Dinuy PEK5X001 Actuator RF 1ch Blind / 2ch Switch - 4 Inputs

Actuator RF 1ch Blind / 2ch Switch - 4 Inputs PEK5X001

Dinuy · Order number PEK5X001 · KNX-RF Devices › Actuators › Switch and Shutter/Blind Actuators

Download .knxprod DINUY_PEK5X001 0.0 · 194 KB

Product

ManufacturerDinuy
Product nameActuator RF 1ch Blind / 2ch Switch - 4 Inputs
Order numberPEK5X001
HardwareActuator RF 2ch Switch/blind- 4input ch
MediumKNX RF
Rail mountedNo
RegistrationCertified · 2018-12-18
Languageses-ES, en-US
Catalog entryM-009A_H-009APEK5X001011018-0_HP-2004-00-ACB1_CI-PEK5X001-1
FingerprintACB1
SHA-256409e3eff9658a1c5ad7e144ff98bf2949c6a73285d18f6fdf648c59475bfb0d7
First seen2026-11-25
Markets68 markets

Application program: DINUY_PEK5X001 0.0

Application number$2004
Version0.0
Mask versionMV-27B0 (RF System B)
KNX Data SecureNo
Minimum ETS version5.0
Parameters649
Group objects341
Group objects (341)
NoNameFunctionSizeDPTFlags
1[In1] Disable channel (via bus) 1= Disable, 0 = Enable1 Bit1.3 enableCW
1[In1] Disable temperature functionality (via bus)1 = Disable, 0 = Enable1 Bit1.3 enableCW
2[In1] Switch Telegram1 = On, 0 = Off1 Bit1.1 switchCT
2[In1] Stop / Step Telegram0 = Step Up, 1 = Step Down1 Bit1.7 stepCT
2[In1] Bit value on operationBit value1 Bit1.11 stateCT
2[In1] 2 Bits value on operation2 Bits value2 Bit2.1 switch controlCT
2[In1] Scene control 8 BitsScene control1 Byte18.1 scene controlCT
2[In1] 2 Bytes signed value on operation2 Bytes signed value2 Bytes8.1 pulses differenceCT
2[In1] 2 Bytes floating value on operation2 Bytes floating value2 Bytes9.1 temperature (°C)CT
2[In1] Byte value on operationByte value1 Byte5.10 counter pulses (0..255)CT
2[In1] 4 Bytes value on operation4 Bytes value4 Bytes12.1 counter pulses (unsigned)CT
2[In1] Temperature value OutputTemperature value2 Bytes9.1 temperature (°C)CT
2[In1] Counter direction0 = Up, 1 = Down1 Bit1.8 up/downCW
2[In1] Scene 1 Bit0 = Scene 1, 1 = Scene 21 Bit1.11 stateCT
2[In1] 2 Bytes value on operation2 Bytes value2 Bytes7.1 pulsesCT
3[In1] Switch Long Telegram1 = On, 0 = Off1 Bit1.1 switchCT
3[In1] Reset Counter (via bus)0 = No action, 1 = Reset1 Bit1.15 resetCW
3[In1] Switch 2 Telegram1 = On, 0 = Off1 Bit1.1 switchCT
3[In1] Scene save0 = No action, 1 = Save Scene1 Bit1.3 enableCW
3[In1] 4 Bytes value on Long operation4 Bytes value4 Bytes12.1 counter pulses (unsigned)CT
3[In1] 2 Bytes floating value on Long operation2 Bytes floating value2 Bytes9.1 temperature (°C)CT
3[In1] 2 Bytes signed value on Long operation2 Bytes signed value2 Bytes8.1 pulses differenceCT
3[In1] Bit value on Long operationBit value1 Bit1.11 stateCT
3[In1] 2 Bits value on Long operation2 Bits value2 Bit2.1 switch controlCT
3[In1] Sensor not connected0 = Sensor Ok, 1 = Sensor not connected1 Bit1.11 stateCT
3[In1] Byte value on Long operationByte value1 Byte5.10 counter pulses (0..255)CT
3[In1] 2 Bytes value on Long operation2 Bytes value2 Bytes7.1 pulsesCT
3[In1] Dimming control TelegramDimming control4 Bit3.7 dimming controlCT
3[In1] Move Telegram0 = Up, 1 = Down1 Bit1.8 up/downCT
4[In1] Info Switch (via bus)1 = On, 0 = Off1 Bit1.1 switchCW
4[In1] Request Counter (via bus)1 = Trigger1 Bit1.17 triggerCW
4[In1] Over-Heating Output1 = Over-Heating, 0 = No Over-Heating1 Bit1.5 alarmCT
4[In1] Switch 3 Telegram1 = On, 0 = Off1 Bit1.1 switchCT
5[In1] Info Switch Long (via bus)1 = On, 0 = Off1 Bit1.1 switchCW
5[In1] Counter 32 BitsCounter (0-4.294.967.295)4 Bytes13.1 counter pulses (signed)CRT
5[In1] Over-Cooling Output1 = Over-Cooling, 0 = No Over-Cooling1 Bit1.5 alarmCT
5[In1] Counter 8 BitsCounter (0-255)1 Byte5.10 counter pulses (0..255)CRT
5[In1] Counter 16 BitsCounter (0-65535)2 Bytes7.1 pulsesCRT
5[In1] Switch 4 Telegram1 = On, 0 = Off1 Bit1.1 switchCT
6[In1] Switch 5 Telegram1 = On, 0 = Off1 Bit1.1 switchCT
7[In1] Increase/Decrease (via bus)0 = Up, 1 = Down1 Bit1.8 up/downCW
7[In1] Scene save0 = Scene 1, 1 = Scene 21 Bit1.3 enableCT
8[In2] Disable channel (via bus)1 = Disable, 0 = Enable1 Bit1.3 enableCW
8[In2] Disable temperature functionality (via bus)1 = Disable, 0 = Enable1 Bit1.3 enableCW
9[In2] Switch Telegram1 = On, 0 = Off1 Bit1.1 switchCT
9[In2] 4 Bytes value on operation4 Bytes value4 Bytes12.1 counter pulses (unsigned)CT
9[In2] 2 Bytes signed value on operation2 Bytes signed value2 Bytes8.1 pulses differenceCT
9[In2] Temperature value OutputTemperature value2 Bytes9.1 temperature (°C)CT
9[In2] Stop / Step Telegram0 = Step Up, 1 = Step Down1 Bit1.7 stepCT
9[In2] 2 Bits value on operation2 Bits value2 Bit2.1 switch controlCT
