Dinuy RE K5X RGB DINUY RF 3-channel LED Strip Dimmer_4input ch

DINUY RF 3-channel LED Strip Dimmer_4input ch RE K5X RGB

Dinuy · Order number RE K5X RGB · KNX-RF Devices › Actuators › Dimming Actuators

Download .knxprod DINUY_REK5XRGB 0.0 · 225 KB

Product

ManufacturerDinuy
Product nameDINUY RF 3-channel LED Strip Dimmer_4input ch
Order numberRE K5X RGB
HardwareDINUY RF 3-channel LED Strip Dimmer_4input ch
MediumKNX RF
Rail mountedNo
RegistrationCertified · 2019-05-10
Languageses-ES, en-GB, en-US
Catalog entryM-009A_H-009AREK5XRGB201218-0_HP-2007-00-7CBC_CI-RE.20K5X.20RGB-1
Fingerprint7CBC
SHA-256451bb09ef768bb572cb78604e1f129fddf8ecefded07a2a358675ee90fb9e4cd
First seen2026-11-25
Markets68 markets

Application program: DINUY_REK5XRGB 0.0

Application number$2007
Version0.0
Mask versionMV-27B0 (RF System B)
KNX Data SecureNo
Minimum ETS version5.0
Parameters863
Group objects337
Group objects (337)
NoNameFunctionSizeDPTFlags
1[Red] Switch On/Off Input1 = On, 0= Off1 Bit1.1 switchCW
2[Red] Relative Set value control InputDimming4 Bit3.7 dimming controlCW
2[RGB Red] Relative Set value control InputRED Dimming4 Bit3.7 dimming controlCW
3[Red] Absolute Set value control InputDimming value1 Byte5.1 percentage (0..100%)CW
4[Red] Timed Start Stop Input1 = Start; 0 = Stop1 Bit1.10 start/stopCW
5[Red] Forced InputForced control2 Bit2.3 enable controlCW
6[Red] Scene Number InputScene control1 Byte18.1 scene controlCW
7[Red] Info Switch On-Off Output1 = On, 0 = Off1 Bit1.1 switchCT
8[Red] Info Actual Dimming Value OutputDimming value1 Byte5.1 percentage (0..100%)CT
9[Red] Dimming Speed (from 1% to 100%)100 mSec units2 Bytes7.4 time (100 ms)CW
10[Red] Overload alarm1 = Overload; 0 = No Overload1 Bit1.5 alarmCT
16[Green] SwitchOnOff Input1 = On, 0= Off1 Bit1.1 switchCW
17[Green] Relative Set value control InputDimming4 Bit3.7 dimming controlCW
17[RGB Green] Relative Set value control InputGREEN Dimming4 Bit3.7 dimming controlCW
18[Green] Absolute Set value control InputDimming value1 Byte5.1 percentage (0..100%)CW
19[Green] Timed Start Stop Input1 = Start; 0 = Stop1 Bit1.10 start/stopCW
20[Green] Forced InputForced control2 Bit2.3 enable controlCW
21[Green] Scene Number InputScene control1 Byte18.1 scene controlCW
22[Green] Info Switch On-Off Output1 = On, 0 = Off1 Bit1.1 switchCT
23[Green] Info Actual Dimming Value OutputDimming value1 Byte5.1 percentage (0..100%)CT
24[Green] Dimming Speed (from 1% to 100%)100 mSec units2 Bytes7.4 time (100 ms)CW
25[Green] Overload alarm1 = Overload; 0 = No Overload1 Bit1.5 alarmCT
31[Blue] SwitchOnOff Input1 = On, 0= Off1 Bit1.1 switchCW
32[Blue] Relative Set value control InputDimming4 Bit3.7 dimming controlCW
32[RGB Blue] Relative Set value control InputBLUE Dimming4 Bit3.7 dimming controlCW
33[Blue] Absolute Set value control InputDimming value1 Byte5.1 percentage (0..100%)CW
34[Blue] Timed Start Stop Input1 = Start; 0 = Stop1 Bit1.10 start/stopCW
35[Blue] Forced InputForced control2 Bit2.3 enable controlCW
36[Blue] Scene Number InputScene control1 Byte18.1 scene controlCW
37[Blue] Info Switch On-Off Output1 = On, 0 = Off1 Bit1.1 switchCT
38[Blue] Info Actual Dimming Value OutputDimming value1 Byte5.1 percentage (0..100%)CT
39[Blue] Dimming Speed (from 1% to 100%)100 mSec units2 Bytes7.4 time (100 ms)CW
40[Blue] Overload alarm1 = Overload; 0 = No Overload1 Bit1.5 alarmCT
50[RGB] SwitchOnOff Input1 = On, 0= Off1 Bit1.1 switchCW
51[RGB] RGB Colour value InputRGB colour3 Bytes232.600 RGB value 3x(0..255)CW
52[RGB] Relative Set value control InputRGB Dimming4 Bit3.7 dimming controlCW
53RGB_DIMMING_ABSRGB_DIMMING_ABS1 Byte5.1 percentage (0..100%)CW
54[RGB] Timed Start-Stop Input1 = Start; 0 = Stop1 Bit1.1 switchCW
55[RGB] Forced InputForced control2 Bit2.3 enable controlCW
56[RGB] Scene Number InputScene control1 Byte18.1 scene controlCW
57[RGB] Info Switch On-Off Output1 = On, 0 = Off1 Bit1.1 switchCT
58[RGB] Dimming Speed (from 1% to 100%)100 mSec units2 Bytes7.4 time (100 ms)CW
59[RGB] Overload alarm1 = Overload; 0 = No Overload1 Bit1.5 alarmCT
65Sequence 1 SwitchOnOff1 = On, 0= Off1 Bit1.1 switchCW
66Sequence 2 SwitchOnOff1 = On, 0= Off1 Bit1.1 switchCW
67Sequence 3 SwitchOnOff1 = On, 0= Off1 Bit1.1 switchCW
68Sequence 4 SwitchOnOff1 = On, 0= Off1 Bit1.1 switchCW
