Arlight 025665 KNX-708-SW10-DIN

KNX-708-SW10-DIN 025665

Arlight · Order number 025665 · Actuator › Switch

KNX-708-SW10-DIN

Download .knxprod KNX Switch actuator 8ch 1.0 · 126 KB

Product

ManufacturerArlight
Product nameKNX-708-SW10-DIN
Order number025665
HardwareKNX-708-SW10-DIN
MediumTwisted Pair
Bus current (mA)12
Rail mountedYes
RegistrationCertified
Languagesen-US
Catalog entryM-01C4_H-0RXXXX-16-O0085_HP-0208-10-1AAC-O0085_CI-025665-16
Fingerprint1AAC
SHA-2567deb02936c72e641e2ac68aef415b95a618803c9423d5a056d38733db5e41347
First seen2026-11-25
MarketsBelarus, Kazakhstan, Russia

Application program: KNX Switch actuator 8ch 1.0

Application number$0208
Version1.0
Mask versionMV-0705 (7.5)
KNX Data SecureNo
Parameters901
Group objects203
Group objects (203)
NoNameFunctionSizeDPTFlags
0GeneralIn operation1 Bit1.2 booleanCRT
1Generalsafety priority 11 BitCWU
2Generalsafety priority 21 BitCWU
3Output Areply the switch status, A1 Bit1.1 switchCRT
3Output Asend the switch status, A1 Bit1.1 switchCRT
3Output AReply status of contact , A1 Bit1.1 switchCRT
4Output ASwitch, A1 Bit1.1 switchCW
4Output Aon-off of regulating , A1 Bit1.1 switchCW
5Output ASwitch out with delay, A1 Bit1.1 switchCW
5Output ASwitch out with flashing, A1 Bit1.10 start/stopCW
5Output AOutput of staircase lighting,A1 Bit1.10 start/stopCW
5Output AStatus (continuous),1 bit , A1 Bit1.1 switchCRT
6Output ASwitch time function, A1 Bit1.3 enableCW
7Output AWarning of staircase , A1 BitCRT
7Output Areport fault, regulating , A1 BitCRT
8Output ADuration of staircase , A2 Bytes7.1 pulsesCRW
9Output ACall preset 1/2 , A1 BitCW
10Output AStore preset 1/2, A1 BitCW
10Output ATrigger switch regularly , A1 BitCW
11Output AInput 1 of logic , A1 Bit1.1 switchCW
12Output AInput 2 of logic , A1 Bit1.1 switchCW
13Output AScene handle, A1 ByteCW
13Output AStatus (continuous),1 byte, A1 Byte5.1 percentage (0..100%)CRT
14Output AChange threshold 1, A1 Byte5.10 counter pulses (0..255)CW
14Output Acontinuous of regulating , A1 Byte5.1 percentage (0..100%)CW
15Output AThreshold input , A1 Byte5.10 counter pulses (0..255)CW
16Output AForced output , A1 BitCW
16Output Aforced operation,regulating, A1 BitCW
17Output Breply the switch status, B1 Bit1.1 switchCRT
17Output Bsend the switch status, B1 Bit1.1 switchCRT
17Output BReply status of contact , B1 Bit1.1 switchCRT
18Output BSwitch, B1 Bit1.1 switchCW
18Output Bon-off of regulating , B1 Bit1.1 switchCW
19Output BSwitch out with delay, B1 Bit1.1 switchCW
19Output BOutput of staircase lighting,B1 Bit1.10 start/stopCW
19Output BSwitch out with flashing, B1 Bit1.10 start/stopCW
19Output BStatus (continuous),1 bit , B1 Bit1.1 switchCRT
20Output BSwitch time function, B1 Bit1.3 enableCW
21Output BWarning of staircase , B1 BitCRT
21Output Breport fault, regulating , B1 BitCRT
22Output BDuration of staircase , B2 Bytes7.1 pulsesCRW
23Output BCall preset 1/2 , B1 BitCW
24Output BStore preset 1/2, B1 BitCW
24Output BTrigger switch regularly , B1 BitCW
25Output BInput 1 of logic , B1 Bit1.1 switchCW
26Output BInput 2 of logic , B1 Bit1.1 switchCW
27Output BScene handle, B1 ByteCW
27Output BStatus (continuous),1 byte, B1 Byte5.1 percentage (0..100%)CRT
28Output BChange threshold 1, B1 Byte5.10 counter pulses (0..255)CW
