SA/S8.6.1.1 Switch Actuator,8-fold,6A,MDRC 6195/31
ABB AG - BUSCH-JAEGER · Order number 6195/31 · Output › Binary output, 8-fold
Schalten 8f 6A/3.2
Download .knxprod Switch 8f 6A/3.2 3.2 · 497 KB
Product
| Manufacturer | ABB AG - BUSCH-JAEGER |
|---|---|
| Product name | SA/S8.6.1.1 Switch Actuator,8-fold,6A,MDRC |
| Order number | 6195/31 |
| Product text | 6195/31 Binärausgang,8fach,6A,REG |
| Hardware | SA/S8.6.2.1 |
| Medium | Twisted Pair |
| Bus current (mA) | 12 |
| Rail mounted | Yes |
| Width (mm) | 144 |
| Registration | Registered |
| Languages | de-DE, en-US |
| Catalog entry | M-0007_H-2CDG.20110.20153.20R0011-1-O0002_HP-A089-32-B898-O0002_CI-6195.2F31-1 |
| Fingerprint | B898 |
| SHA-256 | f439fff88bf29a46c99de52c59b1675235d2e4ddac2f2346d1a03d4b1028ce23 |
| First seen | 2026-11-25 |
| Markets | Australia |
Application program: Schalten 8f 6A/3.2 3.2
| Application number | $A089 |
|---|---|
| Version | 3.2 |
| Mask version | MV-0701 (7.1) |
| KNX Data Secure | No |
| Parameters | 1051 |
| Group objects | 218 |
Group objects (218)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Allgemein | In Betrieb | 1 Bit | 1.2 boolean | CRT |
| 1 | Allgemein | Sicherheit Priorität 1 | 1 Bit | CWU | |
| 2 | Allgemein | Sicherheit Priorität 2 | 1 Bit | CWU | |
| 3 | Allgemein | Sicherheit Priorität 3 | 1 Bit | CWU | |
| 4 | Objekt 4 | Dummy | 1 Bit | 1.1 switch | |
| 5 | Objekt 5 | Dummy | 1 Bit | 1.1 switch | |
| 6 | Objekt 6 | Dummy | 1 Bit | 1.1 switch | |
| 7 | Objekt 7 | Dummy | 1 Bit | 1.1 switch | |
| 8 | Objekt 8 | Dummy | 1 Bit | 1.1 switch | |
| 9 | Objekt 9 | Dummy | 1 Bit | 1.1 switch | |
| 10 | Ausgang A | Stellwert (PWM) | 1 Byte | 5.1 percentage (0..100%) | CW |
| 10 | Ausgang A | Schalten | 1 Bit | 1.1 switch | CW |
| 11 | Ausgang A | Ventilspülung auslösen | 1 Bit | 1.1 switch | CW |
| 11 | Ausgang A | Dauer-EIN | 1 Bit | 1.1 switch | CW |
| 12 | Ausgang A | Status Ventilspülung | 1 Bit | 1.2 boolean | CT |
| 12 | Ausgang A | Zeitfunktion sperren | 1 Bit | 1.3 enable | CW |
| 13 | Ausgang A | Störung RTR | 1 Bit | CT | |
| 13 | Ausgang A | Treppenlicht Zeitdauer | 2 Bytes | 7.1 pulses | CRW |
| 14 | Ausgang A | Zwangsführung | 1 Bit | 1.3 enable | CW |
| 14 | Ausgang A | Treppenlicht vorwarnen | 1 Bit | CT | |
| 15 | Ausgang A | Status Heizen | 1 Byte | 5.1 percentage (0..100%) | CT |
| 15 | Ausgang A | Status Heizen | 1 Bit | 1.1 switch | CT |
| 15 | Ausgang A | Preset 1/2 aufrufen | 1 Bit | CW | |
| 16 | Ausgang A | Preset 1/2 setzen | 1 Bit | CW | |
| 17 | Ausgang A | 8-Bit-Szene | 1 Byte | CW | |
| 18 | Ausgang A | Log. Verknüpfung 1 | 1 Bit | 1.2 boolean | CW |
| 19 | Ausgang A | Log. Verknüpfung 2 | 1 Bit | 1.2 boolean | CW |
| 20 | Ausgang A | Zwangsführung | 2 Bit | 2.1 switch control | CW |
| 20 | Ausgang A | Zwangsführung | 1 Bit | 1.3 enable | CW |
| 21 | Ausgang A | Schwellwerteingang | 2 Bytes | 7.1 pulses | CW |