69Sequence 5 SwitchOnOff1 = On, 0= Off1 Bit1.1 switchCW
70Info Secuence 1 On-Off Output1 = On, 0= Off1 Bit1.1 switchCT
71Info Secuence 2 On-Off Output1 = On, 0= Off1 Bit1.1 switchCT
72Info Secuence 3 On-Off Output1 = On, 0= Off1 Bit1.1 switchCT
73Info Secuence 4 On-Off Output1 = On, 0= Off1 Bit1.1 switchCT
74Info Secuence 5 On-Off Output1 = On, 0= Off1 Bit1.1 switchCT
80[In1] Disable temperature functionality (via bus) 1 = Disable, 0 = Enable1 Bit1.3 enableCW
80[In1] Disable channel (via bus) 1 = Disable, 0 = Enable1 Bit1.3 enableCW
81[In1] Temperature value OutputTemperature value2 Bytes9.1 temperature (°C)CT
81[In1] Bit value after operationBit value1 Bit1.11 stateCT
81[In1] Stop / Step0 = Step Up, 1 = Step Down1 Bit1.7 stepCT
81[In1] 2 Bits value after operation2 Bits value2 Bit2.1 switch controlCT
81[In1] Counter direction (via bus)0 = Up, 1 = Down1 Bit1.8 up/downCW
81[In1] Switch1 = On, 0 = Off1 Bit1.1 switchCT
81[In1] 2 Bytes floating value after operation2 Bytes floating value2 Bytes9.1 temperature (°C)CT
81[In1] Byte value after operationByte value1 Byte5.10 counter pulses (0..255)CT
81[In1] 4 Bytes value after operation4 Bytes value4 Bytes12.1 counter pulses (unsigned)CT
81[In1] 2 Bytes signed value after operation2 Bytes signed value2 Bytes8.1 pulses differenceCT
81[In1] Scene control 8 bitsScene control1 Byte18.1 scene controlCT
81[In1] Scene 1 bit0 = Scene 1, 1 = Scene 21 Bit1.11 stateCT
81[In1] 2 Bytes value after operation2 Bytes value2 Bytes7.1 pulsesCT
81[In1] RGB Colour value OutputRGB colour3 Bytes232.600 RGB value 3x(0..255)CT
82[In1] Bit value after Long operationBit value1 Bit1.11 stateCT
82[In1] Reset Counter (via bus)0 = No action, 1 = Reset1 Bit1.15 resetCW
82[In1] Switch Long1 = On, 0 = Off1 Bit1.1 switchCT
82[In1] 2 Bytes signed value after Long operation2 Bytes signed value2 Bytes8.1 pulses differenceCT
82[In1] Move0 = Up, 1 = Down1 Bit1.8 up/downCT
82[In1] DimmingDimming4 Bit3.7 dimming controlCT
82[In1] 2 Bytes value after Long operation2 Bytes value2 Bytes7.1 pulsesCT
82[In1] 2 Bits value after Long operation2 Bits value2 Bit2.1 switch controlCT
82[In1] 2 Bytes floating value after Long operation2 Bytes floating value2 Bytes9.1 temperature (°C)CT
82[In1] 4 Bytes value after Long operation4 Bytes value4 Bytes12.1 counter pulses (unsigned)CT
82[In1] Scene save0 = No action, 1 = Save Scene1 Bit1.3 enableCW
82[In1] Switch 21 = On, 0 = Off1 Bit1.1 switchCT
82[In1] Sensor not connected Output0 = Sensor Ok, 1 = Sensor not connected1 Bit1.11 stateCT
82[In1] Byte value after Long operationByte value1 Byte5.10 counter pulses (0..255)CT
83[In1] Info Switch (via bus)1 = On, 0 = Off1 Bit1.1 switchCW
83[In1] Request Counter (via bus)1 = Trigger1 Bit1.17 triggerCW
83[In1] Over-Heating Output1 = Over-Heating, 0 = No Over-Heating1 Bit1.5 alarmCT
83[In1] Switch 31 = On, 0 = Off1 Bit1.1 switchCT
84[In1] Info Switch Long (via bus)1 = On, 0 = Off1 Bit1.1 switchCW
84[In1] Counter 8 bitsCounter (0-255)1 Byte5.10 counter pulses (0..255)CT
84[In1] Counter 32 bitsCounter (0-4.294.967.295)4 Bytes13.1 counter pulses (signed)CT
84[In1] Over-Cooling Output1 = Over-Cooling, 0 = No Over-Cooling1 Bit1.5 alarmCT
84[In1] Counter 16 bitsCounter (0-65535)2 Bytes7.1 pulsesCT
84[In1] Switch 41 = On, 0 = Off1 Bit1.1 switchCT
85[In1] Switch 51 = On, 0 = Off1 Bit1.1 switchCT
86[In1] Scene save0 = Scene 1, 1 = Scene 21 Bit1.3 enableCT
86[In1] Increase/Decrease (via bus)0 = Up, 1 = Down1 Bit1.8 up/downCW
87[In2] Disable temperature functionality (via bus)1 = Disable, 0 = Enable1 Bit1.3 enableCW
87[In2] Disable channel (via bus)1 = Disable, 0 = Enable1 Bit1.3 enableCW
88[In2] Scene control 8 BitsScene control1 Byte18.1 scene controlCT
88[In2] Scene 1 Bit0 = Scene 1, 1 = Scene 21 Bit1.11 stateCT
88[In2] Stop / Step0 = Step Up, 1 = Step Down1 Bit1.7 stepCT
88[In2] Temperature value outputTemperature value2 Bytes9.1 temperature (°C)CT
88[In2] Counter direction (via bus)0 = Up, 1 = Down1 Bit1.8 up/downCW
88[In2] 2 Bytes value after operation2 Bytes value2 Bytes7.1 pulsesCT
88[In2] Bit value after operationBit value1 Bit1.11 stateCT
88[In2] 2 Bits value after operation2 Bits value2 Bit2.1 switch controlCT
88[In2] Switch1 = On, 0 = Off1 Bit1.1 switchCT
