SCN-RTRGx.02 Glass Room Temperature Controller Smart with Colour display SCN-RTRGx.02
MDT technologies GmbH · Order number SCN-RTRGx.02 · Temperature Controller › Glass Room temperature controller
Download .knxprod Glass Temperature Controller Smart 1.2 · 326 KB
Product
| Manufacturer | MDT technologies GmbH |
|---|---|
| Product name | SCN-RTRGx.02 Glass Room Temperature Controller Smart with Colour display |
| Order number | SCN-RTRGx.02 |
| Product text | SCN-RTRGx.02 Glass Room Temperature Controller Smart with colour display |
| Hardware | Glas Raumtemperaturregler Smart |
| Medium | Twisted Pair |
| Bus current (mA) | 10 |
| Rail mounted | No |
| Registration | Certified · 2022-04-19 |
| Languages | de-DE, en-US, es-ES, fr-FR |
| Catalog entry | M-0083_H-272-1_HP-0247-12-B13D_CI-SCN.2DRTRGx.2E02-1 |
| Fingerprint | B13D |
| SHA-256 | 3a49a4aec0c9084e045d89689f1f10f7774348bc7cbe7613fa8abe79191e3737 |
| First seen | 2026-11-25 |
| Markets | 69 markets |
Application program: Glass Temperature Controller Smart 1.2
| Application number | $0247 |
|---|---|
| Version | 1.2 |
| Mask version | MV-0705 (7.5) |
| KNX Data Secure | No |
| Minimum ETS version | 5.0 |
| Parameters | 538 |
| Group objects | 261 |
Group objects (261)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Setpoint setting | Preset setpoint | 2 Bytes | 9.1 temperature (°C) | CW |
| 0 | Setpoint setting | Preset setpoint | 2 Bytes | 9.1 temperature (°C) | CRT |
| 1 | Comfort | Preset setpoint | 2 Bytes | 9.1 temperature (°C) | CW |
| 1 | Combination object | Preset setpoint | 8 Bytes | 275.100 Temperature setpoint setting for 4 HVAC Modes | CW |
| 1 | (Basic) Comfort setpoint | Preset setpoint | 2 Bytes | 9.1 temperature (°C) | CW |
| 1 | Combination object (Heating) | Preset setpoint | 8 Bytes | 275.100 Temperature setpoint setting for 4 HVAC Modes | CW |
| 2 | Standby | Preset setpoint | 2 Bytes | 9.1 temperature (°C) | CW |
| 3 | Night | Preset setpoint | 2 Bytes | 9.1 temperature (°C) | CW |
| 4 | Frost protection | Preset setpoint | 2 Bytes | 9.1 temperature (°C) | CW |
| 4 | Heating protection | Preset setpoint | 2 Bytes | 9.1 temperature (°C) | CW |
| 5 | Combination object (Cooling) | Preset setpoint | 8 Bytes | 275.100 Temperature setpoint setting for 4 HVAC Modes | CW |
| 6 | Current setpoint | Receive setpoint | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 6 | Current setpoint | Send setpoint | 2 Bytes | 9.1 temperature (°C) | CRT |
| 7 | Manual setpoint shift | Increase / decrease (2Byte) | 2 Bytes | 9.2 temperature difference (K) | CW |
| 7 | Manual setpoint shift | Increase / decrease (1Byte) | 1 Byte | 6.10 counter pulses (-128..127) | CRT |
| 7 | Manual setpoint shift | Increase / decrease (2Byte) | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 8 | Manual setpoint shift | Increase / decrease (1=+ / 0=-) | 1 Bit | 1.7 step | CW |
| 8 | Manual setpoint shift | Increase / decrease (1Byte) | 1 Byte | 6.10 counter pulses (-128..127) | CW |
| 8 | Manual setpoint shift | Increase / decrease (1=+ / 0=-) | 1 Bit | 1.7 step | CT |
| 9 | Status setpoint shift | Send status | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 9 | Status setpoint shift | Receive status | 2 Bytes | 9.2 temperature difference (K) | CWTU |
| 10 | Control value Heating | Send control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 10 | Control value Heating | Send control value | 1 Bit | 1.1 switch | CRT |
| 10 | Control value Heating/Cooling | Send control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 10 | Control value Heating/Cooling | Send control value | 1 Bit | 1.1 switch | CRT |
| 11 | Control value Cooling | Send control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 11 | Control value Cooling | Send control value | 1 Bit | 1.1 switch | CRT |
| 12 | Control value Heating/Cooling | Receive status | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 12 | Control value Heating | Receive status | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 12 | Control value Heating | Send status | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 12 | Control value Heating/Cooling | Send status | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 13 | Control value Cooling | Receive status | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 13 | Control value Cooling | Send status | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 14 | Control value additional Heating | Send control value | 1 Bit | 1.1 switch | CT |
| 15 | Mode selection | Send mode | 1 Byte | 20.102 HVAC mode | CT |
| 15 | Mode selection | Select mode | 1 Byte | 20.102 HVAC mode | CW |
| 16 | Comfort mode | Comfort extension | 1 Bit | 1.10 start/stop | CW |
| 17 | Comfort mode | Switch mode | 1 Bit | 1.1 switch | CW |
