HDL MHVACSGW 2508 MHVACSGW-KT.13

MHVACSGW-KT.13 MHVACSGW 2508

HDL · Order number MHVACSGW 2508 · Environment

HDL KNX Indoor AC Gateway - KNX

Download .knxprod Indoor AC Gateway 1.0 · 123 KB

Product

ManufacturerHDL
Product nameMHVACSGW-KT.13
Order numberMHVACSGW 2508
HardwareMHVACSGW-KT.13
MediumTwisted Pair
Bus current (mA)15
Rail mountedYes
RegistrationRegistered · 2026-01-05
Languagesen-US, zh-CN
Catalog entryM-0073_H-MHVACSGW.202508-1_HP-2340-10-CE2A_CI-MHVACSGW.202508-1
FingerprintCE2A
SHA-2569e610842a3508d9ad8aa1212ce4442704cab83cdd677b00dfd209a48cb15a922
First seen2026-11-25
Markets69 markets

Application program: Indoor AC Gateway 1.0

Application number$2340
Version1.0
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Parameters134
Group objects58
Group objects (58)
NoNameFunctionSizeDPTFlags
1GeneralHeartbeat telegram1 Bit1.3 enableCT
2Air Condition 1AC Switch ON/OFF(1bit)1 Bit1.1 switchCWTU
3Air Condition 1AC Switch ON/OFF Status(1bit)1 Bit1.1 switchCRWTU
4Air Condition 1AC Control Mode(1byte)1 Byte20.105 HVAC control modeCWTU
5Air Condition 1AC Control Mode Status(1byte)1 Byte20.105 HVAC control modeCRWTU
6Air Condition 1AC Humidity(1byte)1 Byte5.1 percentage (0..100%)CWTU
7Air Condition 1AC Humidity Status(1byte)1 Byte5.1 percentage (0..100%)CRWTU
8Air Condition 1AC Circular Breath(1byte)1 Byte5.1 percentage (0..100%)CWTU
9Air Condition 1AC Circular Breath Status1 Byte5.1 percentage (0..100%)CRWTU
10Air Condition 1AC Temperature Setpoint2 Bytes9.1 temperature (°C)CWTU
11Air Condition 1AC Temperature Setpoint Status2 Bytes9.1 temperature (°C)CRWTU
12Air Condition 1AC Speed(1byte)1 Byte5.1 percentage (0..100%)CWTU
13Air Condition 1AC Speed Status(1byte)1 Byte5.1 percentage (0..100%)CRWTU
14Air Condition 1AC Room Temperature(2byte)2 Bytes9.1 temperature (°C)CRWTU
15Air Condition 1AC Online/Offline Status(1bit)1 Bit1.1 switchCRWTU
16Air Condition 1AC Fault stutus(1bit)1 Bit1.1 switchCRWTU
17Air Condition 1AC Swing Mode(1byte)1 Byte5.100 fan stage (0..255)CWTU
18Air Condition 1AC Swing Mode Status(1byte)1 Byte5.100 fan stage (0..255)CRWTU
19Air Condition 1AC Clean Filter Reset(1bit)1 Bit1.1 switchCWTU
20Air Condition 1AC Clean Filter Reset Status1 Bit1.1 switchCRWTU
21Fresh Air 1Switch ON/OFF(1bit)1 Bit1.1 switchCWTU
22Fresh Air 1Switch ON/OFF Status(1bit)1 Bit1.1 switchCRWTU
23Fresh Air 1Mode(1byte)1 Byte5.1 percentage (0..100%)CWTU
24Fresh Air 1Mode Status(1byte)1 Byte5.1 percentage (0..100%)CRWTU
25Fresh Air 1Fan Speed(1byte)1 Byte5.1 percentage (0..100%)CWTU
26Fresh Air 1Fan Speed Status(1byte)1 Byte5.1 percentage (0..100%)CRWTU
27Fresh Air 1Setpoint Temperature(2byte)2 Bytes9.1 temperature (°C)CWTU
28Fresh Air 1Setpoint Temperature Status2 Bytes9.1 temperature (°C)CRWTU
29Fresh Air 1Room Temperature(2byte)2 Bytes9.1 temperature (°C)CRWTU
