KNX Database

KNX pulse gateway 1 channel TXE771

Hager Electro · Order number TXE771 · Meter › Pulse meter

Download .knxprod STXE771 1.0 · 89 KB

Product

ManufacturerHager Electro
Product nameKNX pulse gateway 1 channel
Order numberTXE771
HardwareTXE771
MediumTwisted Pair
Bus current (mA)7
Rail mountedNo
RegistrationRegistered · 2016-10-05
Languagesfr-FR, de-DE, en-US, es-ES, it-IT, nl-NL, pt-PT, nb-NO, sv-SE
Catalog entryM-0009_H-9.20.2F.2F.20TXE771-1_HP-E0BF-10-BA36_CI-TXE771-1
FingerprintBA36
SHA-256dbc9b925e0756ca9321d6b17aedd6a344a16bfbe2720602c591cec3c214658d0
First seen2026-11-25
Markets69 markets

Application program: STXE771 1.0

Application number$E0BF
Version1.0
Mask versionMV-0701 (7.1)
KNX Data SecureNo
Minimum ETS version4.0
Parameters81
Group objects32
Group objects (32)
NoNameFunctionSizeDPTFlags
0Input 1Total energy timestamped14 BytesCRTU
1Input 1Partial energy timestamped14 BytesCRTU
2Input 1Total energy timestamped12 BytesCRTU
3Input 1Partial energy timestamped12 BytesCRTU
4Input 1Total volume timestamped12 BytesCRTU
5Input 1Partial volume timestamped12 BytesCRTU
6Input 1Power timestamped12 BytesCRTU
7Input 1Flow rate timestamped12 BytesCRTU
8Input 1Total energy6 BytesCRTU
9Input 1Partial energy6 BytesCRTU
10Input 1Total energy4 Bytes13.10 active energy (Wh)CRTU
11Input 1Partial energy4 Bytes13.10 active energy (Wh)CRTU
12Input 1Total volume4 Bytes14.76 volume (m³)CRTU
13Input 1Partial volume4 Bytes14.76 volume (m³)CRTU
14Input 1Power4 Bytes14.56 power (W)CRTU
15Input 1Flow rate4 Bytes14.77 volume flux (m³/s)CRTU
16Input 1Pulse1 Bit1.2 booleanCRTU
17Input 1Partial meter reset activation1 Bit1.15 resetCRW
18Input 1Dynamic mode activation1 Bit1.3 enableCRW
19Input 1Set total energy6 BytesCRW
20Input 1Set total energy4 Bytes13.10 active energy (Wh)CRW
21Input 1Set total volume4 Bytes14.76 volume (m³)CRW
22Input 1History request1 Bit1.10 start/stopCRW
23Date and timeDate3 Bytes11.1 dateCRW
24Date and timeTime3 Bytes10.1 time of dayCRW
25Date and timeDate and time8 Bytes19.1 date timeCRW
26Date and timeDate and time request1 Bit1.10 start/stopCRTU
27TariffCurrent tariff request1 Bit1.10 start/stopCRTU
28TariffCurrent tariff1 Byte5.6 tariff (0..255)CRW
29GeneralBattery status1 Bit1.11 stateCRTU
30GeneralBus power cut over 30 days1 Bit1.2 booleanCRTU
31GeneralDate and time of bus power cut/return8 Bytes19.1 date timeCRTU
Parameters (87)
ParameterTypeDefault
Meter typelistVolume
TimestamplistWithout
Volume unitlistLiter
Volume pulse value (l)float 0.1…10001
Volume pulse value (m3)float 0.0001…1000.001
Energy unitlistWh
Energy pulse value (Wh)unsignedInt 1…1000100
Energy pulse value (kWh)unsignedInt 1…1001
Emission on bus every x pulseunsignedInt 1…655351
Volume meter: preset value (l)float 0…21474836470
Volume meter: preset value (m3)float 0…21474836470
Total counter preset (m3)float 0…21474836470
Energy meter: preset value (Wh)unsignedInt 0…42949672950
Energy meter: preset value (kWh)unsignedInt 0…42949672950
Total counter preset (Wh)unsignedInt 0…42949672950
Energy meter: preset value tariff 0 (Wh)unsignedInt 0…42949672950
Energy meter: preset value tariff 0 (kWh)unsignedInt 0…42949672950
Total counter preset Tariff 0 (Wh)unsignedInt 0…42949672950
Energy meter: preset value tariff 1 (Wh)unsignedInt 0…42949672950
Energy meter: preset value tariff 1 (kWh)unsignedInt 0…42949672950
Total energy counter preset Tariff 1 (Wh)unsignedInt 0…42949672950
Energy meter: preset value tariff 2 (Wh)unsignedInt 0…42949672950
Energy meter: preset value tariff 2 (kWh)unsignedInt 0…42949672950
Total counter preset Tariff 2 (Wh)unsignedInt 0…42949672950
Energy meter: preset value tariff 3 (Wh)unsignedInt 0…42949672950
Energy meter: preset value tariff 3 (kWh)unsignedInt 0…42949672950
Total counter preset Tariff 3 (Wh)unsignedInt 0…42949672950
Energy meter: preset value tariff 4 (Wh)unsignedInt 0…42949672950
Energy meter: preset value tariff 4 (kWh)unsignedInt 0…42949672950
