KNX-113-35-IN 025670
Arlight · Order number 025670 · KNX-113-35-IN › KNX-113-35-IN
KNX-113-35-IN
Download .knxprod KNX Temperature Control Panel 3.5" 1.0 · 133 KB
Product
| Manufacturer | Arlight |
|---|---|
| Product name | KNX-113-35-IN |
| Order number | 025670 |
| Hardware | KNX-113-35-IN |
| Medium | Twisted Pair |
| Rail mounted | No |
| Registration | Certified |
| Languages | en-US |
| Catalog entry | M-01C4_H-0UXXXX-16-O0085_HP-0502-10-02CB-O0085_CI-025670-16 |
| Fingerprint | 02CB |
| SHA-256 | 5cd2b3f484fb6abef617d8fab2e3b61a037880774012f71d3c657491c6bcc0bb |
| First seen | 2026-11-25 |
| Markets | Belarus, Kazakhstan, Russia |
Application program: KNX Temperature Control Panel 3.5" 1.0
| Application number | $0502 |
|---|---|
| Version | 1.0 |
| Mask version | MV-0705 (7.5) |
| KNX Data Secure | No |
| Parameters | 692 |
| Group objects | 240 |
Group objects (240)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | In operation | General | 1 Bit | 1.1 switch | CT |
| 1 | Day/night mode | Day/night switch | 1 Bit | 1.1 switch | CT |
| 1 | Day/night mode | Day/night switch | 1 Bit | 1.1 switch | CRW |
| 2 | Input external temperature | Temperature | 2 Bytes | 9.1 temperature (°C) | CRW |
| 3 | Actual temperature | Temperature | 2 Bytes | 9.1 temperature (°C) | CRT |
| 4 | rel.humidity | Humidity | 2 Bytes | CRT | |
| 5 | Operating mode forcing object | Setpoint temperature | 1 Byte | CRW | |
| 6 | Windows status | Setpoint temperature | 1 Bit | 1.1 switch | CRW |
| 7 | Presence object | Setpoint temperature | 1 Bit | 1.1 switch | CRW |
| 8 | Active comfort mode | Setpoint temperature | 1 Bit | 1.1 switch | CRW |
| 9 | Active standby mode | Setpoint temperature | 1 Bit | 1.1 switch | CRW |
| 10 | Active night mode | Setpoint temperature | 1 Bit | 1.1 switch | CRW |
| 11 | Active frost/heat protection mode | Setpoint temperature | 1 Bit | 1.1 switch | CRW |
| 12 | Temperature operating mode switchover | Setpoint temperature | 1 Byte | CRWT | |
| 13 | Heating/cooling switchover | Temperature control | 1 Bit | 1.1 switch | CRT |
| 14 | Basic comfort temperature | Setpoint temperature | 2 Bytes | 9.1 temperature (°C) | CRW |
| 14 | Basic comfort temperature (at heating) | Setpoint temperature | 2 Bytes | 9.1 temperature (°C) | CRW |
| 15 | Heating setpoint | Setpoint temperature | 2 Bytes | 9.1 temperature (°C) | CRWT |
| 16 | Cooling setpoint | Setpoint temperature | 2 Bytes | 9.1 temperature (°C) | CRWT |
| 17 | Output HVAC status | Temperature control | 1 Byte | CRT | |
| 18 | Output RHCC status | Temperature control | 2 Bytes | CRT | |
| 19 | Basic heating/cooling control value | Temperature control | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 19 | Basic heating/cooling control value | Temperature control | 1 Bit | 1.1 switch | CRT |
| 19 | Basic heating control value | Temperature control | 1 Bit | 1.1 switch | CRT |
| 19 | Basic heating control value | Temperature control | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 20 | Basic cooling control value | Temperature control | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 20 | Basic cooling control value | Temperature control | 1 Bit | 1.1 switch | CRT |
| 21 | Automatic fan ON/OFF | Temperature control | 1 Bit | 1.1 switch | CRT |
| 21 | Manual fan ON/OFF | Temperature control | 1 Bit | 1.1 switch | CRT |
| 22 | Fan manual stage | Temperature control | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 23 | Lock temperature control | Temperature control | 1 Bit | 1.1 switch | CRW |
| 24 | Additional heating/cooling control value | Temperature control | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 24 | Additional heating/cooling control value | Temperature control | 1 Bit | 1.1 switch | CRT |
| 24 | Additional heating control value | Temperature control | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 24 | Additional heating control value | Temperature control | 1 Bit | 1.1 switch | CRT |
| 25 | Additional cooling control value | Temperature control | 1 Bit | 1.1 switch | CRT |
| 25 | Additional cooling control value | Temperature control | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 26 | Lock additional stage | Temperature control | 1 Bit | 1.1 switch | CRW |
| 27 | Change temperature threshold value 1 | Temperature threshold value 1 | 2 Bytes | 9.1 temperature (°C) | CRW |
| 28 | 1 bit output, temperature | Temperature threshold value 1 | 1 Bit | 1.1 switch | CRT |
| 29 | 1 byte output, temperature | Temperature threshold value 1 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 30 | Temperature threshold value 1 block | Temperature threshold value 1 | 1 Bit | 1.1 switch | CRW |