88[In2] 2 Bytes floating value after operation2 Bytes floating value2 Bytes9.1 temperature (°C)CT
88[In2] Byte value after operationByte value1 Byte5.10 counter pulses (0..255)CT
88[In2] 4 Bytes value after operation4 Bytes value4 Bytes12.1 counter pulses (unsigned)CT
88[In2] 2 Bytes signed value after operation2 Bytes signed value2 Bytes8.1 pulses differenceCT
88[In2] RGB Colour value outputRGB colour3 Bytes232.600 RGB value 3x(0..255)CT
89[In2] Byte value after Long operationByte value1 Byte5.10 counter pulses (0..255)CT
89[In2] 2 Bytes value after Long operation2 Bytes value2 Bytes7.1 pulsesCT
89[In2] Reset Counter (via bus)0 = No action, 1 = Reset1 Bit1.15 resetCW
89[In2] Bit value after Long operationBit value1 Bit1.11 stateCT
89[In2] Switch 21 = On, 0 = Off1 Bit1.1 switchCT
89[In2] 2 Bytes signed value after Long operation2 Bytes signed value2 Bytes8.1 pulses differenceCT
89[In2] 4 Bytes value after Long operation4 Bytes value4 Bytes12.1 counter pulses (unsigned)CT
89[In2] Scene save0 = No action, 1 = Store Scene1 Bit1.3 enableCW
89[In2] 2 Bytes floating value after Long operation2 Bytes floating value2 Bytes9.1 temperature (°C)CT
89[In2] Move0 = Up, 1 = Down1 Bit1.8 up/downCT
89[In2] DimmingDimming4 Bit3.7 dimming controlCT
89[In2] Sensor not connected Output0 = Sensor Ok, 1 = Sensor not connected1 Bit1.11 stateCT
89[In2] Switch Long1 = On, 0 = Off1 Bit1.1 switchCT
89[In2] 2 Bits value on Long operation2 Bits value2 Bit2.1 switch controlCT
90[In2] Request Counter (via bus)1 = Trigger1 Bit1.17 triggerCW
90[In2] Over-Heating Output1 = Over-Heating, 0 = No Over-Heating1 Bit1.5 alarmCT
90[In2] Info Switch (via bus)1 = On, 0 = Off1 Bit1.1 switchCW
90[In2] Switch 31 = On, 0 = Off1 Bit1.1 switchCT
91[In2] Counter 16 BitsCounter (0-65535)2 Bytes7.1 pulsesCT
91[In2] Over-Cooling Output1 = Over-Cooling, 0 = No Over-Cooling1 Bit1.5 alarmCT
91[In2] Counter 8 BitsCounter (0-255)1 Byte5.10 counter pulses (0..255)CT
91[In2] Counter 32 BitsCounter (0-4.294.967.295)4 Bytes13.1 counter pulses (signed)CT
91[In2] Switch 41 = On, 0 = Off1 Bit1.1 switchCT
91[In2] Info Switch Long (via bus)1 = On, 0 = Off1 Bit1.1 switchCW
92[In2] Switch 51 = On, 0 = Off1 Bit1.1 switchCT
93[In2] Scene save0 = Scene 1, 1 = Scene 21 Bit1.3 enableCT
93[In2] Increase/Decrease (via bus)0 = Up, 1 = Down1 Bit1.8 up/downCW
94[In3] Disable temperature functionality (via bus)1 = Disable, 0 = Enable1 Bit1.3 enableCW
94[In3] Disable channel (via bus)1 = Disable, 0 = Enable1 Bit1.3 enableCW
95[In3] Scene control 8 BitsScene control1 Byte18.1 scene controlCT
95[In3] Byte value after operationByte value1 Byte5.10 counter pulses (0..255)CT
95[In3] Counter direction (via bus)0 = Up, 1 = Down1 Bit1.8 up/downCW
95[In3] Switch1 = On, 0 = Off1 Bit1.1 switchCT
95[In3] 4 Bytes value after operation4 Bytes value4 Bytes12.1 counter pulses (unsigned)CT
95[In3] Scene 1 Bit0 = Scene 1, 1 = Scene 21 Bit1.11 stateCT
95[In3] 2 Bytes signed value after operation2 Bytes signed value2 Bytes8.1 pulses differenceCT
95[In3] Stop / Step0 = Step Up, 1 = Step Down1 Bit1.7 stepCT
95[In3] 2 Bits value after operation2 Bits value2 Bit2.1 switch controlCT
95[In3] 2 Bytes value after operation2 Bytes value2 Bytes7.1 pulsesCT
95[In3] Bit value after operationBit value1 Bit1.11 stateCT
95[In3] Temperature value OutputTemperature value2 Bytes9.1 temperature (°C)CT
95[In3] 2 Bytes floating value after operation2 Bytes floating value2 Bytes9.1 temperature (°C)CT
95[In3] RGB Colour value outputRGB colour3 Bytes232.600 RGB value 3x(0..255)CT
96[In3] 2 Bytes signed value after Long operation2 Bytes signed value2 Bytes8.1 pulses differenceCT
96[In3] Switch 21 = On, 0 = Off1 Bit1.1 switchCT
96[In3] 2 Bytes floating value after Long operation2 Bytes floating value2 Bytes9.1 temperature (°C)CT
96[In3] 4 Bytes value after Long operation4 Bytes value4 Bytes12.1 counter pulses (unsigned)CT
96[In3] Bit value after Long operationBit value1 Bit1.11 stateCT
96[In3] Switch Long1 = On, 0 = Off1 Bit1.1 switchCT
96[In3] 2 Bytes value after Long operation2 Bytes value2 Bytes7.1 pulsesCT
96[In3] Byte value after Long operationByte value1 Byte5.10 counter pulses (0..255)CT
96[In3] DimmingDimming4 Bit3.7 dimming controlCT
96[In3] 2 Bits value after Long operation2 Bits value2 Bit2.1 switch controlCT