| 18 | Night mode | Switch mode | 1 Bit | 1.1 switch | CW |
| 19 | Frost protection mode | Switch mode | 1 Bit | 1.1 switch | CW |
| 19 | Heat protection mode | Switch mode | 1 Bit | 1.1 switch | CW |
| 19 | Frost/Heat protection mode | Switch mode | 1 Bit | 1.1 switch | CW |
| 20 | DPT_HVAC Status | Receive controller status | 1 Byte | CWTU | |
| 20 | DPT_HVAC Mode | Receive controller status | 1 Byte | 20.102 HVAC mode | CWTU |
| 20 | DPT_HVAC Status | Send controller status | 1 Byte | CRT | |
| 20 | DPT_HVAC Mode | Send controller status | 1 Byte | 20.102 HVAC mode | CRT |
| 21 | DPT_HVAC Status | Send controller status | 1 Byte | CRT | |
| 21 | DPT_HVAC Mode | Send controller status | 1 Byte | 20.102 HVAC mode | CRT |
| 21 | RHCC Status | Send controller status | 2 Bytes | 22.101 RHCC status | CRT |
| 21 | DPT_RTC combination status | Send controller status | 2 Bytes | 22.103 combined status RTC | CRT |
| 21 | DPT_RTSM combination status | Send controller status | 1 Byte | 21.107 combined status RTSM | CRT |
| 22 | Frost alarm | Send alarm | 1 Bit | 1.5 alarm | CRT |
| 23 | Heat alarm | Send alarm | 1 Bit | 1.5 alarm | CRT |
| 24 | Flow temperature Heating | Receive measured value | 2 Bytes | 9.1 temperature (°C) | CWT |
| 25 | Surface temperature Cooling | Receive measured value | 2 Bytes | 9.1 temperature (°C) | CWT |
| 25 | Dew point alarm | Receive alarm | 1 Bit | 1.5 alarm | CWT |
| 26 | Diagnosis | Status | 14 Bytes | 16.1 Character String (ISO 8859-1) | CRT |
| 27 | Window contact input | 0=closed / 1=open | 1 Bit | 1.19 window/door | CWTU |
| 27 | Window contact input | 1=closed / 0=open | 1 Bit | 1.1 switch | CWTU |
| 28 | Lock object Heating | Lock control value | 1 Bit | 1.3 enable | CRWTU |
| 29 | Lock object Cooling | Lock control value | 1 Bit | 1.3 enable | CRWTU |
| 30 | Dummy | 1 Bit | |||
| 31 | Dummy | 1 Bit | |||
| 32 | Switchover Heating/Cooling | 0=Cooling 1=Heating | 1 Bit | 1.100 cooling/heating | CRT |
| 32 | Switchover Heating/Cooling | 0=Cooling 1=Heating | 1 Bit | 1.100 cooling/heating | CW |
| 33 | Status Heating / Cooling | 0=Cooling 1=Heating | 1 Bit | 1.100 cooling/heating | CWTU |
| 33 | Status Heating / Cooling | 0=Cooling 1=Heating | 1 Bit | 1.100 cooling/heating | CRT |
| 34 | Heating request | Send request | 1 Bit | 1.1 switch | CRT |
| 35 | Cooling request | Send request | 1 Bit | 1.1 switch | CRT |
| 36 | Outdoor temperature / Reference value | Receive measured value | 2 Bytes | 9.1 temperature (°C) | CW |
| 37 | Reference control | Reference value in percent | 1 Byte | 5.1 percentage (0..100%) | CW |
| 37 | Reference control | Reference value in Lux | 2 Bytes | 9.4 lux (Lux) | CW |
| 38 | Reference control | Status | 1 Bit | 1.11 state | CRT |
| 39 | Reference control | Lock | 1 Bit | 1.3 enable | CW |
| 40 | Dummy | 1 Bit | |||
| 41 | Dummy | 1 Bit | |||
| 42 | Ventilation control | Lock | 1 Bit | 1.3 enable | CW |
| 43 | Ventilation control | Output Level 1 | 1 Bit | 1.1 switch | CRT |
| 43 | Ventilation control | Bit 0 | 1 Bit | 1.2 boolean | CRT |
| 44 | Ventilation control | Output Level 2 | 1 Bit | 1.1 switch | CRT |
| 44 | Ventilation control | Bit 1 | 1 Bit | 1.2 boolean | CRT |
| 44 | Ventilation control | Output Level 1+2 | 1 Bit | 1.1 switch | CRT |
| 45 | Ventilation control | Output Level 3 | 1 Bit | 1.1 switch | CRT |
| 45 | Ventilation control | Bit 2 | 1 Bit | 1.2 boolean | CRT |
| 45 | Ventilation control | Output Level 1+2+3 | 1 Bit | 1.1 switch | CRT |
| 46 | Ventilation control | Output Level 4 | 1 Bit | 1.1 switch | CRT |
| 46 | Ventilation control | Output Level 1+2+3+4 | 1 Bit | 1.1 switch | CRT |
| 47 | Ventilation control | 1Byte status ventilation level | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 47 | Ventilation control | 1Byte status ventilation level (Extension unit) | 1 Byte | 5.10 counter pulses (0..255) | CWTU |
| 48 | Ventilation control | Control value output | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 49 | Ventilation control | Object Priority | 1 Bit | 1.1 switch | CW |
| 50 | Ventilation control | Switch Automatic | 1 Bit | 1.1 switch | CRWT |
| 50 | Ventilation control | Switch Automatic (Extension unit) | 1 Bit | 1.1 switch | CT |
| 51 | Ventilation control | Change ventilation levels manually (+/-) | 1 Bit | 1.7 step | CWT |
| 52 | Ventilation control | Manual ventilation control | 1 Byte | 5.100 fan stage (0..255) | CWT |
| 52 | Ventilation control | Manual ventilation control (Extension unit) | 1 Byte | 5.100 fan stage (0..255) | CT |
| 53 | Ventilation control | Status ventilation active | 1 Bit | 1.11 state | CRT |
| 54 | Ventilation control | Status Automatic | 1 Bit | 1.11 state | CRT |
| 54 | Ventilation control | Status Automatic (Extension unit) | 1 Bit | 1.11 state | CWTU |