| 31 | Change temperature threshold value 2 | Temperature threshold value 2 | 2 Bytes | 9.1 temperature (°C) | CRW |
| 32 | 1 bit output, temperature | Temperature threshold value 2 | 1 Bit | 1.1 switch | CRT |
| 33 | 1 byte output, temperature | Temperature threshold value 2 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 34 | Temperature threshold value 2 block | Temperature threshold value 2 | 1 Bit | 1.1 switch | CRW |
| 35 | Change humidity threshold value 1 | Humidity threshold value 1 | 2 Bytes | CRW | |
| 36 | 1 bit output, humidity | Humidity threshold value 1 | 1 Bit | 1.1 switch | CRT |
| 37 | 1 byte output, humidity | Humidity threshold value 1 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 38 | Humidity threshold value 1 block | Humidity threshold value 1 | 1 Bit | 1.1 switch | CRW |
| 39 | Change humidity threshold value 2 | Humidity threshold value 2 | 2 Bytes | CRW | |
| 40 | 1 bit output, humidity | Humidity threshold value 2 | 1 Bit | 1.1 switch | CRT |
| 41 | 1 byte output, humidity | Humidity threshold value 2 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 42 | Humidity threshold value 2 block | Humidity threshold value 2 | 1 Bit | 1.1 switch | CRW |
| 43 | Logic input A | Logic input | 1 Bit | 1.1 switch | CRW |
| 44 | Logic input B | Logic input | 1 Bit | 1.1 switch | CRW |
| 45 | Logic 1,1 bit output | Logic 1 | 1 Bit | 1.1 switch | CRT |
| 46 | Logic 1,1 byte output | Logic 1 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 47 | Logic 1 block | Logic 1 | 1 Bit | 1.1 switch | CRW |
| 48 | Logic 2,1 bit output | Logic 2 | 1 Bit | 1.1 switch | CRT |
| 49 | Logic 2,1 byte output | Logic 2 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 50 | Logic 2 block | Logic 2 | 1 Bit | 1.1 switch | CRW |
| 51 | Time | Time | 3 Bytes | 10.1 time of day | CRWT |
| 52 | Disable room temperature timer | Time | 1 Bit | 1.1 switch | CW |
| 53 | Output shutter UP/DOWN | CH A Blind | 1 Bit | 1.8 up/down | CT |
| 53 | Output shutter UP/DOWN | CH A Blind | 1 Byte | 5.1 percentage (0..100%) | CT |
| 53 | Switch 1, input 1 | CH A Switch | 1 Bit | 1.1 switch | CWT |
| 53 | Switch | CH A Switch | 1 Bit | 1.1 switch | CWT |
| 53 | Input 1, Scene | Scene number | 1 Byte | CT | |
| 54 | Output Stop/lamella adj | CH A Blind | 1 Bit | CT | |
| 54 | Output Stop/lamella adj | CH A Blind | 1 Byte | 5.1 percentage (0..100%) | CT |
| 54 | Switch 2, input 1 | CH A switch | 1 Bit | 1.1 switch | CT |
| 54 | Dimming | CH A Dimming | 4 Bit | 3.7 dimming control | CT |
| 55 | Disable input 1 | CH A Disable | 1 Bit | 1.1 switch | CW |
| 56 | Output shutter UP/DOWN | CH B Blind | 1 Bit | 1.8 up/down | CT |
| 56 | Output shutter UP/DOWN | CH B Blind | 1 Byte | 5.1 percentage (0..100%) | CT |
| 56 | Switch 1, input 2 | CH B Switch | 1 Bit | 1.1 switch | CWT |
| 56 | Switch | CH B Switch | 1 Bit | 1.1 switch | CWT |
| 56 | Input 2 , Scene | Scene number | 1 Byte | CT | |
| 57 | Output Stop/lamella adj | CH B Blind | 1 Bit | CT | |
| 57 | Output Stop/lamella adj | CH B Blind | 1 Byte | 5.1 percentage (0..100%) | CT |
| 57 | Switch 2, input 2 | CH B switch | 1 Bit | 1.1 switch | CT |
| 57 | Dimming | CH B Dimming | 4 Bit | 3.7 dimming control | CT |
| 58 | Disable input 2 | CH B Disable | 1 Bit | 1.1 switch | CW |
| 59 | Output shutter UP/DOWN | CH C Blind | 1 Bit | 1.8 up/down | CT |
| 59 | Output shutter UP/DOWN | CH C Blind | 1 Byte | 5.1 percentage (0..100%) | CT |
| 59 | Switch 1, input 3 | CH C Switch | 1 Bit | 1.1 switch | CWT |
| 59 | Switch | CH C Switch | 1 Bit | 1.1 switch | CWT |
| 59 | Input 3, Scene | Scene number | 1 Byte | CT | |
| 60 | Output Stop/lamella adj | CH C Blind | 1 Bit | CT | |
| 60 | Output Stop/lamella adj | CH C Blind | 1 Byte | 5.1 percentage (0..100%) | CT |
| 60 | Switch 2, input 3 | CH C switch | 1 Bit | 1.1 switch | CT |
| 60 | Dimming | CH C Dimming | 4 Bit | 3.7 dimming control | CT |
| 61 | Disable input 3 | CH C Disable | 1 Bit | 1.1 switch | CW |
| 62 | Floor temperature | CH D Temperature | 2 Bytes | 9.1 temperature (°C) | CRT |
| 63 | IR command number | Temperature control | 1 Byte | CT | |
| 64 | Air condition on/off | Temperature control | 1 Bit | 1.1 switch | CT |
| 65 | Mode heating/cooling | Temperature control | 1 Bit | 1.1 switch | CT |
| 66 | Switch to high/medium speed | Temperature control | 1 Bit | 1.1 switch | CT |
| 67 | Switch to low/auto speed | Temperature control | 1 Bit | 1.1 switch | CT |
| 68 | setpoint for heating 16/17 | Setpoint temperature | 1 Bit | 1.1 switch | CT |
| 69 | setpoint for heating 18/19 | Setpoint temperature | 1 Bit | 1.1 switch | CT |
| 70 | setpoint for heating 20/21 | Setpoint temperature | 1 Bit | 1.1 switch | CT |
| 71 | setpoint for heating 22/23 | Setpoint temperature | 1 Bit | 1.1 switch | CT |
