Impuls gateway KNX ETS 2 inputs TYC702E
Hager Electro · Order number TYC702E · Meter › Pulse meter
TYC702E
Download .knxprod STYC702E 1.0 · 71 KB
Product
| Manufacturer | Hager Electro |
|---|---|
| Product name | Impuls gateway KNX ETS 2 inputs |
| Order number | TYC702E |
| Product text | Passerelle 2 entrées impulsions |
| Hardware | TYC702E |
| Medium | Twisted Pair |
| Bus current (mA) | 10 |
| Rail mounted | No |
| Registration | Registered |
| Languages | fr-FR, de-DE, en-US |
| Catalog entry | M-0009_H-9.20.2F.2F.20TYC702E-0-O0076_HP-5003-10-BAAA-O0076_CI-TYC702E-1 |
| Fingerprint | BAAA |
| SHA-256 | 2d0d0684f52c28b47b8202d06204cc7dabff65ed60cfb2bd487b1193172775e1 |
| First seen | 2026-11-25 |
| Markets | 69 markets |
Application program: STYC702E 1.0
| Application number | $5003 |
|---|---|
| Version | 1.0 |
| Mask version | MV-0701 (7.1) |
| KNX Data Secure | No |
| Minimum ETS version | 3.0f |
| Parameters | 40 |
| Group objects | 48 |
Group objects (48)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Débit voie 1 | Valeur calculée | 4 Bytes | 14.77 volume flux (m³/s) | CRT |
| 0 | Puissance voie 1 | Valeur calculée | 4 Bytes | 14.56 power (W) | CRT |
| 0 | Puissance | Valeur calculée | 4 Bytes | 14.56 power (W) | CRT |
| 1 | Volume total voie 1 | Valeur comptée | 4 Bytes | 14.76 volume (m³) | CRT |
| 1 | Total volume scale 1 | Valeur comptée | 4 Bytes | 14.76 volume (m³) | CRT |
| 1 | Energie totale voie 1 | Valeur comptée | 4 Bytes | DPT.13 | CRT |
| 1 | Total energy scale 1 | Valeur comptée | 4 Bytes | DPT.13 | CRT |
| 2 | Reference volume scale 1 | Consumption Last Due Date | 4 Bytes | 14.76 volume (m³) | CRT |
| 2 | Reference energy channel 1 | Consumption Last Due Date | 4 Bytes | DPT.13 | CRT |
| 2 | Reference energy scale 1 | Consumption Last Due Date | 4 Bytes | DPT.13 | CRT |
| 3 | Volume partiel voie 1 | Valeur partielle | 4 Bytes | 14.76 volume (m³) | CRT |
| 3 | Partial volume scale 1 | Consumption Value | 4 Bytes | 14.76 volume (m³) | CRT |
| 3 | Energie partielle voie 1 | Valeur partielle | 4 Bytes | DPT.13 | CRT |
| 3 | Partial energy scale 1 | Consumption Value | 4 Bytes | DPT.13 | CRT |
| 4 | Reset compteur partiel voie 1 | Consumption Reset | 2 Bytes | 7.1 pulses | CWU |
| 4 | Partial reset scale 1 | Consumption Reset | 2 Bytes | 7.1 pulses | CWU |
| 4 | Reset compteur partiel voie 1 | Reset compteur partiel | 1 Bit | DPT.1 | CWU |
| 4 | Partial reset scale 1 | Consumption Reset | 1 Bit | DPT.1 | CWU |
| 5 | Partial reset date channel 1 | Consumption Reset | 3 Bytes | 11.1 date | CRT |
| 6 | Partial reset time channel 1 | Consumption Reset | 3 Bytes | 10.1 time of day | CRT |
| 7 | Serialnumber | Serialnumber | 14 Bytes | 16.0 Character String (ASCII) | CRT |
| 8 | Limit alarm scale 1 | Limit | 1 Bit | DPT.1 | CRWU |
| 9 | Débit voie 2 | Valeur calculée | 4 Bytes | 14.77 volume flux (m³/s) | CRT |
| 9 | Puissance voie 2 | Valeur calculée | 4 Bytes | 14.56 power (W) | CRT |
| 10 | Volume total voie 2 | Valeur comptée | 4 Bytes | 14.76 volume (m³) | CRT |
| 10 | Total volume scale 2 | Valeur comptée | 4 Bytes | 14.76 volume (m³) | CRT |
| 10 | Energie totale voie 2 | Valeur comptée | 4 Bytes | DPT.13 | CRT |
| 10 | Total energy scale 2 | Valeur comptée | 4 Bytes | DPT.13 | CRT |
| 11 | Reference volume channel 2 | Consumption Last Due Date | 4 Bytes | 14.76 volume (m³) | CRT |
| 11 | Reference volume scale 2 | Consumption Last Due Date | 4 Bytes | 14.76 volume (m³) | CRT |
| 11 | Reference energy scale 2 | Consumption Last Due Date | 4 Bytes | DPT.13 | CRT |
| 12 | Volume partiel voie 2 | Valeur partielle | 4 Bytes | 14.76 volume (m³) | CRT |
