6194/11-101 Binärausgang,2f,16/20A,Stromerk.,REG 6194/11-101
ABB AG - BUSCH-JAEGER · Order number 6194/11-101 · Output › Binary output, 2-fold
Download .knxprod Switch 2f 16CS/3.2 3.2 · 475 KB
Product
| Manufacturer | ABB AG - BUSCH-JAEGER |
|---|---|
| Product name | 6194/11-101 Binärausgang,2f,16/20A,Stromerk.,REG |
| Order number | 6194/11-101 |
| Hardware | SA/S2.16.6.1 |
| Medium | Twisted Pair |
| Bus current (mA) | 12 |
| Rail mounted | Yes |
| Width (mm) | 36 |
| Registration | Registered |
| Languages | de-DE |
| Catalog entry | M-0007_H-2CDG.20110.20112.20R0011-2-O0002_HP-A05B-32-2C5D-O0002_CI-6194.2F11.2D101-1 |
| Fingerprint | 2C5D |
| SHA-256 | 4ba54d15701641ec5f218fcce0e2dfd436f90a05cf1a7b5f628bfcaafbe42a2a |
| First seen | 2026-11-25 |
| Markets | Australia |
Application program: Switch 2f 16CS/3.2 3.2
| Application number | $A05B |
|---|---|
| Version | 3.2 |
| Mask version | MV-0701 (7.1) |
| KNX Data Secure | No |
| Parameters | 628 |
| Group objects | 138 |
Group objects (138)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | General | In Operation | 1 Bit | CRT | |
| 1 | General | Safety Priority 1 | 1 Bit | CWU | |
| 2 | General | Safety Priority 2 | 1 Bit | CWU | |
| 3 | General | Safety Priority 3 | 1 Bit | CWU | |
| 4 | x | Dummy | 1 Bit | ||
| 5 | x | Dummy | 1 Bit | ||
| 6 | x | Dummy | 1 Bit | ||
| 7 | x | Dummy | 1 Bit | ||
| 8 | x | Dummy | 1 Bit | ||
| 9 | x | Dummy | 1 Bit | ||
| 10 | Output A | Control value (PWM) | 1 Byte | CW | |
| 10 | Output A | switch | 1 Bit | CW | |
| 10 | Output A | Switch | 1 Bit | CW | |
| 11 | Output A | Trigger valve purge | 1 Bit | CW | |
| 11 | Output A | Permanent ON | 1 Bit | CW | |
| 12 | Output A | Status valve purge | 1 Bit | CT | |
| 12 | Output A | Disable time function | 1 Bit | CW | |
| 13 | Output A | RTR fault | 1 Bit | CT | |
| 13 | Output A | Duration of staircase lighting | 2 Bytes | CRW | |
| 14 | Output A | Forced operation | 1 Bit | CW | |
| 14 | Output A | warning stair lighting | 1 Bit | CT | |
| 15 | Output A | Status heating | 1 Byte | CT | |
| 15 | Output A | Status heating | 1 Bit | CT | |
| 15 | Output A | Call preset 1/2 | 1 Bit | CW | |
| 16 | Output A | Set preset 1/2 | 1 Bit | CW | |
| 17 | Output A | 8 bit scene | 1 Byte | CW | |
| 18 | Output A | Logical connection 1 | 1 Bit | CW | |
| 19 | Output A | Logical connection 2 | 1 Bit | CW | |
| 20 | Output A | Forced Positioning | 2 Bit | CW | |
| 20 | Output A | Forced Positioning | 1 Bit | CW | |
| 21 | Output A | Threshold input | 2 Bytes | CW | |
| 21 | Output A | Threshold input | 1 Byte | CW | |
| 22 | Output A | Change Threshold value 1 | 1 Byte | CW | |
| 22 | Output A | Change Threshold value 1 | 2 Bytes | CW | |
| 23 | x | Dummy | 1 Bit | ||
| 24 | x | Dummy | 1 Bit | ||
| 25 | Output A | Contact monitoring | 1 Bit | CRT | |
| 26 | Output A | Current Value | 2 Bytes | CRT | |
| 26 | Output A | Current Value | 4 Bytes | CRT | |
| 27 | Output A | Status Current-Threshold 1 | 1 Bit | CT | |
| 28 | Output A | Status Current-Threshold 2 | 1 Bit | CT | |
| 29 | Output A | Status Switch | 1 Bit | CRT | |
| 30 | Output B | Control value (PWM) | 1 Byte | CW | |
| 30 | Output B | switch | 1 Bit | CW | |
| 30 | Output B | Switch | 1 Bit | CW | |
| 31 | Output B | Trigger valve purge | 1 Bit | CW | |
| 31 | Output B | Permanent ON | 1 Bit | CW | |
| 32 | Output B | Status valve purge | 1 Bit | CT | |
| 32 | Output B | Disable time function | 1 Bit | CW | |