Total counter preset Tariff 4 (Wh)unsignedInt 0…42949672950
Energy meter: preset value tariff 5 (Wh)unsignedInt 0…42949672950
Energy meter: preset value tariff 5 (kWh)unsignedInt 0…42949672950
Total counter preset Tariff 5 (Wh)unsignedInt 0…42949672950
Energy meter: preset value tariff 6 (Wh)unsignedInt 0…42949672950
Energy meter: preset value tariff 6 (kWh)unsignedInt 0…42949672950
Total counter preset Tariff 6 (Wh)unsignedInt 0…42949672950
Energy meter: preset value tariff 7 (Wh)unsignedInt 0…42949672950
Energy meter: preset value tariff 7 (kWh)unsignedInt 0…42949672950
Total counter preset Tariff 7 (Wh)unsignedInt 0…42949672950
Energy meter: preset value tariff 8 (Wh)unsignedInt 0…42949672950
Energy meter: preset value tariff 8 (kWh)unsignedInt 0…42949672950
Total counter preset Tariff 8 (Wh)unsignedInt 0…42949672950
Energy meter: preset value tariff 9 (Wh)unsignedInt 0…42949672950
Energy meter: preset value tariff 9 (kWh)unsignedInt 0…42949672950
Total counter preset Tariff 9 (Wh)unsignedInt 0…42949672950
Energy meter: preset value tariff 10 (Wh)unsignedInt 0…42949672950
Energy meter: preset value tariff 10 (kWh)unsignedInt 0…42949672950
Total counter preset Tariff 10 (Wh)unsignedInt 0…42949672950
Total energy emission modelistOn change and periodically
Total volume emission modelistOn change and periodically
Emission total volume by variation of (l)float 0.1…214748364710
Emission total volume by variation of (m3)float 0.0001…21474836470.01
Total counter on change value (m3)float 0.0001…21474836470.01
Emission total energy by variation of (kWh)unsignedInt 1…42949672951
Emission total energy by variation of (Wh)unsignedInt 1…4294967295100
Total counter on change value (Wh)unsignedInt 1…4294967295100
Emission of total energy everylist2 min 30 s
Emission of total volume everylist2 min 30 s
Partial energy emission modelistOn change and periodically
Partial volume emission modelistOn change and periodically
Emission partial volume by variation of (m3)float 0.0001…21474836470.01
Partial counter On change value (m3)float 0.0001…21474836470.01
Emission partial energy by variation of (kWh)unsignedInt 1…42949672951
Emission partial energy by variation of (Wh)unsignedInt 1…4294967295100
Partial counter On change value (Wh)unsignedInt 1…4294967295100
Emission of partial energy everylist2 min 30 s
Emission of partial volume everylist2 min 30 s
Emission partial volume by variation of (l)float 0.1…214748364710
Flow rate emission modelistOn change and periodically
Power emission modelistOn change and periodically
Emission of flow rate by variation of (l/h)float 0.1…214748364710
Emission of flow rate by variation of (m3/h)float 0.0001…21474836470.01
Flow rate On Change Value (m3/s)float 2.5e-8…21474836470.000002777777777777778
Emission of power by variation of (W)float 1…2147483647500
Emission of power by variation of (kW)float 0.001…21474836471
Power On change value (W)float 1…2147483647500
Emission of flow rate everylist2 min 30 s
Emission of power everylist2 min 30 s
Dynamic mode durationlist15 min
Emission of flow rate (dynamic mode) by variation of (l/h)float 0.1…21474836475
Emission of flow rate (dynamic mode) by variation of (m3/h)float 0.0001…21474836470.005
Dynamic mode Flow rate On change value (m3/s)float 0…21474836470.000001388888888888889
Emission of power (dynamic mode) by variation of (W)float 1…214748364710
Emission of power (dynamic mode) by variation of (kW)float 0.001…21474836470.01
Dynamic mode Power On change value (W)float 0.0001…214748364710
Application software versiontext1.0.13
Version of translation filetext0.0.3

Version history

ApplicationApp noFingerprintFirst seenSizeFile
STXE771 1.0 latest$E0BFBA362026-11-2589 KBDownload

About this file

This is the official ETS product database for the Hager Electro KNX pulse gateway 1 channel (TXE771), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Hager Electro