KNX-704-SW16-DIN/KNX-704-SW20-DIN 025661
Arlight · Order number 025661 · Actuator › Switch
KNX-704-SW16-DIN/KNX-704-SW20-DIN
Download .knxprod KNX Switch actuator 4ch 1.0 · 98 KB
Product
| Manufacturer | Arlight |
|---|---|
| Product name | KNX-704-SW16-DIN/KNX-704-SW20-DIN |
| Order number | 025661 |
| Hardware | KNX-704-SW16-DIN/KNX-704-SW20-DIN |
| Medium | Twisted Pair |
| Bus current (mA) | 12 |
| Rail mounted | Yes |
| Registration | Certified |
| Languages | en-US |
| Catalog entry | M-01C4_H-0SXXXX-16-O0085_HP-0206-10-B315-O0085_CI-025661-16 |
| Fingerprint | B315 |
| SHA-256 | 374fddd829b558a86cb31743f8c730a521054bdd4705ec75b3fc13082804e337 |
| First seen | 2026-11-25 |
| Markets | Belarus, Kazakhstan, Russia |
Application program: KNX Switch actuator 4ch 1.0
| Application number | $0206 |
|---|---|
| Version | 1.0 |
| Mask version | MV-0705 (7.5) |
| KNX Data Secure | No |
| Parameters | 457 |
| Group objects | 103 |
Group objects (103)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | General | In operation | 1 Bit | 1.2 boolean | CRT |
| 1 | General | safety priority 1 | 1 Bit | CWU | |
| 2 | General | safety priority 2 | 1 Bit | CWU | |
| 3 | Output A | reply the switch status, A | 1 Bit | 1.1 switch | CRT |
| 3 | Output A | send the switch status, A | 1 Bit | 1.1 switch | CRT |
| 3 | Output A | Reply status of contact , A | 1 Bit | 1.1 switch | CRT |
| 4 | Output A | Switch, A | 1 Bit | 1.1 switch | CW |
| 4 | Output A | on-off of regulating , A | 1 Bit | 1.1 switch | CW |
| 5 | Output A | Switch out with delay, A | 1 Bit | 1.1 switch | CW |
| 5 | Output A | Switch out with flashing, A | 1 Bit | 1.10 start/stop | CW |
| 5 | Output A | Output of staircase lighting,A | 1 Bit | 1.10 start/stop | CW |
| 5 | Output A | Status (continuous),1 bit , A | 1 Bit | 1.1 switch | CRT |
| 6 | Output A | Switch time function, A | 1 Bit | 1.3 enable | CW |
| 7 | Output A | Warning of staircase , A | 1 Bit | CRT | |
| 7 | Output A | report fault, regulating , A | 1 Bit | CRT | |
| 8 | Output A | Duration of staircase , A | 2 Bytes | 7.1 pulses | CRW |
| 9 | Output A | Call preset 1/2 , A | 1 Bit | CW | |
| 10 | Output A | Store preset 1/2, A | 1 Bit | CW | |
| 10 | Output A | Trigger switch regularly , A | 1 Bit | CW | |
| 11 | Output A | Input 1 of logic , A | 1 Bit | 1.1 switch | CW |
| 12 | Output A | Input 2 of logic , A | 1 Bit | 1.1 switch | CW |
| 13 | Output A | Scene handle, A | 1 Byte | CW | |
| 13 | Output A | Status (continuous),1 byte, A | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 14 | Output A | Change threshold 1, A | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 14 | Output A | continuous of regulating , A | 1 Byte | 5.1 percentage (0..100%) | CW |
| 15 | Output A | Threshold input , A | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 16 | Output A | Forced output , A | 1 Bit | CW | |
| 16 | Output A | forced operation,regulating, A | 1 Bit | CW | |
| 17 | Output B | reply the switch status, B | 1 Bit | 1.1 switch | CRT |
| 17 | Output B | send the switch status, B | 1 Bit | 1.1 switch | CRT |
| 17 | Output B | Reply status of contact , B | 1 Bit | 1.1 switch | CRT |
| 18 | Output B | Switch, B | 1 Bit | 1.1 switch | CW |
| 18 | Output B | on-off of regulating , B | 1 Bit | 1.1 switch | CW |
| 19 | Output B | Switch out with delay, B | 1 Bit | 1.1 switch | CW |
| 19 | Output B | Output of staircase lighting,B | 1 Bit | 1.10 start/stop | CW |
| 19 | Output B | Switch out with flashing, B | 1 Bit | 1.10 start/stop | CW |
| 19 | Output B | Status (continuous),1 bit, B | 1 Bit | 1.1 switch | CRT |
| 20 | Output B | Switch time function, B | 1 Bit | 1.3 enable | CW |