| 72 | setpoint for heating 24/25 | Setpoint temperature | 1 Bit | 1.1 switch | CT |
| 73 | setpoint for heating 26/27 | Setpoint temperature | 1 Bit | 1.1 switch | CT |
| 74 | setpoint for heating 28/29 | Setpoint temperature | 1 Bit | 1.1 switch | CT |
| 75 | setpoint for heating 30/31 | Setpoint temperature | 1 Bit | 1.1 switch | CT |
| 76 | setpoint for cooling 16/17 | Setpoint temperature | 1 Bit | 1.1 switch | CT |
| 77 | setpoint for cooling 18/19 | Setpoint temperature | 1 Bit | 1.1 switch | CT |
| 78 | setpoint for cooling 20/21 | Setpoint temperature | 1 Bit | 1.1 switch | CT |
| 79 | setpoint for cooling 22/23 | Setpoint temperature | 1 Bit | 1.1 switch | CT |
| 80 | setpoint for cooling 24/25 | Setpoint temperature | 1 Bit | 1.1 switch | CT |
| 81 | setpoint for cooling 26/27 | Setpoint temperature | 1 Bit | 1.1 switch | CT |
| 82 | setpoint for cooling 28/29 | Setpoint temperature | 1 Bit | 1.1 switch | CT |
| 83 | setpoint for cooling 30/31 | Setpoint temperature | 1 Bit | 1.1 switch | CT |
| 84 | outdoor temperature | Temperature | 2 Bytes | 9.1 temperature (°C) | CRW |
| 85 | Heating standby setpoint | Setpoint temperature | 2 Bytes | 9.1 temperature (°C) | CRW |
| 86 | Heating night setpoint | Setpoint temperature | 2 Bytes | 9.1 temperature (°C) | CRW |
| 87 | Setpoint heat protection | Setpoint temperature | 2 Bytes | 9.1 temperature (°C) | CRW |
| 87 | Setpoint frost protection | Setpoint temperature | 2 Bytes | 9.1 temperature (°C) | CRW |
| 88 | Cooling comfort setpoint | Setpoint temperature | 2 Bytes | 9.1 temperature (°C) | CRW |
| 88 | Basic comfort temperature | Setpoint temperature | 2 Bytes | 9.1 temperature (°C) | CRW |
| 89 | Cooling standby setpoint | Setpoint temperature | 2 Bytes | 9.1 temperature (°C) | CRW |
| 90 | Cooling night setpoint | Setpoint temperature | 2 Bytes | 9.1 temperature (°C) | CRW |
| 91 | Setpoint frost protection | Setpoint temperature | 2 Bytes | 9.1 temperature (°C) | CRW |
| 91 | Setpoint heat protection | Setpoint temperature | 2 Bytes | 9.1 temperature (°C) | CRW |
| 92 | 4 byte value[0..4294967295] | Time 1 value | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 92 | 4 bit value[0..15] | Time 1 value | 4 Bit | 3.7 dimming control | CT |
| 92 | 2 bit value[0..3] | Time 1 value | 2 Bit | 2.2 boolean control | CT |
| 92 | 1 bit value[0..1] | Time 1 value | 1 Bit | 1.1 switch | CT |
| 92 | 2 byte value[0..65535] | Time 1 value | 2 Bytes | 7.1 pulses | CT |
| 92 | 2 byte value[-32768..32767] | Time 1 value | 2 Bytes | 8.1 pulses difference | CT |
| 92 | 1 byte value[0..255] | Time 1 value | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 93 | 4 bit value[0..15] | Time 2 value | 4 Bit | 3.7 dimming control | CT |
| 93 | 1 bit value[0..1] | Time 2 value | 1 Bit | 1.1 switch | CT |
| 93 | 1 byte value[0..255] | Time 2 value | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 93 | 4 byte value[0..4294967295] | Time 2 value | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 93 | 2 byte value[0..65535] | Time 2 value | 2 Bytes | 7.1 pulses | CT |
| 93 | 2 bit value[0..3] | Time 2 value | 2 Bit | 2.2 boolean control | CT |
| 93 | 2 byte value[-32768..32767] | Time 2 value | 2 Bytes | 8.1 pulses difference | CT |
| 94 | 2 bit value[0..3] | Time 3 value | 2 Bit | 2.2 boolean control | CT |
| 94 | 2 byte value[0..65535] | Time 3 value | 2 Bytes | 7.1 pulses | CT |
| 94 | 4 byte value[0..4294967295] | Time 3 value | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 94 | 2 byte value[-32768..32767] | Time 3 value | 2 Bytes | 8.1 pulses difference | CT |
| 94 | 1 bit value[0..1] | Time 3 value | 1 Bit | 1.1 switch | CT |
| 94 | 4 bit value[0..15] | Time 3 value | 4 Bit | 3.7 dimming control | CT |
| 94 | 1 byte value[0..255] | Time 3 value | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 95 | 4 byte value[0..4294967295] | Time 4 value | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 95 | 2 byte value[0..65535] | Time 4 value | 2 Bytes | 7.1 pulses | CT |
| 95 | 2 byte value[-32768..32767] | Time 4 value | 2 Bytes | 8.1 pulses difference | CT |
| 95 | 2 bit value[0..3] | Time 4 value | 2 Bit | 2.2 boolean control | CT |
| 95 | 1 bit value[0..1] | Time 4 value | 1 Bit | 1.1 switch | CT |
| 95 | 4 bit value[0..15] | Time 4 value | 4 Bit | 3.7 dimming control | CT |
| 95 | 1 byte value[0..255] | Time 4 value | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 96 | 4 bit value[0..15] | Time 5 value | 4 Bit | 3.7 dimming control | CT |
| 96 | 2 byte value[-32768..32767] | Time 5 value | 2 Bytes | 8.1 pulses difference | CT |
| 96 | 2 bit value[0..3] | Time 5 value | 2 Bit | 2.2 boolean control | CT |
| 96 | 1 bit value[0..1] | Time 5 value | 1 Bit | 1.1 switch | CT |