96[In3] Reset counter (via bus)0 = No action, 1 = Reset1 Bit1.15 resetCW
96[In3] Scene save0 = No action, 1 = Store save1 Bit1.3 enableCW
96[In3] Sensor not connected Output0 = Sensor Ok, 1 = Sensor not connected1 Bit1.11 stateCT
96[In3] Move0 = Up, 1 = Down1 Bit1.8 up/downCT
97[In3] Switch 31 = On, 0 = Off1 Bit1.1 switchCT
97[In3] Request counter (via bus)1 = Trigger1 Bit1.17 triggerCW
97[In3] Info switch (via bus)1 = On, 0 = Off1 Bit1.1 switchCW
97[In3] Over-Heating Output1 = Over-Heating, 0 = No Over-Heating1 Bit1.5 alarmCT
98[In3] Over-Cooling Output1 = Over-Cooling, 0 = No Over-Cooling1 Bit1.5 alarmCT
98[In3] Counter 16 BitsCounter (0-65535)2 Bytes7.1 pulsesCT
98[In3] Info switch Long (via bus)1 = On, 0 = Off1 Bit1.1 switchCW
98[In3] Switch 41 = On, 0 = Off1 Bit1.1 switchCT
98[In3] Counter 8 BitsCounter (0-255)1 Byte5.10 counter pulses (0..255)CT
98[In3] Counter 32 BitsCounter (0-4.294.967.295)4 Bytes13.1 counter pulses (signed)CT
99[In3] Switch 51 = On, 0 = Off1 Bit1.1 switchCT
100[In3] Scene save0 = Scene 1, 1 = Scene 21 Bit1.3 enableCT
100[In3] Increase/Decrease (via bus)0 = Up, 1 = Down1 Bit1.8 up/downCW
101[In4] Disable Temperature functionality (via bus)1 = Disable, 0 = Enable1 Bit1.3 enableCW
101[In4] Disable channel (via bus)1 = Disable, 0 = Enable1 Bit1.3 enableCW
102[In4] Switch1 = On, 0 = Off1 Bit1.1 switchCT
102[In4] Scene control 8 BitsScene control1 Byte18.1 scene controlCT
102[In4] Temperature value OutputTemperature value2 Bytes9.1 temperature (°C)CT
102[In4] 2 Bits value after operation2 Bits value2 Bit2.1 switch controlCT
102[In4] 4 Bytes value after operation4 Bytes value4 Bytes12.1 counter pulses (unsigned)CT
102[In4] Counter direction (via bus)0 = Up, 1 = Down1 Bit1.8 up/downCW
102[In4] Scene 1 Bit0 = Scene 1, 1 = Scene 21 Bit1.11 stateCT
102[In4] 2 Bytes floating value after operation2 Bytes floating value2 Bytes9.1 temperature (°C)CT
102[In4] Byte value after operationByte value1 Byte5.10 counter pulses (0..255)CT
102[In4] 2 Bytes value after operation2 Bytes value2 Bytes7.1 pulsesCT
102[In4] Stop / Step0 = Step Up, 1 = Step Down1 Bit1.7 stepCT
102[In4] Bit value after operationBit value1 Bit1.11 stateCT
102[In4] 2 Bytes signed value after operation2 Bytes signed value2 Bytes8.1 pulses differenceCT
102[In4] RGB Colour value outputRGB colour3 Bytes232.600 RGB value 3x(0..255)CT
103[In4] 2 Bits value after Long operation2 Bits value2 Bit2.1 switch controlCT
103[In4] Reset Counter (via bus)0 = No action, 1 = Reset1 Bit1.15 resetCW
103[In4] Scene save0 = No action, 1 = Save Scene1 Bit1.3 enableCW
103[In4] Switch Long1 = On, 0 = Off1 Bit1.1 switchCT
103[In4] DimmingDimming4 Bit3.7 dimming controlCT
103[In4] 2 Bytes value after Long operation2 Bytes value2 Bytes7.1 pulsesCT
103[In4] Byte value after Long operationByte value1 Byte5.10 counter pulses (0..255)CT
103[In4] Sensor not connected Output0 = Sensor Ok, 1 = Sensor not connected1 Bit1.11 stateCT
103[In4] Switch 21 = On, 0 = Off1 Bit1.1 switchCT
103[In4] Bit value after Long operationBit value1 Bit1.11 stateCT
103[In4] 2 Bytes signed value after Long operation2 Bytes signed value2 Bytes8.1 pulses differenceCT
103[In4] 2 Bytes floating value after Long operation2 Bytes floating value2 Bytes9.1 temperature (°C)CT
103[In4] 4 Bytes value after Long operation4 Bytes value4 Bytes12.1 counter pulses (unsigned)CT
103[In4] Move0 = Up, 1 = Down1 Bit1.8 up/downCT
104[In4] Over-Heating Output1 = Over-Heating, 0 = No Over-Heating1 Bit1.5 alarmCT
104[In4] Request Counter (via bus)1 = Trigger1 Bit1.17 triggerCW
104[In4] Switch 31 = On, 0 = Off1 Bit1.1 switchCT
104[In4] Info Switch (via bus)1 = On, 0 = Off1 Bit1.1 switchCW
105[In4] Switch 41 = On, 0 = Off1 Bit1.1 switchCT
105[In4] Counter 32 bitsCounter (0-4.294.967.295)4 Bytes13.1 counter pulses (signed)CT
105[In4] Over-Cooling Output1 = Over-Cooling, 0 = No Over-Cooling1 Bit1.5 alarmCT
105[In4] Counter 8 BitsCounter (0-255)1 Byte5.10 counter pulses (0..255)CT
105[In4] Counter 16 BitsCounter (0-65535)2 Bytes7.1 pulsesCT
105[In4] Info Switch Long (via bus)1 = On, 0 = Off1 Bit1.1 switchCW
106[In4] Switch 51 = On, 0 = Off1 Bit1.1 switchCT
107[In4] Increase/Decrease (via bus)0 = Up, 1 = Down1 Bit1.8 up/downCW
107[In4] Scene save0 = Scene 1, 1 = Scene 21 Bit1.3 enableCT