| 55 | Ventilation control | Relative air humidity input | 2 Bytes | 9.7 humidity (%) | CWTU |
| 56 | Dummy | 1 Bit | |||
| 57 | Dummy | 1 Bit | |||
| 58 | Temperature | Send measured value | 2 Bytes | 9.1 temperature (°C) | CRT |
| 59 | Temperature | External sensor input | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 60 | Temperature | Maximum value exceeded | 1 Bit | 1.5 alarm | CRT |
| 61 | Temperature | Minimum value fallen below | 1 Bit | 1.5 alarm | CRT |
| 62 | Buttons 1/2: {{0}} | Switch On/Off | 1 Bit | 1.1 switch | CT |
| 62 | Buttons 1/2: {{0}} | Dimming On/Off | 1 Bit | 1.1 switch | CT |
| 62 | Buttons 1/2: {{0}} | Blinds Up/Down | 1 Bit | 1.8 up/down | CT |
| 62 | Button 1: {{0}} | Switch | 1 Bit | 1.1 switch | CT |
| 62 | Button 1: {{0}} | Toggle | 1 Bit | 1.1 switch | CT |
| 62 | Button 1 short: {{0}} | Switch | 1 Bit | 1.1 switch | CT |
| 62 | Button 1 short: {{0}} | Toggle | 1 Bit | 1.1 switch | CT |
| 62 | Button 1 short: {{0}} | Send value | 1 Byte | 5.5 ratio (0..255) | CT |
| 62 | Button 1 short: {{0}} | Send percent value | 1 Byte | 5.1 percentage (0..100%) | CT |
| 62 | Button 1 short: {{0}} | Send scene | 1 Byte | 17.1 scene number | CT |
| 62 | Button 1 long: {{0}} | Dimming On/Off | 1 Bit | 1.1 switch | CT |
| 62 | Button 1: {{0}} | Blinds Up/Down | 1 Bit | 1.8 up/down | CT |
| 62 | Button 1: {{0}} | Send status | 1 Bit | 1.11 state | CT |
| 62 | Button 1: {{0}} | Send status | 1 Byte | 5.5 ratio (0..255) | CT |
| 62 | Button 1: {{0}} | Send percent value | 1 Byte | 5.1 percentage (0..100%) | CT |
| 62 | Button 1: {{0}} | Send scene | 1 Byte | 17.1 scene number | CT |
| 63 | Buttons 1/2: {{0}} | Dimming relative | 4 Bit | 3.7 dimming control | CT |
| 63 | Buttons 1/2: {{0}} | Slat adjustment / Stop | 1 Bit | 1.7 step | CT |
| 63 | Button 1: {{0}} | Status for toggle | 1 Bit | 1.1 switch | CWTU |
| 63 | Button 1 short: {{0}} | Status for toggle | 1 Bit | 1.1 switch | CWTU |
| 63 | Button 1: {{0}} | Dimming relative | 4 Bit | 3.7 dimming control | CT |
| 63 | Button 1: {{0}} | Slat adjustment / Stop | 1 Bit | 1.7 step | CT |
| 63 | Button 1 short: {{0}} | Status for display | 1 Bit | 1.1 switch | CWTU |
| 63 | Button 1 short: {{0}} | Status for display | 1 Byte | 5.5 ratio (0..255) | CWTU |
| 63 | Button 1 short: {{0}} | Status for display | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 64 | Button 1 long: {{0}} | Switch | 1 Bit | 1.1 switch | CT |
| 64 | Button 1 long: {{0}} | Toggle | 1 Bit | 1.1 switch | CT |
| 64 | Button 1 long: {{0}} | Send value | 1 Byte | 5.5 ratio (0..255) | CT |
| 64 | Button 1 long: {{0}} | Send percent value | 1 Byte | 5.1 percentage (0..100%) | CT |
| 64 | Button 1 long: {{0}} | Send scene | 1 Byte | 17.1 scene number | CT |
| 64 | Button 1: {{0}} | Status for toggle | 1 Bit | 1.1 switch | CWTU |
| 64 | Button 1: {{0}} | Status for change of direction | 1 Bit | 1.8 up/down | CWTU |
| 65 | Buttons 1/2: {{0}} | Status for display | 1 Bit | 1.11 state | CWTU |
| 65 | Buttons 1/2: {{0}} | Status for display | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 65 | Button 1 long: {{0}} | Status for toggle | 1 Bit | 1.11 state | CWTU |
| 65 | Button 1: {{0}} | Status for display | 1 Bit | 1.11 state | CWTU |
| 65 | Button 1: {{0}} | Status for display | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 65 | Button 1: {{0}} | Status for display | 1 Byte | 5.5 ratio (0..255) | CWTU |
| 66 | Buttons 1/2: {{0}} | Lock object | 1 Bit | 1.3 enable | CW |
| 66 | Button 1: Operating mode switching | Lock object | 1 Bit | 1.3 enable | CW |
| 66 | Button 1: Ventilation control | Lock object | 1 Bit | 1.3 enable | CW |
| 66 | Button 1: Control value = 0% | Lock object | 1 Bit | 1.3 enable | CW |
| 66 | Button 1: Heating / Cooling | Lock object | 1 Bit | 1.3 enable | CW |
| 66 | Button 1: {{0}} | Lock object | 1 Bit | 1.3 enable | CW |
| 67 | Button 2: {{0}} | Switch | 1 Bit | 1.1 switch | CRT |
| 67 | Button 2: {{0}} | Toggle | 1 Bit | 1.1 switch | CRT |
| 67 | Button 2 short: {{0}} | Switch | 1 Bit | 1.1 switch | CRT |
| 67 | Button 2 short: {{0}} | Toggle | 1 Bit | 1.1 switch | CRT |
| 67 | Button 2 short: {{0}} | Send value | 1 Byte | 5.5 ratio (0..255) | CRT |
| 67 | Button 2 short: {{0}} | Send percent value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 67 | Button 2 short: {{0}} | Send scene | 1 Byte | 17.1 scene number | CRT |
| 67 | Button 2: {{0}} | Dimming On/Off | 1 Bit | 1.1 switch | CRT |
| 67 | Button 2: {{0}} | Blinds Up/Down | 1 Bit | 1.8 up/down | CRT |
| 67 | Button 2: {{0}} | Send status | 1 Bit | 1.11 state | CRT |
| 67 | Button 2: {{0}} | Send value | 1 Byte | 5.5 ratio (0..255) | CRT |
| 67 | Button 2: {{0}} | Send percent value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 67 | Button 2: {{0}} | Send scene | 1 Byte | 17.1 scene number | CRT |