9[In2] 2 Bytes value on operation2 Bytes value2 Bytes7.1 pulsesCT
9[In2] Bit value on operationBit value1 Bit1.11 stateCT
9[In2] Counter direction (via bus)0 = Up, 1 = Down1 Bit1.8 up/downCW
9[In2] Byte value on operationByte value1 Byte5.10 counter pulses (0..255)CT
9[In2] 2 Bytes floating value on operation2 Bytes floating value2 Bytes9.1 temperature (°C)CT
9[In2] Scene 1 Bit0 = Scene 1, 1 = Scene 21 Bit1.11 stateCT
9[In2] Scene control 8 BitsScene control1 Byte18.1 scene controlCT
10[In2] Switch Long Telegram1 = On, 0 = Off1 Bit1.1 switchCT
10[In2] Scene save0 = No action, 1 = Store Scene1 Bit1.3 enableCW
10[In2] Switch 2 Telegram1 = On, 0 = Off1 Bit1.1 switchCT
10[In2] Bit value on Long operationBit value1 Bit1.11 stateCT
10[In2] Reset Counter (via bus)0 = No action, 1 = Reset1 Bit1.15 resetCW
10[In2] Move Telegram0 = Up, 1 = Down1 Bit1.8 up/downCT
10[In2] 2 Bytes floating value on Long operation2 Bytes floating value2 Bytes9.1 temperature (°C)CT
10[In2] 2 Bytes signed value on Long operation2 Bytes signed value2 Bytes8.1 pulses differenceCT
10[In2] 4 Bytes value on Long operation4 Bytes value4 Bytes12.1 counter pulses (unsigned)CT
10[In2] 2 Bits value on Long operation2 Bits value2 Bit2.1 switch controlCT
10[In2] Sensor not connected Output0 = Sensor Ok, 1 = Sensor not connected1 Bit1.11 stateCT
10[In2] Byte value on Long operationByte value1 Byte5.10 counter pulses (0..255)CT
10[In2] 2 Bytes value on Long operation2 Bytes value2 Bytes7.1 pulsesCT
10[In2] Dimming control TelegramDimming control4 Bit3.7 dimming controlCT
11[In2] Info switch (via bus)1 = On, 0 = Off1 Bit1.1 switchCW
11[In2] Switch 3 Telegram1 = On, 0 = Off1 Bit1.1 switchCT
11[In2] Request Counter (via bus)1 = Trigger1 Bit1.17 triggerCW
11[In2] Over-Heating Output1 = Over-Heating, 0 = No Over-Heating1 Bit1.5 alarmCT
12[In2] Info switch Long (via bus)1 = On, 0 = Off1 Bit1.1 switchCW
12[In2] Counter 16 BitsCounter (0-65535)2 Bytes7.1 pulsesCRT
12[In2] Switch 4 Telegram1 = On, 0 = Off1 Bit1.1 switchCT
12[In2] Over-Cooling Output1 = Over-Cooling, 0 = No Over-Cooling1 Bit1.5 alarmCT
12[In2] Counter 8 BitsCounter (0-255)1 Byte5.10 counter pulses (0..255)CRT
12[In2] Counter 32 BitsCounter (0-4.294.967.295)4 Bytes13.1 counter pulses (signed)CRT
13[In2] Switch 5 Telegram1 = On, 0 = Off1 Bit1.1 switchCT
14[In2] Scene save0 = Scene 1, 1 = Scene 21 Bit1.3 enableCT
14[In2] Increase/Decrease (via bus)0 = Up, 1 = Down1 Bit1.8 up/downCW
15[In3] Disable channel (via bus)1 = Disable, 0 = Enable1 Bit1.3 enableCW
15[In3] Disable Temperature functionality (via bus)1 = Disable, 0 = Enable1 Bit1.3 enableCW
16[In3] Switch Telegram1 = On, 0 = Off1 Bit1.1 switchCT
16[In3] Scene control 8 BitsScene control1 Byte18.1 scene controlCT
16[In3] Temperature value OutputTemperature value2 Bytes9.1 temperature (°C)CT
16[In3] 2 Bytes floating value on operation2 Bytes floating value2 Bytes9.1 temperature (°C)CT
16[In3] Byte value on operationByte value1 Byte5.10 counter pulses (0..255)CT
16[In3] Counter direction (via bus)0 = Up, 1 = Down1 Bit1.8 up/downCW
16[In3] Bit value on operationBit value1 Bit1.11 stateCT
16[In3] 2 Bytes value on operation2 Bytes value2 Bytes7.1 pulsesCT
16[In3] 2 Bits value on operation2 Bits value2 Bit2.1 switch controlT
16[In3] Stop / Step Telegram0 = Step Up, 1 = Step Down1 Bit1.7 stepCT
16[In3] 2 Bytes signed value on operation2 Bytes signed value2 Bytes8.1 pulses differenceCT
16[In3] Scene 1 Bit0 = Scene 1, 1 = Scene 21 Bit1.11 stateCT
16[In3] 4 Bytes value on operation4 Bytes value4 Bytes12.1 counter pulses (unsigned)CT
17[In3] 2 Bytes floating value on Long operation2 Bytes floating value2 Bytes9.1 temperature (°C)CT
17[In3] Switch 2 Telegram1 = On, 0 = Off1 Bit1.1 switchCT
17[In3] 2 Bytes signed value on Long operation2 Bytes signed value2 Bytes8.1 pulses differenceCT
17[In3] Scene save0 = No action, 1 = Store save1 Bit1.3 enableCW
17[In3] Move Telegram0 = Up, 1 = Down1 Bit1.8 up/downCT
17[In3] Reset Counter (via bus)0 = No action, 1 = Reset1 Bit1.15 resetCW
17[In3] 2 Bits value on Long operation2 Bits value2 Bit2.1 switch controlCT
17[In3] Sensor not connected Output0 = Sensor Ok, 1 = Sensor not connected1 Bit1.11 stateCT
17[In3] Byte value on Long operationByte value1 Byte5.10 counter pulses (0..255)CT
17[In3] 2 Bytes value on Long operation2 Bytes value2 Bytes7.1 pulsesCT
17[In3] Dimming control TelegramDimming control4 Bit3.7 dimming controlCT
17[In3] Switch Long Telegram1 = On, 0 = Off1 Bit1.1 switchCT
17[In3] Bit value on Long operationBit value1 Bit1.11 stateCT
17[In3] 4 Bytes value on Long operation4 Bytes value4 Bytes12.1 counter pulses (unsigned)CT