115[T1] On/Off status Info1 = On; 0 = Off1 Bit1.1 switchCT
116[T1] On/Off Input1 = On; 0 = Off1 Bit1.1 switchCW
117[T1] Set-point InformationCurrent Set-point2 Bytes9.1 temperature (°C)CT
118[T1] Set-point InputSet-point2 Bytes9.1 temperature (°C)CW
118[T1] Comfort Set-point InputComfort Set-point2 Bytes9.1 temperature (°C)CW
119[T1] OutputOutput (PWM Proportional - Integral)1 Bit1.1 switchCT
119[T1] OutputOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CT
119[T1] Output HeatingOutput (2 points with Hysteresis)1 Bit1.1 switchCT
119[T1] Output HeatingOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CT
119[T1] OutputOutput (2 points with Hysteresis)1 Bit1.1 switchCT
119[T1] Output HeatingOutput (PWM Proportional - Integral)1 Bit1.1 switchCT
120[T1] Output CoolingOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CT
120[T1] Output CoolingOutput (PWM Proportional - Integral)1 Bit1.1 switchCT
120[T1] Output CoolingOutput (2 points with Hysteresis)1 Bit1.1 switchCT
121[T1] Temperature Sensor 1Input Temperature Sensor 12 Bytes9.1 temperature (°C)CW
122[T1] Temperature Sensor 2Input Temperature Sensor 22 Bytes9.1 temperature (°C)CW
123[T1] Special mode Info2 Bytes mode Info2 Bytes22.101 RHCC statusCT
124[T1] Special mode Input 1 Byte1 Byte mode HVAC1 Byte20.102 HVAC modeCW
125[T1] Special mode Economic0=Off; 1=On1 Bit1.1 switchCW
126[T1] Special mode Stand-by0=Off; 1=On1 Bit1.1 switchCW
127[T1] Special mode Protection0=Off; 1=On1 Bit1.1 switchCW
128[T1] Special mode Comfort0=Off; 1=On1 Bit1.1 switchCW
129[T1] Heating or Cooling mode Status0=Cooling; 1=Heating1 Bit1.100 cooling/heatingCT
130[T1] Heating or Cooling mode0=Cooling; 1=Heating1 Bit1.100 cooling/heatingCW
131[T1] Window alarm 1 Input0=No alarm; 1=Alarm1 Bit1.5 alarmCW
132[T1] Window alarm 2 Input0=No alarm; 1=Alarm1 Bit1.5 alarmCW
133[T1] Window alarm 3 Input0=No alarm; 1=Alarm1 Bit1.5 alarmCW
134[T1] Window alarm 4 Input0=No alarm; 1=Alarm1 Bit1.5 alarmCW
135[T2] On/Off status Info1 = On; 0 = Off1 Bit1.1 switchCT
136[T2] On/Off Input1 = On; 0 = Off1 Bit1.1 switchCW
137[T2] Set-point InformationCurrent Set-point2 Bytes9.1 temperature (°C)CT
138[T2] Comfort Set-point InputComfort Set-point2 Bytes9.1 temperature (°C)CW
138[T2] Set-point InputSet-point2 Bytes9.1 temperature (°C)CW
139[T2] Output HeatingOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CT
139[T2] OutputOutput (PWM Proportional - Integral)1 Bit1.1 switchCT
139[T2] Output HeatingOutput (PWM Proportional - Integral)1 Bit1.1 switchCT
139[T2] OutputOutput (2 points with Hysteresis)1 Bit1.1 switchCT
139[T2] Output HeatingOutput (2 points with Hysteresis)1 Bit1.1 switchCT
139[T2] OutputOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CT
140[T2] Output CoolingOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CT
140[T2] Output CoolingOutput (2 points with Hysteresis)1 Bit1.1 switchCT
140[T2] Output CoolingOutput (PWM Proportional - Integral)1 Bit1.1 switchCT
141[T2] Temperature sensor 1Input Temperature Sensor 12 Bytes9.1 temperature (°C)CW
142[T2] Temperature sensor 2Input Temperature Sensor 22 Bytes9.1 temperature (°C)CW
143[T2] Special mode Info2 Bytes mode Info2 Bytes22.101 RHCC statusCT
144[T2] Special mode Input 1 Byte1 Byte mode HVAC1 Byte20.102 HVAC modeCW
145[T2] Special mode Economic0=Off; 1=On1 Bit1.1 switchCW
146[T2] Special mode Stand-by0=Off; 1=On1 Bit1.1 switchCW
147[T2] Special mode Protection0=Off; 1=On1 Bit1.1 switchCW
148[T2] Special mode Comfort0=Off; 1=On1 Bit1.1 switchCW
149[T2] Heating or Cooling mode Status0=Cooling; 1=Heating1 Bit1.100 cooling/heatingCT
150[T2] Heating or Cooling mode0=Cooling; 1=Heating1 Bit1.100 cooling/heatingCW
151[T2] Window alarm 1 Input0=No alarm; 1=Alarm1 Bit1.5 alarmCW
152[T2] Window alarm 2 Input0=No alarm; 1=Alarm1 Bit1.5 alarmCW
153[T2] Window alarm 3 Input0=No alarm; 1=Alarm1 Bit1.5 alarmCW
154[T2] Window alarm 4 Input0=No alarm; 1=Alarm1 Bit1.5 alarmCW
155[T3] On/Off status Info1 = On; 0 = Off1 Bit1.1 switchCT
156[T3] On/Off Input1 = On; 0 = Off1 Bit1.1 switchCW
157[T3] Set-point InformationCurrent Set-point2 Bytes9.1 temperature (°C)CT
158[T3] Set-point InputSet-point2 Bytes9.1 temperature (°C)CW
158[T3] Comfort Set-point InputComfort Set-point2 Bytes9.1 temperature (°C)CW
