KNX Database
Theben AG 4940240 HM 6 T

HM 6 T 4940240

Theben AG · Order number 4940240 · Heizungsaktoren › HM 6 T

6-way heating actuator FIX1

Download .knxprod FIX2 HM 12 T 1.4 · 240 KB

Product

ManufacturerTheben AG
Product nameHM 6 T
Order number4940240
Product textHM 6 T (6-way heating actuator)
HardwareFIX1-SERIES HM 6 T
MediumTwisted Pair
Bus current (mA)5
Rail mountedYes
Width (mm)72
RegistrationCertified · 2018-04-20
Languagesde-DE, en-US, es-ES, fr-FR, it-IT, nl-NL
Catalog entryM-0048_H-4940240-1_HP-4944-14-3945_CI-4940240-1
Fingerprint3945
SHA-25630193a06db2409ebef4c20d863143b33e3c9a1dd721936b2850c753cb92bb61d
First seen2026-11-25
Markets59 markets

Application program: FIX2 HM 12 T 1.4

Application number$4944
Version1.4
Mask versionMV-0701 (7.1)
KNX Data SecureNo
Parameters1175
Group objects259
Group objects (259)
NoNameFunctionSizeDPTFlags
0Channel H1Base setpoint value2 BytesCRW
0Channel H1Continuous actuating value1 ByteCRWU
0Channel H1Switching actuating value1 BitCRWU
1Channel H1Manual set point offset2 BytesCRW
2Channel H1Block valve protection1 BitCRW
2Channel H1Actual value2 BytesCRWU
3Channel H1Operating mode preset1 ByteCRW
3Channel H1Current actuating value1 ByteCRTU
4Channel H1Presence1 BitCRW
5Channel H1Window position1 BitCRW
6Channel H1Current operating mode1 ByteCRT
7Channel H1Heat & cool actuating values1 ByteCRT
7Channel H1Heating actuating value1 ByteCRT
8Channel H1Cooling actuating value1 ByteCRT
9Channel H1Heating = 1, Cooling = 01 BitDPT.1CRW
9Channel H1Heating = 0, Cooling = 11 Bit1.1 switchCRW
9Channel H1Forced operation mode1 BitCRWU
10Channel H1Current setpoint value2 BytesCRWT
11Channel H1Report actual value failure1 BitCRTU
11Channel H1Report actuating value failure1 BitCRTU
12Channel H2Continuous actuating value1 ByteCRWU
12Channel H2Switching actuating value1 BitCRWU
12Channel H2Base setpoint value2 BytesCRW
13Channel H2Manual set point offset2 BytesCRW
14Channel H2Block valve protection1 BitCRW
14Channel H2Actual value2 BytesCRWU
15Channel H2Current actuating value1 ByteCRTU
15Channel H2Operating mode preset1 ByteCRW
16Channel H2Presence1 BitCRW
17Channel H2Window position1 BitCRW
18Channel H2Current operating mode1 ByteCRT
19Channel H2Heat & cool actuating values1 ByteCRT
19Channel H2Heating actuating value1 ByteCRT
20Channel H2Cooling actuating value1 ByteCRT
21Channel H2Heating = 1, Cooling = 01 BitDPT.1CRW
21Channel H2Heating = 0, Cooling = 11 Bit1.1 switchCRW
21Channel H2Forced operation mode1 BitCRWU
22Channel H2Current setpoint value2 BytesCRWT
23Channel H2Report actuating value failure1 BitCRTU
23Channel H2Report actual value failure1 BitCRTU
24Channel H3Continuous actuating value1 ByteCRWU
24Channel H3Switching actuating value1 BitCRWU
24Channel H3Base setpoint value2 BytesCRW
25Channel H3Manual set point offset2 BytesCRW
26Channel H3Block valve protection1 BitCRW
26Channel H3Actual value2 BytesCRWU
27Channel H3Current actuating value1 ByteCRTU
27Channel H3Operating mode preset1 ByteCRW
28Channel H3Presence1 BitCRW
29Channel H3Window position1 BitCRW
30Channel H3Current operating mode1 ByteCRT
31Channel H3Heat & cool actuating values1 ByteCRT
31Channel H3Heating actuating value1 ByteCRT
32Channel H3Cooling actuating value1 ByteCRT
33Channel H3Heating = 1, Cooling = 01 BitDPT.1CRW
33Channel H3Heating = 0, Cooling = 11 Bit1.1 switchCRW
33Channel H3Forced operation mode1 BitCRWU
34Channel H3Current setpoint value2 BytesCRWT
35Channel H3Report actuating value failure1 BitCRTU
35Channel H3Report actual value failure1 BitCRTU
36Channel H4Continuous actuating value1 ByteCRWU
36Channel H4Switching actuating value1 BitCRWU
36Channel H4Base setpoint value2 BytesCRW