| 96 | 2 byte value[0..65535] | Time 5 value | 2 Bytes | 7.1 pulses | CT |
| 96 | 1 byte value[0..255] | Time 5 value | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 96 | 4 byte value[0..4294967295] | Time 5 value | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 97 | 4 byte value[0..4294967295] | Time 6 value | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 97 | 1 bit value[0..1] | Time 6 value | 1 Bit | 1.1 switch | CT |
| 97 | 2 byte value[0..65535] | Time 6 value | 2 Bytes | 7.1 pulses | CT |
| 97 | 2 bit value[0..3] | Time 6 value | 2 Bit | 2.2 boolean control | CT |
| 97 | 2 byte value[-32768..32767] | Time 6 value | 2 Bytes | 8.1 pulses difference | CT |
| 97 | 4 bit value[0..15] | Time 6 value | 4 Bit | 3.7 dimming control | CT |
| 97 | 1 byte value[0..255] | Time 6 value | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 98 | 4 byte value[0..4294967295] | Time 7 value | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 98 | 1 byte value[0..255] | Time 7 value | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 98 | 2 byte value[-32768..32767] | Time 7 value | 2 Bytes | 8.1 pulses difference | CT |
| 98 | 2 byte value[0..65535] | Time 7 value | 2 Bytes | 7.1 pulses | CT |
| 98 | 1 bit value[0..1] | Time 7 value | 1 Bit | 1.1 switch | CT |
| 98 | 2 bit value[0..3] | Time 7 value | 2 Bit | 2.2 boolean control | CT |
| 98 | 4 bit value[0..15] | Time 7 value | 4 Bit | 3.7 dimming control | CT |
| 99 | 1 bit value[0..1] | Time 8 value | 1 Bit | 1.1 switch | CT |
| 99 | 2 byte value[0..65535] | Time 8 value | 2 Bytes | 7.1 pulses | CT |
| 99 | 2 byte value[-32768..32767] | Time 8 value | 2 Bytes | 8.1 pulses difference | CT |
| 99 | 1 byte value[0..255] | Time 8 value | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 99 | 4 byte value[0..4294967295] | Time 8 value | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 99 | 2 bit value[0..3] | Time 8 value | 2 Bit | 2.2 boolean control | CT |
| 99 | 4 bit value[0..15] | Time 8 value | 4 Bit | 3.7 dimming control | CT |
| 100 | 4 byte value[0..4294967295] | Time 9 value | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 100 | 4 bit value[0..15] | Time 9 value | 4 Bit | 3.7 dimming control | CT |
| 100 | 1 byte value[0..255] | Time 9 value | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 100 | 2 byte value[-32768..32767] | Time 9 value | 2 Bytes | 8.1 pulses difference | CT |
| 100 | 2 byte value[0..65535] | Time 9 value | 2 Bytes | 7.1 pulses | CT |
| 100 | 1 bit value[0..1] | Time 9 value | 1 Bit | 1.1 switch | CT |
| 100 | 2 bit value[0..3] | Time 9 value | 2 Bit | 2.2 boolean control | CT |
| 101 | 4 byte value[0..4294967295] | Time 10 value | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 101 | 4 bit value[0..15] | Time 10 value | 4 Bit | 3.7 dimming control | CT |
| 101 | 2 bit value[0..3] | Time 10 value | 2 Bit | 2.2 boolean control | CT |
| 101 | 1 bit value[0..1] | Time 10 value | 1 Bit | 1.1 switch | CT |
| 101 | 2 byte value[0..65535] | Time 10 value | 2 Bytes | 7.1 pulses | CT |
| 101 | 2 byte value[-32768..32767] | Time 10 value | 2 Bytes | 8.1 pulses difference | CT |
| 101 | 1 byte value[0..255] | Time 10 value | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 102 | 4 byte value[0..4294967295] | Time 11 value | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 102 | 1 bit value[0..1] | Time 11 value | 1 Bit | 1.1 switch | CT |
| 102 | 4 bit value[0..15] | Time 11 value | 4 Bit | 3.7 dimming control | CT |
| 102 | 2 byte value[0..65535] | Time 11 value | 2 Bytes | 7.1 pulses | CT |
| 102 | 2 byte value[-32768..32767] | Time 11 value | 2 Bytes | 8.1 pulses difference | CT |
| 102 | 1 byte value[0..255] | Time 11 value | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 102 | 2 bit value[0..3] | Time 11 value | 2 Bit | 2.2 boolean control | CT |
| 103 | 1 byte value[0..255] | Time 12 value | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 103 | 2 bit value[0..3] | Time 12 value | 2 Bit | 2.2 boolean control | CT |
| 103 | 1 bit value[0..1] | Time 12 value | 1 Bit | 1.1 switch | CT |
| 103 | 4 bit value[0..15] | Time 12 value | 4 Bit | 3.7 dimming control | CT |
| 103 | 2 byte value[0..65535] | Time 12 value | 2 Bytes | 7.1 pulses | CT |
| 103 | 2 byte value[-32768..32767] | Time 12 value | 2 Bytes | 8.1 pulses difference | CT |
| 103 | 4 byte value[0..4294967295] | Time 12 value | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 104 | 2 byte value[0..65535] | Time 13 value | 2 Bytes | 7.1 pulses | CT |
| 104 | 4 byte value[0..4294967295] | Time 13 value | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 104 | 1 bit value[0..1] | Time 13 value | 1 Bit | 1.1 switch | CT |