159[T3] Output HeatingOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CT
159[T3] Output HeatingOutput (PWM Proportional - Integral)1 Bit1.1 switchCT
159[T3] OutputOutput (2 points with Hysteresis)1 Bit1.1 switchCT
159[T3] OutputOutput (PWM Proportional - Integral)1 Bit1.1 switchCT
159[T3] Output HeatingOutput (2 points with Hysteresis)1 Bit1.1 switchCT
159[T3] OutputOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CT
160[T3] Output CoolingOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CT
160[T3] Output CoolingOutput (2 points with Hysteresis)1 Bit1.1 switchCT
160[T3] Output CoolingOutput (PWM Proportional - Integral)1 Bit1.1 switchCT
161[T3] Temperature Sensor 1Input Temperature Sensor 12 Bytes9.1 temperature (°C)CW
162[T3] Temperature Sensor 2Input Temperature Sensor 22 Bytes9.1 temperature (°C)CW
163[T3] Special mode Info2 Bytes mode Info2 Bytes22.101 RHCC statusCT
164[T3] Special mode Input 1 Byte1 Byte mode HVAC1 Byte20.102 HVAC modeCW
165[T3] Special mode Economic0=Off; 1=On1 Bit1.1 switchCW
166[T3] Special mode Stand-by0=Off; 1=On1 Bit1.1 switchCW
167[T3] Special mode Protection0=Off; 1=On1 Bit1.1 switchCW
168[T3] Special mode Comfort0=Off; 1=On1 Bit1.1 switchCW
169[T3] Heating or Cooling mode Status0=Cooling; 1=Heating1 Bit1.100 cooling/heatingCT
170[T3] Heating or Cooling mode0=Cooling; 1=Heating1 Bit1.100 cooling/heatingCW
171[T3] Window alarm 1 Input0=No alarm; 1=Alarm1 Bit1.5 alarmCW
172[T3] Window alarm 2 Input0=No alarm; 1=Alarm1 Bit1.5 alarmCW
173[T3] Window alarm 3 Input0=No alarm; 1=Alarm1 Bit1.5 alarmCW
174[T3] Window alarm 4 Input0=No alarm; 1=Alarm1 Bit1.5 alarmCW
175[T4] On/Off status Info1 = On; 0 = Off1 Bit1.1 switchCT
176[T4] On/Off Input1 = On; 0 = Off1 Bit1.1 switchCW
177[T4] Set-point InformationCurrent Set-point2 Bytes9.1 temperature (°C)CT
178[T4] Comfort Set-point InputComfort Set-point2 Bytes9.1 temperature (°C)CW
178[T4] Set-point InputSet-point2 Bytes9.1 temperature (°C)CW
179[T4] OutputOutput (PWM Proportional - Integral)1 Bit1.1 switchCT
179[T4] Output HeatingOutput (2 points with Hysteresis)1 Bit1.1 switchCT
179[T4] Output HeatingOutput (PWM Proportional - Integral)1 Bit1.1 switchCT
179[T4] Output HeatingOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CT
179[T4] OutputOutput (2 points with Hysteresis)1 Bit1.1 switchCT
179[T4] OutputOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CT
180[T4] Output CoolingOutput (% Proportional - Integral)1 Byte5.1 percentage (0..100%)CT
180[T4] Output CoolingOutput (2 points with Hysteresis)1 Bit1.1 switchCT
180[T4] Output CoolingOutput (PWM Proportional - Integral)1 Bit1.1 switchCT
181[T4] Temperature Sensor 1Input Temperature Sensor 12 Bytes9.1 temperature (°C)CW
182[T4] Temperature Sensor 2Input Temperature Sensor 22 Bytes9.1 temperature (°C)CW
183[T4] Special mode Info2 Bytes mode Info2 Bytes22.101 RHCC statusCT
184[T4] Special mode Input 1 Byte1 Byte mode HVAC1 Byte20.102 HVAC modeCW
185[T4] Special mode Economic0=Off; 1=On1 Bit1.1 switchCW
186[T4] Special mode Stand-by0=Off; 1=On1 Bit1.1 switchCW
187[T4] Special mode Protection0=Off; 1=On1 Bit1.1 switchCW
188[T4] Special mode Comfort0=Off; 1=On1 Bit1.1 switchCW
189[T4] Heating or Cooling mode Status0=Cooling; 1=Heating1 Bit1.100 cooling/heatingCT
190[T4] Heating or Cooling mode0=Cooling; 1=Heating1 Bit1.100 cooling/heatingCW
191[T4] Window alarm 1 Input0=No alarm; 1=Alarm1 Bit1.5 alarmCW
192[T4] Window alarm 2 Input0=No alarm; 1=Alarm1 Bit1.5 alarmCW
193[T4] Window alarm 3 Input0=No alarm; 1=Alarm1 Bit1.5 alarmCW
194[T4] Window alarm 4 Input0=No alarm; 1=Alarm1 Bit1.5 alarmCW
Parameters (227)
ParameterTypeDefault
RASTRO_ETSunsignedInt 0…25516
PWM Frequencylist250 Hz
Operating modelist3-channel Dimmer
Enable Sequence 1unsignedInt 0…10
Enable Sequence 2unsignedInt 0…10
Enable Sequence 3unsignedInt 0…10
Enable Sequence 4unsignedInt 0…10
Enable Sequence 5unsignedInt 0…10
Timer time delay (Sec)list60
Pre-warning in Timer function (Sec)list0
Minimum Brightness (%)unsignedInt 0…1000
Maximum Brightness (%)unsignedInt 0…100100
Soft Turn-on time ( x 0,1 Sec)unsignedInt 1…655351
Soft Turn-off time ( x 0,1 Sec)unsignedInt 1…655353
Switch-on modelistSwitch-on at last turn-off brightness
Switch-on brightness value (%)unsignedInt 0…1003