| 68 | Button 2: {{0}} | Status for toggle | 1 Bit | 1.1 switch | CWTU |
| 68 | Button 2 short: {{0}} | Status for toggle | 1 Bit | 1.1 switch | CWTU |
| 68 | Button 2: {{0}} | Dimming relative | 4 Bit | 3.7 dimming control | CRT |
| 68 | Button 2: {{0}} | Slat adjustment / Stop | 1 Bit | 1.7 step | CRT |
| 68 | Button 2: {{0}} | Status for display | 1 Bit | 1.1 switch | CWTU |
| 68 | Button 2: {{0}} | Status for display | 1 Byte | 5.5 ratio (0..255) | CWTU |
| 68 | Button 2: {{0}} | Status for display | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 69 | Button 2 long: {{0}} | Switch | 1 Bit | 1.1 switch | CRT |
| 69 | Button 2 long: {{0}} | Toggle | 1 Bit | 1.1 switch | CRT |
| 69 | Button 2 long: {{0}} | Send value | 1 Byte | 5.5 ratio (0..255) | CRT |
| 69 | Button 2 long: {{0}} | Send percent value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 69 | Button 2 long: {{0}} | Send scene | 1 Byte | 17.1 scene number | CRT |
| 69 | Button 2: {{0}} | Status for toggle | 1 Bit | 1.1 switch | CWTU |
| 69 | Button 2: {{0}} | Status for change of direction | 1 Bit | 1.8 up/down | CWTU |
| 70 | Button 2 long: {{0}} | Status for toggle | 1 Bit | 1.11 state | CWTU |
| 70 | Button 2: {{0}} | Status for display | 1 Bit | 1.11 state | CWTU |
| 70 | Button 2: {{0}} | Status for display | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 70 | Button 2: {{0}} | Status for display | 1 Byte | 5.5 ratio (0..255) | CWTU |
| 71 | Button 2: Operating mode switching | Lock object | 1 Bit | 1.3 enable | CW |
| 71 | Button 2: Ventilation control | Lock object | 1 Bit | 1.3 enable | CW |
| 71 | Button 2: Control value = 0% | Lock object | 1 Bit | 1.3 enable | CW |
| 71 | Button 2: Heating / Cooling | Lock object | 1 Bit | 1.3 enable | CW |
| 71 | Button 2: {{0}} | Lock object | 1 Bit | 1.3 enable | CW |
| 72 | Buttons 3/4: Setpoint shift | Lock object | 1 Bit | 1.3 enable | CW |
| 73 | LED 1 | Switch | 1 Bit | 1.1 switch | CWTU |
| 73 | LED 1 | Percent value | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 73 | LED 1 | Decimal value | 1 Byte | 5.5 ratio (0..255) | CWTU |
| 74 | LED 2 | Switch | 1 Bit | 1.1 switch | CWTU |
| 74 | LED 2 | Percent value | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 74 | LED 2 | Decimal value | 1 Byte | 5.5 ratio (0..255) | CWTU |
| 75 | LED 3 | Switch | 1 Bit | 1.1 switch | CWTU |
| 75 | LED 3 | Percent value | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 75 | LED 3 | Decimal value | 1 Byte | 5.5 ratio (0..255) | CWTU |
| 76 | LED 4 | Switch | 1 Bit | 1.1 switch | CWTU |
| 76 | LED 4 | Percent value | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 76 | LED 4 | Decimal value | 1 Byte | 5.5 ratio (0..255) | CWTU |
| 77 | LED 1 Priority | Switch | 1 Bit | 1.1 switch | CWTU |
| 78 | LED 2 Priority | Switch | 1 Bit | 1.1 switch | CWTU |
| 79 | LED 3 Priority | Switch | 1 Bit | 1.1 switch | CWTU |
| 80 | LED 4 Priority | Switch | 1 Bit | 1.1 switch | CWTU |
| 81 | LED | Lock object | 1 Bit | 1.3 enable | CWTU |
| 82 | Status text 1 | Input | 14 Bytes | 16.0 Character String (ASCII) | CWTU |
| 83 | Status text 2 | Input | 14 Bytes | 16.0 Character String (ASCII) | CWTU |
| 84 | Status value 1 | Switch On/Off | 1 Bit | 1.1 switch | CWTU |
| 84 | Status value 1 | Percent value 0…100% | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 84 | Status value 1 | Value 0…255 | 1 Byte | 5.5 ratio (0..255) | CWTU |
| 84 | Status value 1 | Value in mA | 2 Bytes | 7.12 current (mA) | CWTU |
| 84 | Status value 1 | Value in Lux | 2 Bytes | 7.13 brightness (lux) | CWTU |
| 84 | Status value 1 | Value in °C | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 84 | Status value 1 | Value in Lux | 2 Bytes | 9.4 lux (Lux) | CWTU |
| 84 | Status value 1 | Value in m/s | 2 Bytes | 9.5 speed (m/s) | CWTU |
| 84 | Status value 1 | Value in % | 2 Bytes | 9.7 humidity (%) | CWTU |
| 84 | Status value 1 | Value in ppm | 2 Bytes | 9.8 parts/million (ppm) | CWTU |
| 84 | Status value 1 | Value in mA | 2 Bytes | 9.21 current (mA) | CWTU |
| 85 | Status value 2 | Switch On/Off | 1 Bit | 1.1 switch | CWTU |
| 85 | Status value 2 | Percent value 0…100% | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 85 | Status value 2 | Value 0…255 | 1 Byte | 5.5 ratio (0..255) | CWTU |
| 85 | Status value 2 | Value in mA | 2 Bytes | 7.12 current (mA) | CWTU |
| 85 | Status value 2 | Value in Lux | 2 Bytes | 7.13 brightness (lux) | CWTU |
| 85 | Status value 2 | Value in °C | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 85 | Status value 2 | Value in Lux | 2 Bytes | 9.4 lux (Lux) | CWTU |
| 85 | Status value 2 | Value in m/s | 2 Bytes | 9.5 speed (m/s) | CWTU |
| 85 | Status value 2 | Value in % | 2 Bytes | 9.7 humidity (%) | CWTU |
