KNX Database
HDL M/FCU01 1206 F001 M/FCU01.10.1

M/FCU01.10.1 M/FCU01 1206 F001

HDL · Order number M/FCU01 1206 F001 · Environment

HDL DIN Rail FCU & 7CH Heating - KNX

Download .knxprod FCU & Floor Heating Actuator(V2.0) 2.0 · 376 KB

Product

ManufacturerHDL
Product nameM/FCU01.10.1
Order numberM/FCU01 1206 F001
HardwareM/FCU01.10.1
MediumTwisted Pair
Bus current (mA)20
Rail mountedYes
RegistrationCertified · 2017-05-08
Languagesen-US, zh-CN
Catalog entryM-0073_H-M.2FFCU01.201206.20F001-10_HP-2240-20-6117_CI-M.2FFCU01.201206.20F001-4
Fingerprint6117
SHA-256c6e92ad5103b2468148da302da909ffc216cf12150952ae977bcae821c1e5821
First seen2026-11-25
Markets69 markets

Application program: FCU & Floor Heating Actuator(V2.0) 2.0

Application number$2240
Version2.0
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version3.0f
Parameters1414
Group objects396
Group objects (396)
NoNameFunctionSizeDPTFlags
1GeneralSend cycles1 Bit1.3 enableCRT
2Slave clockNetwork datetime8 Bytes19.1 date timeCWTU
3Slave clockNetwork date3 Bytes11.1 dateCWTU
4Slave clockNetwork time of day3 Bytes10.1 time of dayCWTU
5Floor heatingPipe pressure protection1 Bit1.1 switchCRT
6Floor heating AActual temperature2 Bytes9.1 temperature (°C)CRWTU
6Floor heating AControl value A1 Byte5.1 percentage (0..100%)CWTU
7Floor heating AActual temp. error signal1 Bit1.5 alarmCRT
7Floor heating AControl value error signal1 Bit1.5 alarmCRT
8Floor heating ANormal-mode setpoint Temp.2 Bytes9.1 temperature (°C)CRWTU
9Floor heating ADay-mode setpoint Temp.2 Bytes9.1 temperature (°C)CRWTU
10Floor heating ANight-mode setpoint Temp.2 Bytes9.1 temperature (°C)CRWTU
11Actual temperatureActual temperature 12 Bytes9.1 temperature (°C)CRWTU
11Floor heating AAway-mode setpoint Temp.2 Bytes9.1 temperature (°C)CRWTU
12Actual temperatureActual temperature 22 Bytes9.1 temperature (°C)CRWTU
12Floor heating APreset 1 Temp. for timer mode2 Bytes9.1 temperature (°C)CRWTU
13Actual temperatureActual temperature 32 Bytes9.1 temperature (°C)CRWTU
13Floor heating ATime of day for preset 13 Bytes10.1 time of dayCRWT
14Actual temperatureActual temperature 42 Bytes9.1 temperature (°C)CRWTU
14Floor heating AStart/Stop heating for preset11 Bit1.10 start/stopCRWT
15Actual temperatureActual temp. 1 error signal1 Bit1.5 alarmCRT
15Floor heating APreset 2 Temp. for timer mode2 Bytes9.1 temperature (°C)CRWTU
16Actual temperatureActual temp. 2 error signal1 Bit1.5 alarmCRT
16Floor heating ATime of day for preset 23 Bytes10.1 time of dayCRWT
17Actual temperatureActual temp. 3 error signal1 Bit1.5 alarmCRT
17Floor heating AStart/Stop heating for preset21 Bit1.10 start/stopCRWT
18Actual temperatureActual temp. 4 error signal1 Bit1.5 alarmCRT
18Floor heating APreset 3 Temp. for timer mode2 Bytes9.1 temperature (°C)CRWTU
19Actual temperatureFrost/heat alarm error signal1 Bit1.5 alarmCRT
19Floor heating ATime of day for preset 33 Bytes10.1 time of dayCRWT
20Floor heating AStart/Stop heating for preset31 Bit1.10 start/stopCRWT
20SystemSystem ON/OFF(1-ON,0-OFF)1 Bit1.1 switchCW
21SetpointBase setpoint temperature2 Bytes9.1 temperature (°C)CWU
21Floor heating AFloor heating(1-ON,0-OFF)1 Bit1.1 switchCRWT
21SystemStatus system ON/OFF1 Bit1.1 switchCRT
21Floor heating AFloor heating(1-ON,0-OFF)1 Bit1.1 switchCW
22SetpointBase setpoint temp. step1 Bit1.7 stepCWU
22Floor heating AON CMD for Normal-mode1 Bit1.1 switchCRWT
22Control value AHeating/Cooling value1 Byte5.1 percentage (0..100%)CWTU
22Control value AHeating value1 Byte5.1 percentage (0..100%)CWTU
23Floor heating AON CMD for Day-mode1 Bit1.1 switchCRWT
23Control value BHeating/Cooling value1 Byte5.1 percentage (0..100%)CWTU
23Control value BCooling value1 Byte5.1 percentage (0..100%)CWTU
24Floor heating AON CMD for Night-mode1 Bit1.1 switchCRWT
24Switch heat/cool1'-heat valve,'0'-cool valve1 Bit1.1 switchCWTU
24Switch heat/cool0'-heat valve,'1'-cool valve"1 Bit1.1 switchCWTU
24Switch A/B1'-A,'0'-B1 Bit1.1 switchCWTU
24Switch A/B0'-A,'1'-B1 Bit1.1 switchCWTU
25HVAC control modeHVAC control mode (byte)1 Byte20.105 HVAC control modeCW
25Floor heating AON CMD for Away-mode1 Bit1.1 switchCRWT
25Control valueControl value error signal1 Bit1.5 alarmCRT
26HVAC control modeAutomatic heating/cooling mode1 Bit1.3 enableCW
26Floor heating AON CMD for Timer-mode1 Bit1.1 switchCRWT
27HVAC control modeHeating mode1 Bit1.3 enableCW
27Floor heating AStatus value1 Bit1.1 switchCRT
28HVAC control modeCooling mode1 Bit1.3 enableCW
28Floor heating ATrigger valve purge1 Bit1.17 triggerCW
29HVAC control modeOff mode1 Bit1.3 enableCW