| 33 | Output B | RTR fault | 1 Bit | CT | |
| 33 | Output B | Duration of staircase lighting | 2 Bytes | CRW | |
| 34 | Output B | Forced operation | 1 Bit | CW | |
| 34 | Output B | warning stair lighting | 1 Bit | CT | |
| 35 | Output B | Status heating | 1 Byte | CT | |
| 35 | Output B | Status heating | 1 Bit | CT | |
| 35 | Output B | Call preset 1/2 | 1 Bit | CW | |
| 36 | Output B | Set preset 1/2 | 1 Bit | CW | |
| 37 | Output B | 8 bit scene | 1 Byte | CW | |
| 38 | Output B | Logical connection 1 | 1 Bit | CW | |
| 39 | Output B | Logical connection 2 | 1 Bit | CW | |
| 40 | Output B | Forced Positioning | 2 Bit | CW | |
| 40 | Output B | Forced Positioning | 1 Bit | CW | |
| 41 | Output B | Threshold input | 2 Bytes | CW | |
| 41 | Output B | Threshold input | 1 Byte | CW | |
| 42 | Output B | Change Threshold value 1 | 1 Byte | CW | |
| 42 | Output B | Change Threshold value 1 | 2 Bytes | CW | |
| 43 | x | Dummy | 1 Bit | ||
| 44 | x | Dummy | 1 Bit | ||
| 45 | Output B | Contact monitoring | 1 Bit | CRT | |
| 46 | Output B | Current Value | 2 Bytes | CRT | |
| 46 | Output B | Current Value | 4 Bytes | CRT | |
| 47 | Output B | Status Current-Threshold 1 | 1 Bit | CT | |
| 48 | Output B | Status Current-Threshold 2 | 1 Bit | CT | |
| 49 | Output B | Status Switch | 1 Bit | CRT | |
| 50 | Output C | Control value (PWM) | 1 Byte | CW | |
| 50 | Output C | switch | 1 Bit | CW | |
| 50 | Output C | Switch | 1 Bit | CW | |
| 51 | Output C | Trigger valve purge | 1 Bit | CW | |
| 51 | Output C | Permanent ON | 1 Bit | CW | |
| 52 | Output C | Status valve purge | 1 Bit | CT | |
| 52 | Output C | Disable time function | 1 Bit | CW | |
| 53 | Output C | RTR fault | 1 Bit | CT | |
| 53 | Output C | Duration of staircase lighting | 2 Bytes | CRW | |
| 54 | Output C | Forced operation | 1 Bit | CW | |
| 54 | Output C | warning stair lighting | 1 Bit | CT | |
| 55 | Output C | Status heating | 1 Byte | CT | |
| 55 | Output C | Status heating | 1 Bit | CT | |
| 55 | Output C | Call preset 1/2 | 1 Bit | CW | |
| 56 | Output C | Set preset 1/2 | 1 Bit | CW | |
| 57 | Output C | 8 bit scene | 1 Byte | CW | |
| 58 | Output C | Logical connection 1 | 1 Bit | CW | |
| 59 | Output C | Logical connection 2 | 1 Bit | CW | |
| 60 | Output C | Forced Positioning | 2 Bit | CW | |
| 60 | Output C | Forced Positioning | 1 Bit | CW | |
| 61 | Output C | Threshold input | 2 Bytes | CW | |
| 61 | Output C | Threshold input | 1 Byte | CW | |
| 62 | Output C | Change Threshold value 1 | 1 Byte | CW | |
| 62 | Output C | Change Threshold value 1 | 2 Bytes | CW | |
| 63 | x | Dummy | 1 Bit | ||
| 64 | x | Dummy | 1 Bit | ||
| 65 | Output C | Contact monitoring | 1 Bit | CT | |
| 66 | Output C | Current Value | 2 Bytes | CRT | |
| 66 | Output C | Current Value | 4 Bytes | CRT | |
| 67 | Output C | Status Current-Threshold 1 | 1 Bit | CT | |
| 68 | Output C | Status Current-Threshold 2 | 1 Bit | CT | |
| 69 | Output C | Status Switch | 1 Bit | CRT | |
| 70 | Output D | Switch | 1 Bit | CW | |
| 70 | Output D | switch | 1 Bit | CW | |
| 70 | Output D | Control value (PWM) | 1 Byte | CW | |
| 71 | Output D | Permanent ON | 1 Bit | CW | |
| 71 | Output D | Trigger valve purge | 1 Bit | CW | |
| 72 | Output D | Disable time function | 1 Bit | CW | |
| 72 | Output D | Status valve purge | 1 Bit | CT | |
| 73 | Output D | Duration of staircase lighting | 2 Bytes | CRW | |
| 73 | Output D | RTR fault | 1 Bit | CT | |