| 21 | Ausgang A | Schwellwerteingang | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 22 | Ausgang A | Schwellwert 1 ändern | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 22 | Ausgang A | Schwellwert 1 ändern | 2 Bytes | 7.1 pulses | CW |
| 23 | Dummy | Dummy | 1 Bit | 1.1 switch | |
| 24 | Dummy | Dummy | 1 Bit | 1.1 switch | |
| 29 | Ausgang A | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 30 | Ausgang B | Stellwert (PWM) | 1 Byte | 5.1 percentage (0..100%) | CW |
| 30 | Ausgang B | Schalten | 1 Bit | 1.1 switch | CW |
| 31 | Ausgang B | Ventilspülung auslösen | 1 Bit | 1.1 switch | CW |
| 31 | Ausgang B | Dauer-EIN | 1 Bit | 1.1 switch | CW |
| 32 | Ausgang B | Status Ventilspülung | 1 Bit | 1.2 boolean | CT |
| 32 | Ausgang B | Zeitfunktion sperren | 1 Bit | 1.3 enable | CW |
| 33 | Ausgang B | Störung RTR | 1 Bit | CT | |
| 33 | Ausgang B | Treppenlicht Zeitdauer | 2 Bytes | 7.1 pulses | CRW |
| 34 | Ausgang B | Zwangsführung | 1 Bit | 1.3 enable | CW |
| 34 | Ausgang B | Treppenlicht vorwarnen | 1 Bit | CT | |
| 35 | Ausgang B | Status Heizen | 1 Byte | 5.1 percentage (0..100%) | CT |
| 35 | Ausgang B | Status Heizen | 1 Bit | 1.1 switch | CT |
| 35 | Ausgang B | Preset 1/2 aufrufen | 1 Bit | CW | |
| 36 | Ausgang B | Preset 1/2 setzen | 1 Bit | CW | |
| 37 | Ausgang B | 8-Bit-Szene | 1 Byte | CW | |
| 38 | Ausgang B | Log. Verknüpfung 1 | 1 Bit | 1.2 boolean | CW |
| 39 | Ausgang B | Log. Verknüpfung 2 | 1 Bit | 1.2 boolean | CW |
| 40 | Ausgang B | Zwangsführung | 2 Bit | 2.1 switch control | CW |
| 40 | Ausgang B | Zwangsführung | 1 Bit | 1.3 enable | CW |
| 41 | Ausgang B | Schwellwerteingang | 2 Bytes | 7.1 pulses | CW |
| 41 | Ausgang B | Schwellwerteingang | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 42 | Ausgang B | Schwellwert 1 ändern | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 42 | Ausgang B | Schwellwert 1 ändern | 2 Bytes | 7.1 pulses | CW |
| 43 | Dummy | Dummy | 1 Bit | 1.1 switch | |
| 44 | Dummy | Dummy | 1 Bit | 1.1 switch | |
| 49 | Ausgang B | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 50 | Ausgang C | Stellwert (PWM) | 1 Byte | 5.1 percentage (0..100%) | CW |
| 50 | Ausgang C | Schalten | 1 Bit | 1.1 switch | CW |
| 51 | Ausgang C | Ventilspülung auslösen | 1 Bit | 1.1 switch | CW |
| 51 | Ausgang C | Dauer-EIN | 1 Bit | 1.1 switch | CW |
| 52 | Ausgang C | Status Ventilspülung | 1 Bit | 1.2 boolean | CT |
| 52 | Ausgang C | Zeitfunktion sperren | 1 Bit | 1.3 enable | CW |
| 53 | Ausgang C | Störung RTR | 1 Bit | CT | |
| 53 | Ausgang C | Treppenlicht Zeitdauer | 2 Bytes | 7.1 pulses | CRW |
| 54 | Ausgang C | Zwangsführung | 1 Bit | 1.3 enable | CW |
| 54 | Ausgang C | Treppenlicht vorwarnen | 1 Bit | CT | |
| 55 | Ausgang C | Status Heizen | 1 Byte | 5.1 percentage (0..100%) | CT |