28Output Bcontinuous of regulating , B1 Byte5.1 percentage (0..100%)CW
29Output BThreshold input , B1 Byte5.10 counter pulses (0..255)CW
30Output BForced output , B1 BitCW
30Output Bforced operation,regulating, B1 BitCW
31Output Creply the switch status, C1 Bit1.1 switchCRT
31Output Csend the switch status, C1 Bit1.1 switchCRT
31Output CReply status of contact , C1 Bit1.1 switchCRT
32Output CSwitch, C1 Bit1.1 switchCW
32Output Con-off of regulating , C1 Bit1.1 switchCW
33Output CSwitch out with delay, C1 Bit1.1 switchCW
33Output COutput of staircase lighting,C1 Bit1.10 start/stopCW
33Output CSwitch out with flashing, C1 Bit1.10 start/stopCW
33Output CStatus (continuous),1 bit , C1 Bit1.1 switchCRT
34Output CSwitch time function, C1 Bit1.3 enableCW
35Output CWarning of staircase , C1 BitCRT
35Output Creport fault, regulating , C1 BitCRT
36Output CDuration of staircase , C2 Bytes7.1 pulsesCRW
37Output CCall preset 1/2 , C1 BitCW
38Output CStore preset 1/2, C1 BitCW
38Output CTrigger switch regularly , C1 BitCW
39Output CInput 1 of logic , C1 Bit1.1 switchCW
40Output CInput 2 of logic , C1 Bit1.1 switchCW
41Output CScene handle, C1 ByteCW
41Output CStatus (continuous),1 byte, C1 Byte5.1 percentage (0..100%)CRT
42Output CChange threshold 1, C1 Byte5.10 counter pulses (0..255)CW
42Output Ccontinuous of regulating , C1 Byte5.1 percentage (0..100%)CW
43Output CThreshold input , C1 Byte5.10 counter pulses (0..255)CW
44Output CForced output , C1 BitCW
44Output Cforced operation,regulating, C1 BitCW
45Output Dreply the switch status, D1 Bit1.1 switchCRT
45Output Dsend the switch status, D1 Bit1.1 switchCRT
45Output DReply status of contact , D1 Bit1.1 switchCRT
46Output DSwitch, D1 Bit1.1 switchCW
46Output Don-off of regulating , D1 Bit1.1 switchCW
47Output DSwitch out with delay, D1 Bit1.1 switchCW
47Output DOutput of staircase lighting,D1 Bit1.10 start/stopCW
47Output DSwitch out with flashing, D1 Bit1.10 start/stopCW
47Output DStatus (continuous),1 bit , D1 Bit1.1 switchCRT
48Output DSwitch time function, D1 Bit1.3 enableCW
49Output DWarning of staircase , D1 BitCRT
49Output Dreport fault, regulating , D1 BitCRT
50Output DDuration of staircase , D2 Bytes7.1 pulsesCRW
51Output DCall preset 1/2 , D1 BitCW
52Output DStore preset 1/2, D1 BitCW
52Output DTrigger switch regularly , D1 BitCW
53Output DInput 1 of logic , D1 Bit1.1 switchCW
54Output DInput 2 of logic , D1 Bit1.1 switchCW
55Output DScene handle, D1 ByteCW
55Output DStatus (continuous),1 byte, D1 Byte5.1 percentage (0..100%)CRT
56Output DChange threshold 1, D1 Byte5.10 counter pulses (0..255)CW
56Output Dcontinuous of regulating , D1 Byte5.1 percentage (0..100%)CW
57Output DThreshold input , D1 Byte5.10 counter pulses (0..255)CW
58Output DForced output , D1 BitCW
58Output Dforced operation,regulating, D1 BitCW
59Output Ereply the switch status, E1 Bit1.1 switchCRT
59Output Esend the switch status, E1 Bit1.1 switchCRT
59Output EReply status of contact , E1 Bit1.1 switchCRT
60Output ESwitch, E1 Bit1.1 switchCW
60Output Eon-off of regulating , E1 Bit1.1 switchCW
61Output ESwitch out with delay, E1 Bit1.1 switchCW
61Output EOutput of staircase lighting,E1 Bit1.10 start/stopCW
61Output ESwitch out with flashing, E1 Bit1.10 start/stopCW
61Output EStatus (continuous),1 bit , E1 Bit1.1 switchCRT
