Ekinex S.p.A. EK-HB1-TP EK-HB1-TP - Fan-coil actuator/controller

EK-HB1-TP - Fan-coil actuator/controller EK-HB1-TP

Ekinex S.p.A. · Order number EK-HB1-TP · Heating, cooling and ventilation

EK-HB1-TP - Fan-coil actuator/controller

Download .knxprod APEKHB1TP 0.5 · 174 KB

Product

ManufacturerEkinex S.p.A.
Product nameEK-HB1-TP - Fan-coil actuator/controller
Order numberEK-HB1-TP
HardwareFan-coil actuator/controller
MediumTwisted Pair
Bus current (mA)10
Rail mountedYes
Width (mm)72
RegistrationCertified · 2017-06-26
Languagesen-US, de-DE, fr-FR, it-IT
Catalog entryM-00B6_H-000027-1_HP-4842-05-33D9_CI-EK.2DHB1.2DTP-1
Fingerprint33D9
SHA-2561b7702f2b700affc3922433021b425ffa053792f67a96f9574ea5b68e70f3408
First seen2026-11-25
Markets69 markets

Application program: APEKHB1TP 0.5

Application number$4842
Version0.5
Mask versionMV-0705 (7.5)
KNX Data SecureNo
Minimum ETS version5.0
Parameters356
Group objects139
Group objects (139)
NoNameFunctionSizeDPTFlags
0Fan continuous speed command1 Byte5.1 percentage (0..100%)CW
0First fan speed command1 Bit1.1 switchCW
0Fan continuous speed command counter1 Byte5.100 fan stage (0..255)CW
0Fan continuous speed manual command1 Byte5.100 fan stage (0..255)CW
1Second fan speed command1 Bit1.1 switchCW
1Fan continuous speed manual counter1 Byte5.100 fan stage (0..255)CW
2Third fan speed command1 Bit1.1 switchCW
3Heating valve command (on/off)1 Bit1.19 window/doorCW
3Heating valve command (PWM)1 Byte5.1 percentage (0..100%)CW
3Heating/cooling valve command (on/off)1 Bit1.1 switchCW
3Heating/cooling valve command (PWM)1 Byte5.1 percentage (0..100%)CW
4Cooling valve command (on/off)1 Bit1.1 switchCW
4Cooling valve command (PWM)1 Byte5.1 percentage (0..100%)CW
5Heating/cooling changeover command1 Bit1.100 cooling/heatingCW
7Actual fan speed %1 Byte5.1 percentage (0..100%)CRT
8Fan stopped1 Bit1.1 switchCRT
9First speed fan speed status1 Bit1.1 switchCRT
10Second speed fan speed status1 Bit1.1 switchCRT
11Third speed fan speed status1 Bit1.1 switchCRT
12Counter speed fan status1 Byte5.100 fan stage (0..255)CRT
13Heating/cooling valve status1 Bit1.19 window/doorCRT
13Heating valve status1 Bit1.1 switchCRT
14Cooling valve status1 Bit1.1 switchCRT
15Technical alarm1 Bit1.5 alarmCRT
16Communication alarm1 Bit1.5 alarmCRT
18Thermal generator locked1 Bit1.5 alarmCW
19Temperature control alarm1 Bit1.5 alarmCRT
20Antistratification temperature sensor (from input 1)2 Bytes9.1 temperature (°C)CRT
20Coil battery temperature sensor (from input 1)2 Bytes9.1 temperature (°C)CRT
20Room temperature sensor (from input 1)2 Bytes9.1 temperature (°C)CRT
20Outdoor temperature sensor (from input 1)2 Bytes9.1 temperature (°C)CRT
20Temperature value sensor (from input 1)2 Bytes9.1 temperature (°C)CRT
20Flow temperature sensor (from input 1)2 Bytes9.1 temperature (°C)CRT
21Temperature threshold 1 sensor 1 - Switch1 Bit1.1 switchCRT
22Temperature threshold 2 sensor 1 - Switch1 Bit1.1 switchCRT
23Antistratification temperature sensor (from input 2)2 Bytes9.1 temperature (°C)CRT
23Coil battery temperature sensor (from input 2)2 Bytes9.1 temperature (°C)CRT
23Room temperature sensor (from input 2)2 Bytes9.1 temperature (°C)CRT
23Outdoor temperature sensor (from input 2)2 Bytes9.1 temperature (°C)CRT
23Temperature value sensor (from input 2)2 Bytes9.1 temperature (°C)CRT
23Flow temperature sensor (from input 2)2 Bytes9.1 temperature (°C)CRT
24Temperature threshold 1 sensor 2 - Switch1 Bit1.1 switchCRT