18[In3] Request counter (via bus)1 = Trigger1 Bit1.17 triggerCW
18[In3] Over-Heating Output1 = Over-Heating, 0 = No Over-Heating1 Bit1.5 alarmCT
18[In3] Switch 3 Telegram1 = On, 0 = Off1 Bit1.1 switchCT
18[In3] Info switch (via bus)1 = On, 0 = Off1 Bit1.1 switchCW
19[In3] Switch 4 Telegram1 = On, 0 = Off1 Bit1.1 switchCT
19[In3] Over-Cooling Output1 = Over-Cooling, 0 = No Over-Cooling1 Bit1.5 alarmCT
19[In3] Counter 8 BitsCounter (0-255)1 Byte5.10 counter pulses (0..255)CRT
19[In3] Counter 32 BitsCounter (0-4.294.967.295)4 Bytes13.1 counter pulses (signed)CRT
19[In3] Info switch Long (via bus)1 = On, 0 = Off1 Bit1.1 switchCW
19[In3] Counter 16 BitsCounter (0-65535)2 Bytes7.1 pulsesCRT
20[In3] Switch 5 Telegram1 = On, 0 = Off1 Bit1.1 switchCT
21[In3] Increase/Decrease (via bus)0 = Up, 1 = Down1 Bit1.8 up/downCW
21[In3] Scene save0 = Scene 1, 1 = Scene 21 Bit1.3 enableCT
22[In4] Disable channel (via bus)1 = Disable, 0 = Enable1 Bit1.3 enableCW
22[In4] Disable Temperature functionality (via bus)1 = Disable, 0 = Enable1 Bit1.3 enableCW
23[In4] Switch Telegram1 = On, 0 = Off1 Bit1.1 switchCT
23[In4] 2 Bytes floating value on operation2 Bytes floating value2 Bytes9.1 temperature (°C)CT
23[In4] Scene 1 Bit0 = Scene 1, 1 = Scene 21 Bit1.11 stateCT
23[In4] Counter direction (via bus)0 = Up, 1 = Down1 Bit1.8 up/downCW
23[In4] 4 Bytes value on operation4 Bytes value4 Bytes12.1 counter pulses (unsigned)CT
23[In4] Temperature value OutputTemperature value2 Bytes9.1 temperature (°C)CT
23[In4] 2 Bytes value on operation2 Bytes value2 Bytes7.1 pulsesCT
23[In4] 2 Bits value on operation2 Bits value2 Bit2.1 switch controlCT
23[In4] Stop / Step Telegram0 = Step Up, 1 = Step Down1 Bit1.7 stepCT
23[In4] 2 Bytes signed value on operation2 Bytes signed value2 Bytes8.1 pulses differenceCT
23[In4] Bit value on operationBit value1 Bit1.11 stateCT
23[In4] Byte value on operationByte value1 Byte5.10 counter pulses (0..255)CT
23[In4] Scene control 8 BitsScene control1 Byte18.1 scene controlCT
24[In4] 4 Bytes value on Long operation4 Bytes value4 Bytes12.1 counter pulses (unsigned)CT
24[In4] 2 Bytes floating value on Long operation2 Bytes floating value2 Bytes9.1 temperature (°C)CT
24[In4] Move Telegram0 = Up, 1 = Down1 Bit1.8 up/downCT
24[In4] 2 Bytes signed value on Long operation2 Bytes signed value2 Bytes8.1 pulses differenceCT
24[In4] Reset Counter (via bus)0 = No action, 1 = Reset1 Bit1.15 resetCW
24[In4] 2 Bits value on Long operation2 Bits value2 Bit2.1 switch controlCT
24[In4] Sensor not connected Output0 = Sensor Ok, 1 = Sensor not connected1 Bit1.11 stateCT
24[In4] Byte value on Long operationByte value1 Byte5.10 counter pulses (0..255)CT
24[In4] 2 Bytes value on Long operation2 Bytes value2 Bytes7.1 pulsesCT
24[In4] Dimming control TelegramDimming control4 Bit3.7 dimming controlCT
24[In4] Switch Long Telegram1 = On, 0 = Off1 Bit1.1 switchCT
24[In4] Bit value on Long operationBit value1 Bit1.11 stateCT
24[In4] Switch 2 Telegram1 = On, 0 = Off1 Bit1.1 switchCT
24[In4] Scene save0 = No action, 1 = Save Scene1 Bit1.3 enableCW
25[In4] Switch 3 Telegram1 = On, 0 = Off1 Bit1.1 switchCT
25[In4] Info Switch (via bus)1 = On, 0 = Off1 Bit1.1 switchCW
25[In4] Over-Heating Output1 = Over-Heating, 0 = No Over-Heating1 Bit1.5 alarmCT
25[In4] Request Counter (via bus)1 = Trigger1 Bit1.17 triggerCW
26[In4] Counter 32 bitsCounter (0-4.294.967.295)4 Bytes13.1 counter pulses (signed)CRT
26[In4] Over-Cooling Output1 = Over-Cooling, 0 = No Over-Cooling1 Bit1.5 alarmCT
26[In4] Counter 8 BitsCounter (0-255)1 Byte5.10 counter pulses (0..255)CRT
26[In4] Info Switch Long (via bus)1 = On, 0 = Off1 Bit1.1 switchCW
26[In4] Switch 4 Telegram1 = On, 0 = Off1 Bit1.1 switchCT
26[In4] Counter 16 BitsCounter (0-65535)2 Bytes7.1 pulsesCRT
27[In4] Switch 5 Telegram1 = On, 0 = Off1 Bit1.1 switchCT
28[In4] Scene save0 = Scene 1, 1 = Scene 21 Bit1.3 enableCT
28[In4] Increase/Decrease (via bus)0 = Up, 1 = Down1 Bit1.8 up/downCW
30[Out1] Switch Status1 = On, 0= Off1 Bit1.1 switchCT
31[Out1] Switch On/Off1 = On, 0= Off1 Bit1.1 switchCW
32[Out1] Forced positioning 1 bit1 = Forced, 0 = No Forced1 Bit1.3 enableCW
32[Out1] Forced positioning 2 Bits2 Bits value2 Bit2.1 switch controlCW
34[Out1] Change Threshold value1 Byte value1 Byte5.10 counter pulses (0..255)CW
34[Out1] Change Threshold value2 Bytes value2 Bytes7.1 pulsesCW
35[Out1] Threshold input1 Byte value1 Byte5.10 counter pulses (0..255)CW
35[Out1] Threshold Input2 Bytes value2 Bytes7.1 pulsesCW
37[Out1] Logical connection 11 = True, 0 = False1 Bit1.2 booleanCW
38[Out1] Logical connection 21 = True, 0 = False1 Bit1.2 booleanCW
