HM 6 T 4940240
Theben AG · Order number 4940240 · Heizungsaktoren › HM 6 T
6-way heating actuator FIX1
Download .knxprod FIX2 HM 12 T 1.4 · 240 KB
Product
| Manufacturer | Theben AG |
|---|---|
| Product name | HM 6 T |
| Order number | 4940240 |
| Product text | HM 6 T (6-way heating actuator) |
| Hardware | FIX1-SERIES HM 6 T |
| Medium | Twisted Pair |
| Bus current (mA) | 5 |
| Rail mounted | Yes |
| Width (mm) | 72 |
| Registration | Certified · 2018-04-20 |
| Languages | de-DE, en-US, es-ES, fr-FR, it-IT, nl-NL |
| Catalog entry | M-0048_H-4940240-1_HP-4944-14-3945_CI-4940240-1 |
| Fingerprint | 3945 |
| SHA-256 | 30193a06db2409ebef4c20d863143b33e3c9a1dd721936b2850c753cb92bb61d |
| First seen | 2026-11-25 |
| Markets | 59 markets |
Application program: FIX2 HM 12 T 1.4
| Application number | $4944 |
|---|---|
| Version | 1.4 |
| Mask version | MV-0701 (7.1) |
| KNX Data Secure | No |
| Parameters | 1175 |
| Group objects | 259 |
Group objects (259)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Channel H1 | Base setpoint value | 2 Bytes | CRW | |
| 0 | Channel H1 | Continuous actuating value | 1 Byte | CRWU | |
| 0 | Channel H1 | Switching actuating value | 1 Bit | CRWU | |
| 1 | Channel H1 | Manual set point offset | 2 Bytes | CRW | |
| 2 | Channel H1 | Block valve protection | 1 Bit | CRW | |
| 2 | Channel H1 | Actual value | 2 Bytes | CRWU | |
| 3 | Channel H1 | Operating mode preset | 1 Byte | CRW | |
| 3 | Channel H1 | Current actuating value | 1 Byte | CRTU | |
| 4 | Channel H1 | Presence | 1 Bit | CRW | |
| 5 | Channel H1 | Window position | 1 Bit | CRW | |
| 6 | Channel H1 | Current operating mode | 1 Byte | CRT | |
| 7 | Channel H1 | Heat & cool actuating values | 1 Byte | CRT | |
| 7 | Channel H1 | Heating actuating value | 1 Byte | CRT | |
| 8 | Channel H1 | Cooling actuating value | 1 Byte | CRT | |
| 9 | Channel H1 | Heating = 1, Cooling = 0 | 1 Bit | DPT.1 | CRW |
| 9 | Channel H1 | Heating = 0, Cooling = 1 | 1 Bit | 1.1 switch | CRW |
| 9 | Channel H1 | Forced operation mode | 1 Bit | CRWU | |
| 10 | Channel H1 | Current setpoint value | 2 Bytes | CRWT | |
| 11 | Channel H1 | Report actual value failure | 1 Bit | CRTU | |
| 11 | Channel H1 | Report actuating value failure | 1 Bit | CRTU | |
| 12 | Channel H2 | Continuous actuating value | 1 Byte | CRWU | |
| 12 | Channel H2 | Switching actuating value | 1 Bit | CRWU | |
| 12 | Channel H2 | Base setpoint value | 2 Bytes | CRW | |
| 13 | Channel H2 | Manual set point offset | 2 Bytes | CRW | |
| 14 | Channel H2 | Block valve protection | 1 Bit | CRW | |
| 14 | Channel H2 | Actual value | 2 Bytes | CRWU | |
| 15 | Channel H2 | Current actuating value | 1 Byte | CRTU | |
| 15 | Channel H2 | Operating mode preset | 1 Byte | CRW | |
| 16 | Channel H2 | Presence | 1 Bit | CRW | |
| 17 | Channel H2 | Window position | 1 Bit | CRW | |
| 18 | Channel H2 | Current operating mode | 1 Byte | CRT | |
| 19 | Channel H2 | Heat & cool actuating values | 1 Byte | CRT | |
| 19 | Channel H2 | Heating actuating value | 1 Byte | CRT | |
| 20 | Channel H2 | Cooling actuating value | 1 Byte | CRT | |
| 21 | Channel H2 | Heating = 1, Cooling = 0 | 1 Bit | DPT.1 | CRW |
| 21 | Channel H2 | Heating = 0, Cooling = 1 | 1 Bit | 1.1 switch | CRW |
| 21 | Channel H2 | Forced operation mode | 1 Bit | CRWU | |
| 22 | Channel H2 | Current setpoint value | 2 Bytes | CRWT | |
| 23 | Channel H2 | Report actuating value failure | 1 Bit | CRTU | |
