KNX Database
Theben AG 4930240 HMG 6 T

HMG 6 T 4930240

Theben AG · Order number 4930240 · Heizungsaktoren › HMG 6 T

6 x MIX2 heating actuator

Download .knxprod MIX 2 V1.C (1.12) 1.12 · 3.5 MB

Product

ManufacturerTheben AG
Product nameHMG 6 T
Order number4930240
Product textHMG 6 T (6 x heating actuator)
HardwareMIX 2 Series HMG 6 T
MediumTwisted Pair
Bus current (mA)5
Rail mountedYes
Width (mm)72
RegistrationCertified · 2018-04-20
Languagesde-DE, en-US, es-ES, fr-FR, it-IT, nl-NL, pl-PL
Catalog entryM-0048_H-4930240-1_HP-493A-1C-E04E_CI-4930240-1
FingerprintE04E
SHA-256ca8ba371c01f1185797f1d1f1db1cd9e8e2abb97917bf89891abbf55d77290e8
First seen2026-11-25
Markets59 markets

Application program: MIX 2 V1.C (1.12) 1.12

Application number$493A
Version1.12
Mask versionMV-0701 (7.1)
KNX Data SecureNo
Minimum ETS version4.0
Parameters23627
Group objects4230
Group objects (4230)
NoNameFunctionSizeDPTFlags
0RMG 4 I channel C1Threshold value in %1 ByteCRW
0RMG 4 I channel C1Threshold value 0..2551 ByteCRW
0RMG 4 I channel C1Thresh. value EIS 5 (DPT9.xxx)2 BytesCRW
0RMG 4 I channel C1Threshold value 0..655352 BytesCRW
0RMG 4 I channel C1Switching object1 BitCRW
0RMG 8 S channel C1Threshold value in %1 ByteCRW
0RMG 8 S channel C1Threshold value 0..2551 ByteCRW
0RMG 8 S channel C1Thresh. value EIS 5 (DPT9.xxx)2 BytesCRW
0RMG 8 S channel C1Threshold value 0..655352 BytesCRW
0RMG 8 S channel C1Switching object1 BitCRW
0DMG 2 T channel C1Switching ON/OFF1 BitCRWU
0JMG 4 T channel C1UP / DOWN1 BitCRWU
0RMG 4 U Channel C1Switching object1 BitCRW
0RMG 4 U Channel C1Threshold value in %1 ByteCRW
0RMG 4 U Channel C1Threshold value 0..2551 ByteCRW
0RMG 4 U Channel C1Thresh. value EIS 5 (DPT9.xxx)2 BytesCRW
0RMG 4 U Channel C1Threshold value 0..655352 BytesCRW
0HMG 6 T Channel H1Continuous actuating value1 ByteCRWU
0HMG 6 T Channel H1Switching actuating value1 BitCRWU
0HMG 6 T Channel H1Base setpoint value2 BytesCRW
0RMG 8 T Channel C1UP / DOWN1 BitCRWU
0RMG 8 T Channel C1Threshold value in %1 ByteCRW
0RMG 8 T Channel C1Threshold value 0..2551 ByteCRW
0RMG 8 T Channel C1Thresh. value EIS 5 (DPT9.xxx)2 BytesCRW
0RMG 8 T Channel C1Threshold value 0..655352 BytesCRW
0RMG 8 T Channel C1Switching object1 BitCRW
0BMG 6 T Channel I1Comparison value reached1 BitCRTU
0BMG 6 T Channel I1Transmit counter value2 BytesCRTU
0BMG 6 T Channel I1Switching ON/OFF1 BitCRWTU
0BMG 6 T Channel I1Step / stop1 BitCRTU
0BMG 6 T Channel I1.1Priority2 BitCRTU
0BMG 6 T Channel I1.1Switching ON/OFF1 BitCRWTU
0BMG 6 T Channel I1.1Transmit percentage1 ByteCRTU
0BMG 6 T Channel I1.14 byte DPT 14.x4 BytesCRTU
0BMG 6 T Channel I1.12 byte DPT 9.x2 BytesCRTU
0BMG 6 T Channel I1.1Transmit value1 ByteCRTU
0BMG 6 T Channel I1.1Switching ON/OFF1 BitCRTU
0BMG 6 T Channel I1.12 byte DPT 9.x2 BytesCRWTU
0BMG 6 T Channel I1.14 byte DPT 14.x4 BytesCRWTU
0BMG 6 T Channel I1.1Priority2 BitCRWTU
0BMG 6 T Channel I1.1Repeat 1 Byte1 ByteCRWTU
1RMG 4 I channel C1Logic input in XOR gate1 BitCRW
1RMG 4 I channel C1Logic input in OR gate1 BitCRW
1RMG 4 I channel C1Logic input in AND gate1 BitCRW
1RMG 8 S channel C1Logic input in XOR gate1 BitCRW
1RMG 8 S channel C1Logic input in OR gate1 BitCRW
1RMG 8 S channel C1Logic input in AND gate1 BitCRW
1DMG 2 T channel C1Brighter/darker4 BitCRWU
1JMG 4 T channel C1Step / stop1 BitCRWU
1RMG 4 U Channel C1Logic input in XOR gate1 BitCRW
1RMG 4 U Channel C1Logic input in OR gate1 BitCRW
1RMG 4 U Channel C1Logic input in AND gate1 BitCRW
1HMG 6 T Channel H1Manual set point offset2 BytesCRW
1RMG 8 T Channel C1Step / stop1 BitCRWU
1RMG 8 T Channel C1Logic input in XOR gate1 BitCRW
1RMG 8 T Channel C1Logic input in OR gate1 BitCRW
1RMG 8 T Channel C1Logic input in AND gate1 BitCRW
1BMG 6 T Channel I1UP1 BitCRTU
1BMG 6 T Channel I1UP / DOWN1 BitCRWTU
1BMG 6 T Channel I1DOWN1 BitCRTU
1BMG 6 T Channel I1Brighter/darker4 BitCRTU
1BMG 6 T Channel I1Darker4 BitCRWTU
1BMG 6 T Channel I1Darker4 BitCRTU
1BMG 6 T Channel I1Brighter4 BitCRWTU
1BMG 6 T Channel I1Brighter4 BitCRTU
1BMG 6 T Channel I1.2Priority2 BitCRTU
1BMG 6 T Channel I1.2Switching ON/OFF1 BitCRWTU
1BMG 6 T Channel I1.2Transmit percentage1 ByteCRTU
1BMG 6 T Channel I1.24 byte DPT 14.x4 BytesCRTU
1BMG 6 T Channel I1.22 byte DPT 9.x2 BytesCRTU
1BMG 6 T Channel I1.2Transmit value1 ByteCRTU
1BMG 6 T Channel I1.2Switching ON/OFF1 BitCRTU
1BMG 6 T Channel I1Current counter value2 BytesCRTU
2RMG 8 S channel C1Lock1 BitCRW
2RMG 4 I channel C1Lock1 BitCRW
2DMG 2 T channel C1Dimming value1 ByteCWU
2JMG 4 T channel C1% Height1 ByteCRWU
2RMG 4 U Channel C1Lock1 BitCRW
2HMG 6 T Channel H1Block valve protection1 BitCRW
2HMG 6 T Channel H1Actual value2 BytesCRWU
2RMG 8 T Channel C1% Height1 ByteCRWU
2RMG 8 T Channel C1Lock1 BitCRW
2BMG 6 T Channel I1.34 byte DPT 14.x4 BytesCRTU
2BMG 6 T Channel I1.32 byte DPT 9.x2 BytesCRTU
2BMG 6 T Channel I1.3Priority2 BitCRTU
2BMG 6 T Channel I1.3Switching ON/OFF1 BitCRWTU
2BMG 6 T Channel I1.3Transmit percentage1 ByteCRTU
2BMG 6 T Channel I1.3Transmit value1 ByteCRTU
2BMG 6 T Channel I1.1Switching ON/OFF1 BitCRWTU
2BMG 6 T Channel I1.1Transmit percentage1 ByteCRTU
2BMG 6 T Channel I1.1Transmit value1 ByteCRTU
2BMG 6 T Channel I1.1Height %1 ByteCRTU
2BMG 6 T Channel I1.3Switching ON/OFF1 BitCRTU
3RMG 8 S channel C1Call up/save scenes1 ByteCRWTU
3RMG 4 I channel C1Call up/save scenes1 ByteCRWTU
3DMG 2 T channel C1Soft switching1 BitCRWU
3JMG 4 T channel C1% Lamella1 ByteCRWU
3RMG 4 U Channel C1Call up/save scenes1 ByteCRWTU
3HMG 6 T Channel H1Current actuating value1 ByteCRTU
3HMG 6 T Channel H1Operating mode preset1 ByteCRW
3RMG 8 T Channel C1% Lamella1 ByteCRWU
3RMG 8 T Channel C1Call up/save scenes1 ByteCRWTU
3BMG 6 T Channel I1.4Transmit value1 ByteCRTU
3BMG 6 T Channel I1.4Priority2 BitCRTU
3BMG 6 T Channel I1.4Switching ON/OFF1 BitCRTU
3BMG 6 T Channel I1.4Transmit percentage1 ByteCRTU
3BMG 6 T Channel I1.2Lamella %1 ByteCRTU
4RMG 8 S channel C1Lock scenes = 11 BitCRW
4RMG 8 S channel C1Enable scenes = 11 BitCRW
4RMG 4 I channel C1Enable scenes = 11 BitCRW
4RMG 4 I channel C1Lock scenes = 11 BitCRW
4DMG 2 T channel C1Lock1 BitCRWU
4JMG 4 T channel C1Lock comfort/automatic1 BitCRWU
4RMG 4 U Channel C1Lock scenes = 11 BitCRW
4RMG 4 U Channel C1Enable scenes = 11 BitCRW
4HMG 6 T Channel H1Presence1 BitCRW
4RMG 8 T Channel C1Lock comfort/automatic1 BitCRWU
4RMG 8 T Channel C1Lock scenes = 11 BitCRW
4RMG 8 T Channel C1Enable scenes = 11 BitCRW
4BMG 6 T Channel I11 = enable counter1 BitCRWU
4BMG 6 T Channel I11 = lock counter1 BitCRWU
4BMG 6 T Channel I1Disable = 11 BitCRWU
4BMG 6 T Channel I1Disable = 01 BitCRWU
5RMG 4 I channel C1Feedback ON/OFF1 BitCRTU
5RMG 8 S channel C1Feedback ON/OFF1 BitCRTU
5DMG 2 T channel C1Call up/save scenes1 ByteCRWU
5JMG 4 T channel C11 = Lock1 BitCRWU
5JMG 4 T channel C11 = Release1 BitCRWU
5RMG 4 U Channel C1Feedback ON/OFF1 BitCRTU
5HMG 6 T Channel H1Window position1 BitCRW
5RMG 8 T Channel C11 = Lock1 BitCRWU
5RMG 8 T Channel C11 = Release1 BitCRWU
5RMG 8 T Channel C1Feedback ON/OFF1 BitCRTU
5BMG 6 T Channel I1Counter reset1 BitCRWU
5BMG 6 T Channel I1Confirm alert1 BitCRWU
6RMG 8 S channel C1Time to next service2 BytesCRWTU
6RMG 8 S channel C1Operating hours feedback2 BytesCRWT
6RMG 4 I channel C1Operating hours feedback2 BytesCRWT
6RMG 4 I channel C1Time to next service2 BytesCRWTU
6DMG 2 T channel C1Lock scenes = 11 BitCRW
6DMG 2 T channel C1Enable scenes = 11 BitCRW
6JMG 4 T channel C1Call up/save scenes1 ByteCRWU
6RMG 4 U Channel C1Time to next service2 BytesCRWTU
6RMG 4 U Channel C1Operating hours feedback2 BytesCRWT
6HMG 6 T Channel H1Current operating mode1 ByteCRT
6RMG 8 T Channel C1Call up/save scenes1 ByteCRWU
6RMG 8 T Channel C1Operating hours feedback2 BytesCRWT
6RMG 8 T Channel C1Time to next service2 BytesCRWTU
7RMG 8 S channel C1Service required1 BitCRTU
7RMG 4 I channel C1Service required1 BitCRTU
7DMG 2 T channel C1Force = 11 BitCRWU
7DMG 2 T channel C1Force = 01 BitCRWU
7DMG 2 T channel C1Dimming value with forced op1 ByteCRWU
7DMG 2 T channel C1 Forced mode2 BitCRWU
7JMG 4 T channel C1Enable scenes = 11 BitCRW