29Floor heating AStatus valve purge1 Bit1.3 enableCRT
30HVAC control modeFan only mode1 Bit1.3 enableCW
30Floor heating AStatus of base setpoint temp.2 Bytes9.1 temperature (°C)CRT
31HVAC operation modeHVAC operation mode (byte)1 Byte20.102 HVAC modeCW
31Floor heating BActual temperature2 Bytes9.1 temperature (°C)CRWTU
31Floor heating BControl value B1 Byte5.1 percentage (0..100%)CWTU
32HVAC operation modeComfort mode1 Bit1.1 switchCW
32Floor heating BActual temp. error signal1 Bit1.5 alarmCRT
32Floor heating BControl value error signal1 Bit1.5 alarmCRT
33HVAC operation modeStandby mode1 Bit1.1 switchCW
33Floor heating BNormal-mode setpoint Temp.2 Bytes9.1 temperature (°C)CRWTU
34HVAC operation modeEconomy mode1 Bit1.1 switchCW
34Floor heating BDay-mode setpoint Temp.2 Bytes9.1 temperature (°C)CRWTU
35HVAC operation modeBuilding protection mode1 Bit1.1 switchCW
35Floor heating BNight-mode setpoint Temp.2 Bytes9.1 temperature (°C)CRWTU
36Floor heating BAway-mode setpoint Temp.2 Bytes9.1 temperature (°C)CRWTU
37HVAC Energy saving functionTrigger1 Bit1.17 triggerCW
37Floor heating BPreset 1 Temp. for timer mode2 Bytes9.1 temperature (°C)CRWTU
38HVAC Energy saving functionChange delay time2 Bytes8.6 time lag (min)CW
38Floor heating BTime of day for preset 13 Bytes10.1 time of dayCRWT
39HVAC Energy saving functionChange saving mode1 Byte20.102 HVAC modeCW
39Floor heating BStart/Stop heating for preset11 Bit1.10 start/stopCRWT
40Floor heating BPreset 2 Temp. for timer mode2 Bytes9.1 temperature (°C)CRWTU
41FanFan speed automatic1 Bit1.3 enableCW
41FanFan speed automatic1 Bit1.3 enableCWT
41Floor heating BTime of day for preset 23 Bytes10.1 time of dayCRWT
42FanFan speed with % value1 Byte5.1 percentage (0..100%)CW
42FanFan speed with 0-3 value1 Byte5.10 counter pulses (0..255)CW
42FanFan speed with % value1 Byte5.1 percentage (0..100%)CWT
42FanFan speed with 0-3 value1 Byte5.10 counter pulses (0..255)CWT
42Floor heating BStart/Stop heating for preset21 Bit1.10 start/stopCRWT
43FanFan speed 11 Bit1.1 switchCW
43FanFan speed 11 Bit1.1 switchCWT
43Floor heating BPreset 3 Temp. for timer mode2 Bytes9.1 temperature (°C)CRWTU
44FanFan speed 21 Bit1.1 switchCW
44FanFan speed 21 Bit1.1 switchCWT
44Floor heating BTime of day for preset 33 Bytes10.1 time of dayCRWT
45FanFan speed 31 Bit1.1 switchCW
45Floor heating BStart/Stop heating for preset31 Bit1.10 start/stopCRWT
46FanStatus fan speed 11 Bit1.1 switchCRT
46Floor heating BFloor heating(1-ON,0-OFF)1 Bit1.1 switchCRWT
46Floor heating BFloor heating(1-ON,0-OFF)1 Bit1.1 switchCW
47FanStatus fan speed 21 Bit1.1 switchCRT
47Floor heating BON CMD for Normal-mode1 Bit1.1 switchCRWT
48FanStatus fan speed 31 Bit1.1 switchCRT
48Floor heating BON CMD for Day-mode1 Bit1.1 switchCRWT
49FanStatus fan speed1 Byte5.10 counter pulses (0..255)CRT
49Floor heating BON CMD for Night-mode1 Bit1.1 switchCRWT
50FanStatus fan On/Off1 Bit1.1 switchCRT
50Floor heating BON CMD for Away-mode1 Bit1.1 switchCRWT
51FanStatus fan speed automatic1 Bit1.3 enableCRT
51Floor heating BON CMD for Timer-mode1 Bit1.1 switchCRWT
52FanLimitation 11 Bit1.3 enableCRWT
52Floor heating BStatus value1 Bit1.1 switchCRT
53FanLimitation 21 Bit1.3 enableCRWT
53Floor heating BTrigger valve purge1 Bit1.17 triggerCW
54FanLimitation 31 Bit1.3 enableCRWT
54Floor heating BStatus valve purge1 Bit1.3 enableCRT
55FanLimitation 41 Bit1.3 enableCRWT
55Floor heating BStatus of base setpoint temp.2 Bytes9.1 temperature (°C)CRT
56Floor heating CActual temperature2 Bytes9.1 temperature (°C)CRWTU
56Floor heating CControl value C1 Byte5.1 percentage (0..100%)CWTU
57Floor heating CActual temp. error signal1 Bit1.5 alarmCRT
57Floor heating CControl value error signal1 Bit1.5 alarmCRT
58Floor heating CNormal-mode setpoint Temp.2 Bytes9.1 temperature (°C)CRWTU
59Floor heating CDay-mode setpoint Temp.2 Bytes9.1 temperature (°C)CRWTU
60Floor heating CNight-mode setpoint Temp.2 Bytes9.1 temperature (°C)CRWTU
61Valve Heating/CoolingStatus value1 Bit1.1 switchCRT
61Valve Heating/CoolingStatus value1 Byte5.1 percentage (0..100%)CRT
61Valve HeatingStatus value1 Bit1.1 switchCRT
61Valve HeatingStatus value1 Byte5.1 percentage (0..100%)CRT
61Floor heating CAway-mode setpoint Temp.2 Bytes9.1 temperature (°C)CRWTU
62Valve Heating/CoolingTrigger valve purge1 Bit1.17 triggerCW
62Valve HeatingTrigger valve purge1 Bit1.17 triggerCW
62Floor heating CPreset 1 Temp. for timer mode2 Bytes9.1 temperature (°C)CRWTU
62Valve HeatingTrigger valve purge1 Bit1.17 triggerCWU
63Valve Heating/CoolingStatus valve purge1 Bit1.3 enableCRT