62Output ESwitch time function, E1 Bit1.3 enableCW
63Output EWarning of staircase , E1 BitCRT
63Output Ereport fault, regulating , E1 BitCRT
64Output EDuration of staircase , D2 Bytes7.1 pulsesCRW
65Output ECall preset 1/2 , E1 BitCW
66Output EStore preset 1/2, E1 BitCW
66Output ETrigger switch regularly , E1 BitCW
67Output EInput 1 of logic , E1 Bit1.1 switchCW
68Output EInput 2 of logic , E1 Bit1.1 switchCW
69Output EScene handle, E1 ByteCW
69Output EStatus (continuous),1 byte, E1 Byte5.1 percentage (0..100%)CRT
70Output EChange threshold 1, E1 Byte5.10 counter pulses (0..255)CW
70Output Econtinuous of regulating , E1 Byte5.1 percentage (0..100%)CW
71Output EThreshold input , E1 Byte5.10 counter pulses (0..255)CW
72Output EForced output , E1 BitCW
72Output Eforced operation,regulating, E1 BitCW
73Output Freply the switch status, F1 Bit1.1 switchCRT
73Output Fsend the switch status, F1 Bit1.1 switchCRT
73Output FReply status of contact , F1 Bit1.1 switchCRT
74Output FSwitch, F1 Bit1.1 switchCW
74Output Fon-off of regulating , F1 Bit1.1 switchCW
75Output FSwitch out with delay, F1 Bit1.1 switchCW
75Output FOutput of staircase lighting,F1 Bit1.10 start/stopCW
75Output FSwitch out with flashing, F1 Bit1.10 start/stopCW
75Output FStatus (continuous),1 bit , F1 Bit1.1 switchCRT
76Output FSwitch time function, F1 Bit1.3 enableCW
77Output FWarning of staircase , F1 BitCRT
77Output Freport fault, regulating , F1 BitCRT
78Output FDuration of staircase , F2 Bytes7.1 pulsesCRW
79Output FCall preset 1/2 , F1 BitCW
80Output FStore preset 1/2, F1 BitCW
80Output FTrigger switch regularly , F1 BitCW
81Output FInput 1 of logic , F1 Bit1.1 switchCW
82Output FInput 2 of logic , F1 Bit1.1 switchCW
83Output FScene handle, F1 ByteCW
83Output FStatus (continuous),1 byte, F1 Byte5.1 percentage (0..100%)CRT
84Output FChange threshold 1, F1 Byte5.10 counter pulses (0..255)CW
84Output Fcontinuous of regulating , F1 Byte5.1 percentage (0..100%)CW
85Output FThreshold input , F1 Byte5.10 counter pulses (0..255)CW
86Output FForced output , F1 BitCW
86Output Fforced operation,regulating, F1 BitCW
87Output Greply the switch status, G1 Bit1.1 switchCRT
87Output Gsend the switch status, G1 Bit1.1 switchCRT
87Output GReply status of contact , G1 Bit1.1 switchCRT
88Output GSwitch, G1 Bit1.1 switchCW
88Output Gon-off of regulating , G1 Bit1.1 switchCW
89Output GSwitch out with delay, G1 Bit1.1 switchCW
89Output GOutput of staircase lighting,G1 Bit1.10 start/stopCW
89Output GSwitch out with flashing, G1 Bit1.10 start/stopCW
89Output GStatus (continuous),1 bit , G1 Bit1.1 switchCRT
90Output GSwitch time function, G1 Bit1.3 enableCW
91Output GWarning of staircase , G1 BitCRT
91Output Greport fault, regulating , G1 BitCRT
92Output GDuration of staircase , G2 Bytes7.1 pulsesCRW
93Output GCall preset 1/2 , G1 BitCW
94Output GStore preset 1/2, G1 BitCW
94Output GTrigger switch regularly , G1 BitCW
95Output GInput 1 of logic , G1 Bit1.1 switchCW
96Output GInput 2 of logic , G1 Bit1.1 switchCW
97Output GScene handle, G1 ByteCW
97Output GStatus (continuous),1 byte, G1 Byte5.1 percentage (0..100%)CRT
98Output GChange threshold 1, G1 Byte5.10 counter pulses (0..255)CW
98Output Gcontinuous of regulating , G1 Byte5.1 percentage (0..100%)CW
