list | Every week |
| CH1_ValveRinsingDate | date | 2018-01-24 |
| Time | time | 0 |
| Lock-up duration | list | Permanently |
| Polarity of lock-up object 1 | list | 0 = Lock-up deactivated, 1 = Lock-up activated |
| Polarity of lock-up object 2 | list | 0 = Lock-up deactivated, 1 = Lock-up activated |
| Priority between lock-up 1 and lock-up 2 | unsignedInt 0…255 | 1 |
| Status if lock-up 1 | list | Maintain status |
| Status if lock-up 2 | list | Maintain status |
| Status after lock-up function 1 | list | Maintain status |
| Status after lock-up function 2 | list | Maintain status |
| Activation of lock-up status object | list | Not active |
| Polarity | list | 0 = Lock-up deactivated, 1 = Lock-up activated |
| Emission period | time | 600 |
| Cycle time for continous control with PWM | time | 900 |
| Same 2 | list | Not active |
| Command value format | list | Continous with PWM (1 byte) |
| Command value monitoring | list | Yes |
| Monitoring time | time | 60 |
| Command value limitation | list | Not used |
| Command value limitation at bus return | list | No |
| Command value limitation after ETS download | list | No |
| Minimum command value | unsignedInt 0…255 | 0 |
| Maximum command value | unsignedInt 0…255 | 255 |
| Cmd value if active emergency operation summer | unsignedInt 0…255 | 76 |
| Cmd value if active emergency operation winter | unsignedInt 0…255 | 178 |
| Command value if active forced position summer | unsignedInt 0…255 | 76 |
| Command value if active forced position winter | unsignedInt 0…255 | 178 |
| Priority object format | list | Not used |
| Polarity | list | 1 = Priority active, 0 = Priority not active |
| Short circuit/Overload status indication | list | No |
| Value interval | unsignedInt 0…65535 | 1800 |
| Lock-up value | unsignedInt 0…255 | 255 |
| Valve protection duration | time | 10 |
| Day | list | 13 |
| Hour | unsignedInt 0…23 | 0 |
| Min | unsignedInt 0…59 | 0 |
| Month | list | March |
| Year | unsignedInt 0…4095 | 1972 |
| Year-Month | unsignedInt 0…65535 | 10164 |
| Date and time request delay at initialization | unsignedInt 0…255 | 20 |
| Date and time objects | list | 1 object (8 bytes) |
| Activ. of restore ETS-parameters object | list | Not active |
| Lock-up duration | unsignedInt 0…4294967295 | 900000 |
| Value after ETS programming | unsignedInt 0…255 | 0 |
| Application software version | text | 1.3.2 |
| Version of translation file | list | 12 |
| Response to bus voltage failure | unsignedInt 0…255 | 0 |
| Regulation type | list | Heating |
| Polarity | list | 1 = Failure, 0 = No failure |
| Valves operating voltage failure object | list | No |
| Short circuit/overload reset object | list | No |
| Heat requirement | list | Yes |
| Polarity | list | 1 = Heat requirement, 0 = No heat requirement |
| External heat requirement | list | No |
| Threshold value for heat requirement sending | unsignedInt 0…100 | 1 |
| Hysteresis value for heat requirement sending | unsignedInt 1…20 | 1 |
| Heat requirement activation delay | time | 300 |
| Heat requirement deactivation delay | time | 0 |
| Largest command value | list | No |
| Value emission by variation of | unsignedInt 0…65535 | 7 |
| External largest command value | list | No |
| Pump control | list | No |
| Polarity | list | 1 = Pump ON, 0 = Pump OFF |
| External pump control | list | No |
| Threshold value for pump control sending | unsignedInt 0…100 | 1 |
| Pump activation delay | time | 300 |
| Pump deactivation delay | time | 0 |
| Pump protection | list | No |
| Pump protection activation | list | Periodically |
| Limiting value min. command value | unsignedInt 0…255 | 0 |
| Date of first activation (dd/mm/yyyy) | date | 1972-03-13 |
| Time of first activation | time | 0 |
| Pump protection duration | time | 5 |
| Minutes | unsignedInt 0…59 | 0 |
| Seconds | unsignedInt 0…255 | 0 |