| 23 | Channel H2 | Report actual value failure | 1 Bit | CRTU | |
| 24 | Channel H3 | Continuous actuating value | 1 Byte | CRWU | |
| 24 | Channel H3 | Switching actuating value | 1 Bit | CRWU | |
| 24 | Channel H3 | Base setpoint value | 2 Bytes | CRW | |
| 25 | Channel H3 | Manual set point offset | 2 Bytes | CRW | |
| 26 | Channel H3 | Block valve protection | 1 Bit | CRW | |
| 26 | Channel H3 | Actual value | 2 Bytes | CRWU | |
| 27 | Channel H3 | Current actuating value | 1 Byte | CRTU | |
| 27 | Channel H3 | Operating mode preset | 1 Byte | CRW | |
| 28 | Channel H3 | Presence | 1 Bit | CRW | |
| 29 | Channel H3 | Window position | 1 Bit | CRW | |
| 30 | Channel H3 | Current operating mode | 1 Byte | CRT | |
| 31 | Channel H3 | Heat & cool actuating values | 1 Byte | CRT | |
| 31 | Channel H3 | Heating actuating value | 1 Byte | CRT | |
| 32 | Channel H3 | Cooling actuating value | 1 Byte | CRT | |
| 33 | Channel H3 | Heating = 1, Cooling = 0 | 1 Bit | DPT.1 | CRW |
| 33 | Channel H3 | Heating = 0, Cooling = 1 | 1 Bit | 1.1 switch | CRW |
| 33 | Channel H3 | Forced operation mode | 1 Bit | CRWU | |
| 34 | Channel H3 | Current setpoint value | 2 Bytes | CRWT | |
| 35 | Channel H3 | Report actuating value failure | 1 Bit | CRTU | |
| 35 | Channel H3 | Report actual value failure | 1 Bit | CRTU | |
| 36 | Channel H4 | Continuous actuating value | 1 Byte | CRWU | |
| 36 | Channel H4 | Switching actuating value | 1 Bit | CRWU | |
| 36 | Channel H4 | Base setpoint value | 2 Bytes | CRW | |
| 37 | Channel H4 | Manual set point offset | 2 Bytes | CRW | |
| 38 | Channel H4 | Block valve protection | 1 Bit | CRW | |
| 38 | Channel H4 | Actual value | 2 Bytes | CRWU | |
| 39 | Channel H4 | Current actuating value | 1 Byte | CRTU | |
| 39 | Channel H4 | Operating mode preset | 1 Byte | CRW | |
| 40 | Channel H4 | Presence | 1 Bit | CRW | |
| 41 | Channel H4 | Window position | 1 Bit | CRW | |
| 42 | Channel H4 | Current operating mode | 1 Byte | CRT | |
| 43 | Channel H4 | Heat & cool actuating values | 1 Byte | CRT | |
| 43 | Channel H4 | Heating actuating value | 1 Byte | CRT | |
| 44 | Channel H4 | Cooling actuating value | 1 Byte | CRT | |
| 45 | Channel H4 | Heating = 1, Cooling = 0 | 1 Bit | DPT.1 | CRW |
| 45 | Channel H4 | Heating = 0, Cooling = 1 | 1 Bit | 1.1 switch | CRW |
| 45 | Channel H4 | Forced operation mode | 1 Bit | CRWU | |
| 46 | Channel H4 | Current setpoint value | 2 Bytes | CRWT | |
| 47 | Channel H4 | Report actuating value failure | 1 Bit | CRTU | |
| 47 | Channel H4 | Report actual value failure | 1 Bit | CRTU | |
| 48 | Channel H5 | Continuous actuating value | 1 Byte | CRWU | |
| 48 | Channel H5 | Switching actuating value | 1 Bit | CRWU | |
| 48 | Channel H5 | Base setpoint value | 2 Bytes | CRW | |
| 49 | Channel H5 | Manual set point offset | 2 Bytes | CRW | |
| 50 | Channel H5 | Block valve protection | 1 Bit | CRW | |
| 50 | Channel H5 | Actual value | 2 Bytes | CRWU | |
| 51 | Channel H5 | Current actuating value | 1 Byte | CRTU | |
| 51 | Channel H5 | Operating mode preset | 1 Byte | CRW | |
| 52 | Channel H5 | Presence | 1 Bit | CRW | |
| 53 | Channel H5 | Window position | 1 Bit | CRW | |
| 54 | Channel H5 | Current operating mode | 1 Byte | CRT | |
| 55 | Channel H5 | Heating actuating value | 1 Byte | CRT | |
| 55 | Channel H5 | Heat & cool actuating values | 1 Byte | CRT | |
| 56 | Channel H5 | Cooling actuating value | 1 Byte | CRT | |
| 57 | Channel H5 | Heating = 1, Cooling = 0 | 1 Bit | DPT.1 | CRW |