30Fresh Air 1Air PM2.5(2byte)2 Bytes9.30 concentration (µg/m³)CRWTU
31Fresh Air 1Air VOC(2byte)2 Bytes9.30 concentration (µg/m³)CRWTU
32Fresh Air 1Air CO2(2byte)2 Bytes9.30 concentration (µg/m³)CRWTU
33Fresh Air 1Online/Offline Status(1bit)1 Bit1.1 switchCRWTU
34Fresh Air 1Fault stutus(1bit)1 Bit1.1 switchCRWTU
35Fresh Air 1Clean Filter Reset(1bit)1 Bit1.1 switchCWTU
36Fresh Air 1Clean Filter Reset Status1 Bit1.1 switchCRWTU
37Heating 1Switch ON/OFF1 Bit1.1 switchCWTU
38Heating 1Switch ON/OFF Status1 Bit1.1 switchCRWTU
39Heating 1Normal Mode ON/OFF1 Bit1.1 switchCWTU
40Heating 1Normal Mode ON/OFF Status1 Bit1.1 switchCRWTU
41Heating 1Day Mode ON/OFF1 Bit1.1 switchCWTU
42Heating 1Day Mode ON/OFF Status1 Bit1.1 switchCRWTU
43Heating 1Night Mode ON/OFF1 Bit1.1 switchCWTU
44Heating 1Night Mode ON/OFF Status1 Bit1.1 switchCRWTU
45Heating 1Away Mode ON/OFF1 Bit1.1 switchCWTU
46Heating 1Away Mode ON/OFF Status1 Bit1.1 switchCRWTU
47Heating 1Timer Mode ON/OFF1 Bit1.1 switchCWTU
48Heating 1Timer Mode ON/OFF Status1 Bit1.1 switchCRWTU
49Heating 1Mute Mode ON/OFF1 Bit1.1 switchCWTU
50Heating 1Mute Mode ON/OFF Status1 Bit1.1 switchCRWTU
51Heating 1Frost protection mode1 Bit1.1 switchCWTU
52Heating 1Frost protection mode Status1 Bit1.1 switchCRWTU
53Heating 1Temperature Setpoint2 Bytes9.1 temperature (°C)CWTU
54Heating 1Temperature Setpoint Status2 Bytes9.1 temperature (°C)CRWTU
55Heating 1Room Temperature(2byte)2 Bytes9.1 temperature (°C)CRWTU
56Heating 1Outdoor Temperature(2byte)2 Bytes9.1 temperature (°C)CRWTU
57Heating 1Online/Offline Status(1bit)1 Bit1.1 switchCRWTU
58Heating 1Fault stutus(1bit)1 Bit1.1 switchCRWTU
Parameters (110)
ParameterTypeDefault
Operation delay after power on(2..200s)unsignedInt 2…2552
Heartbeat telegramlistDisable
NULLlistDisable
>Telegram is sent time interval(1..65535s)unsignedInt 1…6553560
Work modelistPlease select
Baud ratelist19200
ParitylistNone
Data bitslist8 bits
Stop bitslist1 bit
AC Online/Offline reportlistDisable
AC Fault stutus reportlistDisable
AC Room temperature reportlistDisable
Control modelistStandard
Advanced control modelistDisable
--> FanunsignedInt 0…2559
--> HeatunsignedInt 0…2551
--> CoolunsignedInt 0…2553
--> DehumidificationunsignedInt 0…25514
--> SleepunsignedInt 0…255255
--> DryunsignedInt 0…255255
--> Fresh and coolunsignedInt 0…255255
--> Auto dehumidificationunsignedInt 0…255255
--> Strong heatingunsignedInt 0…255255
--> Heating_floorunsignedInt 0…255255
--> PreheatunsignedInt 0…255255
HumiditylistDisable
--> Humidity_OFFunsignedInt 0…2550
--> Humidity_1unsignedInt 0…25575
--> Humidity_2unsignedInt 0…255155
--> Humidity_3unsignedInt 0…255255
Circular breathinglistDisable
--> OFFunsignedInt 0…2550
--> StrongunsignedInt 0…255255
--> WeakunsignedInt 0…25555
--> AutounsignedInt 0…25551
--> HighunsignedInt 0…255204
--> Mid-HighunsignedInt 0…255180
--> MidunsignedInt 0…255153