63Valve HeatingStatus valve purge1 Bit1.3 enableCRT
63Floor heating CTime of day for preset 13 Bytes10.1 time of dayCRWT
64Floor heating CStart/Stop heating for preset11 Bit1.10 start/stopCRWT
64Valve HeatingValve open/close1 Bit1.9 open/closeCW
65Floor heating CPreset 2 Temp. for timer mode2 Bytes9.1 temperature (°C)CRWTU
66Valve CoolingStatus value1 Bit1.1 switchCRT
66Valve CoolingStatus value1 Byte5.1 percentage (0..100%)CRT
66Floor heating CTime of day for preset 23 Bytes10.1 time of dayCRWT
67Valve CoolingTrigger valve purge1 Bit1.17 triggerCW
67Floor heating CStart/Stop heating for preset21 Bit1.10 start/stopCRWT
68Valve CoolingStatus valve purge1 Bit1.3 enableCRT
68Floor heating CPreset 3 Temp. for timer mode2 Bytes9.1 temperature (°C)CRWTU
69Floor heating CTime of day for preset 33 Bytes10.1 time of dayCRWT
69Valve CoolingValve open/close1 Bit1.9 open/closeCW
70Floor heating CStart/Stop heating for preset31 Bit1.10 start/stopCRWT
71HVAC control modeStatus of control mode(byte)1 Byte20.105 HVAC control modeCRT
71Floor heating CFloor heating(1-ON,0-OFF)1 Bit1.1 switchCRWT
71Floor heating CFloor heating(1-ON,0-OFF)1 Bit1.1 switchCW
72HVAC control modeStatus of automatic mode1 Bit1.3 enableCRT
72Floor heating CON CMD for Normal-mode1 Bit1.1 switchCRWT
73HVAC control modeStatus of heating mode1 Bit1.3 enableCRT
73Floor heating CON CMD for Day-mode1 Bit1.1 switchCRWT
74HVAC control modeStatus of cooling mode1 Bit1.3 enableCRT
74Floor heating CON CMD for Night-mode1 Bit1.1 switchCRWT
75HVAC control modeStatus of off mode1 Bit1.3 enableCRT
75Floor heating CON CMD for Away-mode1 Bit1.1 switchCRWT
76HVAC control modeStatus of fan only mode1 Bit1.3 enableCRT
76Floor heating CON CMD for Timer-mode1 Bit1.1 switchCRWT
77Floor heating CStatus value1 Bit1.1 switchCRT
78Floor heating CTrigger valve purge1 Bit1.17 triggerCW
79Floor heating CStatus valve purge1 Bit1.3 enableCRT
80Floor heating CStatus of base setpoint temp.2 Bytes9.1 temperature (°C)CRT
81HVAC operation modeStatus of operation mode(byte)1 Byte20.102 HVAC modeCRT
81Floor heating DActual temperature2 Bytes9.1 temperature (°C)CRWTU
81Floor heating DControl value D1 Byte5.1 percentage (0..100%)CWTU
82HVAC operation modeStatus of comfort mode1 Bit1.1 switchCRT
82Floor heating DActual temp. error signal1 Bit1.5 alarmCRT
82Floor heating DControl value error signal1 Bit1.1 switchCRT
83HVAC operation modeStatus of standby mode1 Bit1.1 switchCRT
83Floor heating DNormal-mode setpoint Temp.2 Bytes9.1 temperature (°C)CRWTU
84HVAC operation modeStatus of economy mode1 Bit1.1 switchCRT
84Floor heating DDay-mode setpoint Temp.2 Bytes9.1 temperature (°C)CRWTU
85HVAC operation modeStatus of building protection1 Bit1.1 switchCRT
85Floor heating DNight-mode setpoint Temp.2 Bytes9.1 temperature (°C)CRWTU
86Floor heating DAway-mode setpoint Temp.2 Bytes9.1 temperature (°C)CRWTU
87Floor heating DPreset 1 Temp. for timer mode2 Bytes9.1 temperature (°C)CRWTU
88Floor heating DTime of day for preset 13 Bytes10.1 time of dayCRWT
89Floor heating DStart/Stop heating for preset11 Bit1.10 start/stopCRWT
90Floor heating DPreset 2 Temp. for timer mode2 Bytes9.1 temperature (°C)CRWTU
91SetpointStatus of base setpoint temp.2 Bytes9.1 temperature (°C)CRT
91Floor heating DTime of day for preset 23 Bytes10.1 time of dayCRWT
92Floor heating DStart/Stop heating for preset21 Bit1.10 start/stopCRWT
93Floor heating DPreset 3 Temp. for timer mode2 Bytes9.1 temperature (°C)CRWTU
94Floor heating DTime of day for preset 33 Bytes10.1 time of dayCRWT
95Floor heating DStart/Stop heating for preset31 Bit1.10 start/stopCRWT
96Floor heating DFloor heating(1-ON,0-OFF)1 Bit1.1 switchCRWT
96Floor heating DFloor heating(1-ON,0-OFF)1 Bit1.1 switchCW
97Floor heating DON CMD for Normal-mode1 Bit1.1 switchCRWT
98Floor heating DON CMD for Day-mode1 Bit1.1 switchCRWT
99Floor heating DON CMD for Night-mode1 Bit1.1 switchCRWT
100Floor heating DON CMD for Away-mode1 Bit1.1 switchCRWT
101Floor heating DON CMD for Timer-mode1 Bit1.1 switchCRWT
102Floor heating DStatus value1 Bit1.1 switchCRT
103Floor heating DTrigger valve purge1 Bit1.17 triggerCW
104Floor heating DStatus valve purge1 Bit1.3 enableCRT
105Floor heating DStatus of base setpoint temp.2 Bytes9.1 temperature (°C)CRT
106Floor heating EActual temperature2 Bytes9.1 temperature (°C)CRWTU
106Floor heating EControl value E1 Byte5.1 percentage (0..100%)CWTU
107Floor heating EActual temp. error signal1 Bit1.5 alarmCRT
107Floor heating EControl value error signal1 Bit1.5 alarmCRT
108Floor heating ENormal-mode setpoint Temp.2 Bytes9.1 temperature (°C)CRWTU