Action after power supply recoverylistOff
Brightness after power supply recovery (%)unsignedInt 0…1000
Switch-on Ramp time (Sec)unsignedInt 1…655351
ON time (Seg)unsignedInt 1…655351
Switch-off Ramp time (Sec)unsignedInt 1…655351
OFF time (Sec)unsignedInt 1…655351
Number of Scenes attendedlistAll Scenes
Scene number 1listScene 1
Scene number 2listScene 2
Scene number 3listScene 3
Scene number 4listScene 4
Scene number 5listScene 5
Default Brightness (%) Scene 1unsignedInt 0…100100
Default Brightness (%) Scene 2unsignedInt 0…100100
Default Brightness (%) Scene 3unsignedInt 0…100100
Default Brightness (%) Scene 4unsignedInt 0…100100
Default Brightness (%) Scene 5unsignedInt 0…100100
Dimming speed (from 0% to 100% x 0,1Sec)unsignedInt 1…6553550
Behavior on incoming Dimming ValuelistGo directly
OFF state brightness (%)unsignedInt 0…1000
CH0_EMPTY_1unsignedInt 0…2550
CH0_EMPTY_2unsignedInt 0…2550
CH0_EMPTY_3unsignedInt 0…2550
CH0_EMPTY_4unsignedInt 0…2550
CH0_EMPTY_5unsignedInt 0…2550
CH0_EMPTY_6unsignedInt 0…655350
CH0_EMPTY_7unsignedInt 0…655350
CH0_EMPTY_8unsignedInt 0…655350
Switch-on brightness value (%)unsignedInt 0…1000
CH1_EMPTY_1unsignedInt 0…2550
CH1_EMPTY_2unsignedInt 0…2550
CH1_EMPTY_3unsignedInt 0…2550
CH1_EMPTY_4unsignedInt 0…2550
CH1_EMPTY_5unsignedInt 0…2550
CH1_EMPTY_6unsignedInt 0…655350
CH1_EMPTY_7unsignedInt 0…655350
CH1_EMPTY_8unsignedInt 0…655350
Brightness after power supply recovery (%)unsignedInt 0…1003
CH2_EMPTY_1unsignedInt 0…2550
CH2_EMPTY_2unsignedInt 0…2550
CH2_EMPTY_3unsignedInt 0…2550
CH2_EMPTY_4unsignedInt 0…2550
CH2_EMPTY_5unsignedInt 0…2550
CH2_EMPTY_6unsignedInt 0…655350
CH2_EMPTY_7unsignedInt 0…655350
CH2_EMPTY_8unsignedInt 0…655350
RED:unsignedInt 0…1003
GREEN:unsignedInt 0…1003
BLUE:unsignedInt 0…1003
RED:unsignedInt 0…100100
GREEN:unsignedInt 0…100100
BLUE:unsignedInt 0…100100
Scene number (1-64)listScene 1
Sequence number (1-5)listSequence 1
Dimming speed (from 0% to 100% x 0,1Sec)unsignedInt 1…486450
RGB_DIRECT_LIGHT_MODEunsignedInt 0…2550
RED:unsignedInt 0…1000
GREEN:unsignedInt 0…1000
BLUE:unsignedInt 0…1000
RGB_RELATIVE_IND_CTRL_ENABLEunsignedInt 0…2550
RGB_ABSOLTE_IND_CTRL_ENABLEunsignedInt 0…2550
RGB_SW_ENABLE_RELATIVE_DIMunsignedInt 0…2550
RGB_SW_ENABLE_ABSOLUTE_DIMunsignedInt 0…2550
RGB_COLORRGB_OFF_VALUE_BYTE_REDunsignedInt 0…2550
RGB_COLORRGB_OFF_VALUE_BYTE_GREENunsignedInt 0…2550
RGB_COLORRGB_OFF_VALUE_BYTE_BLUEunsignedInt 0…2550
RGB_REL_DIM_OFF_VALUE_BYTE_REDunsignedInt 0…2550
RGB_REL_DIM_OFF_VALUE_BYTE_GREENunsignedInt 0…2550
RGB_REL_DIM_OFF_VALUE_BYTE_BLUEunsignedInt 0…2550
RGB_ABS_DIM_OFF_VALUE_BYTE_REDunsignedInt 0…2550
RGB_ABS_DIM_OFF_VALUE_BYTE_GREENunsignedInt 0…2550
RGB_ABS_DIM_OFF_VALUE_BYTE_BLUEunsignedInt 0…2550
RGB_EMPTY_1unsignedInt 0…2550
RGB_EMPTY_2unsignedInt 0…2550
RGB_EMPTY_3unsignedInt 0…2550
RGB_EMPTY_4unsignedInt 0…2550
RGB_EMPTY_5unsignedInt 0…2550
RGB_EMPTY_6unsignedInt 0…2550
RGB_EMPTY_7unsignedInt 0…2550
RGB_EMPTY_8unsignedInt 0…2550
RGB_EMPTY_9unsignedInt 0…2550
RGB_EMPTY_10unsignedInt 0…2550
RGB_EMPTY_11unsignedInt 0…655350
RGB_EMPTY_12unsignedInt 0…655350
RGB_EMPTY_13unsignedInt 0…655350
Do this SequencelistOnce
Number of StepslistOne Step
Step time (x 0,1 Sec)unsignedInt 1…65535100
Function of channel 1listDimmer
Debounce timelist10 mSec
Distinction between Short and Long actionunsignedInt 0…10
Contact typelistNormally Open
Long action after...list0,3 Sec
Number of objects for Short/Long operationlist1
Short actionlistToggle
Long actionlistOn
Cyclic transmissionlistNo
Action after Closing contactlistToggle
Action after Opening contactlistNone
Transmit state after bus voltage recoveryunsignedInt 0…10
Action after Closing contactlistOn
Action after Opening contactlistOn
Cycle base timelist1 Sec
Factor (Total time = Base x Factor)unsignedInt 0…2557
Dimming functionalitylistDimming and Switch
Action after operationlistBrighter / Darker
Action after Long operationlistBrighter / Darker
Save Scene after Long operationunsignedInt 0…10
Maximum time between two operationslist0,5 Sec
Number of operationslist2
Switch 1 operationlistOn
Switch 2 operationlistOn
Switch 3 operationlistOn
Switch 4 operationlistOn
Number of objectslist2
Functional constructionlist1 Pushbutton