25Temperature threshold 2 sensor 2 - Switch1 Bit1.1 switchCRT
29Window contact (from input 1)1 Bit1.19 window/doorCRT
29Drip tray contact (from input 1)1 Bit1.5 alarmCRT
29Generic contact (from input 1)1 Bit1.19 window/doorCRT
30Window contact (from input 2)1 Bit1.19 window/doorCRT
30Drip tray contact (from input 2)1 Bit1.5 alarmCRT
30Generic contact (from input 2)1 Bit1.19 window/doorCRT
32Room temperature from bus2 Bytes9.1 temperature (°C)CW
33Outdoor temperature (from bus)2 Bytes9.1 temperature (°C)CW
34Coil battery temperature sensor from bus2 Bytes9.1 temperature (°C)CW
35Antistratification temperature from bus2 Bytes9.1 temperature (°C)CW
36Water supply temperature from bus2 Bytes9.1 temperature (°C)CW
37Drip tray contact from bus1 Bit1.5 alarmCW
38Window contact 1 (from bus)1 Bit1.19 window/doorCW
39Window contact 2 (from bus)1 Bit1.19 window/doorCW
40Presence sensor 1 from bus1 Bit1.18 occupancyCW
41Presence sensor 2 from bus1 Bit1.18 occupancyCW
42Heating/cooling status out1 Bit1.100 cooling/heatingCRT
43Heating/cooling changeover command1 Bit1.100 cooling/heatingCW
44HVAC mode IN1 Byte20.102 HVAC modeCW
45HVAC manual mode1 Byte20.102 HVAC modeCW
46HVAC chrono mode active status1 Bit1.11 stateCRWTU
47HVAC mode OUT1 Byte20.102 HVAC modeCRT
48Actual setpoint2 Bytes9.1 temperature (°C)CRT
49Input setpoint2 Bytes9.1 temperature (°C)CW
50Comfort setpoint (heating)2 Bytes9.1 temperature (°C)CRWTU
51Comfort setpoint (cooling)2 Bytes9.1 temperature (°C)CRWTU
52Standby offset (heating)2 Bytes9.2 temperature difference (K)CRWTU
52Standby setpoint (heating)2 Bytes9.1 temperature (°C)CRWTU
53Standby offset (cooling)2 Bytes9.2 temperature difference (K)CRWTU
53Standby setpoint (cooling)2 Bytes9.1 temperature (°C)CRWTU
54Economy offset (heating)2 Bytes9.2 temperature difference (K)CRWTU
54Economy setpoint (heating)2 Bytes9.1 temperature (°C)CRWTU
55Economy offset (cooling)2 Bytes9.2 temperature difference (K)CRWTU
55Economy setpoint (cooling)2 Bytes9.1 temperature (°C)CRWTU
56Building protection (heating)2 Bytes9.1 temperature (°C)CRWTU
57Building protection (cooling)2 Bytes9.1 temperature (°C)CRWTU
58Manual/forced setpioint active status1 Bit1.11 stateCRWTU
59Manual setpoint2 Bytes9.1 temperature (°C)CRWTU
60Cooling compensation offset2 Bytes9.2 temperature difference (K)CRT
61Temperature controller output1 Byte5.1 percentage (0..100%)CRT
62Fan working time (hours)4 Bytes12.102 counter timehrs (h)CRT
63Fan working time (seconds)4 Bytes13.100 time lag (s)CRT
64Filter change warning1 Bit1.5 alarmCRWT
65Fan disable1 Bit1.3 enableCW
66Fan manual / auto status1 Bit1.11 stateCRWTU
67Heating/cooling valve disable from bus1 Bit1.3 enableCW
67Heating valve disable1 Bit1.3 enableCW
68Cooling valve disable1 Bit1.3 enableCW
71Controller output forced from bus1 Byte5.1 percentage (0..100%)CW
72Controller output in automatic/forced from bus mode1 Bit1.3 enableCW
73Drip tray status1 Bit1.5 alarmCRT
75Power off alarm1 Bit1.5 alarmCRT
79Output DO1 from bus1 Bit1.1 switchCW
81Output 0-10V from bus1 Byte5.1 percentage (0..100%)CW
82Fan speed limit enable1 Bit1.3 enableCW
83AlarmText14 Bytes16.0 Character String (ASCII)CRT
84Logic function 1 - Input 11 Bit1.1 switchCWTU
85Logic function 1 - Input 21 Bit1.1 switchCWTU
86Logic function 1 - Input 31 Bit1.1 switchCWTU
87Logic function 1 - Input 41 Bit1.1 switchCWTU
88Logic function 1 - Output1 Bit1.1 switchCRT
89Logic function 2 - Input 11 Bit1.1 switchCWTU
90Logic function 2 - Input 21 Bit1.1 switchCWTU