7JMG 4 T channel C1Lock scenes = 11 BitCRW
7RMG 4 U Channel C1Service required1 BitCRTU
7HMG 6 T Channel H1Heating actuating value1 ByteCRT
7HMG 6 T Channel H1Heat & cool actuating values1 ByteCRT
7RMG 8 T Channel C1Enable scenes = 11 BitCRW
7RMG 8 T Channel C1Lock scenes = 11 BitCRW
7RMG 8 T Channel C1Service required1 BitCRTU
8RMG 8 S channel C1Switching with priority2 BitCRW
8RMG 8 S channel C1Reset service1 BitCRW
8RMG 8 S channel C1Reset operating hours1 BitCRW
8RMG 4 I channel C1Reset operating hours1 BitCRW
8RMG 4 I channel C1Reset service1 BitCRW
8RMG 4 I channel C1Switching with priority2 BitCRW
8DMG 2 T channel C1Dimming value limit1 ByteCRWU
8JMG 4 T channel C1Priority on safety2 BitCRWU
8RMG 4 U Channel C1Switching with priority2 BitCRW
8RMG 4 U Channel C1Reset service1 BitCRW
8RMG 4 U Channel C1Reset operating hours1 BitCRW
8HMG 6 T Channel H1Cooling actuating value1 ByteCRT
8RMG 8 T Channel C1Priority on safety2 BitCRWU
8RMG 8 T Channel C1Reset operating hours1 BitCRW
8RMG 8 T Channel C1Reset service1 BitCRW
8RMG 8 T Channel C1Switching with priority2 BitCRW
9RMG 4 I channel C1Theoretical power2 BytesCRTU
9RMG 4 I channel C1Current value2 BytesCRTU
9DMG 2 T channel C1Feedback On/Off1 BitCRTU
9JMG 4 T channel C1Presence1 BitCRW
9JMG 4 T channel C1Position A1 BitCRWU
9HMG 6 T Channel H1Heating = 1, Cooling = 01 BitDPT.1CRW
9HMG 6 T Channel H1Heating = 0, Cooling = 11 Bit1.1 switchCRW
9HMG 6 T Channel H1Forced operation mode1 BitCRWU
10RMG 8 S channel C2Threshold value in %1 ByteCRW
10RMG 8 S channel C2Threshold value 0..655352 BytesCRW
10RMG 8 S channel C2Threshold value 0..2551 ByteCRW
10RMG 8 S channel C2Thresh. value EIS 5 (DPT9.xxx)2 BytesCRW
10RMG 8 S channel C2Switching object1 BitCRW
10RMG 4 I channel C1Overload1 BitCRT
10DMG 2 T channel C1Feedback in %1 ByteCRTU
10JMG 4 T channel C1Heating support1 BitCRWU
10JMG 4 T channel C1Position B1 BitCRWU
10RMG 4 U Channel C2Switching object1 BitCRW
10RMG 4 U Channel C2Threshold value in %1 ByteCRW
10RMG 4 U Channel C2Threshold value 0..655352 BytesCRW
10RMG 4 U Channel C2Threshold value 0..2551 ByteCRW
10RMG 4 U Channel C2Thresh. value EIS 5 (DPT9.xxx)2 BytesCRW
10HMG 6 T Channel H1Current setpoint value2 BytesCRWT
10RMG 8 T Channel C2UP / DOWN1 BitCRWU
10RMG 8 T Channel C2Threshold value in %1 ByteCRW
10RMG 8 T Channel C2Threshold value 0..655352 BytesCRW
10RMG 8 T Channel C2Threshold value 0..2551 ByteCRW
10RMG 8 T Channel C2Thresh. value EIS 5 (DPT9.xxx)2 BytesCRW
10RMG 8 T Channel C2Switching object1 BitCRW
10BMG 6 T Channel I2Switching ON/OFF1 BitCRWTU
10BMG 6 T Channel I2.1Priority2 BitCRTU
10BMG 6 T Channel I2.1Switching ON/OFF1 BitCRWTU
10BMG 6 T Channel I2.1Transmit percentage1 ByteCRTU
10BMG 6 T Channel I2.12 byte DPT 9.x2 BytesCRTU
10BMG 6 T Channel I2.14 byte DPT 14.x4 BytesCRTU
10BMG 6 T Channel I2.1Transmit value1 ByteCRTU
10BMG 6 T Channel I2Transmit counter value2 BytesCRTU
10BMG 6 T Channel I2Comparison value reached1 BitCRTU
10BMG 6 T Channel I2.1Switching ON/OFF1 BitCRTU
10BMG 6 T Channel I2.1Priority2 BitCRWTU
10BMG 6 T Channel I2.14 byte DPT 14.x4 BytesCRWTU
10BMG 6 T Channel I2.12 byte DPT 9.x2 BytesCRWTU
10BMG 6 T Channel I2.1Repeat 1 Byte1 ByteCRWTU
10BMG 6 T Channel I2Step / stop1 BitCRTU
11RMG 4 I channel C1Underload1 BitCRT
11RMG 8 S channel C2Logic input in XOR gate1 BitCRW
11RMG 8 S channel C2Logic input in OR gate1 BitCRW
11RMG 8 S channel C2Logic input in AND gate1 BitCRW
11DMG 2 T channel C1Time to next service2 BytesCRWTU
11DMG 2 T channel C1Operating hours feedback2 BytesCRWT
11JMG 4 T channel C1Cooling support1 BitCRWU
11JMG 4 T channel C1Position C1 BitCRWU
11RMG 4 U Channel C2Logic input in XOR gate1 BitCRW
11RMG 4 U Channel C2Logic input in OR gate1 BitCRW
11RMG 4 U Channel C2Logic input in AND gate1 BitCRW
11HMG 6 T Channel H1Report actuating value failure1 BitCRTU
11HMG 6 T Channel H1Report actual value failure1 BitCRTU
11RMG 8 T Channel C2Step / stop1 BitCRWU
11RMG 8 T Channel C2Logic input in XOR gate1 BitCRW
11RMG 8 T Channel C2Logic input in OR gate1 BitCRW
11RMG 8 T Channel C2Logic input in AND gate1 BitCRW
11BMG 6 T Channel I2Darker4 BitCRTU
11BMG 6 T Channel I2Brighter4 BitCRTU
11BMG 6 T Channel I2Darker4 BitCRWTU
11BMG 6 T Channel I2Brighter4 BitCRWTU
11BMG 6 T Channel I2Brighter/darker4 BitCRTU
11BMG 6 T Channel I2.2Transmit value1 ByteCRTU
11BMG 6 T Channel I2.2Priority2 BitCRTU
11BMG 6 T Channel I2.2Switching ON/OFF1 BitCRWTU
11BMG 6 T Channel I2.2Transmit percentage1 ByteCRTU
11BMG 6 T Channel I2.24 byte DPT 14.x4 BytesCRTU
11BMG 6 T Channel I2.22 byte DPT 9.x2 BytesCRTU
11BMG 6 T Channel I2.2Switching ON/OFF1 BitCRTU
11BMG 6 T Channel I2DOWN1 BitCRTU
11BMG 6 T Channel I2UP / DOWN1 BitCRWTU
11BMG 6 T Channel I2UP1 BitCRTU
11BMG 6 T Channel I2Current counter value2 BytesCRTU
12RMG 4 I channel C1Contact error1 BitCRTU
12RMG 8 S channel C2Lock1 BitCRW
12DMG 2 T channel C1Service required1 BitCRTU
12JMG 4 T channel C1Room temperature2 BytesCRWU
12RMG 4 U Channel C2Lock1 BitCRW
12HMG 6 T Channel H2Continuous actuating value1 ByteCRWU
12HMG 6 T Channel H2Switching actuating value1 BitCRWU
12HMG 6 T Channel H2Base setpoint value2 BytesCRW
12RMG 8 T Channel C2% Height1 ByteCRWU
12RMG 8 T Channel C2Lock1 BitCRW
12BMG 6 T Channel I2.1Transmit percentage1 ByteCRTU
12BMG 6 T Channel I2.1Transmit value1 ByteCRTU
12BMG 6 T Channel I2.1Switching ON/OFF1 BitCRWTU
12BMG 6 T Channel I2.34 byte DPT 14.x4 BytesCRTU
12BMG 6 T Channel I2.32 byte DPT 9.x2 BytesCRTU
12BMG 6 T Channel I2.3Priority2 BitCRTU
12BMG 6 T Channel I2.3Switching ON/OFF1 BitCRWTU
12BMG 6 T Channel I2.3Transmit percentage1 ByteCRTU
12BMG 6 T Channel I2.3Transmit value1 ByteCRTU
12BMG 6 T Channel I2.3Switching ON/OFF1 BitCRTU
12BMG 6 T Channel I2.1Height %1 ByteCRTU
13JMG 4 T Channel C1Height feedback 1 bit1 BitCRTU
13RMG 4 I channel C1Logic input in OR gate1 BitCRW
13RMG 8 S channel C2Call up/save scenes1 ByteCRWTU
13DMG 2 T channel C1Reset service1 BitCRW
13DMG 2 T channel C1Reset operating hours1 BitCRW
13JMG 4 T channel C1Height feedback %1 ByteCRTU
13RMG 4 U Channel C2Call up/save scenes1 ByteCRWTU
13HMG 6 T Channel H2Manual set point offset2 BytesCRW
13RMG 8 T Channel C2% Lamella1 ByteCRWU
13RMG 8 T Channel C2Call up/save scenes1 ByteCRWTU
13BMG 6 T Channel I2.4Transmit value1 ByteCRTU
13BMG 6 T Channel I2.4Priority2 BitCRTU
13BMG 6 T Channel I2.4Transmit percentage1 ByteCRTU
13BMG 6 T Channel I2.4Switching ON/OFF1 BitCRTU
13BMG 6 T Channel I2.2Lamella %1 ByteCRTU
14RMG 4 I channel C1Logic input in OR gate1 BitCRW
14RMG 8 S channel C2Enable scenes = 11 BitCRW
14RMG 8 S channel C2Lock scenes = 11 BitCRW
14DMG 2 T channel C1General error message1 BitCRTU
14JMG 4 T channel C1Lamella feedback %1 ByteCRTU
14RMG 4 U Channel C2Enable scenes = 11 BitCRW
14RMG 4 U Channel C2Lock scenes = 11 BitCRW
14HMG 6 T Channel H2Block valve protection1 BitCRW
14HMG 6 T Channel H2Actual value2 BytesCRWU
14RMG 8 T Channel C2Lock comfort/automatic1 BitCRWU
14RMG 8 T Channel C2Enable scenes = 11 BitCRW
14RMG 8 T Channel C2Lock scenes = 11 BitCRW
14BMG 6 T Channel I2Disable = 01 BitCRWU
14BMG 6 T Channel I2Disable = 11 BitCRWU
14BMG 6 T Channel I21 = lock counter1 BitCRWU
14BMG 6 T Channel I21 = enable counter1 BitCRWU
15RMG 8 S channel C2Feedback ON/OFF1 BitCRTU
15DMG 2 T channel C1Short circuit message1 BitCRTU
15Reserve object 15Reserve2 BytesCRWU
15RMG 4 U Channel C2Feedback ON/OFF1 BitCRTU
15HMG 6 T Channel H2Current actuating value1 ByteCRTU
15HMG 6 T Channel H2Operating mode preset1 ByteCRW
15RMG 8 T Channel C21 = Lock1 BitCRWU
15RMG 8 T Channel C21 = Release1 BitCRWU
15RMG 8 T Channel C2Feedback ON/OFF1 BitCRTU
15BMG 6 T Channel I2Counter reset1 BitCRWU
15BMG 6 T Channel I2Confirm alert1 BitCRWU
16RMG 8 S channel C2Operating hours feedback2 BytesCRWT
16RMG 8 S channel C2Time to next service2 BytesCRWTU
16DMG 2 T channel C1Excess temperature message1 BitCRTU
16JMG 4 T channel C1Start-up mode1 BitCRWU
16RMG 4 U Channel C2Time to next service2 BytesCRWTU
16RMG 4 U Channel C2Operating hours feedback2 BytesCRWT
16HMG 6 T Channel H2Presence1 BitCRW