| 57 | Channel H5 | Heating = 0, Cooling = 1 | 1 Bit | 1.1 switch | CRW |
| 57 | Channel H5 | Forced operation mode | 1 Bit | CRWU | |
| 58 | Channel H5 | Current setpoint value | 2 Bytes | CRWT | |
| 59 | Channel H5 | Report actuating value failure | 1 Bit | CRTU | |
| 59 | Channel H5 | Report actual value failure | 1 Bit | CRTU | |
| 60 | Channel H6 | Continuous actuating value | 1 Byte | CRWU | |
| 60 | Channel H6 | Switching actuating value | 1 Bit | CRWU | |
| 60 | Channel H6 | Base setpoint value | 2 Bytes | CRW | |
| 61 | Channel H6 | Manual set point offset | 2 Bytes | CRW | |
| 62 | Channel H6 | Block valve protection | 1 Bit | CRW | |
| 62 | Channel H6 | Actual value | 2 Bytes | CRWU | |
| 63 | Channel H6 | Current actuating value | 1 Byte | CRTU | |
| 63 | Channel H6 | Operating mode preset | 1 Byte | CRW | |
| 64 | Channel H6 | Presence | 1 Bit | CRW | |
| 65 | Channel H6 | Window position | 1 Bit | CRW | |
| 66 | Channel H6 | Current operating mode | 1 Byte | CRT | |
| 67 | Channel H6 | Heat & cool actuating values | 1 Byte | CRT | |
| 67 | Channel H6 | Heating actuating value | 1 Byte | CRT | |
| 68 | Channel H6 | Cooling actuating value | 1 Byte | CRT | |
| 69 | Channel H6 | Heating = 1, Cooling = 0 | 1 Bit | DPT.1 | CRW |
| 69 | Channel H6 | Heating = 0, Cooling = 1 | 1 Bit | 1.1 switch | CRW |
| 69 | Channel H6 | Forced operation mode | 1 Bit | CRWU | |
| 70 | Channel H6 | Current setpoint value | 2 Bytes | CRWT | |
| 71 | Channel H6 | Report actuating value failure | 1 Bit | CRTU | |
| 71 | Channel H6 | Report actual value failure | 1 Bit | CRTU | |
| 72 | H1 - H6 | Summer mode ON/OFF | 1 Bit | CRWU | |
| 73 | H1 - H3 | Overcurr./short circuit | 1 Bit | CRTU | |
| 74 | H4 - H6 | Overcurr./short circuit | 1 Bit | CRTU | |
| 75 | H1 - H6 | Highest actuating value | 1 Byte | CRTU | |
| 76 | H1 - H6 | Pump ON/OFF | 1 Bit | CRTU | |
| 77 | H1 - H6 | Outside temperature | 2 Bytes | CRWU | |
| 78 | H1 - H6 | Manual | 1 Bit | CRWTU | |
| 79 | H1 - H6 | Outside temperature failure | 1 Bit | CRTU | |
| 80 | Channel H7 | Continuous actuating value | 1 Byte | CRWU | |
| 80 | Channel H7 | Switching actuating value | 1 Bit | CRWU | |
| 80 | Channel H7 | Base setpoint value | 2 Bytes | CRW | |
| 81 | Channel H7 | Manual set point offset | 2 Bytes | CRW | |
| 82 | Channel H7 | Block valve protection | 1 Bit | CRW | |
| 82 | Channel H7 | Actual value | 2 Bytes | CRWU | |
| 83 | Channel H7 | Current actuating value | 1 Byte | CRTU | |
| 83 | Channel H7 | Operating mode preset | 1 Byte | CRW | |
| 84 | Channel H7 | Presence | 1 Bit | CRW | |
| 85 | Channel H7 | Window position | 1 Bit | CRW | |
| 86 | Channel H7 | Current operating mode | 1 Byte | CRT | |
| 87 | Channel H7 | Heating actuating value | 1 Byte | CRT | |
| 87 | Channel H7 | Heat & cool actuating values | 1 Byte | CRT | |
| 88 | Channel H7 | Cooling actuating value | 1 Byte | CRT | |
| 89 | Channel H7 | Heating = 1, Cooling = 0 | 1 Bit | DPT.1 | CRW |
| 89 | Channel H7 | Heating = 0, Cooling = 1 | 1 Bit | 1.1 switch | CRW |
| 89 | Channel H7 | Forced operation mode | 1 Bit | CRWU | |
| 90 | Channel H7 | Current setpoint value | 2 Bytes | CRWT | |
| 91 | Channel H7 | Report actuating value failure | 1 Bit | CRTU | |
| 91 | Channel H7 | Report actual value failure | 1 Bit | CRTU | |
| 92 | Channel H8 | Continuous actuating value | 1 Byte | CRWU | |
| 92 | Channel H8 | Switching actuating value | 1 Bit | CRWU | |
| 92 | Channel H8 | Base setpoint value | 2 Bytes | CRW | |