99Output GThreshold input , G1 Byte5.10 counter pulses (0..255)CW
100Output GForced output , G1 BitCW
100Output Gforced operation,regulating, G1 BitCW
101Output Hreply the switch status, H1 Bit1.1 switchCRT
101Output Hsend the switch status, H1 Bit1.1 switchCRT
101Output HReply status of contact , H1 Bit1.1 switchCRT
102Output HSwitch, H1 Bit1.1 switchCW
102Output Hon-off of regulating , H1 Bit1.1 switchCW
103Output HSwitch out with delay, H1 Bit1.1 switchCW
103Output HOutput of staircase lighting,H1 Bit1.10 start/stopCW
103Output HSwitch out with flashing, H1 Bit1.10 start/stopCW
103Output HStatus (continuous),1 bit , H1 Bit1.1 switchCRT
104Output HSwitch time function, H1 Bit1.3 enableCW
105Output HWarning of staircase , H1 BitCRT
105Output Hreport fault, regulating , H1 BitCRT
106Output HDuration of staircase , H2 Bytes7.1 pulsesCRW
107Output HCall preset 1/2 , H1 BitCW
108Output HStore preset 1/2, H1 BitCW
108Output HTrigger switch regularly , H1 BitCW
109Output HInput 1 of logic , H1 Bit1.1 switchCW
110Output HInput 2 of logic , H1 Bit1.1 switchCW
111Output HScene handle, H1 ByteCW
111Output HStatus (continuous),1 byte, H1 Byte5.1 percentage (0..100%)CRT
112Output HChange threshold 1, H1 Byte5.10 counter pulses (0..255)CW
112Output Hcontinuous of regulating , H1 Byte5.1 percentage (0..100%)CW
113Output HThreshold input , H1 Byte5.10 counter pulses (0..255)CW
114Output HForced output , H1 BitCW
114Output Hforced operation,regulating, H1 BitCW
Parameters (85)
ParameterTypeDefault
Operation delay after recovery of bus voltage(1...250s)unsignedInt 1…2501
Sending cycle of In operation telegram (1......240s , 0=inactive)unsignedInt 0…2400
Enable safety priority functionlistdisable
---set safety priority 1:listinactive
Control period of safety priority 1 (1......240 s, 0=inactive)unsignedInt 0…2400
---set safety priority 2:listinactive
Control period of safety priority 2 (1......240 s, 0=inactive)unsignedInt 0…2400
=====N o t e===== Normal, object value map switch on/offlist1=switch on; 0=switch off
Work mode of the channellistSwitch actuator
If bus voltage recovery,contact islistunchange
If bus voltage fail,contact islistunchange
Object value of telegram switch after bus voltage recoverylistnot write
Set the reply mode of switch statuslistno reply
Object value of switch status :list0=contact open ; 1=contact close
Contact position if tele. value is 1 (0 is opposite of 1 if changed)listclose
Special functions of switch actuator modelistinactive
Function of time for switch islistdisable
Function of preset for switch islistdisable
Function of logic for switch islistdisable
Function of scene for switch islistdisable
Function of threshold for switch islistdisable
Function of safety for switch islistdisable
Function of forced for switch islistdisable
The mode of time functionlistdelay switch
Delay for switch on : --(0...240 minutes)unsignedInt 0…2400
--(0...59 seconds)unsignedInt 0…590
Delay for switch off : --(0...240 minutes)unsignedInt 0…2400
Number of ON-impulses (1...255 , 0=no limited)unsignedInt 0…2550
Contact position after flashinglistunchange
The mode of control for flashinglistStart with 1 , Stop with 0"
Duration of staircase lighting --(0...1000 minutes)unsignedInt 0…10002
The mode of control for staircase lighting islistStart with 0/1 , can not be stop