39[Out1] SceneScene control1 Byte18.1 scene controlCW
40[Out1] Set Preset 1/2Telegram 0 --> Set Preset 1, Telegram 1 --> Set Preset 21 Bit1.1 switchCW
41[Out1] Call Preset 1/2Telegram 0 --> Call Preset 1, Telegram 1 --> Call Preset 21 Bit1.3 enableCW
42[Out1] Timed switch 1 = Timed On1 Bit1.10 start/stopCW
43[Out1] Stair lighting Warning1 = Warning, 0 = No warning1 Bit1.1 switchCT
44[Out1] Duration of staircase light (sec)2 Bytes value2 Bytes7.5 time (s)CW
45[Out1] Permanent ON1 = On, 0 = Off1 Bit1.1 switchCW
46[Out1] Disable Time function1 = Disable, 0 = Enable1 Bit1.3 enableCW
50[Out2] Switch Status1 = On, 0 = Off1 Bit1.1 switchCT
51[Out2] Switch On/Off1 = On, 0= Off1 Bit1.1 switchCW
52[Out2] Forced positioning 2 bit2 Bit value2 Bit2.1 switch controlCW
52[Out2] Forced positioning 1 Bit1 = Forced, 0 = No Forced1 Bit1.1 switchCW
54[Out2] Change Threshold value1 Byte value1 Byte5.10 counter pulses (0..255)CW
54[Out2] Change Threshold value2 Bytes value2 Bytes7.1 pulsesCW
55[Out2] Threshold input1 Byte value1 Byte5.10 counter pulses (0..255)CW
55[Out2] Threshold input2 Bytes value2 Bytes7.1 pulsesCW
57[Out2] Logical connection 11 = True, 0 = False1 Bit1.2 booleanCW
58[Out2] Logical connection 21 = True, 0 = False1 Bit1.2 booleanCW
59[Out2] SceneScene control1 Byte18.1 scene controlCW
60[Out2] Set Preset 1/2Telegram 0 --> Set Preset 1, Telegram 1 --> Set Preset 21 Bit1.1 switchCW
61[Out2] Call Preset 1/2Telegram 0 --> Call Preset 1, Telegram 1 --> Call Preset 21 Bit1.3 enableCW
62[Out2] Timed switch 1= Timed On1 Bit1.10 start/stopCW
63[Out2] Stair lighting Warning1 = Warning, 0 = No warning1 Bit1.1 switchCT
64[Out2] Duration of staircase light (sec)2 Bytes value2 Bytes7.5 time (s)CW
65[Out2] Permanent ON1 = On, 0 = Off1 Bit1.1 switchCW
66[Out2] Disable Time function1 = Disable, 0 = Enable1 Bit1.3 enableCW
70[Out] Blind Move Up/Down0 = Up, 1 = Down1 Bit1.8 up/downCW
70[Out] Roller Move Up/Down0 = Up, 1 = Down1 Bit1.8 up/downCW
70[Out] Louver Move Up/Down0 = Up, 1 = Down1 Bit1.8 up/downCW
71[Out] Blind Stop / Step Up/Down0 = Step Up, 1 = Step Down1 Bit1.7 stepCW
71[Out] Roller Stop / Step Up/Down0 = Step Up, 1 = Step Down1 Bit1.7 stepCW
71[Out] Louver Stop / Step Up/Down0 = Step Up, 1 = Step Down1 Bit1.7 stepCW
72[Out] Forced input2 Bits control2 Bit2.1 switch controlCW
73[Out] Wind alarm input 11 = Alarm, 0 = No alarm1 Bit1.5 alarmCW
74[Out] Wind alarm input 21 = Alarm, 0 = No alarm1 Bit1.5 alarmCW
75[Out] Wind alarm input 31 = Alarm, 0 = No alarm1 Bit1.5 alarmCW
76[Out] Rain alarm input 1 = Alarm, 0 = No alarm1 Bit1.5 alarmCW
77[Out] Frost alarm input 1 = Alarm, 0 = No alarm1 Bit1.5 alarmCW
78[Out] Scene inputScene control1 Byte18.1 scene controlCW
79[Out] Info Movement0 = Up, 1 = Down1 Bit1.8 up/downCT
80[Out] Blind position input0h = 0%, 80h = 50%, FFh = 100%1 Byte5.1 percentage (0..100%)CW
80[Out] Louver position Input0h = 0%, 80h = 50%, FFh = 100%1 Byte5.1 percentage (0..100%)CW
80[Out] Roller position Input0h = 0%, 80h = 50%, FFh = 100%1 Byte5.1 percentage (0..100%)CW
81[Out] Slats position input0h = 0%, 80h = 50%, FFh = 100%1 Byte5.1 percentage (0..100%)CW
82[Out] Blind position Info0h = 0%, 80h = 50%, FFh = 100%1 Byte5.1 percentage (0..100%)CT
82[Out] Roller position Info0h = 0%, 80h = 50%, FFh = 100%1 Byte5.1 percentage (0..100%)CT
82[Out] Louver position Info0h = 0%, 80h = 50%, FFh = 100%1 Byte5.1 percentage (0..100%)CT
83[Out] Slats position Info0h = 0%, 80h = 50%, FFh = 100%1 Byte5.1 percentage (0..100%)CT
84[Out] Lux level inputLux value2 Bytes9.4 lux (Lux)CW
84[Out] Solar protection Input1 = On, 0 = Off1 Bit1.1 switchCW
85[Out] Solar protection position input0h = 0%, 80h = 50%, FFh = 100%1 Byte5.1 percentage (0..100%)CW
90[T1] On/Off status Info1 = On; 0 = Off1 Bit1.1 switchCT
91[T1] On/Off Input1= On; 0= Off1 Bit1.1 switchCW
92[T1] Set-point InformationCurrent Set-point2 Bytes9.1 temperature (°C)CT
93[T1] Set-point InputSet-point2 Bytes9.1 temperature (°C)CW
93[T1] Comfort Set-point InputComfort Set-point2 Bytes9.1 temperature (°C)CW
94[T1] OutputOutput (PWM Proportional - Integral)1 Bit1.1 switchCT
94[T1] OutputOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CT
94[T1] Output HeatingOutput (PWM Proportional - Integral)1 Bit1.1 switchCT
94[T1] Output HeatingOutput (2 points with Hysteresis)1 Bit1.1 switchCT
94[T1] Output HeatingOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CT
94[T1] OutputOutput (2 points with Hysteresis)1 Bit1.1 switchCT
95[T1] Output CoolingOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CT