| 21 | Output B | Warning of staircase , B | 1 Bit | CRT | |
| 21 | Output B | report fault, regulating , B | 1 Bit | CRT | |
| 22 | Output B | Duration of staircase , B | 2 Bytes | 7.1 pulses | CRW |
| 23 | Output B | Call preset 1/2 , B | 1 Bit | CW | |
| 24 | Output B | Store preset 1/2, B | 1 Bit | CW | |
| 24 | Output B | Trigger switch regularly , B | 1 Bit | CW | |
| 25 | Output B | Input 1 of logic , B | 1 Bit | 1.1 switch | CW |
| 26 | Output B | Input 2 of logic , B | 1 Bit | 1.1 switch | CW |
| 27 | Output B | Scene handle, B | 1 Byte | CW | |
| 27 | Output B | Status (continuous),1 byte, B | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 28 | Output B | Change threshold 1, B | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 28 | Output B | continuous of regulating , B | 1 Byte | 5.1 percentage (0..100%) | CW |
| 29 | Output B | Threshold input , B | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 30 | Output B | Forced output , B | 1 Bit | CW | |
| 30 | Output B | forced operation,regulating, B | 1 Bit | CW | |
| 31 | Output C | reply the switch status, C | 1 Bit | 1.1 switch | CRT |
| 31 | Output C | send the switch status, C | 1 Bit | 1.1 switch | CRT |
| 31 | Output C | Reply status of contact , C | 1 Bit | 1.1 switch | CRT |
| 32 | Output C | Switch, C | 1 Bit | 1.1 switch | CW |
| 32 | Output C | on-off of regulating , C | 1 Bit | 1.1 switch | CW |
| 33 | Output C | Switch out with delay, C | 1 Bit | 1.1 switch | CW |
| 33 | Output C | Output of staircase lighting,C | 1 Bit | 1.10 start/stop | CW |
| 33 | Output C | Switch out with flashing, C | 1 Bit | 1.10 start/stop | CW |
| 33 | Output C | Status (continuous),1 bit , C | 1 Bit | 1.1 switch | CRT |
| 34 | Output C | Switch time function, C | 1 Bit | 1.3 enable | CW |
| 35 | Output C | Warning of staircase , C | 1 Bit | CRT | |
| 35 | Output C | report fault, regulating , C | 1 Bit | CRT | |
| 36 | Output C | Duration of staircase , C | 2 Bytes | 7.1 pulses | CRW |
| 37 | Output C | Call preset 1/2 , C | 1 Bit | CW | |
| 38 | Output C | Store preset 1/2, C | 1 Bit | CW | |
| 38 | Output C | Trigger switch regularly , C | 1 Bit | CW | |
| 39 | Output C | Input 1 of logic , C | 1 Bit | 1.1 switch | CW |
| 40 | Output C | Input 2 of logic , C | 1 Bit | 1.1 switch | CW |
| 41 | Output C | Scene handle, C | 1 Byte | CW | |
| 41 | Output C | Status (continuous),1 byte, C | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 42 | Output C | Change threshold 1, C | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 42 | Output C | continuous of regulating , C | 1 Byte | 5.1 percentage (0..100%) | CW |
| 43 | Output C | Threshold input , C | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 44 | Output C | Forced output , C | 1 Bit | CW | |
| 44 | Output C | forced operation,regulating, C | 1 Bit | CW | |
| 45 | Output D | reply the switch status, D | 1 Bit | 1.1 switch | CRT |
| 45 | Output D | send the switch status, D | 1 Bit | 1.1 switch | CRT |
| 45 | Output D | Reply status of contact , D | 1 Bit | 1.1 switch | CRT |
| 46 | Output D | Switch, D | 1 Bit | 1.1 switch | CW |
| 46 | Output D | on-off of regulating , D | 1 Bit | 1.1 switch | CW |
| 47 | Output D | Switch out with delay, D | 1 Bit | 1.1 switch | CW |
| 47 | Output D | Output of staircase lighting,D | 1 Bit | 1.10 start/stop | CW |
| 47 | Output D | Switch out with flashing, D | 1 Bit | 1.10 start/stop | CW |
| 47 | Output D | Status (continuous),1 bit , D | 1 Bit | 1.1 switch | CRT |
| 48 | Output D | Switch time function, D | 1 Bit | 1.3 enable | CW |
| 49 | Output D | Warning of staircase , D | 1 Bit | CRT | |
| 49 | Output D | report fault, regulating , D | 1 Bit | CRT | |