| 85 | Status value 2 | Value in ppm | 2 Bytes | 9.8 parts/million (ppm) | CWTU |
| 85 | Status value 2 | Value in mA | 2 Bytes | 9.21 current (mA) | CWTU |
| 86 | Status value 3 | Switch On/Off | 1 Bit | 1.1 switch | CWTU |
| 86 | Status value 3 | Percent value 0…100% | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 86 | Status value 3 | Value 0…255 | 1 Byte | 5.5 ratio (0..255) | CWTU |
| 86 | Status value 3 | Value in mA | 2 Bytes | 7.12 current (mA) | CWTU |
| 86 | Status value 3 | Value in Lux | 2 Bytes | 7.13 brightness (lux) | CWTU |
| 86 | Status value 3 | Value in °C | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 86 | Status value 3 | Value in Lux | 2 Bytes | 9.4 lux (Lux) | CWTU |
| 86 | Status value 3 | Value in m/s | 2 Bytes | 9.5 speed (m/s) | CWTU |
| 86 | Status value 3 | Value in % | 2 Bytes | 9.7 humidity (%) | CWTU |
| 86 | Status value 3 | Value in ppm | 2 Bytes | 9.8 parts/million (ppm) | CWTU |
| 86 | Status value 3 | Value in mA | 2 Bytes | 9.21 current (mA) | CWTU |
| 87 | Operating | Output | 1 Bit | 1.11 state | CRT |
| 88 | Day / Night | Day = 1 / Night = 0 | 1 Bit | 1.1 switch | CWTU |
| 88 | Day / Night | Night = 1 / Day = 0 | 1 Bit | 1.24 day/night | CWTU |
| 89 | Presence | Input | 1 Bit | 1.1 switch | CWTU |
| 90 | Button operation | Output | 1 Bit | 1.11 state | CRT |
| 91 | Display | Brightness | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 91 | Display | Brightness | 1 Byte | 5.1 percentage (0..100%) | CW |
| 92 | LED | Flashing status | 1 Bit | 1.11 state | CT |
| 92 | LED | Flashing status | 1 Bit | 1.11 state | CW |
| 93 | Time | Receive current value | 3 Bytes | 10.1 time of day | CWTU |
| 94 | Date | Receive current value | 3 Bytes | 11.1 date | CWTU |
| 95 | Time / Date | Receive current value | 8 Bytes | 19.1 date time | CWTU |
| 96 | Dummy | 1 Bit | |||
| 97 | Dummy | 1 Bit | |||
| 98 | Dummy | 1 Bit | |||
| 99 | Dummy | 1 Bit | |||
| 100 | Dummy | 1 Bit | |||
| 101 | Dummy | 1 Bit | |||
| 102 | Dummy | 1 Bit | |||
| 103 | Dummy | 1 Bit | |||
| 104 | Dummy | 1 Bit | |||
| 105 | Dummy | 1 Bit |
Parameters (325)
| Parameter | Type | Default |
|---|---|---|
| Startup time | unsignedInt 2…240 | 2 |
| Send "Operation" cyclically | list | not active |
| Value for Day/Night | list | Day = 1 / Night = 0 |
| Status for toggle | list | request |
| Object Day/Night | list | request |
| Objects Time/Date | list | request |
| Language | list | German |
| Reaction time on keypress | list | fast |
| Time for long keypress | list | 0,4 s |
| Background colour | list | Day = white; Night = black |
| Font size: function name | list | big |
| Font size: labelling of buttons | list | small |
| Behaviour if the text is too long | list | text size is reduced |
| Behaviour at presence | list | display switched on |
| Adapt display brightness to ambience | list | active |
| Brightness at Day | list | 10% |
| Brightness at Night | list | 3% |
| Brightness | list | brightness level 8 |
| Minimum brightness for Day | list | 10% |
| Minimum brightness for Night | list | 3% |
| Overnight shutdown in Standby | list | threshold 2 (dark) |
| Red part | list | 0% |
| Green part | list | 0% |
| Blue part | list | 0% |
| User-defined colours | list | not active |
| Colour of orientation-LEDs in Standby | list | white |
| Time until Standby | unsignedInt 1…60 | 20 |
| Standby display | list | individually alternating |
| Change Standby display after | unsignedInt 1…60 | 5 |
| Standby display at Day | list | Standby in the upper screen |
| Status element 1 | list | Time (24 h) |
| Status element 2 | list | not active |
| Status element 3 | list | not active |
| Status element 4 | list | not active |
| Standby display at Night | list | behaviour like Day |
| Line 1 | list | one status element |
| Status element | list | Time (24 h) |
| Status element left | list | Time (24 h) |
| Status element right | list | status value 1 |
| Status element top | list | status text 1 (via object 82) |
| Status element bottom | list | status text 2 (via object 83) |
| Line 2 | list | not active |
| Action on button activation when display is OFF | list | Standby is exited |
| Action on button activation during Standby | list | function is not executed |
| Status value 1 | list | not active |
| Text for value = 0 | text | |
| Text for value = 1 | text | |
| Labelling "Unit" | text | |
| Labelling "Value" | text | |
| Status value 2 | list | not active |
| Status value 3 | list | not active |
| LED behaviour during Standby | list | LEDs OFF |
| Temperature measurement | list | active |
| Send measured value on change of... | list | 0,2 °C |
| Send measured value cyclically | list | 20 min |
| Sensor internal/external | list | internal 100% |
| Calibration value for internal sensor | signedInt -50…50 | 0 |