16RMG 8 T Channel C2Call up/save scenes1 ByteCRWU
16RMG 8 T Channel C2Operating hours feedback2 BytesCRWT
16RMG 8 T Channel C2Time to next service2 BytesCRWTU
17RMG 8 S channel C2Service required1 BitCRTU
17DMG 2 T channel C1Mains power failure1 BitCRTU
17JMG 4 T channel C1Receive runtime2 BytesCRW
17JMG 4 T channel C1Send runtime2 BytesCRT
17RMG 4 U Channel C2Service required1 BitCRTU
17HMG 6 T Channel H2Window position1 BitCRW
17RMG 8 T Channel C2Enable scenes = 11 BitCRW
17RMG 8 T Channel C2Lock scenes = 11 BitCRW
17RMG 8 T Channel C2Service required1 BitCRTU
18RMG 8 S channel C2Reset operating hours1 BitCRW
18RMG 8 S channel C2Reset service1 BitCRW
18RMG 8 S channel C2Switching with priority2 BitCRW
18DMG 2 T channel C1Load type message (R, C/L)1 BitCRTU
18RMG 4 U Channel C2Switching with priority2 BitCRW
18RMG 4 U Channel C2Reset service1 BitCRW
18RMG 4 U Channel C2Reset operating hours1 BitCRW
18HMG 6 T Channel H2Current operating mode1 ByteCRT
18RMG 8 T Channel C2Priority on safety2 BitCRWU
18RMG 8 T Channel C2Reset operating hours1 BitCRW
18RMG 8 T Channel C2Reset service1 BitCRW
18RMG 8 T Channel C2Switching with priority2 BitCRW
19HMG 6 T Channel H2Heat & cool actuating values1 ByteCRT
19HMG 6 T Channel H2Heating actuating value1 ByteCRT
20RMG 4 I channel C2Switching object1 BitCRW
20RMG 4 I channel C2Threshold value in %1 ByteCRW
20RMG 4 I channel C2Threshold value 0..2551 ByteCRW
20RMG 4 I channel C2Threshold value 0..655352 BytesCRW
20RMG 4 I channel C2Thresh. value EIS 5 (DPT9.xxx)2 BytesCRW
20RMG 8 S channel C3Threshold value 0..2551 ByteCRW
20RMG 8 S channel C3Thresh. value EIS 5 (DPT9.xxx)2 BytesCRW
20RMG 8 S channel C3Threshold value 0..655352 BytesCRW
20RMG 8 S channel C3Threshold value in %1 ByteCRW
20RMG 8 S channel C3Switching object1 BitCRW
20JMG 4 T channel C2UP / DOWN1 BitCRWU
20RMG 4 U Channel C3Switching object1 BitCRW
20RMG 4 U Channel C3Threshold value 0..2551 ByteCRW
20RMG 4 U Channel C3Thresh. value EIS 5 (DPT9.xxx)2 BytesCRW
20RMG 4 U Channel C3Threshold value 0..655352 BytesCRW
20RMG 4 U Channel C3Threshold value in %1 ByteCRW
20HMG 6 T Channel H2Cooling actuating value1 ByteCRT
20RMG 8 T Channel C3Threshold value 0..2551 ByteCRW
20RMG 8 T Channel C3Thresh. value EIS 5 (DPT9.xxx)2 BytesCRW
20RMG 8 T Channel C3Threshold value 0..655352 BytesCRW
20RMG 8 T Channel C3Threshold value in %1 ByteCRW
20RMG 8 T Channel C3Switching object1 BitCRW
20RMG 8 T Channel C3UP / DOWN1 BitCRWU
20BMG 6 T Channel I3Switching ON/OFF1 BitCRWTU
20BMG 6 T Channel I3.1Priority2 BitCRTU
20BMG 6 T Channel I3.1Switching ON/OFF1 BitCRWTU
20BMG 6 T Channel I3.1Transmit percentage1 ByteCRTU
20BMG 6 T Channel I3.12 byte DPT 9.x2 BytesCRTU
20BMG 6 T Channel I3.14 byte DPT 14.x4 BytesCRTU
20BMG 6 T Channel I3.1Transmit value1 ByteCRTU
20BMG 6 T Channel I3Transmit counter value2 BytesCRTU
20BMG 6 T Channel I3Comparison value reached1 BitCRTU
20BMG 6 T Channel I3.1Switching ON/OFF1 BitCRTU
20BMG 6 T Channel I3.1Priority2 BitCRWTU
20BMG 6 T Channel I3.14 byte DPT 14.x4 BytesCRWTU
20BMG 6 T Channel I3.12 byte DPT 9.x2 BytesCRWTU
20BMG 6 T Channel I3.1Repeat 1 Byte1 ByteCRWTU
20BMG 6 T Channel I3Step / stop1 BitCRTU
21RMG 4 I channel C2Logic input in XOR gate1 BitCRW
21RMG 4 I channel C2Logic input in OR gate1 BitCRW
21RMG 4 I channel C2Logic input in AND gate1 BitCRW
21RMG 8 S channel C3Logic input in XOR gate1 BitCRW
21RMG 8 S channel C3Logic input in OR gate1 BitCRW
21RMG 8 S channel C3Logic input in AND gate1 BitCRW
21JMG 4 T channel C2Step / stop1 BitCRWU
21RMG 4 U Channel C3Logic input in XOR gate1 BitCRW
21RMG 4 U Channel C3Logic input in OR gate1 BitCRW
21RMG 4 U Channel C3Logic input in AND gate1 BitCRW
21HMG 6 T Channel H1Heating = 1, Cooling = 01 BitDPT.1CRW
21HMG 6 T Channel H2Heating = 0, Cooling = 11 Bit1.1 switchCRW
21HMG 6 T Channel H2Forced operation mode1 BitCRWU
21RMG 8 T Channel C3Logic input in OR gate1 BitCRW
21RMG 8 T Channel C3Logic input in AND gate1 BitCRW
21RMG 8 T Channel C3Logic input in XOR gate1 BitCRW
21RMG 8 T Channel C3Step / stop1 BitCRWU
21BMG 6 T Channel I3Darker4 BitCRWTU
21BMG 6 T Channel I3Brighter4 BitCRWTU
21BMG 6 T Channel I3Brighter/darker4 BitCRTU
21BMG 6 T Channel I3Darker4 BitCRTU
21BMG 6 T Channel I3Brighter4 BitCRTU
21BMG 6 T Channel I3.2Transmit value1 ByteCRTU
21BMG 6 T Channel I3.2Priority2 BitCRTU
21BMG 6 T Channel I3.2Switching ON/OFF1 BitCRWTU
21BMG 6 T Channel I3.2Transmit percentage1 ByteCRTU
21BMG 6 T Channel I3.24 byte DPT 14.x4 BytesCRTU
21BMG 6 T Channel I3.22 byte DPT 9.x2 BytesCRTU
21BMG 6 T Channel I3.2Switching ON/OFF1 BitCRTU
21BMG 6 T Channel I3UP1 BitCRTU
21BMG 6 T Channel I3DOWN1 BitCRTU
21BMG 6 T Channel I3UP / DOWN1 BitCRWTU
21BMG 6 T Channel I3Current counter value2 BytesCRTU
22RMG 4 I channel C2Lock1 BitCRW
22RMG 8 S channel C3Lock1 BitCRW
22JMG 4 T channel C2% Height1 ByteCRWU
22RMG 4 U Channel C3Lock1 BitCRW
22HMG 6 T Channel H2Current setpoint value2 BytesCRWT
22RMG 8 T Channel C3Lock1 BitCRW
22RMG 8 T Channel C3% Height1 ByteCRWU
22BMG 6 T Channel I3.1Transmit percentage1 ByteCRTU
22BMG 6 T Channel I3.1Transmit value1 ByteCRTU
22BMG 6 T Channel I3.1Switching ON/OFF1 BitCRWTU
22BMG 6 T Channel I3.34 byte DPT 14.x4 BytesCRTU
22BMG 6 T Channel I3.32 byte DPT 9.x2 BytesCRTU
22BMG 6 T Channel I3.3Priority2 BitCRTU
22BMG 6 T Channel I3.3Switching ON/OFF1 BitCRWTU
22BMG 6 T Channel I3.3Transmit percentage1 ByteCRTU
22BMG 6 T Channel I3.3Transmit value1 ByteCRTU
22BMG 6 T Channel I3.3Switching ON/OFF1 BitCRTU
22BMG 6 T Channel I3.1Height %1 ByteCRTU
23RMG 4 I channel C2Call up/save scenes1 ByteCRWTU
23RMG 8 S channel C3Call up/save scenes1 ByteCRWTU
23JMG 4 T channel C2% Lamella1 ByteCRWU
23RMG 4 U Channel C3Call up/save scenes1 ByteCRWTU
23HMG 6 T Channel H2Report actuating value failure1 BitCRTU
23HMG 6 T Channel H2Report actual value failure1 BitCRTU
23RMG 8 T Channel C3Call up/save scenes1 ByteCRWTU
23RMG 8 T Channel C3% Lamella1 ByteCRWU
23BMG 6 T Channel I3.4Transmit value1 ByteCRTU
23BMG 6 T Channel I3.4Priority2 BitCRTU
23BMG 6 T Channel I3.4Transmit percentage1 ByteCRTU
23BMG 6 T Channel I3.4Switching ON/OFF1 BitCRTU
23BMG 6 T Channel I3.2Lamella %1 ByteCRTU
24RMG 4 I channel C2Enable scenes = 11 BitCRW
24RMG 4 I channel C2Lock scenes = 11 BitCRW
24RMG 8 S channel C3Lock scenes = 11 BitCRW
24RMG 8 S channel C3Enable scenes = 11 BitCRW
24JMG 4 T channel C2Lock comfort/automatic1 BitCRWU
24RMG 4 U Channel C3Lock scenes = 11 BitCRW
24RMG 4 U Channel C3Enable scenes = 11 BitCRW
24HMG 6 T Channel H3Continuous actuating value1 ByteCRWU
24HMG 6 T Channel H3Switching actuating value1 BitCRWU
24HMG 6 T Channel H3Base setpoint value2 BytesCRW
24RMG 8 T Channel C3Lock scenes = 11 BitCRW
24RMG 8 T Channel C3Enable scenes = 11 BitCRW
24RMG 8 T Channel C3Lock comfort/automatic1 BitCRWU
24BMG 6 T Channel I3Disable = 01 BitCRWU
24BMG 6 T Channel I3Disable = 11 BitCRWU
24BMG 6 T Channel I31 = enable counter1 BitCRWU
24BMG 6 T Channel I31 = lock counter1 BitCRWU
25RMG 4 I channel C2Feedback ON/OFF1 BitCRTU
25RMG 8 S channel C3Feedback ON/OFF1 BitCRTU
25JMG 4 T channel C21 = Lock1 BitCRWU
25JMG 4 T channel C21 = Release1 BitCRWU
25RMG 4 U Channel C3Feedback ON/OFF1 BitCRTU
25HMG 6 T Channel H3Manual set point offset2 BytesCRW
25RMG 8 T Channel C3Feedback ON/OFF1 BitCRTU
25RMG 8 T Channel C31 = Lock1 BitCRWU
25RMG 8 T Channel C31 = Release1 BitCRWU
25BMG 6 T Channel I3Counter reset1 BitCRWU
25BMG 6 T Channel I3Confirm alert1 BitCRWU
26RMG 4 I channel C2Operating hours feedback2 BytesCRWT
26RMG 4 I channel C2Time to next service2 BytesCRWTU
26RMG 8 S channel C3Operating hours feedback2 BytesCRWT
26RMG 8 S channel C3Time to next service2 BytesCRWTU
26JMG 4 T channel C2Call up/save scenes1 ByteCRWU
26RMG 4 U Channel C3Time to next service2 BytesCRWTU
26RMG 4 U Channel C3Operating hours feedback2 BytesCRWT
26HMG 6 T Channel H3Block valve protection1 BitCRW
26HMG 6 T Channel H3Actual value2 BytesCRWU
26RMG 8 T Channel C3Operating hours feedback2 BytesCRWT
26RMG 8 T Channel C3Time to next service2 BytesCRWTU
26RMG 8 T Channel C3Call up/save scenes1 ByteCRWU