| 50 | Output D | Duration of staircase , D | 2 Bytes | 7.1 pulses | CRW |
| 51 | Output D | Call preset 1/2 , D | 1 Bit | CW | |
| 52 | Output D | Store preset 1/2, D | 1 Bit | CW | |
| 52 | Output D | Trigger switch regularly , D | 1 Bit | CW | |
| 53 | Output D | Input 1 of logic , D | 1 Bit | 1.1 switch | CW |
| 54 | Output D | Input 2 of logic , D | 1 Bit | 1.1 switch | CW |
| 55 | Output D | Scene handle, D | 1 Byte | CW | |
| 55 | Output D | Status (continuous),1 byte, D | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 56 | Output D | Change threshold 1, D | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 56 | Output D | continuous of regulating , D | 1 Byte | 5.1 percentage (0..100%) | CW |
| 57 | Output D | Threshold input , D | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 58 | Output D | Forced output , D | 1 Bit | CW | |
| 58 | Output D | forced operation,regulating, D | 1 Bit | CW |
Parameters (86)
| Parameter | Type | Default |
|---|---|---|
| Operation delay after recovery of bus voltage(1...250s) | unsignedInt 1…250 | 1 |
| Sending cycle of In operation telegram (1......240s , 0=inactive) | unsignedInt 0…240 | 0 |
| Enable safety priority function | list | disable |
| ---set safety priority 1: | list | inactive |
| Control period of safety priority 1 (1......240 s, 0=inactive) | unsignedInt 0…240 | 0 |
| ---set safety priority 2: | list | inactive |
| Control period of safety priority 2 (1......240 s, 0=inactive) | unsignedInt 0…240 | 0 |
| =====N o t e===== Normal, object value map switch on/off | list | 1=switch on; 0=switch off |
| Work mode of the channel | list | Switch actuator |
| If bus voltage recovery,contact is | list | unchange |
| If bus voltage fail,contact is | list | unchange |
| Object value of telegram switch after bus voltage recovery | list | not write |
| Set the reply mode of switch status | list | no reply |
| Object value of switch status : | list | 0=contact open ; 1=contact close |
| Contact position if tele. value is 1 (0 is opposite of 1 if changed) | list | close |
| Special functions of switch actuator mode | list | inactive |
| Function of time for switch is | list | disable |
| Function of preset for switch is | list | disable |
| Function of logic for switch is | list | disable |
| Function of scene for switch is | list | disable |
| Function of threshold for switch is | list | disable |
| Function of safety for switch is | list | disable |
| Function of forced for switch is | list | disable |
| The mode of time function | list | delay switch |
| Delay for switch on : --(0...240 minutes) | unsignedInt 0…240 | 0 |
| --(0...59 seconds) | unsignedInt 0…59 | 0 |
| Delay for switch off : --(0...240 minutes) | unsignedInt 0…240 | 0 |
| Number of ON-impulses (1...255 , 0=no limited) | unsignedInt 0…255 | 0 |
| Contact position after flashing | list | unchange |
| The mode of control for flashing | list | Start with 1 , Stop with 0" |
| Duration of staircase lighting --(0...1000 minutes) | unsignedInt 0…1000 | 2 |
| The mode of control for staircase lighting is | list | Start with 0/1 , can not be stop |
| During the lighting time, if receive the Start telegram, | list | restart duration of staircase lighting |
| Warning mode for ending of staircase lighting | list | nothing |
| --The warning time for end of staircase lighting(0...59 s) | unsignedInt 0…59 | 0 |
| Modify the duration via object (0...60059 seconds) | list | disable |
| Action for preset 1(object value=0) | list | None |
| Action for preset 2(object value=1) | list | OFF |
| Setting for preset via telegram is | list | disable |
| The input 0 (switch object) for logic is | list | disable |
| The input 1 of logic is | list | disable |