| 93 | Channel H8 | Manual set point offset | 2 Bytes | CRW | |
| 94 | Channel H8 | Block valve protection | 1 Bit | CRW | |
| 94 | Channel H8 | Actual value | 2 Bytes | CRWU | |
| 95 | Channel H8 | Current actuating value | 1 Byte | CRTU | |
| 95 | Channel H8 | Operating mode preset | 1 Byte | CRW | |
| 96 | Channel H8 | Presence | 1 Bit | CRW | |
| 97 | Channel H8 | Window position | 1 Bit | CRW | |
| 98 | Channel H8 | Current operating mode | 1 Byte | CRT | |
| 99 | Channel H8 | Heat & cool actuating values | 1 Byte | CRT | |
| 99 | Channel H8 | Heating actuating value | 1 Byte | CRT | |
| 100 | Channel H8 | Cooling actuating value | 1 Byte | CRT | |
| 101 | Channel H8 | Heating = 1, Cooling = 0 | 1 Bit | DPT.1 | CRW |
| 101 | Channel H8 | Heating = 0, Cooling = 1 | 1 Bit | 1.1 switch | CRW |
| 101 | Channel H8 | Forced operation mode | 1 Bit | CRWU | |
| 102 | Channel H8 | Current setpoint value | 2 Bytes | CRWT | |
| 103 | Channel H8 | Report actuating value failure | 1 Bit | CRTU | |
| 103 | Channel H8 | Report actual value failure | 1 Bit | CRTU | |
| 104 | Channel H9 | Continuous actuating value | 1 Byte | CRWU | |
| 104 | Channel H9 | Switching actuating value | 1 Bit | CRWU | |
| 104 | Channel H9 | Base setpoint value | 2 Bytes | CRW | |
| 105 | Channel H9 | Manual set point offset | 2 Bytes | CRW | |
| 106 | Channel H9 | Block valve protection | 1 Bit | CRW | |
| 106 | Channel H9 | Actual value | 2 Bytes | CRWU | |
| 107 | Channel H9 | Current actuating value | 1 Byte | CRTU | |
| 107 | Channel H9 | Operating mode preset | 1 Byte | CRW | |
| 108 | Channel H9 | Presence | 1 Bit | CRW | |
| 109 | Channel H9 | Window position | 1 Bit | CRW | |
| 110 | Channel H9 | Current operating mode | 1 Byte | CRT | |
| 111 | Channel H9 | Heat & cool actuating values | 1 Byte | CRT | |
| 111 | Channel H9 | Heating actuating value | 1 Byte | CRT | |
| 112 | Channel H9 | Cooling actuating value | 1 Byte | CRT | |
| 113 | Channel H9 | Heating = 1, Cooling = 0 | 1 Bit | DPT.1 | CRW |
| 113 | Channel H9 | Heating = 0, Cooling = 1 | 1 Bit | 1.1 switch | CRW |
| 113 | Channel H9 | Forced operation mode | 1 Bit | CRWU | |
| 114 | Channel H9 | Current setpoint value | 2 Bytes | CRWT | |
| 115 | Channel H9 | Report actuating value failure | 1 Bit | CRTU | |
| 115 | Channel H9 | Report actual value failure | 1 Bit | CRTU | |
| 116 | Channel H10 | Continuous actuating value | 1 Byte | CRWU | |
| 116 | Channel H10 | Switching actuating value | 1 Bit | CRWU | |
| 116 | Channel H10 | Base setpoint value | 2 Bytes | CRW | |
| 117 | Channel H10 | Manual set point offset | 2 Bytes | CRW | |
| 118 | Channel H10 | Block valve protection | 1 Bit | CRW | |
| 118 | Channel H10 | Actual value | 2 Bytes | CRWU | |
| 119 | Channel H10 | Current actuating value | 1 Byte | CRTU | |
| 119 | Channel H10 | Operating mode preset | 1 Byte | CRW | |
| 120 | Channel H10 | Presence | 1 Bit | CRW | |
| 121 | Channel H10 | Window position | 1 Bit | CRW | |
| 122 | Channel H10 | Current operating mode | 1 Byte | CRT | |
| 123 | Channel H10 | Heating actuating value | 1 Byte | CRT | |
| 123 | Channel H10 | Heat & cool actuating values | 1 Byte | CRT | |
| 124 | Channel H10 | Cooling actuating value | 1 Byte | CRT | |
| 125 | Channel H10 | Heating = 1, Cooling = 0 | 1 Bit | DPT.1 | CRW |
| 125 | Channel H10 | Heating = 0, Cooling = 1 | 1 Bit | 1.1 switch | CRW |
| 125 | Channel H10 | Forced operation mode | 1 Bit | CRWU | |