| 104 | 1 byte value[0..255] | Time 13 value | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 104 | 4 bit value[0..15] | Time 13 value | 4 Bit | 3.7 dimming control | CT |
| 104 | 2 bit value[0..3] | Time 13 value | 2 Bit | 2.2 boolean control | CT |
| 104 | 2 byte value[-32768..32767] | Time 13 value | 2 Bytes | 8.1 pulses difference | CT |
| 105 | 2 byte value[0..65535] | Time 14 value | 2 Bytes | 7.1 pulses | CT |
| 105 | 4 byte value[0..4294967295] | Time 14 value | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 105 | 2 byte value[-32768..32767] | Time 14 value | 2 Bytes | 8.1 pulses difference | CT |
| 105 | 1 bit value[0..1] | Time 14 value | 1 Bit | 1.1 switch | CT |
| 105 | 2 bit value[0..3] | Time 14 value | 2 Bit | 2.2 boolean control | CT |
| 105 | 1 byte value[0..255] | Time 14 value | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 105 | 4 bit value[0..15] | Time 14 value | 4 Bit | 3.7 dimming control | CT |
| 106 | 2 byte value[-32768..32767] | Time 15 value | 2 Bytes | 8.1 pulses difference | CT |
| 106 | 2 byte value[0..65535] | Time 15 value | 2 Bytes | 7.1 pulses | CT |
| 106 | 4 byte value[0..4294967295] | Time 15 value | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 106 | 2 bit value[0..3] | Time 15 value | 2 Bit | 2.2 boolean control | CT |
| 106 | 1 bit value[0..1] | Time 15 value | 1 Bit | 1.1 switch | CT |
| 106 | 4 bit value[0..15] | Time 15 value | 4 Bit | 3.7 dimming control | CT |
| 106 | 1 byte value[0..255] | Time 15 value | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 107 | 2 byte value[-32768..32767] | Time 16 value | 2 Bytes | 8.1 pulses difference | CT |
| 107 | 2 byte value[0..65535] | Time 16 value | 2 Bytes | 7.1 pulses | CT |
| 107 | 4 byte value[0..4294967295] | Time 16 value | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 107 | 1 byte value[0..255] | Time 16 value | 1 Byte | 5.1 percentage (0..100%) | CT |
| 107 | 1 bit value[0..1] | Time 16 value | 1 Bit | 1.1 switch | CT |
| 107 | 2 bit value[0..3] | Time 16 value | 2 Bit | 2.2 boolean control | CT |
| 107 | 4 bit value[0..15] | Time 16 value | 4 Bit | 3.7 dimming control | CT |
| 108 | Unit on/off | Unit on/off | 1 Bit | 1.1 switch | CRWT |
Parameters (265)
| Parameter | Type | Default |
|---|---|---|
| Send In operation object | list | no |
| Transmission period of In operation object | list | 5 min |
| Temperature display | list | Celsius(C) |
| Backlight in no operation in day (%) | unsignedInt 0…100 | 60 |
| Backlight in operation in day (%) | unsignedInt 0…100 | 100 |
| Backlight in no operation at night (%) | unsignedInt 0…100 | 50 |
| Backlight in operation at night (%) | unsignedInt 0…100 | 90 |
| Time of backlight delay(s) | unsignedInt 5…50 | 5 |
| Switch day/night mode automatically | list | no |
| Time of switching to day at:Hour | unsignedInt 0…23 | 6 |
| Time of switching to day at:Miniute | unsignedInt 0…59 | 0 |
| Time of switching to night at:Hour | unsignedInt 0…23 | 18 |
| Time of switching to night at:Minitue | unsignedInt 0…59 | 0 |
| Time mode | list | 24H |
| Send current time | list | Do not send |
| Warning tone | list | disable |
| Control device | list | HVAC |
| Controller action when display off | list | Protect mode |
| Temperature control system | list | cooling |
| Heating and cooling share object | list | no |
| Temperature sensor | list | internal sensor |
| Internal temperature correction in 0.1Celsius | signedInt -128…127 | 0 |
| External temperature correction in 0.1Celsius | signedInt -128…127 | 0 |
| Weighting interior/exterior | list | 50% / 50% |
| Monitoring time of external sensor in min (0 = inactive) | unsignedInt 0…255 | 10 |
| Send temperature at variation of (Celsius) | list | 0.3 |
| Period of sending temperature | list | 2 min |
| Enalbe display outdoor temprature | list | disable |
| Indoor and outdoor temperature switch time (second) | unsignedInt 0…255 | 10 |
| Humidity correction in % | signedInt -15…15 | 0 |
| Send rel. humidity at variation of (%) | list | 1 |
| Period of sending humidity | list | 2 min |
| Operating mode after reset | list | comfort mode |
| Object type for operating mode switchover | list | 1 byte |
| Send setpoint | list | on change |
| Period of sending setpoint | list | 10 min |
| Switchover between heating and cooling | list | automatic switchover by dead zone |
| Control option after reset | list | heating |
| Automatic transmission heating/cooling switchover | list | when control option changes |
| Cyclic transmission of heating/cooling switchover in min (0 = inactive) | unsignedInt 0…255 | 0 |
| automatic transmission heating/cooling switchover | list | when control option changes |
| Period of sending HVAC status | list | 5 min |