| 55 | Ausgang C | Status Heizen | 1 Bit | 1.1 switch | CT |
| 55 | Ausgang C | Preset 1/2 aufrufen | 1 Bit | CW | |
| 56 | Ausgang C | Preset 1/2 setzen | 1 Bit | CW | |
| 57 | Ausgang C | 8-Bit-Szene | 1 Byte | CW | |
| 58 | Ausgang C | Log. Verknüpfung 1 | 1 Bit | 1.2 boolean | CW |
| 59 | Ausgang C | Log. Verknüpfung 2 | 1 Bit | 1.2 boolean | CW |
| 60 | Ausgang C | Zwangsführung | 2 Bit | 2.1 switch control | CW |
| 60 | Ausgang C | Zwangsführung | 1 Bit | 1.3 enable | CW |
| 61 | Ausgang C | Schwellwerteingang | 2 Bytes | 7.1 pulses | CW |
| 61 | Ausgang C | Schwellwerteingang | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 62 | Ausgang C | Schwellwert 1 ändern | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 62 | Ausgang C | Schwellwert 1 ändern | 2 Bytes | 7.1 pulses | CW |
| 63 | Dummy | Dummy | 1 Bit | 1.1 switch | |
| 64 | Dummy | Dummy | 1 Bit | 1.1 switch | |
| 69 | Ausgang C | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 70 | Ausgang D | Schalten | 1 Bit | 1.1 switch | CW |
| 70 | Ausgang D | Stellwert (PWM) | 1 Byte | 5.1 percentage (0..100%) | CW |
| 71 | Ausgang D | Dauer-EIN | 1 Bit | 1.1 switch | CW |
| 71 | Ausgang D | Ventilspülung auslösen | 1 Bit | 1.1 switch | CW |
| 72 | Ausgang D | Zeitfunktion sperren | 1 Bit | 1.3 enable | CW |
| 72 | Ausgang D | Status Ventilspülung | 1 Bit | 1.2 boolean | CT |
| 73 | Ausgang D | Treppenlicht Zeitdauer | 2 Bytes | 7.1 pulses | CRW |
| 73 | Ausgang D | Störung RTR | 1 Bit | CT | |
| 74 | Ausgang D | Treppenlicht vorwarnen | 1 Bit | CT | |
| 74 | Ausgang D | Zwangsführung | 1 Bit | 1.3 enable | CW |
| 75 | Ausgang D | Preset 1/2 aufrufen | 1 Bit | CW | |
| 75 | Ausgang D | Status Heizen | 1 Byte | 5.1 percentage (0..100%) | CT |
| 75 | Ausgang D | Status Heizen | 1 Bit | 1.1 switch | CT |
| 76 | Ausgang D | Preset 1/2 setzen | 1 Bit | CW | |
| 77 | Ausgang D | 8-Bit-Szene | 1 Byte | CW | |
| 78 | Ausgang D | Log. Verknüpfung 1 | 1 Bit | 1.2 boolean | CW |
| 79 | Ausgang D | Log. Verknüpfung 2 | 1 Bit | 1.2 boolean | CW |
| 80 | Ausgang D | Zwangsführung | 2 Bit | 2.1 switch control | CW |
| 80 | Ausgang D | Zwangsführung | 1 Bit | 1.3 enable | CW |
| 81 | Ausgang D | Schwellwerteingang | 2 Bytes | 7.1 pulses | CW |
| 81 | Ausgang D | Schwellwerteingang | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 82 | Ausgang D | Schwellwert 1 ändern | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 82 | Ausgang D | Schwellwert 1 ändern | 2 Bytes | 7.1 pulses | CW |
| 83 | Dummy | Dummy | 1 Bit | 1.1 switch | |
| 84 | Dummy | Dummy | 1 Bit | 1.1 switch | |
| 89 | Ausgang D | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 90 | Ausgang E | Schalten | 1 Bit | 1.1 switch | CW |
| 90 | Ausgang E | Stellwert (PWM) | 1 Byte | 5.1 percentage (0..100%) | CW |
| 91 | Ausgang E | Ventilspülung auslösen | 1 Bit | 1.1 switch | CW |