| 74 | Output D | warning stair lighting | 1 Bit | CT | |
| 74 | Output D | Forced operation | 1 Bit | CW | |
| 75 | Output D | Call preset 1/2 | 1 Bit | CW | |
| 75 | Output D | Status heating | 1 Byte | CT | |
| 75 | Output D | Status heating | 1 Bit | CT | |
| 76 | Output D | Set preset 1/2 | 1 Bit | CW | |
| 77 | Output D | 8 bit scene | 1 Byte | CW | |
| 78 | Output D | Logical connection 1 | 1 Bit | CW | |
| 79 | Output D | Logical connection 2 | 1 Bit | CW | |
| 80 | Output D | Forced Positioning | 2 Bit | CW | |
| 80 | Output D | Forced Positioning | 1 Bit | CW | |
| 81 | Output D | Threshold input | 2 Bytes | CW | |
| 81 | Output D | Threshold input | 1 Byte | CW | |
| 82 | Output D | Change Threshold value 1 | 1 Byte | CW | |
| 82 | Output D | Change Threshold value 1 | 2 Bytes | CW | |
| 83 | x | Dummy | 1 Bit | ||
| 84 | x | Dummy | 1 Bit | ||
| 85 | Output D | Contact monitoring | 1 Bit | CT | |
| 86 | Output D | Current Value | 2 Bytes | CRT | |
| 86 | Output D | Current Value | 4 Bytes | CRT | |
| 87 | Output D | Status Current-Threshold 1 | 1 Bit | CT | |
| 88 | Output D | Status Current-Threshold 2 | 1 Bit | CT | |
| 89 | Output D | Status Switch | 1 Bit | CRT |
Parameters (123)
| Parameter | Type | Default |
|---|---|---|
| Transmission and switching delay after recovery of bus voltage (2...255s) | unsignedInt 2…255 | 2 |
| Rate of telegrams | list | not limited |
| Rate of telegrams | unsignedInt 0…255 | 59 |
| Send cyclical "In operation" telegram (0...65.535s, 0 = inactive) | unsignedInt 0…65535 | 0 |
| Enable Safety Object for operating mode "Switch Actuator" | list | no |
| Remark: Reaction of output on "Function Safety Priority x" | list | is set on parameter-window "X: Safety" |
| Function Safety Priority 1 | list | inactive |
| Control period in seconds (0...65.535, 0 = inactive) | unsignedInt 0…65535 | 0 |
| Function Safety Priority 2 | list | inactive |
| Function Safety Priority 3 | list | inactive |
| Operating mode of output A | list | Switch Actuator |
| Status response of switching state Object "Status Switch" | list | only after changing |
| Object value switching status (Object "Status Switch") | list | 1=closed, 0=open |
| Reaction on bus voltage failure | list | Contact unchanged |
| Connected valve type | list | normally closed |
| Control telegram is received as | list | 1 bit (PWM or on-off control) |
| Transmit status response Object "Status heating" | list | no |
| Value object "Switch" on bus voltage recovery | list | not write |
| Overwrite scene, preset and threshold value 1 with download | list | yes |
| PWM-cycle time for continuous control Minutes (3...65.535) | unsignedInt 3…65535 | 10 |
| PWM-cycle time for continuous control Seconds (0...59) | unsignedInt 0…59 | 0 |
| Position of the valve drive on bus voltage recovery | list | 0% (closed) |
| Enable monitoring of the controller | list | no |
| Enable function "forced operation" | list | no |
| Reaction of output A | list | Normally open contact |
| Enable function "valve purge" | list | no |
| Enable time functions "delay, staircase lighting, flashing" | list | no |
| Value object "Disable Time Function" after bus voltage recovery | list | "0", enable time functions |
| Enable function "presets" | list | no |
| Enable function "scene (8 bit)" | list | no |
| Enable function "logic" | list | no |
| Enable functions "priority and safety operation" | list | no |
| Enable function "threshold" | list | no |