109Floor heating EDay-mode setpoint Temp.2 Bytes9.1 temperature (°C)CRWTU
110Floor heating ENight-mode setpoint Temp.2 Bytes9.1 temperature (°C)CRWTU
111Floor heating EAway-mode setpoint Temp.2 Bytes9.1 temperature (°C)CRWTU
112Floor heating EPreset 1 Temp. for timer mode2 Bytes9.1 temperature (°C)CRWTU
113Floor heating ETime of day for preset 13 Bytes10.1 time of dayCRWT
114Floor heating EStart/Stop heating for preset11 Bit1.10 start/stopCRWT
115Floor heating EPreset 2 Temp. for timer mode2 Bytes9.1 temperature (°C)CRWTU
116Floor heating ETime of day for preset 23 Bytes10.1 time of dayCRWT
117Floor heating EStart/Stop heating for preset21 Bit1.10 start/stopCRWT
118Floor heating EPreset 3 Temp. for timer mode2 Bytes9.1 temperature (°C)CRWTU
119Floor heating ETime of day for preset 33 Bytes10.1 time of dayCRWT
120Floor heating EStart/Stop heating for preset31 Bit1.10 start/stopCRWT
121Floor heating EFloor heating(1-ON,0-OFF)1 Bit1.1 switchCRWT
121Floor heating EFloor heating(1-ON,0-OFF)1 Bit1.1 switchCW
122Floor heating EON CMD for Normal-mode1 Bit1.1 switchCRWT
123Floor heating EON CMD for Day-mode1 Bit1.1 switchCRWT
124Floor heating EON CMD for Night-mode1 Bit1.1 switchCRWT
125Floor heating EON CMD for Away-mode1 Bit1.1 switchCRWT
126Floor heating EON CMD for Timer-mode1 Bit1.1 switchCRWT
127Floor heating EStatus value1 Bit1.1 switchCRT
128Floor heating ETrigger valve purge1 Bit1.17 triggerCW
129Floor heating EStatus valve purge1 Bit1.3 enableCRT
130Floor heating EStatus of base setpoint temp.2 Bytes9.1 temperature (°C)CRT
131Floor heating FActual temperature2 Bytes9.1 temperature (°C)CRWTU
131Floor heating FControl value F1 Byte5.1 percentage (0..100%)CWTU
132Floor heating FActual temp. error signal1 Bit1.5 alarmCRT
132Floor heating FControl value error signal1 Bit1.5 alarmCRT
133Floor heating FNormal-mode setpoint Temp.2 Bytes9.1 temperature (°C)CRWTU
134Floor heating FDay-mode setpoint Temp.2 Bytes9.1 temperature (°C)CRWTU
135Floor heating FNight-mode setpoint Temp.2 Bytes9.1 temperature (°C)CRWTU
136Floor heating FAway-mode setpoint Temp.2 Bytes9.1 temperature (°C)CRWTU
137Floor heating FPreset 1 Temp. for timer mode2 Bytes9.1 temperature (°C)CRWTU
138Floor heating FTime of day for preset 13 Bytes10.1 time of dayCRWT
139Floor heating FStart/Stop heating for preset11 Bit1.10 start/stopCRWT
140Floor heating FPreset 2 Temp. for timer mode2 Bytes9.1 temperature (°C)CRWTU
141Floor heating FTime of day for preset 23 Bytes10.1 time of dayCRWT
142Floor heating FStart/Stop heating for preset21 Bit1.10 start/stopCRWT
143Floor heating FPreset 3 Temp. for timer mode2 Bytes9.1 temperature (°C)CRWTU
144Floor heating FTime of day for preset 33 Bytes10.1 time of dayCRWT
145Floor heating FStart/Stop heating for preset31 Bit1.10 start/stopCRWT
146Floor heating FFloor heating(1-ON,0-OFF)1 Bit1.1 switchCRWT
146Floor heating FFloor heating(1-ON,0-OFF)1 Bit1.1 switchCW
147Floor heating FON CMD for Normal-mode1 Bit1.1 switchCRWT
148Floor heating FON CMD for Day-mode1 Bit1.1 switchCRWT
149Floor heating FON CMD for Night-mode1 Bit1.1 switchCRWT
150Floor heating FON CMD for Away-mode1 Bit1.1 switchCRWT
151Floor heating FON CMD for Timer-mode1 Bit1.1 switchCRWT
152Floor heating FStatus value1 Bit1.1 switchCRT
152Floor heating FStatus value1 Byte5.1 percentage (0..100%)CRT
153Floor heating FTrigger valve purge1 Bit1.17 triggerCW
154Floor heating FStatus valve purge1 Bit1.3 enableCRT
155Floor heating FStatus of base setpoint temp.2 Bytes9.1 temperature (°C)CRT
156Floor heating GActual temperature2 Bytes9.1 temperature (°C)CRWTU
156Floor heating GControl value G1 Byte5.1 percentage (0..100%)CWTU
157Floor heating GActual temp. error signal1 Bit1.5 alarmCRT
157Floor heating GControl value error signal1 Bit1.5 alarmCRT
158Floor heating GNormal-mode setpoint Temp.2 Bytes9.1 temperature (°C)CRWTU
159Floor heating GDay-mode setpoint Temp.2 Bytes9.1 temperature (°C)CRWTU
160Floor heating GNight-mode setpoint Temp.2 Bytes9.1 temperature (°C)CRWTU
161Floor heating GAway-mode setpoint Temp.2 Bytes9.1 temperature (°C)CRWTU
162Floor heating GPreset 1 Temp. for timer mode2 Bytes9.1 temperature (°C)CRWTU
163Floor heating GTime of day for preset 13 Bytes10.1 time of dayCRWT
164Floor heating GStart/Stop heating for preset11 Bit1.10 start/stopCRWT
165Floor heating GPreset 2 Temp. for timer mode2 Bytes9.1 temperature (°C)CRWTU
166Floor heating GTime of day for preset 23 Bytes10.1 time of dayCRWT
167Floor heating GStart/Stop heating for preset21 Bit1.10 start/stopCRWT
168Floor heating GPreset 3 Temp. for timer mode2 Bytes9.1 temperature (°C)CRWTU
