6194/20 Binärausgang,2f,16/20A,C-Last,REG 6194/20

ABB AG - BUSCH-JAEGER · Order number 6194/20 · Output › Binary output, 2-fold

Download .knxprod Switch 2f 16C/3.2 3.2 · 450 KB

Product

ManufacturerABB AG - BUSCH-JAEGER
Product name6194/20 Binärausgang,2f,16/20A,C-Last,REG
Order number6194/20
HardwareSA/S2.16.5.1
MediumTwisted Pair
Bus current (mA)12
Rail mountedYes
Width (mm)36
RegistrationRegistered
Languagesde-DE
Catalog entryM-0007_H-2CDG.20110.20132.20R0011-1-O0002_HP-A069-32-916C-O0002_CI-6194.2F20-1
Fingerprint916C
SHA-25616368af41bab4c3e90c9a32b08cfdacd7b3bd176d546f6a2b71621ae3b77cf63
First seen2026-11-25
MarketsAustralia

Application program: Switch 2f 16C/3.2 3.2

Application number$A069
Version3.2
Mask versionMV-0701 (7.1)
KNX Data SecureNo
Parameters294
Group objects72
Group objects (72)
NoNameFunctionSizeDPTFlags
0GeneralIn Operation1 BitCRT
1GeneralSafety Priority 11 BitCWU
2GeneralSafety Priority 21 BitCWU
3GeneralSafety Priority 31 BitCWU
4xDummy1 Bit
5xDummy1 Bit
6xDummy1 Bit
7xDummy1 Bit
8xDummy1 Bit
9xDummy1 Bit
10Output AControl value (PWM)1 ByteCW
10Output Aswitch1 BitCW
10Output ASwitch1 BitCW
11Output ATrigger valve purge1 BitCW
11Output APermanent ON1 BitCW
12Output AStatus valve purge1 BitCT
12Output ADisable time function1 BitCW
13Output ARTR fault1 BitCT
13Output ADuration of staircase lighting2 BytesCRW
14Output AForced operation1 BitCW
14Output Awarning stair lighting1 BitCT
15Output AStatus heating1 ByteCT
15Output AStatus heating1 BitCT
15Output ACall preset 1/21 BitCW
16Output ASet preset 1/21 BitCW
17Output A8 bit scene1 ByteCW
18Output ALogical connection 11 BitCW
19Output ALogical connection 21 BitCW
20Output AForced Positioning2 BitCW
20Output AForced Positioning1 BitCW
21Output AThreshold input2 BytesCW
21Output AThreshold input1 ByteCW
22Output AChange Threshold value 11 ByteCW
22Output AChange Threshold value 12 BytesCW
23xDummy1 Bit
24xDummy1 Bit
25Output AContact monitoring1 BitCT
26Output ACurrent Value4 BytesCRT
27Output AStatus Current-Threshold 11 BitCT
28Output AStatus Current-Threshold 21 BitCT
29Output AStatus Switch1 BitCRT
30Output BControl value (PWM)1 ByteCW
30Output Bswitch1 BitCW
30Output BSwitch1 BitCW
31Output BTrigger valve purge1 BitCW
31Output BPermanent ON1 BitCW
32Output BStatus valve purge1 BitCT
32Output BDisable time function1 BitCW
33Output BRTR fault1 BitCT
33Output BDuration of staircase lighting2 BytesCRW
34Output BForced operation1 BitCW
34Output Bwarning stair lighting1 BitCT
35Output BStatus heating1 ByteCT
35Output BStatus heating1 BitCT
35Output BCall preset 1/21 BitCW
36Output BSet preset 1/21 BitCW
37Output B8 bit scene1 ByteCW
38Output BLogical connection 11 BitCW
39Output BLogical connection 21 BitCW
40Output BForced Positioning2 BitCW
40Output BForced Positioning1 BitCW
41Output BThreshold input2 BytesCW
41Output BThreshold input1 ByteCW
42Output BChange Threshold value 11 ByteCW
42Output BChange Threshold value 12 BytesCW
43xDummy1 Bit
44xDummy1 Bit
45Output BContact monitoring1 BitCT
46Output BCurrent Value2 BytesCRT
47Output BStatus Current-Threshold 11 BitCT
48Output BStatus Current-Threshold 21 BitCT
49Output BStatus Switch1 BitCRT
Parameters (101)
ParameterTypeDefault
Transmission and switching delay after recovery of bus voltage (2...255s)unsignedInt 2…2552
Rate of telegramslistnot limited
Rate of telegramsunsignedInt 0…25559
Send cyclical "In operation" telegram (0...65.535s, 0 = inactive)unsignedInt 0…655350
Enable Safety Object for operating mode "Switch Actuator"listno
Remark: Reaction of output on "Function Safety Priority x"listis set on parameter-window "X: Safety"
Function Safety Priority 1listinactive
Control period in seconds (0...65.535, 0 = inactive)unsignedInt 0…655350
Function Safety Priority 2listinactive
Function Safety Priority 3listinactive
Operating mode of output AlistSwitch Actuator
Status response of switching state Object "Status Switch"listonly after changing
Object value switching status (Object "Status Switch")list1=closed, 0=open
Reaction on bus voltage failurelistContact unchanged
Connected valve typelistnormally closed
Control telegram is received aslist1 bit (PWM or on-off control)
Transmit status response Object "Status heating"listno
Value object "Switch" on bus voltage recoverylistnot write
Overwrite scene, preset and threshold value 1 with downloadlistyes
PWM-cycle time for continuous control Minutes (3...65.535)unsignedInt 3…6553510
PWM-cycle time for continuous control Seconds (0...59)unsignedInt 0…590
Position of the valve drive on bus voltage recoverylist0% (closed)