37Channel H4Manual set point offset2 BytesCRW
38Channel H4Block valve protection1 BitCRW
38Channel H4Actual value2 BytesCRWU
39Channel H4Current actuating value1 ByteCRTU
39Channel H4Operating mode preset1 ByteCRW
40Channel H4Presence1 BitCRW
41Channel H4Window position1 BitCRW
42Channel H4Current operating mode1 ByteCRT
43Channel H4Heat & cool actuating values1 ByteCRT
43Channel H4Heating actuating value1 ByteCRT
44Channel H4Cooling actuating value1 ByteCRT
45Channel H4Heating = 1, Cooling = 01 BitDPT.1CRW
45Channel H4Heating = 0, Cooling = 11 Bit1.1 switchCRW
45Channel H4Forced operation mode1 BitCRWU
46Channel H4Current setpoint value2 BytesCRWT
47Channel H4Report actuating value failure1 BitCRTU
47Channel H4Report actual value failure1 BitCRTU
48Channel H5Continuous actuating value1 ByteCRWU
48Channel H5Switching actuating value1 BitCRWU
48Channel H5Base setpoint value2 BytesCRW
49Channel H5Manual set point offset2 BytesCRW
50Channel H5Block valve protection1 BitCRW
50Channel H5Actual value2 BytesCRWU
51Channel H5Current actuating value1 ByteCRTU
51Channel H5Operating mode preset1 ByteCRW
52Channel H5Presence1 BitCRW
53Channel H5Window position1 BitCRW
54Channel H5Current operating mode1 ByteCRT
55Channel H5Heating actuating value1 ByteCRT
55Channel H5Heat & cool actuating values1 ByteCRT
56Channel H5Cooling actuating value1 ByteCRT
57Channel H5Heating = 1, Cooling = 01 BitDPT.1CRW
57Channel H5Heating = 0, Cooling = 11 Bit1.1 switchCRW
57Channel H5Forced operation mode1 BitCRWU
58Channel H5Current setpoint value2 BytesCRWT
59Channel H5Report actuating value failure1 BitCRTU
59Channel H5Report actual value failure1 BitCRTU
60Channel H6Continuous actuating value1 ByteCRWU
60Channel H6Switching actuating value1 BitCRWU
60Channel H6Base setpoint value2 BytesCRW
61Channel H6Manual set point offset2 BytesCRW
62Channel H6Block valve protection1 BitCRW
62Channel H6Actual value2 BytesCRWU
63Channel H6Current actuating value1 ByteCRTU
63Channel H6Operating mode preset1 ByteCRW
64Channel H6Presence1 BitCRW
65Channel H6Window position1 BitCRW
66Channel H6Current operating mode1 ByteCRT
67Channel H6Heat & cool actuating values1 ByteCRT
67Channel H6Heating actuating value1 ByteCRT
68Channel H6Cooling actuating value1 ByteCRT
69Channel H6Heating = 1, Cooling = 01 BitDPT.1CRW
69Channel H6Heating = 0, Cooling = 11 Bit1.1 switchCRW
69Channel H6Forced operation mode1 BitCRWU
70Channel H6Current setpoint value2 BytesCRWT
71Channel H6Report actuating value failure1 BitCRTU
71Channel H6Report actual value failure1 BitCRTU
72H1 - H6Summer mode ON/OFF1 BitCRWU
73H1 - H3Overcurr./short circuit1 BitCRTU
74H4 - H6Overcurr./short circuit1 BitCRTU
75H1 - H6Highest actuating value1 ByteCRTU
76H1 - H6Pump ON/OFF1 BitCRTU
77H1 - H6Outside temperature2 BytesCRWU
78H1 - H6Manual1 BitCRWTU
79H1 - H6Outside temperature failure1 BitCRTU
80Channel H7Continuous actuating value1 ByteCRWU
80Channel H7Switching actuating value1 BitCRWU
80Channel H7Base setpoint value2 BytesCRW
81Channel H7Manual set point offset2 BytesCRW
82Channel H7Block valve protection1 BitCRW
82Channel H7Actual value2 BytesCRWU
83Channel H7Current actuating value1 ByteCRTU
83Channel H7Operating mode preset1 ByteCRW
84Channel H7Presence1 BitCRW
85Channel H7Window position1 BitCRW
86Channel H7Current operating mode1 ByteCRT
87Channel H7Heating actuating value1 ByteCRT
87Channel H7Heat & cool actuating values1 ByteCRT
88Channel H7Cooling actuating value1 ByteCRT
89Channel H7Heating = 1, Cooling = 01 BitDPT.1CRW
89Channel H7Heating = 0, Cooling = 11 Bit1.1 switchCRW
89Channel H7Forced operation mode1 BitCRWU
90Channel H7Current setpoint value2 BytesCRWT
91Channel H7Report actuating value failure1 BitCRTU