27RMG 4 I channel C2Service required1 BitCRTU
27RMG 8 S channel C3Service required1 BitCRTU
27JMG 4 T channel C2Enable scenes = 11 BitCRW
27JMG 4 T channel C2Lock scenes = 11 BitCRW
27RMG 4 U Channel C3Service required1 BitCRTU
27HMG 6 T Channel H3Current actuating value1 ByteCRTU
27HMG 6 T Channel H3Operating mode preset1 ByteCRW
27RMG 8 T Channel C3Service required1 BitCRTU
27RMG 8 T Channel C3Lock scenes = 11 BitCRW
27RMG 8 T Channel C3Enable scenes = 11 BitCRW
28RMG 4 I channel C2Reset operating hours1 BitCRW
28RMG 4 I channel C2Reset service1 BitCRW
28RMG 4 I channel C2Switching with priority2 BitCRW
28RMG 8 S channel C3Reset operating hours1 BitCRW
28RMG 8 S channel C3Reset service1 BitCRW
28RMG 8 S channel C3Switching with priority2 BitCRW
28JMG 4 T channel C2Priority on safety2 BitCRWU
28RMG 4 U Channel C3Switching with priority2 BitCRW
28RMG 4 U Channel C3Reset service1 BitCRW
28RMG 4 U Channel C3Reset operating hours1 BitCRW
28HMG 6 T Channel H3Presence1 BitCRW
28RMG 8 T Channel C3Reset operating hours1 BitCRW
28RMG 8 T Channel C3Reset service1 BitCRW
28RMG 8 T Channel C3Switching with priority2 BitCRW
28RMG 8 T Channel C3Priority on safety2 BitCRWU
29RMG 4 I channel C2Current value2 BytesCRTU
29RMG 4 I channel C2Theoretical power2 BytesCRTU
29JMG 4 T channel C2Presence1 BitCRW
29JMG 4 T channel C2Position A1 BitCRWU
29HMG 6 T Channel H3Window position1 BitCRW
30RMG 4 I channel C2Overload1 BitCRT
30RMG 8 S channel C4Threshold value 0..2551 ByteCRW
30RMG 8 S channel C4Thresh. value EIS 5 (DPT9.xxx)2 BytesCRW
30RMG 8 S channel C4Threshold value 0..655352 BytesCRW
30RMG 8 S channel C4Threshold value in %1 ByteCRW
30RMG 8 S channel C4Switching object1 BitCRW
30DMG 2 T channel C2Switching ON/OFF1 BitCRWU
30JMG 4 T channel C2Heating support1 BitCRWU
30JMG 4 T channel C2Position B1 BitCRWU
30RMG 4 U Channel C4Switching object1 BitCRW
30RMG 4 U Channel C4Threshold value 0..2551 ByteCRW
30RMG 4 U Channel C4Thresh. value EIS 5 (DPT9.xxx)2 BytesCRW
30RMG 4 U Channel C4Threshold value 0..655352 BytesCRW
30RMG 4 U Channel C4Threshold value in %1 ByteCRW
30HMG 6 T Channel H3Current operating mode1 ByteCRT
30RMG 8 T Channel C4Threshold value 0..2551 ByteCRW
30RMG 8 T Channel C4Thresh. value EIS 5 (DPT9.xxx)2 BytesCRW
30RMG 8 T Channel C4Threshold value 0..655352 BytesCRW
30RMG 8 T Channel C4Threshold value in %1 ByteCRW
30RMG 8 T Channel C4Switching object1 BitCRW
30RMG 8 T Channel C4UP / DOWN1 BitCRWU
30BMG 6 T Channel I4Switching ON/OFF1 BitCRWTU
30BMG 6 T Channel I4.1Priority2 BitCRTU
30BMG 6 T Channel I4.1Switching ON/OFF1 BitCRWTU
30BMG 6 T Channel I4.1Transmit percentage1 ByteCRTU
30BMG 6 T Channel I4.12 byte DPT 9.x2 BytesCRTU
30BMG 6 T Channel I4.14 byte DPT 14.x4 BytesCRTU
30BMG 6 T Channel I4.1Transmit value1 ByteCRTU
30BMG 6 T Channel I4Transmit counter value2 BytesCRTU
30BMG 6 T Channel I4Comparison value reached1 BitCRTU
30BMG 6 T Channel I4.1Switching ON/OFF1 BitCRTU
30BMG 6 T Channel I4.1Priority2 BitCRWTU
30BMG 6 T Channel I4.14 byte DPT 14.x4 BytesCRWTU
30BMG 6 T Channel I4.12 byte DPT 9.x2 BytesCRWTU
30BMG 6 T Channel I4.1Repeat 1 Byte1 ByteCRWTU
30BMG 6 T Channel I4Step / stop1 BitCRTU
31RMG 4 I channel C2Underload1 BitCRT
31RMG 8 S channel C4Logic input in XOR gate1 BitCRW
31RMG 8 S channel C4Logic input in OR gate1 BitCRW
31RMG 8 S channel C4Logic input in AND gate1 BitCRW
31DMG 2 T channel C2Brighter/darker4 BitCRWU
31JMG 4 T channel C2Cooling support1 BitCRWU
31JMG 4 T channel C2Position C1 BitCRWU
31RMG 4 U Channel C4Logic input in XOR gate1 BitCRW
31RMG 4 U Channel C4Logic input in OR gate1 BitCRW
31RMG 4 U Channel C4Logic input in AND gate1 BitCRW
31HMG 6 T Channel H3Heat & cool actuating values1 ByteCRT
31HMG 6 T Channel H3Heating actuating value1 ByteCRT
31RMG 8 T Channel C4Logic input in XOR gate1 BitCRW
31RMG 8 T Channel C4Logic input in OR gate1 BitCRW
31RMG 8 T Channel C4Logic input in AND gate1 BitCRW
31RMG 8 T Channel C4Step / stop1 BitCRWU
31BMG 6 T Channel I4Darker4 BitCRTU
31BMG 6 T Channel I4Brighter4 BitCRTU
31BMG 6 T Channel I4Darker4 BitCRWTU
31BMG 6 T Channel I4Brighter4 BitCRWTU
31BMG 6 T Channel I4Brighter/darker4 BitCRTU
31BMG 6 T Channel I4.2Transmit value1 ByteCRTU
31BMG 6 T Channel I4.2Priority2 BitCRTU
31BMG 6 T Channel I4.2Switching ON/OFF1 BitCRWTU
31BMG 6 T Channel I4.2Transmit percentage1 ByteCRTU
31BMG 6 T Channel I4.24 byte DPT 14.x4 BytesCRTU
31BMG 6 T Channel I4.22 byte DPT 9.x2 BytesCRTU
31BMG 6 T Channel I4.2Switching ON/OFF1 BitCRTU
31BMG 6 T Channel I4DOWN1 BitCRTU
31BMG 6 T Channel I4UP / DOWN1 BitCRWTU
31BMG 6 T Channel I4UP1 BitCRTU
31BMG 6 T Channel I4Current counter value2 BytesCRTU
32RMG 4 I channel C2Contact error1 BitCRTU
32RMG 8 S channel C4Lock1 BitCRW
32DMG 2 T channel C2Dimming value1 ByteCWU
32JMG 4 T channel C2Room temperature2 BytesCRWU
32RMG 4 U Channel C4Lock1 BitCRW
32HMG 6 T Channel H3Cooling actuating value1 ByteCRT
32RMG 8 T Channel C4Lock1 BitCRW
32RMG 8 T Channel C4% Height1 ByteCRWU
32BMG 6 T Channel I4.1Transmit percentage1 ByteCRTU
32BMG 6 T Channel I4.1Transmit value1 ByteCRTU
32BMG 6 T Channel I4.1Switching ON/OFF1 BitCRWTU
32BMG 6 T Channel I4.34 byte DPT 14.x4 BytesCRTU
32BMG 6 T Channel I4.32 byte DPT 9.x2 BytesCRTU
32BMG 6 T Channel I4.3Priority2 BitCRTU
32BMG 6 T Channel I4.3Switching ON/OFF1 BitCRWTU
32BMG 6 T Channel I4.3Transmit percentage1 ByteCRTU
32BMG 6 T Channel I4.3Transmit value1 ByteCRTU
32BMG 6 T Channel I4.3Switching ON/OFF1 BitCRTU
32BMG 6 T Channel I4.1Height %1 ByteCRTU
33JMG 4 T Channel C2Height feedback 1 bit1 BitCRTU
33RMG 4 I channel C2Logic input in OR gate1 BitCRW
33RMG 8 S channel C4Call up/save scenes1 ByteCRWTU
33DMG 2 T channel C2Soft switching1 BitCRWU
33JMG 4 T channel C2Height feedback %1 ByteCRTU
33RMG 4 U Channel C4Call up/save scenes1 ByteCRWTU
33HMG 6 T Channel H3Heating = 1, Cooling = 01 BitDPT.1CRW
33HMG 6 T Channel H3Heating = 0, Cooling = 11 Bit1.1 switchCRW
33HMG 6 T Channel H3Forced operation mode1 BitCRWU
33RMG 8 T Channel C4Call up/save scenes1 ByteCRWTU
33RMG 8 T Channel C4% Lamella1 ByteCRWU
33BMG 6 T Channel I4.4Transmit value1 ByteCRTU
33BMG 6 T Channel I4.4Priority2 BitCRTU
33BMG 6 T Channel I4.4Transmit percentage1 ByteCRTU
33BMG 6 T Channel I4.4Switching ON/OFF1 BitCRTU
33BMG 6 T Channel I4.2Lamella %1 ByteCRTU
34RMG 4 I channel C2Logic input in OR gate1 BitCRW
34RMG 8 S channel C4Lock scenes = 11 BitCRW
34RMG 8 S channel C4Enable scenes = 11 BitCRW
34DMG 2 T channel C2Lock1 BitCRWU
34JMG 4 T channel C2Lamella feedback %1 ByteCRTU
34RMG 4 U Channel C4Lock scenes = 11 BitCRW
34RMG 4 U Channel C4Enable scenes = 11 BitCRW
34HMG 6 T Channel H3Current setpoint value2 BytesCRWT
34RMG 8 T Channel C4Lock scenes = 11 BitCRW
34RMG 8 T Channel C4Enable scenes = 11 BitCRW
34RMG 8 T Channel C4Lock comfort/automatic1 BitCRWU
34BMG 6 T Channel I4Disable = 01 BitCRWU
34BMG 6 T Channel I4Disable = 11 BitCRWU
34BMG 6 T Channel I41 = enable counter1 BitCRWU
34BMG 6 T Channel I41 = lock counter1 BitCRWU
35RMG 8 S channel C4Feedback ON/OFF1 BitCRTU
35DMG 2 T channel C2Call up/save scenes1 ByteCRWU
35RMG 4 U Channel C4Feedback ON/OFF1 BitCRTU
35HMG 6 T Channel H3Report actuating value failure1 BitCRTU
35HMG 6 T Channel H3Report actual value failure1 BitCRTU
35RMG 8 T Channel C4Feedback ON/OFF1 BitCRTU
35RMG 8 T Channel C41 = Release1 BitCRWU
35RMG 8 T Channel C41 = Lock1 BitCRWU
35BMG 6 T Channel I4Counter reset1 BitCRWU
35BMG 6 T Channel I4Confirm alert1 BitCRWU
36RMG 8 S channel C4Operating hours feedback2 BytesCRWT
36RMG 8 S channel C4Time to next service2 BytesCRWTU
36DMG 2 T channel C2Enable scenes = 11 BitCRW
36DMG 2 T channel C2Lock scenes = 11 BitCRW
36JMG 4 T channel C2Start-up mode1 BitCRWU
36RMG 4 U Channel C4Time to next service2 BytesCRWTU
36RMG 4 U Channel C4Operating hours feedback2 BytesCRWT
36HMG 6 T Channel H4Continuous actuating value1 ByteCRWU
36HMG 6 T Channel H4Switching actuating value1 BitCRWU
36HMG 6 T Channel H4Base setpoint value2 BytesCRW
36RMG 8 T Channel C4Operating hours feedback2 BytesCRWT
36RMG 8 T Channel C4Time to next service2 BytesCRWTU