Shutter functionalitylistShort = Step, Long = Move
Action after Long operationlistMove Up
Action after Short operationlistStep Down
Value type after Short operationlist1 Bit
Value type after Long operationlist1 Bit
Signlist+
Integer partunsignedInt 0…990
Decimal partunsignedInt 0…990
2 Bytes valueunsignedInt 0…655350
2 Bytes signed valuesignedInt -32768…327670
4 Bytes valueunsignedInt 0…42949672950
Bit valuelist0
2 Bits valuelist"00"
1 Byte valueunsignedInt 0…2550
Value type after operationlist1 Bit
Type of Scene controllist8 Bits Scene
Scene numberunsignedInt 1…641
Action after Short operationlistCall
Save ScenelistNo
Scene number 1/2unsignedInt 1…21
Data counter widthlist8
Start value (0-255)unsignedInt 0…2550
Start value (0-65535)unsignedInt 0…655350
Start value (0-4.294.967.295)unsignedInt 0…42949672950
Temperature value base timelist1 Min
Temperature variation to sendunsignedInt 5…2005
Protection alarmslistNo protections
HysteresisunsignedInt 0…500
Over-Heating temperaturelist-30
Over-Cooling temperaturelist-30
"Temperature functionality" enabled after bus recovery voltageunsignedInt 0…10
Temperature sensor calibration valuelist0
Function of channel 2listDimmer
Over-Heating Temperaturelist-30
Over-Cooling Temperaturelist-30
Temperature Sensor calibration valuelist0
Function of channel 3listDimmer
Function of channel 4listDimmer
2 Bits valuelistOn
Enable Thermostat 1unsignedInt 0…10
ModelistCooling Thermostat
Reference Temperature SourcelistOne source
Thermostat always onunsignedInt 0…10
State after bus recovery voltagelistOff
Enable turn-on Thermostat when Special command arrivesunsignedInt 0…10
Send Thermostat Set-point after bus recovery voltageunsignedInt 0…10
Enable automatic mode changeunsignedInt 0…10
Mode after bus recovery voltagelistCooling Thermostat
Control objectlistDifferent objects for heating and cooling
Set-point modelistAbsolute Set-point mode
Initial Comfort Set-point after bus recovery voltageunsignedInt 5…4524
Save Set-point after mode change via objectunsignedInt 0…10
Mode after bus recovery voltagelistComfort
Enable 1 Bit mode objectslistDisable
Enable Window protectionunsignedInt 0…10
Comfort mode Set-pointunsignedInt 5…4522
Offset for Stand-by Set-point modelist-40
Offset for Economic Set-point modelist-60
Set-point for protection from FreezingunsignedInt 0…158
Comfort mode Set-pointunsignedInt 5…4524
Offset for Stand-by Set-point modeunsignedInt 0…9940
Offset for Economic Set-point modeunsignedInt 0…9960
Over-temperature protection Set-pointunsignedInt 30…4540
Regulation modelist2-point with Hysteresis control
Upper HysteresisunsignedInt 5…4510
Lower HysteresisunsignedInt 5…4510
Forwarding period (0=Disable)unsignedInt 0…2550
PWM typelistPWM (1 Bit)
PI cycle timeunsignedInt 0…25515
Proportional bandunsignedInt 0…155
Attenuation factorunsignedInt 0…9931
Maximum Integral component (%)unsignedInt 0…995
Enable Thermostat 2unsignedInt 0…10
Initial Set-point after bus recovery voltageunsignedInt 5…4524
Over-Temperature protection Set-pointunsignedInt 30…4540
Enable Thermostat 3unsignedInt 0…10
Enable Thermostat 4unsignedInt 0…10
Factor time to send temperature (Total time = Base x Factor) (0=Disable send)unsignedInt 0…2557
Action after operationlistMove Up
Save Offset after mode change via objectunsignedInt 0…10
Number of colours to togglelist7 colours
Add black colour (switch off)unsignedInt 0…10
Color brightness value (%)unsignedInt 0…100100
Enable Timer FunctionunsignedInt 0…10
Enable Dimming Speed objectunsignedInt 0…10
Enable Forced objectunsignedInt 0…10
Enable Scenes FunctionunsignedInt 0…10
Enable Absolute DimmingunsignedInt 0…10
Enable Color objectunsignedInt 0…10
Enable Overload Alarm objectunsignedInt 0…10
Enable Sequences FunctionsunsignedInt 0…10
Enable Relative Individual Dimming objectsunsignedInt 0…10
Enable Channel Disable objectunsignedInt 0…10
Enable Temperature Disable objectunsignedInt 0…10
Enable Sensor Not Connected objectunsignedInt 0…10

Version history

ApplicationApp noFingerprintFirst seenSizeFile
DINUY_REK5XRGB 0.0 latest$20077CBC2026-11-25225 KBDownload

About this file

This is the official ETS product database for the Dinuy DINUY RF 3-channel LED Strip Dimmer_4input ch (RE K5X RGB), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Dinuy