| 12 | Partial volume scale 2 | Consumption Value | 4 Bytes | 14.76 volume (m³) | CRT |
| 12 | Energie partielle voie 1 | Valeur partielle | 4 Bytes | DPT.13 | CRT |
| 12 | Partial energy scale 2 | Consumption Value | 4 Bytes | DPT.13 | CRT |
| 13 | Reset compteur partiel voie 2 | Consumption Reset | 2 Bytes | 7.1 pulses | CWU |
| 13 | Partial reset scale 2 | Consumption Reset | 2 Bytes | 7.1 pulses | CWU |
| 13 | Reset compteur partiel voie 2 | Reset compteur partiel | 1 Bit | DPT.1 | CWU |
| 13 | Partial reset scale 2 | Consumption Reset | 1 Bit | DPT.1 | CWU |
| 14 | Partial reset date scale 2 | Consumption Reset | 3 Bytes | 11.1 date | CRT |
| 15 | Partial reset time scale 2 | Consumption Reset | 3 Bytes | 10.1 time of day | CRT |
| 16 | Selected scale | Scale | 1 Bit | 1.1 switch | CRT |
| 17 | Limit alarm channel 2 | Limit | 1 Bit | DPT.1 | CRWU |
| 18 | Current date | Real Time Clock | 3 Bytes | 11.1 date | CRWTU |
| 19 | Current time | Real Time Clock | 3 Bytes | 10.1 time of day | CRWTU |
| 20 | Last reference date | Due Date | 3 Bytes | 11.1 date | CRT |
| 21 | Next reference date | Due Date | 3 Bytes | 11.1 date | CRWTU |
| 22 | Alarm profile | Limit Selection | 1 Bit | 1.1 switch | CRWU |
Parameters (35)
| Parameter | Type | Default |
|---|---|---|
| Use Daylight Saving Time | list | Yes |
| Hager | list | Yes |
| Type of Counter | list | 2 Independent Counters |
| Channel 1 Datatype | list | Float |
| Channel 2 Datatype | list | Float |
| Use PIN for Reset? | list | No |
| Reset PIN ohne | unsignedInt 0…0 | 0 |
| Reset PIN | unsignedInt 1…65535 | 1 |
| Use PIN for Reset? | list | Yes |
| Comportement compteur en absence d'impulsion | list | Pas d'émission |
| Use Limit Profile | list | No |
| Comptage | list | Compteur de volume (m3) |
| Emission cyclique | list | Inactif |
| Nombre d'impulsions | unsignedInt 0…99 | 10 |
| Facteur de multiplication | list | * 1 |
| Preset valeur de comptage | unsignedInt 0…4294967295 | 0 |
| Flow Measurement Period | list | Per Second |
| Use of Limit 1 | list | Value Limit |
| Limit 1 | unsignedInt 0…99 | 0 |
| Use of Limit 2 | list | Value Limit |
| Limit 2 | unsignedInt 0…99 | 0 |
| Preset Counter Value Scale 1 [ 0 - no changes ] | unsignedInt 0…4294967295 | 0 |
| Preset Counter Value Scale 2 [ 0 - no changes ] | unsignedInt 0…4294967295 | 0 |
| Use of Limit 1 Scale 1 | list | Value Limit |
| Limit 1 Scale 1 | unsignedInt 0…99 | 0 |
| Limit 1 Scale 1 Exponent | list | * 1 |
| Use of Limit 2 Scale 1 | list | Value Limit |
| Limit 2 Scale 1 | unsignedInt 0…99 | 0 |
| Limit 2 Scale 1 Exponent | list | * 1 |
| Use of Limit 1 Scale 2 | list | Value Limit |
| Limit 1 Scale 2 | unsignedInt 0…99 | 0 |
| Limit 1 Scale 2 Exponent | list | * 1 |
| Use of Limit 2 Scale 2 | list | Value Limit |
| Limit 2 Scale 2 | unsignedInt 0…99 | 0 |
| Limit 2 Scale 2 Exponent | list | * 1 |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| STYC702E 1.0 latest | $5003 | BAAA | 2026-11-25 | 71 KB | Download |
About this file
This is the official ETS product database for the Hager Electro Impuls gateway KNX ETS 2 inputs (TYC702E), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from Hager Electro
- Consumption indicator TE330
- Consumption indicator TE331
- Energy meter - Direct 100A TE360
- Energy meter - Via current transformer TE370
- KNX pulse gateway 1 channel TXE771
- KNX pulse gateway 3 channels TXE773
- KNX Interface for energy meters TXF121
- Impuls gateway KNX ETS 1 input TYC701E
- Dummy device Dummy
- EHZ energy data sender EHZ503
- TCB602B/TCB603B(2/3-fold switch actuator 10A 230V) TCB603B
- Hager Electro/lighting/Dimmer TCB662E