| 91 | Ausgang E | Dauer-EIN | 1 Bit | 1.1 switch | CW |
| 92 | Ausgang E | Zeitfunktion sperren | 1 Bit | 1.3 enable | CW |
| 92 | Ausgang E | Status Ventilspülung | 1 Bit | 1.2 boolean | CT |
| 93 | Ausgang E | Treppenlicht Zeitdauer | 2 Bytes | 7.1 pulses | CRW |
| 93 | Ausgang E | Störung RTR | 1 Bit | CT | |
| 94 | Ausgang E | Treppenlicht vorwarnen | 1 Bit | CT | |
| 94 | Ausgang E | Zwangsführung | 1 Bit | 1.3 enable | CW |
| 95 | Ausgang E | Preset 1/2 aufrufen | 1 Bit | CW | |
| 95 | Ausgang E | Status Heizen | 1 Bit | 1.1 switch | CT |
| 95 | Ausgang E | Status Heizen | 1 Byte | 5.1 percentage (0..100%) | CT |
| 96 | Ausgang E | Preset 1/2 setzen | 1 Bit | CW | |
| 97 | Ausgang E | 8-Bit-Szene | 1 Byte | CW | |
| 98 | Ausgang E | Log. Verknüpfung 1 | 1 Bit | 1.2 boolean | CW |
| 99 | Ausgang E | Log. Verknüpfung 2 | 1 Bit | 1.2 boolean | CW |
| 100 | Ausgang E | Zwangsführung | 2 Bit | 2.1 switch control | CW |
| 100 | Ausgang E | Zwangsführung | 1 Bit | 1.3 enable | CW |
| 101 | Ausgang E | Schwellwerteingang | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 101 | Ausgang E | Schwellwerteingang | 2 Bytes | 7.1 pulses | CW |
| 102 | Ausgang E | Schwellwert 1 ändern | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 102 | Ausgang E | Schwellwert 1 ändern | 2 Bytes | 7.1 pulses | CW |
| 103 | Dummy | Dummy | 1 Bit | 1.1 switch | |
| 104 | Dummy | Dummy | 1 Bit | 1.1 switch | |
| 109 | Ausgang E | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 110 | Ausgang F | Stellwert (PWM) | 1 Byte | 5.1 percentage (0..100%) | CW |
| 110 | Ausgang F | Schalten | 1 Bit | 1.1 switch | CW |
| 111 | Ausgang F | Ventilspülung auslösen | 1 Bit | 1.1 switch | CW |
| 111 | Ausgang F | Dauer-EIN | 1 Bit | 1.1 switch | CW |
| 112 | Ausgang F | Status Ventilspülung | 1 Bit | 1.2 boolean | CT |
| 112 | Ausgang F | Zeitfunktion sperren | 1 Bit | 1.3 enable | CW |
| 113 | Ausgang F | Störung RTR | 1 Bit | CT | |
| 113 | Ausgang F | Treppenlicht Zeitdauer | 2 Bytes | 7.1 pulses | CRW |
| 114 | Ausgang F | Zwangsführung | 1 Bit | 1.3 enable | CW |
| 114 | Ausgang F | Treppenlicht vorwarnen | 1 Bit | CT | |
| 115 | Ausgang F | Status Heizen | 1 Byte | 5.1 percentage (0..100%) | CT |
| 115 | Ausgang F | Status Heizen | 1 Bit | 1.1 switch | CT |
| 115 | Ausgang F | Preset 1/2 aufrufen | 1 Bit | CW | |
| 116 | Ausgang F | Preset 1/2 setzen | 1 Bit | CW | |
| 117 | Ausgang F | 8-Bit-Szene | 1 Byte | CW | |
| 118 | Ausgang F | Log. Verknüpfung 1 | 1 Bit | 1.2 boolean | CW |
| 119 | Ausgang F | Log. Verknüpfung 2 | 1 Bit | 1.2 boolean | CW |
| 120 | Ausgang F | Zwangsführung | 2 Bit | 2.1 switch control | CW |
| 120 | Ausgang F | Zwangsführung | 1 Bit | 1.3 enable | CW |
| 121 | Ausgang F | Schwellwerteingang | 2 Bytes | 7.1 pulses | CW |