169Floor heating GTime of day for preset 33 Bytes10.1 time of dayCRWT
170Floor heating GStart/Stop heating for preset31 Bit1.10 start/stopCRWT
171Floor heating GFloor heating(1-ON,0-OFF)1 Bit1.1 switchCRWT
171Floor heating GFloor heating(1-ON,0-OFF)1 Bit1.1 switchCW
172Floor heating GON CMD for Normal-mode1 Bit1.1 switchCRWT
173Floor heating GON CMD for Day-mode1 Bit1.1 switchCRWT
174Floor heating GON CMD for Night-mode1 Bit1.1 switchCRWT
175Floor heating GON CMD for Away-mode1 Bit1.1 switchCRWT
176Floor heating GON CMD for Timer-mode1 Bit1.1 switchCRWT
177Floor heating GStatus value1 Bit1.1 switchCRT
177Floor heating GStatus value1 Byte5.1 percentage (0..100%)CRT
178Floor heating GTrigger valve purge1 Bit1.17 triggerCW
179Floor heating GStatus valve purge1 Bit1.3 enableCRT
180Floor heating GStatus of base setpoint temp.2 Bytes9.1 temperature (°C)CRT
181Output AChannel output1 Bit1.1 switchCW
181Floor heating AStatus of working(1-ON,0-OFF)1 Bit1.1 switchCRT
182Output AAlways response switch state1 Bit1.1 switchCRT
182Output AResponse state after change1 Bit1.1 switchCRT
182Floor heating AStatus of Normal-mode1 Bit1.1 switchCRT
183Output ARead statistic for hours2 Bytes7.7 time (h)CRT
183Floor heating AStatus of Day-mode1 Bit1.1 switchCRT
184Output AAlarm statistic for time out1 Bit1.5 alarmCRT
184Floor heating AStatus of Night-mode1 Bit1.1 switchCRT
185Output AStaircase light1 Bit1.1 switchCW
185Floor heating AStatus of Away-mode1 Bit1.1 switchCRT
186Output AChange staircase lighting time2 Bytes7.5 time (s)CW
186Floor heating AStatus of Timer-mode1 Bit1.1 switchCRT
187Output AAlarm staircase lighting1 Bit1.5 alarmCRT
188Relay AR/W statistic for counter4 Bytes12.1 counter pulses (unsigned)CRWT
189Output AWrite statistic for hours2 Bytes7.7 time (h)CW
190Output AR/W statistic for seconds4 Bytes13.100 time lag (s)CRWT
191Output BChannel output1 Bit1.1 switchCW
191Floor heating BStatus of working(1-ON,0-OFF)1 Bit1.1 switchCRT
192Output BAlways response switch state1 Bit1.1 switchCRT
192Output BResponse state after change1 Bit1.1 switchCRT
192Floor heating BStatus of Normal-mode1 Bit1.1 switchCRT
193Output BRead statistic for hours2 Bytes7.7 time (h)CRT
193Floor heating BStatus of Day-mode1 Bit1.1 switchCRT
194Output BAlarm statistic for time out1 Bit1.5 alarmCRT
194Floor heating BStatus of Night-mode1 Bit1.1 switchCRT
195Output BStaircase light1 Bit1.1 switchCW
195Floor heating BStatus of Away-mode1 Bit1.1 switchCRT
196Output BChange staircase lighting time2 Bytes7.5 time (s)CW
196Floor heating BStatus of Timer-mode1 Bit1.1 switchCRT
197Output BAlarm staircase lighting1 Bit1.5 alarmCRT
198Relay BR/W statistic for counter4 Bytes12.1 counter pulses (unsigned)CRWT
199Output BWrite statistic for hours2 Bytes7.7 time (h)CW
200Output BR/W statistic for seconds4 Bytes13.100 time lag (s)CRWT
201Output CChannel output1 Bit1.1 switchCW
201Floor heating CStatus of working(1-ON,0-OFF)1 Bit1.1 switchCRT
202Output CAlways response switch state1 Bit1.1 switchCRT
202Output CResponse state after change1 Bit1.1 switchCRT
202Floor heating CStatus of Normal-mode1 Bit1.1 switchCRT
203Output CRead statistic for hours2 Bytes7.7 time (h)CRT
203Floor heating CStatus of Day-mode1 Bit1.1 switchCRT
204Output CAlarm statistic for time out1 Bit1.5 alarmCRT
204Floor heating CStatus of Night-mode1 Bit1.1 switchCRT
205Output CStaircase light1 Bit1.1 switchCW
205Floor heating CStatus of Away-mode1 Bit1.1 switchCRT
206Output CChange staircase lighting time2 Bytes7.5 time (s)CW
206Floor heating CStatus of Timer-mode1 Bit1.1 switchCRT
207Output CAlarm staircase lighting1 Bit1.5 alarmCRT
208Relay CR/W statistic for counter4 Bytes12.1 counter pulses (unsigned)CRWT
209Output CWrite statistic for hours2 Bytes7.7 time (h)CW
210Output CR/W statistic for seconds4 Bytes13.100 time lag (s)CRWT
211Output DChannel output1 Bit1.1 switchCW
211Floor heating DStatus of working(1-ON,0-OFF)1 Bit1.1 switchCRT
212Output DAlways response switch state1 Bit1.1 switchCRT
212Output DResponse state after change1 Bit1.1 switchCRT
212Floor heating DStatus of Normal-mode1 Bit1.1 switchCRT
213Output DRead statistic for hours2 Bytes7.7 time (h)CRT
213Floor heating DStatus of Day-mode1 Bit1.1 switchCRT
214Output DAlarm statistic for time out1 Bit1.5 alarmCRT
214Floor heating DStatus of Night-mode1 Bit1.1 switchCRT
215Output DStaircase light1 Bit1.1 switchCW
215Floor heating DStatus of Away-mode1 Bit1.1 switchCRT
216Output DChange staircase lighting time2 Bytes7.5 time (s)CW
216Floor heating DStatus of Timer-mode1 Bit1.1 switchCRT