91Channel H7Report actual value failure1 BitCRTU
92Channel H8Continuous actuating value1 ByteCRWU
92Channel H8Switching actuating value1 BitCRWU
92Channel H8Base setpoint value2 BytesCRW
93Channel H8Manual set point offset2 BytesCRW
94Channel H8Block valve protection1 BitCRW
94Channel H8Actual value2 BytesCRWU
95Channel H8Current actuating value1 ByteCRTU
95Channel H8Operating mode preset1 ByteCRW
96Channel H8Presence1 BitCRW
97Channel H8Window position1 BitCRW
98Channel H8Current operating mode1 ByteCRT
99Channel H8Heat & cool actuating values1 ByteCRT
99Channel H8Heating actuating value1 ByteCRT
100Channel H8Cooling actuating value1 ByteCRT
101Channel H8Heating = 1, Cooling = 01 BitDPT.1CRW
101Channel H8Heating = 0, Cooling = 11 Bit1.1 switchCRW
101Channel H8Forced operation mode1 BitCRWU
102Channel H8Current setpoint value2 BytesCRWT
103Channel H8Report actuating value failure1 BitCRTU
103Channel H8Report actual value failure1 BitCRTU
104Channel H9Continuous actuating value1 ByteCRWU
104Channel H9Switching actuating value1 BitCRWU
104Channel H9Base setpoint value2 BytesCRW
105Channel H9Manual set point offset2 BytesCRW
106Channel H9Block valve protection1 BitCRW
106Channel H9Actual value2 BytesCRWU
107Channel H9Current actuating value1 ByteCRTU
107Channel H9Operating mode preset1 ByteCRW
108Channel H9Presence1 BitCRW
109Channel H9Window position1 BitCRW
110Channel H9Current operating mode1 ByteCRT
111Channel H9Heat & cool actuating values1 ByteCRT
111Channel H9Heating actuating value1 ByteCRT
112Channel H9Cooling actuating value1 ByteCRT
113Channel H9Heating = 1, Cooling = 01 BitDPT.1CRW
113Channel H9Heating = 0, Cooling = 11 Bit1.1 switchCRW
113Channel H9Forced operation mode1 BitCRWU
114Channel H9Current setpoint value2 BytesCRWT
115Channel H9Report actuating value failure1 BitCRTU
115Channel H9Report actual value failure1 BitCRTU
116Channel H10Continuous actuating value1 ByteCRWU
116Channel H10Switching actuating value1 BitCRWU
116Channel H10Base setpoint value2 BytesCRW
117Channel H10Manual set point offset2 BytesCRW
118Channel H10Block valve protection1 BitCRW
118Channel H10Actual value2 BytesCRWU
119Channel H10Current actuating value1 ByteCRTU
119Channel H10Operating mode preset1 ByteCRW
120Channel H10Presence1 BitCRW
121Channel H10Window position1 BitCRW
122Channel H10Current operating mode1 ByteCRT
123Channel H10Heating actuating value1 ByteCRT
123Channel H10Heat & cool actuating values1 ByteCRT
124Channel H10Cooling actuating value1 ByteCRT
125Channel H10Heating = 1, Cooling = 01 BitDPT.1CRW
125Channel H10Heating = 0, Cooling = 11 Bit1.1 switchCRW
125Channel H10Forced operation mode1 BitCRWU
126Channel H10Current setpoint value2 BytesCRWT
127Channel H10Report actuating value failure1 BitCRTU
127Channel H10Report actual value failure1 BitCRTU
128Channel H11Continuous actuating value1 ByteCRWU
128Channel H11Switching actuating value1 BitCRWU
128Channel H11Base setpoint value2 BytesCRW
129Channel H11Manual set point offset2 BytesCRW
130Channel H11Block valve protection1 BitCRW
130Channel H11Actual value2 BytesCRWU
131Channel H11Current actuating value1 ByteCRTU
131Channel H11Operating mode preset1 ByteCRW
132Channel H11Presence1 BitCRW
133Channel H11Window position1 BitCRW
134Channel H11Current operating mode1 ByteCRT
135Channel H11Heating actuating value1 ByteCRT
135Channel H11Heat & cool actuating values1 ByteCRT
136Channel H11Cooling actuating value1 ByteCRT
137Channel H11Heating = 1, Cooling = 01 BitDPT.1CRW
137Channel H11Heating = 0, Cooling = 11 Bit1.1 switchCRW
137Channel H11Forced operation mode1 BitCRWU
138Channel H11Current setpoint value2 BytesCRWT
139Channel H11Report actuating value failure1 BitCRTU