91Logic function 2 - Input 31 Bit1.1 switchCWTU
92Logic function 2 - Input 41 Bit1.1 switchCWTU
93Logic function 2 - Output1 Bit1.1 switchCRT
94Logic function 3 - Input 11 Bit1.1 switchCWTU
95Logic function 3 - Input 21 Bit1.1 switchCWTU
96Logic function 3 - Input 31 Bit1.1 switchCWTU
97Logic function 3 - Input 41 Bit1.1 switchCWTU
98Logic function 3 - Output1 Bit1.1 switchCRT
99Logic function 4 - Input 11 Bit1.1 switchCWTU
100Logic function 4 - Input 21 Bit1.1 switchCWTU
101Logic function 4 - Input 31 Bit1.1 switchCWTU
102Logic function 4 - Input 41 Bit1.1 switchCWTU
103Logic function 4 - Output1 Bit1.1 switchCRT
104Logic function 5 - Input 11 Bit1.1 switchCWTU
105Logic function 5 - Input 21 Bit1.1 switchCWTU
106Logic function 5 - Input 31 Bit1.1 switchCWTU
107Logic function 5 - Input 41 Bit1.1 switchCWTU
108Logic function 5 - Output1 Bit1.1 switchCRT
109Logic function 6 - Input 11 Bit1.1 switchCWTU
110Logic function 6 - Input 21 Bit1.1 switchCWTU
111Logic function 6 - Input 31 Bit1.1 switchCWTU
112Logic function 6 - Input 41 Bit1.1 switchCWTU
113Logic function 6 - Output1 Bit1.1 switchCRT
114Logic function 7 - Input 11 Bit1.1 switchCWTU
115Logic function 7 - Input 21 Bit1.1 switchCWTU
116Logic function 7 - Input 31 Bit1.1 switchCWTU
117Logic function 7 - Input 41 Bit1.1 switchCWTU
118Logic function 7 - Output1 Bit1.1 switchCRT
119Logic function 8 - Input 11 Bit1.1 switchCWTU
120Logic function 8 - Input 21 Bit1.1 switchCWTU
121Logic function 8 - Input 31 Bit1.1 switchCWTU
122Logic function 8 - Input 41 Bit1.1 switchCWTU
123Logic function 8 - Output1 Bit1.1 switchCRT
Parameters (144)
ParameterTypeDefault
Delay after bus voltage recoverytime400
Contact typelistNO (normally open)
Debounce timetime20
Minimum change of value to send [K]float 0…50.5
Cyclic sending intervallistno sending
Threshold 1listnot active
Threshold 2listnot active
Value [°C]float -25…607
Value [°C]float -25…6045
Hysteresislist0.4 K
Digital sensors timeouttime300
Room temperaturelistdisabled
Antistratification temperaturelistdisabled
Outdoor temperaturelistdisabled
Coil temperaturelistdisabled
Flow temperaturelistdisabled
Window contact 1listdisabled
Window contact 2listdisabled
Presence sensor 1listdisabled
Presence sensor 2listdisabled
Filter typelistmedium
Signallistnot inverted
Applicationlistfan-coil
Functionlistheating
Installation typelist2 pipes
Controllerlistexternal
Power status feedbacklistdisabled
Report filter changelistno
Ventilation Object formatlistpercentage [DPT 5.001]
Input 1listdisabled
Offsetlist0.0 °C
Input 2listdisabled
Communication Object timeouttime300
Analog sensors timeouttime300
Inputslistdifferent
Drip tray levellistdisabled
First speed threshold [%]unsignedInt 0…10010
Control typelist3 speed (0…10V)
Cold startlistno
Warm startlistno
Second speed threshold [%]unsignedInt 0…10040
Third speed threshold [%]unsignedInt 0…10070
Hysteresis [%]unsignedInt 0…305
Coil temperatureunsignedInt 28…4035
Coil temperatureunsignedInt 7…1812
Speed control low limit [%]unsignedInt 0…1000
Speed control high limit [%]unsignedInt 0…100100
Antistratificationlistdisabled
Disable from buslistdisabled
Temperature differentiallist2.00 K/m
Hysteresislist0.6 K
Start delaylist0 s
Stop delaylist0 s
Control feedbacklistno
Control typeliston/off
Control can be disabled from buslistno
Valve position feedbacklistdisabled
Valve position after timeoutlistoff
PWM cycle timetime15
Min. control value [%]unsignedInt 0…3015
