KNX-305-IN 025672
Arlight · Order number 025672 · KNX-305-IN › KNX-305-IN
KNX-305-IN
Download .knxprod KNX Motion&Brightness sensor 1.0 · 71 KB
Product
| Manufacturer | Arlight |
|---|---|
| Product name | KNX-305-IN |
| Order number | 025672 |
| Hardware | KNX-305-IN |
| Medium | Twisted Pair |
| Rail mounted | No |
| Registration | Certified |
| Languages | en-US |
| Catalog entry | M-01C4_H-0EXXXX-16-O0085_HP-0108-10-488A-O0085_CI-025672-16 |
| Fingerprint | 488A |
| SHA-256 | 30a776780a603ed1a04a2e979216321723dce3f2b7b8ef8904d63b206a2b9002 |
| First seen | 2026-11-25 |
| Markets | Belarus, Kazakhstan, Russia |
Application program: KNX Motion&Brightness sensor 1.0
| Application number | $0108 |
|---|---|
| Version | 1.0 |
| Mask version | MV-0705 (7.5) |
| KNX Data Secure | No |
| Parameters | 93 |
| Group objects | 22 |
Group objects (22)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Slave value | Slave value in | 1 Bit | 1.1 switch | CW |
| 1 | Master send 1bit | Master send 1bit | 1 Bit | 1.1 switch | CT |
| 2 | Master send 4bit | Master send 4bit | 4 Bit | 3.7 dimming control | CT |
| 3 | Master send 1byte | Master send 1byte | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 4 | Cyclically send lux value | Cyclically send lux value | 2 Bytes | CRT | |
| 4 | Read lux value | Read lux value | 2 Bytes | CRT | |
| 5 | change threshold Lower | Change threshold lower | 2 Bytes | CW | |
| 6 | change threshold Upper | Change threshold upper | 2 Bytes | CW | |
| 7 | Change sensitivity | Change sensitivity | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 8 | Illumination send 1 bit | Illumination send 1 bit | 1 Bit | 1.1 switch | CT |
| 9 | Illumination send 4 bit | Illumination send 4 bit | 4 Bit | 3.7 dimming control | CT |
| 10 | Illumination send 1 byte | Illumination send 1 byte | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 11 | Movement send 1bit | Movement send 1bit | 1 Bit | 1.1 switch | CT |
| 12 | Movement send 4bit | Movement send 4bit | 4 Bit | 3.7 dimming control | CT |
| 13 | Movement send 1byte | Movement send 1byte | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 14 | Logic result send 1bit | Result logic send 1bit | 1 Bit | 1.1 switch | CT |
| 15 | Logic result send 4bit | Result logic send 4bit | 4 Bit | 3.7 dimming control | CT |
| 16 | Logic result send 1byte | Result logic send 1byte | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 17 | input 0 of logic | input 0 of logic | 1 Bit | 1.1 switch | CW |
| 18 | Disable Lux Function | Disable Lux Function | 1 Bit | 1.3 enable | CW |
| 19 | Disable Movement Function | Disable Movement Function | 1 Bit | 1.3 enable | CW |
| 20 | Disable Logic Function | Disable Logic Function | 1 Bit | 1.3 enable | CW |
Parameters (51)
| Parameter | Type | Default |
|---|---|---|
| System delay time after votage recovery | text | Fix time 40s, to stabilize the device |
| The device type is | list | Standard/Slave |
| Illumination Value 1bit/4bit/1byte obejct send | list | enable |
| Movement Value 1bit/4bit/1byte obejct send | list | enable |
| Threshold 1 value[Lower threshold] | unsignedInt 0…65535 | 70 |
| Threshold 2 value[Upper threshold] Must Upper than Lower threshold | unsignedInt 0…65535 | 250 |
| Respond mode of the brightness | list | none |
| Interval time of cyclical response: Base | list | 1s |
| Factor[1..255] | unsignedInt 1…255 | 10 |
| Threshold can be changed via bus | list | disable |
| Threshold behaviour | list | with hysteresis |
| Interval time of value cyclic.send: Base | list | 1s |
| Factor[1...255] | unsignedInt 1…255 | 10 |
| Send Illumination Teleg. on bus recovery | list | YES |
| If Lux<=Lower, value send mode | list | no send |
| If Lux<=Lower logic 1bit [0..1] | list | '0' |
| 4bit [0..15] | unsignedInt 0…15 | 1 |
| 1byte [0..255] | unsignedInt 0…255 | 128 |
| If Lower<Lux<Upper, value send mode | list | no send |
| logic 1 bit [0..1] | list | '0' |
| 4 bit [0..15] | unsignedInt 0…15 | 1 |
| 1 byte [0..255] | unsignedInt 0…255 | 128 |
| Lux="Current Brightness value" Lower="Lux Lower threshold" | text | <-----Attention |
| Upper="Lux Upper threshold" | text | <-----Attention |
| If Lux>=Upper, value send mode | list | no send |
| If Lux>=Upper logic 1bit [0..1] | list | '0' |
| Set the sensitivity of movement sensor [1......10] | unsignedInt 1…10 | 5 |
| Sensitivity can be changed via bus | list | disable |
| Function of movement retrigger | list | disable |
| Delay time of movement: Base | list | 1s |
| If Movement start, value send mode | list | no send |
| If Movement start logic 1 bit [0..1] | list | '0' |
| If Movement over, value send mode | list | no send |
| If Movement over logic 1 bit [0..1] | list | '0' |
| input 1:logic 1bit of illumination value input 2:logic 1bit of movement value | text | <-----Attention |
| Input 0 of logic is | list | disable |
| Object value of input 0 for logic after bus voltage recovery | list | "0" |
| The logic function type between input 1 and input 2 | list | AND |
| The logic function type between input 0 and result of input 1/2 | list | AND |
| Logic value cyclical send time: Base | list | 1s |
| If logic result ='0', value send mode | list | no send |
| Logic 1 bit [0..1] | list | '0' |
| If logic result ='1', value send mode | list | no send |
| Master value as a slave, logic 1bit: | list | illumination |
| Master delay start when | list | object "slave value" receive '1' |
| Master Delay time: Base | list | 1s |
| The master Delay start when receive specified value | text | <-----Attention |
| If the master receive the value again on delay time,Delay time will be reset. | text | <-----Attention |
| When delay start , send mode | list | Send one time |
| 1 bit [0..1] | list | '0' |
| When delay over , send mode | list | Send one time |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| KNX Motion&Brightness sensor 1.0 latest | $0108 | 488A | 2026-11-25 | 71 KB | Download |
About this file
This is the official ETS product database for the Arlight KNX-305-IN (025672), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from Arlight
- KNX-104-DIM-DIN 023041
- KNX-204-DIM-DIN 023042
- KNX-902-PS640-DIN 025542
- KNX-704-SW16-DIN/KNX-704-SW20-DIN 025661
- KNX-712-SW16-DIN 025662
- KNX-724-SW10-DIN 025664
- KNX-708-SW10-DIN 025665
- KNX-113-35-IN 025670
- KNX-704-BLIND-DIN 025671
- KNX-309-4DRY-DIN 025675
- KNX-304-ETH-DIN 025676
- KNX-309-4DRY-IN 025679