217Output DAlarm staircase lighting1 Bit1.5 alarmCRT
218Relay DR/W statistic for counter4 Bytes12.1 counter pulses (unsigned)CRWT
219Output DWrite statistic for hours2 Bytes7.7 time (h)CW
220Output DR/W statistic for seconds4 Bytes13.100 time lag (s)CRWT
221Output EChannel output1 Bit1.1 switchCW
221Floor heating EStatus of working(1-ON,0-OFF)1 Bit1.1 switchCRT
222Output EAlways response switch state1 Bit1.1 switchCRT
222Output EResponse state after change1 Bit1.1 switchCRT
222Floor heating EStatus of Normal-mode1 Bit1.1 switchCRT
223Output ERead statistic for hours2 Bytes7.7 time (h)CRT
223Floor heating EStatus of Day-mode1 Bit1.1 switchCRT
224Output EAlarm statistic for time out1 Bit1.5 alarmCRT
224Floor heating EStatus of Night-mode1 Bit1.1 switchCRT
225Output EStaircase light1 Bit1.1 switchCW
225Floor heating EStatus of Away-mode1 Bit1.1 switchCRT
226Output EChange staircase lighting time2 Bytes7.5 time (s)CW
226Floor heating EStatus of Timer-mode1 Bit1.1 switchCRT
227Output EAlarm staircase lighting1 Bit1.5 alarmCRT
228Relay ER/W statistic for counter4 Bytes12.1 counter pulses (unsigned)CRWT
229Output EWrite statistic for hours2 Bytes7.7 time (h)CW
230Output ER/W statistic for seconds4 Bytes13.100 time lag (s)CRWT
231Floor heating FStatus of working(1-ON,0-OFF)1 Bit1.1 switchCRT
232Floor heating FStatus of Normal-mode1 Bit1.1 switchCRT
233Floor heating FStatus of Day-mode1 Bit1.1 switchCRT
234Floor heating FStatus of Night-mode1 Bit1.1 switchCRT
235Floor heating FStatus of Away-mode1 Bit1.1 switchCRT
236Floor heating FStatus of Timer-mode1 Bit1.1 switchCRT
237Null Anull1 BitCRWTU
238Null Anull1 BitCRWTU
239Null Anull1 BitCRWTU
240Null Anull1 BitCRWTU
241Floor heating GStatus of working(1-ON,0-OFF)1 Bit1.1 switchCRT
242Floor heating GStatus of Normal-mode1 Bit1.1 switchCRT
243Floor heating GStatus of Day-mode1 Bit1.1 switchCRT
244Floor heating GStatus of Night-mode1 Bit1.1 switchCRT
245Floor heating GStatus of Away-mode1 Bit1.1 switchCRT
246Floor heating GStatus of Timer-mode1 Bit1.1 switchCRT
247Null Anull1 BitCRWTU
248Null Anull1 BitCRWTU
249Null Anull1 BitCRWTU
250Null Anull1 BitCRWTU
251Null Anull1 BitCRWTU
252Null Anull1 BitCRWTU
253Null Anull1 BitCRWTU
254Null Anull1 BitCRWTU
Parameters (242)
ParameterTypeDefault
System delay (3..100s)unsignedInt 3…1005
Heartbeat telegram (1..65535s , 0-invalid)unsignedInt 0…655350
Passive controllistDisable
Supported functionlistFan coil unite
HVAC passive control systemlist1 Control value/2-pipe
-->Switch object configurationlist1-heat valve,0-cool valve
-->Switch object configurationlist1-A,0-B
Heating/Cooling channel selectlistChannel E (relay)
Fan channel selectlistChannel A-C (relay)
Heating channel selectlistChannel E (relay)
Cooling channel selectlistChannel D (relay)
Enable set default control value after system restart workinglistDisable
-->Default control value(0..100%)unsignedInt 0…1000
Heating and cooling channels are mutually exclusivelistEnable
System ON/OFF on bus voltage recoverylistOFF
Supported functionslistHeating and Cooling
HVAC-Systemlist2-pipe system
Heating channel was off,delay off fan (0..255s)unsignedInt 0…2550
Cooling channel was off,delay off fan (0..255s)unsignedInt 0…2550
Heating/cooling channel was off,delay off fan (0..255s)unsignedInt 0…2550
Fan was off,off heating channellistDisable
Fan was off,off cooling channellistDisable
Fan was off,off heating/cooling channellistDisable
Heating speed (for PI)listMedium
Cooling speed (for PI)listMedium
Enable slave clocklistEnable
Temperature gettinglistLocal sensor averagely(Max.7)
Temperature measure interval (3..100 s)unsignedInt 3…10010
Temperature 1 serial number (1..255)unsignedInt 1…2551
Temperature 1 correction value (-5..5 'C)list0.0
Send temperature 1 cyclicallylistNo
-->Cycle time (1..255 s)unsignedInt 1…25510
Send temperature 1 after a change('C)list1.0
Enable Temperature 2listNo
-Temperature 2 serial number (1..255)unsignedInt 1…2552
Temperature 2 correction value (-5..5 'C)list0.0
-Temperature 2 correction value (-5..5 'C)list0.0
-Send temperature 2 cyclicallylistNo
-Send temperature 2 after a change('C)list1.0
Enable Temperature 3listNo
-Temperature 3 serial number (1..255)unsignedInt 1…2553
-Temperature 3 correction value (-5..5 'C)list0.0
-Send temperature 3 cyclicallylistNo
-Send temperature 3 after a change('C)list1.0
Enable Temperature 4listNo
-Temperature 4 serial number (1..255)unsignedInt 1…2554
-Temperature 4 correction value (-5..5 'C)list0.0
-Send temperature 4 cyclicallylistNo
-Send temperature 4 after a change('C)list1.0