36RMG 8 T Channel C4Call up/save scenes1 ByteCRWU
37RMG 8 S channel C4Service required1 BitCRTU
37DMG 2 T channel C2Force = 01 BitCRWU
37DMG 2 T channel C2Force = 11 BitCRWU
37DMG 2 T channel C2Dimming value with forced op1 ByteCRWU
37DMG 2 T channel C2 Forced mode2 BitCRWU
37JMG 4 T channel C2Receive runtime2 BytesCRW
37JMG 4 T channel C2Send runtime2 BytesCRT
37RMG 4 U Channel C4Service required1 BitCRTU
37HMG 6 T Channel H4Manual set point offset2 BytesCRW
37RMG 8 T Channel C4Service required1 BitCRTU
37RMG 8 T Channel C4Lock scenes = 11 BitCRW
37RMG 8 T Channel C4Enable scenes = 11 BitCRW
38RMG 8 S channel C4Reset operating hours1 BitCRW
38RMG 8 S channel C4Reset service1 BitCRW
38RMG 8 S channel C4Switching with priority2 BitCRW
38DMG 2 T channel C2Dimming value limit1 ByteCRWU
38RMG 4 U Channel C4Switching with priority2 BitCRW
38RMG 4 U Channel C4Reset service1 BitCRW
38RMG 4 U Channel C4Reset operating hours1 BitCRW
38HMG 6 T Channel H4Block valve protection1 BitCRW
38HMG 6 T Channel H4Actual value2 BytesCRWU
38RMG 8 T Channel C4Reset operating hours1 BitCRW
38RMG 8 T Channel C4Reset service1 BitCRW
38RMG 8 T Channel C4Switching with priority2 BitCRW
38RMG 8 T Channel C4Priority on safety2 BitCRWU
39DMG 2 T channel C2Feedback On/Off1 BitCRTU
39HMG 6 T Channel H4Current actuating value1 ByteCRTU
39HMG 6 T Channel H4Operating mode preset1 ByteCRW
40RMG 4 I channel C3Threshold value 0..2551 ByteCRW
40RMG 4 I channel C3Threshold value in %1 ByteCRW
40RMG 4 I channel C3Thresh. value EIS 5 (DPT9.xxx)2 BytesCRW
40RMG 4 I channel C3Threshold value 0..655352 BytesCRW
40RMG 4 I channel C3Switching object1 BitCRW
40RMG 8 S channel C5Threshold value 0..2551 ByteCRW
40RMG 8 S channel C5Thresh. value EIS 5 (DPT9.xxx)2 BytesCRW
40RMG 8 S channel C5Threshold value 0..655352 BytesCRW
40RMG 8 S channel C5Threshold value in %1 ByteCRW
40RMG 8 S channel C5Switching object1 BitCRW
40DMG 2 T channel C2Feedback in %1 ByteCRTU
40JMG 4 T channel C3UP / DOWN1 BitCRWU
40HMG 6 T Channel H4Presence1 BitCRW
40RMG 8 T Channel C1Position A1 BitCRWU
40RMG 8 T Channel C5Threshold value 0..2551 ByteCRW
40RMG 8 T Channel C5Thresh. value EIS 5 (DPT9.xxx)2 BytesCRW
40RMG 8 T Channel C5Threshold value 0..655352 BytesCRW
40RMG 8 T Channel C5Threshold value in %1 ByteCRW
40RMG 8 T Channel C5Switching object1 BitCRW
40BMG 6 T Channel I5Switching ON/OFF1 BitCRWTU
40BMG 6 T Channel I5.1Priority2 BitCRTU
40BMG 6 T Channel I5.1Switching ON/OFF1 BitCRWTU
40BMG 6 T Channel I5.1Transmit percentage1 ByteCRTU
40BMG 6 T Channel I5.12 byte DPT 9.x2 BytesCRTU
40BMG 6 T Channel I5.14 byte DPT 14.x4 BytesCRTU
40BMG 6 T Channel I5.1Transmit value1 ByteCRTU
40BMG 6 T Channel I5Transmit counter value2 BytesCRTU
40BMG 6 T Channel I5Comparison value reached1 BitCRTU
40BMG 6 T Channel I5.1Switching ON/OFF1 BitCRTU
40BMG 6 T Channel I5.1Priority2 BitCRWTU
40BMG 6 T Channel I5.14 byte DPT 14.x4 BytesCRWTU
40BMG 6 T Channel I5.12 byte DPT 9.x2 BytesCRWTU
40BMG 6 T Channel I5.1Repeat 1 Byte1 ByteCRWTU
40BMG 6 T Channel I5Step / stop1 BitCRTU
41RMG 4 I channel C3Logic input in XOR gate1 BitCRW
41RMG 4 I channel C3Logic input in OR gate1 BitCRW
41RMG 4 I channel C3Logic input in AND gate1 BitCRW
41RMG 8 S channel C5Logic input in XOR gate1 BitCRW
41RMG 8 S channel C5Logic input in AND gate1 BitCRW
41RMG 8 S channel C5Logic input in OR gate1 BitCRW
41DMG 2 T channel C2Time to next service2 BytesCRWTU
41DMG 2 T channel C2Operating hours feedback2 BytesCRWT
41JMG 4 T channel C3Step / stop1 BitCRWU
41HMG 6 T Channel H4Window position1 BitCRW
41RMG 8 T Channel C1Position B1 BitCRWU
41RMG 8 T Channel C5Logic input in XOR gate1 BitCRW
41RMG 8 T Channel C5Logic input in AND gate1 BitCRW
41RMG 8 T Channel C5Logic input in OR gate1 BitCRW
41BMG 6 T Channel I5Darker4 BitCRWTU
41BMG 6 T Channel I5Brighter4 BitCRWTU
41BMG 6 T Channel I5Brighter/darker4 BitCRTU
41BMG 6 T Channel I5Darker4 BitCRTU
41BMG 6 T Channel I5Brighter4 BitCRTU
41BMG 6 T Channel I5.2Transmit value1 ByteCRTU
41BMG 6 T Channel I5.2Priority2 BitCRTU
41BMG 6 T Channel I5.2Switching ON/OFF1 BitCRWTU
41BMG 6 T Channel I5.2Transmit percentage1 ByteCRTU
41BMG 6 T Channel I5.24 byte DPT 14.x4 BytesCRTU
41BMG 6 T Channel I5.22 byte DPT 9.x2 BytesCRTU
41BMG 6 T Channel I5.2Switching ON/OFF1 BitCRTU
41BMG 6 T Channel I5UP1 BitCRTU
41BMG 6 T Channel I5DOWN1 BitCRTU
41BMG 6 T Channel I5UP / DOWN1 BitCRWTU
41BMG 6 T Channel I5Current counter value2 BytesCRTU
42RMG 8 S channel C5Lock1 BitCRW
42RMG 4 I channel C3Lock1 BitCRW
42DMG 2 T channel C2Service required1 BitCRTU
42JMG 4 T channel C3% Height1 ByteCRWU
42HMG 6 T Channel H4Current operating mode1 ByteCRT
42RMG 8 T Channel C1Position C1 BitCRWU
42RMG 8 T Channel C5Lock1 BitCRW
42BMG 6 T Channel I5.1Transmit percentage1 ByteCRTU
42BMG 6 T Channel I5.1Transmit value1 ByteCRTU
42BMG 6 T Channel I5.1Switching ON/OFF1 BitCRWTU
42BMG 6 T Channel I5.34 byte DPT 14.x4 BytesCRTU
42BMG 6 T Channel I5.32 byte DPT 9.x2 BytesCRTU
42BMG 6 T Channel I5.3Priority2 BitCRTU
42BMG 6 T Channel I5.3Switching ON/OFF1 BitCRWTU
42BMG 6 T Channel I5.3Transmit percentage1 ByteCRTU
42BMG 6 T Channel I5.3Transmit value1 ByteCRTU
42BMG 6 T Channel I5.3Switching ON/OFF1 BitCRTU
42BMG 6 T Channel I5.1Height %1 ByteCRTU
43RMG 8 S channel C5Call up/save scenes1 ByteCRWTU
43RMG 4 I channel C3Call up/save scenes1 ByteCRWTU
43DMG 2 T channel C2Reset service1 BitCRW
43DMG 2 T channel C2Reset operating hours1 BitCRW
43RMG 8 T Channel C1Height feedback 1 bit1 BitCRTU
43JMG 4 T channel C3% Lamella1 ByteCRWU
43HMG 6 T Channel H4Heat & cool actuating values1 ByteCRT
43HMG 6 T Channel H4Heating actuating value1 ByteCRT
43RMG 8 T Channel C1Height feedback %1 ByteCRTU
43RMG 8 T Channel C5Call up/save scenes1 ByteCRWTU
43BMG 6 T Channel I5.4Transmit value1 ByteCRTU
43BMG 6 T Channel I5.4Priority2 BitCRTU
43BMG 6 T Channel I5.4Transmit percentage1 ByteCRTU
43BMG 6 T Channel I5.4Switching ON/OFF1 BitCRTU
43BMG 6 T Channel I5.2Lamella %1 ByteCRTU
44RMG 4 I channel C3Enable scenes = 11 BitCRW
44RMG 8 S channel C5Lock scenes = 11 BitCRW
44RMG 8 S channel C5Enable scenes = 11 BitCRW
44RMG 4 I channel C3Lock scenes = 11 BitCRW
44DMG 2 T channel C2General error message1 BitCRTU
44JMG 4 T channel C3Lock comfort/automatic1 BitCRWU
44HMG 6 T Channel H4Cooling actuating value1 ByteCRT
44RMG 8 T Channel C1Lamella feedback %1 ByteCRTU
44RMG 8 T Channel C5Lock scenes = 11 BitCRW
44RMG 8 T Channel C5Enable scenes = 11 BitCRW
44BMG 6 T Channel I5Disable = 11 BitCRWU
44BMG 6 T Channel I5Disable = 01 BitCRWU
44BMG 6 T Channel I51 = lock counter1 BitCRWU
44BMG 6 T Channel I51 = enable counter1 BitCRWU
45RMG 8 S channel C5Feedback ON/OFF1 BitCRTU
45RMG 4 I channel C3Feedback ON/OFF1 BitCRTU
45DMG 2 T channel C2Short circuit message1 BitCRTU
45JMG 4 T channel C31 = Lock1 BitCRWU
45JMG 4 T channel C31 = Release1 BitCRWU
45HMG 6 T Channel H4Heating = 1, Cooling = 01 BitDPT.1CRW
45HMG 6 T Channel H4Heating = 0, Cooling = 11 Bit1.1 switchCRW
45HMG 6 T Channel H4Forced operation mode1 BitCRWU
45RMG 8 T Channel C5Feedback ON/OFF1 BitCRTU
45BMG 6 T Channel I5Counter reset1 BitCRWU
45BMG 6 T Channel I5Confirm alert1 BitCRWU
46RMG 4 I channel C3Operating hours feedback2 BytesCRWT
46RMG 4 I channel C3Time to next service2 BytesCRWTU
46RMG 8 S channel C5Operating hours feedback2 BytesCRWT
46RMG 8 S channel C5Time to next service2 BytesCRWTU
46DMG 2 T channel C2Excess temperature message1 BitCRTU
46JMG 4 T channel C3Call up/save scenes1 ByteCRWU
46HMG 6 T Channel H4Current setpoint value2 BytesCRWT
46RMG 8 T Channel C5Operating hours feedback2 BytesCRWT
46RMG 8 T Channel C5Time to next service2 BytesCRWTU
47RMG 4 I channel C3Service required1 BitCRTU
47RMG 8 S channel C5Service required1 BitCRTU
47DMG 2 T channel C2Mains power failure1 BitCRTU
47JMG 4 T channel C3Lock scenes = 11 BitCRW
47JMG 4 T channel C3Enable scenes = 11 BitCRW
47HMG 6 T Channel H4Report actuating value failure1 BitCRTU
47HMG 6 T Channel H4Report actual value failure1 BitCRTU
47RMG 8 T Channel C5Service required1 BitCRTU
48RMG 4 I channel C3Reset operating hours1 BitCRW