139Channel H11Report actual value failure1 BitCRTU
140Channel H12Continuous actuating value1 ByteCRWU
140Channel H12Switching actuating value1 BitCRWU
140Channel H12Base setpoint value2 BytesCRW
141Channel H12Manual set point offset2 BytesCRW
142Channel H12Block valve protection1 BitCRW
142Channel H12Actual value2 BytesCRWU
143Channel H12Current actuating value1 ByteCRTU
143Channel H12Operating mode preset1 ByteCRW
144Channel H12Presence1 BitCRW
145Channel H12Window position1 BitCRW
146Channel H12Current operating mode1 ByteCRT
147Channel H12Heat & cool actuating values1 ByteCRT
147Channel H12Heating actuating value1 ByteCRT
148Channel H12Cooling actuating value1 ByteCRT
149Channel H12Heating = 1, Cooling = 01 BitDPT.1CRW
149Channel H12Heating = 0, Cooling = 11 Bit1.1 switchCRW
149Channel H12Forced operation mode1 BitCRWU
150Channel H12Current setpoint value2 BytesCRWT
151Channel H12Report actuating value failure1 BitCRTU
151Channel H12Report actual value failure1 BitCRTU
152H7 - H12Summer mode ON/OFF1 BitCRWU
153H7 - H9Overcurr./short circuit1 BitCRTU
154H10 - H12Overcurr./short circuit1 BitCRTU
155H7 - H12Highest actuating value1 ByteCRTU
156H7 - H12Pump ON/OFF1 BitCRTU
157H7 - H12Outside temperature2 BytesCRWU
158H7 - H12Manual1 BitCRWTU
159H7 - H12Outside temperature failure1 BitCRTU
250BCU versionTransmit14 BytesCRTU
251Version Channel H1 - H6Transmit14 BytesCRTU
252Version Channel H7 - H12Transmit14 BytesCRTU
Parameters (107)
ParameterTypeDefault
Anzahl Allg. ParameterunsignedInt 1…33
Download erfolgt 101listyes
-listLink HMG 6 T
Type of basic modulelistHMG 6 T..
Type of basic modulelistHMG 6 T
TypelistHM 6 T..
Zeit für zykl. Senden der Rückmeldeobj. (MIX 1 Serie, Best. Nr.491...)list15 min
Function of manual push buttonlistvalid until reset via object
Manual operation of channelslistenabled
Channel functionlistHeating actuator
Type of actuating valuelistContinuous..
Include in summer modelistno
Activate valve protectionlistyes
Valve protection disable telegramlist1 = Block (standard)
Execute valve protectionlistAlways
Monitor actual valuelistno
Monitoring actuating valuelistno
Activate compulsory functionlistno
Controlliststandard
Control functions usedlistOnly heating control
Setting the control parameterslistVia installation type
Proportional band of heating controllist2 K
System typelistRadiator heating system
Integrated time of heating controllist10 h
Send heating actuating value in cycleslistWith change of 5 %
Send heating actuating value in cycleslistNot cyclical, only in the event of change
Base setpoint value after loading the applicationlist21 °C
Reduction in standby mode (during heating)list1,5 K
Reduction in night mode (during heating)list5 K
Setpoint value for frost protection operation (during heating)list5 °C
Setpoint offset applieslistIn comfort, standby and night mode
Current setpoint value in comfort modelistSends actual value (heating < > cooling)
Send current setpoint value in cycleslistNot cyclical, only in the event of change
Maximum valid setpoint offsetlist+/-5 K
Minimum valid base setpoint valuelist10 °C
Maximum valid base setpoint valuelist32 °C
Proportional band of the cooling controllist4 K
System typelistCooling surface
Integrated time of the cooling controllist180 min.
Send cooling actuating valuelistWith change of 5 %
Sends the cooling actuating value in cycleslistNot cyclical, only in the event of change
Switchover between heating and coolinglistautomatic
Format object heating/coolinglistDPT100 (Heating= 1 / Cooling=0)
Output of the cooling actuating valuelistOn separate object
Dead zone between heating and coolinglist2 K
Increase in standby mode (during cooling)list1,5 K