| Period of sending HVAC and RHCC status | list | 5 min |
| Setpoint adjustment | list | relative adjustment |
| Basic comfort setpoint at cooling in 0.1Celsius | unsignedInt 0…500 | 230 |
| Basic comfort setpoint at heating in 0.1Celsius | unsignedInt 0…500 | 210 |
| Setpoint decrease for standby mode at heating in 0.1Celsius | unsignedInt 0…100 | 20 |
| Setpoint decrease for night mode at heating in 0.1Celsius | unsignedInt 0…100 | 40 |
| Setpoint frost protection at heating in 0.1Celsius | unsignedInt 0…255 | 70 |
| Positive dead zone between heating and cooling in 0.1Celsius | unsignedInt 0…100 | 20 |
| Setpoint increase for standby mode at cooling in 0.1Celsius | unsignedInt 0…100 | 20 |
| Setpoint increase for night mode at cooling in 0.1Celsius | unsignedInt 0…100 | 40 |
| Setpoint heat protection at cooling in 0.1Celsius | unsignedInt 0…500 | 350 |
| Heating comfort setpoint in 0.1Celsius | unsignedInt 0…500 | 210 |
| Heating standby setpoint in 0.1 Celsius | unsignedInt 0…500 | 190 |
| Heating night setpoint in 0.1Celsius | unsignedInt 0…500 | 170 |
| Cooling comfort setpoint in 0.1Celsius | unsignedInt 0…500 | 230 |
| Cooling standby setpoint in 0.1Celsius | unsignedInt 0…500 | 250 |
| Cooling night setpoint in 0.1Celsius | unsignedInt 0…500 | 270 |
| Minimum distance between heating setpoint and cooling setpoint | unsignedInt 0…100 | 20 |
| Control type | list | fan coil control |
| Invert control value | list | no |
| Control parameter of heating system | list | hot water heating (5 K / 150 min) |
| Send control value at variation of (%) (0 = inactive) | unsignedInt 0…15 | 4 |
| Proportional range in 0.1 Celsius | unsignedInt 10…100 | 40 |
| Period of sending control value in min (0 = inactive) | unsignedInt 0…255 | 10 |
| Reset time in min | unsignedInt 0…255 | 150 |
| Minimum control value in % at heating | unsignedInt 0…30 | 0 |
| Minimum control value in % | unsignedInt 0…30 | 0 |
| Maximum control value in % at heating | unsignedInt 70…100 | 100 |
| Maximum control value in % | unsignedInt 70…100 | 100 |
| Maximum control value in % at heating | unsignedInt 70…100 | 100 |
| PWM cycle time in min | unsignedInt 1…255 | 10 |
| Proportional range in 0.1 Celsius | unsignedInt 10…100 | 40 |
| Symmetrical hysteresis temperature in 0.1 Celsius at heating | unsignedInt 5…50 | 20 |
| Symmetrical hysteresis temperature in 0.1 Celsius | unsignedInt 5…50 | 20 |
| Symmetrical hysteresis temperature in 0.1 Celsius at cooling | unsignedInt 5…50 | 20 |
| Symmetrical hysteresis temperature in 0.1 Celsius at cooling | unsignedInt 5…50 | 20 |
| Control value type | list | 1 bit (ON/OFF) |
| Control parameter of cooling system | list | cooling ceiling (5 K / 240 min) |
| Minimum control value in % at cooling | unsignedInt 0…30 | 0 |
| Maximum control value in % at cooling | unsignedInt 70…100 | 100 |
| Automatic return from manual adjustment (0 =inactive, min) | unsignedInt 0…255 | 0 |
| Threshold value in % for fan speed 1 at heating | unsignedInt 0…100 | 20 |
| Threshold value in % for fan speed 2 at heating | unsignedInt 0…100 | 40 |
| Threshold value in % for fan speed 3 at heating | unsignedInt 0…100 | 80 |
| Fan speed for switching to comfort mode at heating | list | no change |
| Fan speed for switching to standby mode at heating | list | no change |
| Fan speed for switching to night mode at heating | list | no change |
| Fan speed for switching to frost/heat protection mode at heating | list | no change |
| Minimum control value in % at cooling | unsignedInt 0…30 | 0 |
| Threshold value in % for fan speed 1 at cooling | unsignedInt 0…100 | 20 |
| Threshold value in % for fan speed 2 at cooling | unsignedInt 0…100 | 40 |
| Threshold value in % for fan speed 3 at cooling | unsignedInt 0…100 | 80 |
| Fan speed for switching to comfort mode at cooling | list | no change |
| Fan speed for switching to standby mode at cooling | list | no change |
| Fan speed for switching to night mode at cooling | list | no change |
| Fan speed for switching to frost/heat protection mode at cooling | list | no change |
| Setpoint between basic and additional heating in 1C | unsignedInt 0…15 | 2 |
| Control type | list | continuous PI control |
| Symmetrical hysteresis temperature in 0.1 Celsius at heating | unsignedInt 5…50 | 20 |
| Symmetrical hysteresis temperature in 0.1 Celsius | unsignedInt 5…50 | 20 |
| Setpoint between basic and additional cooling in 1C | unsignedInt 0…15 | 2 |
| Number of fan levels | list | 3 levels |
| Switchover fan between auto and manual | list | object Automatic ON/OFF" |
| Temperature threshold value 1 | list | disable |
| Temperature threshold value 2 | list | disable |
| Humidity threshold value 1 | list | disable |