During the lighting time, if receive the Start telegram,listrestart duration of staircase lighting
Warning mode for ending of staircase lightinglistnothing
--The warning time for end of staircase lighting(0...59 s)unsignedInt 0…590
Modify the duration via object (0...60059 seconds)listdisable
Action for preset 1(object value=0)listNone
Action for preset 2(object value=1)listOFF
Setting for preset via telegram islistdisable
The input 0 (switch object) for logic islistdisable
The input 1 of logic islistdisable
Function type between input0 and input1listAND
Result is invertedlistNO
Value of input 1 after bus voltage recovery :list0"
The input 2 of logic islistdisable
Function type between input2 and input0/1listAND
Value of input 2 after bus voltage recovery :list0"
1> channel is assigned to (1...64 scene NO.,0= no allocation)unsignedInt 0…640
--Standard output value islistOFF
2> channel is assigned to (1...64 scene NO.,0= no allocation)unsignedInt 0…640
3> channel is assigned to (1...64 scene NO.,0= no allocation)unsignedInt 0…640
4> channel is assigned to (1...64 scene NO.,0= no allocation)unsignedInt 0…640
5> channel is assigned to (1...64 scene NO.,0= no allocation)unsignedInt 0…640
Threshold 1 valueunsignedInt 0…25580
Threshold 2 valueunsignedInt 0…255200
Change threshold 1via object :listdisable
Threshold behaviourlistwithout hysteresis
--If falling below lower threshold, contact positionlistunchange
--If exceeding upper threshold, contact positionlistunchange
--If lower < object value < upper contact positionlistunchange
Setting of safetyliston parameter-window General"
Contact position if safety priority 1listunchange
Contact position if safety priority 2listunchange
Contact position if forced operationlistunchange
If bus voltage fail ,contact islistunchange
If bus voltage recovery, the duty cycle of dynamic regulatelist0%(OFF)
PWM cycle time for continuous control (1...240 minutes)unsignedInt 0…2403
PWM cycle time for continuous control (0...59 secondsunsignedInt 0…590
Control telegram is received aslist1 bit ( on-off control )
Reply the status of channel for continuous controllistnothing
Reply the status of contact statelistnothing
Special functions of dynamic regulating actuator modelistinactive
Function for monitoring islistdisable
Function of forced operation islistdisable
Function of regular switch islistdisable
Function of safety operation islistdisable
Cyclic monitoring --in minutes (0...240 minutes)unsignedInt 0…24060
--in seconds (0...59 seconds)unsignedInt 0…590
The duty cycle of dynamic regulating during faultlistunchange
sending object report fault islistdisable
The duty cycle of dynamic regulating during forced operationlistunchange
Time of switch regular in minutes (0..255)unsignedInt 0…25510
Automatic switch regularlylistdisable
The duty cycle of dynamic regulating during safety 1 operationlistunchange
The duty cycle of dynamic regulating during safety 2 operationlistunchange

Version history

ApplicationApp noFingerprintFirst seenSizeFile
KNX Switch actuator 8ch 1.0 latest$02081AAC2026-11-25126 KBDownload

About this file

This is the official ETS product database for the Arlight KNX-708-SW10-DIN (025665), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.