| Enable function "current detection" | list | no |
| Send status via object "contact monitoring" | list | no |
| Rückmeldung Sromüberwachung invertieren | list | no |
| State without function | list | not write |
| Time function | list | Staircase lighting function |
| in seconds (0...59) | unsignedInt 0…59 | 0 |
| Flashing if object "Switching" is | list | always flashing, ON (1) or OFF (0) |
| in minutes (0...65.535) | unsignedInt 0…65535 | 60 |
| Duration of staircase lighting Minutes (0...1000) | unsignedInt 0…1000 | 5 |
| Delay for switching on: (Min.(0...65535) | unsignedInt 0…65535 | 0 |
| Time for ON: Min. (0...65.535) | unsignedInt 0…65535 | 0 |
| Seconds (0...59) | unsignedInt 0…59 | 0 |
| Delay for switching on: Sec. (0...59) | unsignedInt 0…59 | 0 |
| Time for ON: Sec. (1...59) | unsignedInt 1…59 | 5 |
| Position of the valve drive during fault of room thermostat | list | unchanged |
| Time for OFF: Min. (0...65.535) | unsignedInt 0…65535 | 0 |
| Delay for switching OFF: Min. (0...65.53 | unsignedInt 0…65535 | 0 |
| Delay for switching OFF: Sec. (0...59) | unsignedInt 0…59 | 0 |
| Time for OFF: Sec. (1...59) | unsignedInt 1…59 | 5 |
| Enable object "RTR fault" | list | no |
| Number of ON-impulses: (1...100) | unsignedInt 1…100 | 5 |
| Extending staircase lighting by multiple operation ("pumping up") | list | yes (retriggerable) |
| Contact position after flashing | list | calculate present contact position |
| Staircase lighting can be switched off | list | ON with "1" and OFF with "0" |
| Warning before end of staircase lighting | list | via object |
| Warning time in sec. (0...65.535) add to duration of staircase lighting | unsignedInt 0…65535 | 45 |
| Valve position during forced positioning | list | unchanged |
| Duration of staircase lighting can be changed by object | list | no |
| Restart of staircase time after end of permanent ON | list | no |
| Note: Observe contact life and switching frequency per minute | list | see technical data |
| Time of valve purge in minutes (0...255) | unsignedInt 0…255 | 10 |
| Automatic valve purge | list | disable |
| Automatic valve purge | unsignedInt 0…65000 | 0 |
| Reaction on preset 1 (telegr. value 0) | list | no reaction |
| Reaction on preset 2 (telegr. value 1) | list | no reaction |
| Preset can be set via the bus | list | yes |
| Output is assigned to (Scene 1...64) | list | no allocation |
| Standard value | list | ON |
| Logical Connection 1 | list | disable |
| Function of object "Logical connection2" | list | AND |
| Gate disabled, if Object value "Logical connection 1" is | list | "0" |
| Result is inverted | list | no |
| Object value "Logical connection 1" after bus voltage recovery | list | "0" |
| Logical Connection 2 | list | disable |
| Gate disabled, if Object value "Logical connection 2" is | list | "0" |
| Object value "Logical connection 2" after bus voltage recovery | list | "0" |
| Enable "Safety Priority x" | list | on parameter-window "General" |
| Contact position if Safety Priority 1 | list | inactive |
| Contact position if forced operation | list | inactive |
| Object value "Forced positioning" on bus voltage recovery | list | disable |
| Object value "Forced positioning" on bus voltage recovery | list | "0" inactive |
| Contact position if Safety Priority 2 | list | inactive |
| Contact position if Safety Priority 3 | list | inactive |