| 126 | Channel H10 | Current setpoint value | 2 Bytes | CRWT | |
| 127 | Channel H10 | Report actuating value failure | 1 Bit | CRTU | |
| 127 | Channel H10 | Report actual value failure | 1 Bit | CRTU | |
| 128 | Channel H11 | Continuous actuating value | 1 Byte | CRWU | |
| 128 | Channel H11 | Switching actuating value | 1 Bit | CRWU | |
| 128 | Channel H11 | Base setpoint value | 2 Bytes | CRW | |
| 129 | Channel H11 | Manual set point offset | 2 Bytes | CRW | |
| 130 | Channel H11 | Block valve protection | 1 Bit | CRW | |
| 130 | Channel H11 | Actual value | 2 Bytes | CRWU | |
| 131 | Channel H11 | Current actuating value | 1 Byte | CRTU | |
| 131 | Channel H11 | Operating mode preset | 1 Byte | CRW | |
| 132 | Channel H11 | Presence | 1 Bit | CRW | |
| 133 | Channel H11 | Window position | 1 Bit | CRW | |
| 134 | Channel H11 | Current operating mode | 1 Byte | CRT | |
| 135 | Channel H11 | Heating actuating value | 1 Byte | CRT | |
| 135 | Channel H11 | Heat & cool actuating values | 1 Byte | CRT | |
| 136 | Channel H11 | Cooling actuating value | 1 Byte | CRT | |
| 137 | Channel H11 | Heating = 1, Cooling = 0 | 1 Bit | DPT.1 | CRW |
| 137 | Channel H11 | Heating = 0, Cooling = 1 | 1 Bit | 1.1 switch | CRW |
| 137 | Channel H11 | Forced operation mode | 1 Bit | CRWU | |
| 138 | Channel H11 | Current setpoint value | 2 Bytes | CRWT | |
| 139 | Channel H11 | Report actuating value failure | 1 Bit | CRTU | |
| 139 | Channel H11 | Report actual value failure | 1 Bit | CRTU | |
| 140 | Channel H12 | Continuous actuating value | 1 Byte | CRWU | |
| 140 | Channel H12 | Switching actuating value | 1 Bit | CRWU | |
| 140 | Channel H12 | Base setpoint value | 2 Bytes | CRW | |
| 141 | Channel H12 | Manual set point offset | 2 Bytes | CRW | |
| 142 | Channel H12 | Block valve protection | 1 Bit | CRW | |
| 142 | Channel H12 | Actual value | 2 Bytes | CRWU | |
| 143 | Channel H12 | Current actuating value | 1 Byte | CRTU | |
| 143 | Channel H12 | Operating mode preset | 1 Byte | CRW | |
| 144 | Channel H12 | Presence | 1 Bit | CRW | |
| 145 | Channel H12 | Window position | 1 Bit | CRW | |
| 146 | Channel H12 | Current operating mode | 1 Byte | CRT | |
| 147 | Channel H12 | Heat & cool actuating values | 1 Byte | CRT | |
| 147 | Channel H12 | Heating actuating value | 1 Byte | CRT | |
| 148 | Channel H12 | Cooling actuating value | 1 Byte | CRT | |
| 149 | Channel H12 | Heating = 1, Cooling = 0 | 1 Bit | DPT.1 | CRW |
| 149 | Channel H12 | Heating = 0, Cooling = 1 | 1 Bit | 1.1 switch | CRW |
| 149 | Channel H12 | Forced operation mode | 1 Bit | CRWU | |
| 150 | Channel H12 | Current setpoint value | 2 Bytes | CRWT | |
| 151 | Channel H12 | Report actuating value failure | 1 Bit | CRTU | |
| 151 | Channel H12 | Report actual value failure | 1 Bit | CRTU | |
| 152 | H7 - H12 | Summer mode ON/OFF | 1 Bit | CRWU | |
| 153 | H7 - H9 | Overcurr./short circuit | 1 Bit | CRTU | |
| 154 | H10 - H12 | Overcurr./short circuit | 1 Bit | CRTU | |
| 155 | H7 - H12 | Highest actuating value | 1 Byte | CRTU | |
| 156 | H7 - H12 | Pump ON/OFF | 1 Bit | CRTU | |
| 157 | H7 - H12 | Outside temperature | 2 Bytes | CRWU | |
| 158 | H7 - H12 | Manual | 1 Bit | CRWTU | |
| 159 | H7 - H12 | Outside temperature failure | 1 Bit | CRTU | |
| 250 | BCU version | Transmit | 14 Bytes | CRTU | |
| 251 | Version Channel H1 - H6 | Transmit | 14 Bytes | CRTU | |
| 252 | Version Channel H7 - H12 | Transmit | 14 Bytes | CRTU |
Parameters (107)
| Parameter | Type | Default |