Increase in night mode (during cooling)list5 K
Setpoint value for heat protection mode (during cooling)list42 °C i.e. no real heat protection
Operating mode after resetlistStandby
Type of presence sensorlistPresence detector
Comfort extension by presence buttons in night modelist2 hours
Sends the current operating mode in cycleslistNot cyclical, only in the event of change
Channel processes actuating value forlistHeating
PWM Einheit - SPÄTER UNSICHTBAR -listMinutes
Actuation cycle time (PWM period)list10 min
Actuation cycle time (PWM period) for emergency program and forced operationlist10 min
Actuator direction of operationlistStandard: 1 = Open valve (Theben actuator)
Minimum actuating valuelist0 %
Maximum actuating valuelist90 %
Actuating value when value violates the min./max. actuating valuelist0 = 0%, otherwise use set actuating values
Send current actuating valuelistWith change of 5 %
Send current actuating value in cycleslistNot cyclical, only in the event of change
Take channel H1 into account for highest actuating valuelistyes
Take channel H1 into account for pump controllistyes
Actuating value for emergency program islistAmbient temperature dependent
Fixed emergency program in winter modelist20 %
Emergency program active when outside temperature belowlist10 °C
Max. actuating value in emergency programlist40 %
Fixed emergency program with failure of outside temperaturelist20 %
Actuating value in the forced operation modelist0 %
Forced telegramlist1 = Force (standard)
Take channel H2 into account for highest actuating valuelistyes
Take channel H2 into account for pump controllistyes
Take channel H3 into account for highest actuating valuelistyes
Take channel H3 into account for pump controllistyes
Take channel H4 into account for highest actuating valuelistyes
Take channel H4 into account for pump controllistyes
-listWith change of 5 %
-list100 %
Maximum actuating valuelist100 %
-listno
Take channel H5 into account for highest actuating valuelistno
Take channel H5 into account for pump controllistyes
Take channel H6 into account for highest actuating valuelistno
Take channel H6 into account for pump controllistyes
Monitoring timelist30 min.
Status of monitoringlistReport only in the event of malfunction
Send status in cycleslistno
Cycle timelistEvery 30 min.
Switch pump ON only when at least (only for devices from 10.2016)listone input actuating value is > 0 %
Switch-off delay for pumplist10 min
Send pump control in cycleslistno, only in the event of change
Send highest actuating value in cycles (If continuous actuating value used)listno, only in the event of change
-listLink 1. HME 6 T
Take channel H7 into account for highest actuating valuelistyes
Take channel H7 into account for pump controllistyes
Take channel H8 into account for highest actuating valuelistyes
Take channel H8 into account for pump controllistyes
Take channel H9 into account for highest actuating valuelistyes
Take channel H9 into account for pump controllistyes
Take channel H10 into account for highest actuating valuelistyes
Take channel H10 into account for pump controllistyes
Take channel H11 into account for highest actuating valuelistno
Take channel H11 into account for pump controllistyes
PWM Einheit - UNSICHTBAR -listMinutes
Take channel H12 into account for highest actuating valuelistno
Take channel H12 into account for pump controllistyes

Version history

ApplicationApp noFingerprintFirst seenSizeFile
FIX2 HM 12 T 1.4 latest$494439452026-11-25240 KBDownload

About this file

This is the official ETS product database for the Theben AG HM 6 T (4940240), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Theben AG

All Theben AG products