| Reaction when forced operation and all Safety Priority x end | list | calculate present contact position |
| Data type of object "Threshold input" | list | 1 byte (0...255) |
| Change Threshold 1 over bus | list | no |
| Threshold value 1 (0...65.535)) | unsignedInt 0…65535 | 20000 |
| Threshold value 1 (0...255) | unsignedInt 0…255 | 80 |
| Threshold value 2 (0...255) | unsignedInt 0…255 | 160 |
| Threshold value 2 (0...65.535) | unsignedInt 0…65535 | 40000 |
| Threshold values define hysteresis | list | yes |
| Falling below lower threshold | list | no reaction |
| Object value < lower threshold | list | no reaction |
| Lower thrsh. <= object <= upper thrsh. | list | no reaction |
| Object value > lower threshold | list | no reaction |
| Exceeding upper threshold | list | no reaction |
| Object "threshold input" value on bus voltage recovery (0...255) | unsignedInt 0…255 | 0 |
| Object "threshold input" value on bus voltage recovery (0...65.535) | unsignedInt 0…65535 | 0 |
| Datapoint type object "Current Value" (0...65,535 in mA) | list | 2 byte counter (DPT 7.012) |
| Send current value, transmission time (0...65.535s, 0 = not send) | unsignedInt 0…65535 | 0 |
| Send current value on change of value | list | no |
| Enable current threshold value(s) | list | no |
| Evaluation | list | only with closed contact |
| Evaluation delay (0...255s) after contact closing | unsignedInt 0…255 | 3 |
| Scaling Current-Threshold in | list | 100mA |
| Current threshold 1 in mA (scaled in 10mA or 100mA) | unsignedInt 1…250 | 3 |
| Value of hysteresis current threshold 1 | list | 50mA |
| Current threshold 1 +/- hysteresis | list | send "1" at crossing over |
| Enable current threshold 2 | list | no |
| Current threshold 2 in mA (scaled in 10mA or 100mA) | unsignedInt 1…250 | 40 |
| Value of hysteresis current threshold 2 | list | 50mA |
| Current threshold 2 +/- hysteresis | list | send "1" at crossing over |
| Only for sinusoidal current the current value is the rms value | list | see technical data |
| Operating mode of output B | list | Switch Actuator |
| Reaction of output B | list | Normally open contact |
| Only for sinusoidal current the current value is the rms value | list | see technical data |
| Operating mode of output C | list | Switch Actuator |
| Reaction of output C | list | Normally open contact |
| Operating mode of output D | list | Switch Actuator |
| Reaction of output D | list | Normally open contact |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Switch 2f 16CS/3.2 3.2 latest | $A05B | 2C5D | 2026-11-25 | 475 KB | Download |
About this file
This is the official ETS product database for the ABB AG - BUSCH-JAEGER 6194/11-101 Binärausgang,2f,16/20A,Stromerk.,REG (6194/11-101), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from ABB AG - BUSCH-JAEGER
- 6151/11 Switching act. 1gang w/ bin. Inputs 6151/11 U
- 6194/12-101 Binärausgang,4f, 16/20A,Stromerk.,REG 6194/12-101
- 6194/13-101 Binärausgang,8f,16/20A,Stromerk.,REG 6194/13-101
- 6194/14-101 Binärausgang,12f,16/20A,C-Last,REG 6194/14-101
- 6194/18 Binärausgang 12f,16/20A,Stromerk.,REG 6194/18
- 6194/20 Binärausgang,2f,16/20A,C-Last,REG 6194/20
- 6194/21 Binärausgang,4f,16/20A,C-Last,REG 6194/21
- 6194/22 Binärausgang,4f,16/20A,C-Last,REG 6194/22
- SA/S2.16.2.1 Switch Actuator,2-fold,16A,MDRC 6194/25
- SA/S4.16.2.1 Switch Actuator,4-fold,16A,MDRC 6194/26
- SA/S8.16.2.1 Switch Actuator,8-fold,16A,MDRC 6194/27
- SA/S12.16.2.1 Switch Actuator,12-fold,16A,MDRC 6194/28