|---|---|---|
| Anzahl Allg. Parameter | unsignedInt 1…3 | 3 |
| Download erfolgt 101 | list | yes |
| - | list | Link HMG 6 T |
| Type of basic module | list | HMG 6 T.. |
| Type of basic module | list | HMG 6 T |
| Type | list | HM 6 T.. |
| Zeit für zykl. Senden der Rückmeldeobj. (MIX 1 Serie, Best. Nr.491...) | list | 15 min |
| Function of manual push button | list | valid until reset via object |
| Manual operation of channels | list | enabled |
| Channel function | list | Heating actuator |
| Type of actuating value | list | Continuous.. |
| Include in summer mode | list | no |
| Activate valve protection | list | yes |
| Valve protection disable telegram | list | 1 = Block (standard) |
| Execute valve protection | list | Always |
| Monitor actual value | list | no |
| Monitoring actuating value | list | no |
| Activate compulsory function | list | no |
| Control | list | standard |
| Control functions used | list | Only heating control |
| Setting the control parameters | list | Via installation type |
| Proportional band of heating control | list | 2 K |
| System type | list | Radiator heating system |
| Integrated time of heating control | list | 10 h |
| Send heating actuating value in cycles | list | With change of 5 % |
| Send heating actuating value in cycles | list | Not cyclical, only in the event of change |
| Base setpoint value after loading the application | list | 21 °C |
| Reduction in standby mode (during heating) | list | 1,5 K |
| Reduction in night mode (during heating) | list | 5 K |
| Setpoint value for frost protection operation (during heating) | list | 5 °C |
| Setpoint offset applies | list | In comfort, standby and night mode |
| Current setpoint value in comfort mode | list | Sends actual value (heating < > cooling) |
| Send current setpoint value in cycles | list | Not cyclical, only in the event of change |
| Maximum valid setpoint offset | list | +/-5 K |
| Minimum valid base setpoint value | list | 10 °C |
| Maximum valid base setpoint value | list | 32 °C |
| Proportional band of the cooling control | list | 4 K |
| System type | list | Cooling surface |
| Integrated time of the cooling control | list | 180 min. |
| Send cooling actuating value | list | With change of 5 % |
| Sends the cooling actuating value in cycles | list | Not cyclical, only in the event of change |
| Switchover between heating and cooling | list | automatic |
| Format object heating/cooling | list | DPT100 (Heating= 1 / Cooling=0) |
| Output of the cooling actuating value | list | On separate object |
| Dead zone between heating and cooling | list | 2 K |
| Increase in standby mode (during cooling) | list | 1,5 K |
| Increase in night mode (during cooling) | list | 5 K |
| Setpoint value for heat protection mode (during cooling) | list | 42 °C i.e. no real heat protection |
| Operating mode after reset | list | Standby |
| Type of presence sensor | list | Presence detector |
| Comfort extension by presence buttons in night mode | list | 2 hours |
| Sends the current operating mode in cycles | list | Not cyclical, only in the event of change |
| Channel processes actuating value for | list | Heating |
| PWM Einheit - SPÄTER UNSICHTBAR - | list | Minutes |
| Actuation cycle time (PWM period) | list | 10 min |
| Actuation cycle time (PWM period) for emergency program and forced operation | list | 10 min |
| Actuator direction of operation | list | Standard: 1 = Open valve (Theben actuator) |