95[T1] Output CoolingOutput (2 points with Hysteresis)1 Bit1.1 switchCT
95[T1] Output CoolingOutput (PWM Proportional - Integral)1 Bit1.1 switchCT
96[T1] Temperature Sensor 1Input Temperature Sensor 12 Bytes9.1 temperature (°C)CW
97[T1] Temperature Sensor 2Input Temperature Sensor 22 Bytes9.1 temperature (°C)CW
98[T1] Special mode Info2 Bytes mode Info2 Bytes22.101 RHCC statusCT
99[T1] Special mode Input 1 Byte1 Byte mode HVAC1 Byte20.102 HVAC modeCW
100[T1] Special mode Economic0=Off; 1=On1 Bit1.1 switchCW
101[T1] Special mode Stand-by0=Off; 1=On1 Bit1.1 switchCW
102[T1] Special mode Protection0=Off; 1=On1 Bit1.1 switchCW
103[T1] Special mode Comfort0=Off; 1=On1 Bit1.1 switchCW
104[T1] Heating or Cooling mode Status0=Cooling; 1=Heating1 Bit1.1 switchCT
105[T1] Heating or Cooling mode0=Cooling; 1=Heating1 Bit1.1 switchCW
106[T1] Window alarm 1 Input0=No alarm; 1=Alarm1 Bit1.5 alarmCW
107[T1] Window alarm 2 Input0=No alarm; 1=Alarm1 Bit1.5 alarmCW
108[T1] Window alarm 3 Input0=No alarm; 1=Alarm1 Bit1.5 alarmCW
109[T1] Window alarm 4 Input0=No alarm; 1=Alarm1 Bit1.5 alarmCW
110[T2] On/Off status Info1 = On; 0 = Off1 Bit1.1 switchCT
111[T2] On/Off Input1 = On; 0 = Off1 Bit1.1 switchCW
112[T2] Set-point InformationCurrent Set-point2 Bytes9.1 temperature (°C)CT
113[T2] Set-point InputSet-point2 Bytes9.1 temperature (°C)CW
113[T2] Comfort Set-point InputComfort Set-point2 Bytes9.1 temperature (°C)CW
114[T2] Output HeatingOutput (PWM Proportional - Integral)1 Bit1.1 switchCT
114[T2] OutputOutput (PWM Proportional - Integral)1 Bit1.1 switchCT
114[T2] OutputOutput (2 points with Hysteresis)1 Bit1.1 switchCT
114[T2] OutputOutput (% Proportional - Integral)1 Byte5.10 counter pulses (0..255)CT
114[T2] Output HeatingOutput (% Proportional - Integral)1 Byte5.10 counter pulses (0..255)CT
114[T2] Output HeatingOutput (2 points with Hysteresis)1 Bit1.1 switchCT
115[T2] Output CoolingOutput (PWM Proportional - Integral)1 Bit1.1 switchCT
115[T2] Output CoolingOutput (% Proportional - Integral)1 Byte5.10 counter pulses (0..255)CT
115[T2] Output CoolingOutput (2 points with Hysteresis)1 Bit1.1 switchCT
116[T2] Temperature sensor 1Input Temperature Sensor 12 Bytes9.1 temperature (°C)CW
117[T2] Temperature sensor 2Input Temperature Sensor 22 Bytes9.1 temperature (°C)CW
118[T2] Special mode Info2 Bytes mode Info2 Bytes22.101 RHCC statusCT
119[T2] Special mode Input 1 Byte1 Byte mode HVAC1 Byte20.102 HVAC modeCW
120[T2] Special mode Economic0=Off; 1=On1 Bit1.1 switchCW
121[T2] Special mode Stand-by0=Off; 1=On1 Bit1.1 switchCW
122[T2] Special mode Protection0=Off; 1=On1 Bit1.1 switchCW
123[T2] Special mode Comfort0=Off; 1=On1 Bit1.1 switchCW
124[T2] Heating or Cooling mode Status0=Cooling; 1=Heating1 Bit1.1 switchCT
125[T2] Heating or Cooling mode0=Cooling; 1=Heating1 Bit1.1 switchCW
126[T2] Window alarm 1 Input0=No alarm; 1=Alarm1 Bit1.5 alarmCW
127[T2] Window alarm 2 Input0=No alarm; 1=Alarm1 Bit1.5 alarmCW
128[T2] Window alarm 3 Input0=No alarm; 1=Alarm1 Bit1.5 alarmCW
129[T2] Window alarm 4 Input0=No alarm; 1=Alarm1 Bit1.5 alarmCW
130[T3] On/Off status Info1 = On; 0 = Off1 Bit1.1 switchCT
131[T3] On/Off Input1= On; 0= Off1 Bit1.1 switchCW
132[T3] Set-point InformationCurrent Set-point2 Bytes9.1 temperature (°C)CT
133[T3] Set-point InputSet-point2 Bytes9.1 temperature (°C)CW
133[T3] Comfort Set-point InputComfort Set-point2 Bytes9.1 temperature (°C)CW
134[T3] Output HeatingOutput (PWM Proportional - Integral)1 Bit1.1 switchCT
134[T3] OutputOutput (2 points with Hysteresis)1 Bit1.1 switchCT
134[T3] OutputOutput (PWM Proportional - Integral)1 Bit1.1 switchCT
134[T3] OutputOutput (% Proportional - Integral)1 Byte5.10 counter pulses (0..255)CT
134[T3] Output HeatingOutput (% Proportional - Integral)1 Byte5.10 counter pulses (0..255)CT
134[T3] Output HeatingOutput (2 points with Hysteresis)1 Bit1.1 switchCT
135[T3] Output CoolingOutput (PWM Proportional - Integral)1 Bit1.1 switchCT
135[T3] Output CoolingOutput (% Proportional - Integral)1 Byte5.10 counter pulses (0..255)CT
135[T3] Output CoolingOutput (2 points with Hysteresis)1 Bit1.1 switchCT
136[T3] Temperature Sensor 1Input Temperature Sensor 12 Bytes9.1 temperature (°C)CW
137[T3] Temperature Sensor 2Input Temperature Sensor 22 Bytes9.1 temperature (°C)CW
138[T3] Special mode Info2 Bytes mode Info2 Bytes22.101 RHCC statusCT
139[T3] Special mode Input 1 Byte1 Byte mode HVAC1 Byte20.102 HVAC modeCW
140[T3] Special mode Economic0=Off; 1=On1 Bit1.1 switchCW
141[T3] Special mode Stand-by0=Off; 1=On1 Bit1.1 switchCW
142[T3] Special mode Protection0=Off; 1=On1 Bit1.1 switchCW