| Upper message value | list | not active |
| Lower message value | list | not active |
| Setpoint Comfort (Basic) | float 7…35 | 21 |
| Setpoint Standby | float 7…35 | 19 |
| Setpoint Night | float 7…35 | 18 |
| Setpoint Frost protection | float 3…12 | 7 |
| Maximum setpoint shift | float 0…10 | 3 |
| Setpoint Comfort (Basic) | float 7…35 | 23 |
| Setpoint Standby | float 7…35 | 24 |
| Setpoint Night | float 7…35 | 25 |
| Setpoint Heating protection | float 24…40 | 35 |
| Lower limit | float -10…10 | -3 |
| Upper limit | float -10…10 | 3 |
| Button/Object description | text | |
| Basic function | list | switch |
| Button assignment 1/2 | list | OFF / ON |
| Button assignment 1/2 | list | darker / brighter |
| Value | unsignedInt 0…255 | 0 |
| Button assignment 1/2 | list | UP / DOWN |
| Operating function | list | long=move / short=stop/slats open/close |
| Display | list | fixed text |
| Symbol for 0% | list | |
| Symbol colour for 0% | list | foreground colour (black/white) |
| Symbol for 0% - 90% | list | |
| Symbol colour for 0% - 90% | list | sun orange |
| Symbol for > 90% | list | |
| Symbol colour for > 90% | list | sun orange |
| Symbol for 10% - 90% | list | |
| Symbol colour for 10% - 90% | list | sun orange |
| Button labelling left | list | text entry |
| Button labelling right | list | text entry |
| Lock object | list | not active |
| Mode selection | list | Comfort / Standby / Night /Frost (Heat) protection |
| No switchover when other operating mode | unsignedInt 0…1 | 0 |
| Ventilation control | list | not active |
| Control as extension unit | list | not active |
| Total number of levels | list | 4 |
| Enable Automatic | list | not active |
| Subfunction | list | switch when button is pressed |
| Value for pressed button | list | ON |
| Action for short keypress - Object 1 | list | ON |
| Datapoint type | list | 1Byte DPT 5.005 Decimal factor (0...255) |
| Value | list | 0% |
| Scene number | list | 1 |
| Action for long keypress - Object 2 | list | not active |
| Value | list | 100% |
| Value for released button | list | OFF |
| Delay for released button | list | not active |
| Delay time | unsignedInt 1…3000 | 1 |
| HVAC Status object | list | HVAC Mode (DPT 20.102) |
| Symbol for "Eco/Night" | list | Eco symbol |
| Symbol colour for mode "Eco" | list | sun orange |
| Symbol colour for "Frost/Heat protection" | list | sun orange |
| Symbol for level 0 | list | |
| Symbol for level > 0 | list | |
| Symbol for Automatic | list | |
| Symbol for Unlocked / Active | list | |
| Symbol colour for Unlocked / Active | list | foreground colour (black/white) |
| Symbol for Locked / Inactive (0%) | list | |
| Symbol for "Cooling" | list | |
| Symbol for "Heating" | list | |
| Cyclical sending | list | not active |
| Send cyclically every | unsignedInt 1…3000 | 1 |
| Symbol colour for "Comfort" | list | foreground colour (black/white) |
| Symbol colour for "Standby" | list | sun orange |
| Symbol colour for "Eco" | list | sun orange |
| Symbol colour for "Night" | list | sun orange |
| Symbol colour for Locked / Inactive (0%) | list | sun orange |
| Symbol colour for "Cooling" | list | foreground colour (black/white) |
| Symbol colour for "Heating" | list | sun orange |
| Symbol for "OFF" | list | |
| Symbol colour for "OFF" | list | foreground colour (black/white) |
| Symbol for "ON" | list | |
| Symbol colour for "ON" | list | sun orange |
| Symbol for 0 | list | |
| Symbol colour for 0 | list | foreground colour (black/white) |
| Symbol for 1 - 230 | list | |
| Symbol colour for 1 - 230 | list | sun orange |
| Symbol for > 230 | list | |
| Symbol colour for > 230 | list | sun orange |
| Symbol colour for 0% | list | foreground colour (black/white) |
| Symbol colour for Scene | list | foreground colour (black/white) |
| Use device as | list | Controller |
| Operating mode | list | Heating |
| Function button 1 | list | mode selection (internal connection) |
| Function button 2 | list | switchover Heating/Cooling (internal connection) |
| System | list | 2 pipe / 1 circuit (Heating or Cooling) |
| Priority | list | Frost(Heat) protection/Comfort/Night/Standby |
| Setpoints for Standby/Night | list | depending on setpoint Comfort (Basic) |
| Standby reduction | list | 2,0 K |
| Night reduction | list | 3,0 K |
| Separate objects for setpoints Comfort/Standby/Night/Frost protection | list | not active |
| Setpoint shift via 1Bit/1Byte object | list | 1Bit |
| Step width | list | 0,5 K |
| Status setpoint shift | list | not active |
| Setpoint shift applies to | list | Comfort |
| Action when shifting in Night/Standby | list | no action |
| Delete setpoint shift after change of operating mode | list | not active |
| Delete setpoint shift after new absolute setpoint | list | active |