| Minimum actuating value | list | 0 % |
| Maximum actuating value | list | 90 % |
| Actuating value when value violates the min./max. actuating value | list | 0 = 0%, otherwise use set actuating values |
| Send current actuating value | list | With change of 5 % |
| Send current actuating value in cycles | list | Not cyclical, only in the event of change |
| Take channel H1 into account for highest actuating value | list | yes |
| Take channel H1 into account for pump control | list | yes |
| Actuating value for emergency program is | list | Ambient temperature dependent |
| Fixed emergency program in winter mode | list | 20 % |
| Emergency program active when outside temperature below | list | 10 °C |
| Max. actuating value in emergency program | list | 40 % |
| Fixed emergency program with failure of outside temperature | list | 20 % |
| Actuating value in the forced operation mode | list | 0 % |
| Forced telegram | list | 1 = Force (standard) |
| Take channel H2 into account for highest actuating value | list | yes |
| Take channel H2 into account for pump control | list | yes |
| Take channel H3 into account for highest actuating value | list | yes |
| Take channel H3 into account for pump control | list | yes |
| Take channel H4 into account for highest actuating value | list | yes |
| Take channel H4 into account for pump control | list | yes |
| - | list | With change of 5 % |
| - | list | 100 % |
| Maximum actuating value | list | 100 % |
| - | list | no |
| Take channel H5 into account for highest actuating value | list | no |
| Take channel H5 into account for pump control | list | yes |
| Take channel H6 into account for highest actuating value | list | no |
| Take channel H6 into account for pump control | list | yes |
| Monitoring time | list | 30 min. |
| Status of monitoring | list | Report only in the event of malfunction |
| Send status in cycles | list | no |
| Cycle time | list | Every 30 min. |
| Switch pump ON only when at least (only for devices from 10.2016) | list | one input actuating value is > 0 % |
| Switch-off delay for pump | list | 10 min |
| Send pump control in cycles | list | no, only in the event of change |
| Send highest actuating value in cycles (If continuous actuating value used) | list | no, only in the event of change |
| - | list | Link 1. HME 6 T |
| Take channel H7 into account for highest actuating value | list | yes |
| Take channel H7 into account for pump control | list | yes |
| Take channel H8 into account for highest actuating value | list | yes |
| Take channel H8 into account for pump control | list | yes |
| Take channel H9 into account for highest actuating value | list | yes |
| Take channel H9 into account for pump control | list | yes |
| Take channel H10 into account for highest actuating value | list | yes |
| Take channel H10 into account for pump control | list | yes |
| Take channel H11 into account for highest actuating value | list | no |
| Take channel H11 into account for pump control | list | yes |
| PWM Einheit - UNSICHTBAR - | list | Minutes |
| Take channel H12 into account for highest actuating value | list | no |
| Take channel H12 into account for pump control | list | yes |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| FIX2 HM 12 T 1.4 latest | $4944 | 3945 | 2026-11-25 | 240 KB | Download |
About this file
This is the official ETS product database for the Theben AG HM 6 T (4940240), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.