| Summer/winter changeover date | list | October |
| Winter/summer changeover date | list | April |
| Sec | unsignedInt 0…59 | 0 |
| Priority between lock-up 1 and lock-up 2 | unsignedInt 0…255 | 0 |
| Limiting value of the command value for opening the valve | unsignedInt 0…255 | 25 |
| Hysteresis limiting value for closing the valve | unsignedInt 0…255 | 12 |
| Status indication priority object | list | Not active |
| Command value | unsignedInt 0…100 | 0 |
| Minimum command value | unsignedInt 0…100 | 0 |
| Lock-up value | unsignedInt 0…100 | 100 |
| Maximum command value | unsignedInt 0…100 | 100 |
| Threshold value for valve opening/closing | unsignedInt 0…100 | 10 |
| Hysteresis value for valve opening/closing | unsignedInt 0…100 | 5 |
| Command value when priority active in winter | unsignedInt 0…100 | 70 |
| Command value when priority active in summer | unsignedInt 0…100 | 30 |
| Command value when emergency active in summer | unsignedInt 0…100 | 30 |
| Command value when emergency active in winter | unsignedInt 0…100 | 70 |
| Command value when priority active | unsignedInt 0…100 | 30 |
| Command value when emergency active | unsignedInt 0…100 | 30 |
| Value emission by variation of | unsignedInt 0…100 | 80 |
| CH1_CommandLimitingValue | list | Not active |
| {{0}} | list | Theoretical status without service mode |
| Valve protection minimum commande value | unsignedInt 0…100 | 80 |
| Same 0 1 | list | Not active |
| Heating activation status | list | Active |
| Polarity | list | 1 = Heating activ., 0 = Heating deactiv. |
| Threshold | unsignedInt 0…255 | 2 |
| Hysteresis | unsignedInt 0…255 | 2 |
| Polarity | list | 1 = Service mode active, 0 = Service mode not active |
| Restore ETS-params settings | unsignedInt 0…1 | 0 |
| Outputs C1/C3 | list | Output 1 < Output 3 |
| Outputs C1/C3/C5 | list | Output 1 < Output 3 < Output 5 |
| Outputs C2/C4 | list | Output 2 < Output 4 |
| Outputs C2/C4/C6 | list | Output 2 < Output 4 < Output 6 |
| Priority between lock-up 1 and lock-up 2 | list | Lock-up 1 > Lock-up 2 |
| Threshold | unsignedInt 0…65535 | 7 |
| Valve protection minimum commande value (10-100%) | unsignedInt 0…65535 | 7 |
| Cov | unsignedInt 0…65535 | 1 |
| Objects emission delay at bus return | time | 25 |
| Hours counter setpoint | unsignedInt 0…1193046 | 65535 |
| Value emission by variation of | unsignedInt 0…100 | 3 |
| Duration | time | 15 |
| Output 1 controlled by | list | External thermostat |
| Output 2 controlled by | list | External thermostat |
| Output 3 controlled by | list | External thermostat |
| Output 4 controlled by | list | External thermostat |
| Output 5 controlled by | list | External thermostat |
| Output 6 controlled by | list | External thermostat |
| Lock-up | list | Not active |
| Number of lock-up objects | list | 1 |
| Object status indication manual mode | list | Not active |
| Object deactivation of manual mode | list | Not active |
| CH23_Dummy5 | unsignedInt 0…65535 | 1 |
| Heating activation object | list | Yes |
| Hardware Type | list | $00 09 E8 01 00 00 |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| STYMS646T 1.3 latest | $E801 | F381 | 2026-11-25 | 358 KB | Download |
About this file
This is the official ETS product database for the Hager Electro Heating actuator 6 channels KNX 24/230V (TYMS646T), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from Hager Electro
- 6-output module heating actuator TX206H
- Thermostat TX320
- Valve actuator TX501
- Valve actuator with temperature control TX502
- 6 sorties fil pilote maître TXA230A
- 6 sorties fil pilote esclave TXA230B
- Heating actuator 6 channels KNX, with regulation, 24/230V TXM646R
- Heating actuator 6 channels KNX 24/230V TXM646T
- Heating actuator 1 gang 230V AC flush mounted TYB641A
- Room programmer 6 zones TYD480
- Fan coil actuator 2 gang 10A TYF642F
- Heating actuator 6 gang triac 230V AC TYF646T