Enable monitoring of the controllerlistno
Enable function "forced operation"listno
Reaction of output AlistNormally open contact
Enable function "valve purge"listno
Enable time functions "delay, staircase lighting, flashing"listno
Value object "Disable Time Function" after bus voltage recoverylist"0", enable time functions
Enable function "presets"listno
Enable function "scene (8 bit)"listno
Enable function "logic"listno
Enable functions "priority and safety operation"listno
Enable function "threshold"listno
Enable function "current detection"listno
State without functionlistnot write
Time functionlistStaircase lighting function
in seconds (0...59)unsignedInt 0…590
Flashing if object "Switching" islistalways flashing, ON (1) or OFF (0)
in minutes (0...65.535)unsignedInt 0…6553560
Duration of staircase lighting Minutes (0...1000)unsignedInt 0…10005
Delay for switching on: (Min.(0...65535)unsignedInt 0…655350
Time for ON: Min. (0...65.535)unsignedInt 0…655350
Seconds (0...59)unsignedInt 0…590
Delay for switching on: Sec. (0...59)unsignedInt 0…590
Time for ON: Sec. (1...59)unsignedInt 1…595
Position of the valve drive during fault of room thermostatlistunchanged
Time for OFF: Min. (0...65.535)unsignedInt 0…655350
Delay for switching OFF: Min. (0...65.53unsignedInt 0…655350
Delay for switching OFF: Sec. (0...59)unsignedInt 0…590
Time for OFF: Sec. (1...59)unsignedInt 1…595
Enable object "RTR fault"listno
Number of ON-impulses: (1...100)unsignedInt 1…1005
Extending staircase lighting by multiple operation ("pumping up")listyes (retriggerable)
Contact position after flashinglistcalculate present contact position
Staircase lighting can be switched offlistON with "1" and OFF with "0"
Warning before end of staircase lightinglistvia object
Warning time in sec. (0...65.535) add to duration of staircase lightingunsignedInt 0…6553545
Valve position during forced positioninglistunchanged
Duration of staircase lighting can be changed by objectlistno
Restart of staircase time after end of permanent ONlistno
Note: Observe contact life and switching frequency per minutelistsee technical data
Time of valve purge in minutes (0...255)unsignedInt 0…25510
Automatic valve purgelistdisable
Automatic valve purgeunsignedInt 0…650000
Reaction on preset 1 (telegr. value 0)listno reaction
Reaction on preset 2 (telegr. value 1)listno reaction
Preset can be set via the buslistyes
Output is assigned to (Scene 1...64)listno allocation
Standard valuelistON
Logical Connection 1listdisable
Function of object "Logical connection2"listAND
Gate disabled, if Object value "Logical connection 1" islist"0"
Result is invertedlistno
Object value "Logical connection 1" after bus voltage recoverylist"0"
Logical Connection 2listdisable
Gate disabled, if Object value "Logical connection 2" islist"0"
Object value "Logical connection 2" after bus voltage recoverylist"0"
Enable "Safety Priority x"liston parameter-window "General"
Contact position if Safety Priority 1listinactive
Contact position if forced operationlistinactive
Object value "Forced positioning" on bus voltage recoverylistdisable
Object value "Forced positioning" on bus voltage recoverylist"0" inactive
Contact position if Safety Priority 2listinactive
Contact position if Safety Priority 3listinactive
Reaction when forced operation and all Safety Priority x endlistcalculate present contact position
Data type of object "Threshold input"list1 byte (0...255)
Change Threshold 1 over buslistno
Threshold value 1 (0...65.535))unsignedInt 0…6553520000
Threshold value 1 (0...255)unsignedInt 0…25580
Threshold value 2 (0...255)unsignedInt 0…255160
Threshold value 2 (0...65.535)unsignedInt 0…6553540000
Threshold values define hysteresislistyes
Falling below lower thresholdlistno reaction
Object value < lower thresholdlistno reaction
Lower thrsh. <= object <= upper thrsh.listno reaction
Object value > lower thresholdlistno reaction
Exceeding upper thresholdlistno reaction
Object "threshold input" value on bus voltage recovery (0...255)unsignedInt 0…2550
Object "threshold input" value on bus voltage recovery (0...65.535)unsignedInt 0…655350
Operating mode of output BlistSwitch Actuator
Reaction of output BlistNormally open contact

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Switch 2f 16C/3.2 3.2 latest$A069916C2026-11-25450 KBDownload

About this file

This is the official ETS product database for the ABB AG - BUSCH-JAEGER 6194/20 Binärausgang,2f,16/20A,C-Last,REG (6194/20), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.