| Reset setpoints to parameterization after operating mode change | list | active |
| Reset basic setpoint to configured value after change of operation mode | list | active |
| Delete setpoint shift after new basic setpoint | list | active |
| Send setpoint changes | list | active |
| Send current setpoint cyclically | list | not active |
| Comfort extention with time | list | not active |
| Comfort extention time | list | not active |
| Operating mode after reset | list | Comfort with configured setpoint |
| Operating mode after reprogramming | list | Comfort |
| Additional HVAC Status object | list | not active |
| Send HVAC Status object cyclically | list | not active |
| Lock object for control value Heating | list | not active |
| Object for Heating request | list | not active |
| Flow temperature | list | not active |
| Limit flow temperature to | unsignedInt 10…60 | 40 |
| Standby increase | list | 2,0 K |
| Night increase | list | 3,0 K |
| Separate objects for setpoints of Comfort/Standby/Night Heating protection | list | not active |
| Lock object for control value Cooling | list | not active |
| Object for Cooling request | list | not active |
| Limit temperature of cooling medium | list | not active |
| Minimum temperature cooling medium | unsignedInt 0…60 | 10 |
| Switchover Heating/Cooling | list | automatically |
| Dead zone between Heating and Cooling | list | 2,0 K |
| Dead zone between Heating and Cooling | list | 0 K |
| Separate objects for setpoints Comfort/Standby/Night/Frost protection/Heating protection | list | not active |
| Operating mode after reprogramming | list | Comfort (Cooling) |
| Alarms | list | not active |
| Frost alarm if value less | unsignedInt 3…10 | 7 |
| Heat alarm if value greater | unsignedInt 25…40 | 35 |
| Window contact | list | not active |
| State of window | list | 0=closed / 1=open (standard DPT) |
| Delay time | unsignedInt 0…240 | 5 |
| Action when opening the window | list | force Frost/Heat protection |
| Action when closing the window | list | HVAC Modus before locking |
| Release time | list | 12 h |
| Control value | list | PI control continuous |
| Direction of controller | list | normal |
| Maximum value of control value | list | 100% |
| Heating system | list | Underfloor Heating (4K / 150min) |
| Proportional range | list | 4 K |
| Reset time | list | 150 min |
| PWM cycle | list | 10 min |
| Switching hysteresis | list | 2,0 K |
| Send control value cyclically | list | 5 min |
| Additional level | list | not active |
| Direction of action with rising temperature | list | normal |
| Control value | list | 2-step control (switching) |
| Distance | list | 2,0 K |
| Cooling system | list | Cooling ceiling (4K / 150min) |
| Send outputs cyclically every | list | not active |
| Pause between individual levels [x100ms] | unsignedInt 0…255 | 0 |
| Type of thresholds | list | control value |
| Minimum level for Day | list | Level 0 |
| Maximum level for Day | list | Level 2 |
| Minimum level for Night | list | Level 0 |
| Maximum level for Night | list | Level 2 |
| Maximum level for Day | list | Level 3 |
| Maximum level for Night | list | Level 3 |
| Maximum level for Day | list | Level 4 |
| Maximum level for Night | list | Level 4 |
| Threshold level 1 | list | 10% |
| Threshold level 2 | list | 30% |
| Threshold level 3 | list | 50% |
| Threshold level 4 | list | 70% |
| Output value (level 1) for Day | list | 10% |
| Output value (level 1) for Night | list | 10% |
| Output value (level 2) for Day | list | 30% |
| Output value (level 2) for Night | list | 30% |
| Output value (level 3) for Day | list | 50% |
| Output value (level 3) for Night | list | 50% |
| Output value (level 4) for Day | list | 70% |
| Output value (level 4) for Night | list | 70% |
| Hysteresis | list | 5% |
| Threshold level 1 | list | 2,0 K |
| Threshold level 2 | list | 4,0 K |
| Threshold level 3 | list | 6,0 K |
| Threshold level 4 | list | 8,0 K |
| Hysteresis | list | 0,5 K |
| Behaviour at lock | list | not active |
| Behaviour when unlocking | list | not active |
| Level when unlocking | list | Level 0 |
| Level at lock | list | Level 0 |
| Release time (manual => automatic) | list | not active |
| Behaviour on reset | list | automatic mode |
| Sticking protection | list | not active |
| Priority | list | not active |
| Switch priority with | list | Level 0 |
| Function buttons 1/2 | list | not active |
| Function buttons 3/4 (-/+) | list | temperature shift |
| Step width of setpoint shift | float 0.1…1 | 0.5 |
| Lower limit | float 0…45 | 19 |
| Upper limit | float 0…45 | 23 |
| Temperature shift | list | 1Bit |
| Switchover considers status object | list | active |
| Repeated sending with pressed button | list | 1 s |
| Repetition time | list | 1 s |
| Text | text | |