143[T3] Special mode Comfort0=Off; 1=On1 Bit1.1 switchCW
144[T3] Heating or Cooling mode Status0=Cooling; 1=Heating1 Bit1.1 switchCT
145[T3] Heating or Cooling mode0=Cooling; 1=Heating1 Bit1.1 switchCW
146[T3] Window alarm 1 Input0=No alarm; 1=Alarm1 Bit1.5 alarmCW
147[T3] Window alarm 2 Input0=No alarm; 1=Alarm1 Bit1.5 alarmCW
148[T3] Window alarm 3 Input0=No alarm; 1=Alarm1 Bit1.5 alarmCW
149[T3] Window alarm 4 Input0=No alarm; 1=Alarm1 Bit1.5 alarmCW
150[T4] On/Off status Info1 = On; 0 = Off1 Bit1.1 switchCT
151[T4] On/Off Input1 = On; 0 = Off1 Bit1.1 switchCW
152[T4] Set-point InformationCurrent Set-point2 Bytes9.1 temperature (°C)CT
153[T4] Set-point InputSet-point2 Bytes9.1 temperature (°C)CW
153[T4] Comfort Set-point InputComfort Set-point2 Bytes9.1 temperature (°C)CW
154[T4] Output HeatingOutput (PWM Proportional - Integral)1 Bit1.1 switchCT
154[T4] OutputOutput (2 points with Hysteresis)1 Bit1.1 switchCT
154[T4] OutputOutput (PWM Proportional - Integral)1 Bit1.1 switchCT
154[T4] OutputOutput (% Proportional - Integral)1 Byte5.10 counter pulses (0..255)CT
154[T4] Output HeatingOutput (% Proportional - Integral)1 Byte5.10 counter pulses (0..255)CT
154[T4] Output HeatingOutput (2 points with Hysteresis)1 Bit1.1 switchCT
155[T4] Output CoolingOutput (PWM Proportional - Integral)1 Bit1.1 switchCT
155[T4] Output CoolingOutput (2 points with Hysteresis)1 Bit1.1 switchCT
155[T4] Output CoolingOutput (% Proportional - Integral)1 Byte5.10 counter pulses (0..255)CT
156[T4] Temperature Sensor 1Input Temperature Sensor 12 Bytes9.1 temperature (°C)CW
157[T4] Temperature Sensor 2Input Temperature Sensor 22 Bytes9.1 temperature (°C)CW
158[T4] Special mode Info2 Bytes mode Info2 Bytes22.101 RHCC statusCT
159[T4] Special mode Input 1 Byte1 Byte mode HVAC1 Byte20.102 HVAC modeCW
160[T4] Special mode Economic0=Off; 1=On1 Bit1.1 switchCW
161[T4] Special mode Stand-by0=Off; 1=On1 Bit1.1 switchCW
162[T4] Special mode Protection0=Off; 1=On1 Bit1.1 switchCW
163[T4] Special mode Comfort0=Off; 1=On1 Bit1.1 switchCW
164[T4] Heating or Cooling mode Status0=Cooling; 1=Heating1 Bit1.1 switchCT
165[T4] Heating or Cooling mode0=Cooling; 1=Heating1 Bit1.1 switchCW
166[T4] Window alarm 1 Input0=No alarm; 1=Alarm1 Bit1.5 alarmCW
167[T4] Window alarm 2 Input0=No alarm; 1=Alarm1 Bit1.5 alarmCW
168[T4] Window alarm 3 Input0=No alarm; 1=Alarm1 Bit1.5 alarmCW
169[T4] Window alarm 4 Input0=No alarm; 1=Alarm1 Bit1.5 alarmCW
Parameters (249)
ParameterTypeDefault
RASTRO_ETSunsignedInt 0…25516
Function of channel 1listNot assigned
Debounce timelist10mSec
Distinction between Short and Long actionunsignedInt 0…10
Contact typelistNormally Open
Long action after...list0,3 Sec
Number of objects for Short/Long operationlist1
Short actionlistOn
Long actionlistOn
Cyclic transmission?listNo
Action after Closing contactlistOn
Action after Opening contactlistOn
Transmit state on bus voltage recoveryunsignedInt 0…10
Cycle base timelist1 Sec
Factor (Total time = Base x Factor)unsignedInt 0…2557
Dimming functionalitylistDimming and Switch
Action after operationlistBrighter/Darker
Action after Long operationlistBrighter/Darker
Save Scene on Long operationunsignedInt 0…10
Maximum time between two operationslist0,5 Sec
Number of operationslist2
Switch 1 operationlistOn
Switch 2 operationlistOn
Switch 3 operationlistOn
Switch 4 operationlistOn
Number of objectslist2
Functional constructionlist1 Pushbutton
Shutter functionalitylistShort=Step, Long=Move
Action after Long operationlistMove Up
Action after Short operationlistStep Down
Value type on Short operationlist1 Bit
Value type on Long operationlist1 Bit
Signlist+
Integer partunsignedInt 0…990
Decimal partunsignedInt 0…990
2 Bytes valueunsignedInt 0…655350
2 Bytes signed valuesignedInt -32768…327670
4 Bytes valueunsignedInt 0…42949672950
Bit valuelist0
2 Bits valuelist"00"
1 Byte valueunsignedInt 0…2550
Value type on operationlist1 Bit
Type of Scene controllist8 bit scene
Scene numberunsignedInt 1…641
Action after Short operationlistRecall
Save ScenelistNo
Scene number 1/2?unsignedInt 1…21
Data counter widthlist8
Start value (0-255)unsignedInt 0…2550
Start value (0-65535)unsignedInt 0…655350
Start value (0-4.294.967.295)unsignedInt 0…42949672950
Temperature value base timelist1 Min
Temperature variation to sendunsignedInt 5…2005
Protection alarmslistNo protection
HysteresisunsignedInt 0…500
Over-Heating temperaturelist-30
Over-Cooling temperaturelist-30
"Temperature functionality" enabled after bus recovery voltageunsignedInt 0…10
Temperature sensor calibration valuelist0
Function of channel 2listNot assigned