| 121 | Ausgang F | Schwellwerteingang | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 122 | Ausgang F | Schwellwert 1 ändern | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 122 | Ausgang F | Schwellwert 1 ändern | 2 Bytes | 7.1 pulses | CW |
| 123 | Dummy | Dummy | 1 Bit | 1.1 switch | |
| 124 | Dummy | Dummy | 1 Bit | 1.1 switch | |
| 129 | Ausgang F | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 130 | Ausgang G | Stellwert (PWM) | 1 Byte | 5.1 percentage (0..100%) | CW |
| 130 | Ausgang G | Schalten | 1 Bit | 1.1 switch | CW |
| 131 | Ausgang G | Ventilspülung auslösen | 1 Bit | 1.1 switch | CW |
| 131 | Ausgang G | Dauer-EIN | 1 Bit | 1.1 switch | CW |
| 132 | Ausgang G | Status Ventilspülung | 1 Bit | 1.2 boolean | CT |
| 132 | Ausgang G | Zeitfunktion sperren | 1 Bit | 1.3 enable | CW |
| 133 | Ausgang G | Störung RTR | 1 Bit | CT | |
| 133 | Ausgang G | Treppenlicht Zeitdauer | 2 Bytes | 7.1 pulses | CRW |
| 134 | Ausgang G | Zwangsführung | 1 Bit | 1.3 enable | CW |
| 134 | Ausgang G | Treppenlicht vorwarnen | 1 Bit | CT | |
| 135 | Ausgang G | Status Heizen | 1 Byte | 5.1 percentage (0..100%) | CT |
| 135 | Ausgang G | Status Heizen | 1 Bit | 1.1 switch | CT |
| 135 | Ausgang G | Preset 1/2 aufrufen | 1 Bit | CW | |
| 136 | Ausgang G | Preset 1/2 setzen | 1 Bit | CW | |
| 137 | Ausgang G | 8-Bit-Szene | 1 Byte | CW | |
| 138 | Ausgang G | Log. Verknüpfung 1 | 1 Bit | 1.2 boolean | CW |
| 139 | Ausgang G | Log. Verknüpfung 2 | 1 Bit | 1.2 boolean | CW |
| 140 | Ausgang G | Zwangsführung | 2 Bit | 2.1 switch control | CW |
| 140 | Ausgang G | Zwangsführung | 1 Bit | 1.3 enable | CW |
| 141 | Ausgang G | Schwellwerteingang | 2 Bytes | 7.1 pulses | CW |
| 141 | Ausgang G | Schwellwerteingang | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 142 | Ausgang G | Schwellwert 1 ändern | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 142 | Ausgang G | Schwellwert 1 ändern | 2 Bytes | 7.1 pulses | CW |
| 143 | Dummy | Dummy | 1 Bit | 1.1 switch | |
| 144 | Dummy | Dummy | 1 Bit | 1.1 switch | |
| 149 | Ausgang G | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 150 | Ausgang H | Stellwert (PWM) | 1 Byte | 5.1 percentage (0..100%) | CW |
| 150 | Ausgang H | Schalten | 1 Bit | 1.1 switch | CW |
| 151 | Ausgang H | Ventilspülung auslösen | 1 Bit | 1.1 switch | CW |
| 151 | Ausgang H | Dauer-EIN | 1 Bit | 1.1 switch | CW |
| 152 | Ausgang H | Status Ventilspülung | 1 Bit | 1.2 boolean | CT |
| 152 | Ausgang H | Zeitfunktion sperren | 1 Bit | 1.3 enable | CW |
| 153 | Ausgang H | Störung RTR | 1 Bit | CT | |
| 153 | Ausgang H | Treppenlicht Zeitdauer | 2 Bytes | 7.1 pulses | CRW |
| 154 | Ausgang H | Zwangsführung | 1 Bit | 1.3 enable | CW |
| 154 | Ausgang H | Treppenlicht vorwarnen | 1 Bit | CT | |
| 155 | Ausgang H | Status Heizen | 1 Byte | 5.1 percentage (0..100%) | CT |
| 155 | Ausgang H | Status Heizen | 1 Bit | 1.1 switch | CT |
| 155 | Ausgang H | Preset 1/2 aufrufen | 1 Bit | CW | |