| Symbol colour for level 0 | list | foreground colour (black/white) |
| Symbol colour for level > 0 | list | sun orange |
| Symbol colour for Automatic | list | sun orange |
| Symbol for Scene | list | |
| Symbol | list | Heating/Cooling |
| Display control value | list | not active |
| Symbol colour for Heating | list | foreground colour (black/white) |
| Symbol colour for control value > 0% (Heating) | list | foreground colour (black/white) |
| Symbol colour for Cooling | list | foreground colour (black/white) |
| Symbol colour for control value = 0% (Heating) | list | foreground colour (black/white) |
| Symbol colour for control value = 0% (Cooling) | list | foreground colour (black/white) |
| Symbol for Eco/Night mode | list | Eco symbol |
| Symbol colour for Comfort | list | foreground colour (black/white) |
| Symbol colour for Standby | list | foreground colour (black/white) |
| Symbol colour for Eco/Night | list | foreground colour (black/white) |
| Symbol colour for Frost/Heat protection | list | foreground colour (black/white) |
| Labelling (Controller function) | text | |
| Symbol colour for control value > 0% (Cooling) | list | foreground colour (black/white) |
| LED | list | active |
| LED reacts to: | list | button activation |
| Request external object cyclically | list | not active |
| Datapoint type | list | 1Bit DPT 1.001 Switch |
| ON if greater than | list | 50% |
| Selection of object number | unsignedInt 0…100 | 0 |
| Colour for Day (value ON) | list | white |
| Colour for Day (value OFF) | list | black |
| Behaviour for Day (value ON) | list | permanent |
| Colour for Night (value ON) | list | white |
| Colour for Night (value OFF) | list | black |
| Behaviour for Night (value ON) | list | permanent |
| Object for priority | list | not active |
| Colour for Day | list | white |
| Colour for Night | list | white |
| Lock object for LEDs | list | not active |
| LED colour on button activation, only with setting "Object and button activation" | list | black |
| Function name | text | |
| Display status value as text under symbol | list | in percent (%) |
| Display status value as text under symbol | list | without unit |
| Status display | list | setpoint temperature (big) |
| Synchronisation object for flashing LEDs | list | not active |
| Send brightness via object to the bus | list | not active |
| Labelling "Internal temperature" | text | |
| Labelling "Time" | text | |
| Behaviour on reset | list | Level 1 |
| Behaviour of LEDs on bus power return | list | do not request LED objects |
| Text for "Comfort" | text | |
| Text for "Standby" | text | |
| Text for "Eco/Night" | text | |
| Text for "Frost alarm" | text | |
| Text for "Unlocked / Active" | text | |
| Text for "Locked / Inactive" | text | |
| Text for "Cooling" | text | |
| Text for "Heating" | text | |
| Text for "OFF" | text | |
| Text for "ON" | text | |
| Text for "On" | text | |
| Reference control | list | not active |
| Reference variable minimum | unsignedInt 10…60 | 28 |
| Reference variable maximum | unsignedInt 10…60 | 38 |
| Setpoint change at maximum reference variable | float -5…-0.5 | -2 |
| Reference variable minimum | list | 0% |
| Reference variable maximum | list | 100% |
| Threshold outdoor temperature | list | not active |
| Reference control released from | unsignedInt 5…35 | 15 |
| Reference variable minimum | list | 30000 Lux |
| Reference variable maximum | list | 80000 Lux |
| Current setpoint considers "Reference control" | list | not active |
| Setpoint change at maximum reference variable | float 1…10 | 10 |
| Position of buttons | picture | |
| Cleaning function | list | active |
| Position of LEDs | picture |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Glass Temperature Controller Smart 1.2 latest | $0247 | B13D | 2026-11-25 | 326 KB | Download |
About this file
This is the official ETS product database for the MDT technologies GmbH SCN-RTRGx.02 Glass Room Temperature Controller Smart with Colour display (SCN-RTRGx.02), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from MDT technologies GmbH
- SCN-LSD01.01 Brightness Sensor/Controller SCN-LSD01.01
- SCN-MGSUP.01 Air quality/CO2 sensor SCN-MGSUP.01
- Glass Room temperature controller SCN-RT1Gx.01
- Room Temperature Controller 1-fold UP SCN-RT1UP.01
- Room Temp. Contr. 1-fold with adjustment knob UP SCN-RT1UPE.01
- Temperature controller / sensor 2-fold UP SCN-RT2UP.01
- Temperature controller / sensor 4-fold UP SCN-RT4UP.01
- Controller / Sensor 6-fold AP SCN-RT6AP.01
- Temperature Controller 6-fold, 2SU MDRC SCN-RT6REG.01
- SCN-RT8REG.02 Temperature Controller 8-fold MDRC SCN-RT8REG.02
- SCN-RTN55S.01 Room Temperature Extension Unit Smart 55 SCN-RTN55S.01
- SCN-RTN60S.01 Room Temperature Extension Unit Smart 60 CH SCN-RTN60S.01