48RMG 4 I channel C3Reset service1 BitCRW
48RMG 4 I channel C3Switching with priority2 BitCRW
48RMG 8 S channel C5Reset operating hours1 BitCRW
48RMG 8 S channel C5Reset service1 BitCRW
48RMG 8 S channel C5Switching with priority2 BitCRW
48DMG 2 T channel C2Load type message (R, C/L)1 BitCRTU
48JMG 4 T channel C3Priority on safety2 BitCRWU
48HMG 6 T Channel H5Continuous actuating value1 ByteCRWU
48HMG 6 T Channel H5Switching actuating value1 BitCRWU
48HMG 6 T Channel H5Base setpoint value2 BytesCRW
48RMG 8 T Channel C5Reset operating hours1 BitCRW
48RMG 8 T Channel C5Reset service1 BitCRW
48RMG 8 T Channel C5Switching with priority2 BitCRW
49RMG 4 I channel C3Current value2 BytesCRTU
49RMG 4 I channel C3Theoretical power2 BytesCRTU
49JMG 4 T channel C3Presence1 BitCRW
49JMG 4 T channel C3Position A1 BitCRWU
49HMG 6 T Channel H5Manual set point offset2 BytesCRW
50RMG 8 S channel C6Threshold value 0..2551 ByteCRW
50RMG 8 S channel C6Thresh. value EIS 5 (DPT9.xxx)2 BytesCRW
50RMG 8 S channel C6Threshold value 0..655352 BytesCRW
50RMG 8 S channel C6Threshold value in %1 ByteCRW
50RMG 8 S channel C6Switching object1 BitCRW
50RMG 4 I channel C3Overload1 BitCRT
50JMG 4 T channel C3Heating support1 BitCRWU
50JMG 4 T channel C3Position B1 BitCRWU
50HMG 6 T Channel H5Block valve protection1 BitCRW
50HMG 6 T Channel H5Actual value2 BytesCRWU
50RMG 8 T Channel C2Position A1 BitCRWU
50RMG 8 T Channel C6Threshold value 0..2551 ByteCRW
50RMG 8 T Channel C6Thresh. value EIS 5 (DPT9.xxx)2 BytesCRW
50RMG 8 T Channel C6Threshold value 0..655352 BytesCRW
50RMG 8 T Channel C6Threshold value in %1 ByteCRW
50RMG 8 T Channel C6Switching object1 BitCRW
50BMG 6 T Channel I6Switching ON/OFF1 BitCRWTU
50BMG 6 T Channel I6.1Priority2 BitCRTU
50BMG 6 T Channel I6.1Switching ON/OFF1 BitCRWTU
50BMG 6 T Channel I6.1Transmit percentage1 ByteCRTU
50BMG 6 T Channel I6.12 byte DPT 9.x2 BytesCRTU
50BMG 6 T Channel I6.14 byte DPT 14.x4 BytesCRTU
50BMG 6 T Channel I6.1Transmit value1 ByteCRTU
50BMG 6 T Channel I6Transmit counter value2 BytesCRTU
50BMG 6 T Channel I6Comparison value reached1 BitCRTU
50BMG 6 T Channel I6.1Switching ON/OFF1 BitCRTU
50BMG 6 T Channel I6.1Priority2 BitCRWTU
50BMG 6 T Channel I6.14 byte DPT 14.x4 BytesCRWTU
50BMG 6 T Channel I6.12 byte DPT 9.x2 BytesCRWTU
50BMG 6 T Channel I6.1Repeat 1 Byte1 ByteCRWTU
50BMG 6 T Channel I6Step / stop1 BitCRTU
51RMG 4 I channel C3Underload1 BitCRT
51RMG 8 S channel C6Logic input in OR gate1 BitCRW
51RMG 8 S channel C6Logic input in XOR gate1 BitCRW
51RMG 8 S channel C6Logic input in AND gate1 BitCRW
51JMG 4 T channel C3Cooling support1 BitCRWU
51JMG 4 T channel C3Position C1 BitCRWU
51HMG 6 T Channel H5Current actuating value1 ByteCRTU
51HMG 6 T Channel H5Operating mode preset1 ByteCRW
51RMG 8 T Channel C2Position B1 BitCRWU
51RMG 8 T Channel C6Logic input in OR gate1 BitCRW
51RMG 8 T Channel C6Logic input in XOR gate1 BitCRW
51RMG 8 T Channel C6Logic input in AND gate1 BitCRW
51BMG 6 T Channel I6Darker4 BitCRWTU
51BMG 6 T Channel I6Brighter4 BitCRWTU
51BMG 6 T Channel I6Brighter/darker4 BitCRTU
51BMG 6 T Channel I6Darker4 BitCRTU
51BMG 6 T Channel I6Brighter4 BitCRTU
51BMG 6 T Channel I6.2Transmit value1 ByteCRTU
51BMG 6 T Channel I6.2Priority2 BitCRTU
51BMG 6 T Channel I6.2Switching ON/OFF1 BitCRWTU
51BMG 6 T Channel I6.2Transmit percentage1 ByteCRTU
51BMG 6 T Channel I6.24 byte DPT 14.x4 BytesCRTU
51BMG 6 T Channel I6.22 byte DPT 9.x2 BytesCRTU
51BMG 6 T Channel I6.2Switching ON/OFF1 BitCRTU
51BMG 6 T Channel I6UP1 BitCRTU
51BMG 6 T Channel I6DOWN1 BitCRTU
51BMG 6 T Channel I6UP / DOWN1 BitCRWTU
51BMG 6 T Channel I6Current counter value2 BytesCRTU
52RMG 8 S channel C6Lock1 BitCRW
52RMG 4 I channel C3Contact error1 BitCRTU
52JMG 4 T channel C3Room temperature2 BytesCRWU
52HMG 6 T Channel H5Presence1 BitCRW
52RMG 8 T Channel C2Position C1 BitCRWU
52RMG 8 T Channel C6Lock1 BitCRW
52BMG 6 T Channel I6.1Transmit percentage1 ByteCRTU
52BMG 6 T Channel I6.1Transmit value1 ByteCRTU
52BMG 6 T Channel I6.1Switching ON/OFF1 BitCRWTU
52BMG 6 T Channel I6.34 byte DPT 14.x4 BytesCRTU
52BMG 6 T Channel I6.32 byte DPT 9.x2 BytesCRTU
52BMG 6 T Channel I6.3Priority2 BitCRTU
52BMG 6 T Channel I6.3Switching ON/OFF1 BitCRWTU
52BMG 6 T Channel I6.3Transmit percentage1 ByteCRTU
52BMG 6 T Channel I6.3Transmit value1 ByteCRTU
52BMG 6 T Channel I6.3Switching ON/OFF1 BitCRTU
52BMG 6 T Channel I6.1Height %1 ByteCRTU
53JMG 4 T Channel C3Height feedback 1 bit1 BitCRTU
53RMG 4 I channel C3Logic input in OR gate1 BitCRW
53RMG 8 S channel C6Call up/save scenes1 ByteCRWTU
53RMG 8 T Channel C2Height feedback 1 bit1 BitCRTU
53JMG 4 T channel C3Height feedback %1 ByteCRTU
53HMG 6 T Channel H5Window position1 BitCRW
53RMG 8 T Channel C2Height feedback %1 ByteCRTU
53RMG 8 T Channel C6Call up/save scenes1 ByteCRWTU
53BMG 6 T Channel I6.4Transmit value1 ByteCRTU
53BMG 6 T Channel I6.4Priority2 BitCRTU
53BMG 6 T Channel I6.4Transmit percentage1 ByteCRTU
53BMG 6 T Channel I6.4Switching ON/OFF1 BitCRTU
53BMG 6 T Channel I6.2Lamella %1 ByteCRTU
54RMG 4 I channel C3Logic input in OR gate1 BitCRW
54RMG 8 S channel C6Lock scenes = 11 BitCRW
54RMG 8 S channel C6Enable scenes = 11 BitCRW
54JMG 4 T channel C3Lamella feedback %1 ByteCRTU
54HMG 6 T Channel H5Current operating mode1 ByteCRT
54RMG 8 T Channel C2Lamella feedback %1 ByteCRTU
54RMG 8 T Channel C6Lock scenes = 11 BitCRW
54RMG 8 T Channel C6Enable scenes = 11 BitCRW
54BMG 6 T Channel I6Disable = 01 BitCRWU
54BMG 6 T Channel I6Disable = 11 BitCRWU
54BMG 6 T Channel I61 = enable counter1 BitCRWU
54BMG 6 T Channel I61 = lock counter1 BitCRWU
55RMG 8 S channel C6Feedback ON/OFF1 BitCRTU
55HMG 6 T Channel H5Heating actuating value1 ByteCRT
55HMG 6 T Channel H5Heat & cool actuating values1 ByteCRT
55RMG 8 T Channel C6Feedback ON/OFF1 BitCRTU
55BMG 6 T Channel I6Counter reset1 BitCRWU
55BMG 6 T Channel I6Confirm alert1 BitCRWU
56RMG 8 S channel C6Operating hours feedback2 BytesCRWT
56RMG 8 S channel C6Time to next service2 BytesCRWTU
56JMG 4 T channel C3Start-up mode1 BitCRWU
56HMG 6 T Channel H5Cooling actuating value1 ByteCRT
56RMG 8 T Channel C6Operating hours feedback2 BytesCRWT
56RMG 8 T Channel C6Time to next service2 BytesCRWTU
57RMG 8 S channel C6Service required1 BitCRTU
57JMG 4 T channel C3Receive runtime2 BytesCRW
57JMG 4 T channel C3Send runtime2 BytesCRT
57HMG 6 T Channel H5Heating = 1, Cooling = 01 BitDPT.1CRW
57HMG 6 T Channel H5Heating = 0, Cooling = 11 Bit1.1 switchCRW
57HMG 6 T Channel H5Forced operation mode1 BitCRWU
57RMG 8 T Channel C6Service required1 BitCRTU
58RMG 8 S channel C6Reset operating hours1 BitCRW
58RMG 8 S channel C6Reset service1 BitCRW
58RMG 8 S channel C6Switching with priority2 BitCRW
58HMG 6 T Channel H5Current setpoint value2 BytesCRWT
58RMG 8 T Channel C6Reset operating hours1 BitCRW
58RMG 8 T Channel C6Reset service1 BitCRW
58RMG 8 T Channel C6Switching with priority2 BitCRW
59HMG 6 T Channel H5Report actuating value failure1 BitCRTU
59HMG 6 T Channel H5Report actual value failure1 BitCRTU
60RMG 8 S channel C7Threshold value 0..2551 ByteCRW
60RMG 8 S channel C7Thresh. value EIS 5 (DPT9.xxx)2 BytesCRW
60RMG 8 S channel C7Threshold value 0..655352 BytesCRW
60RMG 8 S channel C7Threshold value in %1 ByteCRW
60RMG 8 S channel C7Switching object1 BitCRW
60RMG 4 I channel C4Threshold value 0..2551 ByteCRW
60RMG 4 I channel C4Thresh. value EIS 5 (DPT9.xxx)2 BytesCRW
60RMG 4 I channel C4Threshold value in %1 ByteCRW
60RMG 4 I channel C4Threshold value 0..655352 BytesCRW
60RMG 4 I channel C4Switching object1 BitCRW
60JMG 4 T channel C4UP / DOWN1 BitCRWU
60HMG 6 T Channel H6Continuous actuating value1 ByteCRWU
60HMG 6 T Channel H6Switching actuating value1 BitCRWU
60HMG 6 T Channel H6Base setpoint value2 BytesCRW
60RMG 8 T Channel C7Threshold value 0..2551 ByteCRW
60RMG 8 T Channel C7Thresh. value EIS 5 (DPT9.xxx)2 BytesCRW
60RMG 8 T Channel C7Threshold value 0..655352 BytesCRW
60RMG 8 T Channel C7Threshold value in %1 ByteCRW
60RMG 8 T Channel C7Switching object1 BitCRW
60RMG 8 T Channel C3Position A1 BitCRWU
60BMG 6 T Channel C1Switching ON/OFF1 BitCRWTU