| 156 | Ausgang H | Preset 1/2 setzen | 1 Bit | CW | |
| 157 | Ausgang H | 8-Bit-Szene | 1 Byte | CW | |
| 158 | Ausgang H | Log. Verknüpfung 1 | 1 Bit | 1.2 boolean | CW |
| 159 | Ausgang H | Log. Verknüpfung 2 | 1 Bit | 1.2 boolean | CW |
| 160 | Ausgang H | Zwangsführung | 2 Bit | 2.1 switch control | CW |
| 160 | Ausgang H | Zwangsführung | 1 Bit | 1.3 enable | CW |
| 161 | Ausgang H | Schwellwerteingang | 2 Bytes | 7.1 pulses | CW |
| 161 | Ausgang H | Schwellwerteingang | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 162 | Ausgang H | Schwellwert 1 ändern | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 162 | Ausgang H | Schwellwert 1 ändern | 2 Bytes | 7.1 pulses | CW |
| 163 | Dummy | Dummy | 1 Bit | 1.1 switch | |
| 164 | Dummy | Dummy | 1 Bit | 1.1 switch | |
| 169 | Ausgang H | Status Schalten | 1 Bit | 1.1 switch | CRT |
Parameters (99)
| Parameter | Type | Default |
|---|---|---|
| Sende- und Schaltverzögerung nach Busspannungswiederkehr (2...255s) | unsignedInt 2…255 | 2 |
| Telegrammrate_Zeittics 59 = 1sec | unsignedInt 0…255 | 59 |
| Zyklisch "In Betrieb" Telegramm senden (0...65.535s, 0 = senden inaktiv) | unsignedInt 0…65535 | 0 |
| Gerätesicherheitsobjekte für Betriebsart "Schaltaktor" freischalten | list | nein |
| Hinweis: Aktion des Ausgangs auf "Funktion Sicherheit Priorität x" | list | Einstellung im Parameterfenster "X: Sicherheit" |
| Funktion Sicherheit Priorität 1 | list | inaktiv |
| Überwachungszeit in Sekunden (0...65.535, 0 = inaktiv) | unsignedInt 0…65535 | 0 |
| Funktion Sicherheit Priorität 2 | list | inaktiv |
| Funktion Sicherheit Priorität 3 | list | inaktiv |
| Betriebsart des Ausgangs | list | Schaltaktor |
| Rückmeldung des Schaltzustandes über Objekt "Status Schalten" | list | bei Änderung |
| Objektwert Schaltzustand (Objekt "Status Schalten") | list | 1=geschlossen, 0=geöffnet |
| Verhalten bei Busspannungsausfall | list | Kontakt unverändert |
| Angeschlossener Ventiltyp | list | stromlos geschlossen |
| Ansteuerung wird empfangen als | list | 1-Bit (PWM oder 2-punkt) |
| Rückmeldung des Regelwert über Objekt "Status Heizen" | list | nein |
| Wert des Objekts "Schalten" bei Busspannungswiederkehr | list | nicht beschreiben |
| Szenen, Presets und Schwellwert 1 beim Download überschreiben | list | ja |
| PWM-Zykluszeit für stetige Ansteuerung Minuten (3...65.535) | unsignedInt 3…65535 | 10 |
| PWM-Zykluszeit für stetige Ansteuerung Sekunden (0...59) | unsignedInt 0…59 | 0 |
| Position des Ventilantriebs bei Busspannungswiederkehr | list | 0% (geschlossen) |
| Funktion Überwachung des Reglers freigeben | list | nein |
| Funktion Zwangsführung freigeben | list | nein |
| Verhalten des Ausgangs | list | Schließer |
| Funktion Ventilspülung freigeben | list | nein |
| Funktion Zeit: Verzögerung, Treppenlicht Blinken freigeben | list | nein |