--> Mid-LowunsignedInt 0…255125
--> LowunsignedInt 0…255102
--> SuperstrongunsignedInt 0…255255
--> UltrstaticunsignedInt 0…25551
SwinglistDisable
--> Swing up down and left rightunsignedInt 0…2550
--> Swing up down P1unsignedInt 0…2551
--> Swing up down P2unsignedInt 0…2552
--> Swing up down P3unsignedInt 0…2553
--> Swing up down P4unsignedInt 0…2554
--> Swing up down P5unsignedInt 0…2555
--> Swing up down P6unsignedInt 0…2556
--> Swing left right P1unsignedInt 0…2557
--> Swing left right P2unsignedInt 0…2558
--> Swing left right P3unsignedInt 0…2559
--> Swing left right P4unsignedInt 0…25510
--> Swing left right P5unsignedInt 0…25511
--> Swing left right P6unsignedInt 0…25512
--> Set temperature MinunsignedInt 0…320
--> Set temperature MaxunsignedInt 0…3232
Clean filterlistDisable
Fresh Online/Offline reportlistDisable
Fresh Fault stutus reportlistDisable
Fresh Room temperature reportlistDisable
Fresh Air quality reportlistDisable
--> ChangeunsignedInt 0…2551
--> ExhaustunsignedInt 0…2552
--> SmartunsignedInt 0…2553
--> StrongunsignedInt 0…2554
--> Blowing-inunsignedInt 0…255255
--> BypassunsignedInt 0…255255
--> Quick cleanunsignedInt 0…255255
--> ComfortunsignedInt 0…255255
--> Cool breezeunsignedInt 0…255255
--> Manual operationunsignedInt 0…255255
--> SilenceunsignedInt 0…255255
--> Fresh airunsignedInt 0…255255
--> CoolunsignedInt 0…255255
--> HeatunsignedInt 0…255255
--> DehumidificationunsignedInt 0…255255
--> Heat exchangeunsignedInt 0…255255
--> Internal recycleunsignedInt 0…255255
--> Outside loopunsignedInt 0…255255
--> Mixed airunsignedInt 0…255255
--> CloseunsignedInt 0…255255
--> Fresh air dehumidifiesunsignedInt 0…255255
--> TmingunsignedInt 0…255255
--> Haze removalunsignedInt 0…255255
--> DefrostunsignedInt 0…255255
--> Internal dehumidificationunsignedInt 0…255255
--> AutounsignedInt 0…255102
--> Mid-LowunsignedInt 0…255120
--> CloseunsignedInt 0…2550
Heat Online/Offline reportlistDisable
Heat Fault stutus reportlistDisable
Heat Room temperature reportlistDisable
Heat Temperature sensorlistDisable
Heat Frost protection modelistDisable
--> ON/OFF Valuelist1-ON/0-OFF
Normal ModelistDisable
--> Normal Mode Default TempunsignedInt 0…25525
Day ModelistDisable
--> Day Mode Default TempunsignedInt 0…25525
Night ModelistDisable
--> Night Mode Default TempunsignedInt 0…25525
Away ModelistDisable
--> Away Mode Default TempunsignedInt 0…25525
Timer ModelistDisable
--> Timer Mode Default TempunsignedInt 0…25525
MutelistDisable
--> Set temperature MinunsignedInt 0…550
--> Set temperature MaxunsignedInt 0…5555

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Indoor AC Gateway 1.0 latest$2340CE2A2026-11-25123 KBDownload

About this file

This is the official ETS product database for the HDL MHVACSGW-KT.13 (MHVACSGW 2508), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.