First 1000 of 4230 group objects shown. Download the .knxprod for the full list.

Parameters (594)
ParameterTypeDefault
No. Of general parametersunsignedInt 1…33
Download 101listyes
Object link RMG8 invisiblelist
Object link RMG 4 I invisiblelist
-listLink HMG 6 T
-list-
-unsignedInt 1…11
Type of basic modulelistselect device..
Type of first extension modulelistnot available/inactive
Type of second extension modulelistnot available/inactive
Time for cycl. Transm. of feedback obj. (MIX 1 series, order no.491...)list15 min.
Function of manual push button (MIX 2 series, order no.493...)listvalid until reset via object
Manual operation of channels (MIX 2 series, order no.493...)listenabled
Object link 1. RME 8 invisiblelist
Object link 1. RME 4 S 210 invisiblelist
Object link 1. DME 2 210 invisiblelist
Object link 1. BME 6 210 invisiblelist
Object link 1.HME 4 210 invisiblelist
Object link 1.JME 4 S 210 invisiblelist
Object link 1. RME 4 I invisiblelist
Channel functionlistHeating actuator
-listBMG 6 T
Type of actuating valuelistContinuous..
Include in summer modelistno
Activate valve protectionlistyes
Valve protection disable telegramlist1 = Block (standard)
Execute valve protectionlistAlways
Monitoring actuating valuelistno
Monitor actual valuelistno
Activate compulsory functionlistno
Sensitivity of the inputlistnormal
Object link 2. RME 4 S 310 invisiblelist
Object link 2. DME 2 310 invisiblelist
Object link 2. BME 6 310 invisiblelist
Object link 2.HME 4 310 invisiblelist
Object link 2.JME 4 S 310 invisiblelist
Object link 2. RME 8 invisiblelist
Object link 2. RME 4 I invisiblelist
Input functionlistpush button..
Debounce timelist50 ms
Lock telegram (if used)listlock with 1 (standard)
Long keystroke starting fromlist300 ms
Counting atlistfalling edge
Reaction when setting the locklistignore lock
Function of the input objectlistLock
Reaction when unlockinglistno reaction
Response during bus or mains restorationlistnone
Save meter reading in the event of bus and mains failurelistyes
Controlliststandard
Reaction when unlockinglistnone
Additional functions with double-clicklistno
Reset meter reading at downloadlistno
Control functions usedlistOnly heating control
Setting the control parameterslistVia installation type
Proportional band of heating controllist2 K
Connected push buttonlistNO contact
System typelistRadiator heating system
Integrated time of heating controllist10 hrs
Use channel as fault indicator inputlistno
OperationlistUP
Reaction to long / shortlistsingle-button operation
Object 1 typelistpercentage value (1 byte)
Report faultlistwith rising edge
Movement is stopped bylistbrief operation
Increment for dimmerlist100%
Time for double-clicklist300 ms
Confirmation mandatorylistno
Object 2 typelistswitching (1-bit)
Send heating actuating valuelistWith change of 5 %
Send current actuating valuelistWith change of 5 %
Effect of the confirmation objectlistconfirm with 1
Object 3 typelistswitching (1-bit)
Transmission of central feedbacklistno
Send heating actuating value in cycleslistNot cyclical, only in the event of change
Send current actuating value in cycleslistNot cyclical, only in the event of change
Function Channel C1listswitch actuator
Update after confirmation if error still presentlist1 h
Cycle timelist15 min.
Object 4 typelistpercentage value (1 byte)
Time for cyclical transmission of collective feedbacklist2 min.
Relay switching delaylistnone
Activate lock functionlistno
Function Channel C2listswitch actuator
Sequence detailsliststep 1-2-3-4-1-2-3-4
Save object value in the event of bus and mains failurelistyes
With a long button pushlistset on step 1
Delete object value at downloadlistyes
Function Channel C3listswitch actuator
Response after bus and mains restorationlistnone
Base setpoint value after loading the applicationlist21 °C
Object typelistswitching (1-bit)
Object typelist1 bit (e.g. switching)
Reduction in standby mode (during heating)list1.5 K
Function Channel C4listswitch actuator
After short operationlistsend telegram
Nach kurzer Bedienunglistrepeat last telegram
Send if input = 1 (or fault active)listyes
Reduction in night mode (during heating)list5 K
Telegramlistinactive
ValuesignedInt -999…9990
TelegramlistON
Telegramlist100%
ValuesignedInt -999…99922
TelegramunsignedInt 0…255255
TelegramlistOFF
Telegramlist0%
TelegramunsignedInt 0…2551
Heightlist0%
ValuesignedInt -999…99925
TelegramunsignedInt 0…25525
Setpoint value for frost protection operation (during heating)list5 °C
Function Channel C5listallocated to C1 blind actuator
Function Channel C5listswitch actuator
PrescalerunsignedInt 1…10001
Factorlist1
Lamellalist75%
Setpoint offset applieslistIn comfort, standby and night mode
Current setpoint value in comfort modelistSends actual value (heating < > cooling)
Counter typelistevent counter
Transmit telegram cyclicallylistno
Send current setpoint value in cycleslistNot cyclical, only in the event of change
Maximum valid setpoint offsetlist+/- -5 K
Function Channel C6listallocated to C2 blind actuator
Function Channel C6listswitch actuator
Comparator valueunsignedInt 1…100010
Transmit counter status everyunsignedInt 1…100010
After long operationlistdo not send
Cycle timelist30 min.
Send if input = 0 (or fault inactive)listyes
Minimum valid base setpoint valuelist10 °C
Transmit counter status cyclicallylistno
Telegram once the Comparator value is reachedlistON otherwise OFF
Telegramlist25%
Maximum valid base setpoint valuelist32 °C
Function Channel C7listswitch actuator
Function Channel C7listallocated to C3 blind actuator
Function Channel C8listswitch actuator
Function Channel C8listallocated to C4 blind actuator
After double-clicklistdo not send
Send collective feedback (Only switching actuator channels)listno
TelegramlistTOGGLE
Telegramlist50%
TelegramunsignedInt 0…2550
Send object 1listno
Send object 2listno
Send a second telegram?listno
Send object 3listno
Telegramlist75%
After short operationlistdo not send
Send object 4listno
Proportional band of the cooling controllist4 K
System typelistCooling surface
Integrated time of the cooling controllist180 min.
Send cooling actuating valuelistWith change of 5 %
Send the cooling actuating value in cycleslistNot cyclical, only in the event of change
Send object 1listyes
Switchover between heating and coolinglistautomatic
ValuesignedInt -999…99950
Telegramlist30%
Format object heating/coolinglistDPT100 (Heating= 1 / Cooling=0)
Output of the cooling actuating valuelistOn separate object
TelegramunsignedInt 0…255128
TelegramunsignedInt 0…25550
Send a third telegram?listno
Dead zone between heating and coolinglist2 K
Increase in standby mode (during cooling)list1.5 K
Increase in night mode (during cooling)list5 K
Setpoint value for heat protection mode (during cooling)list42 °C i.e. no real heat protection
ValuesignedInt -999…99975
TelegramunsignedInt 0…25575
Channel functionlistSwitching ON/OFF
Adjust dimming value limitslistno
Channel functionlistshutters/blinds
-listshutters/blinds
Function activated bylistSwitching object
Adjust soft switchinglistno
Type of motorlistelectromechanical
Operating mode after resetlistStandby
Drive applicationlistblinds..
Adjust lock functionlistno
Setting the drive runtimelistvia ETS
Type of presence sensorlistPresence detector
Activate forced modelistno
Response after downloadlistmaintain runtime
Comfort extension by presence buttons in night modelist2 hours
Activate sceneslistno
Activate sun protection modelistno
Lock Comfort/Auto on UP/DOWN/STOP command (dev. from 08.2016)listno, only via object Comfort/Automatic
Format feedback height (dev. from 08.2016)list%
Participation in central objectslistno
Direction of drive runlistnormal
Set feedbacklistno
Adjust feedbacklistno
Complete runtime Down (s)unsignedInt 5…50050
Activate hour meterlistno
Runtime adjustment for ascent (s)signedInt -15…150
Activate diagnostic messageslistno
Send the current operating mode in cycleslistNot cyclical, only in the event of change
Step duration of Step/Stop objectlist1 s
Complete lamella turn (x 100 ms)unsignedInt 4…25010
Tighten fabric (awnings)listno
No. of steps for a complete turnlist7 steps
Lock telegramlistlock with 1 (standard)
On receipt of a step/stop commandlistprocess immediately (recommended)
1111 Switching functionlistdefault value - dummy
1301 Switching functionlistdefault value - dummy
Pause time before reversal of directionlist0.5 s
Activate logic linklistno
Automatic execution of lamella object value (%) after the height object (%)listyes
Reaction when unlockinglistupdate
Allocation of 0% position to slat object [%]list0% corresponds to slats position on lowering
Participation in central UP/DOWN objectlistyes
Transmission of feedbacklistonly at change
Time for cyclical transmission of feedbacklist15 min.
TelegramunsignedInt 0…255100
Lock telegramlistLock with ON telegram
Response when setting the locklistunchanged (stopped upon command)
Type of contactlistNO contact
Load selectionlistautomatic
Channel processes actuating value forlistHeating
Response when cancelling the locklistupdate (height / lamella)
LED Lamps (RC)listdefault value - dummy
*** 10 % point in 100 µs (Standard=24)unsignedInt 15…9324
*** 20 % point in 100 µs (Standard=31)unsignedInt 15…9331
*** 30 % point in 100 µs (Standard=36)unsignedInt 15…9336
*** 40 % point in 100 µs (Standard=41)unsignedInt 15…9341
*** 50 % point in 100 µs (Standard=46)unsignedInt 15…9346
*** 60 % point in 100 µs (Standard=51)unsignedInt 15…9351
*** 70 % point in 100 µs (Standard=56)unsignedInt 15…9356
*** 80 % point in 100 µs (Standard=63)unsignedInt 15…9363
*** 90 % point in 100 µs (Standard=75)unsignedInt 15…9375
*** Start-up valuelist50 %
ATTENTION: USE ONLY AFTER DISCUSSING WITH HOTLINE!listRC mode SET PERMANENTLY!
*** Type of loadlistRC
*** Start-up time (unit)list20 ms
Start-up timelist10 s
*** Start-up time (factor)unsignedInt 0…12750
Status at download and bus failurelistOFF
Status at download and bus failurelistunchanged
PWM Einheit - SPÄTER UNSICHTBAR -listMinutes
*** 100 % point in 100 µs (Standard=100)list100 % = limited to the 90 % setting
Minimum dimming valuelist10 %
Status at restoration of mains or bus powerlistOFF
Status at restoration of mains or bus powerlistsame as before failure
Dimming time 1 from 0% to 100%list4 s
Actuation cycle time (PWM period)list10 min.
Actuation cycle time (PWM period) for emergency program and forced operationlist10 min.
Priority of safety objectslist1. Wind 2. Rain, 3. Frost
Dimming time 2 from 0% to 100%list8 s
Actuator direction of operationlistStandard: 1 = Open valve (Theben actuator)
Monitor safety objects cyclicallylistno
Dimming time 3 from 0% to 100%list12 s
Minimum actuating valuelist0%
Participation in safety WINDlistno
When receiving a switching order (1 bit)listsoft on with dimming time 1
Maximum actuating valuelist90%
Source(s)listsafety object 1 + 2 +3 (OR linked)
When receiving a dimming order (4 bit)listsoft on with dimming time 1
Actuating value when value violates the min./max. actuating valuelist0 = 0%, otherwise use set actuating values