| Wert des Objekts "Zeitfunktion sperren" bei Busspannungswiederkehr | list | "0", d.h. Zeitfunktion freigeben |
| Funktion Preset freigeben | list | nein |
| Funktion Szene (8 Bit) freigeben | list | nein |
| Funktion Verknüpfung/Logik freigeben | list | nein |
| Funktion Sicherheit freigeben | list | nein |
| Funktion Schwellwert freigeben | list | nein |
| Objekt Schalten nach BW | list | nicht beschreiben |
| Zeitfunktion | list | Treppenlichtfunktion |
| in Sekunden (0...59) | unsignedInt 0…59 | 0 |
| Blinken wenn Objekt "Schalten" gleich | list | EIN (1) oder AUS (0) |
| in Minuten (0...65.535) | unsignedInt 0…65535 | 60 |
| Treppenlicht Zeitdauer: Minuten (0...1000) | unsignedInt 0…1000 | 5 |
| Einschaltverzögerung: Min. (0...65.535) | unsignedInt 0…65535 | 0 |
| Zeitdauer für EIN: Min. (0...65.535) | unsignedInt 0…65535 | 0 |
| Sekunden (0...59) | unsignedInt 0…59 | 0 |
| Einschaltverzögerung: Sek. (0...59) | unsignedInt 0…59 | 0 |
| Zeitdauer für EIN: Sek. (1...59) | unsignedInt 1…59 | 5 |
| Position des Ventilantriebs bei Ausfall des Reglers | list | unverändert |
| Zeitdauer für AUS: Min. (0...65.535) | unsignedInt 0…65535 | 0 |
| Ausschaltverzögerung: Min. (0...65.535) | unsignedInt 0…65535 | 0 |
| Ausschaltverzögerung: Sek. (0...59) | unsignedInt 0…59 | 0 |
| Zeitdauer für AUS: Sek. (1...59) | unsignedInt 1…59 | 5 |
| Objekt "Störung RTR" freigeben | list | nein |
| Anzahl der Impulse: (1...100) | unsignedInt 1…100 | 5 |
| Treppenlichtzeit verlängert sich bei mehrfachem Einschalten ("Pumpen") | list | ja (retriggerbar) |
| Zustand des Schaltkontakts nach dem Blinken | list | aktualisiert Schaltzustand |
| Treppenlicht schaltbar | list | EIN mit "1" und AUS mit "0" |
| Warnung vor Auslauf des Treppenlichts | list | durch Kommunikationsobjekt |
| Warnzeit in Sekunden (0...65.535) verlängert Treppenlicht Zeitdauer | unsignedInt 0…65535 | 45 |
| Ventilstellung während Zwangsführung | list | unverändert |
| Treppenlicht Zeitdauer über Objekt "Treppenlicht Zeitdauer" ändern | list | nein |
| Nach Beendigung von Dauer-EIN startet Treppenlicht neu | list | nein |
| Hinweis: Kontaktlebensdauer und Schalt- spiele pro Minute sind zu beachten | list | Weitere Hinweise, siehe Produkt-Handbuch |
| Dauer der Ventilspülung in Minuten (0...255) | unsignedInt 0…255 | 10 |
| Automatische Spülung | list | nein |
| Automatische Spülung | unsignedInt 0…65000 | 0 |
| Verh. bei Preset 1 (Telegrammwert 0) | list | keine Reaktion |
| Verh. bei Preset 2 (Telegrammwert 1) | list | keine Reaktion |
| Preset über Bus setzen | list | ja |
| Ausgang zuordnen zu (Szene 1...64) | list | keiner Szene |
| Standardwert | list | EIN |
| Ausgang zugeodnet zu (Szene 1...64) | list | keiner Szene |
| Verknüpfungsobjekt 1 | list | inaktiv |
| Funktion von Verknüpfungsobjekt 1 | list | UND |
| Tor sperrt, wenn Objektwert "Log. Verknüpfung 1" gleich | list | 0 |