Cyclic transmissionlistNo
Over-Heating Temperaturelist-30
Over-Cooling Temperaturelist-30
Temperature Sensor calibration valuelist0
Function of channel 3listNot assigned
Function of channel 4listNot assigned
Enable Thermostat 1unsignedInt 0…10
ModelistCooling Thermostat
Reference Temperature SourcelistOne source
Thermostat always onunsignedInt 0…10
State after bus recovery voltagelistOff
Enable turn-on Thermostat when Special command arrivesunsignedInt 0…10
Send Thermostat Set-point after bus recovery voltageunsignedInt 0…10
Enable automatic mode changeunsignedInt 0…10
Mode after bus recovery voltagelistCooling Thermostat
Control objectlistDifferent objects for heating and cooling
Set-point modelistAbsolute Set-point mode
Initial Set-point after bus recovery voltageunsignedInt 5…4524
Save Set-point after mode change via objectunsignedInt 0…10
Mode after bus recovery voltagelistComfort
Enable 1 Bit mode objectslistDisable
Enable Window protectionunsignedInt 0…10
Comfort mode Set-pointunsignedInt 5…4522
Offset for Stand-by Set-point modelist-100
Offset for Economic Set-point modelist-100
Set-point for protection from FreezingunsignedInt 0…158
Comfort mode Set-pointunsignedInt 5…455
Offset for Stand-by Set-point modeunsignedInt 0…9964
Offset for Economic Set-point modeunsignedInt 0…9996
Over-temperature protection Set-pointunsignedInt 30…4540
Regulation modelistTwo points with hysteresis control
Upper HysteresisunsignedInt 5…4510
Lower HysteresisunsignedInt 5…4510
Forwarding period (0=Disable)unsignedInt 0…2550
PWM typelistPWM (1bit)
PI cycle timeunsignedInt 0…255255
Proportional bandunsignedInt 0…155
Attenuation factorunsignedInt 0…9931
Maximum Integral component (%)unsignedInt 0…995
Enable Thermostat 2unsignedInt 0…10
Over-Temperature protection Set-pointunsignedInt 30…4540
Enable Thermostat 3unsignedInt 0…10
Enable Thermostat 4unsignedInt 0…10
Transmision and switching delay after recovery of bus voltage (2..255s)unsignedInt 2…2552
Operating modelist2-channel Switch Actuator
Status response of Switching statelistNo
Object value Switching statuslistClosed=1, Open=0
Reaction after Bus faillistOpen contact
Object "Switch" value after bus recovery voltagelistSet object to "0"
Output polaritylistNormally Open contact
Enable Time functionunsignedInt 0…10
Time functionlistStaircase light time switch
Value object "Disable Time function" after bus recovery voltagelist"0": Enable time functions
Enable Preset functionunsignedInt 0…10
Enable Scenes (8 bits) functionunsignedInt 0…10
Enable Logical functionsunsignedInt 0…10
Enable "Forced" functionunsignedInt 0…10
Enable "Threshold" functionunsignedInt 0…10
Staircase light time switch timing (sec)unsignedInt 0…655350
Timer is retriggerableunsignedInt 0…10
Staircase light time switch can be switched offlistON with "1", OFF with "0"
Warning before end of timelistNo
Warning time to add (sec)unsignedInt 0…6553516
Staircase time changeable via objectunsignedInt 0…10
On delay time (sec)unsignedInt 0…655351
Off delay time (sec)unsignedInt 0…655351
Flashing when object "Timed switch" islistOn (1)
Flash On time (sec)unsignedInt 0…655355
Flash Off time (sec)unsignedInt 0…655355
Reaction on Preset 1 (telegram 0)listNo reaction
Reaction on Preset 2 (telegram 1)listNo reaction
Preset can be set via busunsignedInt 0…10
Scene 1 numberlistScene 1
Scene 1 Preset valuelistOff
Scene 2 numberlistScene 2
Scene 2 Preset ValuelistOff
Scene 3 numberlistScene 3
Scene 3 Preset ValuelistOff
Scene 4 numberlistScene 4
Scene 4 Preset ValuelistOff
Scene 5 numberlistScene 5
Scene 5 Preset ValuelistOff
Logical connection 1 enableunsignedInt 0…11
Logical connection 1 functionlistAND
Logical connection 1 invertedunsignedInt 0…10
Object value "Logical connection 1" after bus recovery voltagelistOn
Logical connection 2 enableunsignedInt 0…10
Logical connection 2 functionlistAND
Logical connection 2 invertedunsignedInt 0…10
Object value "Logical connection 2" after bus recovery voltagelistOff
Object "Forced" typelist1 bit object
Object "Forced" polaritylistObject forced "1" --> Switch Off
Object "Forced" state after bus recovery voltagelistNot forced
Data type of object "Threshold Input"list1 Byte (0..255)
Change Threshold value 1 over the busunsignedInt 0…10
Threshold value 1 (0..255)unsignedInt 0…255255
Threshold value 2 (0..255)unsignedInt 0…2550
Threshold value 1 (0..65535)unsignedInt 0…6553550000
Threshold value 2 (0..65535)unsignedInt 0…655350
Threshold values define HysteresisunsignedInt 0…10
Threshold value after bus recovery voltageunsignedInt 0…2550
Threshold value after bus recovery voltageunsignedInt 0…655350