Startlisttop end position
When receiving an absolute value (8 bit)listsoft on with dimming time 1
Endlistsame as before safety
Switch-on valuelistbrightness value before previous switch-OFF
Take channel H1 into account for highest actuating valuelistyes
Participation in safety RAINlistno
Switching ON/OFF with a 4-bit dim telegramlistyes
Consider Channel H1 for pump controllistyes
1301 Pulse functionlistdefault value - dummy
1301 ON/OFF delay functionlistdefault value - dummy
1301 Stairway light functionlistdefault value - dummy
1301 Flashing functionlistdefault value - dummy
Desired room temperature during sun protection modelist21 °C
Hours (0..3)unsignedInt 0…30
Response to presence in sun protection mode (presence object = 1)listupdate (height / lamella)
Participation in safety FROSTlistno
Minutes (0..60)unsignedInt 0…600
Response to heating supportlisttop end position
Seconds (0..255)unsignedInt 0…2551
Response when heating support is no longer neededlistno reaction, unchanged
Pulse can be retriggered (via 1 to switching object)listno
Max. cumulated pulses 1..40unsignedInt 1…405
Response to cooling supportlistbottom end position
Response after priority on safetylistno reaction, unchanged
Pulse can be reset (with 0 on switching object)listno
Duration of first warning in s (0..60)unsignedInt 0…6010
Response when cooling support is no longer neededlistno reaction, unchanged
Duration of second warning in s (0..60)unsignedInt 0…6030
Heightlist0 %
Seconds (0..255)unsignedInt 0…2550
Lamellalist100 %
How often should it flashlist3 x
Heightlist40 %
Type of threshold value objectlistobject type: percentage (dpt5.001)
Perform limitation when writing objectlistno
Lower threshold value format: (-)0,00..99999text20,0
Lower threshold value (in %)unsignedInt 1…9950
ThresholdunsignedInt 1…254127
ThresholdunsignedInt 1…655341000
Limit applies to soft switchinglistno
Limit applies to switching command (1-bit)listno
Lower threshold value format: (-)0,00..99999text20,0
Lower threshold valueunsignedInt 1…254127
Lower threshold valueunsignedInt 1…655341000
Hysteresis format: 0,00..9999text1,0
Hysteresis (in %)unsignedInt 1…9910
HysteresisunsignedInt 1…2545
HysteresisunsignedInt 1…655345
Limit applies to absolute dimming (8-bit)listno
Limit applies to relative dimming (4-bit)listno
Heightlist50 %
Response at exceeding thresholdlistas switching object = 1
Actuating value for emergency program islistAmbient temperature dependent
Emergency program active when outside temperature belowlist10 °C
Fixed emergency program in winter modelist20%
Heightlist60 %
Max. actuating value in emergency programlist40%
Fixed emergency program with failure of outside temperaturelist20%
Heightlist70 %
Heightlist80 %
Response when setting the locklistunchanged
Response when cancelling the locklistunchanged
Response when cancelling the locklistupdate
Heightlist90 %
Heightlist100 %
Lock telegram for sceneslistLock with ON telegram
All scene statuses of channellistoverwrite when downloading
Participation in object Central scenelistno
Channel reacts tolistscene number 1
Time for Soft ONlist1 min
Actuating value in the forced operation modelist0%
Status after downloadlistOFF
Permit teach-inlistyes
Channel reacts tolistscene number 2
Dimming value after Soft ONlist100 %
Forced telegramlist1 = Force (standard)
Channel reacts tolistscene number 3
Time between Soft ON and Soft OFFlist5 min.
Response when unlocking the scene (with scene value 63)listno reaction
Channel reacts tolistscene number 4
Time for Soft OFFlist1 min
Channel reacts tolistscene number 1 (value = 0)
Comment for this scene numbertext[Name]
Channel reacts tolistscene number 5
Lock comfort/automatic during this scenelistno
Channel reacts tolistscene number 6
Cycle timelist5 min.
Object 4 typelistswitching (1-bit)
Channel reacts tolistscene number 2 (value = 1)
Channel reacts tolistscene number 7
Channel reacts tolistscene number 8
Channel reacts tolistscene number 3 (value = 2)
Reported statuslistnot inverted
Channel reacts tolistscene number 4 (value = 3)
Transmit feedback cyclicallylistno
Heightlist50%
Channel reacts tolistscene number 5 (value = 4)
Lamellalist25%
Channel reacts tolistscene number 6 (value = 5)
Channel reacts tolistscene number 7 (value = 6)
Type of hour meterlistoperating hours counter
Channel reacts tolistscene number 8 (value = 7)
Service interval (0..2000, x 10 h)unsignedInt 0…2000100
Response when setting the locklist10 %
Report operating hours at change (0..100 h, 0 = no report)unsignedInt 0…10010
Report time to service when changed (0..100 h, 0 = no report)unsignedInt 0…10010
Transmit operating hours cyclicallylistno
Transmit time to service cyclicallylistno
Response when receiving a 1listtop end position
Response when receiving a 0listno reaction
Report service cyclicallylistno
Time for cyclical transmissionlist60 min
Time for cyclical transmission (time to service)list60 min
Activate logic linklistAND-link
Lock object affects link objectlistno
Response in the event of download and bus failurelistno reaction
Response when bus or mains power restoredlistno reaction
Copy main parameters from channel C1listno
-listno
Format of forced objectlist1 bit
Activate forced mode withlist1
Behaviour at start of forced mode operationlistno change
Reaction on forced ONlistno change
Behaviour at end of forced modelistvalue before forced mode
Reaction on forced OFFlistOFF
Activate current meteringlistno
2111 Switching functionlistdefault value - dummy
Allocated dimming valuelist10 %
Response when receiving scene numberslistsoft on with dimming time 1
Allocated dimming valuelist20 %
Allocated dimming valuelist30 %
Allocated dimming valuelist40 %
Allocated dimming valuelist50 %
Allocated dimming valuelist60 %
Allocated dimming valuelist70 %
Allocated dimming valuelist80 %
2301 Flashing functionlistdefault value - dummy
2301 Pulse functionlistdefault value - dummy
2301 ON/OFF delay functionlistdefault value - dummy
2301 Stairway light functionlistdefault value - dummy
Comment for this scene numbertext[Name eingeben]
Format of 1-bit feedbacklistnot inverted
Send 1-bit feedback cyclicallylistno
Send 8-bit feedbacklistonly after ending dimming process
Send 8-bit feedback cyclicallylistno
Time for cyclical transmission of feedback(if available)list60 min
Status at download and bus failurelistsame as before failure
Take channel H2 into account for highest actuating valuelistyes
Take channel H2 into account for pump controllistyes
Transmit current value at changelistno
Transmit current value cyclicallylistno
Conversion of current into theoretical powerlistno
Conversion: Power = Current x factor (Factor = Tension x cos phi)unsignedInt 0…2550
Conversion: Power = Current x factor (Factor = Tension x cos phi)unsignedInt 1…2551
Transmit contact errors cyclically (current through open contact)listno
Delaying measurement after switching the contact (0..60 s)unsignedInt 0…603
Overload monitoringlistno
Threshold for overload (1..200) x 100 mAunsignedInt 1…2001
Hysteresis for overload (10..100 %)unsignedInt 10…10010
Minimum duration for overloadlist2 s
Telegram at overloadlistON telegram
Telegram at no overloadlistno telegram
Transmit overload cyclicallylistno
Underload monitoringlistno
Threshold value for underload (1..200) x 100 mAunsignedInt 1…2001
Hysteresis for underload (10.. 100 %)unsignedInt 10…10010
Minimum duration for underloadlist2 s
Telegram at underloadlistON telegram
Telegram at no underloadlistno telegram
Transmit underload cyclicallylistno
Time for cyclical transmission (current value,contact error, load monitoring)list60 min
Send general error cyclicallylistno
Send short circuit cyclicallylistno
Send excess temperature cyclicallylistno
Send mains failure cyclicallylistno
Send load type cyclicallylistno
Send status cyclically (bit set)listno
Cycle time for all diagnostic messages (if used)list60 min
Permit teach-inlistno
*** 100 % point in 100 µs (Standard=100)list100 (10 ms)
2301 Switching functionlistdefault value - dummy
Take channel H3 into account for highest actuating valuelistyes
Take channel H3 into account for pump controllistyes
Time for cyclical transmission of feedback(if available)list60 min
Take channel H4 into account for highest actuating valuelistyes
Take channel H4 into account for pump controllistyes
-listWith change of 5 %
Functionlistpush button..
Entprellzeitlist50 ms
Angeschlossener TasterlistNO contact
-list100%
Maximum actuating valuelist100%
Take channel H5 into account for highest actuating valuelistno
Take channel H5 into account for pump controllistyes
Positionlist80 %
Take channel H6 into account for highest actuating valuelistno
Take channel H6 into account for pump controllistyes
Monitoring timelist30 min.
Status of monitoringlistReport only in the event of malfunction
Send status in cycleslistno
Cycle timelistEvery 30 min.
Switch pump ON only when at least (only for devices from 10.2016)listone input actuating value is > 0 %
Switch-off delay for pumplist10 min.
Send pump control in cycleslistno, only in the event of change
Send highest actuating value in cycles (If continuous actuating value used)listno, only in the event of change
-listLink 1. HME 6 T
Activate valve protectionlistno
Transmit telegram cyclicallylistyes
Safety objects 1-3listwithout cycl. monitoring
Auto. execution of slat object value [%] after the height [%] objectlistno
Permit use of push buttons on devicelistyes
ValuesignedInt -999…999100
Channel functionlistswitching ON/OFF..
Input functionlistswitch / push button..
Summer modelistno
Participation in central UP/DOWN objectlistno
Participation in sceneslistno
Valve protectionlistyes
React to safety:listno
Linklistno
11050 Transmit response cycl. INVISIBLElistno
Activate response at actuating value failurelistno
Linklistnone
Activate soft dimminglistno
Activate feedbacklistno
Load selection (R,C or L): ONLY for DME 2 Slistautomatic load detection (standard)
Complete slats turn 20 ... 250 [x10ms]unsignedInt 20…250100
Step duration of Step/Stop objectlist3 s
React to rising edgelistyes
Value range for complete runtime uplist5..255 s
Runtime [x 1s]unsignedInt 5…25550
Runtime [x 1s] = 256 +unsignedInt 0…2440
3 = noneunsignedInt 0…33
SwitchinglistON
minimum brightnesslist35 %
Type of valuelistpercentage value
Actuator responselistheated at switch-ON (theben actuator)
Approaching positions via the bottom position (shutter/awning)listapproach directly
React to falling edgelistyes
Basis for ON or OFF time delaylist1 min
Basis for staircase light timelist1 min

First 500 of 594 parameters shown. Download the .knxprod for the full list.

Version history

ApplicationApp noFingerprintFirst seenSizeFile
MIX 2 secure 2.1 latest$493BB4712026-11-25543 KBDownload
MIX 2 V1.C (1.12) 1.12$493AE04E2026-11-253.5 MBDownload

About this file

This is the official ETS product database for the Theben AG HMG 6 T (4930240), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Theben AG

All Theben AG products