| Humidity threshold value 2 | list | disable |
| Temperature threshold value in 0.1 Celsius | unsignedInt 0…500 | 250 |
| Negative hysteresis temperature in 0.1 Celsius | unsignedInt 5…50 | 10 |
| If temperature is lower than threshold value | list | send following telegram once |
| Logic 1bit telegram value[0..1] | list | 0' |
| 1byte telegram value[0..255] | unsignedInt 0…255 | 0 |
| If temperature is upper than threshold value | list | send following telegram once |
| Logic 1bit telegram value[0..1] | list | 1' |
| 1byte telegram value[0..255] | unsignedInt 0…255 | 255 |
| Cycle time for temperature threshold value in min(if used) | unsignedInt 1…255 | 10 |
| Use block of the temperature threshold output | list | no |
| Behaviour when setting the lock | list | send the same telegram as upper threshold |
| Behaviour when releasing the lock | list | update |
| Negative hysteresis temperature in 0.1 Celsius | unsignedInt 5…50 | 20 |
| Behaviour when setting the lock | list | send the same telegram as lower threshold |
| humidity threshold value in % | unsignedInt 0…100 | 60 |
| Negative hysteresis humidity in % | unsignedInt 1…10 | 2 |
| If humidity is lower than threshold value | list | send following telegram once |
| If humidity is upper than threshold value | list | send following telegram once |
| Cycle time for humidity threshold value in min(if used) | unsignedInt 1…255 | 10 |
| Use block of the humidity threshold output | list | no |
| Active logic function | list | disable |
| Logic 1 | list | disable |
| Logic 2 | list | disable |
| The value of communication object input A after bus voltage recovery | list | 0' |
| The value of communication object input B after bus voltage recovery | list | 0' |
| input 1 | list | do not use |
| input 2 | list | do not use |
| input 3 | list | do not use |
| The logic function type between input 1 and input 2 | list | AND |
| The logic function type between input 3 and result of input 1/2 | list | AND |
| If logic result = '0' | list | send following telegram once |
| 1bit telegram value[0..1] | list | 0' |
| If logic result = '1' | list | send following telegram once |
| 1bit telegram value[0..1] | list | 1' |
| Cycle time for logic in min(if used) | unsignedInt 1…255 | 10 |
| Use block of the logic 1 output | list | no |
| Behaviour when setting the lock | list | the same as logic result = '0' |
| input 4 | list | do not use |
| input 5 | list | do not use |
| input 6 | list | do not use |
| The logic function type between input 4 and input 5 | list | AND |
| The logic function type between input 6 and result of input 4/5 | list | AND |
| Use block of the logic 2 output | list | no |
| Time 1 | list | disable |
| Week | list | Monday |
| Hour | unsignedInt 0…23 | 8 |
| Minute | unsignedInt 0…59 | 0 |
| Operating mode | list | unchange |
| Reaction at regular time | list | No reaction |
| Output value | unsignedInt 0…1 | 0 |
| Output value | unsignedInt 0…3 | 0 |
| Output value | unsignedInt 0…15 | 0 |
| Output value | unsignedInt 0…255 | 0 |
| Output value | signedInt -32768…32767 | 0 |
| Output value | unsignedInt 0…65535 | 0 |
| Output value | unsignedInt 0…4294967295 | 0 |
| Time 2 | list | disable |
| Time 3 | list | disable |
| Time 4 | list | disable |
| Time 5 | list | disable |
| Time 6 | list | disable |
| Time 7 | list | disable |
| Operating mode | list | frost/heat protection |
| Time 8 | list | disable |
| Time 9 | list | disable |
| Time 10 | list | disable |
| Time 11 | list | disable |
| Time 12 | list | disable |
| Time 13 | list | disable |
| Time 14 | list | disable |
| Time 15 | list | disable |
| Time 16 | list | disable |
| Pushbutton Interface Function | list | disable |
| Delay time after power on[1..255s] | unsignedInt 1…255 | 1 |
| Debounce time | list | 50ms |
| Limit number of Tele. | list | Yes |
| Telegrams per 17 senconds | list | 127 |
| Function of input 1 | list | No Function |
| Reaction on closing the contact (Rising edge) switch 1 | list | OFF |
| Reaction on opening the contact (Falling edge) switch 1 | list | no action |
| Reaction on closing the contact (Rising edge) switch 2 | list | OFF |
| Reaction on opening the contact (Falling edge) switch 2 | list | no action |
| Send object value after voltage recovery ( if YES not equal TOGGLE) | list | No |
| Cyclic send Tele.Tele.switch" | list | always |
| Interval of Tele.cyclic send: Base 1 | list | 20s |
| Interval of Tele.cyclic send: Base 2 | list | 20s |
| Factor[1..255] | unsignedInt 1…255 | 10 |
| Long operation after (Entry * 0.1s) | unsignedInt 3…250 | 10 |
| Reaction on short operation | list | No action |
| Reaction on long operation | list | brighter/darker |
| Step size for dimming | list | 1.56% |