| Function type between input0 and input1 | list | AND |
| Result is inverted | list | NO |
| Value of input 1 after bus voltage recovery : | list | 0" |
| The input 2 of logic is | list | disable |
| Function type between input2 and input0/1 | list | AND |
| Value of input 2 after bus voltage recovery : | list | 0" |
| 1> channel is assigned to (1...64 scene NO.,0= no allocation) | unsignedInt 0…64 | 0 |
| --Standard output value is | list | OFF |
| 2> channel is assigned to (1...64 scene NO.,0= no allocation) | unsignedInt 0…64 | 0 |
| 3> channel is assigned to (1...64 scene NO.,0= no allocation) | unsignedInt 0…64 | 0 |
| 4> channel is assigned to (1...64 scene NO.,0= no allocation) | unsignedInt 0…64 | 0 |
| 5> channel is assigned to (1...64 scene NO.,0= no allocation) | unsignedInt 0…64 | 0 |
| Threshold 1 value | unsignedInt 0…255 | 80 |
| Threshold 2 value | unsignedInt 0…255 | 200 |
| Change threshold 1via object : | list | disable |
| Threshold behaviour | list | without hysteresis |
| --If falling below lower threshold, contact position | list | unchange |
| --If exceeding upper threshold, contact position | list | unchange |
| --If lower < object value < upper contact position | list | unchange |
| Setting of safety | list | on parameter-window General" |
| Contact position if safety priority 1 | list | unchange |
| Contact position if safety priority 2 | list | unchange |
| Contact position if forced operation | list | unchange |
| If bus voltage fail ,contact is | list | unchange |
| If bus voltage recovery, the duty cycle of dynamic regulate | list | 0%(OFF) |
| PWM cycle time for continuous control (1...240 minutes) | unsignedInt 0…240 | 3 |
| PWM cycle time for continuous control (0...59 seconds | unsignedInt 0…59 | 0 |
| Control telegram is received as | list | 1 bit ( on-off control ) |
| Reply the status of channel for continuous control | list | nothing |
| Reply the status of contact state | list | nothing |
| Special functions of dynamic regulating actuator mode | list | inactive |
| Function for monitoring is | list | disable |
| Function of forced operation is | list | disable |
| Function of regular switch is | list | disable |
| Function of safety operation is | list | disable |
| Cyclic monitoring --in minutes (0...240 minutes) | unsignedInt 0…240 | 60 |
| --in seconds (0...59 seconds) | unsignedInt 0…59 | 0 |
| The duty cycle of dynamic regulating during fault | list | unchange |
| sending object report fault is | list | disable |
| The duty cycle of dynamic regulating during forced operation | list | unchange |
| Time of switch regular in minutes (0..255) | unsignedInt 0…255 | 10 |
| Automatic switch regularly | list | disable |
| The duty cycle of dynamic regulating during safety 1 operation | list | unchange |
| The duty cycle of dynamic regulating during safety 2 operation | list | unchange |
| Object value of switch status : | list | 0=contact close ; 1=contact open |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| KNX Switch actuator 4ch 1.0 latest | $0206 | B315 | 2026-11-25 | 98 KB | Download |
About this file
This is the official ETS product database for the Arlight KNX-704-SW16-DIN/KNX-704-SW20-DIN (025661), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from Arlight
- KNX-104-DIM-DIN 023041
- KNX-204-DIM-DIN 023042
- KNX-712-SW16-DIN 025662
- KNX-724-SW10-DIN 025664
- KNX-708-SW10-DIN 025665
- KNX-704-BLIND-DIN 025671
- KNX-710-0-10-DIN 025680
- KNX-4063-82-WTO-CL-DIN KNX-4063-82-WTO-CL-DIN
- KNX-7043-82-DRO-DIN KNX-7043-82-DRO-DIN
- KNX-7083-82-DRO-MF-DIN KNX-7083-82-DRO-MF-DIN
- KNX-7123-82-DRO-DIN KNX-7123-82-DRO-DIN
- KNX-7242-72-DRO-DIN KNX-7242-72-DRO-DIN