Read temperature cyclically via EIBlistNo
Period of temperature monitoring (2..255 min)unsignedInt 2…2552
Number of times sending error signal (1..255,0-Unlimited)unsignedInt 0…2550
Base setpoint temperature (10..35 'C)unsignedInt 10…3525
Setpoint temperature value per steplist0.5 'C
Operation mode at power onlistComfort mode
Conrtol mode at power onlistUnchanged
Energy saving functionlistDisable
-->Delay time (1..65535 min)unsignedInt 1…6553560
-->Change delay time via buslistNo
-->Comfort mode tolistEconomy mode
-->Chang Energy mode via buslistNo
Reduced setpoint in standby mode (0..10 'C)unsignedInt 0…102
Reduced setpoint in economy mode (0..10 'C)unsignedInt 0…104
Temperature in frost protection mode (2..10 'C)unsignedInt 2…107
Maximum setpoint temperature (5..45 'C)unsignedInt 5…4535
Automatically switch to building protection modelistDisable
Increased setpoint in standby mode (0..10 'C)unsignedInt 0…102
Increased setpoint in economy mode (0..10 'C)unsignedInt 0…104
Temperature in heat protection mode (35..40 'C)unsignedInt 35…4040
Minimum setpoint temperature (5..45 'C)unsignedInt 5…4515
Heating modelist'1'
Cooling modelist'1'
Fan only modelist'1'
Off modelist'1'
Comfort modelist'1'
Standby modelist'1'
Economy modelist'1'
Protection modelist'1'
Types of controllistTwo-step (ON/OFF) control
Valve typelistNormal(de-energized closed)
Reaction on bus voltage failurelistContact open
PWM Cycle time (1..30 min)unsignedInt 1…303
Minimum heating/coolinglist0%
Enable valve purgelistNo
-->Time of valve purge (1..255 min)unsignedInt 1…2555
-->Automatic valve purgelistNo
Types of controllistContinuous-action control
Valve adjustmentlistDisable
-->Lower limit for active valve opening range (0..100%)unsignedInt 0…1000
-->Upper limit for active valve opening range (0..100%)unsignedInt 0…100100
Heating/Cooling valve statuslistNo
-->Send object valuelistOnly after change
-->Type of status reportlistReport position,ON/OFF
-->Object value with PWM >0list'1'
-->Deviation for sending position(0..50%)unsignedInt 0…505
Control mode status (1bit)listNo
-->Object sending rangelistOnly activated status object
-->Object value with ON statuslist'1'
Control mode status (1byte)listNo
Operation mode status (1bit)listNo
Operation mode status (1byte)listNo
Base setpoint temp. status (2byte)listNo
Enable switch actuatorlistInactive
Object value for switching onlist'1'
Response of switch state ON/OFFlistNo response
Save statistic for ON switching timelistDisable
-->Alarm when time out (1..65535h,0-invalid)unsignedInt 0…6553530000
-->Transmit telegram interval when alarm(1..255s)unsignedInt 1…25510
Switch state on bus voltage faillistUnchanged
Switch state after bus voltage recoverylistUnchanged
Time functionlistDisable
-->Control staircase lightinglistStart with '1'/'0',Can't Stop
-->Change staircase lighting time via buslistYes
-->Alarm staircase lighting to buslistYes
-->Time for off :(0..255 Min)unsignedInt 0…2550
-->Time for off :(0..59 Sec)unsignedInt 0…595
-->Warning staircase lighting (ON->OFF->ON)listNo
---Warning before the end of time (sec)unsignedInt 3…1003
---Duration time for warning (sec)unsignedInt 1…101
-->Delay for switching ON:(0..255 Min)unsignedInt 0…2550
-->Delay for switching ON:(0..59 Sec)unsignedInt 0…590
-->Delay for switching OFF:(0..255 Min)unsignedInt 0…2550
-->Delay for switching OFF:(0..59 Sec)unsignedInt 0…590
Fan speed relay outputlist3-Speed fan
Fan control typelistChangeover switch
Fan control encoded modelistEncoded by 1 byte percent value 0-100%
-->Fan speed-1 value(0..255)unsignedInt 0…255255
-->Fan speed-2 value(0..255)unsignedInt 0…255255
-->Fan speed-3 value(0..255)unsignedInt 0…255255
Fan speed on bus voltage failurelistOFF
Fan speed on bus voltage recoverylistRecovery
Fan switch-on delay (0..255 s)unsignedInt 0…2550
Fan switch-off delay (0..255 s)unsignedInt 0…2550
Enable start-up behaviorlistDisable
->Starting characteristic of fanlistSwitch on at speed 2
->Minimum delay at starting speed (2..255 s)unsignedInt 2…2555
Changeover delay between fan speeds (s)list0.5
Minimum duartion time on fan speed (2..255 s)unsignedInt 2…2555
->Starting characteristic of fanlistSwitch on at speed 3
Fan automatic controllist'1'
Enable limitationslistDisable
-->Speed with limitation 1listunchanged
-->Speed with limitation 2listunchanged
-->Speed with limitation 3listunchanged
-->Speed with limitation 4listunchanged
Over setpoint temperature(Auto control)listOn speed 1
Fan speed x status (1bit)listNo
-->MeaninglistRequired fan speed
-->Valid object valuelist'1'
Fan speed status (1byte)listNo