| Transmission dimming stop telegram | list | yes |
| Cyclical transmission of dimming telegrams | list | disable |
| Time between two dimming telegrams | unsignedInt 3…250 | 10 |
| Long operation after | unsignedInt 3…250 | 10 |
| Function switchover blinds/roller shutte | list | Shutter |
| Objet type | list | 1 BIT |
| Cyclical transmission tele.repetition (Entry * 0.1s) | unsignedInt 3…250 | 30 |
| Value for position down(%) | unsignedInt 0…100 | 50 |
| Value for position up(%) | unsignedInt 0…100 | 0 |
| Value for slats position down(%) | unsignedInt 0…100 | 50 |
| Value for slats position up(%) | unsignedInt 0…100 | 0 |
| Number of scene | unsignedInt 1…64 | 1 |
| Storage function light scenes | list | disable |
| Long operation after | unsignedInt 3…250 | 30 |
| Function of input 2 | list | No Function |
| Function of input 3 | list | No Function |
| Function of input 4 | list | no function |
| Resistor of external temperature sensor | list | 33K |
| B value of external temperature sensor | list | 3950 |
| Limit temperature in 1Celsius | unsignedInt 1…50 | 35 |
| Negative hysteresis temperature (0.1 Celsius) | unsignedInt 5…50 | 5 |
| Acting on | list | basic heating |
| Setpoint | unsignedInt 16…32 | 25 |
| Object type for controlling air condition | list | 1 bit |
| Command for air condition on | unsignedInt 1…64 | 1 |
| Command for air condition off | unsignedInt 1…64 | 2 |
| Command for heating mode | unsignedInt 1…64 | 3 |
| Command for cooling mode | unsignedInt 1…64 | 4 |
| Command for fan speed high | unsignedInt 1…64 | 5 |
| Command for fan speed medium | unsignedInt 1…64 | 6 |
| Command for fan speed low | unsignedInt 1…64 | 7 |
| Command for fan speed auto/stop | unsignedInt 1…64 | 8 |
| Command for setpoint 16 Celsius for cooling | unsignedInt 1…64 | 9 |
| Command for setpoint 17 Celsius for cooling | unsignedInt 1…64 | 10 |
| Command for setpoint 18 Celsius for cooling | unsignedInt 1…64 | 11 |
| Command for setpoint 19 Celsius for cooling | unsignedInt 1…64 | 12 |
| Command for setpoint 20 Celsius for cooling | unsignedInt 1…64 | 13 |
| Command for setpoint 21 Celsius for cooling | unsignedInt 1…64 | 14 |
| Command for setpoint 22 Celsius for cooling | unsignedInt 1…64 | 15 |
| Command for setpoint 23 Celsius for cooling | unsignedInt 1…64 | 16 |
| Command for setpoint 24 Celsius for cooling | unsignedInt 1…64 | 17 |
| Command for setpoint 25 Celsius for cooling | unsignedInt 1…64 | 18 |
| Command for setpoint 26 Celsius for cooling | unsignedInt 1…64 | 19 |
| Command for setpoint 27 Celsius for cooling | unsignedInt 1…64 | 20 |
| Command for setpoint 28 Celsius for cooling | unsignedInt 1…64 | 21 |
| Command for setpoint 29 Celsius for cooling | unsignedInt 1…64 | 22 |
| Command for setpoint 30 Celsius for cooling | unsignedInt 1…64 | 23 |
| Command for setpoint 31 Celsius for cooling | unsignedInt 1…64 | 24 |
| Command for setpoint 16 Celsius for heating | unsignedInt 1…64 | 25 |
| Command for setpoint 17 Celsius for heating | unsignedInt 1…64 | 26 |
| Command for setpoint 18 Celsius for heating | unsignedInt 1…64 | 27 |
| Command for setpoint 19 Celsius for heating | unsignedInt 1…64 | 28 |
| Command for setpoint 20 Celsius for heating | unsignedInt 1…64 | 29 |
| Command for setpoint 21 Celsius for heating | unsignedInt 1…64 | 30 |
| Command for setpoint 22 Celsius for heating | unsignedInt 1…64 | 31 |
| Command for setpoint 23 Celsius for heating | unsignedInt 1…64 | 32 |
| Command for setpoint 24 Celsius for heating | unsignedInt 1…64 | 33 |
| Command for setpoint 25 Celsius for heating | unsignedInt 1…64 | 34 |
| Command for setpoint 26 Celsius for heating | unsignedInt 1…64 | 35 |
| Command for setpoint 27 Celsius for heating | unsignedInt 1…64 | 36 |
| Command for setpoint 28 Celsius for heating | unsignedInt 1…64 | 37 |
| Command for setpoint 29 Celsius for heating | unsignedInt 1…64 | 38 |
| Command for setpoint 30 Celsius for heating | unsignedInt 1…64 | 39 |
| Command for setpoint 31 Celsius for heating | unsignedInt 1…64 | 40 |
| Hour | unsignedInt 0…23 | 0 |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| KNX Temperature Control Panel 3.5" 1.0 latest | $0502 | 02CB | 2026-11-25 | 133 KB | Download |
About this file
This is the official ETS product database for the Arlight KNX-113-35-IN (025670), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from Arlight
- KNX-104-DIM-DIN 023041
- KNX-204-DIM-DIN 023042
- KNX-902-PS640-DIN 025542
- KNX-704-SW16-DIN/KNX-704-SW20-DIN 025661
- KNX-712-SW16-DIN 025662
- KNX-724-SW10-DIN 025664
- KNX-708-SW10-DIN 025665
- KNX-704-BLIND-DIN 025671
- KNX-305-IN 025672
- KNX-309-4DRY-DIN 025675
- KNX-304-ETH-DIN 025676
- KNX-309-4DRY-IN 025679