Object value < Threshold value 1listNo reaction
Object value > Threshold value 2listNo reaction
Value 1 ≤ Object value ≤ Value 2listNo reaction
Reaction after bus faillistOpen contact
Value object "Disable time function" after bus recovery voltagelist"0": Enable time functions
Type of devicelistVenecian Blind
Reaction after bus faillistStop
Behaviour after bus recovery voltagelistNo action
Venting Louver position (0-100%) after bus recovery voltageunsignedInt 0…1000
Position Slats (0-100%) after bus recovery voltageunsignedInt 0…1000
Extra time for "Up" movement (%)unsignedInt 0…300
Forced vs Weather alarm Prioritylist1-Forced operation 2-Weather alarm
Reversion Pause Time (msec)unsignedInt 499…5000500
Step operation possiblelistNo (only Stop)
Step time duration (tenths of a second)unsignedInt 2…60010
Roller movement Time duration (sec)unsignedInt 1…36001
Slats movement time duration (tenths of a second)unsignedInt 2…60020
Time to send "Current position" (sec)unsignedInt 60…360060
Time to send "Slats position" (sec)unsignedInt 60…360060
Enable object "Movement Info"unsignedInt 0…10
Enable Security featuresunsignedInt 0…10
Enable object "Wind Alarm 1"unsignedInt 0…10
Enable object "Wind Alarm 2"unsignedInt 0…10
Enable object "Wind Alarm 3"unsignedInt 0…10
Enable object "Rain Alarm"unsignedInt 0…10
Enable object "Frost alarm"unsignedInt 0…10
Enable Wind alarm WatchdogunsignedInt 0…10
Watchdog Wind alarm time (sec)unsignedInt 10…655353600
Enable Rain Alarm WatchdogunsignedInt 0…10
Rain alarm Watchdog time (sec)unsignedInt 10…6553510
Enable Frost alarm WatchdogunsignedInt 0…10
Frost alarm Watchdog time (sec)unsignedInt 10…6553510
Response to Wind alarmlistNo action
Behaviour at the end of the Wind alarmlistNo action
Response to Rain alarmlistNo action
Behaviour at the end of the Rain alarmlistNo action
Response to Frost alarmlistNo action
Behaviour at the end of the Frost alarmlistNo action
Weather Alarms prioritylistWind > Rain > Frost
Enable Sun protectionunsignedInt 0…10
Protection object typelist1 Bit On/Off protection object
Solar protection object polaritylist"1": Sun protection On
Lux value to initiate protectionunsignedInt 1…36001000
Lux value to end protectionunsignedInt 1…3600500
Delay time to initiate Solar protection (sec)unsignedInt 1…36001
Solar protection ON actionlistNo action
Scene numberlistScene 1
Position (%)unsignedInt 0…1000
Slats position (%)unsignedInt 0…1000
Delay time to end Solar protection (sec)unsignedInt 1…36001
Solar protection end actionlistNo action
Enable Scene functionalityunsignedInt 0…10
Scene 1 Position (%)unsignedInt 0…1000
Scene 2 Position (%)unsignedInt 0…1000
Scene 3 Position (%)unsignedInt 0…1000
Scene 4 Position (%)unsignedInt 0…1000
Scene 5 Position (%)unsignedInt 0…1000
Scene 6 numberlistScene 6
Scene 6 Position (%)unsignedInt 0…1000
Scene 7 numberlistScene 7
Scene 7 Position (%)unsignedInt 0…1000
Scene 8 numberlistScene 8
Scene 8 position (%)unsignedInt 0…1000
Scene 1 Position Slats (%)unsignedInt 0…1000
Scene 2 Position Slats (%)unsignedInt 0…1000
Scene 3 Position Slats (%)unsignedInt 0…1000
Scene 4 Position Slats (%)unsignedInt 0…1000
Scene 5 Position Slats (%)unsignedInt 0…1000
Scene 6 Position Slats (%)unsignedInt 0…1000
Scene 7 Position Slats (%)unsignedInt 0…1000
Scene 8 position slats (%)unsignedInt 0…1000
Enable Forced functionunsignedInt 0…10
Forced state after bus recovery voltagelistNot Forced
Fabric tensioning time (sec)unsignedInt 0…2550
Enable object "Info position Blind %"unsignedInt 0…10
Enable object "Info position Slats %"unsignedInt 0…10
Blind position (0-100%) after bus recovery voltageunsignedInt 0…1000
Roller position (0-100%) after bus recovery voltageunsignedInt 0…1000
Blind movement time duration (sec)unsignedInt 1…36001
Louver movement time duration (sec)unsignedInt 1…36001
Enable object "Info position Roller %"unsignedInt 0…10
Enable object "Info position Louver %"unsignedInt 0…10
Initial Comfort Set-point after bus recovery voltageunsignedInt 5…4524
Save Offset after mode change via objectunsignedInt 0…10
Factor time to send temperature (Total time = Base x Factor) (0=Disable send)unsignedInt 0…2557
Action after operationlistMove Up
Action after operationlistMove Up

Version history

ApplicationApp noFingerprintFirst seenSizeFile
DINUY_PEK5X001 0.0 latest$2004ACB12026-11-25194 KBDownload

About this file

This is the official ETS product database for the Dinuy Actuator RF 1ch Blind / 2ch Switch - 4 Inputs (PEK5X001), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Dinuy

All Dinuy products