| Ergebnis invertieren | list | nein |
| Objektwert "Log. Verknüpfung 1" nach Busspannungswiederkehr | list | 0 |
| Verknüpfungsobjekt 2 | list | inaktiv |
| Funktion von Verknüpfungsobjekt 2 | list | UND |
| Tor sperrt, wenn Objektwert "Log. Verknüpfung 2" gleich | list | 0 |
| Objektwert "Log. Verknüpfung 2" bei Busspannungswiederkehr | list | 0 |
| Aktivierung "Sicherheit Priorität x" | list | auf Parameterfenster "Allgemein" |
| Schaltzustand bei Sicherheit Priorität 1 | list | inaktiv |
| Schaltzustand bei Zwangsführung | list | inaktiv |
| Objektwert "Zwangsführung" bei Busspannungswiederkehr | list | inaktiv |
| Objektwert "Zwangsführung" bei Busspannungswiederkehr | list | "0" inaktiv |
| Schaltzustand bei Sicherheit Priorität 2 | list | inaktiv |
| Schaltzustand bei Sicherheit Priorität 3 | list | inaktiv |
| Schaltzustand bei Ende der Zwangsführung und aller Sicherheits Prioritäten | list | aktualisiert Schaltzustand |
| Datentyp Objekt "Schwellwerteingang" | list | 1 Byte (0...255) |
| Schwellwert (SW) 1 über Bus ändern | list | nein |
| Schwellwert 1 (0...65.535) | unsignedInt 0…65535 | 20000 |
| Schwellwert 1 (0...255) | unsignedInt 0…255 | 80 |
| Schwellwert 2 (0...255) | unsignedInt 0…255 | 160 |
| Schwellwert 2 (0...65.535) | unsignedInt 0…65535 | 40000 |
| Schwellwerte sind Hysteresegrenzen | list | ja |
| Unterschreiten des unteren SW | list | unverändert |
| Objektwert < unterer Schwellwert | list | unverändert |
| Unterer SW <= Objektwert <= Oberer SW | list | unverändert |
| Objektwert > Oberer Schwellwert | list | unverändert |
| Überschreiten des oberen SW | list | unverändert |
| Objektwert "Schwellwerteingang" nach Busspannungswiederkehr (0...255) | unsignedInt 0…255 | 0 |
| Objektwert "Schwellwerteingang" nach Busspannungswiederkehr (0...65.535) | unsignedInt 0…65535 | 0 |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Switch 8f 6A/3.2 3.2 latest | $A089 | B898 | 2026-11-25 | 497 KB | Download |
About this file
This is the official ETS product database for the ABB AG - BUSCH-JAEGER SA/S8.6.1.1 Switch Actuator,8-fold,6A,MDRC (6195/31), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from ABB AG - BUSCH-JAEGER
- 6151/11 Switching act. 1gang w/ bin. Inputs 6151/11 U
- 6194/11-101 Binärausgang,2f,16/20A,Stromerk.,REG 6194/11-101
- 6194/12-101 Binärausgang,4f, 16/20A,Stromerk.,REG 6194/12-101
- 6194/13-101 Binärausgang,8f,16/20A,Stromerk.,REG 6194/13-101
- 6194/14-101 Binärausgang,12f,16/20A,C-Last,REG 6194/14-101
- 6194/18 Binärausgang 12f,16/20A,Stromerk.,REG 6194/18
- 6194/20 Binärausgang,2f,16/20A,C-Last,REG 6194/20
- 6194/21 Binärausgang,4f,16/20A,C-Last,REG 6194/21
- 6194/22 Binärausgang,4f,16/20A,C-Last,REG 6194/22
- SA/S2.16.2.1 Switch Actuator,2-fold,16A,MDRC 6194/25
- SA/S4.16.2.1 Switch Actuator,4-fold,16A,MDRC 6194/26
- SA/S8.16.2.1 Switch Actuator,8-fold,16A,MDRC 6194/27