Max. control value [%]unsignedInt 70…10085
Antiscuff protectionlistdisabled
Frequencylistonce a week
Time intervallist10 s
Auxiliary output typelistvalue from bus
Disable from buslistno
Setpoint typelistrelative
Heating/cooling changeoverlistfrom bus
Temperature for changeover (heating)float 20…5035
Temperature for changeover (cooling)float 5…2016
Changeover cyclic sending intervallistno sending
Comfort setpoint [°C]float 10…5021
Standby offset [0.1 K]signedInt -50…-10-30
Economy offset [0.1 K]signedInt -89…-10-50
Building protection [°C]float 2…107
Proportional band [0.1 K]unsignedInt 0…25530
Integral time [min]unsignedInt 0…2550
Min change of value to send [%]unsignedInt 0…10010
Forced modelistno
Comfort setpoint [°C]float 10…5023
Standby offset [0.1 K]signedInt 10…5030
Economy offset [0.1 K]signedInt 10…8050
Building protection [°C]float 20…5036
Neutral zone [0.1 K]signedInt 10…5020
Summer compensationlistdisabled
Lowest external temperature [°C]unsignedInt 25…4025
Coefficientlist1 K each 4 K external temp. change
Min change to send valuelist0.6 K
Window contacts functionlistdisabled
Time to wait before HVAC changetime60
Presence sensors functionlistdisabled
Uselistcomfort extension
Modeslistcomfort - standby
In case of driplistclose valve and switch fan off
Drip controllistdisabled
Change filter warning after [weeks]unsignedInt 1…12816
Send warningliston filter change only
Send usage timelistno sending (only reading)
Cyclic sending intervallist24 h
Speed at timeoutlistspeed 1
Speed at timeoutlist20%
Output value at the first speedunsignedInt 0…10010
Output value at the second speedunsignedInt 0…10040
Output value at the third speedunsignedInt 0…10070
Communication Objectlistseparated
Valve Object formatlistoutput status [DPT 1.001]
First speed threshold [0.1K]unsignedInt 0…2550
Second speed threshold [0.1K]unsignedInt 0…25510
Third speed threshold [0.1K]unsignedInt 0…25520
Hysteresis [0.1K]list0.3 K
Temperature setpoint [°C]float 10…5021
Temperature setpoint [°C]float 10…5023
Fan speed limit from buslistnot limited
Setpoint CO typelistabsolute
Communication Object typelistseconds [DPT 13.100]
Speed output low limit [%]unsignedInt 0…1000
Speed output high limit [%]unsignedInt 0…100100
Minimum change of value to send [%]unsignedInt 0…305
RoomTemplistno
End of manual operationlisttill first telegram from bus
Frequencylist30 min
Time intervallist2 min
Fan controllistdepending on temperature
Time-scheduled antistratificationlistdisabled
Logic functionlistdisabled
Logic operationlistOR
Output cyclic sending intervallistno sending
Logic object 1listdisabled
Logic object 1 negatedlistno
Logic object 1 read at startuplistno
Logic object 1 default valuelistnone
Logic object 2listdisabled
Logic object 2 negatedlistno
Logic object 2 read at startuplistno
Logic object 2 default valuelistnone
Logic object 3listdisabled
Logic object 3 negatedlistno
Logic object 3 read at startuplistno
Logic object 3 default valuelistnone
Logic object 4listdisabled
Logic object 4 negatedlistno
Logic object 4 read at startuplistno
Logic object 4 default valuelistnone
Logic functionslistdisabled

Version history

ApplicationApp noFingerprintFirst seenSizeFile
APEKHB1TP 0.5 latest$484233D92026-11-25174 KBDownload

About this file

This is the official ETS product database for the Ekinex S.p.A. EK-HB1-TP - Fan-coil actuator/controller (EK-HB1-TP), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Ekinex S.p.A.

All Ekinex S.p.A. products