-->1 Byte value encode modelistEncoded by 1 byte constant value 0-3
Fan On/Off status (1bit)listNo
Fan speed automatic status (1bit)listNo
-->Object value with valve position >0list'1'
-->Fan speed-1 value(0..255)unsignedInt 0…25585
-->Fan speed-2 value(0..255)unsignedInt 0…255170
Fan speed 1 voltage (0-10V)list3V
Fan speed 2 voltage (0-10V)list5V
Fan speed 3 voltage (0-10V)list10V
Changeover delay between fan speeds (s)list0.0
Insensitive zone between heating and cooling (1..10 'C)unsignedInt 1…101
Auto modelist'1'
Minimum heatinglist0%
Minimum coolinglist0%
Heating valve statuslistNo
Cooling valve statuslistNo
Channel A work modelistFloor heating
-->Change staircase lighting time via buslistNo
Temperature gettinglistLocal sensor
Temperature sensor serial number (1..255)unsignedInt 1…2551
Temperature correction value (-5..5 'C)list0.0
Cyclical sendinglistNo
-->Period for cyclical sending (1..255 s)unsignedInt 1…25510
Differential value for sending ('C)list1.0
-->Period for cyclical reading (1..255 s)unsignedInt 1…2552
The operation mode after bus voltage recoverylistRecovery
Floor heating speed (for PI)listMedium
Normal mode setpoint temperature (5..120 'C)unsignedInt 5…12025
Day mode setpoint temperature (5..120 'C)unsignedInt 5…12023
Night mode setpoint temperature (5..120 'C)unsignedInt 5…12020
Away mode setpoint temperature (5..120 'C)unsignedInt 5…12015
Enable send operating statuslistDisable
-->Preset 1 temperature (5..120 'C)unsignedInt 5…12025
---Start/Stop the floor heatinglistStart
---Start time for hour (0..23 h)list00
---Start time for minute (0..59 min)list00
-->Preset 2 temperature (5..120 'C)unsignedInt 5…12023
---Start time for hour (0..23 h)list06
-->Preset 3 temperature (5..120 'C)unsignedInt 5…12020
---Start time for hour (0..23 h)list17
Normal modelist'1'
Day modelist'1'
Night modelist'1'
Away modelist'1'
Types of controllistPWM control
Enable pipe pressure protection when all of floor heating OFFlistNo
-->Valve open valuelist5%
-->Protection time (1..255min,0-Unlimited)unsignedInt 0…25560
Channel B work modelistInactive
-->Delay for switching ON:(0..255 Min)unsignedInt 0…255255
Temperature sensor serial number (1..255)unsignedInt 1…2552
Away mode setpoint temperature (5..120 'C)unsignedInt 5…12015
-->Preset 1 temperature (5..120 'C)unsignedInt 5…12025
-->Preset 3 temperature (5..120 'C)unsignedInt 5…12020
Channel C work modelistInactive
Temperature sensor serial number (1..255)unsignedInt 1…2553
-->Preset 2 temperature (5..120 'C)unsignedInt 5…12023
Channel D work modelistInactive
Temperature sensor serial number (1..255)unsignedInt 1…2554
Normal mode setpoint temperature (5..120 'C)unsignedInt 5…12025
Day mode setpoint temperature (5..120 'C)unsignedInt 5…12023
Night mode setpoint temperature (5..120 'C)unsignedInt 5…12020
Channel E work modelistInactive
-->Alarm staircase lighting to buslistNo
Temperature sensor serial number (1..255)unsignedInt 1…2555
Read temperature cyclically via EIBlistYes
Channel F work modelistInactive
Temperature sensor serial number (1..255)unsignedInt 1…2556
Enable pipe pressure protection when all of floor heating OFFlistYes
Channel G work modelistInactive
Temperature sensor serial number (1..255)unsignedInt 1…2557
Enable monitoring control valuelistDisable
->Monitoring interval[2..255min]unsignedInt 2…2552
->Send object value'Control value error signal'listOnly after change
->Set control value during faultlistDisable
->Control value default[0..100%]unsignedInt 0…10010
Enable control heating/cooling valve directlylistNo
Threshold for fan speed 1 (1..100 %)unsignedInt 1…10030
Threshold for fan speed 2 (1..100 %)unsignedInt 1…10060
Threshold for fan speed 3 (1..100 %)unsignedInt 1…10090
Hysteresis for fan speed (0..10 %)unsignedInt 0…105
Enable control heating valve directlylistNo
Enable control cooling valve directlylistNo
Enable valve purgelistDisable
Enable pipe pressure protection when all of floor heating OFFlistDisable
Enable monitoring control value AlistDisable
Enable monitoring control value BlistDisable
Enable monitoring control value ClistDisable
Enable monitoring control value DlistDisable
Enable monitoring control value ElistDisable
Enable monitoring control value FlistDisable
Enable monitoring control value GlistDisable

Version history

ApplicationApp noFingerprintFirst seenSizeFile
FCU & Floor Heating Actuator(V2.0) 2.0 latest$224061172026-11-25376 KBDownload

About this file

This is the official ETS product database for the HDL M/FCU01.10.1 (M/FCU01 1206 F001), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.